IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018
237

Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Oct 20, 2018

Download

Documents

lethu
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

IEC-line by OVERDIGIT overdigit.com

Target CoDeSys

Reference Manual update: 13-04-2018

Page 2: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

1

Table of Contents 1. Target libraries.......................................................................................................................................................... 7

1.1 The SysLibCom library (SysLibCom.lib) ............................................................................................................... 8

1.1.1 SysComFlush ................................................................................................................................................ 9

1.1.2 SysComPurge ............................................................................................................................................. 10

1.1.3 SysComReadLine........................................................................................................................................ 11

1.1.4 SysComRxNum ........................................................................................................................................... 12

1.2 The SysLibSockets library (SysLibSockets.lib) ................................................................................................... 13

1.2.1 TYPE INADDR ............................................................................................................................................. 14

1.2.2 TYPE SOCK_IP_MREQ ................................................................................................................................ 15

1.2.3 TYPE SOCKADDRESS .................................................................................................................................. 16

1.2.4 TYPE SOCKET_FD_SET ................................................................................................................................ 17

1.2.5 TYPE SOCKET_LINGER ................................................................................................................................ 18

1.2.6 TYPE SOCKET_TIMEVAL ............................................................................................................................. 19

1.2.7 SysSockAccept ........................................................................................................................................... 20

1.2.8 SysSockBind ............................................................................................................................................... 21

1.2.9 SysSockClose .............................................................................................................................................. 22

1.2.10 SysSockConnect ....................................................................................................................................... 23

1.2.11 SysSockCreate .......................................................................................................................................... 24

1.2.12 SysSockGetHostByName ......................................................................................................................... 25

1.2.13 SysSockGetHostName ............................................................................................................................. 26

1.2.14 SysSockGetLastErrorSync ........................................................................................................................ 27

1.2.15 SysSockGetOption ................................................................................................................................... 29

1.2.16 SysSockHtonl ........................................................................................................................................... 30

1.2.17 SysSockHtons ........................................................................................................................................... 31

1.2.18 SysSockInetAddr ...................................................................................................................................... 32

1.2.19 SysSockInetNtoa ...................................................................................................................................... 33

1.2.20 SysSockIoctl ............................................................................................................................................. 34

1.2.21 SysSockListen ........................................................................................................................................... 36

1.2.22 SysSockNtohl ........................................................................................................................................... 37

1.2.23 SysSockNtohs ........................................................................................................................................... 38

1.2.24 SysSockRecv ............................................................................................................................................. 39

1.2.25 SysSockRecvFrom .................................................................................................................................... 40

1.2.26 SysSockSelect ........................................................................................................................................... 41

Page 3: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

2

1.2.27 SysSockSend ............................................................................................................................................ 42

1.2.28 SysSockSendTo ........................................................................................................................................ 43

1.2.29 SysSockSetIPAddress ............................................................................................................................... 44

1.2.30 SysSockSetOption .................................................................................................................................... 45

1.2.31 SysSockShutdown .................................................................................................................................... 46

1.3 The RTOS functions library (rtos.lib) ................................................................................................................ 47

1.3.1 TYPE MSG_EX ............................................................................................................................................ 48

1.3.2 RtosCreateMsg .......................................................................................................................................... 49

1.3.3 RtosDeleteMsg .......................................................................................................................................... 50

1.3.4 RtosDhcpUse ............................................................................................................................................. 51

1.3.5 RtosFindMsg .............................................................................................................................................. 52

1.3.6 RtosGetBootstrapVersion .......................................................................................................................... 53

1.3.7 RtosGetDevicenames ................................................................................................................................ 54

1.3.8 RtosGetDhcpStat ....................................................................................................................................... 55

1.3.9 RtosGetIniEntry ......................................................................................................................................... 56

1.3.10 RtosGetIniEntryEx .................................................................................................................................... 57

1.3.11 RtosGetLinkstate ..................................................................................................................................... 58

1.3.12 RtosGetMacAddress ................................................................................................................................ 59

1.3.13 RtosGetMsg ............................................................................................................................................. 60

1.3.14 RtosGetRebootReason ............................................................................................................................ 61

1.3.15 RtosGetTick_us ........................................................................................................................................ 62

1.3.16 RtosGetVersion ........................................................................................................................................ 63

1.3.17 RtosGetVersionString .............................................................................................................................. 64

1.3.18 RtosIpconfig ............................................................................................................................................. 65

1.3.19 RtosReboot .............................................................................................................................................. 66

1.3.20 RtosSendMsg ........................................................................................................................................... 67

1.3.21 RtosServers .............................................................................................................................................. 68

1.3.22 RtosSetIniEntry ........................................................................................................................................ 69

1.3.23 RtosSetIniEntryEx .................................................................................................................................... 70

1.4 The SysLibEvent library (SysLibEvent.lib) ......................................................................................................... 71

1.4.1 SysEventCreate .......................................................................................................................................... 72

1.4.2 SysEventDelete .......................................................................................................................................... 73

1.4.3 SysEventSet ............................................................................................................................................... 74

1.4.4 SysEventWait ............................................................................................................................................. 75

1.5 The SysLibCallback library (SysLibCallback.lib) ................................................................................................. 76

1.6 The SysLibDir library (SysLibDir.lib) .................................................................................................................. 77

Page 4: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

3

1.7 The SysLibPlcCtrl library (SysLibPlcCtrl.lib) ....................................................................................................... 78

1.8 The SysLibStr library (SysLibStr.lib) ................................................................................................................... 79

1.9 The FRAM library (FRAM_Lib.lib) ..................................................................................................................... 80

1.9.1 FRAM_Read ............................................................................................................................................... 81

1.9.2 FRAM_Write .............................................................................................................................................. 82

1.10 The RTC library (RTC_Lib.lib) .......................................................................................................................... 83

1.10.1 DateTime_Read ....................................................................................................................................... 84

1.10.2 RTC_Read ................................................................................................................................................. 85

1.10.3 RTC_Write................................................................................................................................................ 86

1.11 The MODEM library (MODEM_Lib.lib) ........................................................................................................... 87

1.11.1 DYNDNS_STATUS ..................................................................................................................................... 88

1.11.2 MODEM_CHAR_SET ................................................................................................................................ 89

1.11.3 MODEM_COMMAND .............................................................................................................................. 90

1.11.4 MODEM_DATA_SERVICE ......................................................................................................................... 91

1.11.5 MODEM_STATUS ..................................................................................................................................... 92

1.11.6 DynDNS_Client ........................................................................................................................................ 95

1.11.7 GM01_PPP ............................................................................................................................................... 97

1.11.8 GM01_PPP_SMS_Call ............................................................................................................................ 100

1.11.9 GM01_SMS ............................................................................................................................................ 105

1.12 The TCPIP library (TCPIP_Lib.lib) .................................................................................................................. 108

1.12.1 FTP_COMMAND .................................................................................................................................... 109

1.12.2 HTTP_MODE .......................................................................................................................................... 110

1.12.3 TCPIP_ERROR ......................................................................................................................................... 111

1.12.4 DNS_Client ............................................................................................................................................. 120

1.12.5 FTP_Client .............................................................................................................................................. 122

1.12.6 HTTP_Client ........................................................................................................................................... 125

1.12.7 HTTP_Get ............................................................................................................................................... 128

1.12.8 HTTP_Post ............................................................................................................................................. 130

1.12.9 SendMail ................................................................................................................................................ 132

1.12.10 SendPing .............................................................................................................................................. 134

1.12.11 SMTP_Client ........................................................................................................................................ 136

1.12.12 SNTP_DateTime ................................................................................................................................... 139

1.13 The MySQL library (MySQL_Lib.lib) .............................................................................................................. 140

1.13.1 MySQL_Connect_Set ............................................................................................................................. 141

1.13.2 MySQL_Data_Seek ................................................................................................................................ 142

1.13.3 MySQL_Database_Set ........................................................................................................................... 143

Page 5: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

4

1.13.4 MySQL_Fetch_Row................................................................................................................................ 144

1.13.5 MySQL_Field_Len .................................................................................................................................. 145

1.13.6 MySQL_Field_Name .............................................................................................................................. 146

1.13.7 MySQL_Num_Fields .............................................................................................................................. 147

1.13.8 MySQL_Num_Rows ............................................................................................................................... 148

1.13.9 MySQL_Query ........................................................................................................................................ 149

1.13.10 MySQL_Result ..................................................................................................................................... 150

1.14 The RS485/Serial library (rs485.lib) .............................................................................................................. 151

1.14.1 TYPE RS485_BREAK ............................................................................................................................... 152

1.14.2 TYPE RS485_FLOWCTRL ........................................................................................................................ 153

1.14.3 TYPE RS485_MODE ................................................................................................................................ 154

1.14.4 TYPE RS485_PARITY ............................................................................................................................... 155

1.14.5 TYPE RS485_PORTS ............................................................................................................................... 156

1.14.6 Rs485ComClose ..................................................................................................................................... 157

1.14.7 Rs485ComOpen ..................................................................................................................................... 158

1.14.8 Rs485FlushOutput ................................................................................................................................. 159

1.14.9 Rs485GetStatus ..................................................................................................................................... 160

1.14.10 Rs485IsByteAvailable........................................................................................................................... 161

1.14.11 Rs485PurgeInput ................................................................................................................................. 162

1.14.12 Rs485PurgeOutput .............................................................................................................................. 163

1.14.13 Rs485ReceiveBlock .............................................................................................................................. 164

1.14.14 Rs485ReceiveByte ............................................................................................................................... 165

1.14.15 Rs485SendBlock .................................................................................................................................. 166

1.14.16 Rs485SendBreak .................................................................................................................................. 167

1.14.17 Rs485SendByte .................................................................................................................................... 168

1.14.18 Rs485SetFlowcontrol ........................................................................................................................... 169

1.14.19 Rs485SetMode .................................................................................................................................... 170

1.15 The RS485/Expansion library (RS485_Lib.lib) ............................................................................................... 171

1.15.1 DMX512_Tx ........................................................................................................................................... 172

1.15.2 RS485_Init_A ......................................................................................................................................... 173

1.15.3 RS485_Tx_Rx_A ..................................................................................................................................... 174

1.16 The MODBUS library (MODBUS_Lib.lib) ....................................................................................................... 175

1.16.1 MB_RTU_PARITY ................................................................................................................................... 176

1.16.2 MODBUS_STATUS ................................................................................................................................. 178

1.16.3 MB_RTU_Deinit ..................................................................................................................................... 179

1.16.4 MB_RTU_Init ......................................................................................................................................... 180

Page 6: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

5

1.16.5 MB_RTU_Rd_Coils ................................................................................................................................. 181

1.16.6 MB_RTU_Rd_Hold_Regs ....................................................................................................................... 182

1.16.7 MB_RTU_Rd_Input_Regs ...................................................................................................................... 183

1.16.8 MB_RTU_Rd_Inputs .............................................................................................................................. 184

1.16.9 MB_RTU_Req_Rsp ................................................................................................................................. 185

1.16.10 MB_RTU_Wr_Coils .............................................................................................................................. 187

1.16.11 MB_RTU_Wr_Hold_Regs ..................................................................................................................... 188

1.16.12 MB_RTU_Wr_Rd_Hold_Regs .............................................................................................................. 189

1.16.13 MB_RTU_Wr_Single_Coil .................................................................................................................... 191

1.16.14 MB_RTU_Wr_Single_Reg .................................................................................................................... 192

1.16.15 MB_RTU_Slave .................................................................................................................................... 193

1.16.16 MB_TCP_Connect ................................................................................................................................ 196

1.16.17 MB_TCP_Disconnect ........................................................................................................................... 198

1.16.18 MB_TCP_Rd_Coils ............................................................................................................................... 199

1.16.19 MB_TCP_Rd_Hold_Regs ...................................................................................................................... 200

1.16.20 MB_TCP_Rd_Input_Regs ..................................................................................................................... 201

1.16.21 MB_TCP_Rd_Inputs ............................................................................................................................. 202

1.16.22 MB_TCP_Req_Rsp ............................................................................................................................... 203

1.16.23 MB_TCP_Wr_Coils ............................................................................................................................... 206

1.16.24 MB_TCP_Wr_Hold_Regs ..................................................................................................................... 207

1.16.25 MB_TCP_Wr_Rd_Hold_Regs ............................................................................................................... 208

1.16.26 MB_TCP_Wr_Single_Coil ..................................................................................................................... 210

1.16.27 MB_TCP_Wr_Single_Reg ..................................................................................................................... 211

1.16.28 MB_TCP_Server ................................................................................................................................... 212

1.16.29 MB_Swap_Dword ................................................................................................................................ 215

1.16.30 MB_Swap_Dword2 .............................................................................................................................. 216

1.16.31 MB_Swap_Word.................................................................................................................................. 217

2. PLC Browser Commands ....................................................................................................................................... 218

2.1 DHCP ............................................................................................................................................................... 219

2.2 DNSNAME ....................................................................................................................................................... 220

2.3 FTPPASSWORD ............................................................................................................................................... 221

2.4 FTPUSER .......................................................................................................................................................... 222

2.5 GATEWAY ....................................................................................................................................................... 223

2.6 GETDATETIME ................................................................................................................................................. 224

2.7 IP ..................................................................................................................................................................... 225

2.8 IPCFG .............................................................................................................................................................. 226

Page 7: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

6

2.9 IPETH .............................................................................................................................................................. 227

2.10 NETMASK ...................................................................................................................................................... 228

2.11 PING .............................................................................................................................................................. 229

2.12 REBOOT ........................................................................................................................................................ 230

2.13 SETDATETIME ............................................................................................................................................... 231

2.14 TCPIPMEM .................................................................................................................................................... 232

2.15 VER................................................................................................................................................................ 233

2.16 WEBPASSWORD ........................................................................................................................................... 234

2.17 WEBUSER ...................................................................................................................................................... 235

3. Error handling ....................................................................................................................................................... 236

Page 8: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

7

1. Target libraries

The libraries below provide access to the special hardware and software functionalities of the specific target. They are implemented on the

target system and can be used by the CoDeSys project. In simulation mode the target system is not reachable. To allow running a CoDeSys

project which uses these libraries in simulation mode, there will be dummy functions called instead. These dummy functions return a neutral

value, e.g. "nothing received" for "SysComRecv", "Sending successfull" for "SysComSend".

The following libraries are available:

The RS485/Serial library (rs485.lib)

The SysLibCom library (SysLibCom.lib)

The SysLibSockets library (SysLibSockets.lib)

The RTOS functions library (rtos.lib)

The SysLibEvent library (SysLibEvent.lib)

The SysLibCallback library (SysLibCallback.lib)

The SysLibDir library (SysLibDir.lib)

The SysLibPlcCtrl library (SysLibPlcCtrl.lib)

The SysLibStr library (SysLibStr.lib)

The FRAM library (FRAM_Lib.lib)

The RTC library (RTC_Lib.lib)

The MODEM library (MODEM_Lib.lib)

The TCPIP library (TCPIP_Lib.lib)

The MySQL library (MySQL_Lib.lib)

The MODBUS library (MODBUS_Lib.lib)

The RS485/Expansion library (RS485_Lib.lib)

Page 9: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

8

1.1 The SysLibCom library (SysLibCom.lib)

The implementation of the SysLibCom.lib on the CoDeSys Platform includes the standard CoDeSys SysLibCom functions. For help on these

functions is referenced to the standard SysLibCom documentation. Thereby some limitations should be taken into account which are described

below.

This chapter also describes the additional functions to the standard CoDeSys SysLibCom library.

Comments

The ports COM1 to COM3 are physical ports. Refer to the user manual of specific target for the availability and type of interface

(RS485/RS232).

RS232 port can also be used as programming port. Set COMx=PROG (where x is RS232 port number) in the CHIP.INI file to enable

this option. The default for COMx option is USER enabling this port for user application by IEC libraries.

For COM1 to COM3 must be used RS485/Serial library instead or specific protocol library (for example MODBUS RTU).

Limitations

The following limitations have to be taken into account:

- The DTR/DSR/DCD Signals are not supported.

- The option 1 for stop bits (1.5 stop bits) is not supported.

- The total size of bits (data + parity + stop) may not exceed 10 bits.

- It is strongly recomendend to check the return values of the functions.

Here is a list of all the functions this library offers:

SysComFlush

SysComPurge

SysComRxNum

SysComReadLine

Page 10: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

9

1.1.1 SysComFlush

FUNCTION SysComFlush : BOOL

VAR_INPUT

dwHandle : DWORD;

END_VAR

Wait until all data from the output buffer has been sent.

Return Value

TRUE : success

FALSE : error

Input Parameters

dwHandle

Port handle

Page 11: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

10

1.1.2 SysComPurge

FUNCTION SysComPurge : BOOL

VAR_INPUT

dwHandle : DWORD;

bPurgeIn : BOOL;

bPurgeOut : BOOL;

END_VAR

Discard the contents of the serial Transmit and/or Receive buffer(s).

Return Value

TRUE : success

FALSE : error

Input Parameters

dwHandle

Port handle

bPurgeIn

Set to TRUE to purge the Input buffer

bPurgeOut

Set to TRUE to purge the Output buffer

Page 12: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

11

1.1.3 SysComReadLine

FUNCTION SysComReadLine : DWORD

VAR_INPUT

dwHandle : DWORD;

dwBufferAddress : DWORD;

dwMaxBytesToRead : DWORD;

dwTimeout : DWORD;

END_VAR

Read a line from the Com port until Linefeed or max chars.

Return Value

Returns the number of characters read (including linefeed)

0 : Error or no chars read

Input Parameters

dwHandle

Port handle, acquired by SysComOpen

dwBufferAddress

Address of the buffer to store the read chars

dwMaxBytesToRead

Maximum number of characters to read

dwTimeout

Time (ms) after that the function returns at the latest

Page 13: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

12

1.1.4 SysComRxNum

FUNCTION SysComRxNum : INT

VAR_INPUT

dwHandle : DWORD;

END_VAR

Return the number of available characters in the input buffer.

Return Value

The number of characters available

Input Parameters

dwHandle

Port handle

Page 14: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

13

1.2 The SysLibSockets library (SysLibSockets.lib)

This chapter describes all functions which are available.

Important: Some functions of the socket interface are blocking. This means that the task which is calling the function pauses until the function

can return an expected result (e.g. SysSockRecv waits for some TCP data, SysSockRecvFrom waits for receiving an UDP datagram,

SysSockAccept waits for an incoming connection, ...).

This library offers the following functions and data types:

INADDR

SOCK_IP_MREQ

SOCKADDRESS

SOCKET_FD_SET

SOCKET_LINGER

SOCKET_TIMEVAL

SysSockAccept

SysSockBind

SysSockClose

SysSockConnect

SysSockCreate

SysSockGetHostByName

SysSockGetHostName

SysSockGetLastErrorSync

SysSockGetOption

SysSockHtonl

SysSockHtons

SysSockInetAddr

SysSockInetNtoa

SysSockIoctl

SysSockListen

SysSockNtohl

SysSockNtohs

SysSockRecv

SysSockRecvFrom

SysSockSelect

SysSockSend

SysSockSendTo

SysSockSetIPAddress

SysSockSetOption

SysSockShutdown

Page 15: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

14

1.2.1 TYPE INADDR

TYPE INADDR

TYPE INADDR : STRUCT S_addr : DWORD; END_STRUCT END_TYPE

Contains an IP address.

Member

S_addr

IP address in DWORD format. To compute the IP address in DWORD format see function SysSockInetAddr.

Page 16: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

15

1.2.2 TYPE SOCK_IP_MREQ

TYPE SOCK_IP_MREQ

TYPE SOCK_IP_MREQ : STRUCT imr_multiaddr : INADDR; imr_interface : INADDR; END_STRUCT END_TYPE

Multicast request data type.

Member

imr_multiaddr

Multicast group to join

imr_interface

Interface to join on

Page 17: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

16

1.2.3 TYPE SOCKADDRESS

TYPE SOCKADDRESS

TYPE SOCKADDRESS : STRUCT sin_family : INT; sin_port : UINT; sin_addr : UDINT; sin_zero : ARRAY [0..7] OF SINT; END_STRUCT END_TYPE

Contains an IP address and a port number.

Member

sin_family

Address family (must by equal to SOCKET_AF_INET)

sin_port

Port in network order. To compute the port in network order use function SysSockHtons.

sin_addr

IP address in DWORD format. To compute the IP address in DWORD format see function SysSockInetAddr.

sin_zero

Not used

Page 18: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

17

1.2.4 TYPE SOCKET_FD_SET

TYPE SOCKET_FD_SET

TYPE SOCKET_FD_SET : STRUCT fd_count : UDINT; fd_array : ARRAY [0..63] OF DINT; END_STRUCT END_TYPE

Contains a socket descriptor set.

Member

fd_count

Number of sockets in this set

fd_array

Socket descriptor list

Page 19: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

18

1.2.5 TYPE SOCKET_LINGER

TYPE SOCKET_LINGER

TYPE SOCKET_LINGER : STRUCT l_onoff : WORD; l_linger : WORD; END_STRUCT END_TYPE

Linger data type of TCP socket

Member

l_onoff

On/Off of linger

l_linger

Value of linger

Page 20: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

19

1.2.6 TYPE SOCKET_TIMEVAL

TYPE SOCKET_TIMEVAL

TYPE SOCKET_TIMEVAL : STRUCT tv_sec : DINT; tv_usec : DINT; END_STRUCT END_TYPE

Contains a Time specification.

Member

tv_sec

Time in Seconds

tv_usec

Time in Microseconds

Page 21: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

20

1.2.7 SysSockAccept

FUNCTION SysSockAccept : DINT

VAR_INPUT

diSocket : DINT;

pSockAddr : POINTER to SOCKADDR;

piSockAddrSize : POINTER to DINT;

END_VAR

Accepts an incoming connections.

NOTE: pSockAddr->sin_family must be set to SOCKET_AF_INET prior to call.

Return Value

-1 : error

>0 : success, new Socketdescriptor of accepted connection

Input Parameters

diSocket

Socket descriptor of the listening socket which waits for connections

pSockAddr

Pointer to a SOCKADDRESS struct where port and address of the incoming connection will be stored

piSockAddrSize

Pointer to a variable of type DINT. This variable has got assigned the length of the structure SockAddr (can be retrieved with the aid

of the SIZEOF operator).

Page 22: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

21

1.2.8 SysSockBind

FUNCTION SysSockBind : BOOL

VAR_INPUT

diSocket : DINT;

pSockAddr : POINTER to SOCKADDRESS;

diSockAddrSize : DINT;

END_VAR

Binds a socket to a specified local port or local address.

NOTE: pSockAddr->sin_family must be set to SOCKET_AF_INET prior to call.

Return Value

TRUE : success

FALSE : error

Input Parameters

diSocket

Socket descriptor

pSockAddr

Pointer to a SOCKADDRESS struct which specifies port and address

diSockAddrSize

Size of the SOCKADDRESS struct in bytes

Page 23: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

22

1.2.9 SysSockClose

FUNCTION SysSockClose : BOOL

VAR_INPUT

diSocket : DINT;

END_VAR

Closes a opened socket.

Return Value

TRUE : success

FALSE : error

Input Parameters

diSocket

Socket descriptor of the socket which should be closed

Page 24: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

23

1.2.10 SysSockConnect

FUNCTION SysSockConnect : BOOL

VAR_INPUT

diSocket : DINT;

pSockAddr : POINTER to SOCKADDR;

diSockAddrSize : DINT;

END_VAR

Establishs a connection to a TCP server.

NOTE: pSockAddr->sin_family must be set to SOCKET_AF_INET prior to call.

Return Value

TRUE : success

FALSE : error

Input Parameters

diSocket

Socket descriptor

pSockAddr

Pointer to a SOCKADDRESS struct which contains the address and the port of the TCP server

diSockAddrSize

Size of the SOCKADDRESS struct in bytes

Page 25: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

24

1.2.11 SysSockCreate

FUNCTION SysSockCreate : DINT

VAR_INPUT

diAddressFamiliy : DINT;

diType : DINT;

diProtocol : DINT;

END_VAR

Opens a new socket for UDP or TCP communication.

Return Value

-1 : error

>0 : success, new socket descriptor

Input Parameters

diAddressFamiliy

Address family, SOCKET_AF_INET supported only

diType

Socket type, SOCKET_STREAM for TCP, SOCKET_DGRAM for UDP

diProtocol

Protocol type, SOCKET_IPPROTO_IP supported only

Page 26: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

25

1.2.12 SysSockGetHostByName

FUNCTION SysSockGetHostByName : DWORD

VAR_INPUT

pHostName : POINTER to STRING;

END_VAR

Get the name of the host.

Return Value

SOCKET_INADDR_NONE : error, (16#FFFFFFFF)

else : success, valid hostaddress

Input Parameters

pHostName

Pointer to variable of type STRING containing the hostname

Page 27: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

26

1.2.13 SysSockGetHostName

FUNCTION SysSockGetHostName : BOOL

VAR_INPUT

pHostName : POINTER to STRING;

diNameLength : DINT;

END_VAR

Get the name of the host.

Return Value

TRUE : success

FALSE : error

Input Parameters

pHostName

Pointer to a variable of type STRING in which the hostname will be written (minimal 16 chars)

diNameLength

Length of the string in which the hostname will be written (minimal 16)

Page 28: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

27

1.2.14 SysSockGetLastErrorSync

FUNCTION SysSockGetLastErrorSync : DINT

VAR_INPUT

diSocket : DINT;

END_VAR

Return error code of last socket error.

Return Value

Error code of last occurred socket error

Input Parameters

diSocket

Socket descriptor

Comments

Socket error codes:

201 Operation not permitted

202 No such file or directory

203 No such process

204 Interrupted system call

205 Input/output error

206 Device not configured

209 Bad file descriptor

210 No child processes

211 Cannot allocate memory

213 Permission denied

214 Bad address

217 File exists

219 Operation not supported by device

220 Not a directory

221 Is a directory

222 Invalid argument

224 No resource available

235 Operation would block

236 Operation now in progress

237 Operation already in progress

238 Socket operation on non-socket

239 Destination address required

240 Message too long

241 Protocol wrong type for socket

242 Protocol not available

243 Protocol not supported

244 Socket type not supported

245 Operation not supported

246 Protocol family not supported

247 Address family not supported by protocol family

248 Address already in use

249 Can't assign requested address

250 Network is down

251 Network is unreachable

252 Network dropped connection on reset

253 Software caused connection abort

254 Connection reset by peer

255 No buffer space available

256 Socket is already connected

257 Socket is not connected

258 Can't send/receive after socket shutdown. There is no more data to be received.

259 Too many references: can't splice

260 Operation timed out

Page 29: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

28

261 Connection refused

264 Host is down

265 No route to host

Page 30: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

29

1.2.15 SysSockGetOption

FUNCTION SysSockGetOption : BOOL

VAR_INPUT

diSocket : DINT;

diLevel : DINT;

diOption : DINT;

pOptionValue : POINTER;

piOptionValueLength : POINTER to DINT;

END_VAR

Reads the setting of specified socket and the specified option.

Return Value

TRUE : success

FALSE : error

Input Parameters

diSocket

Socket descriptor

diLevel

Protocol level

diOption

Option which should be read (see below)

pOptionValue

Pointer to a variable to store the option value (see below)

piOptionValueLength

Pointer to an DINT which tells the size of the variable to which pOptionValue points (see below)

Comments

Supported Options:

diLevel = SOCKET_SOL

o diOption = SOCKET_SO_REUSEADDR Value type: INT Value: 1 = enable reuse address, 0 = disable reuse address, default: 1

o diOption = SOCKET_SO_KEEPALIVE Value type: INT Value: keepalive interval in seconds, min: 10, max: 32767, default: 7200

o diOption = SOCKET_SO_SNDBUF Value type: DINT Value: Sendbuffer size for that socket in bytes, default: 4096 for TCP, 2048 for UDP (max size 8192 bytes).

o diOption = SOCKET_SO_RCVBUF Value type: DINT Value: Receivebuffer size for that socket in bytes, default:4096 for TCP, 2048 for UDP (max size 8192 bytes).

o diOption = SOCKET_SO_ERROR Value type: DUINT Value: Last error occurred on that socket.

diLevel = SOCKET_IPPROTO_TCP

o diOption = SOCKET_TCP_NODELAY Value type: INT Value: -1 = disable nagle algorithm, 0 = nagle algorithm is enabled, default: 0

Page 31: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

30

1.2.16 SysSockHtonl

FUNCTION SysSockHtonl : DWORD

VAR_INPUT

dwHost : DWORD;

END_VAR

Converts a DWORD from host byte order to network byte order (in context with Big Endian and Little Endian format).

Return Value

Converted DWORD value

Input Parameters

dwHost

Value to convert

Page 32: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

31

1.2.17 SysSockHtons

FUNCTION SysSockHtons : WORD

VAR_INPUT

wHost : WORD;

END_VAR

Converts a WORD from host byte order to network byte order (in context with Big Endian and Little Endian format).

Return Value

Converted WORD value

Input Parameters

wHost

Value to convert

Page 33: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

32

1.2.18 SysSockInetAddr

FUNCTION SysSockInetAddr : DWORD

VAR_INPUT

stIPAddr : STRING;

END_VAR

Converts an IP address from String into a DWORD for the INADDR struct.

Return Value

IP Address as DWORD. This return value will be used to specify the field S_addr of the INADDR struct.

Input Parameters

stIPAddr

IP address string (e.g. '192.168.100.1')

Page 34: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

33

1.2.19 SysSockInetNtoa

FUNCTION SysSockInetNtoa : BOOL

VAR_INPUT

pInAddr : POINTER to INADDR;

pIPAddr : POINTER to STRING;

diIPAddrSize : DINT;

END_VAR

Converts a IP address from INADDR format to String.

Return Value

TRUE : success

FALSE : error

Input Parameters

pInAddr

Pointer to structure INADDR which contains the IP address

pIPAddr

Pointer to String where the IP address in String format should be stored

diIPAddrSize

Size of the pIPAddr String

Page 35: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

34

1.2.20 SysSockIoctl

FUNCTION SysSockIoctl : DINT

VAR_INPUT

diSocket : DINT;

diCommand : DINT;

piParameter : POINTER;

END_VAR

Manipulates a socket.

Return Value

Depends on the diCommand parameter

Input Parameters

diSocket

Socket descriptor

diCommand

Command which specifies what should be done with the socket (see below)

piParameter

Pointer to Parameter, depending on the command (see below)

Comments

Possible commands:

SOCKET_FIONREAD - Returns the number of bytes waiting in the receive buffer. Returns 0 on success and -1 on error.

o Parameter: Pointer to DINT where the number of bytes will be stored

SOCKET_FIONBIO - Switches the socket between nonblocking and blocking mode. (*) Returns 0 on success and -1 on error.

o Parameter: Pointer to DINT which specifies if the socket should be switched in blocking or in nonblocking mode (0 -> Blocking mode, <>0 -> Nonblocking mode)

(*) By default every socket is in blocking mode so all functions are blocking. This means a socket function does not return until an

expected result can be returned. So the calling task pauses until the function returns. E.g. the SysSockAccept function does not return

until a client establishes a connection to the socket. Or the SysSockRecv function does not return until some data is available in the

receive buffer of the socket. Using the SOCKET_FIONBIO command, a socket (and so its functions) can be switched into the non

blocking mode. Using the return values of the socket functions you can decide if the function call was successful or if an error has

occured. If an error has occured you can use the function SysSockGetOption to read the error code. With the error code you can see

if a real error has occured or the function would block. If the function would block, you have to call that function again until it would not

block anymore.

Example in ST:

IF NOT ConnectionIsEstablished THEN bRet := SysSockConnect(sd, ADR(addr), sizeof(addr)); IF bRet=FALSE THEN diError := 0; dwErrorSize := sizeof(diError); bRet := SysSockGetOption(sd, SOCKET_SOL, SOCKET_ERROR, ADR(diError), ADR(diErrorSize)); IF (bRet=FALSE) OR (diError<>235) THEN bConnectionError := TRUE; END_IF ELSE

Page 36: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

35

ConnectionIsEstablished := TRUE; END_IF END_IF

Page 37: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

36

1.2.21 SysSockListen

FUNCTION SysSockListen : BOOL

VAR_INPUT

diSocket : DINT;

diMaxConnections : DINT;

END_VAR

Switches a sockets into the listen mode so it can accept connection requests.

Return Value

TRUE : success

FALSE : error

Input Parameters

diSocket

Socket descriptor

diMaxConnections

Max. number of simultanious connections

Page 38: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

37

1.2.22 SysSockNtohl

FUNCTION SysSockNtohl : DWORD

VAR_INPUT

dwNet : DWORD;

END_VAR

Converts a DWORD from network byte order to host byte order (in context with Big Endian and Little Endian format).

Return Value

Converted DWORD value

Input Parameters

dwNet

Value to convert

Page 39: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

38

1.2.23 SysSockNtohs

FUNCTION SysSockNtohs : WORD

VAR_INPUT

wNet : WORD;

END_VAR

Converts a WORD from network byte order to host byte order (in context with Big Endian and Little Endian format).

Return Value

Converted WORD value

Input Parameters

wNet

Value to convert

Page 40: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

39

1.2.24 SysSockRecv

FUNCTION SysSockRecv : DINT

VAR_INPUT

diSocket : DINT;

pbyBuffer : POINTER to BYTE;

diBufferSize : DINT;

diFlags : DINT;

END_VAR

Receives some data from an established TCP connection.

Return Value

Number of the received bytes

Input Parameters

diSocket

Socket descriptor of the established connection

pbyBuffer

Pointer to buffer of type BYTE where the received data should be stored

diBufferSize

Size of the buffer

diFlags

Flags (must be equal to null)

Page 41: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

40

1.2.25 SysSockRecvFrom

FUNCTION SysSockRecvFrom : DINT

VAR_INPUT

diSocket : DINT;

pbyBuffer : POINTER to BYTE;

diBufferSize : DINT;

diFlags : DINT;

pSockAddr : POINTER to SOCKADRR;

diSockAddrSize : DINT;

END_VAR

Receives a UDP datagram from another UDP station.

NOTE: pSockAddr->sin_family must be set to SOCKET_AF_INET prior to call.

Return Value

Number of the received bytes

Input Parameters

diSocket

Socket descriptor

pbyBuffer

Pointer to buffer of type BYTE where the datagram should be stored

diBufferSize

Size of the buffer

diFlags

Flags (must be equal to null)

pSockAddr

Pointer to a SOCKADDRESS struct where the source address and port (of the sender) should be stored

diSockAddrSize

Size of the SOCKADDRESS struct in bytes

Page 42: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

41

1.2.26 SysSockSelect

FUNCTION SysSockSelect : DINT

VAR_INPUT

diWidth : DINT;

fdRead : POINTER to SOCKET_FD_SET;

fdWrite : POINTER to SOCKET_FD_SET;

fdExcept : POINTER to SOCKET_FD_SET;

ptvTimeout : POINTER to SOCKET_TIMEVAL;

END_VAR

Determine status of one or more sockets.

Return Value

0 : timeout

>0 : number of sockets for which a specified event has occurred

Input Parameters

diWidth

Number of elements of the fd_array field in the structure SOCKET_FD_SET

fdRead

Pointer to structure, defining the socket set from which the read status should be checked

fdWrite

Pointer to structure, defining the socket set from which the write status should be checked

fdExcept

Pointer to structure, defining the socket set from which the Error status should be checked

ptvTimeout

Pointer to structure containing the maximum time to wait for a result

Comments

For any of the pointers to SOCKET_FD_SET, a NULL Pointer is allowed when this group is not relevant.

Page 43: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

42

1.2.27 SysSockSend

FUNCTION SysSockSend : DINT

VAR_INPUT

diSocket : DINT;

pbyBuffer : POINTER to BYTE;

diBufferSize : DINT;

diFlags : DINT;

END_VAR

Sends some data to an established TCP connection.

Return Value

-1 : error

else : success, number of bytes sent

Input Parameters

diSocket

Socket descriptor of the established connection

pbyBuffer

Pointer to buffer of type BYTE which should be sent

diBufferSize

Size of the data which should be sent in bytes

diFlags

Flags (must be equal to null)

Page 44: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

43

1.2.28 SysSockSendTo

FUNCTION SysSockSendTo : DINT

VAR_INPUT

diSocket : DINT;

pbyBuffer : POINTER to BYTE;

diBufferSize : DINT;

diFlags : DINT;

pSockAddr : POINTER to SOCKADDR;

diSockAddrSize : DINT;

END_VAR

Sends a UDP datagram to another UDP station.

NOTE: pSockAddr->sin_family must be set to SOCKET_AF_INET prior to call.

Return Value

Number of transfered bytes

Input Parameters

diSocket

Socket descriptor

pbyBuffer

Pointer to buffer of type BYTE which should be sent

diBufferSize

Size of the data to send in bytes

diFlags

Flags (must be equal to null)

pSockAddr

Points to a SOCKADDRESS struct which contains the destination address and port

diSockAddrSize

Size of the SOCKADDRESS struct in bytes

Page 45: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

44

1.2.29 SysSockSetIPAddress

This function is not implemented in this version of the Release.

NOTE: A call to this function returns always zero.

Page 46: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

45

1.2.30 SysSockSetOption

FUNCTION SysSockSetOption : BOOL

VAR_INPUT

diSocket : DINT;

diLevel : DINT;

diOption : DINT;

pOptionValue : POINTER;

dwOptionValueLength : DWORD;

END_VAR

Controls option settings for specified Socket.

Return Value

TRUE : success

FALSE : error

Input Parameters

diSocket

Socket descriptor

diLevel

Protocol level

diOption

Option which should be set

pOptionValue

Pointer to a variable containing the option value

dwOptionValueLength

Length (in Bytes) of the option value

Comments

For the supported options see function SysSockGetOption.

Page 47: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

46

1.2.31 SysSockShutdown

FUNCTION SysSockShutdown : BOOL

VAR_INPUT

diSocket : DINT;

diHow : DINT;

END_VAR

Closes a connection.

Return Value

TRUE : success

FALSE : error

Input Parameters

diSocket

Socket descriptor

diHow

Must be equal to null

Page 48: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

47

1.3 The RTOS functions library (rtos.lib)

The RTOS library offers various functions of the underlying Real Time Operating System to the PLC programmer.

These functions include IP configuration, device names and versions, and message exchange functions.

Some of the functions are only useful on controllers supporting parallel execution of DOS EXE programs, others can also be used in pure PLC

applications.

Here is a list of all the functions and data type this library offers:

TYPE MSG_EX

RtosCreateMsg

RtosDeleteMsg

RtosDhcpUse

RtosFindMsg

RtosGetBootstrapVersion

RtosGetDevicenames

RtosGetDhcpStat

RtosGetIniEntry

RtosGetIniEntryEx

RtosGetLinkstate

RtosGetMacAddress

RtosGetMsg

RtosGetRebootReason

RtosGetTick_us

RtosGetVersion

RtosGetVersionString

RtosIpconfig

RtosReboot

RtosSendMsg

RtosServers

RtosSetIniEntry

RtosSetIniEntryEx

Page 49: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

48

1.3.1 TYPE MSG_EX

TYPE MSG_EX

TYPE MSG_EX : STRUCT msgID : UINT := 0; name0 : USINT := 77; (* 'M' *) name1 : USINT := 83; (* 'S' *) name2 : USINT := 71; (* 'G' *) name3 : USINT := 88; (* 'X' *) mb0 : INT := 2; mb1 : INT := 2; mb2 : INT := 2; mb3 : INT := 2; END_STRUCT END_TYPE

This structure contains information about a message exchange. It is used with the message exchange functions from the RTOS library, like

RtosCreateMsg

RtosDeleteMsg

RtosSendMsg

RtosGetMsg

RtosFindMsg

Member

msgID

filled by RtosCreateMsg function

name0

'M'

name1

'S'

name2

'G'

name3

'X'

mb0

number of envelopes, priority 0 (high)

mb1

number of envelopes, priority 1

mb2

number of envelopes, priority 2

mb3

number of envelopes, priority 3 (low)

Page 50: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

49

1.3.2 RtosCreateMsg

FUNCTION RtosCreateMsg : INT

VAR_INPUT

pMsgEx : POINTER to MSG_EX;

END_VAR

This function creates a message exchange. You must call this function before the message exchange mechanism can be used. RtosCreateMsg

fills in the msgID member of the MSG_EX structure. This ID number of the message exchange will be used by other functions to access the

message exchange.

Additionally, you can provide a unique 4 character tag to identify the message exchange when using the RtosFindMsg function.

Return Value

Returns 0 in case of success, otherwise the error code from the operating system

Input Parameters

pMsgEx

Pointer to a MSG_EX structure

Related Topics

RtosDeleteMsg

RtosFindMsg

Page 51: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

50

1.3.3 RtosDeleteMsg

FUNCTION RtosDeleteMsg : INT

VAR_INPUT

msgID : UINT;

END_VAR

This function deletes a message exchange that is no longer used.

Return Value

Returns 0 in case of success, otherwise an error code

Input Parameters

msgID

Number of the message exchange, as returned by RtosCreateMsg in the structure MSG_EX

Related Topics

RtosCreateMsg

Page 52: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

51

1.3.4 RtosDhcpUse

FUNCTION RtosDhcpUse : BYTE

VAR_INPUT

onOffRead : BYTE;

END_VAR

Switches DHCP usage on/off or determines wether DHCP usage is on/off.

Return Value

0 = DHCP is off, 1 = DHCP is on

Input Parameters

onOffRead

0 = set DHCP off, 1 = set DHCP on, 2 = read DHCP usage

Related Topics

RtosIpconfig

Page 53: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

52

1.3.5 RtosFindMsg

FUNCTION RtosFindMsg : INT

VAR_INPUT

pID : POINTER to UINT;

pName : POINTER to STRING;

END_VAR

Finds the ID of a message exchange by the 4 character name.

Return Value

Returns 0 on success, otherwise error code

Input Parameters

pID

Pointer to a UINT into which the ID of the message exchange will be stored

pName

Pointer to 4 bytes containing the name of the message exchange, as defined in the MSG_EX structure before calling RtosCreateMsg

Related Topics

RtosCreateMsg

Page 54: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

53

1.3.6 RtosGetBootstrapVersion

FUNCTION RtosGetBootstrapVersion : WORD

VAR_INPUT

dummy : BYTE;

END_VAR

Returns the version of the processor's bootstrap loader.

Return Value

The bootstrap loader version is returned in one WORD, where the high byte is the more significant digit, the low byte is the less

significant digit

Input Parameters

dummy

Not used

Related Topics

RtosGetVersion

RtosGetVersionString

Page 55: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

54

1.3.7 RtosGetDevicenames

FUNCTION RtosGetDevicenames : BYTE

VAR_INPUT

ppChipName : POINTER to POINTER to STRING;

ppIniName : POINTER to POINTER to STRING;

ppProductName : POINTER to POINTER to STRING;

END_VAR

Returns pointers to the device names of the controller.

Input Parameters

ppChipName

Output paramter: pointer to a string pointer which will receive a pointer to the fixed device name stored in the processor's flash

memory

ppIniName

Output paramter: pointer to a string pointer which will receive a pointer to the device name configured in CHIP.INI

ppProductName

Output paramter: pointer to a string pointer which will receive a pointer to the fixed product device name stored in the flash memory

Comments

Example for using RtosGetDeviceNames in Structured Text language:

VAR p1 : POINTER TO STRING; p2 : POINTER TO STRING; p3 : POINTER TO STRING; s1 : STRING; s2 : STRING; s3 : STRING; END_VAR RtosGetDevicenames(ADR(p1), ADR(p2), ADR(p3)); s1 := p1^; s2 := p2^; s3 := p3^;

Page 56: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

55

1.3.8 RtosGetDhcpStat

FUNCTION RtosGetDhcpStat : WORD

VAR_INPUT

dummy : BYTE;

END_VAR

Returns the status of the DHCP client (if DHCP is on).

Return Value

0 = DHCP configuration in progress

1 = successfully configured via DHCP

2 = DHCP failed

Input Parameters

dummy

Not used

Related Topics

RtosDhcpUse

Page 57: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

56

1.3.9 RtosGetIniEntry

FUNCTION RtosGetIniEntry : INT

VAR_INPUT

pSection : POINTER to STRING;

pItemname : POINTER to STRING;

pItemtext : POINTER to STRING;

len : UINT;

END_VAR

Reads an entry from the configuration file CHIP.INI on the controller's flash disk.

Return Value

0 = entry not found

-1 = CHIP.INI not found

otherwise number of characters read

Input Parameters

pSection

Pointer to string holding the section

pItemname

Pointer to string holding the name of the desired entry

pItemtext

Pointer to string in which the text of the desired entry will be copied (must be max_len+1 size)

len

Maximum lenghth of the target string at pItemtext, not including terminating null character

Comments

The functions RtosGetIniEntry and RtosSetIniEntry are not reentrant. Do not use these in different tasks or in combination with other

functions or commands which write to CHIP.INI, e.g. the DHCP or IP configuration functions.

Related Topics

RtosGetIniEntryEx

RtosSetIniEntry

RtosSetIniEntryEx

Page 58: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

57

1.3.10 RtosGetIniEntryEx

FUNCTION RtosGetIniEntryEx : INT

VAR_INPUT

pFilename : POINTER to STRING;

pSection : POINTER to STRING;

pItemname : POINTER to STRING;

pItemtext : POINTER to STRING;

len : UINT;

END_VAR

Reads an entry from a specified configuration file on the controller's flash disk.

Return Value

0 = entry not found

-1 = configuration file not found

otherwise number of characters read

Input Parameters

pFilename

Pointer to string holding the configuration file name (max. 80 characters)

pSection

Pointer to string holding the section

pItemname

Pointer to string holding the name of the desired entry

pItemtext

Pointer to string in which the text of the desired entry will be copied (must be max_len+1 size)

len

Maximum lenghth of the target string at pItemtext, not including terminating null character

Comments

The functions RtosGetIniEntryEx and RtosSetIniEntryEx are not reentrant. Do not use these in different tasks or in combination with

other functions or commands which write to the configuration file.

Related Topics

RtosGetIniEntry

RtosSetIniEntry

RtosSetIniEntryEx

Page 59: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

58

1.3.11 RtosGetLinkstate

FUNCTION RtosGetLinkstate : WORD

VAR_INPUT

dummy : BYTE;

END_VAR

Returns the link state of the controller's ethernet interface.

Return Value

bit 0: 1 = link ok, 0 = no link

bit 2: 1 = initialization of the ethernet device failed

Input Parameters

dummy

Not used

Related Topics

RtosGetMacAddress

Page 60: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

59

1.3.12 RtosGetMacAddress

FUNCTION RtosGetMacAddress : BYTE

VAR_INPUT

pBuf : POINTER to BYTE;

END_VAR

Returns the MAC address of the controller's ethernet interface.

Return Value

Returns always 0

Input Parameters

pBuf

Pointer to buffer for MAC address

Comments

The buffer must provide 6 bytes of space, e.g. be of the type ARRAY[0..5] OF BYTE

Page 61: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

60

1.3.13 RtosGetMsg

FUNCTION RtosGetMsg : INT

VAR_INPUT

msgID : UINT;

pMsg : DWORD;

END_VAR

Gets a message from a specified message exchange. Returns immediately if no message is available.

Return Value

Returns 0 on success, otherwise error code

Input Parameters

msgID

Number of the message exchange, as returned by RtosCreateMsg in the structure MSG_EX

pMsg

Pointer to a 12 byte buffer in which the message will be stored. The format of the data can be defined by the application program

Comments

This function returns immediately with code -28 if no message is available.

When more than one message is available at the message exchange, the oldest (FIFO order) message from the highest priority

message queue will be reported.

Related Topics

RtosSendMsg

Page 62: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

61

1.3.14 RtosGetRebootReason

FUNCTION RtosGetRebootReason : BYTE

VAR_INPUT

dummy : BYTE;

END_VAR

Returns the reason why the controller rebooted.

Return Value

Returns 0 if reboot reason is unknown, 3 if controller was rebooted by the watchdog, or 4 if the controller rebooted due to power

failure

Input Parameters

dummy

Not used

Comments

This function relies on the retain mechanism which is per default active to save data in case of power failure. So this function can only

be used if the controller supports retain variables.

Page 63: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

62

1.3.15 RtosGetTick_us

FUNCTION RtosGetTick_us : UDINT

VAR_INPUT

dummy : BYTE;

END_VAR

Reads current value of system time counter.

Return Value

Returns current value of system time counter (micro-seconds)

Input Parameters

dummy

Not used

Comments

This function reads current value of system time counter.

The value returned is unsigned 32-bits type. Note that this count rolls over to zero after each 2^32 microseconds of operation, which is

about 71.582 minutes.

Page 64: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

63

1.3.16 RtosGetVersion

FUNCTION RtosGetVersion : DWORD

VAR_INPUT

dummy : BYTE;

END_VAR

Returns the version of the operating system.

Return Value

High byte of the low word = more significant digit of the version number

Low byte of the low word = less significant digit of the version number

If the least significant bit of the high word is set, this is a beta version of the operating system

Input Parameters

dummy

Not used

Related Topics

RtosGetVersionString

RtosGetBootstrapVersion

Page 65: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

64

1.3.17 RtosGetVersionString

FUNCTION RtosGetVersionString : BYTE

VAR_INPUT

pBuf : POINTER to BYTE;

len : INT;

END_VAR

Returns the version of the operating system as a string.

Return Value

Returns always 0

Input Parameters

pBuf

Pointer to buffer where the version string will be stored

len

Size of buffer at pBuf, including space for terminating null character

Related Topics

RtosGetVersion

RtosGetBootstrapVersion

Page 66: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

65

1.3.18 RtosIpconfig

FUNCTION RtosIpconfig : BYTE

VAR_INPUT

set : BYTE;

pIpString : POINTER to STRING;

pSubString : POINTER to STRING;

pGatewayString : POINTER to STRING;

END_VAR

Sets or reads the controller's IP configuration.

Input Parameters

set

0 to read, 1 to set configuration

pIpString

Output parameter: pointer to a 16 byte memory area where the IP address is to be stored as a null terminated string when reading the

configuration or where the IP address will be read from when setting the configuration

pSubString

Output parameter: pointer to a 16 byte memory area where the subnet mask is to be stored as a null terminated string when reading

the configuration or where the subnet mask address will be read from when setting the configuration

pGatewayString

Output parameter: pointer to a 16 byte memory area where the gateway address is to be stored as a null terminated string when

reading the configuration or where the gateway address will be read from when setting the configuration

Comments

This function is useful if you want to set the IP configuration from the PLC application itself, e.g. using a graphical operator device.

However, in most cases the IP configuration will be edited using the PLC Configuration dialog in the programming system.

The strings are null terminated ASCII strings in dotted decimal notation (e.g. 192.168.10.3).

Any of the parameters can be set to 0 if the respective value is not to be set/read.

After setting the configuration, the ethernet interface will automatically be reconfigured.

Important: This function writes to the CHIP.INI file on the controller's flash disk and is not reentrant. Do not use this function in

different tasks or programs or in combination with other commands writing to the CHIP.INI.

Related Topics

RtosDhcpUse

Page 67: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

66

1.3.19 RtosReboot

FUNCTION RtosReboot : BYTE

VAR_INPUT

dummy : BYTE;

END_VAR

Reboots the controller.

Return Value

This function never returns

Input Parameters

dummy

Not used

Comments

While rebooting, the controller stops and does not respond any more. Do not reboot the controller if this could cause danger for

human beings, creatures, or material assets.

Page 68: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

67

1.3.20 RtosSendMsg

FUNCTION RtosSendMsg : INT

VAR_INPUT

msgID : UINT;

prio : INT;

pMsg : POINTER to BYTE;

END_VAR

Sends a message to the message exchange.

Return Value

Returns 0 on success, otherwise error code

Input Parameters

msgID

Number of the message exchange, as returned by RtosCreateMsg in the structure MSG_EX

prio

Priority, 0..3 where 0 is highest, 3 is lowest priority

pMsg

Pointer to 12 bytes of data which shall be sent to the message exchange. The format of the data can be defined by the application

program

Comments

Messages will be reported in message priority order, and from each priority queue in FIFO order.

Related Topics

RtosGetMsg

Page 69: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

68

1.3.21 RtosServers

FUNCTION RtosServers : BYTE

VAR_INPUT

server : BYTE;

stop : BYTE;

END_VAR

Starts/Stops the RTOS system servers.

Return Value

Returns always 0

Input Parameters

server

0 = FTP, 1 = telnet, 2 = web server

stop

0 = start server, 1 = stop server

Page 70: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

69

1.3.22 RtosSetIniEntry

FUNCTION RtosSetIniEntry : INT

VAR_INPUT

pSection : POINTER to STRING;

pItemname : POINTER to STRING;

pItemtext : POINTER to STRING;

END_VAR

Writes an entry to the configuration file CHIP.INI on the controller's flash disk.

Return Value

0 = ok

-1 = invalid string length

Input Parameters

pSection

Pointer to string holding the section (max. 40 characters)

pItemname

Pointer to string holding the name of the desired entry (max. 40 characters)

pItemtext

Pointer to string holding the text of the entry to be written (max. 128 characters)

Comments

The functions RtosGetIniEntry and RtosSetIniEntry are not reentrant. Do not use these in different tasks or in combination with other

functions or commands which write to CHIP.INI, e.g. the DHCP or IP configuration functions.

Related Topics

RtosGetIniEntry

RtosGetIniEntryEx

RtosSetIniEntryEx

Page 71: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

70

1.3.23 RtosSetIniEntryEx

FUNCTION RtosSetIniEntryEx : INT

VAR_INPUT

pFilename : POINTER to STRING;

pSection : POINTER to STRING;

pItemname : POINTER to STRING;

pItemtext : POINTER to STRING;

END_VAR

Writes an entry to a specified configuration file on the controller's flash disk.

Return Value

0 = ok

-1 = invalid string length

Input Parameters

pFilename

Pointer to string holding the configuration file name (max. 80 characters)

pSection

Pointer to string holding the section (max. 40 characters)

pItemname

Pointer to string holding the name of the desired entry (max. 40 characters)

pItemtext

Pointer to string holding the text of the entry to be written (max. 128 characters)

Comments

The functions RtosGetIniEntryEx and RtosSetIniEntryEx are not reentrant. Do not use these in different tasks or in combination with

other functions or commands which write to the configuration file.

Related Topics

RtosGetIniEntry

RtosGetIniEntryEx

RtosSetIniEntry

Page 72: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

71

1.4 The SysLibEvent library (SysLibEvent.lib)

Here is a list of all the functions this library offers:

SysEventCreate

SysEventDelete

SysEventSet

SysEventWait

Page 73: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

72

1.4.1 SysEventCreate

FUNCTION SysEventCreate : DWORD

VAR_INPUT

pName : POINTER to STRING;

END_VAR

Creates a new event with given name.

Return Value

16#FFFFFFFF : error

else : success, handle to new event which should be created

Input Parameters

pName

Pointer to STRING containing the name of the event

Page 74: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

73

1.4.2 SysEventDelete

FUNCTION SysEventDelete : BOOL

VAR_INPUT

dwHandle : DWORD;

END_VAR

Deletes an event.

Return Value

TRUE : success

FALSE : error

Input Parameters

dwHandle

Handle to event which should be deleted

Page 75: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

74

1.4.3 SysEventSet

FUNCTION SysEventSet : BOOL

VAR_INPUT

dwHandle : DWORD;

END_VAR

Sets an event.

Return Value

TRUE : success, event is set

FALSE : error

Input Parameters

dwHandle

Handle to event which should be set

Page 76: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

75

1.4.4 SysEventWait

FUNCTION SysEventWait : BOOL

VAR_INPUT

dwHandle : DWORD;

dwTimeout : DWORD;

END_VAR

Wait for an event to occur.

Return Value

TRUE : success, event occurred within timeout period

FALSE : error or timeout

Input Parameters

dwHandle

Handle to event which should be waited for

dwTimeout

Timeout (in ms) after which the function will return at the latest

Page 77: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

76

1.5 The SysLibCallback library (SysLibCallback.lib)

The implementation of the SysLibCallback.lib on the CoDeSys Platform is identical with the standard CoDeSys SysLibCallback documentation.

So we request you to use that documentation.

Important Note: For a stable operation of the RTS, it is very important that the callback function is defined exactly as described in the 3S online

help. Such a function may not have any local variables! If local variables are needed, an empty Wrapper function must be used.

Page 78: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

77

1.6 The SysLibDir library (SysLibDir.lib)

The implementation of the SysLibDir.lib on the CoDeSys Platform is identical with the standard CoDeSys SysLibDir documentation. So we

request you to use that documentation.

Comments

The File DateTime field of the DIRECTORY_INFO stucture is not supported yet. Use the function SysFileGetTime to get this

information.

Page 79: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

78

1.7 The SysLibPlcCtrl library (SysLibPlcCtrl.lib)

The implementation of the SysLibPlcCtrl.lib on the CoDeSys Platform is identical with the standard CoDeSys SysLibPlcCtrl documentation. So

we request you to use that documentation.

Comments

The functions SysShutdownPlc, SysEnableScheduling, and GetPlcLoad are not supported in this Release.

Page 80: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

79

1.8 The SysLibStr library (SysLibStr.lib)

The implementation of the SysLibStr.lib on the CoDeSys Platform is identical with the standard CoDeSys SysLibStr documentation. So we

request you to use that documentation.

Comments

The maximum length of strings is limited to 64Kb in this Release.

Page 81: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

80

1.9 The FRAM library (FRAM_Lib.lib)

This library offers the functions for the management of the FRAM memory.

The FRAM memory (Ferroelectric RAM) is a memory that has all the characteristics of the ideal memory. It is in fact retentive to the default of

power supply without necessity of batteries, high-speed in writing (in the order of the microseconds against the milliseconds of the

EEprom/Flash memory), rewritetable around 10e16 times (against 10e6/10e5 times of the EEprom/Flash) and retainment of data for 45 years.

The management of FRAM device is faculty of the programmer. Nevertheless, in the case of IEC retain memory saving into FRAM (option

RETAIN=FRAM in the CHIP.INI file) this is not possible because FRAM is directly handled by the operating system.

This library offers the following functions:

FRAM_Read

FRAM_Write

Page 82: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

81

1.9.1 FRAM_Read

FUNCTION FRAM_Read : BOOL

VAR_INPUT

Address : UINT;

NumBytes : UINT;

Buffer : DWORD;

END_VAR

Reads a FRAM memory area.

Return Value

TRUE : success

FALSE : error

Input Parameters

Address

Start address of FRAM memory area (0-8191)

BumBytes

Number of bytes to read

Buffer

Pointer to buffer where to store readed bytes (use ADR() function)

Comments

This function reads an array of bytes from external FRAM device.

External FRAM device has a dimension of 8Kbytes (8192 bytes) and is addressed from 0 to 8191. For the pointer value of a IEC

variable to store the readed bytes, ADR() function can be used.

Related Topics

FRAM_Write

Page 83: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

82

1.9.2 FRAM_Write

FUNCTION FRAM_Write : BOOL

VAR_INPUT

Address : UINT;

NumBytes : UINT;

Buffer : DWORD;

END_VAR

Writes a FRAM memory area.

Return Value

TRUE : success

FALSE : error

Input Parameters

Address

Start address of FRAM memory area (0-8192)

BumBytes

Number of bytes to read

Buffer

Pointer to buffer where to store readed bytes (use ADR() function)

Comments

This function writes an array of bytes into external FRAM device.

External FRAM device has a dimension of 8Kbytes (8192 bytes) and is addressed from 0 to 8191. For the pointer value of a IEC

variable to get the bytes to write, ADR() function can be used.

Related Topics

FRAM_Read

Page 84: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

83

1.10 The RTC library (RTC_Lib.lib)

This library offers the functions for the management of the Real Time Clock.

Here is a list of all the functions this library offers:

DateTime_Read

RTC_Read

RTC_Write

Page 85: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

84

1.10.1 DateTime_Read

FUNCTION DateTime_Read : DT

VAR_INPUT

Enable : BOOL;

END_VAR

Reads current date and time from Real Time Clock.

Return Value

Returns current date and time into DT type variable

Input Parameters

Enable

Enable the function execution

Comments

This function reads date and time from external Real Time Clock device.

The value returned is of DT (DATE AND TIME) standard type.

You advises to periodically execute the function, for example at intervals of 1s, to refresh the value of date and time into a global

variable.

If the function is not enabled returns the reference date and time value (DT#1970-01-01-00:00).

Page 86: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

85

1.10.2 RTC_Read

FUNCTION RTC_Read : SystemTimeDate

VAR_INPUT

Enable : BOOL;

END_VAR

Reads current date and time from Real Time Clock.

Return Value

Returns current date and time into SystemTimeDate type variable

Input Parameters

Enable

Enable the function execution

Comments

This function reads date and time from external Real Time Clock device.

The value returned is of SystemTimeDate type defined into SysLibTime.lib standard library.

You advises to periodically execute the function, for example at intervals of 1s, to refresh the value of date and time into a global

variable.

Related Topics

RTC_Write

Page 87: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

86

1.10.3 RTC_Write

FUNCTION RTC_Write : BOOL

VAR_INPUT

Enable : BOOL;

Setup : SystemTimeDate;

END_VAR

Updates current date and time into Real Time Clock.

Return Value

TRUE : Success

FALSE : Error

Input Parameters

Enable

Enable the function execution

Setup

Value of SystemTimeDate type to be forced into Real Time Clock

Comments

This function updates date and time into external Real Time Clock device.

The value to be forced is of SystemTimeDate type defined into SysLibTime.lib standard library.

Related Topics

RTC_Read

Page 88: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

87

1.11 The MODEM library (MODEM_Lib.lib)

This library offers the functions for the management of the MODEM .

Refer to the documentation of the specific Target to check the availability and type of modem.

Here is a list of all the functions this library offers:

TYPE DYNDNS_STATUS

TYPE MODEM_CHAR_SET

TYPE MODEM_COMMAND

TYPE MODEM_DATA_SERVICE

TYPE MODEM_STATUS

DynDNS_Client

GM01_PPP

GM01_PPP_SMS_Call

GM01_SMS

NOTE: GM01_PPP and GM01_SMS function blocks perform the functions limited to their type of service and cannot be used simultaneously.

For a complete management of all the capabilities of the modem, it's recommend the use of the GM01_PPP_SMS_Call function block which

also includes several other features.

Page 89: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

88

1.11.1 DYNDNS_STATUS

TYPE DYNDNS_STATUS

TYPE DYNDNS_STATUS : ( DYNDNS_STANDBY := 0, DYNDNS_UPDATING := 1, DYNDNS_UPDATED := 2, DYNDNS_FAILED := 3, DYNDNS_RETRY_WAIT := 4 ) := DYNDNS_STANDBY; END_TYPE

This type enumerates the current status of Dynamic DNS Client.

Member

DYNDNS_STANDBY := 0

Service is waiting for activation

DYNDNS_UPDATING := 1

Updating request in progress

DYNDNS_UPDATED := 2

IP address is updated on the server

DYNDNS_FAILED := 3

Update on the server failed

DYNDNS_RETRY_WAIT := 4

Waiting before retry

Page 90: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

89

1.11.2 MODEM_CHAR_SET

TYPE MODEM_CHAR_SET

TYPE MODEM_CHAR_SET : ( MODEM_CHAR_SET_ASCII := 0, MODEM_CHAR_SET_GSM := 1, MODEM_CHAR_SET_UCS2 := 2, MODEM_CHAR_SET_UTF8 := 3, MODEM_CHAR_SET_8859_1 := 4 ) := MODEM_CHAR_SET_ASCII; END_TYPE

This type enumerates the current character set for SMS.

Member

MODEM_CHAR_SET_ASCII := 0

ASCII characters (0x00-0x7F)

MODEM_CHAR_SET_GSM := 1

GSM default alphabet (GSM 03.38 subclause 6.2.1)

MODEM_CHAR_SET_UCS2 := 2

Unicode (ISO/IEC 10646[32])

MODEM_CHAR_SET_UTF8 := 3

Unicode 8 bit (ISO 10646 transformation format)

MODEM_CHAR_SET_8859_1 := 4

Latin 1 (ISO 8859-1)

Page 91: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

90

1.11.3 MODEM_COMMAND

TYPE MODEM_COMMAND

TYPE MODEM_COMMAND : ( MODEM_NO_COMMAND := 0, MODEM_SIGNAL_READ := 1, MODEM_DEL_ALL_SMS := 20 ) := MODEM_NO_COMMAND; END_TYPE

This type enumerates the codes of auxiliary commands for the modem.

Member

MODEM_NO_COMMAND := 0

No command is requested

MODEM_SIGNAL_READ := 1

Update the reading of field strength of the radio network

MODEM_DEL_ALL_SMS := 20

Delete all SMS message stored into SIM card (use with caution!) *)

Page 92: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

91

1.11.4 MODEM_DATA_SERVICE

TYPE MODEM_DATA_SERVICE

TYPE MODEM_DATA_SERVICE : ( MODEM_DATA_NO := 0, MODEM_DATA_GPRS := 1 MODEM_DATA_EDGE := 2 MODEM_DATA_UMTS := 3 MODEM_DATA_UMTS_HSDPA := 4 MODEM_DATA_UMTS_HSUPA := 5 MODEM_DATA_UMTS_HSDPA_HSUPA := 6 ) := MODEM_DATA_NO; END_TYPE

This type enumerates the codes of packet data service established.

Member

MODEM_DATA_NO := 0

No data service available

MODEM_DATA_GPRS := 1

GPRS data service available

MODEM_DATA_EDGE := 2

EDGE data service available

MODEM_DATA_UMTS := 3

UMTS data service available

MODEM_DATA_UMTS_HSDPA := 4

UMTS/HSDPA data service available

MODEM_DATA_UMTS_HSUPA := 5

UMTS/HSUPA data service available

MODEM_DATA_UMTS_HSDPA_HSUPA := 6

UMTS/HSDPA-HSUPA data service available

Page 93: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

92

1.11.5 MODEM_STATUS

TYPE MODEM_STATUS

TYPE MODEM_STATUS : ( MODEM_STANDBY := 0, MODEM_INIT := 1, NET_REGISTRATION := 2, PPP_CONNECTING := 3, MODEM_CONNECTED := 4, PPP_LINK_LOST := 5, MODEM_DCD_LOST := 6, MODEM_DEINIT := 7, MODEM_RETRY_WAIT := 8, DYNDNS_REQUEST := 10, DYNDNS_OK := 11, DYNDNS_FAIL := 12, SMS_SENDING := 20, SMS_SENDED := 21, SMS_SEND_ERROR := 22, SMS_GETTING := 23, SMS_RECEIVED := 24, SMS_NOT_RECEIVED := 25, SMS_SEND_CONFIRMED := 26, SMS_SEND_CONFIRMING := 27, SMS_SEND_CONFIRM_ERR := 28, CALL_SENDING := 30, CALL_SENDED := 31, CALL_SEND_ERROR := 32, CALL_RECEIVING := 33, CALL_TERMINATED := 34, MODEM_SIGNAL_READING := 40, MODEM_SMS_DELETING := 60, MODEM_COMMAND_OK := 88, MODEM_COMMAND_ERR := 89 ) := MODEM_STANDBY; END_TYPE

This type enumerates the current status of generic MODEM function block.

Member

MODEM_STANDBY := 0

Modem is OFF in standby mode

MODEM_INIT := 1

Initialization of modem connection

NET_REGISTRATION := 2

Registration on the radio network

PPP_CONNECTING := 3

PPP connection in progress

MODEM_CONNECTED := 4

Modem connected to the service

PPP_LINK_LOST := 5

Page 94: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

93

Loss of the PPP link

MODEM_DCD_LOST := 6

Loss of DCD signal of the modem

MODEM_DEINIT := 7

Deinitialization of the modem

MODEM_RETRY_WAIT := 8

Waiting before reconnection

DYNDNS_REQUEST := 10

Updating request in progress

DYNDNS_OK := 11

IP address is updated on the server

DYNDNS_fail := 12

Update on the server failed

SMS_SENDING := 20

SMS sending in progress

SMS_SENDED := 21

SMS sent successfully

SMS_SEND_ERROR := 22

Error while sending the SMS

SMS_GETTING := 23

SMS getting in progress

SMS_RECEIVED := 24

Received and getted a SMS

SMS_NOT_RECEIVED := 25

No SMS available in reception

SMS_SEND_CONFIRMED := 26

Received SMS status report: delivered successfully

SMS_SEND_CONFIRMING := 27

Received SMS status report: temporary error, delivery will be retried

SMS_SEND_CONFIRM_ERR := 28

Received SMS status report: permanent error, delivery is not possible

CALL_SENDING := 30

Outgoing call in progress

CALL_SENDED := 31

Called device has answered to outgoing call

CALL_SEND_ERROR := 32

Page 95: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

94

Error while sending outgoing call

CALL_RECEIVING := 33

Incoming call in progress

CALL_TERMINATED := 34

Call has been terminated by caller/called (hang-up)

MODEM_SIGNAL_READING := 40

Updating the field strength of the radio network

MODEM_SMS_DELETING := 60

Deleting all SMS messages into SIM card

MODEM_COMMAND_OK := 88

Modem command executed correctly

MODEM_COMMAND_ERR := 89

Modem command executed with error

Page 96: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

95

1.11.6 DynDNS_Client

FUNCTION BLOCK DynDNS_Client

VAR_INPUT

Start : BOOL;

Server_Url : STRING(80);

User : STRING(20);

Password : STRING(20);

Hostname : STRING(50);

END_VAR

VAR_OUTPUT

Updated : BOOL;

Status : DYNDNS_STATUS;

Last_IP : STRING(15);

END_VAR

VAR

State : INT;

END_VAR

Function block of Dynamic DNS client for updating the IP address on Dynamic DNS server.

Input Variables

Start

Activation signal. If TRUE continuously checks if an IP update is required

Server_Url

Url of Dynamic DNS service. For dyndns.com is 'members.dyndns.org/nic/update'

User

Username of the account for the service of Dynamic DNS server

Password

Password of the account for the service of Dynamic DNS server

Hostname

Address of the connected device. Example: 'myplc.dyndns.org'

Output Variables

Updated

Result of the latest update

Status

Current status of the update

Last_IP

Last IP address registered into Dynamic DNS server

Internal Variables

State

Current status of the state graph for the function block

Comments

Page 97: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

96

This function block is maintaining its IP on a Dynamic DNS server as "dyndns.com", "no-ip.com" and others. After establishing a

connection with the Internet provider, it usually gives to the device a dynamic IP address that can vary each time.

To simplify access to the system from the outside, through the Internet, it's possible to communicate the current IP to a Dynamic DNS

server in order to make known to the whole network. In addition, the server performs an important function associatiating the IP

number to a symbolic name chosen for the device and easier to remember. In this way you can access the Web-server and FTP-

server of the system by typing the same address string, usually a third-level domain (for example: myplc.dyndns.org).

To use this service you must register, free of charge or with a small amount, at a provider of Dynamic DNS server, choosing a

username and password. After creating an account you must install on the server a Hostname (a specific equipment for which

perform the service). The Hostname coincides with the full address for the selected device. At this point the function block installs the

Dynamic DNS client which must be suitably configured to communicate with the server.

Server_Url parameter is the address where the server is available and this is characteristic of the service provider.

The User and Password are those chosen during registration to the service that usually involves managing of more Hosts.

Updating the IP in the server record, associated with the specific Host, is allowed only when the value of IP changes. For this, while

maintaining the function block permanently enabled, it will check continuously the variation of the current IP compared to the value

previously stored. Only in case of variation will provide a new request to the server to update its IP.

For each parameter not explicitly defined in the function block it uses the value in the CHIP.INI configuration file and, if not available in

that file, it uses a fixed default value:

Server_Url members.dyndns.org/nic/update User myplc_user Password myplc_password Hostname myplc.dyndns.org (myplc is the [DEVICE]NAME parameter value of CHIP.INI file)

The function block returns the current status of the update with one of the values defined by the DYNDNS_STATUS type:

Status = 0 Service is waiting for activation Status = 1 Updating request in progress Status = 2 IP address is updated on the server Status = 3 Update on the server failed Status = 4 Waiting before retry

The Last_IP output indicates the value of the last IP address permanently saved in CHIP.INI file.

Related Topics

DYNDNS_STATUS

Page 98: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

97

1.11.7 GM01_PPP

FUNCTION BLOCK GM01_PPP

VAR_INPUT

Start : BOOL;

Sim_Pin : STRING(12);

Auth : SINT;

User : STRING(20);

Password : STRING(20);

Connect_String : STRING(80);

Dial : STRING(20);

Retry_Seconds : INT;

END_VAR

VAR_OUTPUT

Ready : BOOL;

Status : MODEM_STATUS;

Signal : USINT;

END_VAR

VAR

State : INT;

Data_Service : MODEM_DATA_SERVICE;

My_IP : STRING(15);

Remote_IP : STRING(15);

Netmask : STRING(15);

DNS1 : STRING(15);

DNS2 : STRING(15);

Retry_Timer : INT;

END_VAR

Function block to establish a permanent Internet connection with PPP for GM01 modem.

Input Variables

Start

Activation signal. If FALSE starts the shutdown procedure

Sim_Pin

Pin code of the data SIM. Default is disabled

Auth

Authorization type: -1=undefined, 0=No, 1=PAP, 2=CHAP, 3=PAPPEER, 4=CHAPPEER

User

Username for the PPP connection. Required if Auth > 0

Password

Password for the PPP connection. Required if Auth > 0

Connect_String

Connection string with the APN. Example: 'AT+CGDCONT=1,"IP","ibox.tim.it"'

Dial

Call string with the dial number. Example: 'ATD*99***1#'

Retry_Seconds

Number of seconds before retrying the connection (-1=undefined)

Output Variables

Page 99: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

98

Ready

Connection ready flag. The Internet link is available

Status

Current status of the connection

Signal

Field strength of the radio network: 0=Min, 10=Max

Internal Variables

State

Current status of the state graph of the function block

Data_Service

Information about the Packet Data Service type of the connection

My_IP

IP address assigned by service provider

Remote_IP

Remote IP address of the peer to peer connection

Netmask

Netmask value for the subnet

DNS1

IP address of DNS server 1

DNS2

IP address of DNS server 2

Retry_Timer

Remaining time to the reconnection

Comments

This function block provides a permanent Internet connection using PPP with a modem of GM01 type. Refer to the documentation of

the target to verify the type of modem available.

The function block, once activated with the Start signal, starts a connection procedure that could, during certain phases, block the

execution of the POU for relatively long periods. When the connection is established shall enter into a permanent state with a

minimum processing time. For this reason, the function block must be inserted into a POU of the IEC program updated by a dedicated

task.

When the connection is established, the Ready output becomes TRUE and, from this moment, should be considered the execution of

other parts of the POU such as the activation of DynDNS_Client function block.

By setting the Start signal to FALSE, shall start a procedure for disabling the modem connection and shutdown.

The configuration parameters, passed as input to the function block, are not all necessary for the connection. Refer to specific settings

of the service provider. Moreover, for each parameter that is not explicitly defined in the function block, the value in the CHIP.INI

configuration file is used and, if not available in that file, it uses a fixed default value:

Sim_Pin disabled Auth 0=No User disabled Password disabled Connect_String AT+CGDCONT=1,"IP","ibox.tim.it" Dial ATD*99***1#

Page 100: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

99

Retry_Seconds 60

The function block returns the current state of the connection with one of the values defined by the MODEM_STATUS type:

Status = 0 Modem is OFF in standby mode Status = 1 Initialization of modem connection Status = 2 Registration on the network Status = 3 PPP connection in progress Status = 4 Modem connected to the service Status = 5 Loss of the PPP link Status = 6 Loss of DCD signal of the modem Status = 7 Deinitialization of the modem Status = 8 Waiting before reconnection

The Signal output indicates the field strength of the radio network.

NOTE: permanent PPP connection is useable as an alternative to other types of services like SMS management.

Related Topics

MODEM_DATA_SERVICE

MODEM_STATUS

DynDNS_Client

Page 101: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

100

1.11.8 GM01_PPP_SMS_Call

FUNCTION BLOCK GM01_PPP_SMS_Call

VAR_INPUT

Start : BOOL;

PPP_Disable : BOOL;

DynDNS_Enable : BOOL;

Retry_Seconds : INT;

Char_Set : MODEM_CHAR_SET;

SMS_Send_Start : BOOL;

SMS_Send_Phone : STRING(20);

SMS_Send_Text : STRING(160);

SMS_Send_Confirm : BOOL;

SMS_Send_Validity : UINT;

SMS_Get_Start : BOOL;

Call_Send_Start : BOOL;

Call_Send_Phone : STRING(20);

Call_Hang_Up : BOOL;

Command : MODEM_COMMAND;

Command_Data : STRING(300);

END_VAR

VAR_OUTPUT

Ready : BOOL;

Status : MODEM_STATUS;

Signal : USINT;

SMS_News : UINT;

SMS_Get_Time : STRING(32);

SMS_Get_Phone : STRING(20);

SMS_Get_Text : STRING(1536);

SMS_Confirm_ID : INT;

Call_Active : BOOL;

Call_ID_Phone : STRING(20);

Call_Rings : UINT;

Command_Replay : STRING(300);

END_VAR

VAR

State : INT;

Data_Service : MODEM_DATA_SERVICE;

My_IP : STRING(15);

Remote_IP : STRING(15);

Netmask : STRING(15);

DNS1 : STRING(15);

DNS2 : STRING(15);

Last_IP : STRING(15);

Retry_Timer : INT;

Retry_Counter : UDINT;

END_VAR

Function block to establish a permanent Internet connection with PPP for GM01 modem. Within the same radio connection all other services like

SMS and incoming/outgoing calls are allowable.

Input Variables

Start

Activation signal. If FALSE starts the shutdown procedure

PPP_Disable

Disable the PPP data connection allowing only SMS and Calls

DynDNS_Enable

Enable the DynDNS client function

Retry_Seconds

Page 102: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

101

Number of seconds before retrying the connection (-1=undefined)

Char_Set

Characters set used in text messages according to the MODEM_CHAR_SET type

SMS_Send_Start

Activation signal for sending SMS

SMS_Send_Phone

Phone number to send the SMS

SMS_Send_Text

Text of the SMS to be sent

SMS_Send_Confirm

Enable the request of delivery confirmation for a sending SMS

SMS_Send_Validity

Validity time for the delivery of a sent SMS (default 24h)

SMS_Get_Start

Activation signal for getting SMS

Call_Send_Start

Activation signal for sending an outgoing call

Call_Send_Phone

Phone number of outgoing call

Call_Hang_Up

Signal for incoming/outgoing call hang up

Command

Activation of a specific request to modem

Command_Data

Optional data for a specific request to modem

Output Variables

Ready

Connection ready flag. The Internet link is available

Status

Current status of the connection

Signal

Field strength of the radio network: 0=Min, 10=Max

SMS_News

Number of new SMS available

SMS_Get_Time

Time of receipt of the SMS

Page 103: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

102

SMS_Get_Phone

Telephone number of the sender of the SMS

SMS_Get_Text

Text of the SMS received

SMS_Confirm_ID

Reference ID number for the delivery confirmation of sent SMS

Call_Active

An incoming call is active (bell is ringing)

Call_ID_Phone

Telephone number of the caller (ID)

Call_Rings

Number of rings detected for the incoming call

Command_Replay

Modem replay to a specific command code

Internal Variables

State

Current status of the state graph of the function block

Data_Service

Information about the Packet Data Service type of the connection

My_IP

IP address assigned by service provider

Remote_IP

Remote IP address of the peer to peer connection

Netmask

Netmask value for the subnet

DNS1

IP address of DNS server 1

DNS2

IP address of DNS server 2

Last_IP

Currently registered IP address on DynDNS server

Retry_Timer

Remaining time to the reconnection

Retry_Counter

Counting of connection retries

Page 104: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

103

Comments

This function block combines, in a single central control, all the operations carried out by a modem of GM01 type. Refer to the

documentation of the target to verify the type of modem available.

The function block, once activated with the Start signal, starts a connection procedure that could, during certain phases, block the

execution of the POU for relatively long periods. When the connection is established shall enter into a permanent state with a

minimum processing time. For this reason, the function block must be inserted into a POU of the IEC program updated by a dedicated

task.

The Ready output signal indicates that the modem is connected and the Status output variable assumes the MODEM_CONNECTED

value.

The Signal output variable indicates the field strength of the radio connection.

By setting the Start signal to FALSE, shall start a procedure for disabling the modem connection and shutdown.

The PPP data connection is set by default but can be disabled forcing PPP_Disable input signal to TRUE value. This allows the use of

function block only for SMS and calls.

If the data connection is enabled, the default address of device gateway is redefined using the IP value provided by the network

operator, allowing a permanent radio connection to the Internet.

If DynDNS_Enable signal is active, as soon as the PPP connection is established, a new update of IP address on DynDNS server is

also executed.

When the modem is connected, the SMS send/receive services can be executed.

The SMS_Send_Start input signal forces the graph of the function block in the state of sending the SMS according to the previously

prepared data. The result of the operation is indicated by the value of the Status output variable. The SMS_Send_Start signal can be

forced also for only one cycle and should be resetted to return to idle state waiting for a new command.

The SMS_Send_Confirm signal enables the request of delivery confirmation for the SMS to be sent and the SMS_Send_Validity

parameter specifies the validity time of the sent SMS according to the following table:

The SMS_Get_Start input signal forces the graph of the function block in the state of the received SMS extraction. The Status output

variable indicates the availability or not of an SMS in reception and the data of a new SMS are available in the respective output

variables. The SMS_Get_Start signal can be forced also for only one cycle and should be resetted to return to idle state waiting for a

new command.

The SMS_News output variable indicates the current availability of new incoming messages.

If the received SMS is a delivery confirmation of a previously sent SMS, the Status variable will assumes a related value to

differentiate it from the receipt of a normal SMS.

The SMS_Confirm_ID output value is generated by sending a SMS for which delivery confirmation is required and this value must be

used as reference after the receipt of a delivery confirmation SMS.

In the state of modem connected the monitoring of any incoming call is always active.

During the entire duration of the incoming call, the Call_Active signal is TRUE, indicating the bell ringing. If the service is enabled to

recognize the caller ID, its telephone number is forced into the Call_ID_Phone output variable. The number of rings received is

counted in the Call_Rings output variable. When the caller hangs up the call, Call_Active output returns to FALSE, leaving in memory

the phone number and the rings counter until the next call. To terminate an incoming call, before the caller hung up, activate, even for

a single cycle, the Call_Hang_Up input variable and then reset it inactive.

To make an outgoing call should be set up phone number in the Call_Send_Phone input variable and activate the Call_Send_Start

signal.

If the remote device answers the call, the status of the graph goes to Call_SENDED. If the called device hangs up the call or does not

answer or is busy, the state, after the transition to the CALL_TERMINATED value, return to MODEM_CONNECTED.

To terminate the outgoing call by the caller, the Call_Hang_Up input signal must be activated. Both Call_Send_Phone and

Call_Hang_Up variables must be activated for at least one cycle and then reforced to inactive value FALSE.

Page 105: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

104

Finally in the state of service activated, also some specific modem functions can be executed forcing a command code in the

Command input variable. The Command_Data input variable can supply also an optional data string specific for the command type.

Any information replayed by the modem is shown in the Command_Replay output variable. For example, the

MODEM_SIGNAL_READ command code allows the updating of Signal output value that indicates the signal strength of the radio

network.

NOTE: all the configuration parameters of the modem, not explicitly defined in the function block, are taken from the CHIP.INI file.

Related Topics

MODEM_CHAR_SET

MODEM_COMMAND

MODEM_DATA_SERVICE

MODEM_STATUS

Page 106: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

105

1.11.9 GM01_SMS

FUNCTION BLOCK GM01_SMS

VAR_INPUT

Start : BOOL;

Sim_Pin : STRING(12);

Char_Set : MODEM_CHAR_SET;

SMS_Send_Start : BOOL;

SMS_Send_Phone : STRING(20);

SMS_Send_Text : STRING(160);

SMS_Get_Start : BOOL;

END_VAR

VAR_OUTPUT

Ready : BOOL;

Status : MODEM_STATUS;

Signal : USINT;

SMS_Get_Time : STRING(32);

SMS_Get_Phone : STRING(20);

SMS_Get_Text : STRING(1536);

END_VAR

VAR

State : INT;

END_VAR

Function block for handling SMS send/receive with GM01 modem.

Input Variables

Start

Activation signal. If FALSE starts the shutdown procedure

Sim_Pin

Pin code of the SIM. Default is disabled

Char_Set

Characters set used in text messages according to the MODEM_CHAR_SET type

SMS_Send_Start

Activation signal for sending SMS

SMS_Send_Phone

Phone number to send the SMS

SMS_Send_Text

Text of the SMS to be sent

SMS_Get_Start

Activation signal for getting SMS

Output Variables

Ready

SMS service ready flag

Status

Current status of the SMS management

Page 107: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

106

Signal

Field strength of the radio network: 0=Min, 10=Max

SMS_Get_Time

Time of receipt of the SMS

SMS_Get_Phone

Telephone number of the sender of the SMS

SMS_Get_Text

Text of the SMS received

Internal Variables

State

Current status of the state graph of the function block

Comments

This function block allows the management of SMS send/receive using a modem of GM01 type. Refer to the documentation of the

target to verify the type of modem available.

The function block, once activated with the Start signal, starts a connection procedure that could, during certain phases, block the

execution of the POU for relatively long periods. When the connection is established shall enter into a permanent state with a

minimum processing time. For this reason, the function block must be inserted into a POU of the IEC program updated by a dedicated

task.

When the SMS service is activated, the Ready output becomes TRUE and, from this moment, should be considered the execution of

other parts of the POU. By setting the Start signal to FALSE, shall start a procedure for disabling the modem connection and

shutdown.

If the Sim_Pin configuration parameter is not explicitly defined in the function block, the value in the CHIP.INI configuration file is used

and, if not available in that file, it uses the disabled value.

The function block returns the current state of the service with one of the values defined by the MODEM_STATUS type:

Status = 0 Modem is OFF in standby mode Status = 1 Initialization of modem connection Status = 4 Modem connected to the service Status = 7 Deinitialization of the modem Status = 20 SMS sending in progress Status = 21 SMS sent successfully Status = 22 Error while sending the SMS Status = 23 SMS getting in progress Status = 24 Received and getted an SMS Status = 25 No SMS available in reception

When this function block is in the state of the activated service, it awaits the request of a command to send SMS or extract a received

SMS. The SMS_Send_Start input signal forces the graph of the block in the state of sending the SMS according to the previously

prepared data. The result of the operation is indicated by the value of the Status output variable. Then the SMS_Send_Start signal

must be put back inactive to return in the idle state waiting for a new command.

The SMS_Get_Start input signal force the graph of the block in the state of the received SMS extraction. The Status output variable

indicates the availability or not of an SMS in reception and the data of a new SMS are available in the respective output variables.

Then the SMS_Get_Start signal must be put back inactive to return in the idle state waiting for a new command. To receive more

incoming SMS the SMS_Get_Start signal must be activated periodically checking the reception via the Status output value.

The Signal output indicates the field strength of the radio network.

NOTE: SMS management is useable as an alternative to other types of services like permanent PPP connection.

Related Topics

MODEM_CHAR_SET

Page 108: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

107

MODEM_STATUS

Page 109: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

108

1.12 The TCPIP library (TCPIP_Lib.lib)

This library offers the functions for the TCPIP applications.

Here is a list of all the functions this library offers:

TYPE FTP_COMMAND

TYPE HTTP_MODE

TYPE TCPIP_ERROR

DNS_Client

FTP_Client

HTTP_Client

HTTP_Get

HTTP_Post

SendMail

SendPing

SMTP_Client

SNTP_DateTime

Page 110: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

109

1.12.1 FTP_COMMAND

TYPE FTP_COMMAND

TYPE FTP_COMMAND : ( FTP_NO_COMMAND := 0, FTP_SEND_FILE := 1, FTP_RECEIVE_FILE := 2, FTP_RENAME_FILE := 3, FTP_DELETE_FILE := 4, FTP_GET_FILE_SIZE := 5, FTP_SET_DIRECTORY := 11, FTP_GET_DIRECTORY := 12, FTP_CREATE_DIRECTORY := 13, FTP_DELETE_DIRECTORY := 14 ) := FTP_NO_COMMAND; END_TYPE

This type enumerates the commands of FTP client.

Member

FTP_NO_COMMAND := 0

No command requested (standby value)

FTP_SEND_FILE := 1

Copy a file on client to server

FTP_RECEIVE_FILE := 2

Copy a file on server to client

FTP_RENAME_FILE := 3

Rename a file on server

FTP_DELETE_FILE := 4

Delete a file on server

FTP_GET_FILE_SIZE := 5

Read the size (bytes) of server file

FTP_SET_DIRECTORY := 11

Set the current working directory of server

FTP_GET_DIRECTORY := 12

Read the current working directory of server

FTP_CREATE_DIRECTORY := 13

Create a new directory on server

FTP_DELETE_DIRECTORY := 14

Delete a directory on server

Page 111: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

110

1.12.2 HTTP_MODE

TYPE HTTP_MODE

TYPE HTTP_MODE : ( GET_HTTP10 := 0, POST_HTTP10 := 1, HEAD_HTTP10 := 2, PUT_HTTP10 := 3, DELETE_HTTP10 := 4, GET_HTTP11 := 16, POST_HTTP11 := 17, HEAD_HTTP11 := 18, PUT_HTTP11 := 19, DELETE_HTTP11 := 20 ) := GET_HTTP10; END_TYPE

This type enumerates the modalities of HTTP client.

Member

GET_HTTP10 := 0

HTTP request with Get method, HHTP protocol V1.0

POST_HTTP10 := 1

HTTP request with Post method, HHTP protocol V1.0

HEAD_HTTP10 := 2

HTTP request with Head method, HHTP protocol V1.0

PUT_HTTP10 := 3

HTTP request with Put method, HHTP protocol V1.0

DELETE_HTTP10 := 4

HTTP request with Delete method, HHTP protocol V1.0

GET_HTTP11 := 16

HTTP request with Get method, HHTP protocol V1.1

POST_HTTP11 := 17

HTTP request with Post method, HHTP protocol V1.1

HEAD_HTTP11 := 18

HTTP request with Head method, HHTP protocol V1.1

PUT_HTTP11 := 19

HTTP request with Put method, HHTP protocol V1.1

DELETE_HTTP11 := 20

HTTP request with Delete method, HHTP protocol V1.1

Page 112: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

111

1.12.3 TCPIP_ERROR

TYPE TCPIP_ERROR

TYPE TCPIP_ERROR : ( TCPIP_NO_ERR := 0, TCPIP_DNS_ILLEGAL_ARG := -1, TCPIP_DNS_RESOURCE_LACK := -2, TCPIP_DNS_SERVER_UNREACH := -3, TCPIP_DNS_NO_RESOLUTION := -4, TCPIP_PKI_CERT_BADCERT := 1, TCPIP_PKI_CERT_REVOKED := 2, TCPIP_PKI_CERT_EXPIRED := 4, TCPIP_PKI_CERT_UNMATCHED := 8, TCPIP_PKI_CERT_UNKNOWNCA := 16, TCPIP_PKI_CERT_NOTVERIFIED := 32, TCPIP_SSL_HANDSHAKE_FAILED := 64, TCPIP_SSL_HANDSHAKE_TIMEOUT:= 65, TCPIP_BAD_PARAMETER := 100, TCPIP_CONNECTION_TIMEOUT := 101, TCPIP_RECEIVE_OVERFLOW := 102, TCPIP_OP_NOT_ALLOWED := 201, TCPIP_NO_SUCH_FILE_DIR := 202, TCPIP_NO_SUCH_PROCESS := 203, TCPIP_INTERRUPTED_CALL := 204, TCPIP_IN_OUT_ERR := 205, TCPIP_DEVICE_NOT_CONF := 206, TCPIP_BAD_FILE_DESC := 209, TCPIP_NO_CHILD_PROC := 210, TCPIP_NO_ALLOC_MEMORY := 211, TCPIP_PERMISSION_DENIED := 213, TCPIP_BAD_ADDRESS := 214, TCPIP_FILE_EXISTS := 217, TCPIP_OP_NOT_SUPP_BY_DEVICE := 219, TCPIP_NOT_A_DIRECTORY := 220, TCPIP_IS_A_DIRECTORY := 221, TCPIP_INVALID_ARGUMENT := 222, TCPIP_NO_RES_AVAILABLE := 224, TCPIP_OP_WOULD_BLOCK := 235, TCPIP_OP_NOW_PROGRESS := 236, TCPIP_OP_ALREADY_PROGRESS := 237, TCPIP_SOCK_OP_ON_NON_SOCK := 238, TCPIP_DEST_ADD_REQUIRED := 239, TCPIP_MESSAGE_TOO_LONG := 240, TCPIP_WRONG_SOCK_PROTO := 241, TCPIP_PROTO_NOT_AVAILABLE := 242, TCPIP_PROTO_NOT_SUPPORTED := 243, TCPIP_SOCK_NOT_SUPPORTED := 244, TCPIP_OP_NOT_SUPPORTED := 245, TCPIP_PROTO_FAM_NOT_SUPP := 246, TCPIP_ADD_FAM_NOT_SUPP := 247, TCPIP_ADD_ALREADY_USED := 248, TCPIP_ADD_NOT_ASSIGNABLE := 249, TCPIP_NET_IS_DOWN := 250, TCPIP_NET_IS_UNREACHABLE := 251, TCPIP_NET_DROPPED_CONN := 252, TCPIP_SOFTWARE_CONN_ABORT := 253, TCPIP_CONN_RESET_BY_PEER := 254, TCPIP_NO_BUF_AVAILABLE := 255, TCPIP_SOCK_ALREADY_CONN := 256, TCPIP_SOCK_NOT_CONN := 257,

Page 113: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

112

TCPIP_SOCKET_SHUTDOWN := 258, TCPIP_TOO_MANY_REFER := 259, TCPIP_OP_TIMEOUT := 260, TCPIP_CONN_REFUSED := 261, TCPIP_HOST_IS_DOWN := 264, TCPIP_NO_ROUTE_TO_HOST := 265, TCPIP_HTTP_BAD_PARAMETER := 1000, TCPIP_HTTP_BAD_ERR_CODE := 1001, TCPIP_HTTP_CONTINUE := 1100, TCPIP_HTTP_SWITCH_PROTO := 1101, TCPIP_HTTP_OK := 1200, TCPIP_HTTP_CREATED := 1201, TCPIP_HTTP_ACCEPTED := 1202, TCPIP_HTTP_NON_AUTH_INFO := 1203, TCPIP_HTTP_NO_CONTENT := 1204, TCPIP_HTTP_RESET_CONTENT := 1205, TCPIP_HTTP_PARTIAL_CONTENT := 1206, TCPIP_HTTP_MULTI_CHOICES := 1300, TCPIP_HTTP_MOVED_PERMANENTLY := 1301, TCPIP_HTTP_FOUND := 1302, TCPIP_HTTP_SEE_OTHER := 1303, TCPIP_HTTP_NOT_MODIFIED := 1304, TCPIP_HTTP_USE_PROXY := 1305, TCPIP_HTTP_TEMP_REDIRECT := 1307, TCPIP_HTTP_BAD_REQUEST := 1400, TCPIP_HTTP_UNAUTHORIZED := 1401, TCPIP_HTTP_PAYMENT_REQ := 1402, TCPIP_HTTP_FORBIDDEN := 1403, TCPIP_HTTP_NOT_FOUND := 1404, TCPIP_HTTP_METHOD_NOT_ALLOW := 1405, TCPIP_HTTP_NOT_ACCEPTABLE := 1406, TCPIP_HTTP_PROXY_AUTH_REQ := 1407, TCPIP_HTTP_REQUEST_TIMEOUT := 1408, TCPIP_HTTP_CONFLICT := 1409, TCPIP_HTTP_GONE := 1410, TCPIP_HTTP_LENGTH_REQUIRED := 1411, TCPIP_HTTP_PRECOND_REQUIRED := 1412, TCPIP_HTTP_REQ_ENT_TOO_LARGE := 1413, TCPIP_HTTP_REQ_URI_TOO_LARGE := 1414, TCPIP_HTTP_UNSUPP_MEDIA_TYPE := 1415, TCPIP_HTTP_RANGE_NO_SATISFABLE := 1416, TCPIP_HTTP_EXPECTATION_FAILED := 1417, TCPIP_HTTP_UNPROCESSABLE_ENTITY := 1422, TCPIP_HTTP_INTERN_SERVER_ERR := 1500, TCPIP_HTTP_NOT_IMPLEMENTED := 1501, TCPIP_HTTP_BAD_GATEWAY := 1502, TCPIP_HTTP_SERVICE_UNAVAILABLE := 1503, TCPIP_HTTP_GATEWAY_TIMEOUT := 1504, TCPIP_HTTP_VERSION_NOT_SUPP := 1505, TCPIP_SMTP_RECV_LINE := 2000, TCPIP_SMTP_RECV_LAST := 2001, TCPIP_SMTP_TEXT_TOO_LARGE := 2100, TCPIP_SMTP_NO_AUTH_DEFINE := 2101, TCPIP_SMTP_UNKNOWN_AUTH := 2102, TCPIP_SMTP_BAD_CRAM_MD5 := 2103, TCPIP_SMTP_FILE_NOT_FOUND := 2104, TCPIP_SMTP_FILE_READ_ERR := 2105, TCPIP_SMTP_FILE_SEND_ERR := 2106, TCPIP_FTP_SSL_CREATE_ERR := 3000, TCPIP_FTP_OPEN_CONNECTION_ERR := 3001, TCPIP_FTP_AUTH_COMMAND_ERR := 3002, TCPIP_FTP_LOGIN_ERR := 3003,

Page 114: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

113

TCPIP_FTP_PROT_COMMAND_ERR := 3004, TCPIP_FTP_COMMAND_EXECUTE_ERR := 3005, TCPIP_FTP_LOGOUT_ERR := 3006, TCPIP_FTP_SSL_CLOSE_ERR := 3007 ) := TCPIP_NO_ERR; END_TYPE

This type enumerates the errors code values for TCP/IP communication.

Member

TCPIP_NO_ERR := 0

Operation executed without errors

TCPIP_DNS_ILLEGAL_ARG := -1

An argument with an invalid value was passed

TCPIP_DNS_RESOURCE_LACK := -2

Lack of a resource such as memory or sockets

TCPIP_DNS_SERVER_UNREACH := -3

No name server could be reached

TCPIP_DNS_NO_RESOLUTION := -4

No resolution could be found

TCPIP_PKI_CERT_BADCERT := 1

Critical error

TCPIP_PKI_CERT_REVOKED := 2

Revoked certiticate

TCPIP_PKI_CERT_EXPIRED := 4

Expired certificate

TCPIP_PKI_CERT_UNMATCHED := 8

Identity not matched

TCPIP_PKI_CERT_UNKNOWNCA := 16

CA is unknown

TCPIP_PKI_CERT_NOTVERIFIED := 32

The mentioned CA fails to verify the certificate

TCPIP_SSL_HANDSHAKE_FAILED := 64

SSL handshake process failed

TCPIP_SSL_HANDSHAKE_TIMEOUT := 65

SSL handshake process timeout

TCPIP_BAD_PARAMETER := 100

Passed a bad parameter to the function / function block

TCPIP_CONNECTION_TIMEOUT := 101

Connection or send/recv timeout

Page 115: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

114

TCPIP_RECEIVE_OVERFLOW := 102

Receiving buffer overflow

TCPIP_OP_NOT_ALLOWED := 201

Operation not permitted

TCPIP_NO_SUCH_FILE_DIR := 202

No such file or directory

TCPIP_NO_SUCH_PROCESS := 203

No such process

TCPIP_INTERRUPTED_CALL := 204

Interrupted system call

TCPIP_IN_OUT_ERR := 205

Input/output error

TCPIP_DEVICE_NOT_CONF := 206

Device not configured

TCPIP_BAD_FILE_DESC := 209

Bad file descriptor

TCPIP_NO_CHILD_PROC := 210

No child processes

TCPIP_NO_ALLOC_MEMORY := 211

Cannot allocate memory

TCPIP_PERMISSION_DENIED := 213

Permission denied

TCPIP_BAD_ADDRESS := 214

Bad address

TCPIP_FILE_EXISTS := 217

File exists

TCPIP_OP_NOT_SUPP_BY_DEVICE := 219

Operation not supported by device

TCPIP_NOT_A_DIRECTORY := 220

Not a directory

TCPIP_IS_A_DIRECTORY := 221

Is a directory

TCPIP_INVALID_ARGUMENT := 222

Invalid argument

TCPIP_NO_RES_AVAILABLE := 224

No resource available

Page 116: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

115

TCPIP_OP_WOULD_BLOCK := 235

Operation would block

TCPIP_OP_NOW_PROGRESS := 236

Operation now in progress

TCPIP_OP_ALREADY_PROGRESS := 237

Operation already in progress

TCPIP_SOCK_OP_ON_NON_SOCK := 238

Socket operation on non-socket

TCPIP_DEST_ADD_REQUIRED := 239

Destination address required

TCPIP_MESSAGE_TOO_LONG := 240

Message too long

TCPIP_WRONG_SOCK_PROTO := 241

Protocol wrong type for socket

TCPIP_PROTO_NOT_AVAILABLE := 242

Protocol not available

TCPIP_PROTO_NOT_SUPPORTED := 243

Protocol not supported

TCPIP_SOCK_NOT_SUPPORTED := 244

Socket type not supported

TCPIP_OP_NOT_SUPPORTED := 245

Operation not supported

TCPIP_PROTO_FAM_NOT_SUPP := 246

Protocol family not supported

TCPIP_ADD_FAM_NOT_SUPP := 247

Address family not supported by protocol family

TCPIP_ADD_ALREADY_USED := 248

Address already in use

TCPIP_ADD_NOT_ASSIGNABLE := 249

Can't assign requested address

TCPIP_NET_IS_DOWN := 250

Network is down

TCPIP_NET_IS_UNREACHABLE := 251

Network is unreachable

TCPIP_NET_DROPPED_CONN := 252

Network dropped connection on reset

Page 117: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

116

TCPIP_SOFTWARE_CONN_ABORT := 253

Software caused connection abort

TCPIP_CONN_RESET_BY_PEER := 254

Connection reset by peer

TCPIP_NO_BUF_AVAILABLE := 255

No buffer space available

TCPIP_SOCK_ALREADY_CONN := 256

Socket is already connected

TCPIP_SOCK_NOT_CONN := 257

Socket is not connected

TCPIP_SOCKET_SHUTDOWN := 258

Can't send/receive after socket shutdown. There is no more data to be received.

TCPIP_TOO_MANY_REFER := 259

Too many references: can't splice

TCPIP_OP_TIMEOUT := 260

Operation timed out

TCPIP_CONN_REFUSED := 261

Connection refused

TCPIP_HOST_IS_DOWN := 264

Host is down

TCPIP_NO_ROUTE_TO_HOST := 265

No route to host

TCPIP_HTTP_BAD_PARAMETER := 1000

Received a replay with bad parameters

TCPIP_HTTP_BAD_ERR_CODE := 1001

Received a replay with bad error code

TCPIP_HTTP_CONTINUE := 1100

Continue

TCPIP_HTTP_SWITCH_PROTO := 1101

Switching protocols

TCPIP_HTTP_OK := 1200

OK

TCPIP_HTTP_CREATED := 1201

Created

TCPIP_HTTP_ACCEPTED := 1202

Accepted

Page 118: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

117

TCPIP_HTTP_NON_AUTH_INFO := 1203

Non-authoritative information

TCPIP_HTTP_NO_CONTENT := 1204

No content

TCPIP_HTTP_RESET_CONTENT := 1205

Reset content

TCPIP_HTTP_PARTIAL_CONTENT := 1206

Partial content

TCPIP_HTTP_MULTI_CHOICES := 1300

Multiple choices

TCPIP_HTTP_MOVED_PERMANENTLY := 1301

Moved permanently

TCPIP_HTTP_FOUND := 1302

Found

TCPIP_HTTP_SEE_OTHER := 1303

See other

TCPIP_HTTP_NOT_MODIFIED := 1304

Not modified

TCPIP_HTTP_USE_PROXY := 1305

Use proxy

TCPIP_HTTP_TEMP_REDIRECT := 1307

Temporary redirect

TCPIP_HTTP_BAD_REQUEST := 1400

Bad request

TCPIP_HTTP_UNAUTHORIZED := 1401

Unauthorized

TCPIP_HTTP_PAYMENT_REQ := 1402

Payment required

TCPIP_HTTP_FORBIDDEN := 1403

Forbidden

TCPIP_HTTP_NOT_FOUND := 1404

Not found

TCPIP_HTTP_METHOD_NOT_ALLOW := 1405

Method not allowed

TCPIP_HTTP_NOT_ACCEPTABLE := 1406

Not acceptable

Page 119: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

118

TCPIP_HTTP_PROXY_AUTH_REQ := 1407

Proxy authentication required

TCPIP_HTTP_REQUEST_TIMEOUT := 1408

Request timeout

TCPIP_HTTP_CONFLICT := 1409

Conflict

TCPIP_HTTP_GONE := 1410

Gone

TCPIP_HTTP_LENGTH_REQUIRED := 1411

Length required

TCPIP_HTTP_PRECOND_REQUIRED := 1412

Precondition failed

TCPIP_HTTP_REQ_ENT_TOO_LARGE := 1413

Request entity too large

TCPIP_HTTP_REQ_URI_TOO_LARGE := 1414

Request URI too large

TCPIP_HTTP_UNSUPP_MEDIA_TYPE := 1415

Unsupported media type

TCPIP_HTTP_RANGE_NO_SATISFABLE := 1416

Requested range not satisfiable

TCPIP_HTTP_EXPECTATION_FAILED := 1417

Expectation failed

TCPIP_HTTP_UNPROCESSABLE_ENTITY := 1422

Unprocessable entity

TCPIP_HTTP_INTERN_SERVER_ERR := 1500

Internal server error

TCPIP_HTTP_NOT_IMPLEMENTED := 1501

Not implemented

TCPIP_HTTP_BAD_GATEWAY := 1502

Bad gateway

TCPIP_HTTP_SERVICE_UNAVAILABLE := 1503

Service unavailable

TCPIP_HTTP_GATEWAY_TIMEOUT := 1504

Gateway timeout

TCPIP_HTTP_VERSION_NOT_SUPP := 1505

HTTP version not supported

Page 120: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

119

TCPIP_SMTP_RECV_LINE := 2000

Received unexpected intermedie line

TCPIP_SMTP_RECV_LAST := 2001

Received unexpected last line

TCPIP_SMTP_TEXT_TOO_LARGE := 2100

Text of E-mail too large

TCPIP_SMTP_NO_AUTH_DEFINE := 2101

No username/password defined

TCPIP_SMTP_UNKNOWN_AUTH := 2102

Unknown authorization request from server

TCPIP_SMTP_BAD_CRAM_MD5 := 2103

Bad CRAM-MD5 received from server

TCPIP_SMTP_FILE_NOT_FOUND := 2104

Attached file not found

TCPIP_SMTP_FILE_READ_ERR := 2105

Error while reading attached file

TCPIP_SMTP_FILE_SEND_ERR := 2106

Error while sending attached file

TCPIP_FTP_SSL_CREATE_ERR := 3000

SSL session create error

TCPIP_FTP_OPEN_CONNECTION_ERR := 3001

FTP connection error

TCPIP_FTP_AUTH_COMMAND_ERR := 3002

AUTH command error in FTP connection

TCPIP_FTP_LOGIN_ERR := 3003

Login error while connecting to FTP server

TCPIP_FTP_PROT_COMMAND_ERR := 3004

PROT command error in FTP connection

TCPIP_FTP_COMMAND_EXECUTE_ERR := 3005

FTP command execution error

TCPIP_FTP_LOGOUT_ERR := 3006

Error while logout from FTP connection

TCPIP_FTP_SSL_CLOSE_ERR := 3007

SSL session close error

Page 121: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

120

1.12.4 DNS_Client

FUNCTION BLOCK DNS_Client

VAR_INPUT

Start : BOOL;

DNS_Server : STRING(15);

Domain_Name : STRING(80);

END_VAR

VAR_OUTPUT

End : BOOL;

Error : TCPIP_ERROR;

IP_Addr_1 : STRING(15);

IP_Addr_2 : STRING(15);

END_VAR

VAR

State : INT;

END_VAR

Function block for the resolution of the IP address from domain name.

Input Variables

Start

Signal for activation of function block

DNS_Server

Additional DNS server (15 max characters)

Domain_Name

Domain name to be resolved (80 max characters)

Output Variables

End

End of requested operation

Error

Result of the execution (0=OK, 0 error code)

IP_Addr_1

First IP address obtained (15 max characters)

IP_Addr_2

Second IP address obtained (15 max characters)

Internal Variables

State

Current status of the state graph of the function block

Comments

This function block allows to send a request as DNS client to a specific DNS server or to the default DNS servers in the system.

The function block is realized with a state graph combined with a dedicated task, internal to the Run Time System. This allows the

insertion of the block in the POU without increasing the scan time of other parts of the program even lower priority.

The DNS_Server parameter allows to add a DNS server with greater priority over those set in the CHIP.INI configuration file or the

Page 122: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

121

one provided by the PPP or the one provided by the DHCP server.

The Domain_Name parameter is the name to be resolved to its IP address. If the name is already an IP address in the form

xxx.xxx.xxx.xxx, the block doesn't executes the request and returns the same IP string on the output.

The request to the server begins after the Start signal. At the end of the operation, the End output signal is activated and the Error

output value reports the status.

The request can return up two IP addresses saving them into IP_Addr_1 and IP_Addr_2 output strings.

NOTE: the operating system manages a DNS cache that avoids the request to the server if the IP address has not yet expired.

The function block returns the operation result with Error output variable as follows:

0 : success

-1: An argument with an invalid value was passed

-2: Lack of a resource such as memory or sockets

-3: No name server could be reached

-4: No resolution could be found

Related Topics

TCPIP_ERROR

Page 123: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

122

1.12.5 FTP_Client

FUNCTION BLOCK FTP_Client

VAR_INPUT

Start : BOOL;

Server_Name : STRING(80);

Server_Port : UINT := 21;

Username : STRING(30);

Password : STRING(30);

Passive : BOOL;

Command : INT;

Path_File_1 : POINTER TO STRING;

Path_File_2 : POINTER TO STRING;

Timeout : UINT := 5000;

SSL_Enable : BOOL;

SSL_Cacert: STRING(80);

END_VAR

VAR_OUTPUT

Logged : BOOL;

Done : BOOL;

Error : TCPIP_ERROR;

END_VAR

VAR

State : INT;

END_VAR

Function block to execute commands as FTP client.

Input Variables

Start

Signal for activation of function block

Server_Name

Name of the FTP server (max 80 characters)

Server_Port

Port address of the server (optional, default 21)

Username

Username to log in the FTP server (maximum 30 characters)

Password

Password to log in the FTP server (maximum 30 characters)

Passive

Enable passive mode for data transfer (default active mode)

Command

Code value of command to be executed

Path_File_1

Name of source Path or File (starting Path/File)

Path_File_2

Name of destination Path or File (ending Path/File)

Page 124: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

123

Timeout

Maximum wait timeout (ms, default 5000)

SSL_Enable

SSL secure connection enable

SSL_Cacert

SSL certificate file path (80 max characters)

Output Variables

Logged

Connected to server, ready for commands

Done

Command executed

Error

Result of the execution (0=OK, 0 error code)

Internal Variables

State

Current status of the state graph of the function block

Comments

This function block allows to run one or more client commands on a remote FTP server.

The function block is realized with a state graph combined with a dedicated task, internal to the Run Time System. This allows the

insertion of the block in the POU without increasing the scan time of other parts of the program even lower priority.

Server_Name, Server_Port, Username and Password parameters must match those of the account on the FTP server. The server

name can be expressed in numerical form xxx.xxx.xxx.xxx or by the domain name. In this case the IP address is resolved by the

internal DNS client.

Server_Port parameter sets the port used for the FTP protocol commands, usually the default value 21.

Passive parameter enables passive mode for data exchange. The default value (FALSE) is the active mode. Consider that the active

mode has advantages on the server side relatively to connection problems due to its Firewall.

To connect to a secure server SSL_Enable parameter must be TRUE and the certificate file path must be specified into SSL_Cacert

parameter. The secure FTPS connection is established explicitly on TLS/SSL protocol by sending the AUTH command.

The connection to the server is activated by the Start signal. After the authentication phase, the Logged output signal is activated and

the client remains connected until the start signal returns to FALSE.

The Timeout defines the maximum wait for the connection or response.

During the Logged state, the Command parameter allows to send one or more commands to the server, sequentially setting a control

code depending on the FTP_COMMAND data type. After each variation of the value, the command is performed using one or both of

the input variables of pointer to string type. Commands that require to specify a single path/file name use the first Path_File_1 pointer,

while the commands that operate a transfer or name change use always Path_File_1 as origin and Path_File_2 as destination.

The implemented commands are:

FTP_NO_COMMAND (0) No command requested FTP_SEND_FILE (1) Copy a file on client to server Path_File_1 (client) -> Path_File_2 (server) FTP_RECEIVE_FILE (2) Copy a file on server to client Path_File_1 (server) -> Path_File_2 (client) FTP_RENAME_FILE (3) Rename a file on server Path_File_1 (old name) -> Path_File_2 (new name) FTP_DELETE_FILE (4) Delete a file on server

Page 125: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

124

Path_File_1 (server file) FTP_GET_FILE_SIZE (5) Read the size (bytes) of server file Path_File_1 (server) -> Path_File_2 (file size) FTP_SET_DIRECTORY (11) Set the current working directory of server Path_File_1 (server directory) FTP_GET_DIRECTORY (12) Read the current working directory of server Path_File_1 (server directory) FTP_CREATE_DIRECTORY (13) Create a new directory on server Path_File_1 (server directory) FTP_DELETE_DIRECTORY (14) Delete a directory on server Path_File_1 (server directory) The Done output variable indicates the end of command execution. To run a single command, the Command value can also be set

before the starting of connection using Start signal. In this way the operation can be executed only activating the Start signal and

waiting for the end with the Done signal. At this point, the Start signal can be deactivated.

The function block returns the operation result with Error output variable as follows:

0 : success

-1...-4: DNS client error

1/2/4/8/16/32/64/65: SSL functions error

101: TCP/IP receive timeout

102: TCP/IP receive overflow

201...265: TCP/IP functions error

3000: SSL session create error

3001: FTP connection error

3002: AUTH command error in FTP connection

3003: Login error while connecting to FTP server

3004: PROT command error in FTP connection

3005: FTP command execution error

3006: Error while logout from FTP connection

3007: SSL session close error

Related Topics

FTP_COMMAND

TCPIP_ERROR

Page 126: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

125

1.12.6 HTTP_Client

FUNCTION BLOCK HTTP_Client

VAR_INPUT

Start : BOOL;

Header_Extra : POINTER TO STRING;

Mode : INT;

Username : STRING(30);

Password : STRING(30);

Host_Name : STRING(80);

Host_Port : UINT;

Path : STRING(80);

Query : POINTER TO STRING;

Replay : POINTER TO STRING;

Replay_Max_Len : UINT;

Timeout : UINT;

SSL_Enable : BOOL;

SSL_CA_Cert : STRING(80);

SSL_Client_Cert : STRING(80);

SSL_Client_Key : STRING(80);

END_VAR

VAR_OUTPUT

End : BOOL;

Error : TCPIP_ERROR;

Body_Ptr : POINTER TO STRING;

Body_Len : UINT;

END_VAR

VAR

State : INT;

END_VAR

Function block for HTTP Get/Post request and page receiving.

Input Variables

Start

Signal for activation of function block

Header_Extra

String pointer for additional custom lines in the request header

Mode

Modalities of request according to HTTP_MODE type

Username

Username for server access (optional, 30 max characters)

Password

Password for server access (optional, 30 max characters)

Host_Name

Name of the server to which request the resource (80 max characters)

Host_Port

Port address of the server (optional, default 80)

Path

Path of requested page (80 max characters)

Page 127: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

126

Query

String pointer for the parameters sending (10000 max characters)

Replay

String pointer for the replay (Header + Body)

Replay_Max_Len

Maximum number of characters to be received

Timeout

Maximum wait timeout (ms, default 5000)

SSL_Enable

SSL secure connection enable

SSL_CA_Cert

SSL CA certificate file path (80 max characters)

SSL_Client_Cert

SSL client certificate file path (80 max characters)

SSL_Client_Key

SSL client private/public keys file path (80 max characters)

Output Variables

End

End of requested operation

Error

Result of the execution (0=OK, 0 error code)

Body_Ptr

String pointer to the Body part inside replay

Body_Len

Number of characters of Body part (after Chunked decode)

Internal Variables

State

Current status of the state graph of the function block

Comments

This function block allows to send a request as HTTP client to a web server using Get or Post method.

The function block is realized with a state graph combined with a dedicated task, internal to the Run Time System. This allows the

insertion of the block in the POU without increasing the scan time of other parts of the program even lower priority.

The Header_Extra parameter adds custom lines (separate by $R$L characters) in the request header. The Mode parameter

configures Get or Post method and the HTTP protocol version (1.0 or 1.1).

The Username and Password parameters are optional and can be used to send the access permissions to the web server.

Host_Name and Host_Port define the address and port of the web server to which to send the request. The server name can be

expressed in numerical form xxx.xxx.xxx.xxx or by the domain name. In this case the IP address is resolved by the internal DNS

client.

The Path parameter must contain the path of the requested web page starting from the root of the web server (for example

/mypage.php).

Page 128: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

127

Query parameter is the pointer to the string containing any parameters (eg par1=val1&par2=val2) to be added (with ? character) to

the URL with the Get method, or the string used as a Body in the request with Post method.

The Replay parameter is the pointer to the string in which the full (Header + Body) response of the web server is saved and the

Body_Ptr output value is a pointer forced to the Body part. The Replay_Max_Len maximum size allows to limit the number of

characters inserted in the replay string.

The Timeout defines the maximum wait for the connection or response.

To connect to a secure server (https) SSL_Enable parameter must be TRUE and the certificate file path must be specified into

SSL_CA_Cert parameter. If it's also required the client local certificate verification, the SSL_Client_Cert and SSL_Client_Key fields

must be specified with the local files (a null value of the fileds disables client verification).

The sequence of sending request and receiving response begins after the Start signal. At the end of the operation, the End output

signal is activated and the Error output value reports the status.

In the case of HTTP 1.0, the end of the answer is identified by automatic disconnection of the server or by the receipt of the "Content-

Length: nnn" line in the header. Furthermore, for the HTTP 1.1 protocol also a chunked (divided into blocks of pre-indicated length)

content of Body is handled. In this case the Body part is automatically decoded by the function block.

The Body_Len output value is the length of the Body part.

The function block returns the operation result with Error output variable as follows:

0 : success

-1...-4: DNS client error

1/2/4/8/16/32/64/65: SSL functions error

100: Parameter of function block not valid

101: TCP/IP receive timeout

201...265: TCP/IP functions error

1000: Bad parameters into replay

1001: Status Code not valid into HTTP replay

1100...1599: HTTP Status Code (added with offset=1000)

Related Topics

HTTP_MODE

TCPIP_ERROR

Page 129: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

128

1.12.7 HTTP_Get

FUNCTION HTTP_Get : INT

VAR_INPUT

Request : STRING;

Result : STRING;

Result_Max_Len : INT;

DNS : STRING;

END_VAR

Sends HTTP GET request and receive the result page.

Return Value

0 : success

-1...-4: DNS client error

1/2/4/8/16/32/64/65: SSL functions error

100: TCP/IP receive timeout

201...265: TCP/IP functions error

Input Parameters

Request

URL of the requested resource

Result

String to receive the response (max 10000 characters)

Result_Max_Len

Max number of characters to receive

DNS

Specific DNS server address (xxx.xxx.xxx.xxx)

Comments

This function sends a request to a web server using an URL with GET method and returns all the string (including header) of the

page. The Request parameter is the string containing the request with the form:

Username:Password@Host:Port/Path?Query Username:Password@ send optional authorization fields Host address of the server that has the resource :Port select a port other than the default (80) /Path full path to the server resource ?Query parameters to send: ?par1=xxx&par2=yyy&par3=zzz...

The Result parameter is the string in which to insert the response from the server. This response contains a header, typical of HTTP,

followed by the actual output of the server (body). The header and the body are separated by a blank line, which can be searched as

the beginning of the body part. The Result_Max_Len parameter is the maximum number of characters to receive in the response

string.

The DNS parameter allows the specification of a different DNS server which has priority over the default setting into CHIP.INI

configuration file.

The SSL connections require an enabling and configuration using the file CHIP.INI (refer to the administration pages).

Example

Err_Code := HTTP_Get('www.mysite.com/page.php?par1=123&par2=456', Result, 500, '');

Page 130: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

129

Related Topics

HTTP_Post

Page 131: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

130

1.12.8 HTTP_Post

FUNCTION HTTP_Post : INT

VAR_INPUT

Request : STRING;

Query : STRING;

Result : STRING;

Result_Max_Len : INT;

DNS : STRING;

END_VAR

Sends HTTP POST request and receive the result page.

Return Value

0 : success

-1...-4: DNS client error

1/2/4/8/16/32/64/65: SSL functions error

100: TCP/IP receive timeout

201...265: TCP/IP functions error

Input Parameters

Request

URL of the requested resource

Query

String with the parameters list (max 5000 characters)

Result

String to receive the response (max 10000 characters)

Result_Max_Len

Max number of characters to receive

DNS

Specific DNS server address (xxx.xxx.xxx.xxx)

Comments

This function sends a request to a web server using an URL with POST method and returns all the string (including header) of the

page. The Request parameter is the string containing the request with the form:

Username:Password@Host:Port/Path Username:Password@ send optional authorization fields Host address of the server that has the resource :Port select a port other than the default (80) /Path full path to the server resource

Query parameter is the string containing the parameters:

Query parameters to send: par1=xxx&par2=yyy&par3=zzz...

The Result parameter is the string in which to insert the response from the server. This response contains a header, typical of HTTP,

followed by the actual output of the server (body). The header and the body are separated by a blank line, which can be searched as

the beginning of the body part. The Result_Max_Len parameter is the maximum number of characters to receive in the response

string.

Page 132: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

131

The DNS parameter allows the specification of a different DNS server which has priority over the default setting into CHIP.INI

configuration file.

The SSL connections require an enabling and configuration using the file CHIP.INI (refer to the administration pages).

Example

Err_Code := HTTP_Post('www.mysite.com/page.php', 'par1=123&par2=456', Result, 500, '');

Related Topics

HTTP_Get

Page 133: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

132

1.12.9 SendMail

FUNCTION SendMail : BOOL

VAR_INPUT

Local_IP : STRING;

From_Address : STRING;

From_Alias : STRING;

Server_Add : STRING;

Username : STRING;

Password : STRING;

To_Address : STRING;

Subject : STRING;

Attached_File : STRING;

Text : STRING;

END_VAR

Sends an E-mail by the specified SMTP server.

Return Value

TRUE : success

FALSE : error

Input Parameters

Local_IP

IP address of sender into Local Area Network (not necessary)

From_Address

E-mail address of sender

From_Alias

Alias name of sender (not necessary)

Server_Add

Address of SMTP server (E-mail account)

Username

Username for SMTP server login (E-mail account)

Password

Password for SMTP server login (E-mail account)

To_Address

Address of the recipient of E-mail

Subject

Description of the E-mail subject (not necessary)

Attached_File

Path/name of attached file (not necessary)

Text

Text of the E-mail (not necessary)

Comments

Page 134: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

133

This function connects to a SMTP server and sends an E-mail to a destination address.

The first six parameters are normally fixed because they define the sender informations and the specific E-mail account on a SMTP

server. The data of the account are furnished by the provider of E-mail service.

Local_IP, From_Address and From_Alias parameters identify the sender, that is the IEC system calling this function to send mail. For

the purposes of sending mail are not necessary but however their definition allows the recipient to know the origin of the message.

Server_Add, Username and Password parameters are instead mandatory because they must match those of the E-mail account that

is activated by a SMTP service provider.

The Server_Add parameter can be specified in the format xxx.xxx.xxx.xxx or by the server name. In this case the DNS client is used

to resolve the IP address of the name.

The communication with the server use the standard port 25. A different port can be specified in the Server_Add parameter adding

the port number (after the separator character ':').

The SSL connections require an enabling and configuration using the file CHIP.INI (refer to the administration pages).

The E-mail address of the recipient is set into To_Address parameter.

The Subject parameter is a string that describe the object of the E-mail.

Any attached file to the E-mail can be indicated by the File parameter. The attached file must reside on a accessible disk of the

system.

The text of E-mail must be passed using the Text string. The use special of characters (as $N for new line and $L for line feed) are

allowed.

Example

Result := SendMail('192.168.1.101', '[email protected]', 'MyTarget', '213.165.64.45', 'username', 'password', '[email protected]', 'E-mail test', 'A:\PLC_PRG\Attached.txt', 'This is the E-mail text' );

Page 135: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

134

1.12.10 SendPing

FUNCTION BLOCK SendPing

VAR_INPUT

Start : BOOL;

IP_Address : STRING(80);

Interval : INT;

Data_Length : INT;

END_VAR

VAR_OUTPUT

Ping_Ok : BOOL;

Ping_Err : BOOL;

Send_Count : UDINT;

Recv_Count : UDINT;

Max_RTT : UDINT;

Min_RTT : UDINT;

Last_RTT : UDINT;

END_VAR

VAR

State : INT;

END_VAR

Function block for running the Ping on a network device.

Input Variables

Start

Activation signal. If TRUE starts the continuos ping on IP_Address

IP_Address

IP address of the device on the network on which execute the ping

Interval

Interval time (seconds) between consecutive pings. Default to 3.

Data_Length

Length of the data packet (max 2080). Default to 32.

Output Variables

Ping_Ok

Response of the last ping received

Ping_Err

Response of the last ping not received

Send_Count

Number of packets transmitted

Recv_Count

Number of packets received

Max_RTT

Maximum Round Trip Time (ms)

Min_RTT

Page 136: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

135

Minimum Round Trip Time (ms)

Last_RTT

Round Trip Time (ms) in the last ping

Internal Variables

State

Current status of the state graph of the function block

Comments

This function block allows the checking of the connection quality with a specific network address using the Ping function.

The address to be tested must be entered in IP_Address parameter in numerical form (xxx.xxx.xxx.xxx) or using the domain name. In

this case, the domain name is resolved through the internal DNS client.

After starting with the Start input the test is executed with periodic transmission to the remote device of a data packet whose length is

defined by Data_Length. The tested device will respond to Ping sending its response data packet to be received and analyzed by the

function block.

The two output parameters, Send_Count and Recv_Count, record the number of packets transmitted and accordingly received.

The Interval parameter specifies the time in seconds between each test and the next. It is advisable to not run the function block for

long time or with a very short interval time to not overload the network.

The function block verifies at each test the Send_Count and Recv_Count values and, in the case of an increase of both, the Ping_Ok

output is activated. In the case that the number of receptions is not incremented at each test the Ping_Err output is activated.

The function block also returns the values of the RTT (Round Trip Time) as statistical of connection response time. The values

Max_RTT, Min_RTT and Last_RTT indicate the maximum, minimum and the value of last test.

Page 137: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

136

1.12.11 SMTP_Client

FUNCTION BLOCK SMTP_Client

VAR_INPUT

Start : BOOL;

From_Address : STRING(50);

From_Alias : STRING(50);

Server_Name : STRING(80);

Server_Port : UINT := 25;

Username : STRING(30);

Password : STRING(30);

To_Address : POINTER TO STRING(50);

Subject : POINTER TO STRING(80);

Attached_File : POINTER TO STRING(80);

Text : POINTER TO STRING(10000);

Timeout : UINT := 10000;

SSL_Enable : BOOL;

SSL_Cacert: STRING(80);

END_VAR

VAR_OUTPUT

End : BOOL;

Error : TCPIP_ERROR;

END_VAR

VAR

State : INT;

END_VAR

Function block for sending an E-mail with an optional attached file.

Input Variables

Start

Signal for activation of function block

From_Address

Sender E-mail address (not mandatory, max 50 characters)

From_Alias

Sender alias name (not mandatory, max 50 characters)

Server_Name

Name of the E-mail server (max 80 characters)

Server_Port

Port address of the E-mail server (optional, default 25)

Username

Username to log in the SMTP server account (maximum 30 characters)

Password

Password to log in the SMTP server account (maximum 30 characters)

To_Address

E-mail address of recipient

Subject

Description of subject of E-mail

Page 138: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

137

Attached_File

name of the file attached to E-mail

Text

Text of E-mail

Timeout

Maximum wait timeout (ms, default 10000)

SSL_Enable

SSL secure connection enable

SSL_Cacert

SSL certificate file path (80 max characters)

Output Variables

End

End of requested operation

Error

Result of the execution (0=OK, 0 error code)

Internal Variables

State

Current status of the state graph of the function block

Comments

This function block allows to send an E-mail as SMTP client with optional attached file.

The function block is realized with a state graph combined with a dedicated task, internal to the Run Time System. This allows the

insertion of the block in the POU without increasing the scan time of other parts of the program even lower priority.

From_Address and From_Alias parameters identify the sender, that is the IEC system calling this function block to send mail. For the

purposes of sending mail are not necessary but however their definition allows the recipient to know the origin of the message.

Server_Name, Server_Port, Username and Password parameters are instead mandatory because they must match those of the E-

mail account that is activated by a SMTP service provider. The server name can be expressed in numerical form xxx.xxx.xxx.xxx or by

the domain name. In this case the IP address is resolved by the internal DNS client.

The Server_Port parameter defaults to 25 but for SSL connections should normally be set to 465. To connect to a secure server

SSL_Enable parameter must be TRUE and the certificate file path must be specified into SSL_Cacert parameter. Included is provided

a file with path 'A:\SSL_CERT\ EquifaxSecureCA.pem' which also provides access to the 'smtp.gmail.com' server used by gmail

accounts.

The Timeout defines the maximum wait for the connection or response.

The E-mail address of the recipient is set into To_Address parameter.

The Subject parameter is a string that describe the object of the E-mail.

Any attached file to the E-mail can be indicated by the Attached_File parameter. The attached file must reside on a accessible disk of

the system.

The text of E-mail must be passed using the Text string. The use special of characters (as $N for new line and $L for line feed) are

allowed.

The request to the server begins after the Start signal. At the end of the operation, the End output signal is activated and the Error

output value reports the status.

The function block returns the operation result with Error output variable as follows:

0 : success

-1...-4: DNS client error

1/2/4/8/16/32/64/65: SSL functions error

101: TCP/IP receive timeout

102: TCP/IP receive overflow

201...265: TCP/IP functions error

2000: Received unexpected intermedie line

Page 139: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

138

2001: Received unexpected last line

2100: Text of E-mail too large

2101: No username/password defined

2102: Unknown authorization request from server

2103: Bad CRAM-MD5 received from server

2104: Attached file not found

2105: Error while reading attached file

2106: Error while sending attached file

Related Topics

TCPIP_ERROR

Page 140: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

139

1.12.12 SNTP_DateTime

FUNCTION SNTP_DateTime : BOOL

VAR_INPUT

Server_IP : STRING;

TimeZone : INT;

Daylight_Save : BYTE;

END_VAR

Synchronizes Real Time Clock with the specified NTP server.

Return Value

TRUE : success

FALSE : error

Input Parameters

Server_IP

IP address of NTP server

TimeZone

Geographical zone offset (UTC+n)

Daylight_Save

Daylight saving enable (+1h)

Comments

This function connects to a NTP server and request the reference date and time.

The IP address of NTP server can be specifies in the format xxx.xxx.xxx.xxx or with the string of address name (in this case the

internal DNS resolver is used).

TimeZone parameter identifies the geographical zone (for example +1 for Rome). This offset is added to the UTC (Coordinated

Universal Time) returned by NTP server.

Daylight_Save enable the sum of one hour to take account of daylight saving. This enabling is diversified for every country so its

management request the knowledge of the specific situation. With the value 0 of the parameter does not add one hour (winter), while

with the value 1 is added one hour (summer). The values above 1 encoding zones for the automatic calculation of daylight saving.

Currently it is implemented the management of value 2 relative to Europe.

The resultant value of date and time is finally forced into the Real Time Clock device of PLC.

NOTE: by enabling the automatic NTP synchronization with the appropriate configuration parameters of CHIP.INI file (see NTP

section of the configuration Web interface), a single NTP synchronization is executed every time the PLC power supply is started.

Successive NTP synchronizations with CHIP.INI default parameters can be then triggered inside IEC program calling the function with

null input values: SNTP_DateTime('', 0, 0).

Example

Result := SNTP_DateTime('62.206.250.163', +1, TRUE);

Page 141: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

140

1.13 The MySQL library (MySQL_Lib.lib)

This library offers the functions for the management of the MySQL databases.

MySQL is one of the world's most used database and its data access is based on SQL (Structured Query Language) protocol. A detailed

documentation can be found at the following link http://www.mysql.com.

Most of Web hosting provider offers a service for the MySQL database. In this way, you can access directly to the database using various tools

provided in the control panel of the service.

There are also several tools program, running on your PC, to access and manage a remote MySQL database. One of these is

http://www.heidisql.com which is a powerful and free tool to create and interact with a local or remote database.

In addition there are various tools for the direct installation of a MySQL database on your server or PC as

href="http://www.apachefriends.org/en/xampp.html or http://www.wampserver.com/en/download.php. These tools, installed on a local server, allow

both the running of PHP scripts and the MySQL database management, as it happens with the external Web hosting services.

The MySQL library consists of CoDeSys functions that access, using the HTTP client, to a PHP server for the execution of a script as interface

with MySQL. For this you need to pre-install the MySQL folder containing the PHP code on a server that can also be the same that runs the

MySQL database. The PHP code, triggered by the library functions, performs a specific queries on the database and returns data in response.

Later, other library functions can access to the data received by the query.

Here is a list of all the functions this library offers:

MySQL_Connect_Set

MySQL_Data_Seek

MySQL_Database_Set

MySQL_Fetch_Row

MySQL_Field_Len

MySQL_Field_Name

MySQL_Num_Fields

MySQL_Num_Rows

MySQL_Query

MySQL_Result

Page 142: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

141

1.13.1 MySQL_Connect_Set

FUNCTION MySQL_Connect_Set : BOOL

VAR_INPUT

Php_Url : STRING;

Server : STRING;

Username : STRING;

Password : STRING;

END_VAR

Sets the parameters for connecting to MySQL database.

Return Value

Always TRUE

Input Parameters

Php_Url

URL path of the PHP interface page (max 200 characters)

Server

Address of the server for MySQL database access (max 200 characters)

Username

Username for database access (max 80 characters)

Password

Password for database access (max 80 characters)

Comments

This function sets the connection parameters to be used for all subsequent operations on the MySQL database.

The database management is done through the HTTP client access to the PHP page as interface with the MySQL server. The

mysql_query.php file must be installed on a PHP server, set by the Php_Url parameter, not necessarily the same server used for

MySQL database.

The Server parameter sets the address of the database host and is usually "localhost" if the same server running the PHP interface

code.

The Username and Password parameters must match the authorization for the user enabled to perform operations on the MySQL

database.

Related Topics

MySQL_Database_Set

Page 143: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

142

1.13.2 MySQL_Data_Seek

FUNCTION MySQL_Data_Seek : BOOL

VAR_INPUT

Row : UINT;

END_VAR

Forces the row pointer for result set reading.

Return Value

TRUE : success

FALSE : error

Input Parameters

Row

Position of the next line read from the result set

Comments

The function sets the pointer position of the next row of result set to be read with the MySQL_Fetch_Row function.

After a query, the pointer is positioned to value 0 corresponding to read the first row of the result set. Each sequential row read

increment the pointer by one position. With this function you can reposition the cursor on a row between 0 and Num_Rows-1 where

Num_Rows is the value returned by the MySQL_Num_Rows.

The function returns 1 if successful and returns 0 if the location requested is not available.

Related Topics

MySQL_Fetch_Row

Page 144: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

143

1.13.3 MySQL_Database_Set

FUNCTION MySQL_Database_Set : BOOL

VAR_INPUT

Database : STRING;

END_VAR

Selects the MySQL database currently in use.

Return Value

Always TRUE

Input Parameters

Database

Name of the current database to use (max 80 characters)

Comments

This function sets the name of the MySQL database to be used for all subsequent management functions.

The management is done by running the PHP script that initially make the MySQL connection using the parameters set by the

MySQL_Connect_Set function. Then the database selection is made using the name set by the MySQL_Database_Set function. After

running the script interface and returning the response, the database connection is closed.

Related Topics

MySQL_Connect_Set

Page 145: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

144

1.13.4 MySQL_Fetch_Row

FUNCTION MySQL_Fetch_Row : STRING

VAR_INPUT

Row : STRING;

END_VAR

Extracts a row from the query result set.

Return Value

The same string pointer passed as parameter

Input Parameters

Row

Pointer of string where to copy the row readed

Comments

The database queries such as SELECT, SHOW, DESCRIBE, EXPLAIN returns a result set consisting of whole rows (table records)

that satisfy the condition of the query. The query function saves the entire result set into a memory buffer from where you can

sequentially extract individual rows by MySQL_Fetch_Row function calls.

Each fetched row is copied into the string pointed by the Row parameter passed to the function and contains all the columns (fields) of

the record separated by semicolons (plus space). All fields of string type are delimited by single quotes (apostrophes).

If the row is not available returns the empty string.

Related Topics

MySQL_Data_Seek

Page 146: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

145

1.13.5 MySQL_Field_Len

FUNCTION MySQL_Field_Len : UINT

VAR_INPUT

Field : UINT;

END_VAR

Reads the length of a field of the database table.

Return Value

Length of the field in the table

Input Parameters

Field

Number of field for which read the length

Comments

The function allows to know the length of a specific field of the table following the execution of a query that returns a result set.

The length is determined at creation of the field in the table and also defines the memory used to store values.

Related Topics

MySQL_Num_Fields

MySQL_Field_Name

Page 147: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

146

1.13.6 MySQL_Field_Name

FUNCTION MySQL_Field_Name : STRING

VAR_INPUT

Name : STRING;

Field : UINT;

END_VAR

Reads the name of a database table field.

Return Value

The same string pointer passed as parameter

Input Parameters

Name

Pointer of string where to copy the name readed

Field

Number of field for which read the name

Comments

This feature allows you to read the name associated with one of the fields (columns) of the table following the execution of a query

that returns a result set.

The parameter Field indicates the position of the column between 0 and Num_Fields-1 where Num_Fields is the value returned by

MySQL_Num_Fields.

The field name is copied to the string pointed by the Name parameter passed to the function.

If the name is not available returns the empty string.

Related Topics

MySQL_Num_Fields

MySQL_Field_Len

Page 148: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

147

1.13.7 MySQL_Num_Fields

FUNCTION MySQL_Num_Fields : UINT

Reads the current number of fields after a query execution.

Return Value

Number of fields in the table related to the query

Input Parameters

None

Comments

This function allows you to read the number of fields (columns) available in the table following the execution of a query that returns a

result set.

Related Topics

MySQL_Num_Rows

Page 149: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

148

1.13.8 MySQL_Num_Rows

FUNCTION MySQL_Num_Rows : UDINT

Reads the current number of rows after a query execution.

Return Value

Number of rows in the table related to the query

Input Parameters

None

Comments

This feature allows you to read the number of rows in the table after a query execution.

For queries that return a result set the readed number of rows corresponds to many records in the table have been affected by the

query. For example, after a "DELETE FROM table WHERE condition" returns the number of deleted rows in the table according to the

WHERE condition.

For query functions that return a result set, the number of rows resulting from the function corresponds to the number of records

readed from the table according to a certain condition and that can be readed with subsequent MySQL_Fetch_Row function calls.

Related Topics

MySQL_Num_Fields

Page 150: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

149

1.13.9 MySQL_Query

FUNCTION MySQL_Query : STRING

VAR_INPUT

Query : STRING;

END_VAR

Sends a query to the MySQL database.

Return Value

0 : success

-1...-4: DNS client error

201...265: TCP/IP functions error

1/2/4/8/16: SSL functions error

1001: Server parameter is not defined

1002: Username parameter is not defined

1003: Password parameter is not defined

1004: Database parameter is not defined

1005: Query parameter is not defined

2001: MySQL connection error

2002: Error selecting database

2003: Error executing query

3001: no tag received for the error code

3002: no tag received for number of rows (records)

3003: no tag received for result set available

3004: no tag received for number of fields (columns)

3005: no tag received for field names

3006: no tag received for field lengths

3007: no tag received for the result set row

Input Parameters

Query

The query string to execute on the MySQL database

Comments

This function sends a query to the MySQL database that is currently selected by MySQL_Database_Set.

To prepare the query string, passed directly to the database server, refer to the official MySQL documentation.

The query INSERT, UPDATE, DELETE, CREATE, ALTER, DROP, do not return a result set (a set of data readed from the database).

Queries such as SELECT, SHOW, DESCRIBE, EXPLAIN instead save the result set into a buffer from which are then extracted

values of the table rows with appropriate fetch functions.

The function returns 0 if it executes without error, otherwise returns the error code. The error code can be any of those provided by

the function HTTP_Post used to access the interface PHP page, or a specific error code of PHP script execution.

Related Topics

MySQL_Connect_Set

MySQL_Database_Set

Page 151: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

150

1.13.10 MySQL_Result

FUNCTION MySQL_Result : STRING

VAR_INPUT

Cell : STRING;

Row : UINT;

Field : UINT;

END_VAR

Extracts a single cell of the query result set.

Return Value

The same string pointer passed as parameter

Input Parameters

Cell

Pointer of string where to copy the cell readed

Row

Row number of the cell to read

Field

Field number of the cell to read

Comments

The database queries such as SELECT, SHOW, DESCRIBE, EXPLAIN returns a result set consisting of whole rows (table records)

that satisfy the condition of the query. The query function saves the entire result set into a memory buffer from which can then extract

the value of a single cell with MySQL_Result function, directly specifying the line and column number using the Row and Field

parameters.

The value of the cell is returned as a string to the position defined by the pointer passed as a Cell parameter. Furthermore, if the

contents of the cell is a variable of string type, the result is delimited by single quotes (apostrophe) as it does for MySQL_Fetch_Row

function.

This function accesses randomly, and not sequentially as MySQL_Fetch_Row, to a single cell of the table (a cross between the row

and column of the result set). However, to read more cells in a row you should use the MySQL_Fetch_Row that is faster than

MySQL_Result.

If the cell is not available returns the empty string.

Related Topics

MySQL_Num_Rows

MySQL_Num_Fields

Page 152: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

151

1.14 The RS485/Serial library (rs485.lib)

This library offers extended functionality for serial communication via the RS485 protocol. Especially for controlling an RS485 transceiver,

because here the transmitter may only be active while data is actually sent.

The available port numbers are enumerated in RS485_PORTS.

This library offers the following functions and data types:

TYPE RS485_BREAK

TYPE RS485_FLOWCTRL

TYPE RS485_MODE

TYPE RS485_PARITY

TYPE RS485_PORTS

Rs485ComClose

Rs485ComOpen

Rs485FlushOutput

Rs485GetStatus

Rs485IsByteAvailable

Rs485PurgeInput

Rs485PurgeOutput

Rs485ReceiveBlock

Rs485ReceiveByte

Rs485SendBlock

Rs485SendBreak

Rs485SendByte

Rs485SetFlowcontrol

Rs485SetMode

Page 153: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

152

1.14.1 TYPE RS485_BREAK

TYPE RS485_BREAK

TYPE RS485_BREAK : ( RS485_BREAK_LONG := 1, RS485_BREAK_SHORT := 2, RS485_BREAK_EXTRALONG := 3 ); END_TYPE

This type enumerates the desired length of a break pulse.

Member

RS485_BREAK_LONG := 1

long break (Duration: > 1 character)

RS485_BREAK_SHORT := 2

short break (Duration: > 2 characters)

RS485_BREAK_EXTRALONG := 3

extra long break (Duration: > 3 characters)

Page 154: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

153

1.14.2 TYPE RS485_FLOWCTRL

TYPE RS485_FLOWCTRL

TYPE RS485_FLOWCTRL : ( RS485_FLOWCTRL_OFF := 0, RS485_FLOWCTRL_XONXOFF_SEND := 1, RS485_FLOWCTRL_RTSCTS := 2, RS485_FLOWCTRL_XONXOFF_RECV := 8, RS485_FLOWCTRL_XONXOFF_SEND_RECV := 9 ); END_TYPE

This type enumerates the desired method of flow control.

Member

RS485_FLOWCTRL_OFF := 0

no flow control

RS485_FLOWCTRL_XONXOFF_SEND := 1

XONXOFF on transmit (watch for XOFF while sending)

RS485_FLOWCTRL_RTSCTS := 2

CTS on transmit, RTS on receive

RS485_FLOWCTRL_XONXOFF_RECV := 8

XONXOFF on receive (send XOFF when buffer nearly full)

RS485_FLOWCTRL_XONXOFF_SEND_RECV := 9

XONXOFF used on both Tx and Rx

Page 155: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

154

1.14.3 TYPE RS485_MODE

TYPE RS485_MODE

TYPE RS485_MODE : ( RS485_MODE_LOWACTIVE := 0, RS485_MODE_HIGHACTIVE := 1, RS485_DISABLE := 2 ); END_TYPE

This type enumerates the desired method.

Member

RS485_MODE_LOWACTIVE := 0

Tx Enable low active

RS485_MODE_HIGHACTIVE := 1

Tx Enable high active

RS485_DISABLE := 2

Disable RS485 Mode

NOTE: normally this parameter must be set to RS485_MODE_HIGHACTIVE.

Page 156: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

155

1.14.4 TYPE RS485_PARITY

TYPE RS485_PARITY

TYPE RS485_PARITY : ( RS485_PARITY_NO := 0, RS485_PARITY_ODD := 1, RS485_PARITY_EVEN := 2, RS485_PARITY_MARK := 3, RS485_PARITY_SPACE := 4 ); END_TYPE

This type enumerates the desired parity setting of a serial port.

Member

RS485_PARITY_NO := 0

no parity

RS485_PARITY_ODD := 1

odd parity

RS485_PARITY_EVEN := 2

even parity

RS485_PARITY_MARK := 3

mark parity

RS485_PARITY_SPACE := 4

space parity

Page 157: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

156

1.14.5 TYPE RS485_PORTS

TYPE RS485_PORTS

TYPE RS485_PORTS : ( RS485_COM1 := 1, RS485_COM2 := 2, RS485_COM3 := 3, RS485_COM4 := 4, RS485_COM5 := 5, RS485_COM6 := 6, RS485_COM7 := 7, RS485_COM8 := 8 ); END_TYPE

This type enumerates the desired serial port.

Member

RS485_COM1 := 1

Uart0

RS485_COM2 := 2

Uart1

RS485_COM3 := 3

Uart2

RS485_COM4 := 4

Uart3

RS485_COM5 := 5

Virtual Serial Interface via USB

RS485_COM6 := 6

Virtual Serial Interface via USB

RS485_COM7 := 7

Virtual Serial Interface via USB

RS485_COM8 := 8

Virtual Serial Interface via USB

Page 158: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

157

1.14.6 Rs485ComClose

FUNCTION Rs485ComClose : BOOL

VAR_INPUT

handle : DWORD;

END_VAR

Closes a serial communications port.

Return Value

TRUE : success

FALSE : error

Input Parameters

handle

Port handle returned by Rs485ComOpen

Comments

Use this function to close a port that is no longer used.

Related Topics

Rs485ComOpen

Page 159: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

158

1.14.7 Rs485ComOpen

FUNCTION Rs485ComOpen : DWORD

VAR_INPUT

port : RS485_PORTS;

baud : DINT;

parity : RS485_PARITY;

wordlen : INT;

stopbits : INT;

END_VAR

Opens a serial port.

Return Value

Returns 16#FFFFFFFF when called with invalid parameters.

Otherwise a port handle is returned. This handle has to be used in further calls to this interface.

Input Parameters

port

Number of desired port (enumeration type)

baud

Baud rate (110..115200)

parity

Parity (enumeration type)

wordlen

Data length (7 or 8 bits)

stopbits

Number of stop bits (1 or 2)

Related Topics

Rs485ComClose

Rs485SetFlowcontrol

Page 160: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

159

1.14.8 Rs485FlushOutput

FUNCTION Rs485FlushOutput : BOOL

VAR_INPUT

dwHandle : DWORD;

END_VAR

Waits until all data from the output buffer has been sent.

Return Value

TRUE : success

FALSE : error

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

Comments

Be careful when using this function. The controller will wait until the function is finished. This might take a while if the baud rate is low

and there are many characters in the buffer to send.

Related Topics

Rs485PurgeOutput

Rs485PurgeInput

Page 161: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

160

1.14.9 Rs485GetStatus

FUNCTION Rs485GetStatus : INT

VAR_INPUT

handle : DWORD;

END_VAR

Returns the status of a serial port.

Return Value

Returns a status code (bit field)

Input Parameters

handle

Port handle returned by Rs485ComOpen

Comments

The status bits have the following meaning:

bit 6: RS485_OUTPUT_BUFFER_EMPTY (tx buffer is empty) bit 5: RS485_OUTPUT_NOT_FULL (tx buffer is not full) bit 4: RS485_LINE_BREAK (line break detected) bit 3: RS485_FRAMING_ERROR (framing error detected) bit 2: RS485_PARITY_ERROR (parity error detected) bit 1: RS485_OVERRUN_ERROR (overrun occurred on receiver) bit 0: RS485_DATA_AVAILABLE (data is available in rx buffer)

Related Topics

Rs485SetFlowcontrol

Rs485SendBreak

Rs485ComOpen

Page 162: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

161

1.14.10 Rs485IsByteAvailable

FUNCTION Rs485IsByteAvailable : INT

VAR_INPUT

dwHandle : DWORD;

END_VAR

Peek if received data is available, without removing the data from the internal receive buffer.

Return Value

Returns the received byte or -1 in case of an invalid parameter or no data available

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

Comments

The only difference to Rs485ReceiveByte is that with Rs485IsByteAvailable the received byte is not removed from the receive buffer.

Related Topics

Rs485ReceiveByte

Page 163: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

162

1.14.11 Rs485PurgeInput

FUNCTION Rs485PurgeInput : BOOL

VAR_INPUT

dwHandle : DWORD;

END_VAR

Discards the contents of the serial receive buffer.

Return Value

TRUE : success

FALSE : error

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

Comments

All data in the serial receive buffer will be discarded and not be read.

Related Topics

Rs485FlushOutput

Rs485PurgeOutput

Page 164: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

163

1.14.12 Rs485PurgeOutput

FUNCTION Rs485PurgeOutput : BOOL

VAR_INPUT

dwHandle : DWORD;

END_VAR

Discards the contents of the serial transmit buffer.

Return Value

TRUE : success

FALSE : error

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

Comments

All data in the serial transmit buffer will be discarded and not be sent.

Related Topics

Rs485FlushOutput

Rs485PurgeInput

Page 165: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

164

1.14.13 Rs485ReceiveBlock

FUNCTION Rs485ReceiveBlock : UINT

VAR_INPUT

dwHandle : DWORD;

pBuffer : POINTER to BYTE;

count : UINT;

END_VAR

Receives a block of data from a serial port. Returns immediately if no data has been received.

Return Value

Returns the number of bytes transferred to the buffer

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

pBuffer

Pointer to buffer where to store received data

count

Maximum number of bytes to put into the buffer

Related Topics

Rs485ReceiveByte

Rs485SendBlock

Rs485SendByte

Page 166: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

165

1.14.14 Rs485ReceiveByte

FUNCTION Rs485ReceiveByte : INT

VAR_INPUT

dwHandle : DWORD;

END_VAR

Receives a byte of data from a serial port. Returns immediately if no data has been received.

Return Value

Returns the received byte or -1 in case of an invalid parameter or no data available

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

Related Topics

Rs485SendByte

Rs485SendBlock

Rs485ReceiveBlock

Page 167: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

166

1.14.15 Rs485SendBlock

FUNCTION Rs485SendBlock : UINT

VAR_INPUT

dwHandle : DWORD;

pBuffer : POINTER to BYTE;

count : UINT;

END_VAR

Sends a block of data via a serial port.

Return Value

Returns the number of bytes sent

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

pBuffer

Pointer to data to send (can be obtained using the ADR() function)

count

Number of bytes to send

Related Topics

Rs485SendByte

Rs485ReceiveByte

Rs485ReceiveByte

Page 168: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

167

1.14.16 Rs485SendBreak

FUNCTION Rs485SendBreak : BOOL

VAR_INPUT

dwHandle : DWORD;

length : RS485_BREAK;

END_VAR

Sends a break signal on a serial port.

Return Value

TRUE : success

FALSE : error

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

length

Length of the break pulse (enumeration type)

Comments

A short break is a continuous Low on the TXD output for a duration of more than one frame transmission time M, where: M = startbit + data bits (+ parity bit) + stop bit.

A long break is a continuous Low on the TXD output for a duration of more than two frame transmission times plus the transmission

time for three additional bits (2M+3).

An extra long break is a continuous Low on the TXD output for a duration of more than three frame transmission times.

Related Topics

Rs485GetStatus

Page 169: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

168

1.14.17 Rs485SendByte

FUNCTION Rs485SendByte : INT

VAR_INPUT

dwHandle : DWORD;

ch : BYTE;

END_VAR

Sends a byte of data to a serial port.

Return Value

Returns 0 if no buffer space to store character available, or 1 on success, or -1 on invalid parameter

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

ch

Character to send

Related Topics

Rs485ReceiveByte

Rs485SendBlock

Rs485ReceiveBlock

Page 170: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

169

1.14.18 Rs485SetFlowcontrol

FUNCTION Rs485SetFlowcontrol : USINT

VAR_INPUT

dwHandle : DWORD;

flowctrl : RS485_FLOWCTRL;

END_VAR

Sets the flowcontrol method of a serial port.

Return Value

TRUE : success

FALSE : error

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

flowctrl

Flowcontrol method (bit field / enumeration type)

Comments

The RS485_FLOWCTRL enumeration type is also declared in this library.

Related Topics

Rs485ComOpen

Page 171: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

170

1.14.19 Rs485SetMode

FUNCTION Rs485SetMode : BOOL

VAR_INPUT

dwHandle : DWORD;

mode : RS485_MODE;

END_VAR

Selects the operating mode of the port.

Return Value

TRUE : success

FALSE : error

Input Parameters

dwHandle

Port handle returned by Rs485ComOpen

mode

Mode (enumeration type)

Comments

This function should be the first function called before any data exchange can take place.

Related Topics

Rs485ComOpen

Page 172: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

171

1.15 The RS485/Expansion library (RS485_Lib.lib)

This library offers the functions for the management of the RS485 slave expansion.

A complete refresh of slave expansion resources is obtained using this functions into IEC program.

Here is a list of all the functions and data type this library offers:

DMX512_Tx

RS485_Init_A

RS485_Tx_Rx_A

Page 173: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

172

1.15.1 DMX512_Tx

FUNCTION DMX512_Tx : UINT

VAR_INPUT

Port : PORTS;

Offset : UINT;

Data_Ptr : DWORD;

Data_Num : UINT;

END_VAR

Executes the transmission of a DMX512 frame.

Return Value

0 : success

200 : bad parameter

201 : serial initialization error

Input Parameters

Port

Serial port number

Offset

Position of Data from the start of DMX512 frame

Data_Ptr

Pointer of Data buffer to send

Data_Num

Number of Data bytes

Comments

This function sends over RS485 port a sequence of bytes in accordance with the DMX512 protocol. The speed of communication is

250kbit/s and for synchronization is used a break of 3 characters (132us) followed by a start code (one byte of 0 value). Then the

buffer data bytes are sent in quantities up to 512.

The data is transmitted with a start bit, 8 data bits and 2 stop bits. The Offset parameter determines a transmission of data to 0, in an

amount equal to Offset-1, before sending the bytes of the data buffer. Normally this parameter is 1, since the data to be transmitted

are justified by the DMX512 address 1.

Data_Ptr parameter is the pointer to the first byte of data buffer to be transmitted.

Data_Num parameter is the number of bytes in the buffer to be transmitted.

Page 174: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

173

1.15.2 RS485_Init_A

FUNCTION RS485_Init_A : BOOL

VAR_INPUT

Port : PORTS;

Baudrate : UDINT;

Timeout : UINT;

Tx_Delay : UINT;

END_VAR

Initializes the RS485 type A expansion communication.

Return Value

Always TRUE

Input Parameters

Port

Serial port number (default to COM2=2)

Baudrate

Speed of communication (default to 115200 bits/s)

Timeout

Maximum wait for data reception (default to 2ms)

Tx_Delay

Bytes spacing during transmission (default to 0)

Comments

Use this function to initialize the RS485 type A communication with expansion slaves.

This function is not necessary in the case of communications with default parameter values.

Related Topics

RS485_Tx_Rx_A

Page 175: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

174

1.15.3 RS485_Tx_Rx_A

FUNCTION RS485_Tx_Rx_A : UINT

VAR_INPUT

Add_Cmd : BYTE;

Tx_Num : UINT;

Rx_Num : UINT;

IO_Ptr : DWORD;

Swap : USINT;

END_VAR

Executes the RS485 type A expansion communication.

Return Value

0 : success

200 : bad parameter

201 : serial initialization error

202 : slave has received a bad checksum

203 : master has received a bad checksum

204 : timeout during master reception

Input Parameters

Add_Cmd

Header byte with formatted slave address and command

Tx_Num

Number of bytes for output area

Rx_Num

Number of bytes for input area

IO_Ptr

Pointer to output/input area buffer

Swap

Swap bytes of word (2) or dword (4)

Comments

This function executes a complete sequence of RS485 type A communication with expansion slaves.

Type A communication works as follows.

The value of Add_Cmd parameter, that contains the address/command, is transmitted with the 9° bit forced to 1. If TxNum > 0 are

then transmitted TxNum bytes pointed by IO_Ptr. The checksum (XOR of the only data bytes) is finally trasmitted. At the end is

attended the 0 value to confirm the correct reception by the slave.

Else if Rx_Num > 0 is attended the reception of Rx_Num bytes plus checksum, saving the values in a temporary buffer. Verified the

checksum, the buffer is copied to the area pointed by IO_Ptr.

The Swap parameter flips the order of the bytes (from big endian to little endian and vice versa): for word values set Swap to 2 and for

dword values set Swap to 4. This is also applied for array of words or dwords.

Related Topics

RS485_Init_A

Page 176: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

175

1.16 The MODBUS library (MODBUS_Lib.lib)

This library offers the functions for the management of the slave expansions using MODBUS protocol.

A complete refresh of slave expansion resources is obtained using this functions into IEC program.

Here is a list of all the functions this library offers:

TYPE MB_RTU_PARITY

TYPE MODBUS_STATUS

MB_RTU_Deinit

MB_RTU_Init

MB_RTU_Rd_Coils

MB_RTU_Rd_Hold_Regs

MB_RTU_Rd_Input_Regs

MB_RTU_Rd_Inputs

MB_RTU_Req_Rsp

MB_RTU_Wr_Coils

MB_RTU_Wr_Hold_Regs

MB_RTU_Wr_Rd_Hold_Regs

MB_RTU_Wr_Single_Coil

MB_RTU_Wr_Single_Reg

MB_RTU_Slave

MB_TCP_Connect

MB_TCP_Disconnect

MB_TCP_Rd_Coils

MB_TCP_Rd_Hold_Regs

MB_TCP_Rd_Input_Regs

MB_TCP_Rd_Inputs

MB_TCP_Req_Rsp

MB_TCP_Wr_Coils

MB_TCP_Wr_Hold_Regs

MB_TCP_Wr_Rd_Hold_Regs

MB_TCP_Wr_Single_Coil

MB_TCP_Wr_Single_Reg

MB_TCP_Server

MB_Swap_Dword

MB_Swap_Dword2

MB_Swap_Word

Page 177: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

176

1.16.1 MB_RTU_PARITY

TYPE MB_RTU_PARITY

TYPE MB_RTU_PARITY : ( PARITY_NO := 0, PARITY_ODD := 1, PARITY_EVEN := 2, PARITY_NO_1S := 3 ); END_TYPE

This type enumerates the desired parity setting of a serial port.

Member

PARITY_NO := 0

no parity, 2 stop bits

PARITY_ODD := 1

odd parity, 1 stop bit

PARITY_EVEN := 2

even parity, 1 stop bit

PARITY_NO_1S := 3

no parity, 1 stop bit

NOTE: In the case of "No parity" the protocol specification requires the presence of two stop bits. However, for compatibility with other systems

that do not comply with this standard, is also available "No parity" mode with only one stop bit. Below is an extract of the official specific of

MODBUS RTU protocol:

Page 178: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

177

Page 179: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

178

1.16.2 MODBUS_STATUS

TYPE MODBUS_STATUS

TYPE MODBUS_STATUS : ( MODBUS_STANDBY := 0, MODBUS_ACTIVE := 100, MODBUS_ERROR := 200, MODBUS_PARAMETER_ERR := 201, MODBUS_OPEN_ERR := 202, MODBUS_OPTION_ERR := 203, MODBUS_BIND_ERR := 204, MODBUS_LISTEN_ERR := 205 ); END_TYPE

This type enumerates the current status of MODBUS slave/server service.

Member

MODBUS_STANDBY := 0

Service not activated

MODBUS_ACTIVE := 100

Service activated

MODBUS_ERROR := 200

Service stopped due to error

MODBUS_PARAMETER_ERR := 201

Service stopped: parameter not valid

MODBUS_OPEN_ERR := 202

Service stopped: error opening port (RTU) / socket (TCP)

MODBUS_OPTION_ERR := 203

Service stopped: error setting socket option

MODBUS_BIND_ERR := 204

Service stopped: error binding listen socket to local address

MODBUS_LISTEN_ERR := 205

Service stopped: error activating listen on socket

Related Topics

MB_RTU_Slave

MB_TCP_Server

Page 180: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

179

1.16.3 MB_RTU_Deinit

FUNCTION MB_RTU_Deinit : BOOL

Deinitializes the MODBUS RTU on RS485/RS232 for expansion communication.

Return Value

Always TRUE

Input Parameters

None

Comments

Use this function to deinitialize the MODBUS RTU communication over RS485/RS232 with expansion slaves.

Normally for the continuous refreshing of the slave resources, the communication is initialized only at poweron, leaving always on. So

this function is not normally used.

Related Topics

MB_RTU_Init

Page 181: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

180

1.16.4 MB_RTU_Init

FUNCTION MB_RTU_Init : UINT

VAR_INPUT

Port : PORTS;

Baudrate : UDINT;

Parity : MB_RTU_PARITY;

Rsp_Timeout : UINT;

END_VAR

Initializes the MODBUS RTU on RS485/RS232 for expansion communication.

Return Value

0 : success

128 : initialization parameter not valid

129 : inizialization error

Input Parameters

Port

Serial port number

Baudrate

Speed of communication (300-1M bits/s)

Parity

Parity select (0/1/2=NO/ODD/EVEN)

Rsp_Timeout

Maximum wait (ms) for slave response reception (for example 10)

Comments

Use this function to initialize the MODBUS RTU communication over RS485/RS232 with expansion slaves.

This function must be called before executing a MODBUS communication. Normally for the continuous refreshing of the slave

resources, the communication is initialized only at poweron, leaving always on.

Related Topics

MB_RTU_Deinit

Page 182: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

181

1.16.5 MB_RTU_Rd_Coils

FUNCTION MB_RTU_Rd_Coils : UINT

VAR_INPUT

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS RTU function code 1: Read Coils.

Return Value

0 : success

144 : Quantity parameter not valid

147 : replay with byte counter value not valid

Input Parameters

Slave_Add

Slave address (valid 1-247)

Address

Address of first bit to be read

Quantity

Number of bits to be read

Data

Pointer of data buffer for reading

Comments

The function reads the status of one or more bits of memory (Coils) from a specific slave using the MODBUS RTU protocol.

This is based on MB_RTU_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Slave_Add parameter selects the specific slave on serial bus.

Address parameter is the starting bit address to read.

Quantity parameter indicates the number of bits to be read.

Data parameter is the pointer of the buffer in which receive the values of the bits. The LSB of the first byte of the buffer contains the

addressed bit. The amount of bytes placed in the receive buffer is equal to: Data_Len = Quantity / 8, where if remainder > 0 then

Data_Len = Data_Len + 1.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_RTU_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_RTU_Wr_Coils

MB_RTU_Wr_Single_Coil

Page 183: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

182

1.16.6 MB_RTU_Rd_Hold_Regs

FUNCTION MB_RTU_Rd_Hold_Regs : UINT

VAR_INPUT

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS RTU function code 3: Read Holding Registers.

Return Value

0 : success

144 : Quantity parameter not valid

147 : replay with byte counter value not valid

Input Parameters

Slave_Add

Slave address (valid 1-247)

Address

Address of first word to be read

Quantity

Number of words to be read

Data

Pointer of data buffer for reading

Comments

The function reads the status of one or more words of memory (Holding Registers) from a specific slave using the MODBUS RTU

protocol.

This is based on MB_RTU_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Slave_Add parameter selects the specific slave on serial bus.

Address parameter is the starting word address to read.

Quantity parameter indicates the number of words to be read.

Data parameter is the pointer of the buffer in which receive the values of the words. The amount of bytes placed in the receive buffer

is equal to: Data_Len = 2 * Quantity.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_RTU_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_RTU_Wr_Hold_Regs

MB_RTU_Wr_Single_Reg

Page 184: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

183

1.16.7 MB_RTU_Rd_Input_Regs

FUNCTION MB_RTU_Rd_Input_Regs : UINT

VAR_INPUT

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS RTU function code 4: Read Input Registers.

Return Value

0 : success

144 : Quantity parameter not valid

147 : replay with byte counter value not valid

Input Parameters

Slave_Add

Slave address (valid 1-247)

Address

Address of first word to be read

Quantity

Number of words to be read

Data

Pointer of data buffer for reading

Comments

The function reads the status of one or more words of input (Input Registers) from a specific slave using the MODBUS RTU protocol.

This is based on MB_RTU_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Slave_Add parameter selects the specific slave on serial bus.

Address parameter is the starting word address to read.

Quantity parameter indicates the number of words to be read.

Data parameter is the pointer of the buffer in which receive the values of the words. The amount of bytes placed in the receive buffer

is equal to: Data_Len = 2 * Quantity.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_RTU_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_RTU_Rd_Inputs

Page 185: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

184

1.16.8 MB_RTU_Rd_Inputs

FUNCTION MB_RTU_Rd_Inputs : UINT

VAR_INPUT

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS RTU function code 2: Read Discrete Inputs.

Return Value

0 : success

144 : Quantity parameter not valid

147 : replay with byte counter value not valid

Input Parameters

Slave_Add

Slave address (valid 1-247)

Address

Address of first bit to be read

Quantity

Number of bits to be read

Data

Pointer of data buffer for reading

Comments

The function reads the status of one or more bits of input (Discrete Inputs) from a specific slave using the MODBUS RTU protocol.

This is based on MB_RTU_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Slave_Add parameter selects the specific slave on serial bus.

Address parameter is the starting bit address to read.

Quantity parameter indicates the number of bits to be read.

Data parameter is the pointer of the buffer in which receive the values of the bits. The LSB of the first byte of the buffer contains the

addressed bit. The amount of bytes placed in the receive buffer is equal to: Data_Len = Quantity / 8, where if remainder > 0 then

Data_Len = Data_Len + 1.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_RTU_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_RTU_Rd_Input_Regs

Page 186: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

185

1.16.9 MB_RTU_Req_Rsp

FUNCTION MB_RTU_Req_Rsp : UINT

VAR_INPUT

Slave_Add : BYTE;

Fun_Code : BYTE;

Req_Data : DWORD;

Req_Len : WORD;

Rsp_Data : DWORD;

Rsp_Len : WORD;

END_VAR

Executes a complete MODBUS RTU request tx and response rx on RS485/RS232 for expansion communication.

Return Value

0 : success

1 : slave has received a not valid function code

2 : slave has received a not valid object address

3 : slave has received a not valid object data

4 : non-recoverable error during execution of the slave function

5 : response to prevent a master receive timeout while slave performs a long operation

6 : slave is busy in the execution of required function

130 : timeout during master reception

131 : received from slave a bad parity

132 : received from slave a bad checksum

133 : bad slave address in replay

134 : bad function code in replay

135 : bad number of bytes transmitted

136 : bad number of bytes received

Input Parameters

Slave_Add

Slave address (valid 1-247)

Fun_Code

MODBUS function code

Req_Data

Pointer to request data buffer

Req_Len

Number of request data bytes

Rsp_Data

Pointer to response data buffer

Rsp_Len

Number of response data bytes aspected

Comments

This function execute a complete MODBUS RTU communication sequence over RS485/RS232 port with expansion slaves.

Slave_Add parameter select the specific slave on the serial bus.

Fun_Code parameter is the code of the function to execute.

Req_Data parameter is the pointer to the buffer with the data to be transmitted for the specific function code.

Req_Len parameter indicates the number of bytes in the Req_Data buffer to be transmitted to the slave.

Rsp_Data parameter is the pointer to the buffer in which receive the data of response to the function from the slave.

The Rsp_Len parameter indicates the number of data bytes expected in the Rsp_Data receive buffer as response to the specific

function code.

Page 187: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

186

The function returns 0 if performed without error, otherwise it returns the error code.

To use the MODBUS communication function refer to the technical documentation "MODBUS Application Protocol Specification"

downloadable at http://www.modbus-ida.org./tech.php.

In the following example one input word and one output word are refreshed for the slave at address 1:

PROGRAM MB_RTU VAR MB_RTU_Initialized: BOOL := FALSE; Req_Buf: ARRAY[0..10] OF BYTE; Rsp_Buf: ARRAY[0..10] OF BYTE; Input_Reg: WORD; Output_Reg: WORD; END_VAR (* Initialize MODBUS communication *) IF NOT MB_RTU_Initialized THEN MB_RTU_Init(COM2, 19200, PARITY_EVEN, 100); MB_RTU_Initialized := TRUE; END_IF (* Read one input word at address 0 from Slave 1 *) Req_Buf[0] := 0; Req_Buf[1] := 0; Req_Buf[2] := 0; Req_Buf[3] := 1; IF MB_RTU_Req_Rsp(1, 4, ADR(Req_Buf), 4, ADR(Rsp_Buf), 3) = 0 THEN Input_Reg := 256 * Rsp_Buf[1] + Rsp_Buf[2]; END_IF (* Write one output word at address 1 to Slave 1 *) Req_Buf[0] := 0; Req_Buf[1] := 1; Req_Buf[2] := Output_Reg / 256; Req_Buf[3] := Output_Reg MOD 256; MB_RTU_Req_Rsp(1, 6, ADR(Req_Buf), 4, ADR(Rsp_Buf), 4);

To read the input word is used the function code 4, followed by 4 bytes of data (two for the start address of the object and two for the

amount of words to read). The expected response consists of 3 bytes of data. The first is a input bytes count (in this case 2 because

is required 1 word) while the remaining 2 bytes are for the input word requested.

To write the output word is used the function code 6, followed by 4 bytes (two for the start address of the object and two for the value

to be written). The expected response is composed of 4 bytes the same as those sent.

Related Topics

MB_RTU_Init

MB_RTU_Deinit

Page 188: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

187

1.16.10 MB_RTU_Wr_Coils

FUNCTION MB_RTU_Wr_Coils : UINT

VAR_INPUT

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS RTU function code 15: Write Multiple Coils.

Return Value

0 : success

144 : Quantity parameter not valid

146 : replay with address not valid

148 : replay with quantity not valid

Input Parameters

Slave_Add

Slave address (valid 1-247)

Address

Address of first bit to be write

Quantity

Number of bits to be write

Data

Pointer of data buffer for writing

Comments

The function writes the status of one or more bits of memory (Coils) into a specific slave using the MODBUS RTU protocol.

This is based on MB_RTU_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Slave_Add parameter selects the specific slave on serial bus.

Address parameter is the starting bit address to write.

Quantity parameter indicates the number of bits to be write.

Data parameter is the pointer of the buffer containing the values of the bits to be written. The LSB of the first byte of the buffer

contains the status to write into the addressed bit. The number of bytes in the buffer to be sent must be equal to: Data_Len = Quantity

/ 8, where if remainder > 0 then Data_Len = Data_Len + 1.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_RTU_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_RTU_Rd_Coils

MB_RTU_Wr_Single_Coil

Page 189: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

188

1.16.11 MB_RTU_Wr_Hold_Regs

FUNCTION MB_RTU_Wr_Hold_Regs : UINT

VAR_INPUT

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS RTU function code 16: Write Multiple Registers.

Return Value

0 : success

144 : Quantity parameter not valid

146 : replay with address not valid

148 : replay with quantity not valid

Input Parameters

Slave_Add

Slave address (valid 1-247)

Address

Address of first word to be write

Quantity

Number of words to be write

Data

Pointer of data buffer for writing

Comments

The function writes the status of one or more words of memory (Holding Registers) into a specific slave using the MODBUS RTU

protocol.

This is based on MB_RTU_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Slave_Add parameter selects the specific slave on serial bus.

Address parameter is the starting word address to write.

Quantity parameter indicates the number of words to be write.

Data parameter is the pointer of the buffer containing the values of the words to be written. The number of bytes in the buffer to be

sent must be equal to: Data_Len = 2 * Quantity.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_RTU_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_RTU_Rd_Hold_Regs

MB_RTU_Wr_Single_Reg

Page 190: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

189

1.16.12 MB_RTU_Wr_Rd_Hold_Regs

FUNCTION MB_RTU_Wr_Rd_Hold_Regs : UINT

VAR_INPUT

Slave_Add : BYTE;

Wr_Address : WORD;

Wr_Quantity : WORD;

Wr_Data : DWORD;

Rd_Address : WORD;

Rd_Quantity : WORD;

Rd_Data : DWORD;

END_VAR

Executes the MODBUS RTU function code 23: Write/Read Multiple Registers.

Return Value

0 : success

144 : Quantity parameter not valid

147 : replay with byte counter value not valid

Input Parameters

Slave_Add

Slave address (valid 1-247)

Wr_Address

Address of first word to be write

Wr_Quantity

Number of words to be write

Wr_Data

Pointer of data buffer for writing

Rd_Address

Address of first word to be read

Rd_Quantity

Number of words to be read

Rd_Data

Pointer of data buffer for reading

Comments

The function simultaneously writes and reads the value of one or more words of memory (Holding Registers) into and from a specific

slave using the MODBUS RTU protocol. This is based on MB_RTU_Req_Rsp generic communication function for which operates as

an interface with the specific command code.

Slave_Add parameter selects the specific slave on serial bus.

Wr_Address parameter is the starting word address to write.

Wr_Quantity parameter indicates the number of words to be write.

Wr_Data parameter is the pointer of the buffer containing the values of the words to be written. The number of bytes in the buffer to

be sent must be equal to: Wr_Data_Len = 2 * Wr_Quantity.

Rd_Address parameter is the starting word address to read.

Rd_Quantity parameter indicates the number of words to be read.

Rd_Data parameter is the pointer of the buffer in which receive the values of the words. The amount of bytes placed in the receive

buffer is equal to: Rd_Data_Len = 2 * Rd_Quantity.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_RTU_Req_Rsp function to which are added those of the specific command.

Page 191: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

190

Related Topics

MB_RTU_Rd_Hold_Regs

MB_RTU_Wr_Hold_Regs

Page 192: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

191

1.16.13 MB_RTU_Wr_Single_Coil

FUNCTION MB_RTU_Wr_Single_Coil : UINT

VAR_INPUT

Slave_Add : BYTE;

Address : WORD;

Value : WORD;

END_VAR

Executes the MODBUS RTU function code 5: Write Single Coil.

Return Value

0 : success

145 : Value parameter not valid

146 : replay with address not valid

149 : replay with value not valid

Input Parameters

Slave_Add

Slave address (valid 1-247)

Address

Address of bit to be write

Value

State to write into the bit: 16#0000=OFF, 16#FF00=ON

Comments

The function writes the status of single bit of memory (Coil) into a specific slave using the MODBUS RTU protocol.

This is based on MB_RTU_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Slave_Add parameter selects the specific slave on serial bus.

Address parameter is the bit address to write.

Value parameter indicates the status to be written into the bit. A value of 16#0000 forces the bit in the OFF state while the value

16#FF00 force the bit ON.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_RTU_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_RTU_Rd_Coils

MB_RTU_Wr_Coils

Page 193: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

192

1.16.14 MB_RTU_Wr_Single_Reg

FUNCTION MB_RTU_Wr_Single_Reg : UINT

VAR_INPUT

Slave_Add : BYTE;

Address : WORD;

Value : WORD;

END_VAR

Executes the MODBUS RTU function code 6: Write Single Register.

Return Value

0 : success

146 : replay with address not valid

149 : replay with value not valid

Input Parameters

Slave_Add

Slave address (valid 1-247)

Address

Address of word to be write

Value

Value to write into the word

Comments

The function writes the value of single word of memory (Holding Register) into a specific slave using the MODBUS RTU protocol.

This is based on MB_RTU_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Slave_Add parameter selects the specific slave on serial bus.

Address parameter is the word address to write.

Value parameter indicates the value to be written into the word.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_RTU_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_RTU_Rd_Hold_Regs

MB_RTU_Wr_Hold_Regs

Page 194: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

193

1.16.15 MB_RTU_Slave

FUNCTION BLOCK MB_RTU_Slave

VAR_INPUT

Start : BOOL;

Port : PORTS;

Baudrate : UDINT;

Parity : MB_RTU_PARITY;

Slave_Add : BYTE;

Coils_Ptr : POINTER TO BYTE;

Coils_Max : UINT;

Inputs_Ptr : POINTER TO BYTE;

Inputs_Max : UINT;

Hold_Regs_Ptr : POINTER TO WORD;

Hold_Regs_Max : UINT;

Input_Regs_Ptr : POINTER TO WORD;

Input_Regs_Max : UINT;

END_VAR

VAR_OUTPUT

Ready : BOOL;

Status : MODBUS_STATUS;

END_VAR

VAR

State : INT;

Frame_Timeout : UDINT;

Baud_Low : BOOL;

Delete_Echo : BOOL;

END_VAR

Function block to establish a permanent MODBUS RTU slave service.

Input Variables

Start

Activation signal.

Port

Serial port number. Default to COM2.

Baudrate

Speed of communication (300-1000000 bits/s). Default to 9600.

Parity

Parity select (0/1/2=NO/ODD/EVEN). Default to PARITY_EVEN.

Slave_Add

Slave address (valid 1-247). Default to 1.

Coils_Ptr

Pointer to bit addressable area for Coil elements

Coils_Max

Maximum number of Coil elements

Inputs_Ptr

Pointer to bit addressable area for Discrete Input elements

Inputs_Max

Page 195: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

194

Maximum number of Discrete Input elements

Hold_Regs_Ptr

Pointer to word addressable area for Holding Register elements

Hold_Regs_Max

Maximum number of Holding Register elements

Input_Regs_Ptr

Pointer to word addressable area for Input Register elements

Input_Regs_Max

Maximum number of Input Register elements

Output Variables

Ready

Service ready flag

Status

Current status of the service

Internal Variables

State

Current status of the state graph of the function block

Frame_Timeout

Calculated maximum time (x 1us) for frame receiving

Baud_Low

Selected baudrate is less/equal to 115200

Delete_Echo

Deleting of RS485 driver echo (automatically defined on specific hardware)

Comments

This function block installs a permanent slave service with MODBUS RTU protocol. The function block, once activated with the Start

signal, initializes the communication and then enter into a state of service activity. In the active state, the block awaits the arrival of a

command frame from MODBUS master. When the frame is received, it is checked and, if the command is correct for the specific

slave, the response is transmitted. To deactivate the service the Start signal must be forced FALSE.

Port parameter identifies the serial port (1-3) used for communication.

Coils_Ptr and Coils_Max parameters respectively define the pointer to the first byte of the area containing the bits associated with the

Coils block of the MODBUS memory model and the maximum number of addressable bits. The number of bits may not be a multiple

of 8, but the first bit must necessarily be aligned with the LSB of the first byte.

Similarly Inputs_Ptr and Inputs_Max parameters work relatively to the area containing the bits associated with Discrete inputs block of

the MODBUS memory model.

Hold_Regs_Ptr and Hold_Regs_Max parameters respectively define the pointer to the first word of the area containing the words

associated with the Holding Registers block of the MODBUS memory model and the maximum number of addressable words.

Similarly Input_Regs_Ptr and Input_Regs_Max parameters work relatively to the area containing the words associated with the Input

Registers block of the MODBUS memory model.

NOTE: all the elements of each block of the MODBUS model are contiguous and addressed from 0 coinciding with the initial position

of the memory area pointed by the supplied parameters.

Related Topics

Page 196: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

195

MODBUS_STATUS

Page 197: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

196

1.16.16 MB_TCP_Connect

FUNCTION MB_TCP_Connect : UINT

VAR_INPUT

IP_Address : STRING;

Port : UINT;

Keepalive_En : BOOL;

Keepalive_Time : INT;

Keepalive_Intv : INT;

Keepalive_Retry : INT;

Rsp_Timeout : UINT;

Socket : POINTER TO INT;

END_VAR

Initializes and connect MODBUS TCP/IP client to a specific server.

Return Value

0 : success

128 : initialization parameter not valid

129 : inizialization error

137 : reached the maximum number of instances (32)

>200 : error code according to the coding adopted by the TCP/IP stack

Input Parameters

IP_Address

Network address of the server to connect to

Port

Communication TCP/IP port of the server

Keepalive_En

Activation of Keepalive feature

Keepalive_Time

Idle time (s) before Probes sending (10-32767)

Keepalive_Intv

Time (s) interval between Probes (1-600)

Keepalive_Retry

Maximun number of Probes before connection close (0-32767)

Rsp_Timeout

Maximum wait (ms) for server response reception (for example 1000)

Socket

Returned socket descriptor to use as connection handle

Comments

This function initializes a MODBUS TCP/IP client connection with a server at a specific IP address. This function must be called

before start a communication session.

Up to 32 instances of simultaneous connection are possible with different socket handles.

IP_Address parameter identifies the network address of the server to which to connect.

The Port parameter identifies the TCP port used for connection. Normally the 502 port is used for MODBUS TCP/IP.

The Keepalive parameters set the feature of sending dummy messages (Probes) in order to check whether the connection with the

counterpart (server peer) is still active. If Keepalive_En is enabled and the connection is inactive for a time equal to Keepalive_Time,

Page 198: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

197

begins sending periodic TCP packets with no data (Probes) with a repetition time equal to Keepalive_Intv. After Keepalive_Retry

maximum attempts, if no answer is received from the connected device, the connection is automatically closed.

The Rsp_Timeout parameter sets the maximum waiting time in ms for the response from the server.

The function returns 0 if executed correctly. In this case the value returned on the Socket variable must be saved for use it in all other

client functions as a handle of the specific connection. In case of error the function returns a value > 0 that encodes the error.

Related Topics

MB_TCP_Disconnect

Page 199: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

198

1.16.17 MB_TCP_Disconnect

FUNCTION MB_TCP_Disconnect : UINT

VAR_INPUT

Socket : INT;

END_VAR

Disconnect MODBUS TCP/IP client from a specific server.

Return Value

0 : success

>200 : error code according to the coding adopted by the TCP/IP stack

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Comments

This function disconnects the MODBUS TCP/IP client from the server. This function must be called at the end of the MODBUS

session.

If Socket parameter value is -1, all previously opened connection instances will be closed.

If executed correctly returns 0 otherwise it returns the corresponding TCP/IP error code.

Related Topics

MB_TCP_Connect

Page 200: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

199

1.16.18 MB_TCP_Rd_Coils

FUNCTION MB_TCP_Rd_Coils : UINT

VAR_INPUT

Socket : INT;

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS TCP/IP function code 1: Read Coils.

Return Value

0 : success

144 : Quantity parameter not valid

147 : replay with byte counter value not valid

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Slave_Add

Slave address (valid 0-255)

Address

Address of first bit to be read

Quantity

Number of bits to be read

Data

Pointer of data buffer for reading

Comments

The function reads the status of one or more bits of memory (Coils) from a specific server/slave using the MODBUS TCP/IP protocol.

This is based on MB_TCP_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Socket parameter is the handle of the specific connection on which execute the request.

Slave_Add parameter select the specific slave on serial bus if the server is a gateway to a RTU subnet.

Address parameter is the starting bit address to read.

Quantity parameter indicates the number of bits to be read.

Data parameter is the pointer of the buffer in which receive the values of the bits. The LSB of the first byte of the buffer contains the

addressed bit. The amount of bytes placed in the receive buffer is equal to: Data_Len = Quantity / 8, where if remainder > 0 then

Data_Len = Data_Len + 1.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_TCP_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_TCP_Wr_Coils

MB_TCP_Wr_Single_Coil

Page 201: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

200

1.16.19 MB_TCP_Rd_Hold_Regs

FUNCTION MB_TCP_Rd_Hold_Regs : UINT

VAR_INPUT

Socket : INT;

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS TCP/IP function code 3: Read Holding Registers.

Return Value

0 : success

144 : Quantity parameter not valid

147 : replay with byte counter value not valid

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Slave_Add

Slave address (valid 0-255)

Address

Address of first word to be read

Quantity

Number of words to be read

Data

Pointer of data buffer for reading

Comments

The function reads the status of one or more words of memory (Holding Registers) from a specific server/slave using the MODBUS

TCP/IP protocol.

This is based on MB_TCP_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Socket parameter is the handle of the specific connection on which execute the request.

Slave_Add parameter select the specific slave on serial bus if the server is a gateway to a RTU subnet.

Address parameter is the starting word address to read.

Quantity parameter indicates the number of words to be read.

Data parameter is the pointer of the buffer in which receive the values of the words. The amount of bytes placed in the receive buffer

is equal to: Data_Len = 2 * Quantity.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_TCP_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_TCP_Wr_Hold_Regs

MB_TCP_Wr_Single_Reg

Page 202: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

201

1.16.20 MB_TCP_Rd_Input_Regs

FUNCTION MB_TCP_Rd_Input_Regs : UINT

VAR_INPUT

Socket : INT;

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS TCP/IP function code 4: Read Input Registers.

Return Value

0 : success

144 : Quantity parameter not valid

147 : replay with byte counter value not valid

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Slave_Add

Slave address (valid 0-255)

Address

Address of first word to be read

Quantity

Number of words to be read

Data

Pointer of data buffer for reading

Comments

The function reads the status of one or more words of input (Input Registers) from a specific server/slave using the MODBUS TCP/IP

protocol.

This is based on MB_TCP_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Socket parameter is the handle of the specific connection on which execute the request.

Slave_Add parameter select the specific slave on serial bus if the server is a gateway to a RTU subnet.

Address parameter is the starting word address to read.

Quantity parameter indicates the number of words to be read.

Data parameter is the pointer of the buffer in which receive the values of the words. The amount of bytes placed in the receive buffer

is equal to: Data_Len = 2 * Quantity.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_TCP_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_TCP_Rd_Inputs

Page 203: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

202

1.16.21 MB_TCP_Rd_Inputs

FUNCTION MB_TCP_Rd_Inputs : UINT

VAR_INPUT

Socket : INT;

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS TCP/IP function code 2: Read Discrete Inputs.

Return Value

0 : success

144 : Quantity parameter not valid

147 : replay with byte counter value not valid

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Slave_Add

Slave address (valid 0-255)

Address

Address of first bit to be read

Quantity

Number of bits to be read

Data

Pointer of data buffer for reading

Comments

The function reads the status of one or more bits of input (Discrete Inputs) from a specific server/slave using the MODBUS TCP/IP

protocol.

This is based on MB_TCP_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Socket parameter is the handle of the specific connection on which execute the request.

Slave_Add parameter select the specific slave on serial bus if the server is a gateway to a RTU subnet.

Address parameter is the starting bit address to read.

Quantity parameter indicates the number of bits to be read.

Data parameter is the pointer of the buffer in which receive the values of the bits. The LSB of the first byte of the buffer contains the

addressed bit. The amount of bytes placed in the receive buffer is equal to: Data_Len = Quantity / 8, where if remainder > 0 then

Data_Len = Data_Len + 1.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_TCP_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_TCP_Rd_Input_Regs

Page 204: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

203

1.16.22 MB_TCP_Req_Rsp

FUNCTION MB_TCP_Req_Rsp : UINT

VAR_INPUT

Socket : INT;

Slave_Add : BYTE;

Fun_Code : BYTE;

Req_Data : DWORD;

Req_Len : WORD;

Rsp_Data : DWORD;

Rsp_Len : WORD;

END_VAR

Executes a complete MODBUS TCP/IP request tx and response rx with a connected server.

Return Value

0 : success

1 : slave has received a not valid function code

2 : slave has received a not valid object address

3 : slave has received a not valid object data

4 : non-recoverable error during execution of the slave function

5 : response to prevent a master receive timeout while slave performs a long operation

6 : slave is busy in the execution of required function

130 : timeout during master reception

133 : bad slave address in replay

134 : bad function code in replay

136 : bad number of bytes received

138 : bad MBAP header in replay

>200 : error code according to the coding adopted by the TCP/IP stack

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Slave_Add

Slave address (valid 0-255)

Fun_Code

MODBUS function code

Req_Data

Pointer to request data buffer

Req_Len

Number of request data bytes

Rsp_Data

Pointer to response data buffer

Rsp_Len

Number of response data bytes aspected

Comments

This function execute a complete MODBUS TCP/IP communication sequence with a server on the network.

Socket parameter is the handle of the specific connection on which execute the request.

Slave_Add parameter selects the specific ID of a slave connected on a subnet over serial bus. This is used in the case of complex

networks realized with a gateway that convert between Modbus TCP/IP and RTU to address a specific slave within the subnet. The

Page 205: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

204

values 0-247 are normally assigned to a slave while the value 255 is used for the direct communication with the gateway or in the

absence of subnets.

Fun_Code parameter is the code of the function to execute.

Req_Data parameter is the pointer to the buffer with the data to be transmitted for the specific function code.

Req_Len parameter indicates the number of bytes in the Req_Data buffer to be transmitted to the slave.

Rsp_Data parameter is the pointer to the buffer in which receive the data of response to the function from the slave.

The Rsp_Len parameter indicates the number of data bytes expected in the Rsp_Data receive buffer as response to the specific

function code.

The function returns 0 if performed without error, otherwise it returns the error code.

To use the MODBUS communication function refer to the technical documentation "MODBUS Application Protocol Specification"

downloadable at http://www.modbus-ida.org./tech.php.

In the following example one input word and one output word are refreshed for the server 192.168.1.102:

PROGRAM MB_TCP VAR MB_TCP_Connected: BOOL := FALSE; MB_TCP_Socket: INT; Req_Buf: ARRAY[0..10] OF BYTE; Rsp_Buf: ARRAY[0..10] OF BYTE; Input_Reg: WORD; Output_Reg: WORD; END_VAR (* Initialize MODBUS connection *) IF NOT MB_TCP_Connected THEN IF MB_TCP_Connect('192.168.1.102', 502, TRUE, 7200, 75, 8, 1000, ADR(MB_TCP_Socket)) = 0 THEN MB_TCP_Connected := TRUE; END_IF END_IF (* Read one input word at address 0 from slave 255 (no RTU subnet) *) Req_Buf[0] := 0; Req_Buf[1] := 0; Req_Buf[2] := 0; Req_Buf[3] := 1; IF MB_TCP_Connected THEN IF MB_TCP_Req_Rsp(MB_TCP_Socket, 255, 4, ADR(Req_Buf), 4, ADR(Rsp_Buf), 3) = 0 THEN Input_Reg := 256 * Rsp_Buf[1] + Rsp_Buf[2]; END_IF END_IF (* Write one output word at address 1 to Slave 255 (no RTU subnet) *) Req_Buf[0] := 0; Req_Buf[1] := 1; Req_Buf[2] := Output_Reg / 256; Req_Buf[3] := Output_Reg MOD 256; IF MB_TCP_Connected THEN MB_TCP_Req_Rsp(MB_TCP_Socket, 255, 6, ADR(Req_Buf), 4, ADR(Rsp_Buf), 4); END_IF

To read the input word is used the function code 4, followed by 4 bytes of data (two for the start address of the object and two for the

amount of words to read). The expected response consists of 3 bytes of data. The first is a input bytes count (in this case 2 because

is required 1 word) while the remaining 2 bytes are for the input word requested.

To write the output word is used the function code 6, followed by 4 bytes (two for the start address of the object and two for the value

to be written). The expected response is composed of 4 bytes the same as those sent.

Related Topics

MB_TCP_Connect

Page 206: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

205

MB_TCP_Disconnect

Page 207: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

206

1.16.23 MB_TCP_Wr_Coils

FUNCTION MB_TCP_Wr_Coils : UINT

VAR_INPUT

Socket : INT;

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS TCP/IP function code 15: Write Multiple Coils.

Return Value

0 : success

144 : Quantity parameter not valid

146 : replay with address not valid

148 : replay with quantity not valid

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Slave_Add

Slave address (valid 0-255)

Address

Address of first bit to be write

Quantity

Number of bits to be write

Data

Pointer of data buffer for writing

Comments

The function writes the status of one or more bits of memory (Coils) into a specific server/slave using the MODBUS TCP/IP protocol.

This is based on MB_TCP_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Socket parameter is the handle of the specific connection on which execute the request.

Slave_Add parameter select the specific slave on serial bus if the server is a gateway to a RTU subnet.

Address parameter is the starting bit address to write.

Quantity parameter indicates the number of bits to be write.

Data parameter is the pointer of the buffer containing the values of the bits to be written. The LSB of the first byte of the buffer

contains the status to write into the addressed bit. The number of bytes in the buffer to be sent must be equal to: Data_Len = Quantity

/ 8, where if remainder > 0 then Data_Len = Data_Len + 1.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_TCP_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_TCP_Rd_Coils

MB_TCP_Wr_Single_Coil

Page 208: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

207

1.16.24 MB_TCP_Wr_Hold_Regs

FUNCTION MB_TCP_Wr_Hold_Regs : UINT

VAR_INPUT

Socket : INT;

Slave_Add : BYTE;

Address : WORD;

Quantity : WORD;

Data : DWORD;

END_VAR

Executes the MODBUS TCP/IP function code 16: Write Multiple Registers.

Return Value

0 : success

144 : Quantity parameter not valid

146 : replay with address not valid

148 : replay with quantity not valid

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Slave_Add

Slave address (valid 0-255)

Address

Address of first word to be write

Quantity

Number of words to be write

Data

Pointer of data buffer for writing

Comments

The function writes the status of one or more words of memory (Holding Registers) into a specific server/slave using the MODBUS

TCP/IP protocol.

This is based on MB_TCP_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Socket parameter is the handle of the specific connection on which execute the request.

Slave_Add parameter select the specific slave on serial bus if the server is a gateway to a RTU subnet.

Address parameter is the starting word address to write.

Quantity parameter indicates the number of words to be write.

Data parameter is the pointer of the buffer containing the values of the words to be written. The number of bytes in the buffer to be

sent must be equal to: Data_Len = 2 * Quantity.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_TCP_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_TCP_Rd_Hold_Regs

MB_TCP_Wr_Single_Reg

Page 209: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

208

1.16.25 MB_TCP_Wr_Rd_Hold_Regs

FUNCTION MB_TCP_Wr_Rd_Hold_Regs : UINT

VAR_INPUT

Socket : INT;

Slave_Add : BYTE;

Wr_Address : WORD;

Wr_Quantity : WORD;

Wr_Data : DWORD;

Rd_Address : WORD;

Rd_Quantity : WORD;

Rd_Data : DWORD;

END_VAR

Executes the MODBUS TCP/IP function code 23: Write/Read Multiple Registers.

Return Value

0 : success

144 : Quantity parameter not valid

147 : replay with byte counter value not valid

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Slave_Add

Slave address (valid 0-255)

Wr_Address

Address of first word to be write

Wr_Quantity

Number of words to be write

Wr_Data

Pointer of data buffer for writing

Rd_Address

Address of first word to be read

Rd_Quantity

Number of words to be read

Rd_Data

Pointer of data buffer for reading

Comments

The function simultaneously writes and reads the value of one or more words of memory (Holding Registers) into and from a specific

server/slave using the MODBUS TCP/IP protocol. This is based on MB_TCP_Req_Rsp generic communication function for which

operates as an interface with the specific command code.

Socket parameter is the handle of the specific connection on which execute the request.

Slave_Add parameter select the specific slave on serial bus if the server is a gateway to a RTU subnet.

Wr_Address parameter is the starting word address to write.

Wr_Quantity parameter indicates the number of words to be write.

Wr_Data parameter is the pointer of the buffer containing the values of the words to be written. The number of bytes in the buffer to

be sent must be equal to: Wr_Data_Len = 2 * Wr_Quantity.

Page 210: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

209

Rd_Address parameter is the starting word address to read.

Rd_Quantity parameter indicates the number of words to be read.

Rd_Data parameter is the pointer of the buffer in which receive the values of the words. The amount of bytes placed in the receive

buffer is equal to: Rd_Data_Len = 2 * Rd_Quantity.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_TCP_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_TCP_Rd_Hold_Regs

MB_TCP_Wr_Hold_Regs

Page 211: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

210

1.16.26 MB_TCP_Wr_Single_Coil

FUNCTION MB_TCP_Wr_Single_Coil : UINT

VAR_INPUT

Socket : INT;

Slave_Add : BYTE;

Address : WORD;

Value : WORD;

END_VAR

Executes the MODBUS TCP/IP function code 5: Write Single Coil.

Return Value

0 : success

145 : Value parameter not valid

146 : replay with address not valid

149 : replay with value not valid

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Slave_Add

Slave address (valid 0-255)

Address

Address of bit to be write

Value

State to write into the bit: 16#0000=OFF, 16#FF00=ON

Comments

The function writes the status of single bit of memory (Coil) into a specific server/slave using the MODBUS TCP/IP protocol.

This is based on MB_TCP_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Socket parameter is the handle of the specific connection on which execute the request.

Slave_Add parameter select the specific slave on serial bus if the server is a gateway to a RTU subnet.

Address parameter is the bit address to write.

Value parameter indicates the status to be written into the bit. A value of 16#0000 forces the bit in the OFF state while the value

16#FF00 force the bit ON.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_TCP_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_TCP_Rd_Coils

MB_TCP_Wr_Coils

Page 212: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

211

1.16.27 MB_TCP_Wr_Single_Reg

FUNCTION MB_TCP_Wr_Single_Reg : UINT

VAR_INPUT

Socket : INT;

Slave_Add : BYTE;

Address : WORD;

Value : WORD;

END_VAR

Executes the MODBUS TCP/IP function code 6: Write Single Register.

Return Value

0 : success

146 : replay with address not valid

149 : replay with value not valid

Input Parameters

Socket

Socket descriptor (handle) used by the connection

Slave_Add

Slave address (valid 0-255)

Address

Address of word to be write

Value

Value to write into the word

Comments

The function writes the value of single word of memory (Holding Register) into a specific server/slave using the MODBUS TCP/IP

protocol.

This is based on MB_TCP_Req_Rsp generic communication function for which operates as an interface with the specific command

code.

Socket parameter is the handle of the specific connection on which execute the request.

Slave_Add parameter select the specific slave on serial bus if the server is a gateway to a RTU subnet.

Address parameter is the word address to write.

Value parameter indicates the value to be written into the word.

The function returns 0 if it executes without error, otherwise it returns the error code. The error codes are those of the

MB_TCP_Req_Rsp function to which are added those of the specific command.

Related Topics

MB_TCP_Rd_Hold_Regs

MB_TCP_Wr_Hold_Regs

Page 213: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

212

1.16.28 MB_TCP_Server

FUNCTION BLOCK MB_TCP_Server

VAR_INPUT

Start : BOOL;

Port : UINT;

Keepalive_En : BOOL;

Keepalive_Time : INT;

Keepalive_Intv : INT;

Keepalive_Retry : INT;

Coils_Ptr : POINTER TO BYTE;

Coils_Max : UINT;

Inputs_Ptr : POINTER TO BYTE;

Inputs_Max : UINT;

Hold_Regs_Ptr : POINTER TO WORD;

Hold_Regs_Max : UINT;

Input_Regs_Ptr : POINTER TO WORD;

Input_Regs_Max : UINT;

END_VAR

VAR_OUTPUT

Ready : BOOL;

Status : MODBUS_STATUS;

END_VAR

VAR

State : INT;

Listen_Socket : INT;

Accepted_Socket : ARRAY[0..7] OF INT;

Highest_Socket : INT;

Socket_Flags : ARRAY[0..15] OF WORD;

END_VAR

Function block to establish a permanent MODBUS TCP/IP server function.

Input Variables

Start

Activation signal.

Port

TCP/IP port number. Default to 502.

Keepalive_En

Activation of Keepalive feature. Default to TRUE.

Keepalive_Time

Idle time (s) before Probes sending. Range 10-32767, default to 7200.

Keepalive_Intv

Time (s) interval between Probes. Range 1-600, default to 75.

Keepalive_Retry

Maximun number of Probes before connection close. Range 0-32767, default to 8.

Coils_Ptr

Pointer to bit addressable area for Coil elements

Coils_Max

Maximum number of Coil elements

Page 214: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

213

Inputs_Ptr

Pointer to bit addressable area for Discrete Input elements

Inputs_Max

Maximum number of Discrete Input elements

Hold_Regs_Ptr

Pointer to word addressable area for Holding Register elements

Hold_Regs_Max

Maximum number of Holding Register elements

Input_Regs_Ptr

Pointer to word addressable area for Input Register elements

Input_Regs_Max

Maximum number of Input Register elements

Output Variables

Ready

Service ready flag

Status

Current status of the service

Internal Variables

State

Current status of the state graph of the function block

Listen_Socket

Descriptor number of listen socket

Accepted_Socket

List of socket descriptor number of accepted connections

Highest_Socket

Maximum descriptor number of accepted connections

Socket_Flags

List of socket flags of accepted connections

Comments

This function block installs a permanent server service with MODBUS TCP/IP protocol. The function block, once activated with the

Start signal, initializes the connection and then enter into a state of service activity. In the active state, the block awaits the arrival of a

command frame from MODBUS client. When the frame is received, it is checked and, if the command is correct for the specific

server, the response is transmitted. To deactivate the service the Start signal must be forced FALSE.

Port parameter identifies the TCP port used for connection. Normally the 502 port is used for MODBUS TCP/IP.

A server can accept up to a maximum of 8 concurrent connections.

The Keepalive parameters set the feature of sending dummy messages (Probes) in order to check whether the connection with the

counterpart (client peer) is still active. If Keepalive_En is enabled and the connection is inactive for a time equal to Keepalive_Time,

begins sending periodic TCP packets with no data (Probes) with a repetition time equal to Keepalive_Intv. After Keepalive_Retry

maximum attempts, if no answer is received from the connected device, the connection is automatically closed.

Coils_Ptr and Coils_Max parameters respectively define the pointer to the first byte of the area containing the bits associated with the

Page 215: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

214

Coils block of the MODBUS memory model and the maximum number of addressable bits. The number of bits may not be a multiple

of 8, but the first bit must necessarily be aligned with the LSB of the first byte.

Similarly Inputs_Ptr and Inputs_Max parameters work relatively to the area containing the bits associated with Discrete inputs block of

the MODBUS memory model.

Hold_Regs_Ptr and Hold_Regs_Max parameters respectively define the pointer to the first word of the area containing the words

associated with the Holding Registers block of the MODBUS memory model and the maximum number of addressable words.

Similarly Input_Regs_Ptr and Input_Regs_Max parameters work relatively to the area containing the words associated with the Input

Registers block of the MODBUS memory model.

NOTE: all the elements of each block of the MODBUS model are contiguous and addressed from 0 coinciding with the initial position

of the memory area pointed by the supplied parameters.

Related Topics

MODBUS_STATUS

Page 216: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

215

1.16.29 MB_Swap_Dword

FUNCTION MB_Swap_Dword : DWORD

VAR_INPUT

Value : DWORD;

END_VAR

Big-endian/Little-endian conversion for the bytes of a DWORD.

Return Value

Double word value with swapped bytes

Input Parameters

Value

Value of the double word with the bytes to be swapped

Comments

The function performs the conversion from the Big-endian to the Little-endian notation and vice versa for a variable of type DWORD.

The double word returned by the function contains the same bytes of the double word passed as a parameter but in reverse order.

The PLC processor uses the Little-endian notation while the double words contained in the MODBUS protocol data packets are

defined with Big-endian notation. The implementation of custom MODBUS commands with the MB_RTU_Req_Rsp function may

require the use of conversion between the two formats. The insertion and estraction of a double word variable, related to a data buffer

of type ARRAY OF BYTE, require such conversion function.

Related Topics

MB_Swap_Dword2

MB_Swap_Word

Page 217: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

216

1.16.30 MB_Swap_Dword2

FUNCTION MB_Swap_Dword2 : DWORD

VAR_INPUT

Value : DWORD;

END_VAR

Big-endian/Little-endian conversion for the words of a DWORD.

Return Value

Double word value with swapped words

Input Parameters

Value

Value of the double word with the words to be swapped

Comments

The function performs the conversion from the Big-endian to the Little-endian notation and vice versa for a variable of type DWORD.

The double word returned by the function contains the same words of the double word passed as a parameter but in reverse order.

The PLC processor uses the Little-endian notation while the double words contained in the MODBUS protocol data packets are

defined with Big-endian notation. The implementation of custom MODBUS commands with the MB_RTU_Req_Rsp function may

require the use of conversion between the two formats. The insertion and estraction of a double word variable, related to a data buffer

of type ARRAY OF BYTE, require such conversion function.

Related Topics

MB_Swap_Dword

MB_Swap_Word

Page 218: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

217

1.16.31 MB_Swap_Word

FUNCTION MB_Swap_Word : WORD

VAR_INPUT

Value : WORD;

END_VAR

Big-endian/Little-endian conversion for the bytes of a WORD.

Return Value

Word value with swapped bytes

Input Parameters

Value

Value of the word with the bytes to be swapped

Comments

The function performs the conversion from the Big-endian to the Little-endian notation and vice versa for a variable of type WORD.

The word returned by the function contains the same bytes of the word passed as a parameter but in reverse order.

The PLC processor uses the Little-endian notation while the words contained in the MODBUS protocol data packets are defined with

Big-endian notation. The implementation of custom MODBUS commands with the MB_RTU_Req_Rsp function may require the use of

conversion between the two formats. The insertion and estraction of a word variable, related to a data buffer of type ARRAY OF

BYTE, require such conversion function.

In the case of the standard MODBUS commands, already implemented with specific functions, the word data conversions are handled

by the functions itself.

Related Topics

MB_Swap_Dword

MB_Swap_Dword2

Page 219: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

218

2. PLC Browser Commands

The PLC Browser (i.e. command line interpreter) is extended by some commands specific to the target. These commands include checking the

versions of the operating system and run-time kernel and setting and checking the IP configuration.

To execute a command, you must be logged into the controller. Then change to the PLC Browser by clicking on the "Resources" tab of the

project tree. Then double-click on "PLC-Browser", type the command into the first line of the PLC browser window and press the Enter key. The

controller's response to the command will be displayed in the lower area of the PLC-Browser window.

Here is a list of all extended commands available:

DHCP

DNSNAME

FTPPASSWORD

FTPUSER

GATEWAY

GETDATETIME

IP

IPCFG

IPETH

NETMASK

PING

REBOOT

SETDATETIME

TCPIPMEM

VER

WEBPASSWORD

WEBUSER

Page 220: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

219

2.1 DHCP

The DHCP command enables or disables the use of the Dynamic Host Configuration Protocol for the internal ethernet interface to obtain an IP

configuration.

When DHCP is enabled, it is not necessary to set the IP configuration manually using the commands IP, NETMASK and GATEWAY.

After setting the IP configuration or turning DHCP on or off, the ethernet interface must be reinitialized using the IPETH command.

Command Syntax: dhcp x where x is either 0 (DHCP off) or 1 (DHCP on)

Example: dhcp 1

Related Topics

GATEWAY command

IP command

IPETH command

NETMASK command

Page 221: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

220

2.2 DNSNAME

Change the current value of [DNS] NAME_SERVER1/2 entry into CHIP.INI file.

DNS server is a service to resolve the IP address value from a registered domain name.

NOTE: two name setting is available (1 and 2).

Command Syntax: dnsname n xxx.xxx.xxx.xxx

Example: dnsname 1 8.8.8.8

Page 222: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

221

2.3 FTPPASSWORD

Change the current value of [FTP] PASSWORD0/1 entry into CHIP.INI file.

User name and password registration protects access to FTP connection.

NOTE: two user setting is available (0 and 1).

Command Syntax: ftppassword n password

Example: ftppassword 0 ftp_password0

Related Topics

FTPUSER command

Page 223: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

222

2.4 FTPUSER

Change the current value of [FTP] USER0/1 entry into CHIP.INI file.

User name and password registration protects access to FTP connection.

NOTE: two user setting is available (0 and 1).

Command Syntax: ftpuser n user_name

Example: ftpuser 0 ftp_user0

Related Topics

FTPPASSWORD command

Page 224: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

223

2.5 GATEWAY

The GATEWAY command sets the address of the standard gateway of the ethernet interface.

After setting the IP configuration, the ethernet interface must be reinitialized using the IPETH command.

Command Syntax: gateway xxx.xxx.xxx.xxx

Example: gateway 192.168.1.1

Related Topics

IP command

IPETH command

NETMASK command

Page 225: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

224

2.6 GETDATETIME

The GETDATETIME command displays the current Date and Time of controller.

Command Syntax: getdatetime

Related Topics

SETDATETIME command

Page 226: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

225

2.7 IP

The IP command sets the IP address of the controller's ethernet interface. After setting the IP configuration, the ethernet interface must be

reinitialized using the IPETH command.

Command Syntax: ip xxx.xxx.xxx.xxx

Example: ip 192.168.1.101

Related Topics

GATEWAY command

IPETH command

NETMASK command

Page 227: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

226

2.8 IPCFG

The IPCFG command displays the current IP configuration of the controller. For each network interface, the device name, IP address, subnet

mask and related information are displayed.

Command Syntax: ipcfg

Page 228: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

227

2.9 IPETH

The IPETH command reconfigures the ethernet interface after the IP configuration has been changed using the IP, NETMASK, GATEWAY, or

DHCP command. If DHCP is enabled, IPETH also obtains a new IP configuration from the DHCP Server.

Command Syntax: ipeth

Related Topics

DHCP command

GATEWAY command

IP command

NETMASK command

Page 229: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

228

2.10 NETMASK

The NETMASK command sets the subnet mask of the ethernet interface.

After setting the IP configuration, the ethernet interface must be reinitialized using the IPETH command.

Command Syntax: netmask xxx.xxx.xxx.xxx

Example: netmask 255.255.255.0

Related Topics

GATEWAY command

IP command

IPETH command

Page 230: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

229

2.11 PING

The PING command allows to check if a particular other computer can be reached via the network.

After starting PING, four packets of data are sent to the other computer, which will then send a reply back to the controller. The result of the

PING (number of packets successfully received) will then be displayed in the PLC Browser. Note that while waiting for the reply, a series of

numbers is output in the PLC Browser to indicate that the command is still in process.

Command Syntax: ping xxx.xxx.xxx.xxx

Example: ping 192.168.1.2

Page 231: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

230

2.12 REBOOT

This command reboot the CPU and restart the execution of all services and programs.

NOTE: after this comand the communication with PLC is lost for some seconds.

Command Syntax: reboot

Page 232: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

231

2.13 SETDATETIME

The SETDATETIME command writes the updated Date and Time into controller.

The format of Date and Time is the same of DT data type.

Command Syntax: setdatetime yyyy-mm-dd-hh:mm:ss

Example: setdatetime 2010-04-29-16:35:40

Related Topics

GETDATETIME command

Page 233: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

232

2.14 TCPIPMEM

The TCPIPMEM command displays TCP/IP memory usage. This command shows the maximum reserved memory for the TCP/IP stack and the

current TCP/IP stack memory used.

Command Syntax: tcpipmem

Page 234: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

233

2.15 VER

The VER command displays the version numbers of the controller's operating system and of the controller's run-time kernel.

Command Syntax: ver

Page 235: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

234

2.16 WEBPASSWORD

Change the current value of [WEB] SEC_PASSWORD0/1 entry into CHIP.INI file.

User name and password registration protects access to WEB server connection.

NOTE: two user setting is available (0 and 1).

Command Syntax: webpassword n password

Example: webpassword 0 web_password0

Related Topics

WEBUSER command

Page 236: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

235

2.17 WEBUSER

Change the current value of [WEB] SEC_USER0/1 entry into CHIP.INI file.

User name and password registration protects access to WEB server connection.

NOTE: two user setting is available (0 and 1).

Command Syntax: webuser n user_name

Example: webuser 0 web_user0

Related Topics

WEBPASSWORD command

Page 237: Target CoDeSys Reference Manual - Overdigit.com · IEC-line by OVERDIGIT overdigit.com Target CoDeSys Reference Manual update: 13-04-2018

Target libraries

236

3. Error handling

The CoDeSys "error handling" concept.

CoDeSys uses events to handle runtime errors. A runtime error is an exception that occurs during the execution of an IEC project that disrupts

the normal flow of instructions. The occurrence of the exception makes the execution of the following intruction arguable, so the IEC project will

be stopped automaticly on the end of the current cycle. By registering an event handler it is possible to execute any IEC code. Bevor you restart

your program you have to reset it. Only when the exception EVENT_EXCPT_ETHLINKLOST occurs you can restart your program without a

reset.

All runtime errors are listed in the CoDeSys task configuration dialog.

The following exceptions (runtime errors) could be generated by the CoDeSys RTS:

1. EVENT_EXCPT_DIVIDEBYZERO: Division by zero (on integer datatypes) 2. EVENT_EXCPT_FPU_DIVIDEBYZERO: Division by zero (on floating point datatypes) 3. EVENT_EXCPT_FPU_INVALID_OPERATION: Floatingpoint operations with invalid input value (e.g. radical from -1) 4. EVENT_EXCPT_NETWORKERROR: Fatal network/TCP-IP error (mostly an memory problem) 5. EVENT_EXCPT_HARDWAREERROR: Fatal hardware error (e.g. flash defect, ethernet controller defect) 6. EVENT_EXCPT_OUTOFMEMORY: Not enough memory available 7. EVENT_EXCPT_ILLEGAL_INSTRUCTION: Unknown processor instruction 8. EVENT_EXCPT_KERNELERROR: Internal kernel error 9. EVENT_EXCPT_ETHLINKLOST: Ethernet link lost