Top Banner
TECHNICAL DATA SHEET Americas +1 336 996 7046 | EMEA +31 88 1307 410 | Philippines +63 49 543 0241 | China +86 0512 6303 3700 www.texwipe.com *Test Methods 1 – “Evaluating Wiping Materials Used in Cleanroom and Other Controlled Environments,” IEST-RP-CC004.3, Institute for Environmental Sciences and Technology, Rolling Meadows, IL, 2004; www.iest.org. 2 – E2090-12, “Standard Test Method for Size-Differentiated Counting of Particles and Fibers Released from Cleanroom Wipers Using Optical and Scanning Electron Microscopy,” ASTM International, West Conshohocken, PA, 2012; www.astm.org. TM – Refers to Texwipe Test Method – available upon request. Contact Texwipe Customer Service at www.texwipe.com or [email protected] for a copy. Note: The data in this table represent typical analyses. For non-sterile products: TX8691 – filled using Semiconductor grade IPA Texwipe holds ISO 9001 and ISO 14001 registrations. All Texwipe products conform to GHS classification for labeling (where applicable). Shipping classification based on weight of inner package. Performance Characteristics Property Typical Value Test Method* Particles and Fibers LPC: 0.5 μm Particles: 0.5-5.0 μm Particles: 5.0-100 μm Fibers: >100 μm 2.9 x 10 6 particles/m 2 1.7 x 10 6 particles/m 2 37,000 particles/m 2 100 fibers/m 2 1, TM20 2, TM22 Nonvolatile Residue IPA extractant DIW extractant 0.02 g/m 2 0.003 g/m 2 1, TM1 1, TM1 Ions Sodium Potassium Chloride 0.04 ppm 0.04 ppm 0.009 ppm 1, TM18 1, TM18 1, TM18 Physical Characteristics Property Typical Value Test Method* Absorbency Sorptive capacity Sorptive rate 320 mL/m 2 0.5 second 1, TM20 1, TM20 Basis Weight 130 g/m 2 1, TM20 Cleanroom Wipers Vectra ® LT TEX-LIT-TDS-029 Rev.00-02/17 Americas +1 336 996 7046 | EMEA +31 88 1307 410 | Philippines +63 49 543 0241 | China +86 0512 6303 3700 www.texwipe.com Custom products available upon request. TECHNICAL DATA SHEET Vectra ® LT Dry | Pre-Wetted www.texwipe.com
2

TDS Vectra 10LT 2017 CuR1 - Texwipe · TX8691 – fi lled using Semiconductor grade IPA Texwipe holds ISO 9001 and ISO 14001 registrations. All Texwipe products conform to GHS classifi

Aug 07, 2019

Download

Documents

lediep
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: TDS Vectra 10LT 2017 CuR1 - Texwipe · TX8691 – fi lled using Semiconductor grade IPA Texwipe holds ISO 9001 and ISO 14001 registrations. All Texwipe products conform to GHS classifi

T E C H N I C A L D A T A S H E E T

Americas +1 336 996 7046 | EMEA +31 88 1307 410 | Philippines +63 49 543 0241 | China +86 0512 6303 3700 www.texwipe.com

*Test Methods1 – “Evaluating Wiping Materials Used in Cleanroom and Other Controlled Environments,” IEST-RP-CC004.3, Institute for Environmental Sciences

and Technology, Rolling Meadows, IL, 2004; www.iest.org.

2 – E2090-12, “Standard Test Method for Size-Differentiated Counting of Particles and Fibers Released from Cleanroom Wipers Using Optical and Scanning Electron Microscopy,” ASTM International, West Conshohocken, PA, 2012; www.astm.org.

TM – Refers to Texwipe Test Method – available upon request. Contact Texwipe Customer Service at www.texwipe.com or [email protected] for a copy.

Note: The data in this table represent typical analyses.

For non-sterile products:

TX8691 – fi lled using Semiconductor grade IPA

Texwipe holds ISO 9001 and ISO 14001 registrations.

All Texwipe products conform to GHS classifi cation for labeling (where applicable).Shipping classifi cation based on weight of inner package.

Performance CharacteristicsProperty Typical Value Test Method*

Particles and FibersLPC: ≥0.5 µmParticles: 0.5-5.0 µmParticles: 5.0-100 µmFibers: >100 µm

2.9 x 106 particles/m2

1.7 x 106 particles/m2

37,000 particles/m2

100 fi bers/m2

1, TM20 2, TM22

Nonvolatile ResidueIPA extractantDIW extractant

0.02 g/m2

0.003 g/m2

1, TM11, TM1

IonsSodiumPotassiumChloride

0.04 ppm0.04 ppm0.009 ppm

1, TM181, TM181, TM18

Physical CharacteristicsProperty Typical Value Test Method*

AbsorbencySorptive capacitySorptive rate

320 mL/m2

0.5 second1, TM201, TM20

Basis Weight 130 g/m2 1, TM20

Cleanroom Wipers Vectra® LT

TEX-

LIT-

TDS-

029

Rev.0

0-02

/17

Americas +1 336 996 7046 | EMEA +31 88 1307 410 | Philippines +63 49 543 0241 | China +86 0512 6303 3700 www.texwipe.com

Custom products available upon request.

T E C H N I C A L D A T A S H E E T

Vect

ra®

LTDr

y |

Pre

-Wet

ted

www.texwipe.com

Page 2: TDS Vectra 10LT 2017 CuR1 - Texwipe · TX8691 – fi lled using Semiconductor grade IPA Texwipe holds ISO 9001 and ISO 14001 registrations. All Texwipe products conform to GHS classifi

Americas +1 336 996 7046 | EMEA +31 88 1307 410 | Philippines +63 49 543 0241 | China +86 0512 6303 3700 www.texwipe.com

T E C H N I C A L D A T A S H E E T

Made in USAM d i USA

ProductsNumber Description Sterile Packaging Case

Dry Wipers – Vectra® Alpha® 10 LT

TX8659 9" x 9" (23 cm x 23 cm) dry 150 wipers/bag (2 inner bags of 75) 10 bags

Pre-Wetted Wipers – Vectra® QuanSat™ LT

TX8691 9" x 9" (23 cm x 23 cm) pre-wetted with 6% IPA 50 wipers/bag 12 bags

Cleanroom Wipers Vectra® LT

Vertex® Alpha® 10 LT (top)T Vectra® QuanSat™ LT (bottom)T

Vectra® Alpha® 10 LT / Vectra® QuanSat™ LT

100% polyester

Americas +1 336 996 7046 | EMEA +31 88 1307 410 | Philippines +63 49 543 0241 | China +86 0512 6303 3700 www.texwipe.com

Custom products available upon request.

T E C H N I C A L D A T A S H E E TT E C H N I C A L D A T A S H E E T

Cleanroom Wipers Vectra® LT

DescriptionVectra® Alpha® 10 LT and Vectra® QuanSat™LT is made from a low titanium dioxide (TiO2) 100% polyester, processed on Texwipe’s automated cleaning system.

Vectra® advances the cleaning process and brings this technology to a higher level of wiper manufacturing.

Applications• Use where titanium dioxide may impact the process

or product.

• Wiping and cleaning surfaces, equipment and parts.

• Applying and removing lubricants, adhesives, residues and other solutions including disinfectants.

• Cleaning with solvents such as isopropyl alcohol (IPA), ethanol, acetone, and degreasers.

• Lining trays for holding, protecting, drying and storing of parts, equipment and devices.

• Appropriate for use with temperatures less than 400°F (205°C).

Industries

Aerospace Animal Laboratory Biologics

Cleanroom Design/Build

Compounding Pharmacies Data Storage

Facilities Maintenance Industrial Laboratory

Medical Device Microelectronics Pharmaceutical

Printing/Graphics Semiconductor

Features & Benefi ts• Designed with a low level of titanium dioxide (TiO2), safe for

processes that are affected by the presence of TiO2. The presence of TiO2 may leave an additional residue.

• Vectra® sealed border technology provides low levels of ions, NVRs (non-volatile residues), particles and fi bers for use in critical cleaning applications and environments.

• Designed for use on abrasive surfaces. This wiper will not easily snag or abrade releasing particles and fi bers intothe process or environment.

• Excellent chemical resistance for compatibility with a variety of solutions.

• Vectra® QuanSat™ LT is pre-wetted with 0.2 µm fi ltered 6% IPA / 94% DIW for ease of use.

• Vectra® QuanSat™ LT wipers are packaged in easy-to-use recloseable slider bags reducing solution evaporation that preserves the consistent wiper wetness level.

• Autoclave safe (dry wipers only).

• Individually lot coded for ease of traceability and quality control.

Cleanroom Environment• ISO Class 1 – 6

• Class <1 – 1,000

• EU Grade A – D

Shelf Life• Non-Sterile (Dry) – 5 years from date of manufacture

• Non-Sterile (Pre-Wetted) – TX8691: 1 year from date of manufacture