TAG: SUBMITTAL€¦ · TAG: 15 SERIES Multi Zone Mini-Split Inverter System M4THM1518A12NA M4THM1518A-SUB-1A-EN Specifications MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Outdoor UnitRated Cooling Capacity Cooling Capacity Range (Btu/h)Rated Heating CapacityHeating Capacity Range @ 47 F (Btu/h)Max. Heating Capacity @ 17 F (Btu/h)Max Heating Capacity @ 5 F (Btu/h)SEER / HSPFEERCompressor TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F) Cooling/HeatingCondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x height (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Fuse (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A)1Uncrated Dimension (W/D/H) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAM.O.P
Connection PipeOuter Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft) - Single Unit EachMax Length Distance (ft) - Multiple Units Total
1 Sound PRESSURE Level @ 3.3 ft. dB(A)
M4THM1518A12NA
208 / 230 / 1 60Hz
M4THM1518A12NA18000
7000 - 2100019000
8530 - 226009600 8600
15.0 / 8.210.0
Inverter Rotary27
9.561245EEV
0 ~ 118 5 ~ 75Aluminum Fin-Copper Tube
5/162 - 0.055
30.6 x 1.5 x 21.7830 / 670 / 500
600.5420
153017.5
Automatic Defrosting6656
35.4 x 14.9 x 23.537.3 x 16.5 x 25.4
94.8 / 105.847.6313.020.0
1/43/81/43/8//////
163375
35.4
32.1
23.5
14.9
12.4
13.5
21.6
18K Unit
NOTES:• The refrigerant charge mentioned in the technical data does not include additional charge required
for the indoor unit(s) and the refrigerant pipe. • The amount of the additional refrigerant charge depends on the length of the liquid refrigerant pipe
installed and the number of indoor units connected. • Record the additional refrigerant charge for future maintenance.
Calculation of the Additional Refrigerant Charge: Unit: Feet
M4THM1518 M4THM1524 M4THM1530 M4THM1536 M4THM1542
Maximum total length 75 230 230 230 260
Maximum length to single IDU 33 65 65 65 80
Minimum distance to single IDU 10 10 10 10 10
Maximum ODU/IDU height difference 16 33 33 50 50
Maximum IDU/IDU height difference 16 25 25 25 25
Maximum w/o adding charge 66 100 130 130 165
Minimum w/o removing charge 33 50 65 80 100
Amount of R410-A +/- (oz/ft) 0.22 0.22 0.22 0.24 0.24
This unit comes pre-charged with refriger-ant from the factory. It is designed to operate at outdoor ambient temperatures as high as 118°F. Cooling capacities with its associated indoor units shown in the catalog are AHRI certified. It is also ETL listed for outdoor ap-plication.
Unit Casing
The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include a condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard
Compressor
The compressor features internal over temperature and over pressure protec-tion; it also has dipped hermetic motor windings. Other features include: a centrifugal oil pump and low vibration and noise.
Condenser Coil
The coil consists of aluminum finned coils brazed to copper tubing. It provides air flow resistance, efficient heat transfer, and is protected by the casing.
Low Ambient Cooling
Matched ductless products have a cooling capability to 0° F.
Outdoor UnitRated Cooling Capacity Cooling Capacity Range (Btu/h)Rated Heating CapacityHeating Capacity Range @ 47 F (Btu/h)Max. Heating Capacity @ 17 F (Btu/h)Max Heating Capacity @ 5 F (Btu/h)SEER / HSPFEERCompressor TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F) Cooling/HeatingCondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x height (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Fuse (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A)1Uncrated Dimension (W/D/H) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAM.O.P
Connection PipeOuter Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft) - Single Unit EachMax Length Distance (ft) - Multiple Units Total
1 Sound PRESSURE Level @ 3.3 ft. dB(A)
M4THM1524A13NA
208 / 230 / 1 60Hz
M4THM1524A13NA26000
7500 - 3300029000
7500 - 350001500012100
15.0 / 8.28.0
Inverter Rotary45
14.692200EEV
0 ~ 118 5 ~ 75Aluminum Fin-Copper Tube
3/82 - 0.055
35.0 x 1.7 x 25.0690 / 600 / 500
600.5930
153020.5
Automatic Defrosting6656
37.2 x 15.6 x 27.640.5 x 18.0 x 29.5
134.5 / 145.577.6220.030.0
1/43/81/43/81/43/8////
3365230
35.1
37.2
27.6
15.6
13.4
22.014
.5
24K-30K Unit
Unit: Feet
M4THM1518 M4THM1524 M4THM1530 M4THM1536 M4THM1542
Maximum total length 75 230 230 230 260
Maximum length to single IDU 33 65 65 65 80
Minimum distance to single IDU 10 10 10 10 10
Maximum ODU/IDU height difference 16 33 33 50 50
Maximum IDU/IDU height difference 16 25 25 25 25
Maximum w/o adding charge 66 100 130 130 165
Minimum w/o removing charge 33 50 65 80 100
Amount of R410-A +/- (oz/ft) 0.22 0.22 0.22 0.24 0.24
NOTES:• The refrigerant charge mentioned in the technical data does not include additional charge required
for the indoor unit(s) and the refrigerant pipe. • The amount of the additional refrigerant charge depends on the length of the liquid refrigerant pipe
installed and the number of indoor units connected. • Record the additional refrigerant charge for future maintenance.
Calculation of the Additional Refrigerant Charge:
Indoor Unit Combinations with Associated Nominal Capacity (kBTUH)
This unit comes pre-charged with refriger-ant from the factory. It is designed to operate at outdoor ambient temperatures as high as 118°F. Cooling capacities with its associated indoor units shown in the catalog are AHRI certified. It is also ETL listed for outdoor ap-plication.
Unit Casing
The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include a condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard
Compressor
The compressor features internal over temperature and over pressure protec-tion; it also has dipped hermetic motor windings. Other features include: a centrifugal oil pump and low vibration and noise.
Condenser Coil
The coil consists of aluminum finned coils brazed to copper tubing. It provides air flow resistance, efficient heat transfer, and is protected by the casing.
Low Ambient Cooling
Matched ductless products have a cooling capability to 0° F.
Outdoor UnitRated Cooling Capacity Cooling Capacity Range (Btu/h)Rated Heating CapacityHeating Capacity Range @ 47 F (Btu/h)Max. Heating Capacity @ 17 F (Btu/h)Max Heating Capacity @ 5 F (Btu/h)SEER / HSPFEERCompressor TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F) Cooling/HeatingCondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x height (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Fuse (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A)1Uncrated Dimension (W/D/H) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAM.O.P
Connection PipeOuter Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft) - Single Unit EachMax Length Distance (ft) - Multiple Units Total
1 Sound PRESSURE Level @ 3.3 ft. dB(A)
35.1
37.2
27.6
15.6
13.4
22.014
.5
24K-30K Unit
Unit: Feet
M4THM1518 M4THM1524 M4THM1530 M4THM1536 M4THM1542
Maximum total length 75 230 230 230 260
Maximum length to single IDU 33 65 65 65 80
Minimum distance to single IDU 10 10 10 10 10
Maximum ODU/IDU height difference 16 33 33 50 50
Maximum IDU/IDU height difference 16 25 25 25 25
Maximum w/o adding charge 66 100 130 130 165
Minimum w/o removing charge 33 50 65 80 100
Amount of R410-A +/- (oz/ft) 0.22 0.22 0.22 0.24 0.24
NOTES:• The refrigerant charge mentioned in the technical data does not include additional charge required
for the indoor unit(s) and the refrigerant pipe. • The amount of the additional refrigerant charge depends on the length of the liquid refrigerant pipe
installed and the number of indoor units connected. • Record the additional refrigerant charge for future maintenance.
This unit comes pre-charged with refriger-ant from the factory. It is designed to operate at outdoor ambient temperatures as high as 118°F. Cooling capacities with its associated indoor units shown in the catalog are AHRI certified. It is also ETL listed for outdoor ap-plication.
Unit Casing
The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include a condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard
Compressor
The compressor features internal over temperature and over pressure protec-tion; it also has dipped hermetic motor windings. Other features include: a centrifugal oil pump and low vibration and noise.
Condenser Coil
The coil consists of aluminum finned coils brazed to copper tubing. It provides air flow resistance, efficient heat transfer, and is protected by the casing.
Low Ambient Cooling
Matched ductless products have a cooling capability to 0° F.
Outdoor UnitRated Cooling Capacity Cooling Capacity Range (Btu/h)Rated Heating CapacityHeating Capacity Range @ 47 F (Btu/h)Max. Heating Capacity @ 17 F (Btu/h)Max Heating Capacity @ 5 F (Btu/h)SEER / HSPFEERCompressor TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F) Cooling/HeatingCondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x height (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Fuse (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A)1Uncrated Dimension (W/D/H) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAM.O.P
Connection PipeOuter Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft) - Single Unit EachMax Length Distance (ft) - Multiple Units Total
1 Sound PRESSURE Level @ 3.3 ft. dB(A)
16.839.1
36.2
24.0
14.6
31.1
15.6
Unit: Feet
M4THM1518 M4THM1524 M4THM1530 M4THM1536 M4THM1542
Maximum total length 75 230 230 230 260
Maximum length to single IDU 33 65 65 65 80
Minimum distance to single IDU 10 10 10 10 10
Maximum ODU/IDU height difference 16 33 33 50 50
Maximum IDU/IDU height difference 16 25 25 25 25
Maximum w/o adding charge 66 100 130 130 165
Minimum w/o removing charge 33 50 65 80 100
Amount of R410-A +/- (oz/ft) 0.22 0.22 0.22 0.24 0.24
NOTES:• The refrigerant charge mentioned in the technical data does not include additional charge required
for the indoor unit(s) and the refrigerant pipe. • The amount of the additional refrigerant charge depends on the length of the liquid refrigerant pipe
installed and the number of indoor units connected. • Record the additional refrigerant charge for future maintenance.
This unit comes pre-charged with refriger-ant from the factory. It is designed to operate at outdoor ambient temperatures as high as 118°F. Cooling capacities with its associated indoor units shown in the catalog are AHRI certified. It is also ETL listed for outdoor ap-plication.
Unit Casing
The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include a condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard
Compressor
The compressor features internal over temperature and over pressure protec-tion; it also has dipped hermetic motor windings. Other features include: a centrifugal oil pump and low vibration and noise.
Condenser Coil
The coil consists of aluminum finned coils brazed to copper tubing. It provides air flow resistance, efficient heat transfer, and is protected by the casing.
Low Ambient Cooling
Matched ductless products have a cooling capability to 0° F.
Outdoor UnitRated Cooling Capacity Cooling Capacity Range (Btu/h)Rated Heating CapacityHeating Capacity Range @ 47 F (Btu/h)Max. Heating Capacity @ 17 F (Btu/h)Max Heating Capacity @ 5 F (Btu/h)SEER / HSPFEERCompressor TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F) Cooling/HeatingCondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x height (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Fuse (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A)1Uncrated Dimension (W/D/H) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAM.O.P
Connection PipeOuter Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft) - Single Unit EachMax Length Distance (ft) - Multiple Units Total
1 Sound PRESSURE Level @ 3.3 ft. dB(A)
40.0
42.8
24.8
17.3
14.3
15.8
43.4
42K Unit
Unit: Feet
M4THM1518 M4THM1524 M4THM1530 M4THM1536 M4THM1542
Maximum total length 75 230 230 230 260
Maximum length to single IDU 33 65 65 65 80
Minimum distance to single IDU 10 10 10 10 10
Maximum ODU/IDU height difference 16 33 33 50 50
Maximum IDU/IDU height difference 16 25 25 25 25
Maximum w/o adding charge 66 100 130 130 165
Minimum w/o removing charge 33 50 65 80 100
Amount of R410-A +/- (oz/ft) 0.22 0.22 0.22 0.24 0.24
NOTES:• The refrigerant charge mentioned in the technical data does not include additional charge required
for the indoor unit(s) and the refrigerant pipe. • The amount of the additional refrigerant charge depends on the length of the liquid refrigerant pipe
installed and the number of indoor units connected. • Record the additional refrigerant charge for future maintenance.
The manufacturer has a policy of continuous product and product data improvement and it reserves the right
to change design and specifications without notice.
Mechanical Specifications
Multi-Zone Outdoor Unit
General
This unit comes pre-charged with refriger-ant from the factory. It is designed to operate at outdoor ambient temperatures as high as 118°F. Cooling capacities with its associated indoor units shown in the catalog are AHRI certified. It is also ETL listed for outdoor ap-plication.
Unit Casing
The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include a condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard
Compressor
The compressor features internal over temperature and over pressure protec-tion; it also has dipped hermetic motor windings. Other features include: a centrifugal oil pump and low vibration and noise.
Condenser Coil
The coil consists of aluminum finned coils brazed to copper tubing. It provides air flow resistance, efficient heat transfer, and is protected by the casing.
Low Ambient Cooling
Matched ductless products have a cooling capability to 0° F.
08/17
Optional Equipment
Optional outdoor unit accessories M4THM15Model Multi-ZoneNumber Description up to 15 SEERTAYREFLN050 ....................... Lineset Kit 1/4x3/8 - 25' .................................................................. ✔