MAXIM GORKI THEATER BERLIN Am Festungsgraben 2, 10117 Berlin Technische Direktion Tel. 030.20221-336, Fax 030.20221-333 [email protected]1 Revision: June 2020 E. Arnaud Technical Documentation – Main Stage Download: http://www.gorki.de/en/technical-information Table of contents 1 Contact list ....................................................................................................................................... 2 1.1 Technical departments ............................................................................................................ 2 1.2 Theatre workshops .................................................................................................................. 2 1.3 Rehearsal stages ...................................................................................................................... 2 2 Views ............................................................................................................................................... 3 3 Measurements and technical specification for the stage ............................................................... 7 3.1 Relevant dimensions for scenery parts ................................................................................... 7 3.2 Stage dimensions..................................................................................................................... 7 3.3 Portal dimensions .................................................................................................................... 8 3.4 Fly galleries .............................................................................................................................. 8 3.5 Forestage / Proscenium........................................................................................................... 9 3.6 Understage machinery ............................................................................................................ 9 3.7 Overstage machinery / Fly system ........................................................................................ 10 3.8 Projection screens ................................................................................................................. 12 3.9 Auditorium ............................................................................................................................ 12 4 Lighting .......................................................................................................................................... 14 4.1 Fixed installation ................................................................................................................... 14 4.2 Stage lighting: Standard setup .............................................................................................. 15 4.3 Mobile lighting equipment .................................................................................................... 18 5 Sound ............................................................................................................................................. 20 6 Video.............................................................................................................................................. 21 7 Props .............................................................................................................................................. 22 7.1 Fog machines ......................................................................................................................... 22 7.2 Music instruments ................................................................................................................. 22 8 Dresser and Make up .................................................................................................................... 23
23
Embed
Technical Documentation Main Stage€¦ · Selda Hamdemir, Adviser to the Tech. Director-339 Etienne Arnaud , Assistant to the Tech. Director -336 Fax -333 Email [email protected]
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
MAXIM GORKI THEATER BERLIN Am Festungsgraben 2, 10117 Berlin Technische Direktion Tel. 030.20221-336, Fax 030.20221-333 [email protected]
1 Contact list ....................................................................................................................................... 2
6 Video .............................................................................................................................................. 21
MAXIM GORKI THEATER BERLIN Am Festungsgraben 2, 10117 Berlin Technische Direktion Tel. 030.20221-336, Fax 030.20221-333 [email protected]
2
Revision: June 2020
1 Contact list
1.1 Technical departments
Main number: +49 30 20221 -0
Technical Direction
Thomas Kirsten, Technical Director -337 Joachim Hering, Deputy Technical Director -470 Cornelia Fabian, Office Manager -335 Selda Hamdemir, Adviser to the Tech. Director -339 Etienne Arnaud, Assistant to the Tech. Director -336 Fax -333 Email [email protected]
Stage design Alissa Kolbusch, Head of Department -326 Assistant stage designers -328
Stage machinery Robert Rammelt, Deputy Technical Director, Tech. Production Manager, Head of Machinery
-330
Lighting Pierre Stolper, Head of Department -317 Sound & Video Christopher v. Nathusius, Head of Department -334
Props Jens Gebhardt, Head of Department -329 Make up Paula Karer, Head of Department -363 Dresser Andrea Schulz, Head of Department -227
1.2 Theatre workshops
Workshops Marcus Trettau, Head of Department -601 Peter Mayer, Deputy Head of Department -602 Fax -603
MAXIM GORKI THEATER BERLIN Am Festungsgraben 2, 10117 Berlin Technische Direktion Tel. 030.20221-336, Fax 030.20221-333 [email protected]
18
Revision: June 2020
4.3 Mobile lighting equipment
type amount kW info PC / Fresnel
prismatic lens ADB 6 0,65 barn door PC 2 1 barn door PC 2 2 barn door Fresnel ADB 5 2 barn door Fresnel Niethammer 3 2 barn door Fresnel Strand Lighting Pollux 2 5 barn door Fresnel HMI Arri 4 1,2 electrical shutter, barn door
VIDEO via SDI BLACKMAGIC VIDEOHUB 72 routing matrix various junction boxes in stage area (SDI, CAT) further junction boxes close to stage area (audience, foyers,
Cameras 2x Canon XF205 1x Teradek 300 HDMI wireless transmission 2x Panasonic AW130 HE PTZ remote camera
Surtitles
Separate surtitling system with Powerpoint or Spectitular 2 surtitling surfaces left/right of decorative portal 2x fixed Sanyo PLC XM150
(6000 Lumen, XGA, 4,7-7,2:1)
List of available screens: see paragraph 3.8.
MAXIM GORKI THEATER BERLIN Am Festungsgraben 2, 10117 Berlin Technische Direktion Tel. 030.20221-336, Fax 030.20221-333 [email protected]
22
Revision: June 2020
7 Props
7.1 Fog machines
Fog machines type output amount info
Base Classic 1300W 2 liquid-vaporizing fog machine Hazebase Highpower 2600W 2 liquid-vaporizing fog machine Power Tiny Battery 400W 3 liquid-vaporizing fog machine Tiny S Battery - 1 liquid-vaporizing fog machine Cryo-Fog 2300W 1 CO2 ("low lying" fog)
CO2 order is necessary Pea Souper dry ice - 1 Dry ice fog machine
Dry ice order is necessary
7.2 Music instruments
The props department possesses a number of various musical instruments, which are
often used in our own productions. We can send you a list of the musical instruments,
but please check availability with the props department.
There are also several upright pianos and a grand piano "August Förster 190" in the
house. The availability depends on our playing schedule and must be discussed in
advance.
MAXIM GORKI THEATER BERLIN Am Festungsgraben 2, 10117 Berlin Technische Direktion Tel. 030.20221-336, Fax 030.20221-333 [email protected]
23
Revision: June 2020
8 Dresser and Make up
Location: The wardrobes are above the stage area on second, third and fourth floor