T0 vacuum system Central tank Central pumping Coupling of 2 girders UHV tests not achieved No damping material 15/07/20153
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: TBM Vacuum considerations Alex Vamvakas 15/07/2015.

TBM Vacuum considerations

Alex Vamvakas15/07/2015

Page 2: TBM Vacuum considerations Alex Vamvakas 15/07/2015.

2

Outline• Existing system• Proposed changes• Points to be discussed

15/07/2015

Page 3: TBM Vacuum considerations Alex Vamvakas 15/07/2015.

3

T0 vacuum systemCentral tank• Central pumping• Coupling of 2 girders• UHV tests not achieved• No damping material

15/07/2015

Page 4: TBM Vacuum considerations Alex Vamvakas 15/07/2015.

4

Decoupling of the two girders:

• Mini pumps on PETS and SAS

• Independent vacuum tank for MB

• Similar configuration tested in CLEX

New vacuum system proposal

15/07/2015

Page 5: TBM Vacuum considerations Alex Vamvakas 15/07/2015.

5

Mini pumps on PETS and SAS

Considerations:

• Number of pumps (2/PETS,SAS)

• Supports

• Heat transfer to PETS and SAS (pumps power?)

• Reducing flanges

15/07/2015

Page 6: TBM Vacuum considerations Alex Vamvakas 15/07/2015.

6

Mini pump on T1 PETS

Rotate PETS vacuum chamber by 90o:

• Possible, as PETS not yet fabricated

• No support needed

Considerations:

• Vertical position OK?

• Very tight clearance with PETS core, offset needed?

15/07/2015

Page 7: TBM Vacuum considerations Alex Vamvakas 15/07/2015.

7

MB Vacuum network T0.2Considerations:

• 2 pumps enough?

• Ports for external pumping, sensors

15/07/2015

Page 8: TBM Vacuum considerations Alex Vamvakas 15/07/2015.

8

MB Vacuum network T1Considerations:

• 2 pumps enough?

• Ports for external pumping, sensors

15/07/2015

Page 9: TBM Vacuum considerations Alex Vamvakas 15/07/2015.

9

Vacuum networkConsiderations:• Tubing dimensions• Forces on SAS• Bellows necessary?

• Total weight per waveguide:2kg per load1kg from tank assembly

15/07/2015

Page 10: TBM Vacuum considerations Alex Vamvakas 15/07/2015.

10

General comments• Pumps control:

• Power• DAQ• Interconnection with thermal/alignment measurements

• Pumps vibration• Isolation required?

• Next steps?

15/07/2015