Top Banner
FOR THE AUTOMATION OF BLINDS AND SHADES
82

Technical Catalog Celtic II (EN)

Mar 12, 2016

Download

Documents

Celtic II Motors by Vertilux include a wide range of options for automation of Roller Shades, Roman Shades, Horizontal Blinds, Draperies, Sliding Panels, and other types of window coverings.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Technical Catalog Celtic II (EN)

FOR THE AUTOMATION OF BLINDS AND SHADES

Page 2: Technical Catalog Celtic II (EN)

vert

ilux.

com

Page 3: Technical Catalog Celtic II (EN)

For the Automation of Blinds and Shades

The Vertilux Motorization systems eliminate the need for manual

operation of Blinds and Shades creating a merger between the

vanguard in technology and decorative style while at the same time

keeping a balance in making it a cost effective solution.

Page 4: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 5: Technical Catalog Celtic II (EN)

5 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Benefits

Motorized blinds and draperies were thought of as an indulgence available only to the elite several years

ago. But today’s hardware, technology and pricing have made this onetime luxury easily available to the

general public. Motorized blinds, shades and draperies offer many benefits for many people. Parents with

young children, the elderly and even just the average person will benefit from having motorized window

coverings, which eliminate the need to fuss with wands or cords. If you suffer from mobility or dexterity issues,

or are just tired of dealing with tangled cords, this investment can help your window coverings function

flawlessly and look spectacular

Motorization can be used for virtually any type of window treatment, from blinds to shades to drapery.

Even those high windows you can hardly reach enough to clean can suddenly have window treatments

you can operate with ease, thanks to motorization. As one of the most revolutionary trends in the industry,

motorized operating systems offer the convenience and luxury of controlling your window covers from the

comfort of your bed, sofa, and dining room table – anywhere you like. However, motorization is more than

just a convenience. It also offers increased energy efficiency and safety, a true win-win in many aspects. In

residential applications with just the click of a button, motorization allows you to raise and lower treatments,

adjust slats and vanes, rotate and move from side to side, all with the ease and simplicity of a battery

operated remote. Just point and press! However, you can even take it one step further, with hard-wired

technology, with a home automation system.

When your windows are very high, a motorized shade can help maximize functionality. I would recommend

that an installation like this be hardwired with either a remote or wall switch, so you can avoid having to get

the ladder out to change the batteries.

If you have a large window, the weight of one blind can sometimes be too heavy for one person to lift. This

is a perfect situation for a motorized blind.

Hard wired motorization enables you to control your window coverings through a switch on your wall, just

like a light switch, which fits seamlessly with any décor. You can program various positions for your window

treatments and still benefit from the use of an integrated remote. With hard wired motorization, you’ll enjoy

extreme accuracy and precision.

Page 6: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 7: Technical Catalog Celtic II (EN)

7 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux Rechargeable Battery Motor

Technical Specifications

Weight Capacity

Radio Frequency

Item Code: 6-700-CM-25E02

Motor Diameter: Series 25mm

Motor Length: 16 in

Functional Tubes: Keyed 1.5” (38mm) Tube

Limits: Electronic

Time of Operation: 4 Minutes

Power: DC 12V. Internal Battery Amps: 900m A. Output: 1 Nm | 30 RPM

Recommended use: Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...

Tube DiameTeR Nm: 1.0 RPm: 30

1.5” 44mm / 50mm / 55mm / 60mm / 65mm / 78mm /

kg lb kg lb kg lb kg lb kg lb kg lb kg lb

3.7 8.2 - - - - - - - -

Internal Rechargeable Battery

MODEL: 6-700-CM-25E02

ITEM CODE: 6-700-CM-25E02

Page 8: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 9: Technical Catalog Celtic II (EN)

9 Vertilux CELTIC II - Technical Catalogue

CELTIC II -

9

Battery System for Neolux Dual Shades and Roller Shades

Neolux Roller Shades with Rechargeable Battery Motor

5

3

4

6

2

8

1

7

3

5

Light Gap = LGMeasurement include adapters

0.75 ''

LG Motor

0.5 ''

LG End Plug *Measurements will vary depending on the fabric

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-25E02 Celtic II Battery Motor Internal Power 1 EA

20-149-12-CAVXX Rollux- Aluminum Cassette 120 * 1 EA

0-149-10-CAVXX Rollux- Aluminum Cassette 100 ** 1 EA

30-149-12-BR08I Rollux- Cassette 120 Bracket 2 EA

0-149-10-BR08I Vertilux- Cassette 100 Bracket 2 EA

4 0-149-08-E38WH Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White 1 EA

50-149-12-CO0XX Rollux- Cassette 120 End Cover *** 2 EA

0-149-10-CO0XX Rollux- Cassette 100 End Cover **** 2 EA

60-149-12-BRMWH Rollux- Cassette 120 Mounting Bracket White 3 EA

0-149-10-BRMWH Rollux- Cassette 100 Mounting Bracket 3 EA

7 6-200-60-70427 Motor Plate for 400 Series Motor 1 EA

8 0-154-TU-00038 Rollux 1 1/2” (38mm) Aluminum Tube with Tape 16’ Mill Finish ***** - -

9 6-700-CM-DC001 Celtic ll Charger for Battery Motor with Internal Battery 1 EA

***** Maximum recommended tube length is 7 FT.

Individual Components Itemized

84”

84”Maximum

Shade Size*

* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black.

Page 10: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 11: Technical Catalog Celtic II (EN)

11 Vertilux CELTIC II - Technical Catalogue

CELTIC II -

External Battery Wand

Vertilux Rechargeable Battery Motor with Solar Panel

Technical Specifications

Weight Capacity

Radio Frequency

Item Code: 6-700-CM-25E01

Motor Diameter: Series 25mm

Motor Length: 16 in

Functional Tubes: Keyed 1.5” (38mm) Tube

Limits: Electronic

Time of Operation: 4 Minutes

Power: DC 12V. Ext. Power: Battery Wand, Solar Panel Amps: 900m A. Output: 1 Nm | 30 RPM

Recommended use: Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...

Tube DiameTeR Nm: 1.0 RPm: 30

1.5” 44mm / 50mm / 55mm / 60mm / 65mm / 78mm /

kg lb kg lb kg lb kg lb kg lb kg lb kg lb

3.7 8.2 - - - - - - - -

MODEL: 6-700-CM-25E01

ITEM CODE: 6-700-CM-25E01

Page 12: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 13: Technical Catalog Celtic II (EN)

13 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Neolux & Roller Shade Battery System

5

3

4

6

2

8

9

1

7

3

5

Light Gap = LGMeasurement include adapters

0.75 ''

LG Motor

0.5 ''

LG End Plug *Measurements will vary depending on the fabric

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-25E01 Celtic II Battery Motor External Power 1 EA

20-149-12-CAVXX Rollux- Aluminum Cassette 120 * 1 EA

0-149-10-CAVXX Rollux- Aluminum Cassette 100 ** 1 EA

30-149-12-BR08I Rollux- Cassette 120 Bracket 2 EA

0-149-10-BR08I Vertilux- Cassette 100 Bracket 2 EA

4 0-149-08-E38WH Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White 1 EA

50-149-12-CO0XX Rollux- Cassette 120 End Cover *** 2 EA

0-149-10-CO0XX Rollux- Cassette 100 End Cover **** 2 EA

60-149-12-BRMWH Rollux- Cassette 120 Mounting Bracket White 3 EA

0-149-10-BRMWH Rollux- Cassette 100 Mounting Bracket 3 EA

7 6-200-60-70427 Motor Plate for 400 Series Motor 1 EA

8 0-154-TU-00038 Rollux 1 1/2” (38mm) Aluminum Tube with Tape 16’ Mill Finish ***** - -

9 6-700-01-BPOLE Battery Pole 2 EA

***** Maximum recommended tube length is 7 FT.

Individual Components Itemized

Battery System for Neolux Dual Shades and Roller Shades

84”

84”Maximum

Shade Size*

* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black.

Page 14: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 15: Technical Catalog Celtic II (EN)

15 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux Motor 35mm Series

Technical Specifications

Weight Capacity

Radio Frequency

Item Code: 6-700-CM-35E10

Motor Diameter: Series 35mm

Motor Length: 24 in

Functional Tubes: Round Smooth 40mm - 50mm

Limits: Electronic

Time of Operation: 4 Min

Power: AC 120V.50/60 Hz Amps: 0.96 A Output: 10 Nm | 15 RPM

Recommended use: Neolux Dual Shades and 2” Horizontal Blinds

Tube DiameTeR Nm: 6 RPm: 33

40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”

kg lb kg lb kg lb kg lb kg lb kg lb kg lb

15 33 13.63 30 12 26.4 - - - - - - - -

MODEL: 6-700-CM-35E10

ITEM CODE: 6-700-CM-35E10

Page 16: Technical Catalog Celtic II (EN)

16 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Neolux Dual Shade System

5

3

4

6

28

9

1

7

3

5Light Gap = LG

Measurement include adapters0.75 ''

LG Motor

0.5 ''

LG End Plug *Measurements will vary depending on the fabric

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-35R06 Celtic II 35MM RF Motor 120V/33 RPM / 6NM 1 EA

20-149-12-CAVXX Rollux- Aluminum Cassette 120 * 1 EA

0-149-10-CAVXX Rollux- Aluminum Cassette 100 ** 1 EA

30-149-12-BR08I Rollux- Cassette 120 Bracket 2 EA

0-149-10-BR08I Vertilux- Cassette 100 Bracket 2 EA

4 0-154-EW-CA038 Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White 1 EA

50-149-12-CO0XX Rollux- Cassette 120 End Cover *** 2 EA

0-149-10-CO0XX Rollux- Cassette 100 End Cover **** 2 EA

60-149-12-BRMWH Rollux- Cassette 120 Mounting Bracket White 3 EA

0-149-10-BRMWH Rollux- Cassette 100 Mounting Bracket 3 EA

7 6-200-60-70427 Motor Plate for 400 Series Motor 1 EA

8 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finished ***** - -

9 6-700-AS-35040 Celtic II Crown and Drive (40mm) mm 1 EA

***** Maximum recommended tube length is 10 FT.

Individual Components Itemized

System for Neolux Dual Shades and Roller Shades

108”

108”Maximum

Shade Size*

* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black.

Page 17: Technical Catalog Celtic II (EN)

17 Vertilux CELTIC II - Technical Catalogue

CELTIC II - 2” Horizontal Blinds System

4

8

9

6

6

7

6

32

6

5

4

3

1

*Measurements will vary depending on the fabric

* Quantities depend on size of shade. Substitute XXX by 700=Natural, 708=White Birch, 710=Bleach Wood, 722=Sugar Maple, 726=Golden Oak, 728=Cherry. ** Maximum recommended tube length is 10 FT.

System for Roman Shades and Wood Blinds

Individual Components Itemized

No. iTem No. DescRiPTioN QTy uNiT

1 0-074-50-WXXXH Louverlux - 2" Headrail * 192 FT BOX

2 0-098-CA-01100 Louverwood - 2" Center Support Bracket 1 EA

3 0-098-ES-XXXX 2" Inst. Brackets White Satin (Pair) 1 EA

4 6-200-60-80251 Motor/Idler Bkt for 2" Headrail (LS40) 2 EA

5 6-200-60-90186 40mm Octagonal End Cap 40/8 1 EA

6 6-200-61-80391 40mm CTS Kit (Cone CTS 40) 1 - EA

7 6-200-60-50521 40 mm Octagonal Tube ** - -

8 6-700-CM-35E10 Celtic II RF Electric Motor 120V/ 17rpm/ 35mm/ 10Nm 1 EA

9 6-700-AS-35OCT Celtic II Crown & Drive (Octagonal) for CM35 Motors 1 EA

120”

120”Maximum

Shade Size*

Page 18: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 19: Technical Catalog Celtic II (EN)

19 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux 35 mm Motor, 6 Nm, Mechanical Limits

Technical Specifications

Weight Capacity

Item Code: 6-700-CM-35R06

Motor Diameter: Series 35mm

Motor Length: 24 in

Functional Tubes: Round Smooth 40mm - 50mm

Limits: Mechanical

Time of Operation: 4 Min

Power: AC 120V.50/60 Hz Amps: 0.96 A Output: 6 Nm | 33 RPM

Recommended use: Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...

Tube DiameTeR Nm: 6 RPm: 33

40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”

kg lb kg lb kg lb kg lb kg lb kg lb kg lb

15 33 13.63 30 12 26.4 - - - - - - - -

Radio Frequency

MODEL: 6-700-CM-35R06

ITEM CODE: 6-700-CM-35R06

Page 20: Technical Catalog Celtic II (EN)

20 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Single Roller Shade System

Light Gap = LGMeasurement include adapters

0.5''

LG Motor

0.5''

LG End Plug *Measurements will vary depending on the fabric

Roller Shade System Components

120”

120”Maximum

Shade Size*

3 8

1

7

9

4

2

5

6

2

4

3

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-35R06 Celtic II 35MM RF Motor 120V/33 RPM / 6NM 1 EA

2 0-154-PB-00300 Celtic Universal Bracket (CUB) Small Female Bracket 2 EA

3 0-154-PC-001XX Celtic Universal Bracket (CUB) Small Bracket Cover * 2 EA

4 0-154-PC-003XX Celtic Universal Bracket (CUB) Small Bracket Screw Cover * 2 EA

50-154-PE-00501 Celtic Universal Bracket (CUB) 38mm End Plug - White 1 EA

0-154-PE-03301 Celtic Universal Bracket (CUB) 38mm End Plug - Black 1 EA

60-154-PS-00500 Celtic Universal Bracket (CUB) Snap-in End Support - White 1 EA

0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-in End Support - Black 1 EA

7 6-700-AS-35040 Celtic II Crown and Drive (40mm) for CM 35 Motors mm 1 EA

8 6-700-BR-SQ001 Installation 10mm Motor Block 1 EA

9 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finish ** - -

Individual Components Itemized

* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 10 FT.

Page 21: Technical Catalog Celtic II (EN)

21 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Single Cassette Roller Shade System

5

3

4

6

28

9

1

7

3

5Light Gap = LG

Measurement include adapters0.75 ''

LG Motor

0.5 ''

LG End Plug *Measurements will vary depending on the fabric

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-35R06 Celtic II 35MM RF Motor 120V/33 RPM / 6NM 1 EA

20-149-12-CAVXX Rollux - Aluminum Cassette 120 * 1 EA

0-149-10-CAVXX Rollux - Aluminum Cassette 100 ** 1 EA

30-149-12-BR08I Rollux - Cassette 120 Bracket 2 EA

0-149-10-BR08I Vertilux - Cassette 100 Bracket 2 EA

4 0-154-EW-CA038 Rollux - Cassette 100/120 End Plug 1 1/2" (38mm) White 1 EA

50-149-12-CO0XX Rollux - Cassette 120 End Cover *** 2 EA

0-149-10-CO0XX Rollux - Cassette 100 End Cover **** 2 EA

60-149-12-BRMWH Rollux - Cassette 120 Mounting Bracket White 3 EA

0-149-10-BRMWH Rollux - Cassette 100 Mounting Bracket 3 EA

7 6-200-60-70427 Motor Plate for 400 Series Motor 1 EA

8 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finished ***** - -

9 6-700-AS-35040 Celtic II Crown and Drive (40mm) mm 1 EA

***** Maximum recommended tube length is 10 FT.

Individual Components Itemized

System for Neolux Dual Shades and Roller Shades

120”

120”Maximum

Shade Size*

* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black.

Page 22: Technical Catalog Celtic II (EN)

22 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Intermediate Double Motorized Roller Shade System, Mechanical Limits

* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper.

Roller Shade System Components with Intermediate Bracket

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-35R06 Celtic II 35MM RF Motor 120V/33 RPM / 6NM 1 EA

2 0-154-AD-RA250 Rollux End Plug Adapter 2” (50mm) Tube 1 EA

3 0-154-PB-00300 Celtic Universal Bracket (CUB) Small Female Bracket 2 EA

4 0-154-PC-001XX Celtic Universal Bracket (CUB) Small Bracket Cover * 2 EA

5 0-154-PC-003XX Celtic Universal Bracket (CUB) Small Bracket Screw Cover * 2 EA

60-154-PE-00501 Celtic Universal Bracket (CUB) 38mm End Plug - White 1 EA

0-154-PE-03301 Celtic Universal Bracket (CUB) 38mm End Plug - Black 1 EA

70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-in End Support - White 1 EA

0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-in End Support - Black 1 EA

8 6-700-AS-35050 Celtic II Crown and Drive 50 mm 1 EA

9 6-700-BR-SQ001 Installation 10mm Motor Block 1 EA

10 6-700-AD-DL170 Celtic Drive (50mm) for VM35 Motors 2 EA

11 6-700-BR-DZ131 Center Support Bracket for 35mm Motors ** 1 EA

12 0-154-TU-3MM50 Rollux 3x50mm Alluminum Tube / no Tape ***

Individual Components Itemized

10

3

5

5

3

94

1

8

12

1112

67

4*Measurements will vary depending on the fabric

120”

120”Maximum

Shade Size*

*** Maximum recommended tube length is 10 FT.** The center support bracket reduces motor’s performance by approximately 15%

Light Gap = LGMeasurement include adapters

0.5''

LG Motor

0.5''

LG End Plug

Page 23: Technical Catalog Celtic II (EN)

23 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Motorized Roller Shade with Hook Mount (HM) System, Mechanical Limits

Light Gap = LGMeasurement include adapters

0.5”

LG Motor

0.5”

LG End Plug

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-35R06 Celtic II 35MM RF Motor 120V/33 RPM / 6NM 1 EA

2 0-155-BW-SL020 Universal Bracket 2” Hook SL-20 2 EA

3 0-155-EW-SLH53 Heavy Duty End Cap 38 mm Hook 1 EA

4 6-700-BR-4SLAM Rollux-CUB Motor Support Black for 35 Motors 1 EA

5 6-700-AS-35040 Celtic II Crown and Drive (40mm) for CM 35 Motors 1 EA

6 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finished * - -

* Maximum recommended tube length is 8 FT.

Individual Components Itemized

*Measurements will vary depending on the fabric

Roller Shade System Components

96”

118”Maximum

Shade Size*

4

31

5

6

2

2

4

Page 24: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 25: Technical Catalog Celtic II (EN)

25 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux 35 mm Motor, 6 Nm, Electronic limits

Technical Specifications

Weight Capacity

Radio Frequency

Item Code: 6-700-CM-35E06

Motor Diameter: Series 35mm

Motor Length: 24 in

Functional Tubes: Round Smooth 40mm - 50mm

Limits: Electronic

Time of Operation: 4 Min

Power: AC 120V.50/60 Hz Amps: 0.96 A Output: 6 Nm | 33 RPM

Recommended use: Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...

Tube DiameTeR Nm: 6 RPm: 33

40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”

kg lb kg lb kg lb kg lb kg lb kg lb kg lb

15 33 13.63 30 12 26.4 - - - - - - - -

ITEM CODE: 6-700-CM-35E06

MODEL: 6-700-CM-35E06

Page 26: Technical Catalog Celtic II (EN)

26 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Single Roller Shade System

Light Gap = LGMeasurement include adapters

0.5''

LG Motor

0.5''

LG End Plug*Measurements will vary depending on the fabric

Roller Shade System Components

120”

120”Maximum

Shade Size*

3 8

1

7

9

4

2

5

6

2

4

3

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-35E06 Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM 1 EA

2 0-154-PB-00300 Celtic Universal Bracket (CUB) Small Female Bracket 2 EA

3 0-154-PC-001XX Celtic Universal Bracket (CUB) Small Bracket Cover * 2 EA

4 0-154-PC-003XX Celtic Universal Bracket (CUB) Small Bracket Screw Cover * 2 EA

50-154-PE-00501 Celtic Universal Bracket (CUB) 38mm End Plug - White 1 EA

0-154-PE-03301 Celtic Universal Bracket (CUB) 38mm End Plug - Black 1 EA

60-154-PS-00500 Celtic Universal Bracket (CUB) Snap-in End Support - White 1 EA

0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-in End Support - Black 1 EA

7 6-700-AS-35040 Celtic II Crown and Drive (40mm) for CM 35 Motors mm 1 EA

8 6-700-BR-SQ001 Installation 10mm Motor Block 1 EA

9 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finish ** - -

Individual Components Itemized

* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 10 FT.

Page 27: Technical Catalog Celtic II (EN)

27 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Single Cassette Roller Shade System

5

3

4

6

28

9

1

7

3

5Light Gap = LG

Measurement include adapters0.75 ''

LG Motor

0.5 ''

LG End Plug *Measurements will vary depending on the fabric

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-35E06 Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM 1 EA

20-149-12-CAVXX Rollux- Aluminum Cassette 120 * 1 EA

0-149-10-CAVXX Rollux- Aluminum Cassette 100 ** 1 EA

30-149-12-BR08I Rollux- Cassette 120 Bracket 2 EA

0-149-10-BR08I Vertilux- Cassette 100 Bracket 2 EA

4 0-154-EW-CA038 Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White 1 EA

50-149-12-CO0XX Rollux- Cassette 120 End Cover *** 2 EA

0-149-10-CO0XX Rollux- Cassette 100 End Cover **** 2 EA

60-149-12-BRMWH Rollux- Cassette 120 Mounting Bracket White 3 EA

0-149-10-BRMWH Rollux- Cassette 100 Mounting Bracket 3 EA

7 6-200-60-70427 Motor Plate for 400 Series Motor 1 EA

8 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finished ***** - -

9 6-700-AS-35040 Celtic II Crown and Drive (40mm) mm 1 EA

Individual Components Itemized

System for Neolux Dual Shades and Roller Shades

120”

120”Maximum

Shade Size*

***** Maximum recommended tube length is 10 FT.

* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black.

Page 28: Technical Catalog Celtic II (EN)

28 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Intermediate Double Motorized Roller Shade System, Electronic Limits

* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper.

Roller Shade System Components with Intermediate Bracket

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-35E06 Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM 1 EA

2 0-154-AD-RA250 Rollux End Plug Adapter 2” (50mm) Tube 1 EA

3 0-154-PB-00300 Celtic Universal Bracket (CUB) Small Female Bracket 2 EA

4 0-154-PC-001XX Celtic Universal Bracket (CUB) Small Bracket Cover * 2 EA

5 0-154-PC-003XX Celtic Universal Bracket (CUB) Small Bracket Screw Cover * 2 EA

60-154-PE-00501 Celtic Universal Bracket (CUB) 38mm End Plug - White 1 EA

0-154-PE-03301 Celtic Universal Bracket (CUB) 38mm End Plug - Black 1 EA

70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-in End Support - White 1 EA

0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-in End Support - Black 1 EA

8 6-700-AS-35050 Celtic II Crown and Drive 50 mm 1 EA

9 6-700-BR-SQ001 Installation 10mm Motor Block 1 EA

10 6-700-AD-DL170 Celtic Drive (50mm) for VM35 Motors 2 EA

11 6-700-BR-DZ131 Center Support Bracket for 35mm Motors ** 1 EA

12 0-154-TU-3MM50 Rollux 3x50mm Alluminum Tube / no Tape *** - -

Individual Components Itemized

10

3

5

5

3

94

1

8

12

1112

67

4

Light Gap = LGMeasurement include adapters

0.5''

LG Motor

0.5''

LG End Plug*Measurements will vary depending on the fabric

120”

120”Maximum

Shade Size*

*** Maximum recommended tube length is 10 FT.** The center support bracket reduces motor’s performance by approximately 15%

Page 29: Technical Catalog Celtic II (EN)

29 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Motorized Roller Shade with Hook Mount (HM) System, Electronic Limits

Light Gap = LGMeasurement include adapters

0.5”

LG Motor

0.5”

LG End Plug

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-35E06 Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM 1 EA

2 0-155-BW-SL020 Universal Bracket 2” Hook SL-20 2 EA

3 0-155-EW-SLH53 Heavy Duty End Cap 38 mm Hook 1 EA

4 6-700-BR-4SLAM Celtic Universal Bracket (CUB) Motor Support Black for 35 Motors 1 EA

5 6-700-AS-35040 Celtic II Crown and Drive (40mm) for CM 35 Motors 1 EA

6 0-151-TU-00002 Rollux 1.5” Motor Tube Mill Finished * - -

* Maximum recommended tube length is 8 FT.

Individual Components Itemized

*Measurements will vary depending on the fabric

Roller Shade System Components

96”

118”Maximum

Shade Size*

4

31

5

6

2

2

4

Page 30: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 31: Technical Catalog Celtic II (EN)

31 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux Ultra Quiet Motor 45mm Series

Technical Specifications

Weight Capacity

Radio Frequency

Item Code: 6-700-RC-00001

Motor Diameter: Series 45mm

Motor Length: 30 in

Functional Tubes: Round Smooth 2” - 2 1/2” | 63mm

Limits: Mechanical

Time of Operation: 4 Min

Power: AC 120V.50/60 Hz Amps: 0.97 A Output: 4 Nm | 33 RPM

Recommended use: Roller Shades

Tube DiameTeR Nm: 4 RPm: 33

40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”

kg lb kg lb kg lb kg lb kg lb kg lb kg lb

- - - - 12 26 - - - - 9.53 21.16 - -

6-700-RC-00001

ITEM CODE: 6-700-RC-00001

Page 32: Technical Catalog Celtic II (EN)

32 Vertilux CELTIC II - Technical Catalogue

CELTIC II -

5

4

8

7

4

3

5

9

3

1

10

2

6

Ultra Quiet Motor, 4 Nm, for Single Roller Shade on 2” Tube

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-RC-00001 Celtic II RF Quiet Motor 120V / 33 rpm / 45 mm / 4 Nm 1 EA

2 0-154-AD-GA025 Rollux - Galaxy Adapter for 2.5" (63mm) Tube White 1 EA

3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA

4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA

5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA

60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA

0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA

70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA

0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA

8 6-700-AS-45063 Roller Crown & Drive Adaptor Set for 2.5" (63mm) Tube 1 EA

9 6-700-BR-SQ001 Installation 10mm Motor Block 1 EA

10 0-154-TU-3MM50 Rollux - 3x50mm Aluminum Tube / no Tape ** - -

System for Ultra Quiet Roller Shade

*Measurements will vary depending on the fabric

144”

144”Maximum

Shade Size*

Individual Components Itemized

* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 12 FT.

Light Gap = LGMeasurement include adaptersLG Motor LG End Plug

w/o cover 0.5”w/cover 0.75”

w/o cover 0.5” w/cover 0.75”

Page 33: Technical Catalog Celtic II (EN)

33 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Ultra Quiet Motor, 4 Nm, for Single Roller Shade on 2.5” Tube

** Maximum recommended tube length is 19 FT.

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-RC-00001 Celtic II RF Quiet Motor 120V / 33 rpm / 45 mm / 4 Nm 1 EA

2 0-154-AD-GA025 Rollux - Galaxy Adapter for 2.5" (63mm) Tube White 1 EA

3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA

4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA

5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA

60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA

0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA

70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA

0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA

8 6-700-AS-45063 Roller Crown & Drive Adaptor Set for 2.5" (63mm) Tube 1 EA

9 6-700-BR-SQ001 Installation 10 mm Motor Block 1 EA

10 0-154-TU-00063 Rollux 2.5” 63 mm Alluminum Tube W/ Tape ** - -

System for Ultra Quiet Roller Shade

Light Gap = LGMeasurement include adaptersLG Motor LG End Plug *Measurements will vary depending on the fabric

144”

144”Maximum

Shade Size*

5

4

8

7

4

3

5

9

3

1

10

2

6

Individual Components Itemized

* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper.

w/o cover 0.5” w/cover 0.75”

w/o cover 0.5”w/cover 0.75”

Page 34: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 35: Technical Catalog Celtic II (EN)

35 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux 20 Nm Motor for Large Roller Shade, Electronic Limits

Technical Specifications

Weight Capacity

Radio Frequency

Item Code: 6-700-CM-45E20

Motor Diameter: Series 45mm

Motor Length: 29 in

Functional Tubes: 2” Smooth - 2 1/2” | 70 & 78mm

Limits: Electronic

Time of Operation: 4 Min

Power: AC 120V.50/60 Hz Amps: 0.98 A Output: 20 Nm | 33 RPM

Recommended use: Oversize Roller Shades

Tube DiameTeR Nm: 20 RPm: 33

40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”

kg lb kg lb kg lb kg lb kg lb kg lb kg lb

- - - - 40 88 - - - - 33.3 73.3 30.5 67.2

6-700-CM-45E20

ITEM CODE: 6-700-CM-45E20

Page 36: Technical Catalog Celtic II (EN)

36 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Single Oversize Roller Shade System

53

4 91

810

2

6

7

3

5

4Light Gap = LG

Measurement include adaptersLG Motor LG End Plug *Measurements will vary depending on the fabric

Individual Components Itemized

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-45E20 Celtic II RF Electronic Motor 120V / 33 rpm / 45mm / 20Nm 1 EA

2 0-154-AD-RA250 Rollux-TM16&TM24 End Plug Adapter for 2"(50mm) Tube Vanilla 1 EA

3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA

4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA

5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA

60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA

0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA

70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA

0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA

8 6-700-AS-45050 Celtic II Drive (50mm) for CM45 1 EA

9 6-700-BR-CO45W Installation Clamp for Celtic II 1 EA

10 0-154-TU-3MM50 Rollux 3 x 50 mm Aluminum Tube / no Tape ** - -

144”

144”Maximum

Shade Size*

Oversize Roller Shade System Components

w/o cover 0.75” w/cover 1”

w/o cover 0.5”w/cover 0.75”

* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 12 FT.

Page 37: Technical Catalog Celtic II (EN)

37 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Intermediate 20 Nm Motorized System for Oversized Roller Shades, Electronic Limits

Individual Components Itemized

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-45E20 Celtic II RF Electronic Motor 120V / 33 rpm / 45mm / 20Nm 1 EA

2 0-154-AD-RA250 Rollux-TM16&TM24 End Plug Adapter for 2"(50mm) 1 EA

3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA

4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA

5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA

60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA

0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA

70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA

0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA

8 6-700-AD-DL170 Celtic Drive (50mm) for VM35 Motors 2 EA

9 6-700-BR-CO45W Installation Clamp for Celtic II 45mm Motors - White motor 1 EA

10 6-700-BR-DZ131 Center Support Bracket VM35-45 Motors** 1 EA

11 0-154-TU-3MM50 Rollux 3X50 mm Aluminum Tube / no Tape *** - -

12 6-700-AS-45050 Celtic II Drive (50mm) for CM45 Motors 1 EA

4 35

91

12

11

8

26

7

10

113

5

4*Measurements will vary depending on the fabric

Oversize Roller Shade System Components

144”

118”Maximum

Shade Size*

Light Gap = LGMeasurement include adaptersLG Motor LG End Plug

w/o cover 0.75” w/cover 1”

w/o cover 0.5”w/cover 0.75”

*** Maximum recommended tube length is 12 FT With 2” Aluminum Tube** The center support bracket reduces motor’s performance by approximately 15% * Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper.

Page 38: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 39: Technical Catalog Celtic II (EN)

39 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux 20 Nm Motor for Large Roller Shade, Mechanical Limits

Technical Specifications

Weight Capacity

Radio Frequency

Item Code: 6-700-CM-45R20

Motor Diameter: Series 45mm

Motor Length: 29 in

Functional Tubes: 2” Smooth - 2 1/2” | 70 & 78mm

Limits: Mechanical

Time of Operation: 4 Min

Power: AC 120V.50/60 Hz Amps: 0.98 A Output: 20 Nm | 33 RPM

Recommended use: Oversize Roller Shades

Tube DiameTeR Nm: 20 RPm: 33

40 mm / 1.57” 44mm / 1.73” 50mm / 2” 55mm / 2.16” 60mm / 2.375” 63mm / 2.5” 78mm / 3”

kg lb kg lb kg lb kg lb kg lb kg lb kg lb

- - - - 40 88 - - - - 33.3 73.3 30.5 67.2

6-700-CM-45R20

ITEM CODE: 6-700-CM-45R20

Page 40: Technical Catalog Celtic II (EN)

40 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Single Oversize Roller Shade System

53

4 91

810

2

6

7

3

5

4*Measurements will vary depending on the fabric

Individual Components Itemized

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-45R20 Celtic II RF Motor 120V / 33 rpm / 45mm / 20Nm 1 EA

2 0-154-AD-RA250 Rollux-TM16&TM24 End Plug Adapter for 2"(50mm) Tube Vanilla 1 EA

3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA

4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA

5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA

60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA

0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA

70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA

0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA

8 6-700-AS-45050 Celtic II Drive (50mm) for CM45 1 EA

9 6-700-BR-CO45W Installation Clamp for Celtic II 1 EA

10 0-154-TU-3MM50 Rollux 3 x 50 mm Aluminum Tube / no Tape ** - -

144”

144”Maximum

Shade Size*

Oversize Roller Shade System Components

Light Gap = LGMeasurement include adaptersLG Motor LG End Plug

w/o cover 0.75” w/cover 1”

w/o cover 0.5”w/cover 0.75”

* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 12 FT.

Page 41: Technical Catalog Celtic II (EN)

41 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Intermediate 20 Nm Motorized System for Oversized Roller Shades, Mechanical Limits

Individual Components Itemized

*** Maximum recommended tube length is 12 FT With 2” Aluminum Tube** The center support bracket reduces motor’s performance by approximately 15%

4 35

91

12

11

8

26

7

10

113

5

4*Measurements will vary depending on the fabric

Oversize Roller Shade System Components

144”

118”Maximum

Shade Size*

Light Gap = LGMeasurement include adaptersLG Motor LG End Plug

w/o cover 0.75” w/cover 1”

w/o cover 0.5”w/cover 0.75”

* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper.

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-CM-45R20 Celtic II RF Motor 120V / 33 rpm / 45mm / 20Nm 1 EA

2 0-154-AD-RA250 Rollux-TM16&TM24 End Plug Adapter for 2"(50mm) 1 EA

3 0-154-PB-00400 Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor) 2 EA

4 0-154-PC-002XX Celtic Universal Bracket (CUB) Large Bracket Cover * 2 EA

5 0-154-PC-004XX Celtic Universal Bracket (CUB) Large Bracket Screw Cover * 2 EA

60-154-PE-00501 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White 1 EA

0-154-PE-03301 Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black 1 EA

70-154-PS-00500 Celtic Universal Bracket (CUB) Snap-In End Support - White 1 EA

0-154-PS-03300 Celtic Universal Bracket (CUB) Snap-In End Support - Black 1 EA

8 6-700-AD-DL170 Celtic Drive (50mm) for VM35 Motors 2 EA

9 6-700-BR-CO45W Installation Clamp for Celtic II 45mm Motors - White motor 1 EA

10 6-700-BR-DZ131 Center Support Bracket VM35-45 Motors** 1 EA

11 0-154-TU-3MM50 Rollux 3X50 mm Aluminum Tube / no Tape *** - -

12 6-700-AS-45050 Celtic II Drive (50mm) for CM45 Motors 1 EA

Page 42: Technical Catalog Celtic II (EN)

vert

ilux.

com

Page 43: Technical Catalog Celtic II (EN)

DASHTRACK

• Traverseupto165lbs.offabric

• Compactandlightweightforsimpleinstallation

• Simpleconnectivitytohome-automationsystems

• Directdriverubberbeltenablesquietoperation

• Harddrawtechnologyavoidsdamagetotheproduct

• DashTrackallowsdraperiestobeoperatedmanually,asafail safe during power outages

• Limitsaresetautomatically

• CompatiblewithallCelticIIControls

The one system for Drapery or Sliding PanelTrack motorization

Page 44: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 45: Technical Catalog Celtic II (EN)

45 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux Dashtrack, for Draperies and Sliding Panels

Technical Specifications

Radio Frequency

Item Number: 6-700-DM-00001

Weight: 165 lbs.

Motor Dimensions: 12.5 x 2.5 in

Limits: Automatic

Time of Operation: 4 Min

Power Transformer: 24V AMP: 2.7 A

Torque: 0.8 NM. RPM: 7.5 in/s

Recommended use: Drapery and Sliding Panels.

Page 46: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 47: Technical Catalog Celtic II (EN)

FOR PINCH PLEAD DRAPERIES

DASHTRACK

Page 48: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 49: Technical Catalog Celtic II (EN)

49 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux Dashtrack System

System for Pinch Plead Drapery

Individual Components Itemized

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-DM-00001 Vertilux Drapery Motor 1Nm/80rpm/24Vdc/65W 1 EA

2 6-700-DM-00002 Vertilux Drapery Motors - 24V Transformer 1 EA

3 6-700-DM-00003 Vertilux Drapery Motors - Main Control End 1 EA

4 6-700-DM-00004 Vertilux Drapery Motors - Secondary Control End 1 EA

5 6-700-DM-00005 Vertilux Drapery Motors - Interior Belt --- FT

6 6-700-DM-00006 Vertilux Drapery Motors - Pinch Plead Carriers --- EA

7 6-700-DM-00008 Vertilux Drapery Motors - Pinch Plead Master Carrier --- EA

8 6-700-DM-00009 Vertilux Drapery Motors - Curtain Track - White 19' --- FT

9 6-700-DM-00010 Vertilux Drapery Motors - Ceiling Clip --- EA

10 6-700-DM-00011 Vertilux Drapery Motors - Plastic Clip --- EA

11 0-030-CA-06600 Vertilux-Adj. "L" Bracket 85-145mm White --- EA

4

41

7

8

86

33

10

Page 50: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 51: Technical Catalog Celtic II (EN)

FOR RIPPLE FOLD DRAPERIES

DASHTRACK

Page 52: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 53: Technical Catalog Celtic II (EN)

53 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux Dashtrack System

System for Ripple Fold Drapery

Individual Components Itemized

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-DM-00001 Vertilux Drapery Motor 1Nm/80rpm/24Vdc/65W 1 EA

2 6-700-DM-00002 Vertilux Drapery Motors - 24V Transformer 1 EA

3 6-700-DM-00003 Vertilux Drapery Motors - Main Control End 1 EA

4 6-700-DM-00004 Vertilux Drapery Motors - Secondary Control End 1 EA

5 6-700-DM-00005 Vertilux Drapery Motors - Interior Belt --- FT

6

6-700-DM- Vertilux Drapery Motors - Ripple Fold Carriers 60% --- FT

6-700-DM-00014 Vertilux Drapery Motors - Ripple Fold Carriers 80% --- FT

6-700-DM-00015 Vertilux Drapery Motors - Ripple Fold Carriers 100% --- FT

6-700-DM-00016 Vertilux Drapery Motors - Ripple Fold Carriers 120% --- FT

7 6-700-DM-00018 Vertilux Drapery Motor - Ripple Fold Master Carrier set --- Set

8 6-700-DM-00009 Vertilux Drapery Motors - Curtain Track - White 19' --- FT

9 6-700-DM-00010 Vertilux Drapery Motors - Ceiling Clip --- EA

10 6-700-DM-00011 Vertilux Drapery Motors - Plastic Clip --- EA

11 0-030-CA-06600 Vertilux-Adj. "L" Bracket 85-145mm White --- EA

4

41

7

8

86

33

10

Page 54: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 55: Technical Catalog Celtic II (EN)

FOR SLIDING PANELS

DASHTRACK

Page 56: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 57: Technical Catalog Celtic II (EN)

57 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Vertilux Dashtrack System

System for Sliding Panel

Individual Components Itemized

No. iTem No. DescRiPTioN QTy uNiT

1 6-700-DM-00001 Vertilux Drapery Motor 1Nm/80rpm/24Vdc/65W 1 EA

2 6-700-DM-00002 Vertilux Drapery Motors - 24V Transformer 1 EA

3 6-700-DM-00003 Vertilux Drapery Motors - Main Control End 1 EA

4 6-700-DM-00004 Vertilux Drapery Motors - Secondary Control End 1 EA

5 6-700-DM-00005 Vertilux Drapery Motors - Interior Belt --- FT

6 6-700-DM-00008 Vertilux Drapery Motors - Pinch Plead Master Carrier --- EA

7 6-700-DM-00009 Vertilux Drapery Motors - Curtain Track - White 19' --- FT

8 6-700-DM-00010 Vertilux Drapery Motors - Ceiling Clip --- EA

9 6-700-DM-00011 Vertilux Drapery Motors - Plastic Clip --- EA

10 0-030-CA-06600 Vertilux-Adj. "L" Bracket 85-145mm White --- EA

4

41

7

8

86

33

10

Page 58: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 59: Technical Catalog Celtic II (EN)

FOR VERTILUX CELTIC II MOTORS

REMOTE CONTROLS

Page 60: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 61: Technical Catalog Celtic II (EN)

61 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Remote Controls for Vertilux Celtic II Motors

One Channel Remote

Six Channel Remote

Item No.: 6-700-AT-CRT01

Item No.: 6-700-AT-CRT06

Controls one single motor

Programs in less tan 10 seconds

Dimensions: 2” x 5”

Frequency: 433.92 Mhz

Distance 50’ with obstructions, 150’ line of site

Portable Control

Controls 5 Motors individually and the 6th Chanel controls all 5 motors simultaneously

Programs in less tan 10 seconds

Dimensions: 2” x 5”

Frequency: 433.92 Mhz

Distance 50’ with obstructions, 150’ line of site

Portable Control

Page 62: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 63: Technical Catalog Celtic II (EN)

63 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Remote Controls for Vertilux Celtic II Motors

Sixteen Channel Remote

Wireless 1 Channel Wall Switch

Item No.: 6-700-AT-CRT16

Item No.: 6-700-AT-CTW01

Controls 15 motors individually and the 16th chanel controls all 15 motors simultaneously

Programs in less tan 10 seconds

Dimensions: 2” x 5”

Frequency: 433.92 Mhz

Distance 50’ with obstructions, 150’ line of site

Portable Control

Controls one single motor

Programs in less tan 10 seconds

Dimensions: 3” x 5”

Frequency: 433.92 Mhz

Distance 50’ with obstructions, 150’ line of site

Wall Fixture Control

Page 64: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 65: Technical Catalog Celtic II (EN)

65 Vertilux CELTIC II - Technical Catalogue

CELTIC II - Remote for Vertilux Celtic II Motors

Wireless 6 Channel Wall Switch

Antenna RS232

Item No.: 6-700-AT-CTW06

Item No.: 6-700-AT-RS232

Controls 5 motors individually and the 6th chanel controls all 5 motors simultaneously

Programs in less tan 10 seconds

Dimensions: 3” x 5”

Frequency: 433.92 Mhz

Distance 50’ with obstructions, 150’ line of site

Wall Fixture Control

Home Automation Interface

Can daisy-chain (5) AC117-01 together

Multi-programmable operation

Dimensions: 8” x 6”

Frequency: 433.92 Mhz

Distance 100’ Radious

Page 66: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 67: Technical Catalog Celtic II (EN)

FRUSTATION FREE PROGRAMMING INSTRUCTIONS

REMOTE CONTROLS

Page 68: Technical Catalog Celtic II (EN)

Vert

ilux

ceLT

ic ii

- Te

chni

cal c

atal

ogue

CEL

TIC

II-

Rem

ote

Prog

ram

min

g

UP

DO

WN

PRO

GRA

M

CH

AN

NEL

UP

BATT

ERY

SCRE

W

TRA

NSM

ISO

R C

ELTI

C II

FRO

NT

VIEW

TRA

NSM

ISO

R C

ELTI

C II

BA

CK

VIE

W

CH

AN

NEL

DO

WN

STO

P

Page 69: Technical Catalog Celtic II (EN)

Vert

ilux

ceLT

ic ii

- Te

chni

cal c

atal

ogue

CEL

TIC

II-

Elec

troni

c Ba

ttery

Mot

or P

roga

mm

ing

Inst

ruct

ions

com

mo

N F

uN

cTi

oN

s

FuN

cTi

oN

PRo

GRa

mm

abL

e Fu

Nc

Tio

NsT

ePs

Nee

DeD

/ TR

aN

smiT

TeR

buTT

oN

sN

oTe

s

1C

omm

unic

ate

Tran

smitt

er

with

Mot

or

a) P

ress

the

PRO

GR

AM b

utto

n on

the

head

of t

he

m

otor

The

mot

or w

ill os

cilla

te

b) I

mm

edia

tely

pre

ss a

nd h

old

the

UP

butto

n

on

the

rem

ote

The

mot

or w

ill os

cilla

te a

gain

. At t

his

time

the

mot

or a

nd re

mot

e ha

ve

been

join

ed

2C

hang

e Di

rect

ion

of M

otor

a) T

o ch

ange

mot

or ro

tatio

n pr

ess

and

hold

the

S

TOP

butto

n on

the

rem

ote.

The

mot

or w

ill os

cilla

te

b) T

hen

pres

s an

d ho

ld th

e D

OW

N b

utto

n

on

the

rem

ote

The

mot

or w

ill os

cilla

te a

gain

c) V

erify

cor

rect

rota

tion

-

seTT

iNG

Lim

iTs

FuN

cTi

oN

PRo

GRa

mm

abLe

FuN

cTio

NsT

ePs

Nee

DeD

/ TR

aN

smiT

TeR

buTT

oN

sN

oTe

s

3Se

t UPP

ER L

imit

a) M

ove

the

shad

e 3

to 4

” bel

ow th

e up

per l

imit

p

ositi

on p

ress

the

PRO

GR

AM b

utto

n, L

ocat

ed o

n

the

back

of t

he re

mot

e

The

mot

or w

ill os

cilla

te T

his

will

put t

he m

otor

in P

RO

GR

AM m

ode

NO

TE: T

he fi

rst l

imit

(UPP

ER L

IMIT

) can

not b

e er

ased

b) N

ow m

ove

the

shad

e up

to th

e de

sire

d lo

catio

n

a

nd p

ress

the

PRO

GR

AM b

utto

n ag

ain

The

mot

or w

ill os

cilla

te. T

he u

pper

lim

it is

now

set

4Se

t LO

WER

Lim

it

a) M

ove

the

shad

e do

wn

away

from

the

uppe

r

lim

it pr

evio

usly

set

, pre

ss th

e PR

OG

RAM

but

ton

The

mot

or w

il os

cilla

te. T

his

will

put t

he m

otor

in P

RO

GR

AM m

ode

b) N

ow m

ove

the

shad

e up

to th

e de

sire

d lo

catio

n of

the

low

er li

mit

and

pres

s th

e PR

OG

RAM

but

ton

agai

nTh

e m

otor

will

osci

llate

. The

low

er li

mit

is n

ow s

et

You

mus

t fol

low

thes

e ins

truct

ions

in th

e sam

e ord

er th

ey a

ppea

r on

this

shee

t oth

erwi

se th

e com

man

ds w

ill n

ot b

e abl

e to

be d

one

Page 70: Technical Catalog Celtic II (EN)

Vert

ilux

ceLT

ic ii

- Te

chni

cal c

atal

ogue

CEL

TIC

II-

Elec

troni

c Ba

ttery

Mot

or P

roga

mm

ing

Inst

ruct

ions

seTT

iNG

iNTe

RmeD

iaTe

s Li

miT

s

FuN

cTi

oN

PRo

GRam

mab

Le Fu

NcTi

oN

sTeP

s N

eeD

eD /

TRa

Nsm

iTTe

R bu

TTo

Ns

No

Tes

5Se

tting

Inte

rmed

iate

s St

ops

(UP

to 5

)

a) M

ove

the

shad

e aw

ay fr

om th

e pr

evio

usly

set

li

mit,

abo

ut 6

inch

es, p

ress

the

PRO

GR

AM b

utto

nTh

e m

otor

will

osci

llate

b) N

ow m

ove

the

shad

e to

the

desi

red

loca

tion

of th

e

in

term

edia

te S

top

and

pres

s th

e PR

OG

RAM

but

ton

aga

inTh

e m

otor

will

osci

llate

. The

inte

rmed

iate

lim

it is

now

set

Less

co

mm

oN

Fu

Nc

Tio

Ns

PRo

GRa

mm

abL

e Fu

Nc

Tio

NsT

ePs

Nee

DeD

/ TR

aN

smiT

TeR

buTT

oN

sN

oTe

s

Eras

ing

limits

a) M

ove

the

shad

e to

the

limit

you

wis

h to

era

se. P

ress

an

d ho

ld th

e PR

OG

RAM

but

ton

for a

ppro

xim

atel

y 7

seco

nds

The

mot

or w

ill os

cilla

te tw

ice,

at t

his

time

the

limit

has

been

era

sed

Con

nect

an

extra

Tra

smitt

er

a) P

ress

and

hol

d th

e ST

OP

butto

n on

the

Rem

ote

a

lread

y pr

ogra

med

for a

ppro

xim

atel

y 5

seco

nd

The

mot

or w

ill os

cilla

te

b) Im

med

iate

ly p

ress

the

UP

butto

n on

the

rem

ote

y

ou w

ish

to a

dd a

gain

.Th

e m

otor

will

osci

llate

. The

pro

gram

inst

ruct

ion

have

now

bee

n co

pied

to

the

new

rem

ote

Dele

te M

emor

y

a) P

ress

and

hol

d th

e PR

OG

RAM

but

ton

on th

e he

ad

of th

e m

otor

for 7

sec

onds

, (th

e m

otor

will

osci

llate

)ke

ep h

oldi

ng th

e bu

tton

anot

her 5

sec

onds

. (th

e m

otor

w

ill os

cilla

te tw

o m

ore

times

).

The

mem

ory

has

been

era

sed

from

the

mot

or

You

mus

t fol

low

thes

e ins

truct

ions

in th

e sam

e ord

er th

ey a

ppea

r on

this

shee

t oth

erwi

se th

e com

man

ds w

ill n

ot b

e abl

e to

be d

one

Page 71: Technical Catalog Celtic II (EN)

Vert

ilux

ceLT

ic ii

- Te

chni

cal c

atal

ogue

CEL

TIC

II-

RF &

Qui

et M

otor

s Ba

sic

Prog

amm

ing

Inst

ruct

ions

com

mo

N F

uN

cTi

oN

s

FuN

cTi

oN

PRo

GRa

mm

abL

e Fu

Nc

Tio

NsT

ePs

Nee

DeD

/ TR

aN

smiT

TeR

buTT

oN

sN

oTe

sso

uN

Ds

emiT

TeD

by

mo

ToR

1C

omm

unic

ate

Tran

smitt

er

with

Mot

or

a) D

isco

nnec

t the

mot

or-

-

b) P

ress

the

UP

for 2

sec

onds

& C

onne

ct M

otor

Con

nect

mot

or w

hile

pre

ssin

g th

e U

P bu

tton

Five

sho

rt 'b

eeps

'

c) P

ress

the

UP

butto

n (W

ithin

the

five

beep

s)W

ithin

the

five

beep

s yo

u m

ust r

elea

se th

e U

P bu

tton

and

pres

s it

agai

n on

ceTh

ree

shor

t 'be

eps'

2C

hang

e Di

rect

ion

of M

otor

a) H

old

the

STO

P bu

tton

Hol

d th

is b

utto

n un

til m

otor

em

its s

ound

Five

sho

rt 'b

eeps

'

b) P

ress

UP

butto

nIf

dire

ctio

n is

the

oppo

site

than

the

one

desi

red,

th

en re

peat

ste

p us

ing

the

DO

WN

but

ton

inst

ead

Thre

e sh

ort '

beep

s'

Less

co

mm

oN

Fu

Nc

Tio

Ns

FuN

cTi

oN

PRo

GRa

mm

abL

e Fu

Nc

Tio

NsT

ePs

Nee

DeD

/ TR

aN

smiT

TeR

buTT

oN

sN

oTe

sso

uN

Ds

emiT

TeD

by

mo

ToR

3C

onne

ct a

n ex

tra T

rans

mitt

er

a) O

n an

alre

ady

prog

ram

med

tran

smitt

er, p

ress

&

hold

: STO

PH

old

this

but

ton

until

mot

or e

mits

sou

ndFi

ve s

hort

'bee

ps'

b) O

n ne

w tr

ansm

itter

, pre

ss &

hol

d: U

PH

old

this

but

ton

until

mot

or e

mits

sou

ndTh

ree

shor

t ‘be

eps’

4De

lete

Mem

ory*

a) P

ress

the

STO

P bu

tton

Hol

d th

is b

utto

n un

til m

otor

em

its s

ound

Five

sho

rt ‘b

eeps

b) P

ress

the

PRO

GR

AM b

utto

n W

ithin

the

five

beep

sTh

ree

shor

t ‘be

eps’

5C

hang

e to

Jog

Mod

e an

d Vi

ce V

ersa

**

a) P

ress

the

STO

P bu

tton

Hol

d th

is b

utto

n un

til m

otor

em

its s

ound

Five

sho

rt ‘b

eeps

b) P

ress

the

STO

P bu

tton

agai

nW

ithin

the

five

beep

sTh

ree

shor

t ‘be

eps’

* T

his

is c

onve

nien

t whe

n th

ere

has

been

a p

rogr

amm

ing

mis

take

and

sta

rting

the

who

le p

rogr

amm

ing

is n

eede

d.

** “J

og M

ode”

mak

es th

e m

otor

mak

e a

shor

t mov

emen

t whe

n pr

essi

ng th

e up

or d

own

butto

ns. W

hen

in th

is m

ode,

to m

ake

the

mot

or m

ove

cont

inua

lly, t

he u

p or

do

wn

butto

n m

ust b

e pr

esse

d fo

r 3 s

econ

ds. T

he “j

og m

ode”

is c

onve

nien

t for

ven

etia

n bl

inds

(woo

d al

umin

um) s

ince

it a

llow

s til

ting

the

slat

s in

a m

ore

prec

ise

way

.

Page 72: Technical Catalog Celtic II (EN)

Vert

ilux

ceLT

ic ii

- Te

chni

cal c

atal

ogue

CEL

TIC

II-

Elec

troni

c M

otor

s Ba

sic

Prog

amm

ing

Inst

ruct

ions

com

mo

N F

uN

cTi

oN

s

Fu

Nc

Tio

NPR

oG

Ram

ma

bLe F

uN

cTi

oN

sTeP

s Nee

DeD

/ TRa

Nsm

iTTe

R bu

TTo

Ns

No

Tes

1C

omm

unic

ate

Tran

smitt

er

with

Mot

or

a) D

isco

nnec

t the

mot

or fo

r 10

seco

nds

-

b) C

onne

ct th

e m

otor

-

c) P

ress

UP

& D

OW

N a

t the

sam

e tim

ePr

ess

it un

til th

e m

otor

mov

es b

ack

& fo

rth

d) P

ress

the

PRO

GR

AM b

utto

nPr

ess

it co

ntin

uous

ly u

ntil

the

mot

or m

oves

bac

k &

forth

2C

hang

e Di

rect

ion

of M

otor

*

a) P

ress

the

UP

butto

nIf

mot

or g

oes

DO

WN

follo

w th

e st

ep “b

”, if

it go

es U

P, p

leas

e co

ntin

ue to

STE

P 3

b) P

ress

the

STO

P bu

tton

for 2

sec

onds

Pres

s it

until

the

mot

or m

oves

bac

k &

forth

c) D

isco

nnec

t the

mot

or-

seTT

iNG

Lim

iTs

FuN

cTi

oN

PRo

GRa

mm

abL

e Fu

Nc

Tio

NsT

ePs

Nee

DeD

/ TR

aN

smiT

TeR

buTT

oN

sN

oTe

s

3Se

t LO

WER

Lim

it

a) P

ress

DO

WN

& S

TOP

at th

e sa

me

time

The

mot

or w

ill go

DO

WN

con

tinuo

usly

b) W

hen

you

get t

o th

e ex

pect

ed p

ositi

on, p

ress

th

e ST

OP

butto

nIf

not a

t the

exp

ecte

d po

sitio

n, p

ress

the

UP

or th

e DO

WN

but

ton

to

adju

st th

e lim

it

c) W

hen

you

have

the

exac

t pos

ition

, pre

ss th

e ST

OP

butto

n ag

ain

Pres

s it

cont

inuo

usly

unt

il th

e m

otor

mov

es b

ack

& fo

rth. Y

our l

ower

lim

it ha

s be

en s

et

4Se

t UPP

ER L

imit

a) P

ress

the

PRO

GR

AM b

utto

n Th

e m

otor

will

mov

e ba

ck &

forth

(thi

s is

don

e to

let t

he s

hade

kno

w th

at

it is

cha

ngin

g di

rect

ion)

b) P

ress

UP

& ST

OP

at th

e sa

me

time

The

mot

or w

ill go

UP

cont

inuo

usly

c) W

hen

you

have

the

exac

t pos

ition

, pre

ss th

e ST

OP

butto

nIf

not a

t the

exp

ecte

d po

sitio

n, p

ress

the

UP

or th

e DO

WN

but

ton

to

adju

st th

e lim

it

Whe

n yo

u ha

ve th

e ex

act p

ositi

on, p

ress

the

STO

P bu

tton

agai

nPr

ess

it co

ntin

uous

ly u

ntil

the

mot

or m

oves

bac

k &

forth

. You

r upp

er li

mit

has

been

set

You

mus

t fol

low

thes

e ins

truct

ions

in th

e sam

e ord

er th

ey a

ppea

r on

this

shee

t oth

erwi

se th

e com

man

ds w

ill n

ot b

e abl

e to

be d

one

Page 73: Technical Catalog Celtic II (EN)

Vert

ilux

ceLT

ic ii

- Te

chni

cal c

atal

ogue

CEL

TIC

II-

Elec

troni

c M

otor

s Ba

sic

Prog

amm

ing

Inst

ruct

ions

seTT

iNG

Lim

iTs

FuN

cTi

oN

PRo

GRa

mm

abL

e Fu

Nc

Tio

NsT

ePs

Nee

DeD

/ TR

aN

smiT

TeR

buTT

oN

sN

oTe

s

5Ad

just

ing

the

Lim

its**

a) P

ress

all

the

way

UP

or a

l the

way

DO

WN

If yo

u no

tice

that

you

nee

d to

adj

ust t

he li

mits

, fol

low

nex

t ste

ps

b) P

ress

UP

& D

OW

N a

t the

sam

e tim

ePr

ess

it un

til th

e m

otor

mov

es b

ack

& fo

rth

c) P

ress

the

UP

or th

e D

OW

N b

utto

n to

adj

ust t

he li

mit

-

d) P

ress

STO

P Pr

ess

it un

til th

e m

otor

goe

s ba

ck &

forth

Less

co

mm

oN

Fu

Nc

Tio

Ns

PRo

GRa

mm

abL

e Fu

Nc

Tio

NsT

ePs

Nee

DeD

/ TR

aN

smiT

TeR

buTT

oN

sTh

e m

oTo

R w

iLL

mo

Ve b

ack

& F

oRT

h

Con

nect

an

extra

Tra

nsm

itter

On

the

seco

nd tr

ansm

itter

, pre

ss b

oth

UP

& D

OW

N

butto

ns a

t the

sam

e tim

eTh

e m

otor

will

mov

e ba

ck &

forth

Pres

s th

e PR

OG

RAM

but

ton

Dele

te M

emor

y***

Disc

onne

ct th

e m

otor

for 1

0 se

cond

s-

Con

nect

the

mot

or-

Pres

s bo

th U

P &

DO

WN

at t

he s

ame

time

Pres

s it

until

the

mot

or m

oves

bac

k &

forth

Pres

s PR

OG

RAM

but

ton

for 1

0 to

12

seco

nds

Pres

s it

until

the

mot

or m

oves

bac

k &

forth

aga

in

* A

fter p

rogr

amm

ing

chec

k th

e di

rect

ion,

if d

irect

ion

is re

vers

ed, c

hang

e it

as in

dica

ted.

If th

e di

rect

ion

is c

orre

ct; c

ontin

ue w

ith s

econ

d pr

ogra

mm

ing

step

. Cha

ngin

g

d

irect

ing

can

only

be

done

bef

ore

setti

ng th

e lim

its; a

lso

it ca

n on

ly b

e do

ne o

nce.

If y

ou n

eed

to d

o it

agai

n, y

ou w

ould

hav

e to

del

ete

and

star

t all

over

.

The

mot

or’s

pola

rity

is s

et fo

r the

mot

or to

be

on th

e le

ft by

def

ault.

If th

e m

otor

is o

n th

e rig

ht y

ou m

ust c

hang

e th

e di

rect

ion

first

** T

his

step

is u

sual

ly d

one

at th

e in

stal

latio

n si

te. A

fter s

ettin

g th

e lim

it po

sitio

ns, i

f the

lim

it is

a li

ttle

off a

t ins

talla

tion

site

, the

n yo

u ca

n do

this

ste

p.**

* Thi

s is

con

veni

ent w

hen

ther

e ha

s be

en a

pro

gram

min

g m

ista

ke a

nd s

tarti

ng th

e w

hole

pro

gram

min

g is

nee

ded.

Not

e: Y

ou m

ust f

ollo

w th

ese

inst

ruct

ions

in th

e sa

me

orde

r the

y ap

pear

on

this

she

et o

ther

wis

e th

e co

mm

ands

will

not b

e ab

le to

be

done

. You

MU

ST e

rase

and

sta

rt ov

er e

ach

time

you

mak

e a

mis

take

in th

e pr

ogra

mm

ing.

Page 74: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 75: Technical Catalog Celtic II (EN)

PROGRAMMING INSTRUCTIONS

RS232

Page 76: Technical Catalog Celtic II (EN)

THIS PAGE HAS BEEN

INTENTIONALLY LEFT BLANK

Page 77: Technical Catalog Celtic II (EN)

77 Vertilux CELTIC II - Technical Catalogue

CELTIC II - RS232 to RF Programming Instructions

Computer Controlled Radio Transmitter Manual

moDeL No. RaTeD VoLTaGe woRkiNG TemP woRkiNG cuRReNT LoaDiNG PoweR FReQueNcy chaNNeL No. oPeRaTioN moDe

AC117-01(Optional)

230VAC 50Hz120VAC 60Hz

0°C ≈ +70°C ≤ 20mA ≤ 20mW 433.92MHz 15 channel Computer Control/ manual

1- Specifications

2. Parameters

3. Wiring

4. Download and Install

Program button Antenna

Computer COM interface

Connect computers

RJ11

RJ11

Group control DOWN buttonGroup control STOP button

Group control UP button

AC POWER AC POWER AC POWER

1. Install AccessPort software from Performance Concepts webpage or CD-ROM o Run AccessPort.exe o Or extract AccessPort.rar to your desktop using WinRar then run AccessPort.exe2. Connect laptop to AC117 by first connecting USB-to-Serial adapter to Serial-to- RJ-11 adapter3. Provide 110VAC power to AC117 and Red LED will indicate that the device is powered up.

Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD

• Extendable antenna• Can daisy-chain (5) AC117-01 together• Multi-programmable operation• SMT machine assembly, damp proof enclosure

Page 78: Technical Catalog Celtic II (EN)

78 Vertilux CELTIC II - Technical Catalogue

CELTIC II - RS232 to RF Integration Device

78

4

3

5

12

6

5. OPTIONS

Fill control code in the textbox (Please reference UP code in the right control code list) Click on “Send”.

Fill control code in the textbox (Please reference STOP code in the right control code list) Click on “Send”.

Fill control code in the textbox (Please reference DOWN code in the right control code list) Click on “Send “.

UP

STOP

SETTING

DOWN

Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD

Page 79: Technical Catalog Celtic II (EN)

79 Vertilux CELTIC II - Technical Catalogue

CELTIC II - RS232 to RF Integration Device

1 3

After the shades and draperies have been installed and are working as you want them to with the correct channels on thevarious keypads/transmitters, reference these instructions so that you can pair the RS232-RF device to the shades and draperies:

Pairing the RS232-RF Device to a Roller Shade utilizing a laptop PC

1. Determine the UP control code channel you will use (e.g. FF 10 11 07 DD) and type that into the lower text box so that it is ready for you to click the SEND button

• CAUTION – Never assign the group control FF 10 11 00 DD in this step as doing so will prevent you from creating sub-groups.• The commands FF 10 11 00 DD, FF 10 11 00 CC, and FF 10 11 00 EE should only be used as master override channels (after pairing has been completed) and are never utilized during the pairing step.

2. Press and hold STOP button of the existing transmitter or keypad until you hear 5 beeps3. During the 5 beeps, send the correct UP control code (e.g. FF 10 11 07 DD) by clicking SEND4. If the RS232-RF signal was received by the roller shade motor, you will hear 3 beeps.5. Ensure that the RS232-RF device is working by sending UP, STOP, and DOWN control codes. If the device is not working properly, start over.

Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD

Page 80: Technical Catalog Celtic II (EN)

80 Vertilux CELTIC II - Technical Catalogue

CELTIC II - RS232 to RF Integration Device

Pairing the RS232-RF Device to a Drapery Track utilizing a laptop PC

1. Determine the STOP control code channel you will use (e.g. FF 10 11 09 CC) and type that intothe lower text box so that it is ready for you to click the SEND button2. Press and hold STOP the PROGRAMMING button on bottom of motor until the RED LED flashes3. While the RED LED is flashing, send the correct STOP control code (e.g. FF 10 11 09 CC) andwithin 5 seconds, SEND the correct UP control code (e.g. FF 10 11 09 DD) by changing the lasttwo letters of the string from CC to DD.

4. Ensure that the RS232-RF device is working by sending UP, STOP, and DOWN control codes. Ifthe device is not working properly, start over.

Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD

1 3

Page 81: Technical Catalog Celtic II (EN)

81 Vertilux CELTIC II - Technical Catalogue

CELTIC II - RS232 Interface Programming Codes

uP coNTRoL coDes:

GRouP coNTRoL FF 10 11 00 DD

1ST GROUP FF 10 11 01 DD 2ND GROUP FF 10 11 02 DD 3rd GROUP FF 10 11 03 DD 4th GROUP FF 10 11 04 DD 5th GROUP FF 10 11 05 DD 6th GROUP FF 10 11 06 DD 7th GROUP FF 10 11 07 DD 8th GROUP FF 10 11 08 DD 9th GROUP FF 10 11 09 DD 10th GROUP FF 10 11 0A DD 11th GROUP FF 10 11 0B DD 12th GROUP FF 10 11 0C DD 13th GROUP FF 10 11 0D DD 14th GROUP FF 10 11 0E DD 15th GROUP FF 10 11 0F DD

DowN coNTRoL coDes:

GRouP coNTRoL FF 10 11 00 ee

1ST GROUP FF 10 11 01 EE 2ND GROUP FF 10 11 02 EE 3rd GROUP FF 10 11 03 EE 4th GROUP FF 10 11 04 EE 5th GROUP FF 10 11 05 EE 6th GROUP FF 10 11 06 EE 7th GROUP FF 10 11 07 EE 8th GROUP FF 10 11 08 EE 9th GROUP FF 10 11 09 EE 10th GROUP FF 10 11 0A EE 11th GROUP FF 10 11 0B EE 12th GROUP FF 10 11 0C EE 13th GROUP FF 10 11 0D EE 14th GROUP FF 10 11 0E EE 15th GROUP FF 10 11 0F EE

sToP coNTRoL coDes:

GRouP coNTRoL FF 10 11 00 cc

1ST GROUP FF 10 11 01 CC 2ND GROUP FF 10 11 02 CC 3rd GROUP FF 10 11 03 CC 4th GROUP FF 10 11 04 CC 5th GROUP FF 10 11 05 CC 6th GROUP FF 10 11 06 CC 7th GROUP FF 10 11 07 CC 8th GROUP FF 10 11 08 CC 9th GROUP FF 10 11 09 CC 10th GROUP FF 10 11 0A CC 11th GROUP FF 10 11 0B CC 12th GROUP FF 10 11 0C CC 13th GROUP FF 10 11 0D CC 14th GROUP FF 10 11 0E CC 15th GROUP FF 10 11 0F CC

RS232 Interface Programming Codes

Page 82: Technical Catalog Celtic II (EN)

M I A M I . D A L L A S . L O S A N G E L E S

VERTILUX, L td .

Headquar ters : 7300NW35thTer race, Miami , F l , 33122

Phone: 1.800.356.8837 - Fax: 1.800.275.1719

www.verti lux.com

AUTHORIZEDDISTRIBUTOR: