Librairie technique, scientifique & industrielle Novembre 2014 - BO256 Réservoirs et conteneurs fixes API Std 653-2014 Tank Inspection, Repair, Alteration, and Reconstruction API Std 653 5ème édition Tank Inspection, Repair, Alteration, and Reconstruction This standard covers steel storage tanks built to API 650 and its predecessor API 12C. It provides minimum requirements for maintaining the integrity of such tanks after they have been placed in service and addresses inspection, repair, alteration, relocation, and reconstruction. This standard employs the principles of API 650; however, storage tank owner/operators, based on consideration of specific construction and operating details, may apply this standard to any steel tank constructed in accordance with a tank specification. This standard is intended for use by organizations that maintain or have access to engineering and inspection personnel technically trained and experienced in tank design, fabrication, repair, construction, and inspection. Nous vous conseillons également la norme suivante : API Std 650-2013 : Tank Inspection, Repair, Alteration, and Reconstruction 12éme Edition + Erratum 1 (2013) & Addendim 1 (2014) This standard establishes minimum requirements for material, design, fabrication, erection, and inspection for vertical, cylindrical, aboveground, closed- and open-top, welded storage tanks in various sizes and capacities for internal pressures approximating atmospheric pressure (internal pressures not exceeding the weight of the roof plates), but a higher internal pressure is permitted when additional requirements are met. This standard applies only to tanks whose entire bottom is uniformly supported and to tanks in non-refrigerated service that have a maximum design temperature of 93 °C (200 °F) or less. Edition 2014 Retrouvez l’essentiel des documents relatifs aux réservoirs et conteneurs fixes Bon de commande au dos à nous retourner par fax, email ou courrier ou commandez en ligne a +33 1 40 02 03 12 a [email protected]a www.normadoc.com NORMADOC 12, Rue de Capri - F-75012 Paris www.normadoc.com FRANCE [email protected]API Std 650 Tarif € HT : 380,00 Editeur : American Petroleum Inst. Date de parution : 11.2014 Nombre de pages : 174 Format : PDF API Std 650 & 653 Tarif € HT : 468,00 API Std 653 Tarif € HT : 188,00 _ARCHIVES
2
Embed
Tank Inspection, Repair, Alteration, and Reconstruction ... · Librairie technique, scientifique & industrielle Novembre 2014 - BO256. Réservoirs et conteneurs fixes. API Std 653-2014.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Librairie technique, scientifique & industrielle Novembre 2014 - BO256
Réservoirs et conteneurs fixes
API Std 653-2014Tank Inspection, Repair, Alteration, and Reconstruction
API Std 653 5ème éditionTank Inspection, Repair, Alteration,
and ReconstructionThis standard covers steel storage tanks built to API 650 and its predecessor API 12C. It provides minimum requirements for maintaining the integrity of such tanks after they have been placed in service and addresses inspection, repair, alteration, relocation, and reconstruction.This standard employs the principles of API 650; however, storage tank owner/operators, based on consideration of specific construction and operating details, may apply this standard to any steel tank constructed in accordance with a tank specification.This standard is intended for use by organizations that maintain or have access to engineering and inspection personnel technically trained and experienced in tank design, fabrication, repair, construction, and inspection.
Nous vous conseillons également la norme suivante :
API Std 650-2013 : Tank Inspection, Repair, Alteration, and Reconstruction12éme Edition + Erratum 1 (2013) & Addendim 1 (2014)
This standard establishes minimum requirements for material, design, fabrication, erection, and inspection for vertical, cylindrical, aboveground, closed- and open-top, welded storage tanks
in various sizes and capacities for internal pressures approximating atmospheric pressure (internal pressures not exceeding the weight of the roof plates), but a higher internal pressure is permitted when additional requirements are met. This standard applies only to tanks whose entire bottom is uniformly supported and to tanks in non-refrigerated service that have a maximum design temperature of 93 °C (200 °F) or less.
Edition 2014
Retrouvez l’essentiel des documents relatifs auxréservoirs et conteneurs fixes
Bon de commande au dosà nous retourner par fax, email ou courrier ou commandez en ligne
ASTM VOL 01.04 Online Basic 2014 anglais en ligne 208,00 € 219,44 €
Total TTC1 Frais de port & gestionj 6.50 € 7.80€ 7,80 €
jFrais de port hors France métropolitaine : nous consulterTVA : 5,5 % pour document - 20 % pour port
Net à payer
Bon de commande à nous retourner avec votre règlement : q par courrier : 12, Rue de Capri - F-75012 PARIS - FRANCE q par Fax : + 33 (0)1 40 02 03 12 q par Email : [email protected]
Vous pouvez également commander sur notre site : www.normadoc.com