NETAFIM USA Landscape & Turf Product Catalog | 7 TECHLINE ® DRIPLINE COMPARISON TECHLINE DRIPLINE COMPARISON CHART TECHLINE CV MAXIMUM UNIFORMITY See Pages 8-10 DIAMETER APPLICATION: TURF SHRUB & GROUND COVER INSTALLATION: SUBSURFACE ON-SURFACE AIR/VACUUM RELIEF VENT REQUIRED FOR SUBSURFACE? EMITTER SPACING: 6" 12" 18" 24" BUILT-IN CHECK VALVE ANTI-SIPHON EMITTER PRESSURE COMPENSATING CONTINUOUS SELF-FLUSHING EMITTERS MAXIMUM RECOMMENDED SYSTEM PRESSURE MINIMUM PRESSURE REQUIRED BENDING RADIUS QUALIFIES FOR LEED CREDIT USE WITH RECLAIMED WATER MAXIMUM LENGTH OF SINGLE LATERAL (FEET) @ 45 PSI, 18" EMITTER SPACING FLOW PER 100 FEET, 18" EMITTER SPACING (GPH) 0.26 0.4 0.6 0.9 Emitter Flow Rate (GPH) Tubing Color Dark Brown TECHLINE DL HIGH UNIFORMITY See Pages 11-12 0.26 0.4 0.6 0.9 Brown TECHLINE RW RECYCLED/RECLAIMED WATER See Pages 13-14 0.26 0.4 0.6 0.9 Brown with 2 Purple Stripes TECHLINE EZ SMALL & MEDIUM AREAS See Pages 15-16 0.26 0.4 0.6 0.9 Dark Brown *Note: Special Orders (S.O.) can be placed to accommodate custom spacing or other special considerations. Set-up charge, higher pricing and longer leadtimes may apply. 17mm Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes S.O.* Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes S.O.* Yes Yes Yes Yes 6 to 58 psi Yes Yes Yes Yes 58 psi 6 psi 7” Yes Yes Yes Yes Yes Yes Yes Yes 910 670 530 400 17.6 28.2 40.5 61.6 17mm Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No No S.O.* Yes Yes Yes Yes Yes Yes Yes Yes S.O.* S.O.* Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 14.5 to 58 psi Yes Yes Yes Yes 58 psi 14.5 psi 7” Yes Yes Yes Yes No 840 615 485 370 17.6 28.2 40.5 61.6 17mm Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes S.O.* Yes Yes Yes Yes Yes Yes Yes Yes S.O.* S.O.* Yes Yes No No No No Yes Yes Yes Yes 6 to 58 psi Yes Yes Yes Yes 58 psi 6 psi 7” Yes Yes Yes Yes No 1,020 750 595 450 17.6 28.2 40.5 61.6 12mm Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes S.O.* S.O.* Yes Yes Yes Yes Yes Yes Yes Yes S.O.* No No No No Yes Yes Yes Yes 6 to 58 psi Yes Yes Yes Yes 58 psi 6 psi 6” Yes Yes Yes Yes No No No No 535 390 340 310 17.6 28.2 40.5 61.6 DRIPLINES
3
Embed
TECHLINE DRIPLINE - 2M Company Home Page · PDF fileNETAFIM USA Landscape & Turf Product Catalog | 11 Large inlet filtration area (entire base of emitter) EXPLODED VIEW OF TECHLINE
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
NETAFIM USA Landscape & Turf Product Catalog | 7
TECHLINE® DRIPLINECOMPARISON
TECHLINE DRIPLINE COMPARISON CHART
TECHLINE CV
MAXIMUM UNIFORMITY
See Pages 8-10
DIAMETER
APPLICATION: TURF
SHRUB & GROUND COVER
INSTALLATION: SUBSURFACE
ON-SURFACE
AIR/VACUUM RELIEF VENTREQUIRED FOR SUBSURFACE?
EMITTER SPACING: 6"
12"
18"
24"
BUILT-IN CHECK VALVE
ANTI-SIPHON EMITTER
PRESSURE COMPENSATING
CONTINUOUS SELF-FLUSHING EMITTERS
MAXIMUM RECOMMENDED SYSTEM PRESSURE
MINIMUM PRESSURE REQUIRED
BENDING RADIUS
QUALIFIES FOR LEED CREDIT
USE WITH RECLAIMED WATER
MAXIMUM LENGTH OF SINGLE LATERAL (FEET) @ 45 PSI, 18" EMITTER SPACING
FLOW PER 100 FEET,18" EMITTER SPACING (GPH)
0.26 0.4 0.6 0.9Emitter Flow Rate (GPH)
Tubing Color Dark Brown
TECHLINE DL
HIGH UNIFORMITY
See Pages 11-12
0.26 0.4 0.6 0.9
Brown
TECHLINE RW
RECYCLED/RECLAIMED WATER
See Pages 13-14
0.26 0.4 0.6 0.9
Brown with 2 Purple Stripes
TECHLINE EZ
SMALL & MEDIUM AREAS
See Pages 15-16
0.26 0.4 0.6 0.9
Dark Brown
*Note: Special Orders (S.O.) can be placed to accommodate custom spacing or other special considerations. Set-up charge, higher pricing and longer leadtimes may apply.
17mm
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
S.O.*
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
S.O.*
Yes Yes Yes Yes
6 to 58 psi
Yes Yes Yes Yes
58 psi
6 psi
7”
Yes Yes Yes Yes
Yes Yes Yes Yes
910 670 530 400
17.6 28.2 40.5 61.6
17mm
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
No No No No
S.O.*
Yes Yes Yes Yes
Yes Yes Yes Yes
S.O.* S.O.* Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
14.5 to 58 psi
Yes Yes Yes Yes
58 psi
14.5 psi
7”
Yes Yes Yes Yes
No
840 615 485 370
17.6 28.2 40.5 61.6
17mm
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
S.O.*
Yes Yes Yes Yes
Yes Yes Yes Yes
S.O.* S.O.* Yes Yes
No No No No
Yes Yes Yes Yes
6 to 58 psi
Yes Yes Yes Yes
58 psi
6 psi
7”
Yes Yes Yes Yes
No
1,020 750 595 450
17.6 28.2 40.5 61.6
12mm
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes S.O.* S.O.*
Yes Yes Yes Yes
Yes Yes Yes Yes
S.O.*
No No No No
Yes Yes Yes Yes
6 to 58 psi
Yes Yes Yes Yes
58 psi
6 psi
6”
Yes Yes Yes Yes
No No No No
535 390 340 310
17.6 28.2 40.5 61.6
CONTROLLERS
WATER M
ETERSVALVES
FILTERSDRIPLIN
ESCON
TROLZON
E KITSDESIGN
INFORM
ATIONPOIN
T SOURCECOM
PONEN
TSREGULATIN
G
NETAFIM USA Landscape & Turf Product Catalog | 11
Large inlet filtration area (entire base of emitter)
EXPLODED VIEW OF TECHLINE CV EMITTER
Emitter outlet (top of emitter)
Diaphragm
Physical root barrier
Unique patented Turbonet Technology wide flow path allows more control of water flow and less chance for clogging
Check Valve (CV) mechanism
Anti-Vacuum mechanism prevents roots from penetrating the emitter and suction of dirt into the dripline
THE FIRST ANTI-SIPHON EMITTER IN LANDSCAPE DRIPLINEEmitter manufactured and successfully used in harsh agricultural applications since 2000. Emitter is pressure compensating and continuous flushing.
EMITTER WITH ANTI-SIPHON FEATUREPrevents ingestion of debris into tubing caused by vacuum.
FLEXIBLE UV RESISTANT TUBING Adapts to any planting area shape - tubing curves at a 7” radius. For on-surface installations withstands heat and direct sun.
QUALIFIES FOR USE ON LEED PROJECTS Contains the required quantity of post-consumer and post-industrial recycled material.
APPLICATIONS• Subsurface or on-surface installations• Curved, angular or narrow planting
areas• High traffic/high liability areas• Areas subject to vandalism• High wind areas• Turf, shrubs, trees• Slopes• At-grade windows• Sports turf
Limited Warranty for DriplinesNetafim warrants any polyethylene tubing and driplines (Techline® CV, Techline® DL, Techline® RW and Techline® EZ) sold to be free from environmental stress cracking for a period of seven (7) years from the date of original delivery.
Following these maximum spacing guidelines, emitter flow selection can be increased if desired by the designer.0.9 GPH flow rate available for areas requiring higher infiltration rates, such as coarse sandy soils.
On-surface or bury evenly throughoutthe zone to a maximum of 6”Bury evenly throughout the zone from 4”to 6” BURIAL DEPTH
Note: 0.4, 0.6 and 0.9 GPH are nominal flow rates. Actual flow rates used in the calculations are 0.42, 0.61 and 0.92 GPH.