Technical details -V-VAC Description Rated voltage Rated Frequency Rated busbar current Short time with stand current (3sec.) Insulation levels Width x Depth x Height Weight with circuit breaker (Appr.) Unit KV Hz A kA kAP KV/rms/KVp mm Kg Rating 36 50 up to 1600 26.3 66 70/170 1100X2370X2530 1300 Technical details -V-MAX circuit breaker Description Rated voltage Insulation Levels Normal current (40°C amb.) Breaking Capacity Making Capacity Short time withstand current Opening time Arcing time Total Break Time Making time Operating Sequence Weight Unit KV KVrms/kVp A kA kAP kA (3sec) ms ms ms ms - kg Rating 36 70/170 1250 31.5 80 31.5 60 (Max) 15 (Max) 75 (Max) 80 (Max) O-0. 3sec-CO-3min--CO 300 E-63, M.I.D.C., Ambad, Nashik - 422 010. INDIA TEL. : 0091- 253 - 6699841 / 835 WEBSITE : vibhacorporation.com E-MAIL : marketing@vibhacorporation.com / vibhaexport@yahoo.co.in Air Insulated Indoor Switchgear Cubical type V-VAC 36 with Vacuum Circuit Breaker type Vd4
3

Technical details -V-VAC Air Insulated Indoor Switchgear ... · PDF fileSalient Features - VD4 circuit breaker • The Vd4 circuit breaker is designed and type tested to meet requirements

Mar 12, 2018

Download

Documents

lyhanh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Technical details -V-VAC Air Insulated Indoor Switchgear ... · PDF fileSalient Features - VD4 circuit breaker • The Vd4 circuit breaker is designed and type tested to meet requirements

Technical details -V-VAC

Description

Rated voltage

Rated Frequency

Rated busbar current

Short time with stand current (3sec.)

Insulation levels

Width x Depth x Height

Weight with circuit breaker (Appr.)

Unit

KV

Hz

A

kA

kAP

KV/rms/KVp

mm

Kg

Rating

36

50

up to 1600

26.3

66

70/170

1100X2370X2530

1300

Technical details -V-MAX circuit breaker

Description

Rated voltage

Insulation Levels

Normal current (40°C amb.)

Breaking Capacity

Making Capacity

Short time withstand current

Opening time

Arcing time

Total Break Time

Making time

Operating Sequence

Weight

Unit

KV

KVrms/kVp

A

kA

kAP

kA (3sec)

ms

ms

ms

ms

-

kg

Rating

36

70/170

1250

31.5

80

31.5

60 (Max)

15 (Max)

75 (Max)

80 (Max)

O-0. 3sec-CO-3min--CO

300

E-63, M.I.D.C., Ambad, Nashik - 422 010. INDIA TEL. : 0091- 253 - 6699841 / 835WEBSITE : vibhacorporation.com E-MAIL : [email protected] / [email protected]

Air Insulated Indoor Switchgear Cubical type V-VAC 36with Vacuum Circuit Breaker type Vd4

Page 2: Technical details -V-VAC Air Insulated Indoor Switchgear ... · PDF fileSalient Features - VD4 circuit breaker • The Vd4 circuit breaker is designed and type tested to meet requirements

Salient Features - V-VAC 36

• The V-VAC 36 is designed and type tested to meet the requirements of IEC62271-200&60694/ IS :3427

• Metal clad compartmentalized construction - all compartments are segregated from each other with metal sheets

• IP4X degree of protection externally & IP6X available as an option

• Independent exhaust vents for all HT compartments

• Small width panel - 1100mm up to 2000A busbar rating

• The normal service performance are guaranteed under the following condition

- Min. Ambient Temp : -5°C- Max. Ambient Temp : - +40°C- Max. relative Humidity : 95%

• Metering compartment with numercal / static / electromagnetic relays, indicating meters, Lamps and control switches

• Protection and measuring apparatus customized as per requirement

• Cassette mounted breaker placed on elevated level with test position of breaker behind closed door

• Interlocks : - Racking in/out of breaker from test to service position and vice-versa with cubical door closed - To prevent racking in/out of breaker, when breaker in closed position - To prevent door from opening when breaker is in service position (optional)

• Multiple guides for safe and enduring alignment of fixed and moving power contacts

• Live parts covered by automatic polycarbonate shutters when breaker is racked out

• Removable fuses mounted on the PT

• Withdrawable line PT provided in the breaker panel

• EPOXY ENCAPSULATED PT Fuses in PT Trolley

Salient Features - VD4 circuit breaker

• The Vd4 circuit breaker is designed and type tested to meet requirements of IEC62271- 100 / IS : 13118

• Vacuum used as insulation and arc interruption medium

• Operationally safe and reliable in a wide range of ambient temperatures -5 to 40°C

• Capable of interrupting small magnetising and capactive currents

• Vacuum interrupters assembled in epoxy enclosure with insulated contact arms

• Features of operating mechanism :

- O-C-O operation without recharging

- Closing spring charged by motor in

less than 15 seconds

- Electrical anti-pumping

- Provision for manual charging

- Synchronisation and fast auto

re-closure duty

• Standard accessories :

- Mechanical ON/OFF push button

- Spring charge/discharge indication

ABB VD4 Vacuum Circuit Breaker

Page 3: Technical details -V-VAC Air Insulated Indoor Switchgear ... · PDF fileSalient Features - VD4 circuit breaker • The Vd4 circuit breaker is designed and type tested to meet requirements