Top Banner
Thermo Fisher Scientific TDS_PEEK.xlsm 7/11/2011 Thermo Fisher Scientific, Asheville, North Carolina Model Number Application Storage of General (non-flammable) Laboratory Materials Storage Volume 548 liters / 19.4 cu. ft., 400 Standard 2" Boxes Temperature Rating -50°C to -85°C @ 32 °C(90°F) Ambient Electrical Power Instrument Rated Current 9.0 FLA Building Supply Rating Power Plug/Power Cord Length Agency Listings Sound Pressure Level (dBA) <= 66 dBA Indoor/Outdoor Usage Indoor Use Only Application Environment Non-Corrosive, Non-Flammable, Non-Explosive, Good Air Ventilation, 15° C - 32° C (59° F - 90° F) Lifetime of Product Refrigeration Configuration Refrigeration System Industrial-Rated Two Stage Cascade System Compressor / Number 1 HP Hermetic Compressor for Low Temperature Application / 2 Condenser Type/Number Enhanced Finned-Tube and Forced-Air Cooled / 1 Expansion Device Capillary Tube On Both Cascade Stages Evaporator Type Cold Wall With Enhanced Heat Transfer Treatment Defrost Method Manual Defrost Refrigerant Charge/Flammability CFC/HCFC-Free Enviromentally Safe Refrigerant Mixtures / Non-Flammable in both stages Controller/Electrical System Configuration and Features Controller Level Power Switch Controller Type Microprocessor Control with Touch Screen Input and Display. Includes USB System Data Retreival Setpoint Security Compressor Safe Guard Control Sensor Single RTD (1000 ohm Platinum RTD) RS232/Remote Alarm Terminals Adjustable Warm/Cold Alarms Auto-Voltage Safeguard Buck/Boost System Dimensions and Construction Interior Dimensions (H x D x W) 1.30 x 0.72 x 0.59 m (51.2 x 28.3 x 23.1 in.) Exterior Dimensions (H x D x W) 1.98 x 0.96 x 0.82 m (78.0 x 37.6 x 32.4 in.) Insulation Perimeter Heater Silicone-Based High Performance Seal Gasket with Electrical Door Perimeter Heater Shelves / Capacity 3 or 4 Stainless Steel Shelves Adjustable In 1" Increments. Max. Cap. per Shelf: 73.4 kg (165 lbs.) All-Direction Casters Standard with Locks Ship Weight Approximately 332 kg (730 lbs.) Other Options Typical Performance Characteristics in 25 ° C Ambient C:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\400_PD_WU.jpg C:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\400_Cycle.jpg C:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\400_perf.jpg 1) Performance is nominal and individual units may vary. 2) Freezer performance will differ due to product amount, product size and operating conditions. 3) Continuous product enhancements may, without notice, result in amendments or ommisions to this specification. Thermo Scientific cannot accept responsibility for damage, injury, loss or expenses resulting from misapplication of the information herein. © 2011 Thermo Scientific Inc. All trademarks are the property of Thermo Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. LN2 or CO2 Back Up System, HID Controlled Access, SMS Text, Chart Recorder, 4 or 5 Inner Doors Fully Adjustable Yes High Temperature Warning/Current and Temperature Protection/Logic Protection RS485/4-20mA output High R-value Vacuum Insulation Panels and High Density Water-Blown Polyurethane Foam Specifications Thermo Scientific Revco UxF40086D 208V/230V, 60 Hz, 1 Phase On-Off with Circuit Breaker Technical Data Sheet Thermo Scientific Revco Ultra-Low Temperature Upright Freezer Revision-0 10 years Eye Level Application, Rating and Electrical Data UL, cUL NEMA 5-20P or IEC Cord, 10 Feet or 3.0 Meters 20.0A dedicated grounded circuit. Protected by circuit breaker rated for inductive loads
12

Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

Oct 31, 2019

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

Thermo Fisher Scientific TDS_PEEK.xlsm 7/11/2011

Thermo Fisher Scientific, Asheville, North Carolina

Model Number

Application Storage of General (non-flammable) Laboratory Materials Storage Volume 548 liters / 19.4 cu. ft., 400 Standard 2" Boxes

Temperature Rating -50°C to -85°C @ 32 °C(90°F) AmbientElectrical Power

Instrument Rated Current 9.0 FLABuilding Supply Rating

Power Plug/Power Cord LengthAgency Listings

Sound Pressure Level (dBA) <= 66 dBA Indoor/Outdoor Usage Indoor Use Only

Application Environment Non-Corrosive, Non-Flammable, Non-Explosive, Good Air Ventilation, 15° C - 32° C (59° F - 90° F)Lifetime of Product

Refrigeration ConfigurationRefrigeration System Industrial-Rated Two Stage Cascade SystemCompressor / Number 1 HP Hermetic Compressor for Low Temperature Application / 2

Condenser Type/Number Enhanced Finned-Tube and Forced-Air Cooled / 1Expansion Device Capillary Tube On Both Cascade StagesEvaporator Type Cold Wall With Enhanced Heat Transfer TreatmentDefrost Method Manual Defrost

Refrigerant Charge/Flammability CFC/HCFC-Free Enviromentally Safe Refrigerant Mixtures / Non-Flammable in both stagesController/Electrical System Configuration and Features

Controller LevelPower Switch

Controller Type Microprocessor Control with Touch Screen Input and Display. Includes USB System Data RetreivalSetpoint Security

Compressor Safe GuardControl Sensor Single RTD (1000 ohm Platinum RTD)

RS232/Remote Alarm TerminalsAdjustable Warm/Cold Alarms

Auto-Voltage Safeguard Buck/Boost System Dimensions and Construction

Interior Dimensions (H x D x W) 1.30 x 0.72 x 0.59 m (51.2 x 28.3 x 23.1 in.)Exterior Dimensions (H x D x W) 1.98 x 0.96 x 0.82 m (78.0 x 37.6 x 32.4 in.)

InsulationPerimeter Heater Silicone-Based High Performance Seal Gasket with Electrical Door Perimeter Heater

Shelves / Capacity 3 or 4 Stainless Steel Shelves Adjustable In 1" Increments. Max. Cap. per Shelf: 73.4 kg (165 lbs.)All-Direction Casters Standard with Locks

Ship Weight Approximately 332 kg (730 lbs.)Other Options

Typical Performance Characteristics in 25 ° C AmbientC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\400_PD_WU.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\400_Cycle.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\400_perf.jpg

1) Performance is nominal and individual units may vary. 2) Freezer performance will differ due to product amount, product size and operating conditions.3) Continuous product enhancements may, without notice, result in amendments or ommisions to this specification. Thermo Scientific cannot accept responsibility for damage, injury, loss or expenses resulting from misapplication of the information herein.

© 2011 Thermo Scientific Inc. All trademarks are the property of Thermo Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject

to change. Not all products are available in all countries. Please consult your local sales representative for details.

LN2 or CO2 Back Up System, HID Controlled Access, SMS Text, Chart Recorder, 4 or 5 Inner Doors

Fully Adjustable

YesHigh Temperature Warning/Current and Temperature Protection/Logic Protection

RS485/4-20mA output

High R-value Vacuum Insulation Panels and High Density Water-Blown Polyurethane Foam

SpecificationsThermo Scientific Revco UxF40086D

208V/230V, 60 Hz, 1 Phase

On-Off with Circuit Breaker

Technical Data SheetThermo Scientific Revco Ultra-Low Temperature Upright Freezer

Revision-0

10 years

Eye Level

Application, Rating and Electrical Data

UL, cULNEMA 5-20P or IEC Cord, 10 Feet or 3.0 Meters

20.0A dedicated grounded circuit. Protected by circuit breaker rated for inductive loads

Page 2: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

57.61463.2

18.2463.4

23.0584.1

19.9504.5

3.177.5

1.024.5

2.152.6

78.01981.3

17.2

SHELF WIDTH436.3

51.21301.1

FRONT

USER INTERFACE

35.9911.2

36.2919.2

1.436.1

10.3262.1

10.3262.1

9.9251.2

10.3262.1

2.974.8

27.0

SHELF DEPTH686.6

10.4263.8

2.666.3

4X ADJUSTABLESHELVES(3X SHELVES OPTIONAL)

49.21248.8

11.5292.1

25.1638.0

FLOOR REFERENCE

SERIALCOMMUNICATION

POWER PLUG

BACK

REMOTE ALARMCONTACT

POWER SWITCH

1.0[25.4]ACCESS PORTS

.38.0

27.0686.1

37.6955.4

31.7806.3

51.1

DOOR OPEN @ 1801299.0

2.666.3

2.666.3

58.6

DOOR OPEN @901489.2

17.8

TANK WIDTH451.4

28.3718.8

SYMBOLS, DESIGNATIONS AND1.GENERAL DRAWING METHODSENGWI002ALL COMPONENTS SHOULD BE2.RoHS COMPLIANTBASIC DIMENSION TOLERANCE3.UNLESS OTHERWISE SPECIFIED:.X = 0.100"DUAL DIMENSION IS INCH OVER4.METRIC.

- 60347 2011-06-30 NEW RELEASEREV. ECN # DATE DESCRIPTION

REVISIONS

12 11 10

J

I

H

G

A

B

300

THE INFORMATION CONTAINED HEREIN IS THE PROPRIETARY DATA OF THERMO FISHER SCIENTIFIC. IT IS NOT TO BE

REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN

CONSENT OF THERMO FISHER SCIENTIFIC.DO NOT SCALE THIS DRAWING.

275 AIKEN ROADASHEVILLE, NC 28804

TITLE FREEZER UNIT

SIZE SHEET 1 OF 1

DWG. NO.3rd ANGLEPROJECTION

D12 SolidWorks 2007-10-25

C

D

E

F

3456789

K

L

M

13141516171819

M

L

K

F

E

D

C

B

A

G

H

I

J

19 18 17 16 15 14 13 9 8 7 6 5 4 3 2 1101112

ULT

315100G01

Page 3: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

Thermo Fisher Scientific TDS_PEEK.xlsm 7/11/2011

Thermo Fisher Scientific, Asheville, North Carolina

Model Number

Application Storage of General (non-flammable) Laboratory Materials Storage Volume 548 liters / 19.4 cu. ft., 400 Standard 2" Boxes

Temperature Rating -50°C to -85°C @ 32 °C(90°F) AmbientElectrical Power

Instrument Rated Current 9.0 FLABuilding Supply Rating

Power Plug/Power Cord LengthAgency Listings

Sound Pressure Level (dBA) <= 66 dBA Indoor/Outdoor Usage Indoor Use Only

Application Environment Non-Corrosive, Non-Flammable, Non-Explosive, Good Air Ventilation, 15° C - 32° C (59° F - 90° F)Lifetime of Product

Refrigeration ConfigurationRefrigeration System Industrial-Rated Two Stage Cascade SystemCompressor / Number 1 HP Hermetic Compressor for Low Temperature Application / 2

Condenser Type/Number Enhanced Finned-Tube and Forced-Air Cooled / 1Expansion Device Capillary Tube On Both Cascade StagesEvaporator Type Cold Wall With Enhanced Heat Transfer TreatmentDefrost Method Manual Defrost

Refrigerant Charge/Flammability CFC/HCFC-Free Enviromentally Safe Refrigerant Mixtures / Non-Flammable in both stagesController/Electrical System Configuration and Features

Controller LevelPower Switch

Controller Type Microprocessor Control with Touch Screen Input and Display. Includes USB System Data RetreivalSetpoint Security

Compressor Safe GuardControl Sensor Single RTD (1000 ohm Platinum RTD)

RS232/Remote Alarm TerminalsAdjustable Warm/Cold Alarms

Auto-Voltage Safeguard Buck/Boost System Dimensions and Construction

Interior Dimensions (H x D x W) 1.30 x 0.72 x 0.59 m (51.2 x 28.3 x 23.1 in.)Exterior Dimensions (H x D x W) 1.98 x 0.96 x 0.82 m (78.0 x 37.6 x 32.4 in.)

InsulationPerimeter Heater Silicone-Based High Performance Seal Gasket with Electrical Door Perimeter Heater

Shelves / Capacity 3 or 4 Stainless Steel Shelves Adjustable In 1" Increments. Max. Cap. per Shelf: 73.4 kg (165 lbs.)All-Direction Casters Standard with Locks

Ship Weight Approximately 332 kg (730 lbs.)Other Options

Typical Performance Characteristics in 25 ° C AmbientC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\400_PD_WU.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\400_Cycle.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\400_perf.jpg

1) Performance is nominal and individual units may vary. 2) Freezer performance will differ due to product amount, product size and operating conditions.3) Continuous product enhancements may, without notice, result in amendments or ommisions to this specification. Thermo Scientific cannot accept responsibility for damage, injury, loss or expenses resulting from misapplication of the information herein.

© 2011 Thermo Scientific Inc. All trademarks are the property of Thermo Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject

to change. Not all products are available in all countries. Please consult your local sales representative for details.

LN2 or CO2 Back Up System, HID Controlled Access, SMS Text, Chart Recorder, 4 or 5 Inner Doors

Fully Adjustable

YesHigh Temperature Warning/Current and Temperature Protection/Logic Protection

RS485/4-20mA output

High R-value Vacuum Insulation Panels and High Density Water-Blown Polyurethane Foam

SpecificationsThermo Scientific Revco UxF40086D

208V/230V, 60 Hz, 1 Phase

On-Off with Circuit Breaker

Technical Data SheetThermo Scientific Revco Ultra-Low Temperature Upright Freezer

Revision-0

10 years

Eye Level

Application, Rating and Electrical Data

UL, cULNEMA 5-20P or IEC Cord, 10 Feet or 3.0 Meters

20.0A dedicated grounded circuit. Protected by circuit breaker rated for inductive loads

Page 4: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

19.9504.8

18.2463.4

57.61463.2

3.077.2

28.3720.0

1.024.5

78.01981.3

2.152.6

22.5

SHELF WIDTH572.1

51.21301.1

FRONT

FOR GRILLE SEEDETAIL VIEW

USER INTERFACE

WHITE BOARD

1.436.1

35.9911.036.2919.3

10.3262.1

10.3262.1

9.9251.2

10.3262.1

2.974.8

27.0

SHELF DEPTH686.6

2.666.3

10.4263.8 4X ADJUSTABLE

SHELVES(3X SHELVES OPTIONAL)

49.21250.8

11.5292.1

25.0636.0

FLOOR REFERENCE

SERIALCOMMUNICATION

POWER PLUGBACK

REMOTE ALARM CONTACT

POWER SWITCH

1.0[25.4]ACCESS PORTS

.38.2

37.6955.4

32.4821.9

31.7806.3

61.8

DOOR OPEN @1801570.6

2.666.3

64.0

DOOR OPEN @901626.2

28.3718.8

2.666.3

23.1

TANK WIDTH587.4

OPTIONAL CHART RECORDER

SYMBOLS, DESIGNATIONS AND1.GENERAL DRAWING METHODSENGWI002ALL COMPONENTS SHOULD BE2.RoHS COMPLIANTBASIC DIMENSION TOLERANCE3.UNLESS OTHERWISE SPECIFIED:.X = 0.100"DUAL DIMENSION IS INCH OVER4.METRIC.

DETAIL VIEW OF GRILLE

- 60347 2011-06-30 NEW RELEASEREV. ECN # DATE DESCRIPTION

REVISIONS

12 11 10

J

I

H

G

A

B

400

THE INFORMATION CONTAINED HEREIN IS THE PROPRIETARY DATA OF THERMO FISHER SCIENTIFIC. IT IS NOT TO BE

REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN

CONSENT OF THERMO FISHER SCIENTIFIC.DO NOT SCALE THIS DRAWING.

275 AIKEN ROADASHEVILLE, NC 28804

TITLE FREEZER UNIT

SIZE SHEET 1 OF 1

DWG. NO.3rd ANGLEPROJECTION

D12 SolidWorks 2007-10-25

C

D

E

F

3456789

K

L

M

13141516171819

M

L

K

F

E

D

C

B

A

G

H

I

J

19 18 17 16 15 14 13 9 8 7 6 5 4 3 2 1101112

ULT

315100G02

Page 5: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

Thermo Fisher Scientific TDS_PEEK.xlsm 7/11/2011

Thermo Fisher Scientific, Asheville, North Carolina

Model Number

Application Storage of General (non-flammable) Laboratory Materials Storage Volume 682 liters / 24.1 cu. ft., 500 Standard 2" Boxes

Temperature Rating -50°C to -85°C @ 32 °C(90°F) AmbientElectrical Power

Instrument Rated Current 9.0 FLABuilding Supply Rating

Power Plug/Power Cord LengthAgency Listings

Sound Pressure Level (dBA) <= 66 dBA Indoor/Outdoor Usage Indoor Use Only

Application Environment Non-Corrosive, Non-Flammable, Non-Explosive, Good Air Ventilation, 15° C - 32° C (59° F - 90° F)Lifetime of Product

Refrigeration ConfigurationRefrigeration System Industrial-Rated Two Stage Cascade SystemCompressor / Number 1 HP Hermetic Compressor for Low Temperature Application / 2

Condenser Type/Number Enhanced Finned-Tube and Forced-Air Cooled / 1Expansion Device Capillary Tube On Both Cascade StagesEvaporator Type Cold Wall With Enhanced Heat Transfer TreatmentDefrost Method Manual Defrost

Refrigerant Charge/Flammability CFC/HCFC-Free Enviromentally Safe Refrigerant Mixtures / Non-Flammable in both stagesController/Electrical System Configuration and Features

Controller LevelPower Switch

Controller Type Microprocessor Control with Touch Screen Input and Display. Includes USB System Data RetreivalSetpoint Security

Compressor Safe GuardControl Sensor Single RTD (1000 ohm Platinum RTD)

RS232/Remote Alarm TerminalsAdjustable Warm/Cold Alarms

Auto-Voltage Safeguard Buck/Boost System Dimensions and Construction

Interior Dimensions (H x D x W) 1.30 x 0.72 x 0.73 m (51.2 x 28.3 x 28.8 in.)Exterior Dimensions (H x D x W) 1.98 x 0.96 x 0.97 m (78.0 x 37.6 x 38.0 in.)

InsulationPerimeter Heater Silicone-Based High Performance Seal Gasket with Electrical Door Perimeter Heater

Shelves / Capacity 3 or 4 Stainless Steel Shelves Adjustable In 1" Increments. Max. Cap. per Shelf: 91.7 kg (205 lbs.)All-Direction Casters Standard with Locks

Ship Weight Approximately 355 kg (782 lbs.)Other Options

Typical Performance Characteristics in 25 ° C AmbientC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\500_PD_WU.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\500_Cycle.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\500_perf.jpg

1) Performance is nominal and individual units may vary. 2) Freezer performance will differ due to product amount, product size and operating conditions.3) Continuous product enhancements may, without notice, result in amendments or ommisions to this specification. Thermo Scientific cannot accept responsibility for damage, injury, loss or expenses resulting from misapplication of the information herein.

© 2011 Thermo Scientific Inc. All trademarks are the property of Thermo Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject

to change. Not all products are available in all countries. Please consult your local sales representative for details.

LN2 or CO2 Back Up System, HID Controlled Access, SMS Text, Chart Recorder, 4 or 5 Inner Doors

Fully Adjustable

YesHigh Temperature Warning/Current and Temperature Protection/Logic Protection

RS485/4-20mA output

High R-value Vacuum Insulation Panels and High Density Water-Blown Polyurethane Foam

SpecificationsThermo Scientific Revco UxF50086D

208V/230V, 60 Hz, 1 Phase

On-Off with Circuit Breaker

Technical Data SheetThermo Scientific Revco Ultra-Low Temperature Upright Freezer

Revision-0

10 years

Eye Level

Application, Rating and Electrical Data

UL, cULNEMA 5-20P or IEC Cord, 10 Feet or 3.0 Meters

20.0A dedicated grounded circuit. Protected by circuit breaker rated for inductive loads

Page 6: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

1.436.1

35.9911.2

36.2919.3

2.666.3

2.974.8

27.0

SHELF DEPTH686.6

9.9251.2

10.3262.1

10.3262.1

10.3262.1

10.4263.8

4X ADJUSTABLESHELVES

(3X SHELVES OPTIONAL)

49.21250.8

25.0636.0

11.5292.1

1.0[25.4]ACCESS PORTS

REMOTE ALARMCONTACTS

SERIALCOMMUNICATION

POWER SWITCH

POWER PLUG

2.152.6

18.2463.4

57.61463.0

34.0862.8

3.077.2

19.9504.6

1.024.5

28.2

SHELF WIDTH715.0

51.21301.2

78.01981.3

FRONT

USER INTERFACE

WHITE BOARD

FOR GRILLESEE DETAIL VIEW

.38.1

38.0964.8

37.6955.4

31.8808.1

73.1

DOOR OPEN @1801856.4

2.666.3

2.666.3

28.8

TANK WIDTH730.9

69.6

DOOR OPEN @901769.1

28.3718.8

OPTIONAL CHART RECORDER

BACK

FLOOR REFERENCE

GRILLE DETAIL VIEW

1.SYMBOLS, DESIGNATIONS AND GENERAL DRAWING METHODS ENGWI0022. ALL COMPONENTS SHOULD BE RoHS COMPLIANT3. BASIC DIMENSION TOLERANCE UNLESS OTHERWISE SPECIFIED: .X = 0.100" 4. DUAL DIMENSION IS INCH OVER METRIC.

- 60347 2011-06-30 NEW RELEASEREV. ECN # DATE DESCRIPTION

REVISIONS

12 11 10

J

I

H

G

A

B

500

THE INFORMATION CONTAINED HEREIN IS THE PROPRIETARY DATA OF THERMO FISHER SCIENTIFIC. IT IS NOT TO BE

REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN

CONSENT OF THERMO FISHER SCIENTIFIC.DO NOT SCALE THIS DRAWING.

275 AIKEN ROADASHEVILLE, NC 28804

TITLE FREEZER UNIT

SIZE SHEET 1 OF 1

DWG. NO.3rd ANGLEPROJECTION

D12 SolidWorks 2007-10-25

C

D

E

F

3456789

K

L

M

13141516171819

M

L

K

F

E

D

C

B

A

G

H

I

J

19 18 17 16 15 14 13 9 8 7 6 5 4 3 2 1101112

ULT

315100G03

Page 7: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

Thermo Fisher Scientific TDS_PEEK.xlsm 7/11/2011

Thermo Fisher Scientific, Asheville, North Carolina

Model Number

Application Storage of General (non-flammable) Laboratory Materials Storage Volume 682 liters / 24.1 cu. ft., 500 Standard 2" Boxes

Temperature Rating -50°C to -85°C @ 32 °C(90°F) AmbientElectrical Power

Instrument Rated Current 9.0 FLABuilding Supply Rating

Power Plug/Power Cord LengthAgency Listings

Sound Pressure Level (dBA) <= 66 dBA Indoor/Outdoor Usage Indoor Use Only

Application Environment Non-Corrosive, Non-Flammable, Non-Explosive, Good Air Ventilation, 15° C - 32° C (59° F - 90° F)Lifetime of Product

Refrigeration ConfigurationRefrigeration System Industrial-Rated Two Stage Cascade SystemCompressor / Number 1 HP Hermetic Compressor for Low Temperature Application / 2

Condenser Type/Number Enhanced Finned-Tube and Forced-Air Cooled / 1Expansion Device Capillary Tube On Both Cascade StagesEvaporator Type Cold Wall With Enhanced Heat Transfer TreatmentDefrost Method Manual Defrost

Refrigerant Charge/Flammability CFC/HCFC-Free Enviromentally Safe Refrigerant Mixtures / Non-Flammable in both stagesController/Electrical System Configuration and Features

Controller LevelPower Switch

Controller Type Microprocessor Control with Touch Screen Input and Display. Includes USB System Data RetreivalSetpoint Security

Compressor Safe GuardControl Sensor Single RTD (1000 ohm Platinum RTD)

RS232/Remote Alarm TerminalsAdjustable Warm/Cold Alarms

Auto-Voltage Safeguard Buck/Boost System Dimensions and Construction

Interior Dimensions (H x D x W) 1.30 x 0.72 x 0.73 m (51.2 x 28.3 x 28.8 in.)Exterior Dimensions (H x D x W) 1.98 x 0.96 x 0.97 m (78.0 x 37.6 x 38.0 in.)

InsulationPerimeter Heater Silicone-Based High Performance Seal Gasket with Electrical Door Perimeter Heater

Shelves / Capacity 3 or 4 Stainless Steel Shelves Adjustable In 1" Increments. Max. Cap. per Shelf: 91.7 kg (205 lbs.)All-Direction Casters Standard with Locks

Ship Weight Approximately 355 kg (782 lbs.)Other Options

Typical Performance Characteristics in 25 ° C AmbientC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\500_PD_WU.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\500_Cycle.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\500_perf.jpg

1) Performance is nominal and individual units may vary. 2) Freezer performance will differ due to product amount, product size and operating conditions.3) Continuous product enhancements may, without notice, result in amendments or ommisions to this specification. Thermo Scientific cannot accept responsibility for damage, injury, loss or expenses resulting from misapplication of the information herein.

© 2011 Thermo Scientific Inc. All trademarks are the property of Thermo Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject

to change. Not all products are available in all countries. Please consult your local sales representative for details.

LN2 or CO2 Back Up System, HID Controlled Access, SMS Text, Chart Recorder, 4 or 5 Inner Doors

Fully Adjustable

YesHigh Temperature Warning/Current and Temperature Protection/Logic Protection

RS485/4-20mA output

High R-value Vacuum Insulation Panels and High Density Water-Blown Polyurethane Foam

SpecificationsThermo Scientific Revco UxF50086D

208V/230V, 60 Hz, 1 Phase

On-Off with Circuit Breaker

Technical Data SheetThermo Scientific Revco Ultra-Low Temperature Upright Freezer

Revision-0

10 years

Eye Level

Application, Rating and Electrical Data

UL, cULNEMA 5-20P or IEC Cord, 10 Feet or 3.0 Meters

20.0A dedicated grounded circuit. Protected by circuit breaker rated for inductive loads

Page 8: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

1.436.1

35.9911.2

36.2919.3

2.666.3

2.974.8

27.0

SHELF DEPTH686.6

9.9251.2

10.3262.1

10.3262.1

10.3262.1

10.4263.8

4X ADJUSTABLESHELVES

(3X SHELVES OPTIONAL)

49.21250.8

25.0636.0

11.5292.1

1.0[25.4]ACCESS PORTS

REMOTE ALARMCONTACTS

SERIALCOMMUNICATION

POWER SWITCH

POWER PLUG

2.152.6

18.2463.4

57.61463.0

34.0862.8

3.077.2

19.9504.6

1.024.5

28.2

SHELF WIDTH715.0

51.21301.2

78.01981.3

FRONT

USER INTERFACE

WHITE BOARD

FOR GRILLESEE DETAIL VIEW

.38.1

38.0964.8

37.6955.4

31.8808.1

73.1

DOOR OPEN @1801856.4

2.666.3

2.666.3

28.8

TANK WIDTH730.9

69.6

DOOR OPEN @901769.1

28.3718.8

OPTIONAL CHART RECORDER

BACK

FLOOR REFERENCE

GRILLE DETAIL VIEW

1.SYMBOLS, DESIGNATIONS AND GENERAL DRAWING METHODS ENGWI0022. ALL COMPONENTS SHOULD BE RoHS COMPLIANT3. BASIC DIMENSION TOLERANCE UNLESS OTHERWISE SPECIFIED: .X = 0.100" 4. DUAL DIMENSION IS INCH OVER METRIC.

- 60347 2011-06-30 NEW RELEASEREV. ECN # DATE DESCRIPTION

REVISIONS

12 11 10

J

I

H

G

A

B

500

THE INFORMATION CONTAINED HEREIN IS THE PROPRIETARY DATA OF THERMO FISHER SCIENTIFIC. IT IS NOT TO BE

REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN

CONSENT OF THERMO FISHER SCIENTIFIC.DO NOT SCALE THIS DRAWING.

275 AIKEN ROADASHEVILLE, NC 28804

TITLE FREEZER UNIT

SIZE SHEET 1 OF 1

DWG. NO.3rd ANGLEPROJECTION

D12 SolidWorks 2007-10-25

C

D

E

F

3456789

K

L

M

13141516171819

M

L

K

F

E

D

C

B

A

G

H

I

J

19 18 17 16 15 14 13 9 8 7 6 5 4 3 2 1101112

ULT

315100G03

Page 9: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

Thermo Fisher Scientific TDS_PEEK.xlsm 7/11/2011

Thermo Fisher Scientific, Asheville, North Carolina

Model Number

Application Storage of General (non-flammable) Laboratory Materials Storage Volume 815 liters / 28.8 cu. ft., 600 Standard 2" Boxes

Temperature Rating -50°C to -85°C @ 32 °C(90°F) AmbientElectrical Power

Instrument Rated Current 9.0 FLABuilding Supply Rating

Power Plug/Power Cord LengthAgency Listings

Sound Pressure Level (dBA) <= 66 dBA Indoor/Outdoor Usage Indoor Use Only

Application Environment Non-Corrosive, Non-Flammable, Non-Explosive, Good Air Ventilation, 15° C - 32° C (59° F - 90° F)Lifetime of Product

Refrigeration ConfigurationRefrigeration System Industrial-Rated Two Stage Cascade SystemCompressor / Number 1 HP Hermetic Compressor for Low Temperature Application / 2

Condenser Type/Number Enhanced Finned-Tube and Forced-Air Cooled / 1Expansion Device Capillary Tube On Both Cascade StagesEvaporator Type Cold Wall With Enhanced Heat Transfer TreatmentDefrost Method Manual Defrost

Refrigerant Charge/Flammability CFC/HCFC-Free Enviromentally Safe Refrigerant Mixtures / Non-Flammable in both stagesController/Electrical System Configuration and Features

Controller LevelPower Switch

Controller Type Microprocessor Control with Touch Screen Input and Display. Includes USB System Data RetreivalSetpoint Security

Compressor Safe GuardControl Sensor Single RTD (1000 ohm Platinum RTD)

RS232/Remote Alarm TerminalsAdjustable Warm/Cold Alarms

Auto-Voltage Safeguard Buck/Boost System Dimensions and Construction

Interior Dimensions (H x D x W) 1.30 x 0.72 x 0.87 m (51.2 x 28.3 x 34.4 in.)Exterior Dimensions (H x D x W) 1.98 x 0.96 x 1.11 m (78.0 x 37.6 x 43.6 in.)

InsulationPerimeter Heater Silicone-Based High Performance Seal Gasket with Electrical Door Perimeter Heater

Shelves / Capacity 3 or 4 Stainless Steel Shelves Adjustable In 1" Increments. Max. Cap. per Shelf: 110 kg (245 lbs.)All-Direction Casters Standard with Locks

Ship Weight Approximately 388 kg (854 lbs.)Other Options

Typical Performance Characteristics in 25 ° C AmbientC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\600_PD_WU.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\600_Cycle.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\600_perf.jpg

1) Performance is nominal and individual units may vary. 2) Freezer performance will differ due to product amount, product size and operating conditions.3) Continuous product enhancements may, without notice, result in amendments or ommisions to this specification. Thermo Scientific cannot accept responsibility for damage, injury, loss or expenses resulting from misapplication of the information herein.

© 2011 Thermo Scientific Inc. All trademarks are the property of Thermo Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject

to change. Not all products are available in all countries. Please consult your local sales representative for details.

SpecificationsThermo Scientific Revco UxF60086D

208V/230V, 60 Hz, 1 Phase

On-Off with Circuit Breaker

Technical Data SheetThermo Scientific Revco Ultra-Low Temperature Upright Freezer

Revision-0

10 years

Eye Level

Application, Rating and Electrical Data

UL, cULNEMA 5-20P or IEC Cord, 10 Feet or 3.0 Meters

20.0A dedicated grounded circuit. Protected by circuit breaker rated for inductive loads

LN2 or CO2 Back Up System, HID Controlled Access, SMS Text, Chart Recorder, 4 or 5 Inner Doors

Fully Adjustable

YesHigh Temperature Warning/Current and Temperature Protection/Logic Protection

RS485/4-20mA output

High R-value Vacuum Insulation Panels and High Density Water-Blown Polyurethane Foam

Page 10: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

18.2463.4

57.61463.2

19.9504.6

3.077.2

39.61005.7

1.024.5

2.152.6

78.01981.3

33.8

SHELF WIDTH857.9

51.21301.2

FLOOR REFERENCE

USER INTERFACE

WHITE BOARD

FRONT

FOR GRILL SEEDETAIL VIEW

.38.0

43.61107.7

37.6955.4

1.436.1

36.2919.3

35.9911.2

2.974.8

27.0

SHELF DEPTH686.6 2.9

73.9

9.9251.2

10.3262.1

10.3262.1

10.3262.1

10.4263.8

4X ADJUSTABLESHELVES(3X SHELVESOPTIONAL)25.0

636.0

49.21250.8

2X 11.5292.9

ACCESS PORTS1.0[25.4]

POWER PLUG

POWER SWITCH

SERIALCOMMUNICATION

REMOTE ALARMCONTACTS

BACK

31.8808.1

84.3

DOOR OPEN @1802142.1

75.2

DOOR OPEN @901910.8

2.666.3

2.666.3

34.4

TANK WIDTH874.5

28.3718.8

OPTIONAL CHART RECORDER

GRILLE DETAIL VIEW

SYMBOLS, DESIGNATIONS 1.AND GENERAL DRAWING METHODS ENGWI002ALL COMPONENTS SHOULD 2.BE RoHS COMPLIANTDUAL DIMENSION IS INCH 3.OVER METRICBASIC DIMENSION 4.TOLERANCE UNLESS OTHERWISE SPECIFIED:.X = .100"

- 60347 2011-06-30 NEW RELEASEREV ECN# DATE DESCRIPTION

REVISIONS

12 11 10

J

I

H

G

A

B

600

THE INFORMATION CONTAINED HEREIN IS THE PROPRIETARY DATA OF THERMO FISHER SCIENTIFIC. IT IS NOT TO BE

REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN

CONSENT OF THERMO FISHER SCIENTIFIC.DO NOT SCALE THIS DRAWING.

275 AIKEN ROADASHEVILLE, NC 28804

TITLE FREEZER UNIT

SIZE SHEET 1 OF 1

DWG. NO.3rd ANGLEPROJECTION

D12 SolidWorks 2007-10-25

C

D

E

F

3456789

K

L

M

13141516171819

M

L

K

F

E

D

C

B

A

G

H

I

J

19 18 17 16 15 14 13 9 8 7 6 5 4 3 2 1101112

ULT

315100G04

Page 11: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

Thermo Fisher Scientific TDS_PEEK.xlsm 7/11/2011

Thermo Fisher Scientific, Asheville, North Carolina

Model Number

Application Storage of General (non-flammable) Laboratory Materials Storage Volume 949 liters / 33.5 cu. ft., 700 Standard 2" Boxes

Temperature Rating -50°C to -85°C @ 32 °C(90°F) AmbientElectrical Power

Instrument Rated Current 9.0 FLABuilding Supply Rating

Power Plug/Power Cord LengthAgency Listings

Sound Pressure Level (dBA) <= 66 dBA Indoor/Outdoor Usage Indoor Use Only

Application Environment Non-Corrosive, Non-Flammable, Non-Explosive, Good Air Ventilation, 15° C - 32° C (59° F - 90° F)Lifetime of Product

Refrigeration ConfigurationRefrigeration System Industrial-Rated Two Stage Cascade SystemCompressor / Number 1 HP Hermetic Compressor for Low Temperature Application / 2

Condenser Type/Number Enhanced Finned-Tube and Forced-Air Cooled / 1Expansion Device Capillary Tube On Both Cascade StagesEvaporator Type Cold Wall With Enhanced Heat Transfer TreatmentDefrost Method Manual Defrost

Refrigerant Charge/Flammability CFC/HCFC-Free Enviromentally Safe Refrigerant Mixtures / Non-Flammable in both stagesController/Electrical System Configuration and Features

Controller LevelPower Switch

Controller Type Microprocessor Control with Touch Screen Input and Display. Includes USB System Data RetreivalSetpoint Security

Compressor Safe GuardControl Sensor Single RTD (1000 ohm Platinum RTD)

RS232/Remote Alarm TerminalsAdjustable Warm/Cold Alarms

Auto-Voltage Safeguard Buck/Boost System Dimensions and Construction

Interior Dimensions (H x D x W) 1.30 x 0.72 x 1.02 m (51.2 x 28.3 x 40.0 in.)Exterior Dimensions (H x D x W) 1.98 x 0.96 x 1.25 m (78.0 x 37.6 x 49.2 in.)

InsulationPerimeter Heater Silicone-Based High Performance Seal Gasket with Electrical Door Perimeter Heater

Shelves / Capacity 3 or 4 Stainless Steel Shelves Adjustable In 1" Increments. Max. Cap. per Shelf: 128 kg (285 lbs.)All-Direction Casters Standard with Locks

Ship Weight Approximately 432 kg (951 lbs.)Other Options

Typical Performance Characteristics in 25 ° C AmbientC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\700_PD_WU.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\700_Cycle.jpgC:\Documents and Settings\karen.wisniewski\My Documents\ULT\Ranier\Technical Data Sheets\TDS\Pictures\700_perf.jpg

1) Performance is nominal and individual units may vary. 2) Freezer performance will differ due to product amount, product size and operating conditions.3) Continuous product enhancements may, without notice, result in amendments or ommisions to this specification. Thermo Scientific cannot accept responsibility for damage, injury, loss or expenses resulting from misapplication of the information herein.

© 2011 Thermo Scientific Inc. All trademarks are the property of Thermo Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject

to change. Not all products are available in all countries. Please consult your local sales representative for details.

SpecificationsThermo Scientific Revco UxF70086D

208V/230V, 60 Hz, 1 Phase

On-Off with Circuit Breaker

Technical Data SheetThermo Scientific Revco Ultra-Low Temperature Upright Freezer

Revision-0

10 years

Eye Level

Application, Rating and Electrical Data

ULNEMA 5-20P or IEC Cord, 10 Feet or 3.0 Meters

20.0A dedicated grounded circuit. Protected by circuit breaker rated for inductive loads

LN2 or CO2 Back Up System, HID Controlled Access, SMS Text, Chart Recorder, 4 or 5 Inner Doors

Fully Adjustable

YesHigh Temperature Warning/Current and Temperature Protection/Logic Protection

RS485/4-20mA output

High R-value Vacuum Insulation Panels and High Density Water-Blown Polyurethane Foam

Page 12: Technical Data Sheet Thermo Scientific Revco Ultra-Low ....pdf · Industrial-Rated Two Stage Cascade System. Compressor / Number . 1 HP Hermetic Compressor for Low Temperature Application

1.436.1

35.9911.2

36.2919.2

2.974.8

27.0

SHELF DEPTH686.6 2.6

66.3

9.9251.2

10.3262.1

10.3262.1

10.3262.1

10.4263.8

4X ADJUSTABLESHELVES

(3 SHELVES OPTIONAL)25.0

636.0

49.21250.8

11.5292.9

SERIAL COMMUNICATION

REMOTE ALARMCONTACTS

POWER PLUG

1.0[25.4]ACCESS PORTS

POWERSWITCH

45.21148.6

1.024.5

3.077.2

19.9505.0

18.2463.4

2.152.6

57.61463.2

2.666.3

51.21301.1

39.4

SHELF WIDTH1000.8

78.01981.3

FOR GRILLE SEE DETAIL VIEW

USER INTERFACE

WHITE BOARD

31.8808.1

95.6

DOOR OPEN @ 1802427.9

2.665.6

2.665.6

40.0

TANK WIDTH1016.0

80.9

DOOR OPEN @ 902054.8

28.3718.8

.38.0

49.21250.6

37.6955.4

OPTIONAL CHARTRECORDER

BACK

1.SYMBOLS, DESIGNATIONS AND GENERAL DRAWING METHODS ENGWI0022. ALL COMPONENTS SHOULD BE RoHS COMPLIANT3. BASIC DIMENSION TOLERANCE UNLESS OTHERWISE SPECIFIED: .X= 0.100" 4. DUAL DIMENSION IS INCH OVER METRIC.

GRILLE DETAIL VIEW

FLOOR REFERENCE

- 60347 2011-06-30 NEW RELEASEREV. ECN # DATE DESCRIPTION

REVISIONS

12 11 10

J

I

H

G

A

B

700

THE INFORMATION CONTAINED HEREIN IS THE PROPRIETARY DATA OF THERMO FISHER SCIENTIFIC. IT IS NOT TO BE

REPRODUCED OR DISCLOSED IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN

CONSENT OF THERMO FISHER SCIENTIFIC.DO NOT SCALE THIS DRAWING.

275 AIKEN ROADASHEVILLE, NC 28804

TITLE FREEZER UNIT

SIZE SHEET 1 OF 1

DWG. NO.3rd ANGLEPROJECTION

D12 SolidWorks 2007-10-25

C

D

E

F

3456789

K

L

M

13141516171819

M

L

K

F

E

D

C

B

A

G

H

I

J

19 18 17 16 15 14 13 9 8 7 6 5 4 3 2 1101112

ULT

315100G05