VG Technical Datasheets for micro-turbine applications. OIL-INJECTED ROTARY SCREW GAS COMPRESSORS AND TREATMENT SYSTEMS FOR DRY METHANE OR NATURAL GAS Capacity up to 3000Nm 3 /h Available discharge pressures from 5.5bar(g) to 6.6bar(g) Nominal power from 3.0 to 355kW By working in partnership with Adicomp to secure your future
6
Embed
Technical datasheets for micro turbines vg 2014 (en)
Technical datasheets for micro turbines vg 2014 (en)
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
VG Technical Datasheets for micro-turbine applications.
OIL-INJECTED ROTARY SCREW GAS COMPRESSORS AND TREATMENT SYSTEMS FOR DRY METHANE OR NATURAL GAS Capacity up to 3000Nm3/h Available discharge pressures from 5.5bar(g) to 6.6bar(g) Nominal power from 3.0 to 355kW
By working in partnership with Adicomp to secure your future
Standard version is suitable for classified zones 1&2, indoor (OF) or outdoor installation with silenced and weather proof (WS) and safety features in accordance with ATEX standards.
Ambient temperature °C -20/40 -20/40 -20/40 -20/40 -20/40 -20/40 -20/40
Discharge gas temperature (above ambient) °C 10/15 10/15 10/15 10/15 10/15 10/15 10/15
Residual Oil in Gas mg/m3 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Residual Oil in Gas (Fine Filtration Optional) mg/m3 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Noise level ±3% (WS) dB(A) 70 70 70 72 72 74 74
Power Supply (Voltage) V 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC MAIN ELECTRIC MOTOR DATA Nominal power (Ex nA) zone 2 kW 4.0 5.5 7.5 11 11 15 18.5
VG in accordance to ATEX95 or EN1127-1:2001 no-classified zones. (3.0kW-15kW)
2
www.adicomp.com
VG - Oil injected rotary screw gas compressors
Electric motors (Ex nA) anti-spark type are de-rated of 20% for safety reasons when they work under inverter in ATEX zone 2. In case of BGR104 German standards, electric main motors installed are normally rated and no-ATEX version.
Standard version is suitable for classified zones 1&2, indoor (OF) or outdoor installation with silenced and weather proof (WS) and safety features in accordance with ATEX standards.
VG in accordance to ATEX95 or EN1127-1:2001 no-class. zones. (18.5kW-75kW)
Ambient temperature °C -20/40 -20/40 -20/40 -20/40 -20/40 -20/40 -20/40
Discharge gas temperature (above ambient) °C 10/15 10/15 10/15 10/15 10/15 10/15 10/15
Residual Oil in Gas mg/m3 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Residual Oil in Gas (Fine Filtration Optional) mg/m3 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Noise level ±3% (WS) dB(A) 74 74 74 76 76 76 76
Power Supply (Voltage) V 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC MAIN ELECTRIC MOTOR DATA Nominal power (Ex nA) zone 2 kW 22 30 37 45 55 75 90
Electric motors (Ex nA) anti-spark type are de-rated of 20% for safety reasons when they work under inverter in ATEX zone 2. In case of BGR104 German standards, electric main motors installed are normally rated and no-ATEX version.
4
www.adicomp.com
VG in accordance to ATEX95 or EN1127-1:2001 no-class. zones. (90kW-315kW)
Ambient temperature °C -20/40 -20/40 -20/40 -20/40 -20/40 -20/40 -20/40
Discharge gas temperature (above ambient) °C 10/15 10/15 10/15 10/15 10/15 10/15 10/15
Residual Oil in Gas mg/m3 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Residual Oil in Gas (Fine Filtration Optional) mg/m3 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Noise level ±3% (WS) dB(A) 78 78 78 78 80 80 80
Power Supply (Voltage) V 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC MAIN ELECTRIC MOTOR DATA Nominal power (Ex nA) zone 2 kW 110 132 160 200 250 315 355
Degree of protection IP 55 55 55 55 55 55 55 DIMENSIONS
Dimensions cm 300 x 150 x 210
300 x 150 x 210
300 x 150 x 210
360 x 200 x 224
360 x 200 x 224
410 x 210 x 224
410 x 210 x 224
Connection In/Out RP/EN1092
DN150 - DN50
DN200 - DN80
DN200 - DN80
DN200 - DN80
DN250 - DN100
DN250 - DN100
DN300 - DN100
Noise level ±3% (OF) dB(A) 90 90 92 92 92 94 94
Nominal power (Ex de) zone 1 kW 90 110 132 160 200 250 315
Power absorbed kW 47.0 < 90.0 69.0 < 110.0
75.0 < 132.0
75.0 < 160.0
75.0 < 200.0
115.0 < 250.0
162.0 < 315.0
Screw block rotation speed Rpm 1160 < 2330
1800 < 2960
1800 < 3350 870 < 1943 870 < 2390 1390 <
2980 1775 < 3623
Standard version is suitable for classified zones 1&2, indoor (OF) or outdoor installation with silenced and weather proof (WS) and safety features in accordance with ATEX standards.
VG - Oil injected rotary screw gas compressors
Electric motors (Ex nA) anti-spark type are de-rated of 20% for safety reasons when they work under inverter in ATEX zone 2. In case of BGR104 German standards, electric main motors installed are normally rated and no-ATEX version.