5 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Benefits
Motorized blinds and draperies were thought of as an indulgence available only to the elite several years
ago. But today’s hardware, technology and pricing have made this onetime luxury easily available to the
general public. Motorized blinds, shades and draperies offer many benefits for many people. Parents with
young children, the elderly and even just the average person will benefit from having motorized window
coverings, which eliminate the need to fuss with wands or cords. If you suffer from mobility or dexterity issues,
or are just tired of dealing with tangled cords, this investment can help your window coverings function
flawlessly and look spectacular
Motorization can be used for virtually any type of window treatment, from blinds to shades to drapery.
Even those high windows you can hardly reach enough to clean can suddenly have window treatments
you can operate with ease, thanks to motorization. As one of the most revolutionary trends in the industry,
motorized operating systems offer the convenience and luxury of controlling your window covers from the
comfort of your bed, sofa, and dining room table – anywhere you like. However, motorization is more than
just a convenience. It also offers increased energy efficiency and safety, a true win-win in many aspects. In
residential applications with just the click of a button, motorization allows you to raise and lower treatments,
adjust slats and vanes, rotate and move from side to side, all with the ease and simplicity of a battery
operated remote. Just point and press! However, you can even take it one step further, with hard-wired
technology, with a home automation system.
When your windows are very high, a motorized shade can help maximize functionality. I would recommend
that an installation like this be hardwired with either a remote or wall switch, so you can avoid having to get
the ladder out to change the batteries.
If you have a large window, the weight of one blind can sometimes be too heavy for one person to lift. This
is a perfect situation for a motorized blind.
Hard wired motorization enables you to control your window coverings through a switch on your wall, just
like a light switch, which fits seamlessly with any décor. You can program various positions for your window
treatments and still benefit from the use of an integrated remote. With hard wired motorization, you’ll enjoy
extreme accuracy and precision.
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
7 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux Rechargeable Battery Motor
Technical Specifications
Weight Capacity
Radio Frequency
Item Code: 6-700-CM-25E02
Motor Diameter: Series 25mm
Motor Length: 16 in
Functional Tubes: Keyed 1.5” (38mm) Tube
Limits: Electronic
Time of Operation: 4 Minutes
Power: DC 12V. Internal Battery Amps: 900m A. Output: 1 Nm | 30 RPM
Recommended use: Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...
Tube DiameTeR Nm: 1.0 RPm: 30
1.5” 44mm / 50mm / 55mm / 60mm / 65mm / 78mm /
kg lb kg lb kg lb kg lb kg lb kg lb kg lb
3.7 8.2 - - - - - - - -
Internal Rechargeable Battery
MODEL: 6-700-CM-25E02
ITEM CODE: 6-700-CM-25E02
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
9 Vertilux CELTIC II - Technical Catalogue
CELTIC II -
9
Battery System for Neolux Dual Shades and Roller Shades
Neolux Roller Shades with Rechargeable Battery Motor
5
3
4
6
2
8
1
7
3
5
Light Gap = LGMeasurement include adapters
0.75 ''
LG Motor
0.5 ''
LG End Plug *Measurements will vary depending on the fabric
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-25E02 Celtic II Battery Motor Internal Power 1 EA
20-149-12-CAVXX Rollux- Aluminum Cassette 120 * 1 EA
0-149-10-CAVXX Rollux- Aluminum Cassette 100 ** 1 EA
30-149-12-BR08I Rollux- Cassette 120 Bracket 2 EA
0-149-10-BR08I Vertilux- Cassette 100 Bracket 2 EA
4 0-149-08-E38WH Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White 1 EA
50-149-12-CO0XX Rollux- Cassette 120 End Cover *** 2 EA
0-149-10-CO0XX Rollux- Cassette 100 End Cover **** 2 EA
60-149-12-BRMWH Rollux- Cassette 120 Mounting Bracket White 3 EA
0-149-10-BRMWH Rollux- Cassette 100 Mounting Bracket 3 EA
7 6-200-60-70427 Motor Plate for 400 Series Motor 1 EA
8 0-154-TU-00038 Rollux 1 1/2” (38mm) Aluminum Tube with Tape 16’ Mill Finish ***** - -
9 6-700-CM-DC001 Celtic ll Charger for Battery Motor with Internal Battery 1 EA
***** Maximum recommended tube length is 7 FT.
Individual Components Itemized
84”
84”Maximum
Shade Size*
* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black.
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
11 Vertilux CELTIC II - Technical Catalogue
CELTIC II -
External Battery Wand
Vertilux Rechargeable Battery Motor with Solar Panel
Technical Specifications
Weight Capacity
Radio Frequency
Item Code: 6-700-CM-25E01
Motor Diameter: Series 25mm
Motor Length: 16 in
Functional Tubes: Keyed 1.5” (38mm) Tube
Limits: Electronic
Time of Operation: 4 Minutes
Power: DC 12V. Ext. Power: Battery Wand, Solar Panel Amps: 900m A. Output: 1 Nm | 30 RPM
Recommended use: Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...
Tube DiameTeR Nm: 1.0 RPm: 30
1.5” 44mm / 50mm / 55mm / 60mm / 65mm / 78mm /
kg lb kg lb kg lb kg lb kg lb kg lb kg lb
3.7 8.2 - - - - - - - -
MODEL: 6-700-CM-25E01
ITEM CODE: 6-700-CM-25E01
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
13 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Neolux & Roller Shade Battery System
5
3
4
6
2
8
9
1
7
3
5
Light Gap = LGMeasurement include adapters
0.75 ''
LG Motor
0.5 ''
LG End Plug *Measurements will vary depending on the fabric
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-25E01 Celtic II Battery Motor External Power 1 EA
20-149-12-CAVXX Rollux- Aluminum Cassette 120 * 1 EA
0-149-10-CAVXX Rollux- Aluminum Cassette 100 ** 1 EA
30-149-12-BR08I Rollux- Cassette 120 Bracket 2 EA
0-149-10-BR08I Vertilux- Cassette 100 Bracket 2 EA
4 0-149-08-E38WH Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White 1 EA
50-149-12-CO0XX Rollux- Cassette 120 End Cover *** 2 EA
0-149-10-CO0XX Rollux- Cassette 100 End Cover **** 2 EA
60-149-12-BRMWH Rollux- Cassette 120 Mounting Bracket White 3 EA
0-149-10-BRMWH Rollux- Cassette 100 Mounting Bracket 3 EA
7 6-200-60-70427 Motor Plate for 400 Series Motor 1 EA
8 0-154-TU-00038 Rollux 1 1/2” (38mm) Aluminum Tube with Tape 16’ Mill Finish ***** - -
9 6-700-01-BPOLE Battery Pole 2 EA
***** Maximum recommended tube length is 7 FT.
Individual Components Itemized
Battery System for Neolux Dual Shades and Roller Shades
84”
84”Maximum
Shade Size*
* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black.
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
15 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux Motor 35mm Series
Technical Specifications
Weight Capacity
Radio Frequency
Item Code: 6-700-CM-35E10
Motor Diameter: Series 35mm
Motor Length: 24 in
Functional Tubes: Round Smooth 40mm - 50mm
Limits: Electronic
Time of Operation: 4 Min
Power: AC 120V.50/60 Hz Amps: 0.96 A Output: 10 Nm | 15 RPM
Recommended use: Neolux Dual Shades and 2” Horizontal Blinds
Tube DiameTeR Nm: 6 RPm: 33
40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”
kg lb kg lb kg lb kg lb kg lb kg lb kg lb
15 33 13.63 30 12 26.4 - - - - - - - -
MODEL: 6-700-CM-35E10
ITEM CODE: 6-700-CM-35E10
16 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Neolux Dual Shade System
5
3
4
6
28
9
1
7
3
5Light Gap = LG
Measurement include adapters0.75 ''
LG Motor
0.5 ''
LG End Plug *Measurements will vary depending on the fabric
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-35R06 Celtic II 35MM RF Motor 120V/33 RPM / 6NM 1 EA
20-149-12-CAVXX Rollux- Aluminum Cassette 120 * 1 EA
0-149-10-CAVXX Rollux- Aluminum Cassette 100 ** 1 EA
30-149-12-BR08I Rollux- Cassette 120 Bracket 2 EA
0-149-10-BR08I Vertilux- Cassette 100 Bracket 2 EA
4 0-154-EW-CA038 Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White 1 EA
50-149-12-CO0XX Rollux- Cassette 120 End Cover *** 2 EA
0-149-10-CO0XX Rollux- Cassette 100 End Cover **** 2 EA
60-149-12-BRMWH Rollux- Cassette 120 Mounting Bracket White 3 EA
0-149-10-BRMWH Rollux- Cassette 100 Mounting Bracket 3 EA
7 6-200-60-70427 Motor Plate for 400 Series Motor 1 EA
8 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finished ***** - -
9 6-700-AS-35040 Celtic II Crown and Drive (40mm) mm 1 EA
***** Maximum recommended tube length is 10 FT.
Individual Components Itemized
System for Neolux Dual Shades and Roller Shades
108”
108”Maximum
Shade Size*
* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black.
17 Vertilux CELTIC II - Technical Catalogue
CELTIC II - 2” Horizontal Blinds System
4
8
9
6
6
7
6
32
6
5
4
3
1
*Measurements will vary depending on the fabric
* Quantities depend on size of shade. Substitute XXX by 700=Natural, 708=White Birch, 710=Bleach Wood, 722=Sugar Maple, 726=Golden Oak, 728=Cherry. ** Maximum recommended tube length is 10 FT.
System for Roman Shades and Wood Blinds
Individual Components Itemized
No. iTem No. DescRiPTioN QTy uNiT
1 0-074-50-WXXXH Louverlux - 2" Headrail * 192 FT BOX
2 0-098-CA-01100 Louverwood - 2" Center Support Bracket 1 EA
3 0-098-ES-XXXX 2" Inst. Brackets White Satin (Pair) 1 EA
4 6-200-60-80251 Motor/Idler Bkt for 2" Headrail (LS40) 2 EA
5 6-200-60-90186 40mm Octagonal End Cap 40/8 1 EA
6 6-200-61-80391 40mm CTS Kit (Cone CTS 40) 1 - EA
7 6-200-60-50521 40 mm Octagonal Tube ** - -
8 6-700-CM-35E10 Celtic II RF Electric Motor 120V/ 17rpm/ 35mm/ 10Nm 1 EA
9 6-700-AS-35OCT Celtic II Crown & Drive (Octagonal) for CM35 Motors 1 EA
120”
120”Maximum
Shade Size*
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
19 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux 35 mm Motor, 6 Nm, Mechanical Limits
Technical Specifications
Weight Capacity
Item Code: 6-700-CM-35R06
Motor Diameter: Series 35mm
Motor Length: 24 in
Functional Tubes: Round Smooth 40mm - 50mm
Limits: Mechanical
Time of Operation: 4 Min
Power: AC 120V.50/60 Hz Amps: 0.96 A Output: 6 Nm | 33 RPM
Recommended use: Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...
Tube DiameTeR Nm: 6 RPm: 33
40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”
kg lb kg lb kg lb kg lb kg lb kg lb kg lb
15 33 13.63 30 12 26.4 - - - - - - - -
Radio Frequency
MODEL: 6-700-CM-35R06
ITEM CODE: 6-700-CM-35R06
20 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Roller Shade System
Light Gap = LGMeasurement include adapters
0.5''
LG Motor
0.5''
LG End Plug *Measurements will vary depending on the fabric
Roller Shade System Components
120”
120”Maximum
Shade Size*
3 8
1
7
9
4
2
5
6
2
4
3
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-35R06 Celtic II 35MM RF Motor 120V/33 RPM / 6NM 1 EA
2 0-154-PB-00300 Celtic Universal Bracket (CUB) Small Female Bracket 2 EA
3 0-154-PC-001XX Celtic Universal Bracket (CUB) Small Bracket Cover * 2 EA
4 0-154-PC-003XX Celtic Universal Bracket (CUB) Small Bracket Screw Cover * 2 EA
50-154-PE-00501 Celtic Universal Bracket (CUB) 38mm End Plug - White 1 EA
0-154-PE-03301 Celtic Universal Bracket (CUB) 38mm End Plug - Black 1 EA
60-154-PS-00500 Celtic Universal Bracket (CUB) Snap-in End Support - White 1 EA
0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-in End Support - Black 1 EA
7 6-700-AS-35040 Celtic II Crown and Drive (40mm) for CM 35 Motors mm 1 EA
8 6-700-BR-SQ001 Installation 10mm Motor Block 1 EA
9 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finish ** - -
Individual Components Itemized
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 10 FT.
21 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Cassette Roller Shade System
5
3
4
6
28
9
1
7
3
5Light Gap = LG
Measurement include adapters0.75 ''
LG Motor
0.5 ''
LG End Plug *Measurements will vary depending on the fabric
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-35R06 Celtic II 35MM RF Motor 120V/33 RPM / 6NM 1 EA
20-149-12-CAVXX Rollux - Aluminum Cassette 120 * 1 EA
0-149-10-CAVXX Rollux - Aluminum Cassette 100 ** 1 EA
30-149-12-BR08I Rollux - Cassette 120 Bracket 2 EA
0-149-10-BR08I Vertilux - Cassette 100 Bracket 2 EA
4 0-154-EW-CA038 Rollux - Cassette 100/120 End Plug 1 1/2" (38mm) White 1 EA
50-149-12-CO0XX Rollux - Cassette 120 End Cover *** 2 EA
0-149-10-CO0XX Rollux - Cassette 100 End Cover **** 2 EA
60-149-12-BRMWH Rollux - Cassette 120 Mounting Bracket White 3 EA
0-149-10-BRMWH Rollux - Cassette 100 Mounting Bracket 3 EA
7 6-200-60-70427 Motor Plate for 400 Series Motor 1 EA
8 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finished ***** - -
9 6-700-AS-35040 Celtic II Crown and Drive (40mm) mm 1 EA
***** Maximum recommended tube length is 10 FT.
Individual Components Itemized
System for Neolux Dual Shades and Roller Shades
120”
120”Maximum
Shade Size*
* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black.
22 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Intermediate Double Motorized Roller Shade System, Mechanical Limits
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper.
Roller Shade System Components with Intermediate Bracket
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-35R06 Celtic II 35MM RF Motor 120V/33 RPM / 6NM 1 EA
2 0-154-AD-RA250 Rollux End Plug Adapter 2” (50mm) Tube 1 EA
3 0-154-PB-00300 Celtic Universal Bracket (CUB) Small Female Bracket 2 EA
4 0-154-PC-001XX Celtic Universal Bracket (CUB) Small Bracket Cover * 2 EA
5 0-154-PC-003XX Celtic Universal Bracket (CUB) Small Bracket Screw Cover * 2 EA
60-154-PE-00501 Celtic Universal Bracket (CUB) 38mm End Plug - White 1 EA
0-154-PE-03301 Celtic Universal Bracket (CUB) 38mm End Plug - Black 1 EA
70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-in End Support - White 1 EA
0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-in End Support - Black 1 EA
8 6-700-AS-35050 Celtic II Crown and Drive 50 mm 1 EA
9 6-700-BR-SQ001 Installation 10mm Motor Block 1 EA
10 6-700-AD-DL170 Celtic Drive (50mm) for VM35 Motors 2 EA
11 6-700-BR-DZ131 Center Support Bracket for 35mm Motors ** 1 EA
12 0-154-TU-3MM50 Rollux 3x50mm Alluminum Tube / no Tape ***
Individual Components Itemized
10
3
5
5
3
94
1
8
12
1112
67
4*Measurements will vary depending on the fabric
120”
120”Maximum
Shade Size*
*** Maximum recommended tube length is 10 FT.** The center support bracket reduces motor’s performance by approximately 15%
Light Gap = LGMeasurement include adapters
0.5''
LG Motor
0.5''
LG End Plug
23 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Motorized Roller Shade with Hook Mount (HM) System, Mechanical Limits
Light Gap = LGMeasurement include adapters
0.5”
LG Motor
0.5”
LG End Plug
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-35R06 Celtic II 35MM RF Motor 120V/33 RPM / 6NM 1 EA
2 0-155-BW-SL020 Universal Bracket 2” Hook SL-20 2 EA
3 0-155-EW-SLH53 Heavy Duty End Cap 38 mm Hook 1 EA
4 6-700-BR-4SLAM Rollux-CUB Motor Support Black for 35 Motors 1 EA
5 6-700-AS-35040 Celtic II Crown and Drive (40mm) for CM 35 Motors 1 EA
6 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finished * - -
* Maximum recommended tube length is 8 FT.
Individual Components Itemized
*Measurements will vary depending on the fabric
Roller Shade System Components
96”
118”Maximum
Shade Size*
4
31
5
6
2
2
4
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
25 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux 35 mm Motor, 6 Nm, Electronic limits
Technical Specifications
Weight Capacity
Radio Frequency
Item Code: 6-700-CM-35E06
Motor Diameter: Series 35mm
Motor Length: 24 in
Functional Tubes: Round Smooth 40mm - 50mm
Limits: Electronic
Time of Operation: 4 Min
Power: AC 120V.50/60 Hz Amps: 0.96 A Output: 6 Nm | 33 RPM
Recommended use: Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...
Tube DiameTeR Nm: 6 RPm: 33
40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”
kg lb kg lb kg lb kg lb kg lb kg lb kg lb
15 33 13.63 30 12 26.4 - - - - - - - -
ITEM CODE: 6-700-CM-35E06
MODEL: 6-700-CM-35E06
26 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Roller Shade System
Light Gap = LGMeasurement include adapters
0.5''
LG Motor
0.5''
LG End Plug*Measurements will vary depending on the fabric
Roller Shade System Components
120”
120”Maximum
Shade Size*
3 8
1
7
9
4
2
5
6
2
4
3
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-35E06 Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM 1 EA
2 0-154-PB-00300 Celtic Universal Bracket (CUB) Small Female Bracket 2 EA
3 0-154-PC-001XX Celtic Universal Bracket (CUB) Small Bracket Cover * 2 EA
4 0-154-PC-003XX Celtic Universal Bracket (CUB) Small Bracket Screw Cover * 2 EA
50-154-PE-00501 Celtic Universal Bracket (CUB) 38mm End Plug - White 1 EA
0-154-PE-03301 Celtic Universal Bracket (CUB) 38mm End Plug - Black 1 EA
60-154-PS-00500 Celtic Universal Bracket (CUB) Snap-in End Support - White 1 EA
0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-in End Support - Black 1 EA
7 6-700-AS-35040 Celtic II Crown and Drive (40mm) for CM 35 Motors mm 1 EA
8 6-700-BR-SQ001 Installation 10mm Motor Block 1 EA
9 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finish ** - -
Individual Components Itemized
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 10 FT.
27 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Cassette Roller Shade System
5
3
4
6
28
9
1
7
3
5Light Gap = LG
Measurement include adapters0.75 ''
LG Motor
0.5 ''
LG End Plug *Measurements will vary depending on the fabric
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-35E06 Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM 1 EA
20-149-12-CAVXX Rollux- Aluminum Cassette 120 * 1 EA
0-149-10-CAVXX Rollux- Aluminum Cassette 100 ** 1 EA
30-149-12-BR08I Rollux- Cassette 120 Bracket 2 EA
0-149-10-BR08I Vertilux- Cassette 100 Bracket 2 EA
4 0-154-EW-CA038 Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White 1 EA
50-149-12-CO0XX Rollux- Cassette 120 End Cover *** 2 EA
0-149-10-CO0XX Rollux- Cassette 100 End Cover **** 2 EA
60-149-12-BRMWH Rollux- Cassette 120 Mounting Bracket White 3 EA
0-149-10-BRMWH Rollux- Cassette 100 Mounting Bracket 3 EA
7 6-200-60-70427 Motor Plate for 400 Series Motor 1 EA
8 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finished ***** - -
9 6-700-AS-35040 Celtic II Crown and Drive (40mm) mm 1 EA
Individual Components Itemized
System for Neolux Dual Shades and Roller Shades
120”
120”Maximum
Shade Size*
***** Maximum recommended tube length is 10 FT.
* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black.
28 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Intermediate Double Motorized Roller Shade System, Electronic Limits
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper.
Roller Shade System Components with Intermediate Bracket
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-35E06 Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM 1 EA
2 0-154-AD-RA250 Rollux End Plug Adapter 2” (50mm) Tube 1 EA
3 0-154-PB-00300 Celtic Universal Bracket (CUB) Small Female Bracket 2 EA
4 0-154-PC-001XX Celtic Universal Bracket (CUB) Small Bracket Cover * 2 EA
5 0-154-PC-003XX Celtic Universal Bracket (CUB) Small Bracket Screw Cover * 2 EA
60-154-PE-00501 Celtic Universal Bracket (CUB) 38mm End Plug - White 1 EA
0-154-PE-03301 Celtic Universal Bracket (CUB) 38mm End Plug - Black 1 EA
70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-in End Support - White 1 EA
0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-in End Support - Black 1 EA
8 6-700-AS-35050 Celtic II Crown and Drive 50 mm 1 EA
9 6-700-BR-SQ001 Installation 10mm Motor Block 1 EA
10 6-700-AD-DL170 Celtic Drive (50mm) for VM35 Motors 2 EA
11 6-700-BR-DZ131 Center Support Bracket for 35mm Motors ** 1 EA
12 0-154-TU-3MM50 Rollux 3x50mm Alluminum Tube / no Tape *** - -
Individual Components Itemized
10
3
5
5
3
94
1
8
12
1112
67
4
Light Gap = LGMeasurement include adapters
0.5''
LG Motor
0.5''
LG End Plug*Measurements will vary depending on the fabric
120”
120”Maximum
Shade Size*
*** Maximum recommended tube length is 10 FT.** The center support bracket reduces motor’s performance by approximately 15%
29 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Motorized Roller Shade with Hook Mount (HM) System, Electronic Limits
Light Gap = LGMeasurement include adapters
0.5”
LG Motor
0.5”
LG End Plug
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-35E06 Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM 1 EA
2 0-155-BW-SL020 Universal Bracket 2” Hook SL-20 2 EA
3 0-155-EW-SLH53 Heavy Duty End Cap 38 mm Hook 1 EA
4 6-700-BR-4SLAM Celtic Universal Bracket (CUB) Motor Support Black for 35 Motors 1 EA
5 6-700-AS-35040 Celtic II Crown and Drive (40mm) for CM 35 Motors 1 EA
6 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finished * - -
* Maximum recommended tube length is 8 FT.
Individual Components Itemized
*Measurements will vary depending on the fabric
Roller Shade System Components
96”
118”Maximum
Shade Size*
4
31
5
6
2
2
4
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
31 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux Ultra Quiet Motor 45mm Series
Technical Specifications
Weight Capacity
Radio Frequency
Item Code: 6-700-RC-00001
Motor Diameter: Series 45mm
Motor Length: 30 in
Functional Tubes: Round Smooth 2” - 2 1/2” | 63mm
Limits: Mechanical
Time of Operation: 4 Min
Power: AC 120V.50/60 Hz Amps: 0.97 A Output: 4 Nm | 33 RPM
Recommended use: Roller Shades
Tube DiameTeR Nm: 4 RPm: 33
40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”
kg lb kg lb kg lb kg lb kg lb kg lb kg lb
- - - - 12 26 - - - - 9.53 21.16 - -
6-700-RC-00001
ITEM CODE: 6-700-RC-00001
32 Vertilux CELTIC II - Technical Catalogue
CELTIC II -
5
4
8
7
4
3
5
9
3
1
10
2
6
Ultra Quiet Motor, 4 Nm, for Single Roller Shade on 2” Tube
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-RC-00001 Celtic II RF Quiet Motor 120V / 33 rpm / 45 mm / 4 Nm 1 EA
2 0-154-AD-GA025 Rollux - Galaxy Adapter for 2.5" (63mm) Tube White 1 EA
3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA
4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA
5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA
60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA
0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA
70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA
0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA
8 6-700-AS-45063 Roller Crown & Drive Adaptor Set for 2.5" (63mm) Tube 1 EA
9 6-700-BR-SQ001 Installation 10mm Motor Block 1 EA
10 0-154-TU-3MM50 Rollux - 3x50mm Aluminum Tube / no Tape ** - -
System for Ultra Quiet Roller Shade
*Measurements will vary depending on the fabric
144”
144”Maximum
Shade Size*
Individual Components Itemized
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 12 FT.
Light Gap = LGMeasurement include adaptersLG Motor LG End Plug
w/o cover 0.5”w/cover 0.75”
w/o cover 0.5” w/cover 0.75”
33 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Ultra Quiet Motor, 4 Nm, for Single Roller Shade on 2.5” Tube
** Maximum recommended tube length is 19 FT.
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-RC-00001 Celtic II RF Quiet Motor 120V / 33 rpm / 45 mm / 4 Nm 1 EA
2 0-154-AD-GA025 Rollux - Galaxy Adapter for 2.5" (63mm) Tube White 1 EA
3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA
4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA
5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA
60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA
0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA
70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA
0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA
8 6-700-AS-45063 Roller Crown & Drive Adaptor Set for 2.5" (63mm) Tube 1 EA
9 6-700-BR-SQ001 Installation 10 mm Motor Block 1 EA
10 0-154-TU-00063 Rollux 2.5” 63 mm Alluminum Tube W/ Tape ** - -
System for Ultra Quiet Roller Shade
Light Gap = LGMeasurement include adaptersLG Motor LG End Plug *Measurements will vary depending on the fabric
144”
144”Maximum
Shade Size*
5
4
8
7
4
3
5
9
3
1
10
2
6
Individual Components Itemized
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper.
w/o cover 0.5” w/cover 0.75”
w/o cover 0.5”w/cover 0.75”
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
35 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux 20 Nm Motor for Large Roller Shade, Electronic Limits
Technical Specifications
Weight Capacity
Radio Frequency
Item Code: 6-700-CM-45E20
Motor Diameter: Series 45mm
Motor Length: 29 in
Functional Tubes: 2” Smooth - 2 1/2” | 70 & 78mm
Limits: Electronic
Time of Operation: 4 Min
Power: AC 120V.50/60 Hz Amps: 0.98 A Output: 20 Nm | 33 RPM
Recommended use: Oversize Roller Shades
Tube DiameTeR Nm: 20 RPm: 33
40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”
kg lb kg lb kg lb kg lb kg lb kg lb kg lb
- - - - 40 88 - - - - 33.3 73.3 30.5 67.2
6-700-CM-45E20
ITEM CODE: 6-700-CM-45E20
36 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Oversize Roller Shade System
53
4 91
810
2
6
7
3
5
4Light Gap = LG
Measurement include adaptersLG Motor LG End Plug *Measurements will vary depending on the fabric
Individual Components Itemized
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-45E20 Celtic II RF Electronic Motor 120V / 33 rpm / 45mm / 20Nm 1 EA
2 0-154-AD-RA250 Rollux-TM16&TM24 End Plug Adapter for 2"(50mm) Tube Vanilla 1 EA
3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA
4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA
5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA
60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA
0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA
70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA
0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA
8 6-700-AS-45050 Celtic II Drive (50mm) for CM45 1 EA
9 6-700-BR-CO45W Installation Clamp for Celtic II 1 EA
10 0-154-TU-3MM50 Rollux 3 x 50 mm Aluminum Tube / no Tape ** - -
144”
144”Maximum
Shade Size*
Oversize Roller Shade System Components
w/o cover 0.75” w/cover 1”
w/o cover 0.5”w/cover 0.75”
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 12 FT.
37 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Intermediate 20 Nm Motorized System for Oversized Roller Shades, Electronic Limits
Individual Components Itemized
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-45E20 Celtic II RF Electronic Motor 120V / 33 rpm / 45mm / 20Nm 1 EA
2 0-154-AD-RA250 Rollux-TM16&TM24 End Plug Adapter for 2"(50mm) 1 EA
3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA
4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA
5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA
60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA
0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA
70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA
0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA
8 6-700-AD-DL170 Celtic Drive (50mm) for VM35 Motors 2 EA
9 6-700-BR-CO45W Installation Clamp for Celtic II 45mm Motors - White motor 1 EA
10 6-700-BR-DZ131 Center Support Bracket VM35-45 Motors** 1 EA
11 0-154-TU-3MM50 Rollux 3X50 mm Aluminum Tube / no Tape *** - -
12 6-700-AS-45050 Celtic II Drive (50mm) for CM45 Motors 1 EA
4 35
91
12
11
8
26
7
10
113
5
4*Measurements will vary depending on the fabric
Oversize Roller Shade System Components
144”
118”Maximum
Shade Size*
Light Gap = LGMeasurement include adaptersLG Motor LG End Plug
w/o cover 0.75” w/cover 1”
w/o cover 0.5”w/cover 0.75”
*** Maximum recommended tube length is 12 FT With 2” Aluminum Tube** The center support bracket reduces motor’s performance by approximately 15% * Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper.
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
39 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux 20 Nm Motor for Large Roller Shade, Mechanical Limits
Technical Specifications
Weight Capacity
Radio Frequency
Item Code: 6-700-CM-45R20
Motor Diameter: Series 45mm
Motor Length: 29 in
Functional Tubes: 2” Smooth - 2 1/2” | 70 & 78mm
Limits: Mechanical
Time of Operation: 4 Min
Power: AC 120V.50/60 Hz Amps: 0.98 A Output: 20 Nm | 33 RPM
Recommended use: Oversize Roller Shades
Tube DiameTeR Nm: 20 RPm: 33
40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”
kg lb kg lb kg lb kg lb kg lb kg lb kg lb
- - - - 40 88 - - - - 33.3 73.3 30.5 67.2
6-700-CM-45R20
ITEM CODE: 6-700-CM-45R20
40 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Oversize Roller Shade System
53
4 91
810
2
6
7
3
5
4*Measurements will vary depending on the fabric
Individual Components Itemized
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-45R20 Celtic II RF Motor 120V / 33 rpm / 45mm / 20Nm 1 EA
2 0-154-AD-RA250 Rollux-TM16&TM24 End Plug Adapter for 2"(50mm) Tube Vanilla 1 EA
3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA
4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA
5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA
60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA
0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA
70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA
0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA
8 6-700-AS-45050 Celtic II Drive (50mm) for CM45 1 EA
9 6-700-BR-CO45W Installation Clamp for Celtic II 1 EA
10 0-154-TU-3MM50 Rollux 3 x 50 mm Aluminum Tube / no Tape ** - -
144”
144”Maximum
Shade Size*
Oversize Roller Shade System Components
Light Gap = LGMeasurement include adaptersLG Motor LG End Plug
w/o cover 0.75” w/cover 1”
w/o cover 0.5”w/cover 0.75”
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 12 FT.
41 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Intermediate 20 Nm Motorized System for Oversized Roller Shades, Mechanical Limits
Individual Components Itemized
*** Maximum recommended tube length is 12 FT With 2” Aluminum Tube** The center support bracket reduces motor’s performance by approximately 15%
4 35
91
12
11
8
26
7
10
113
5
4*Measurements will vary depending on the fabric
Oversize Roller Shade System Components
144”
118”Maximum
Shade Size*
Light Gap = LGMeasurement include adaptersLG Motor LG End Plug
w/o cover 0.75” w/cover 1”
w/o cover 0.5”w/cover 0.75”
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper.
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-CM-45R20 Celtic II RF Motor 120V / 33 rpm / 45mm / 20Nm 1 EA
2 0-154-AD-RA250 Rollux-TM16&TM24 End Plug Adapter for 2"(50mm) 1 EA
3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA
4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA
5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA
60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA
0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA
70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA
0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA
8 6-700-AD-DL170 Celtic Drive (50mm) for VM35 Motors 2 EA
9 6-700-BR-CO45W Installation Clamp for Celtic II 45mm Motors - White motor 1 EA
10 6-700-BR-DZ131 Center Support Bracket VM35-45 Motors** 1 EA
11 0-154-TU-3MM50 Rollux 3X50 mm Aluminum Tube / no Tape *** - -
12 6-700-AS-45050 Celtic II Drive (50mm) for CM45 Motors 1 EA
vert
ilux.
com
DASHTRACK
• Traverseupto165lbs.offabric
• Compactandlightweightforsimpleinstallation
• Simpleconnectivitytohome-automationsystems
• Directdriverubberbeltenablesquietoperation
• Harddrawtechnologyavoidsdamagetotheproduct
• DashTrackallowsdraperiestobeoperatedmanually,asafail safe during power outages
• Limitsaresetautomatically
• CompatiblewithallCelticIIControls
The one system for Drapery or Sliding PanelTrack motorization
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
45 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux Dashtrack, for Draperies and Sliding Panels
Technical Specifications
Radio Frequency
Item Number: 6-700-DM-00001
Weight: 165 lbs.
Motor Dimensions: 12.5 x 2.5 in
Limits: Automatic
Time of Operation: 4 Min
Power Transformer: 24V AMP: 2.7 A
Torque: 0.8 NM. RPM: 7.5 in/s
Recommended use: Drapery and Sliding Panels.
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
FOR PINCH PLEAD DRAPERIES
DASHTRACK
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
49 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux Dashtrack System
System for Pinch Plead Drapery
Individual Components Itemized
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-DM-00001 Vertilux Drapery Motor 1Nm/80rpm/24Vdc/65W 1 EA
2 6-700-DM-00002 Vertilux Drapery Motors - 24V Transformer 1 EA
3 6-700-DM-00003 Vertilux Drapery Motors - Main Control End 1 EA
4 6-700-DM-00004 Vertilux Drapery Motors - Secondary Control End 1 EA
5 6-700-DM-00005 Vertilux Drapery Motors - Interior Belt --- FT
6 6-700-DM-00006 Vertilux Drapery Motors - Pinch Plead Carriers --- EA
7 6-700-DM-00008 Vertilux Drapery Motors - Pinch Plead Master Carrier --- EA
8 6-700-DM-00009 Vertilux Drapery Motors - Curtain Track - White 19' --- FT
9 6-700-DM-00010 Vertilux Drapery Motors - Ceiling Clip --- EA
10 6-700-DM-00011 Vertilux Drapery Motors - Plastic Clip --- EA
11 0-030-CA-06600 Vertilux-Adj. "L" Bracket 85-145mm White --- EA
4
41
7
8
86
33
10
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
FOR RIPPLE FOLD DRAPERIES
DASHTRACK
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
53 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux Dashtrack System
System for Ripple Fold Drapery
Individual Components Itemized
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-DM-00001 Vertilux Drapery Motor 1Nm/80rpm/24Vdc/65W 1 EA
2 6-700-DM-00002 Vertilux Drapery Motors - 24V Transformer 1 EA
3 6-700-DM-00003 Vertilux Drapery Motors - Main Control End 1 EA
4 6-700-DM-00004 Vertilux Drapery Motors - Secondary Control End 1 EA
5 6-700-DM-00005 Vertilux Drapery Motors - Interior Belt --- FT
6
6-700-DM- Vertilux Drapery Motors - Ripple Fold Carriers 60% --- FT
6-700-DM-00014 Vertilux Drapery Motors - Ripple Fold Carriers 80% --- FT
6-700-DM-00015 Vertilux Drapery Motors - Ripple Fold Carriers 100% --- FT
6-700-DM-00016 Vertilux Drapery Motors - Ripple Fold Carriers 120% --- FT
7 6-700-DM-00018 Vertilux Drapery Motor - Ripple Fold Master Carrier set --- Set
8 6-700-DM-00009 Vertilux Drapery Motors - Curtain Track - White 19' --- FT
9 6-700-DM-00010 Vertilux Drapery Motors - Ceiling Clip --- EA
10 6-700-DM-00011 Vertilux Drapery Motors - Plastic Clip --- EA
11 0-030-CA-06600 Vertilux-Adj. "L" Bracket 85-145mm White --- EA
4
41
7
8
86
33
10
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
FOR SLIDING PANELS
DASHTRACK
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
57 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Vertilux Dashtrack System
System for Sliding Panel
Individual Components Itemized
No. iTem No. DescRiPTioN QTy uNiT
1 6-700-DM-00001 Vertilux Drapery Motor 1Nm/80rpm/24Vdc/65W 1 EA
2 6-700-DM-00002 Vertilux Drapery Motors - 24V Transformer 1 EA
3 6-700-DM-00003 Vertilux Drapery Motors - Main Control End 1 EA
4 6-700-DM-00004 Vertilux Drapery Motors - Secondary Control End 1 EA
5 6-700-DM-00005 Vertilux Drapery Motors - Interior Belt --- FT
6 6-700-DM-00008 Vertilux Drapery Motors - Pinch Plead Master Carrier --- EA
7 6-700-DM-00009 Vertilux Drapery Motors - Curtain Track - White 19' --- FT
8 6-700-DM-00010 Vertilux Drapery Motors - Ceiling Clip --- EA
9 6-700-DM-00011 Vertilux Drapery Motors - Plastic Clip --- EA
10 0-030-CA-06600 Vertilux-Adj. "L" Bracket 85-145mm White --- EA
4
41
7
8
86
33
10
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
FOR VERTILUX CELTIC II MOTORS
REMOTE CONTROLS
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
61 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Remote Controls for Vertilux Celtic II Motors
One Channel Remote
Six Channel Remote
Item No.: 6-700-AT-CRT01
Item No.: 6-700-AT-CRT06
Controls one single motor
Programs in less tan 10 seconds
Dimensions: 2” x 5”
Frequency: 433.92 Mhz
Distance 50’ with obstructions, 150’ line of site
Portable Control
Controls 5 Motors individually and the 6th Chanel controls all 5 motors simultaneously
Programs in less tan 10 seconds
Dimensions: 2” x 5”
Frequency: 433.92 Mhz
Distance 50’ with obstructions, 150’ line of site
Portable Control
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
63 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Remote Controls for Vertilux Celtic II Motors
Sixteen Channel Remote
Wireless 1 Channel Wall Switch
Item No.: 6-700-AT-CRT16
Item No.: 6-700-AT-CTW01
Controls 15 motors individually and the 16th chanel controls all 15 motors simultaneously
Programs in less tan 10 seconds
Dimensions: 2” x 5”
Frequency: 433.92 Mhz
Distance 50’ with obstructions, 150’ line of site
Portable Control
Controls one single motor
Programs in less tan 10 seconds
Dimensions: 3” x 5”
Frequency: 433.92 Mhz
Distance 50’ with obstructions, 150’ line of site
Wall Fixture Control
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
65 Vertilux CELTIC II - Technical Catalogue
CELTIC II - Remote for Vertilux Celtic II Motors
Wireless 6 Channel Wall Switch
Antenna RS232
Item No.: 6-700-AT-CTW06
Item No.: 6-700-AT-RS232
Controls 5 motors individually and the 6th chanel controls all 5 motors simultaneously
Programs in less tan 10 seconds
Dimensions: 3” x 5”
Frequency: 433.92 Mhz
Distance 50’ with obstructions, 150’ line of site
Wall Fixture Control
Home Automation Interface
Can daisy-chain (5) AC117-01 together
Multi-programmable operation
Dimensions: 8” x 6”
Frequency: 433.92 Mhz
Distance 100’ Radious
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
FRUSTATION FREE PROGRAMMING INSTRUCTIONS
REMOTE CONTROLS
Vert
ilux
ceLT
ic ii
- Te
chni
cal c
atal
ogue
CEL
TIC
II-
Rem
ote
Prog
ram
min
g
UP
DO
WN
PRO
GRA
M
CH
AN
NEL
UP
BATT
ERY
SCRE
W
TRA
NSM
ISO
R C
ELTI
C II
FRO
NT
VIEW
TRA
NSM
ISO
R C
ELTI
C II
BA
CK
VIE
W
CH
AN
NEL
DO
WN
STO
P
Vert
ilux
ceLT
ic ii
- Te
chni
cal c
atal
ogue
CEL
TIC
II-
Elec
troni
c Ba
ttery
Mot
or P
roga
mm
ing
Inst
ruct
ions
com
mo
N F
uN
cTi
oN
s
FuN
cTi
oN
PRo
GRa
mm
abL
e Fu
Nc
Tio
NsT
ePs
Nee
DeD
/ TR
aN
smiT
TeR
buTT
oN
sN
oTe
s
1C
omm
unic
ate
Tran
smitt
er
with
Mot
or
a) P
ress
the
PRO
GR
AM b
utto
n on
the
head
of t
he
m
otor
The
mot
or w
ill os
cilla
te
b) I
mm
edia
tely
pre
ss a
nd h
old
the
UP
butto
n
on
the
rem
ote
The
mot
or w
ill os
cilla
te a
gain
. At t
his
time
the
mot
or a
nd re
mot
e ha
ve
been
join
ed
2C
hang
e Di
rect
ion
of M
otor
a) T
o ch
ange
mot
or ro
tatio
n pr
ess
and
hold
the
S
TOP
butto
n on
the
rem
ote.
The
mot
or w
ill os
cilla
te
b) T
hen
pres
s an
d ho
ld th
e D
OW
N b
utto
n
on
the
rem
ote
The
mot
or w
ill os
cilla
te a
gain
c) V
erify
cor
rect
rota
tion
-
seTT
iNG
Lim
iTs
FuN
cTi
oN
PRo
GRa
mm
abLe
FuN
cTio
NsT
ePs
Nee
DeD
/ TR
aN
smiT
TeR
buTT
oN
sN
oTe
s
3Se
t UPP
ER L
imit
a) M
ove
the
shad
e 3
to 4
” bel
ow th
e up
per l
imit
p
ositi
on p
ress
the
PRO
GR
AM b
utto
n, L
ocat
ed o
n
the
back
of t
he re
mot
e
The
mot
or w
ill os
cilla
te T
his
will
put t
he m
otor
in P
RO
GR
AM m
ode
NO
TE: T
he fi
rst l
imit
(UPP
ER L
IMIT
) can
not b
e er
ased
b) N
ow m
ove
the
shad
e up
to th
e de
sire
d lo
catio
n
a
nd p
ress
the
PRO
GR
AM b
utto
n ag
ain
The
mot
or w
ill os
cilla
te. T
he u
pper
lim
it is
now
set
4Se
t LO
WER
Lim
it
a) M
ove
the
shad
e do
wn
away
from
the
uppe
r
lim
it pr
evio
usly
set
, pre
ss th
e PR
OG
RAM
but
ton
The
mot
or w
il os
cilla
te. T
his
will
put t
he m
otor
in P
RO
GR
AM m
ode
b) N
ow m
ove
the
shad
e up
to th
e de
sire
d lo
catio
n of
the
low
er li
mit
and
pres
s th
e PR
OG
RAM
but
ton
agai
nTh
e m
otor
will
osci
llate
. The
low
er li
mit
is n
ow s
et
You
mus
t fol
low
thes
e ins
truct
ions
in th
e sam
e ord
er th
ey a
ppea
r on
this
shee
t oth
erwi
se th
e com
man
ds w
ill n
ot b
e abl
e to
be d
one
Vert
ilux
ceLT
ic ii
- Te
chni
cal c
atal
ogue
CEL
TIC
II-
Elec
troni
c Ba
ttery
Mot
or P
roga
mm
ing
Inst
ruct
ions
seTT
iNG
iNTe
RmeD
iaTe
s Li
miT
s
FuN
cTi
oN
PRo
GRam
mab
Le Fu
NcTi
oN
sTeP
s N
eeD
eD /
TRa
Nsm
iTTe
R bu
TTo
Ns
No
Tes
5Se
tting
Inte
rmed
iate
s St
ops
(UP
to 5
)
a) M
ove
the
shad
e aw
ay fr
om th
e pr
evio
usly
set
li
mit,
abo
ut 6
inch
es, p
ress
the
PRO
GR
AM b
utto
nTh
e m
otor
will
osci
llate
b) N
ow m
ove
the
shad
e to
the
desi
red
loca
tion
of th
e
in
term
edia
te S
top
and
pres
s th
e PR
OG
RAM
but
ton
aga
inTh
e m
otor
will
osci
llate
. The
inte
rmed
iate
lim
it is
now
set
Less
co
mm
oN
Fu
Nc
Tio
Ns
PRo
GRa
mm
abL
e Fu
Nc
Tio
NsT
ePs
Nee
DeD
/ TR
aN
smiT
TeR
buTT
oN
sN
oTe
s
Eras
ing
limits
a) M
ove
the
shad
e to
the
limit
you
wis
h to
era
se. P
ress
an
d ho
ld th
e PR
OG
RAM
but
ton
for a
ppro
xim
atel
y 7
seco
nds
The
mot
or w
ill os
cilla
te tw
ice,
at t
his
time
the
limit
has
been
era
sed
Con
nect
an
extra
Tra
smitt
er
a) P
ress
and
hol
d th
e ST
OP
butto
n on
the
Rem
ote
a
lread
y pr
ogra
med
for a
ppro
xim
atel
y 5
seco
nd
The
mot
or w
ill os
cilla
te
b) Im
med
iate
ly p
ress
the
UP
butto
n on
the
rem
ote
y
ou w
ish
to a
dd a
gain
.Th
e m
otor
will
osci
llate
. The
pro
gram
inst
ruct
ion
have
now
bee
n co
pied
to
the
new
rem
ote
Dele
te M
emor
y
a) P
ress
and
hol
d th
e PR
OG
RAM
but
ton
on th
e he
ad
of th
e m
otor
for 7
sec
onds
, (th
e m
otor
will
osci
llate
)ke
ep h
oldi
ng th
e bu
tton
anot
her 5
sec
onds
. (th
e m
otor
w
ill os
cilla
te tw
o m
ore
times
).
The
mem
ory
has
been
era
sed
from
the
mot
or
You
mus
t fol
low
thes
e ins
truct
ions
in th
e sam
e ord
er th
ey a
ppea
r on
this
shee
t oth
erwi
se th
e com
man
ds w
ill n
ot b
e abl
e to
be d
one
Vert
ilux
ceLT
ic ii
- Te
chni
cal c
atal
ogue
CEL
TIC
II-
RF &
Qui
et M
otor
s Ba
sic
Prog
amm
ing
Inst
ruct
ions
com
mo
N F
uN
cTi
oN
s
FuN
cTi
oN
PRo
GRa
mm
abL
e Fu
Nc
Tio
NsT
ePs
Nee
DeD
/ TR
aN
smiT
TeR
buTT
oN
sN
oTe
sso
uN
Ds
emiT
TeD
by
mo
ToR
1C
omm
unic
ate
Tran
smitt
er
with
Mot
or
a) D
isco
nnec
t the
mot
or-
-
b) P
ress
the
UP
for 2
sec
onds
& C
onne
ct M
otor
Con
nect
mot
or w
hile
pre
ssin
g th
e U
P bu
tton
Five
sho
rt 'b
eeps
'
c) P
ress
the
UP
butto
n (W
ithin
the
five
beep
s)W
ithin
the
five
beep
s yo
u m
ust r
elea
se th
e U
P bu
tton
and
pres
s it
agai
n on
ceTh
ree
shor
t 'be
eps'
2C
hang
e Di
rect
ion
of M
otor
a) H
old
the
STO
P bu
tton
Hol
d th
is b
utto
n un
til m
otor
em
its s
ound
Five
sho
rt 'b
eeps
'
b) P
ress
UP
butto
nIf
dire
ctio
n is
the
oppo
site
than
the
one
desi
red,
th
en re
peat
ste
p us
ing
the
DO
WN
but
ton
inst
ead
Thre
e sh
ort '
beep
s'
Less
co
mm
oN
Fu
Nc
Tio
Ns
FuN
cTi
oN
PRo
GRa
mm
abL
e Fu
Nc
Tio
NsT
ePs
Nee
DeD
/ TR
aN
smiT
TeR
buTT
oN
sN
oTe
sso
uN
Ds
emiT
TeD
by
mo
ToR
3C
onne
ct a
n ex
tra T
rans
mitt
er
a) O
n an
alre
ady
prog
ram
med
tran
smitt
er, p
ress
&
hold
: STO
PH
old
this
but
ton
until
mot
or e
mits
sou
ndFi
ve s
hort
'bee
ps'
b) O
n ne
w tr
ansm
itter
, pre
ss &
hol
d: U
PH
old
this
but
ton
until
mot
or e
mits
sou
ndTh
ree
shor
t ‘be
eps’
4De
lete
Mem
ory*
a) P
ress
the
STO
P bu
tton
Hol
d th
is b
utto
n un
til m
otor
em
its s
ound
Five
sho
rt ‘b
eeps
’
b) P
ress
the
PRO
GR
AM b
utto
n W
ithin
the
five
beep
sTh
ree
shor
t ‘be
eps’
5C
hang
e to
Jog
Mod
e an
d Vi
ce V
ersa
**
a) P
ress
the
STO
P bu
tton
Hol
d th
is b
utto
n un
til m
otor
em
its s
ound
Five
sho
rt ‘b
eeps
’
b) P
ress
the
STO
P bu
tton
agai
nW
ithin
the
five
beep
sTh
ree
shor
t ‘be
eps’
* T
his
is c
onve
nien
t whe
n th
ere
has
been
a p
rogr
amm
ing
mis
take
and
sta
rting
the
who
le p
rogr
amm
ing
is n
eede
d.
** “J
og M
ode”
mak
es th
e m
otor
mak
e a
shor
t mov
emen
t whe
n pr
essi
ng th
e up
or d
own
butto
ns. W
hen
in th
is m
ode,
to m
ake
the
mot
or m
ove
cont
inua
lly, t
he u
p or
do
wn
butto
n m
ust b
e pr
esse
d fo
r 3 s
econ
ds. T
he “j
og m
ode”
is c
onve
nien
t for
ven
etia
n bl
inds
(woo
d al
umin
um) s
ince
it a
llow
s til
ting
the
slat
s in
a m
ore
prec
ise
way
.
Vert
ilux
ceLT
ic ii
- Te
chni
cal c
atal
ogue
CEL
TIC
II-
Elec
troni
c M
otor
s Ba
sic
Prog
amm
ing
Inst
ruct
ions
com
mo
N F
uN
cTi
oN
s
Fu
Nc
Tio
NPR
oG
Ram
ma
bLe F
uN
cTi
oN
sTeP
s Nee
DeD
/ TRa
Nsm
iTTe
R bu
TTo
Ns
No
Tes
1C
omm
unic
ate
Tran
smitt
er
with
Mot
or
a) D
isco
nnec
t the
mot
or fo
r 10
seco
nds
-
b) C
onne
ct th
e m
otor
-
c) P
ress
UP
& D
OW
N a
t the
sam
e tim
ePr
ess
it un
til th
e m
otor
mov
es b
ack
& fo
rth
d) P
ress
the
PRO
GR
AM b
utto
nPr
ess
it co
ntin
uous
ly u
ntil
the
mot
or m
oves
bac
k &
forth
2C
hang
e Di
rect
ion
of M
otor
*
a) P
ress
the
UP
butto
nIf
mot
or g
oes
DO
WN
follo
w th
e st
ep “b
”, if
it go
es U
P, p
leas
e co
ntin
ue to
STE
P 3
b) P
ress
the
STO
P bu
tton
for 2
sec
onds
Pres
s it
until
the
mot
or m
oves
bac
k &
forth
c) D
isco
nnec
t the
mot
or-
seTT
iNG
Lim
iTs
FuN
cTi
oN
PRo
GRa
mm
abL
e Fu
Nc
Tio
NsT
ePs
Nee
DeD
/ TR
aN
smiT
TeR
buTT
oN
sN
oTe
s
3Se
t LO
WER
Lim
it
a) P
ress
DO
WN
& S
TOP
at th
e sa
me
time
The
mot
or w
ill go
DO
WN
con
tinuo
usly
b) W
hen
you
get t
o th
e ex
pect
ed p
ositi
on, p
ress
th
e ST
OP
butto
nIf
not a
t the
exp
ecte
d po
sitio
n, p
ress
the
UP
or th
e DO
WN
but
ton
to
adju
st th
e lim
it
c) W
hen
you
have
the
exac
t pos
ition
, pre
ss th
e ST
OP
butto
n ag
ain
Pres
s it
cont
inuo
usly
unt
il th
e m
otor
mov
es b
ack
& fo
rth. Y
our l
ower
lim
it ha
s be
en s
et
4Se
t UPP
ER L
imit
a) P
ress
the
PRO
GR
AM b
utto
n Th
e m
otor
will
mov
e ba
ck &
forth
(thi
s is
don
e to
let t
he s
hade
kno
w th
at
it is
cha
ngin
g di
rect
ion)
b) P
ress
UP
& ST
OP
at th
e sa
me
time
The
mot
or w
ill go
UP
cont
inuo
usly
c) W
hen
you
have
the
exac
t pos
ition
, pre
ss th
e ST
OP
butto
nIf
not a
t the
exp
ecte
d po
sitio
n, p
ress
the
UP
or th
e DO
WN
but
ton
to
adju
st th
e lim
it
Whe
n yo
u ha
ve th
e ex
act p
ositi
on, p
ress
the
STO
P bu
tton
agai
nPr
ess
it co
ntin
uous
ly u
ntil
the
mot
or m
oves
bac
k &
forth
. You
r upp
er li
mit
has
been
set
You
mus
t fol
low
thes
e ins
truct
ions
in th
e sam
e ord
er th
ey a
ppea
r on
this
shee
t oth
erwi
se th
e com
man
ds w
ill n
ot b
e abl
e to
be d
one
Vert
ilux
ceLT
ic ii
- Te
chni
cal c
atal
ogue
CEL
TIC
II-
Elec
troni
c M
otor
s Ba
sic
Prog
amm
ing
Inst
ruct
ions
seTT
iNG
Lim
iTs
FuN
cTi
oN
PRo
GRa
mm
abL
e Fu
Nc
Tio
NsT
ePs
Nee
DeD
/ TR
aN
smiT
TeR
buTT
oN
sN
oTe
s
5Ad
just
ing
the
Lim
its**
a) P
ress
all
the
way
UP
or a
l the
way
DO
WN
If yo
u no
tice
that
you
nee
d to
adj
ust t
he li
mits
, fol
low
nex
t ste
ps
b) P
ress
UP
& D
OW
N a
t the
sam
e tim
ePr
ess
it un
til th
e m
otor
mov
es b
ack
& fo
rth
c) P
ress
the
UP
or th
e D
OW
N b
utto
n to
adj
ust t
he li
mit
-
d) P
ress
STO
P Pr
ess
it un
til th
e m
otor
goe
s ba
ck &
forth
Less
co
mm
oN
Fu
Nc
Tio
Ns
PRo
GRa
mm
abL
e Fu
Nc
Tio
NsT
ePs
Nee
DeD
/ TR
aN
smiT
TeR
buTT
oN
sTh
e m
oTo
R w
iLL
mo
Ve b
ack
& F
oRT
h
Con
nect
an
extra
Tra
nsm
itter
On
the
seco
nd tr
ansm
itter
, pre
ss b
oth
UP
& D
OW
N
butto
ns a
t the
sam
e tim
eTh
e m
otor
will
mov
e ba
ck &
forth
Pres
s th
e PR
OG
RAM
but
ton
Dele
te M
emor
y***
Disc
onne
ct th
e m
otor
for 1
0 se
cond
s-
Con
nect
the
mot
or-
Pres
s bo
th U
P &
DO
WN
at t
he s
ame
time
Pres
s it
until
the
mot
or m
oves
bac
k &
forth
Pres
s PR
OG
RAM
but
ton
for 1
0 to
12
seco
nds
Pres
s it
until
the
mot
or m
oves
bac
k &
forth
aga
in
* A
fter p
rogr
amm
ing
chec
k th
e di
rect
ion,
if d
irect
ion
is re
vers
ed, c
hang
e it
as in
dica
ted.
If th
e di
rect
ion
is c
orre
ct; c
ontin
ue w
ith s
econ
d pr
ogra
mm
ing
step
. Cha
ngin
g
d
irect
ing
can
only
be
done
bef
ore
setti
ng th
e lim
its; a
lso
it ca
n on
ly b
e do
ne o
nce.
If y
ou n
eed
to d
o it
agai
n, y
ou w
ould
hav
e to
del
ete
and
star
t all
over
.
The
mot
or’s
pola
rity
is s
et fo
r the
mot
or to
be
on th
e le
ft by
def
ault.
If th
e m
otor
is o
n th
e rig
ht y
ou m
ust c
hang
e th
e di
rect
ion
first
** T
his
step
is u
sual
ly d
one
at th
e in
stal
latio
n si
te. A
fter s
ettin
g th
e lim
it po
sitio
ns, i
f the
lim
it is
a li
ttle
off a
t ins
talla
tion
site
, the
n yo
u ca
n do
this
ste
p.**
* Thi
s is
con
veni
ent w
hen
ther
e ha
s be
en a
pro
gram
min
g m
ista
ke a
nd s
tarti
ng th
e w
hole
pro
gram
min
g is
nee
ded.
Not
e: Y
ou m
ust f
ollo
w th
ese
inst
ruct
ions
in th
e sa
me
orde
r the
y ap
pear
on
this
she
et o
ther
wis
e th
e co
mm
ands
will
not b
e ab
le to
be
done
. You
MU
ST e
rase
and
sta
rt ov
er e
ach
time
you
mak
e a
mis
take
in th
e pr
ogra
mm
ing.
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
PROGRAMMING INSTRUCTIONS
RS232
THIS PAGE HAS BEEN
INTENTIONALLY LEFT BLANK
77 Vertilux CELTIC II - Technical Catalogue
CELTIC II - RS232 to RF Programming Instructions
Computer Controlled Radio Transmitter Manual
moDeL No. RaTeD VoLTaGe woRkiNG TemP woRkiNG cuRReNT LoaDiNG PoweR FReQueNcy chaNNeL No. oPeRaTioN moDe
AC117-01(Optional)
230VAC 50Hz120VAC 60Hz
0°C ≈ +70°C ≤ 20mA ≤ 20mW 433.92MHz 15 channel Computer Control/ manual
1- Specifications
2. Parameters
3. Wiring
4. Download and Install
Program button Antenna
Computer COM interface
Connect computers
RJ11
RJ11
Group control DOWN buttonGroup control STOP button
Group control UP button
AC POWER AC POWER AC POWER
1. Install AccessPort software from Performance Concepts webpage or CD-ROM o Run AccessPort.exe o Or extract AccessPort.rar to your desktop using WinRar then run AccessPort.exe2. Connect laptop to AC117 by first connecting USB-to-Serial adapter to Serial-to- RJ-11 adapter3. Provide 110VAC power to AC117 and Red LED will indicate that the device is powered up.
Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD
• Extendable antenna• Can daisy-chain (5) AC117-01 together• Multi-programmable operation• SMT machine assembly, damp proof enclosure
78 Vertilux CELTIC II - Technical Catalogue
CELTIC II - RS232 to RF Integration Device
78
4
3
5
12
6
5. OPTIONS
Fill control code in the textbox (Please reference UP code in the right control code list) Click on “Send”.
Fill control code in the textbox (Please reference STOP code in the right control code list) Click on “Send”.
Fill control code in the textbox (Please reference DOWN code in the right control code list) Click on “Send “.
UP
STOP
SETTING
DOWN
Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD
79 Vertilux CELTIC II - Technical Catalogue
CELTIC II - RS232 to RF Integration Device
1 3
After the shades and draperies have been installed and are working as you want them to with the correct channels on thevarious keypads/transmitters, reference these instructions so that you can pair the RS232-RF device to the shades and draperies:
Pairing the RS232-RF Device to a Roller Shade utilizing a laptop PC
1. Determine the UP control code channel you will use (e.g. FF 10 11 07 DD) and type that into the lower text box so that it is ready for you to click the SEND button
• CAUTION – Never assign the group control FF 10 11 00 DD in this step as doing so will prevent you from creating sub-groups.• The commands FF 10 11 00 DD, FF 10 11 00 CC, and FF 10 11 00 EE should only be used as master override channels (after pairing has been completed) and are never utilized during the pairing step.
2. Press and hold STOP button of the existing transmitter or keypad until you hear 5 beeps3. During the 5 beeps, send the correct UP control code (e.g. FF 10 11 07 DD) by clicking SEND4. If the RS232-RF signal was received by the roller shade motor, you will hear 3 beeps.5. Ensure that the RS232-RF device is working by sending UP, STOP, and DOWN control codes. If the device is not working properly, start over.
Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD
80 Vertilux CELTIC II - Technical Catalogue
CELTIC II - RS232 to RF Integration Device
Pairing the RS232-RF Device to a Drapery Track utilizing a laptop PC
1. Determine the STOP control code channel you will use (e.g. FF 10 11 09 CC) and type that intothe lower text box so that it is ready for you to click the SEND button2. Press and hold STOP the PROGRAMMING button on bottom of motor until the RED LED flashes3. While the RED LED is flashing, send the correct STOP control code (e.g. FF 10 11 09 CC) andwithin 5 seconds, SEND the correct UP control code (e.g. FF 10 11 09 DD) by changing the lasttwo letters of the string from CC to DD.
4. Ensure that the RS232-RF device is working by sending UP, STOP, and DOWN control codes. Ifthe device is not working properly, start over.
Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD
1 3
81 Vertilux CELTIC II - Technical Catalogue
CELTIC II - RS232 Interface Programming Codes
uP coNTRoL coDes:
GRouP coNTRoL FF 10 11 00 DD
1ST GROUP FF 10 11 01 DD 2ND GROUP FF 10 11 02 DD 3rd GROUP FF 10 11 03 DD 4th GROUP FF 10 11 04 DD 5th GROUP FF 10 11 05 DD 6th GROUP FF 10 11 06 DD 7th GROUP FF 10 11 07 DD 8th GROUP FF 10 11 08 DD 9th GROUP FF 10 11 09 DD 10th GROUP FF 10 11 0A DD 11th GROUP FF 10 11 0B DD 12th GROUP FF 10 11 0C DD 13th GROUP FF 10 11 0D DD 14th GROUP FF 10 11 0E DD 15th GROUP FF 10 11 0F DD
DowN coNTRoL coDes:
GRouP coNTRoL FF 10 11 00 ee
1ST GROUP FF 10 11 01 EE 2ND GROUP FF 10 11 02 EE 3rd GROUP FF 10 11 03 EE 4th GROUP FF 10 11 04 EE 5th GROUP FF 10 11 05 EE 6th GROUP FF 10 11 06 EE 7th GROUP FF 10 11 07 EE 8th GROUP FF 10 11 08 EE 9th GROUP FF 10 11 09 EE 10th GROUP FF 10 11 0A EE 11th GROUP FF 10 11 0B EE 12th GROUP FF 10 11 0C EE 13th GROUP FF 10 11 0D EE 14th GROUP FF 10 11 0E EE 15th GROUP FF 10 11 0F EE
sToP coNTRoL coDes:
GRouP coNTRoL FF 10 11 00 cc
1ST GROUP FF 10 11 01 CC 2ND GROUP FF 10 11 02 CC 3rd GROUP FF 10 11 03 CC 4th GROUP FF 10 11 04 CC 5th GROUP FF 10 11 05 CC 6th GROUP FF 10 11 06 CC 7th GROUP FF 10 11 07 CC 8th GROUP FF 10 11 08 CC 9th GROUP FF 10 11 09 CC 10th GROUP FF 10 11 0A CC 11th GROUP FF 10 11 0B CC 12th GROUP FF 10 11 0C CC 13th GROUP FF 10 11 0D CC 14th GROUP FF 10 11 0E CC 15th GROUP FF 10 11 0F CC
RS232 Interface Programming Codes
M I A M I . D A L L A S . L O S A N G E L E S
VERTILUX, L td .
Headquar ters : 7300NW35thTer race, Miami , F l , 33122
Phone: 1.800.356.8837 - Fax: 1.800.275.1719
www.verti lux.com
AUTHORIZEDDISTRIBUTOR: