Jurijs Pavlovics Michael Ward Tim Corrighan _BIMCampus Revit 2014 Autumn 2013 M echanical E lectrical + P lumbing
May 24, 2015
Jurijs PavlovicsMichael WardTim Corrighan
_BIMCampusRevit 2014
Autumn 2013
M echanicalE lectrical +P lumbing
IntroductionBrief
Our team has been appointed to design a new office specifically tailored to legal firms and legal training. The building must incorporate space for multiple companies.
Schedule of Accommodation:
Office spaces (both open plan and cellular)
Meeting/board rooms (varying sizes for specific uses, eg. 1 to 1, groups, etc.)
Achieve storage room
General storage rooms
Moot court (legal training court)
Break-out spaces throughout the building
Kitchenette/coffee points
Toilets (male,female, accessible WC’s, shower room, etc.)
Accessible lift
Cleaners store
Central reception with guest waiting area
M echanicalE lectrical +P lumbing
SiteProposed Site
The proposed site is located on the North bank of the River Tyne, Newcastle upon Tyne.
57 QuaysideNewcastle upon TyneNE1 2BJ
Currently housing a ‘Pocket Park’, an initiative promoted by NE1
M echanicalE lectrical +P lumbing
Site ConstraintsSite Boundaries
The site is restricted on two sides by neighbouring buildings:
Flynn’s Bar
Law Building
To the front, the site is restricted by the street front and public footpath
To the rear, the site is slight more open with room for car parking
All buildings are limited to roughly the same height and number of levels
Observations
Busy street to the South
Access needed to property along the East boundary
Access to car park from Broad Chare to the North East
M echanicalE lectrical +P lumbing
InspirationPresidents
Stone + Brick
Facades
Quayside History
Glass with hard materials
Infill Architecture
Modern Architecture sitting with Classical
M echanicalE lectrical +P lumbing
Using the 3D City ModelCity Model
Throughout this project and the last we have used a 3D city model of Newcastle to create the context for our Revit model.
Used to better understand the site boundaries.
We have used the 3D city model to create more professional external renders.
The 3D model was used to align the point cloud data to one of the neighbouring buildings so a Revit model for these buildings could be modelled in place.
M echanicalE lectrical +P lumbing
Data AcquisitionLaser Scanning
Tutorial in laser scanning with Paul from Leica Geosystems.
Scanned the full site from several different locations
We headed straight back to the computer suit to load the point cloud into Revit
M echanicalE lectrical +P lumbing
Laser Scanning and Modelling from the Point Cloud DataModelling from Point Cloud Data
The point cloud data was opened in a new revit project and was used to begin building a model of the adjoining buildings to the site.
Using walls, extrusions and windows we created the facades of the buildings.
We created custom texture to apply to these surfaces.
We then added roofs and further details to complete the context models.
We worked individually on each of the buildings and the models were linked together before being imported and aligned to the site model.
M echanicalE lectrical +P lumbing
DN
By Department LegendLift
Offices
Private
Public
WC
Drawn
Dwg. No.
Scale at A1
Project No.
Drawing
Project
Status
Rev.
Date
this drawing is copyright - check all dimensions on site - inform architect / so of any discrepancies - work to figured dimensions only - do not scale
Rev. Amendment Date
Checked 1 : 100
1234 A(00)GAP900
MW
Departmental Plans
1234 - BCT2 - 57 Quayside
Preliminary
09/11/13Checker
1 : 100Departmental Level 001
1 : 100Departmental Level 02
1 : 100Departmental Level 13
1 : 100Departmental Level 24
1 : 100Departmental Level 35
The DesignM echanicalE lectrical +P lumbing
Architectural ModelModelling in Revit
We all began modelling the architecture model to create a com-prehensive mass made up of architectural elements:
Walls (with materials)
Floors
Doors
Windows and other glazing
This is the base for the BIM
M echanicalE lectrical +P lumbing
Structural ModelStructural Grid
8x5 grid
Horizontal Spacing - 3000/2000/4200/2000/3000
Vertical Spacing - 4000/2000/2000/6000/6000/5000/2500
Base of steel frame
Primary Structure
Steel Frame
In-situe cast concrete floor
Concrete pile foundations
M echanicalE lectrical +P lumbing
MEP ModelLighting
150mm alound in ceiling void for recessed lighting
Whitecroft Softlighter - 500 lux
Spaced 2.4 m
Ventilation and Heating and Cooling
Duct work - rectangular 400x250 - circular 250 diameter/150 diameter
Extract Grill
Daikin FXFQ-M-12-36-MBH
Each unit 2.1kW cooling
Open plan office - 70-100W/m2. FCU’s between 40-50 m2
M echanicalE lectrical +P lumbing
What is Next?Navisworks
We will then import a central model into Autodesk’s Navisworks. Here we will run a series of clash detections between the architectural and structural models, architecture and MEP and structure with MEP.
In Navisworks we will also create a series of construction animations and renders using the cloud.
We welcome any questions?
M echanicalE lectrical +P lumbing