1,00 1,05 1,10 1,15 1,20 1,25 1,30 1,35 0 15 25 38 50 63 80 12,7 Color code Fa daN Fc daN P Bar GR (Green) 25 (±5%) ≈ 32 50 BL (Blue) 50 (±5%) ≈ 65 100 RD (Red) 75 (±5%) ≈ 96 150 YW (Yellow) 90 (±5%) ≈ 116 175 (Other forces) 13 - 90 ≈ 16 - 116 25 - 175 Assembly possibilities Code Smax mm La mm Lc mm V l Kg TPA 20x13 12,7 79,4 66,7 0,004 0,11 TPA 20x15 15 86 71 0,005 0,12 TPA 20x25 25 104 79 0,007 0,13 TPA 20x38 38 130 92 0,009 0,15 TPA 20x50 50 154 104 0,012 0,16 TPA 20x63 63 180 117 0,014 0,18 TPA 20x80 80 214 134 0,017 0,20 TPA 20 Pressure medium Gas Nitrógeno (N 2 ) Max. charging pressure 175 Bar Min. charging pressure 25 Bar Rod seal area 0,50 cm 2 Operating temperature 0ºC - 80ºC Force increase by temperature 0,33 %/ºC Max. stem speed 1,6 m/s Maintenance kit Kit A20 Manufactured by TÉCNICAS APLICADAS DE PRESIÓN, S.L. · WWW.tecapres.com Force (daN) Pressure (Bar) Force (daN) Stroke (mm) Initial force/charging pressure ratio Ø20mm 90daN Force/stroke ratio Stroke (mm) Maximum strokes / minute (at 20ºC) i The black color code denotes a different pressure from that which the customer could choose when ordering between the minimum charging pressure (25Bar) and the maximum charging pressure (175Bar). If not otherwise specified, the gas spring will be supplied in the yellow code version. How to order Model Stroke Color code 0 10 20 30 40 50 60 70 80 90 100 25 50 75 100 125 150 175 79 75 60 48 40 34 29 10 20 30 40 50 60 70 80 90 15 25 38 50 63 80 12,7 Ø20 2/3 Lc min +1.0 +0.5 FP 20 TPA 20 GR 15 x 3.5 3 Ø15 Ø20 Color code max Lc S La Ø8 17 r 1 ±0.25 1 ±0.1 Gas charging M6(8mm) TPFV3 valve M6-C adapter 230 PED 2014/68/UE Maximum recommended 90% stroke TPGAS 07 01-2018 Strokes/min (spm) VDI SAFETY i MICRO TITAN TPH TPS TPSP TPF TPK TPC TPCT TPB TPR TPA TPG TECAPRES ®