A&E OFFICE: 2595 DALLAS PKWY FRISCO, TX 75034 (972) 581-9888 TRANSFORM YOUR BUSINESS...THROUGH WIRELESS PREPARED BY: CLIENT: PROFESSIONAL STAMP: SITE INFORMATION: DRAWN BY: CHECKED BY: SHEET TITLE: SHEET NUMBER: DATE: DATE: REV DATE DESCRIPTION BY SUBMITTALS Mobility RING NAME: RING NUMBER: FA LOCATION CODE: ADDRESS: PACE ID: PROJECTS: FOR ZONING · · · · · · T-1 RING NAME: SITE INFORMATION SHEET INDEX VICINITY MAP NORTH Know what's below. before you dig. Call R APPROVALS SITE CODE COMPLIANCE · · · · · · RING NUMBER: FA NUMBER: PACE NUMBER: AT&T SITE ADDRESS: NSB-CO.BDN_Add_4591_COL02148 COL02148 12871723 MRUTH029076 17925 US HWY 24 PEYTON, CO 80831 STRUCTURE TYPE: 199'-0" MONOPOLE TOWER PROJECT TYPE: NEW SITE BUILD GENERAL NOTES DRIVING DIRECTIONS SCOPE OF WORK · · · · · · · · · · · · · · · · · · · · USID 265337 PROJECTS Mobility
5

T-1 · 2019-08-07 · project type: new site build general notes driving directions scope of work ... 2595 dallas pkwy frisco, tx 75034 (972) 581-9888. transform your business...through

Jul 13, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: T-1 · 2019-08-07 · project type: new site build general notes driving directions scope of work ... 2595 dallas pkwy frisco, tx 75034 (972) 581-9888. transform your business...through

A&E OFFICE:

2595 DALLAS PKWY FRISCO, TX 75034

(972) 581-9888

TRANSFORM YOUR BUSINESS...THROUGH WIRELESS

PREPARED BY:

CLIENT:

PROFESSIONAL STAMP:

SITE INFORMATION:

DRAWN BY:

CHECKED BY:

SHEET TITLE:

SHEET NUMBER:

DATE:

DATE:

REV DATE DESCRIPTION BY

SUBMITTALS

Mobility

RING NAME:

RING NUMBER:

FA LOCATION CODE:

ADDRESS:

PACE ID:

PROJECTS:

FOR ZONING

··

···

·

T-1

RING NAME:

SITE INFORMATION SHEET INDEXVICINITY MAP

NORTH

Know what's below.before you dig.Call

R

APPROVALS

SITE

CODE COMPLIANCE

···

·

··

RING NUMBER:

FA NUMBER:

PACE NUMBER:

AT&T SITE ADDRESS:

NSB-CO.BDN_Add_4591_COL02148

COL02148

12871723

MRUTH029076

17925 US HWY 24PEYTON, CO 80831

STRUCTURE TYPE: 199'-0" MONOPOLE TOWER

PROJECT TYPE: NEW SITE BUILD

GENERAL NOTES

DRIVING DIRECTIONS

SCOPE OF WORK ·

····

·

·

·

·

·

·

·

········

USID 265337

PROJECTS

Mobility

AutoCAD SHX Text
A
AutoCAD SHX Text
05/24/19
AutoCAD SHX Text
FOR REVIEW
AutoCAD SHX Text
RA
AutoCAD SHX Text
B
AutoCAD SHX Text
05/30/19
AutoCAD SHX Text
FOR REVIEW
AutoCAD SHX Text
RA
AutoCAD SHX Text
RA
AutoCAD SHX Text
CD
AutoCAD SHX Text
05/24/19
AutoCAD SHX Text
05/30/19
AutoCAD SHX Text
161 INVERNESS DR W, 2ND FLOOR ENGLEWOOD, COLORADO 80112
AutoCAD SHX Text
NSB-CO.BDN_Add_4591_COL02148
AutoCAD SHX Text
COL02148
AutoCAD SHX Text
12871723
AutoCAD SHX Text
17925 US HWY 24
AutoCAD SHX Text
PEYTON, CO 80831, CO 80831CO 80831 8083180831
AutoCAD SHX Text
MRUTH029076
AutoCAD SHX Text
THIS DOCUMENT IS THE DESIGN PROPERTY AND COPYRIGHT OF NEXIUS AND FOR THE EXCLUSIVE USE BY THE TITLE CLIENT. DUPLICATION OR USE WITHOUT THE EXPRESS WRITTEN CONSENT OF THE CREATOR IS STRICTLY PROHIBITED.
AutoCAD SHX Text
LTE 1C / 2C / 3C / 4C / 5C / 6C
AutoCAD SHX Text
ZONING DOCUMENTS THESE DOCUMENTS ARE RELEASED FOR THE PURPOSE OF ZONING UNDER THE AUTHORITY OF JACK T. PHIPPS ON 05/30/19. 05/30/19. . JACK T. PHIPPS, P.E. COLORADO PROFESSIONAL ENGINEER REGISTRATION NUMBER P-17909 EXPIRATION DATE 10/31/2019 NEXIUS SOLUTION, INC. COLORADO FIRM NO. C-3797 EXPIRATION DATE 08/31/2019
AutoCAD SHX Text
TITLE SHEET
AutoCAD SHX Text
SHEET #
AutoCAD SHX Text
SHEET DESCRIPTION
AutoCAD SHX Text
T-1
AutoCAD SHX Text
TITLE SHEET
AutoCAD SHX Text
ZD-1
AutoCAD SHX Text
AERIAL MAP
AutoCAD SHX Text
ZD-2
AutoCAD SHX Text
OVERALL SITE PLAN
AutoCAD SHX Text
ZD-3
AutoCAD SHX Text
ENLARGED SITE PLAN
AutoCAD SHX Text
ZD-4
AutoCAD SHX Text
PROPOSED TOWER PLAN AND ELEVATION
AutoCAD SHX Text
NEXIUS LEASING/SITE ACQUISITION: NEXIUS A&E: NEXIUS CM: AT&T CM: AT&T RF:
AutoCAD SHX Text
DATE: DATE: DATE: DATE: DATE:
AutoCAD SHX Text
THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND MAY IMPOSE CHANGES OR MODIFICATIONS.
AutoCAD SHX Text
ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH CURRENT EDITIONS OF THE FOLLOWING APPLICABLE CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. 2015 INTERNATIONAL BUILDING CODE 2017 NATIONAL ELECTRICAL SAFETY CODE 2017 NATIONAL ELECTRICAL CODE TIA/EIA-222-G-2 OR LATEST EDITION ADOPTED CITY/COUNTY ORDINANCES ALL CODES SUBJECT TO LOCAL JURISDICTION REQUIREMENTS
AutoCAD SHX Text
RING NAME:
AutoCAD SHX Text
NSB-CO.BDN_Add_4591_COL02148
AutoCAD SHX Text
RING NUMBER:
AutoCAD SHX Text
COL02148
AutoCAD SHX Text
FA LOCATION CODE:
AutoCAD SHX Text
12871723
AutoCAD SHX Text
ADDRESS:
AutoCAD SHX Text
17925 US HWY 24
AutoCAD SHX Text
CITY, STATE ZIP:
AutoCAD SHX Text
PEYTON, CO 80831, CO 80831CO 80831 8083180831
AutoCAD SHX Text
COUNTY:
AutoCAD SHX Text
EL PASO
AutoCAD SHX Text
LATITUDE:
AutoCAD SHX Text
39.016671 °
AutoCAD SHX Text
LONGITUDE:
AutoCAD SHX Text
-104.493231 °
AutoCAD SHX Text
GROUND ELEVATION:
AutoCAD SHX Text
6812' A.M.S.L. A.M.S.L.
AutoCAD SHX Text
STRUCTURE TYPE:
AutoCAD SHX Text
MONOPOLE TOWER
AutoCAD SHX Text
STRUCTURE HEIGHT:
AutoCAD SHX Text
199'-0" A.G.L. A.G.L.
AutoCAD SHX Text
APPLICANT:
AutoCAD SHX Text
AT&T MOBILITY 161 INVERNESS DR W, 2ND FLOOR ENGLEWOOD, COLORADO 80112
AutoCAD SHX Text
SITE ACQUISITION:
AutoCAD SHX Text
NEXIUS SOLUTIONS, INC. 8310 SOUTH VALLEY HWY, 3RD FLOOR, STE 3131 ENGLEWOOD, CO 80112
AutoCAD SHX Text
A&E SERVICES:
AutoCAD SHX Text
NEXIUS SOLUTIONS, INC. 2595 DALLAS PKWY FRISCO, TX 75034 (972) 581-9888
AutoCAD SHX Text
TOWER OWNER:
AutoCAD SHX Text
TBD
AutoCAD SHX Text
JURISDICTION:
AutoCAD SHX Text
EL PASO COUNTY COUNTY
AutoCAD SHX Text
PARCEL #:
AutoCAD SHX Text
3200000405
AutoCAD SHX Text
ZONING DESIGNATION:
AutoCAD SHX Text
A-35: AGRICULTURAL
AutoCAD SHX Text
THE FACILITY IN UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE. POTABLE WATER OR TRASH DISPOSAL IS NOT REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED. THIS DRAWING IS SIZED TO 34" X 22" FOR SCALING PURPOSES.
AutoCAD SHX Text
FROM AT&T OFFICE: : GET ON I-25 S IN CENTENNIAL FROM INVERNESS BLVD AND E DRY CREEK RD HEAD NORTHEAST TOWARD INVERNESS DR W TURN LEFT TOWARD INVERNESS BLVD TURN RIGHT ONTO INVERNESS BLVD TURN LEFT AT THE 1ST CROSS STREET ONTO INVERNESS DR W USE THE LEFT LANE TO TURN LEFT ONTO E DRY CREEK RD USE THE LEFT 2 LANES TO TURN LEFT TO MERGE ONTO I-25 S FOLLOW I-25 S TO S COUNTY LINE RD/PALMER DIVIDE RD IN DOUGLAS COUNTY. TAKE EXIT 163 FROM I-25 S MERGE ONTO I-25 S TAKE EXIT 163 FOR COUNTY LINE RD TOWARD PALMER LAKE CONTINUE ON S COUNTY LINE RD/PALMER DIVIDE RD. TAKE CO-83 S AND HODGEN RD TO US-24 W IN PEYTON TURN LEFT ONTO S COUNTY LINE RD/PALMER DIVIDE RD TURN RIGHT ONTO CO-83 S TURN LEFT ONTO HODGEN RD TURN RIGHT ONTO EASTONVILLE RD TURN LEFT ONTO SWEET RD TURN RIGHT ONTO ELBERT RD TURN LEFT ONTO MURPHY RD TURN RIGHT ONTO BRADSHAW RD TURN RIGHT ONTO US-24 W
AutoCAD SHX Text
THE PURPOSE OF THIS PROJECT IS AS FOLLOWS: TOWER SCOPE OF WORK: -INSTALLATION OF (12) PANEL ANTENNAS -INSTALLATION OF (4) SECTOR MOUNTS -INSTALLATION OF (3) SQUIDS -INSTALLATION OF (18) RRHs -INSTALLATION OF 199'-0" MONOPOLE TOWER 199'-0" MONOPOLE TOWER MONOPOLE TOWER MONOPOLE TOWER GROUND SCOPE OF WORK: -INSTALLATION OF H-FRAME -INSTALLATION OF CONCRETE WALK IN CABINET (WIC) -INSTALLATION OF 30KW GENERATOR -INSTALLATION OF (1) CONCRETE PAD -INSTALLATION OF ICE BRIDGE -INSTALLATION OF (2) OUTDOOR RAYCAP DC12s
AutoCAD SHX Text
LTE 1C / 2C / 3C / 4C / 5C / 6C
Page 2: T-1 · 2019-08-07 · project type: new site build general notes driving directions scope of work ... 2595 dallas pkwy frisco, tx 75034 (972) 581-9888. transform your business...through

A&E OFFICE:

2595 DALLAS PKWY FRISCO, TX 75034

(972) 581-9888

TRANSFORM YOUR BUSINESS...THROUGH WIRELESS

PREPARED BY:

CLIENT:

PROFESSIONAL STAMP:

SITE INFORMATION:

DRAWN BY:

CHECKED BY:

SHEET TITLE:

SHEET NUMBER:

DATE:

DATE:

REV DATE DESCRIPTION BY

SUBMITTALS

Mobility

RING NAME:

RING NUMBER:

FA LOCATION CODE:

ADDRESS:

PACE ID:

PROJECTS:

FOR ZONING

··

···

·

ZD-1N

AutoCAD SHX Text
A
AutoCAD SHX Text
05/24/19
AutoCAD SHX Text
FOR REVIEW
AutoCAD SHX Text
RA
AutoCAD SHX Text
B
AutoCAD SHX Text
05/30/19
AutoCAD SHX Text
FOR REVIEW
AutoCAD SHX Text
RA
AutoCAD SHX Text
RA
AutoCAD SHX Text
CD
AutoCAD SHX Text
05/24/19
AutoCAD SHX Text
05/30/19
AutoCAD SHX Text
161 INVERNESS DR W, 2ND FLOOR ENGLEWOOD, COLORADO 80112
AutoCAD SHX Text
NSB-CO.BDN_Add_4591_COL02148
AutoCAD SHX Text
COL02148
AutoCAD SHX Text
12871723
AutoCAD SHX Text
17925 US HWY 24
AutoCAD SHX Text
PEYTON, CO 80831, CO 80831CO 80831 8083180831
AutoCAD SHX Text
MRUTH029076
AutoCAD SHX Text
THIS DOCUMENT IS THE DESIGN PROPERTY AND COPYRIGHT OF NEXIUS AND FOR THE EXCLUSIVE USE BY THE TITLE CLIENT. DUPLICATION OR USE WITHOUT THE EXPRESS WRITTEN CONSENT OF THE CREATOR IS STRICTLY PROHIBITED.
AutoCAD SHX Text
LTE 1C / 2C / 3C / 4C / 5C / 6C
AutoCAD SHX Text
ZONING DOCUMENTS THESE DOCUMENTS ARE RELEASED FOR THE PURPOSE OF ZONING UNDER THE AUTHORITY OF JACK T. PHIPPS ON 05/30/19. 05/30/19. . JACK T. PHIPPS, P.E. COLORADO PROFESSIONAL ENGINEER REGISTRATION NUMBER P-17909 EXPIRATION DATE 10/31/2019 NEXIUS SOLUTION, INC. COLORADO FIRM NO. C-3797 EXPIRATION DATE 08/31/2019
AutoCAD SHX Text
AERIAL MAP
AutoCAD SHX Text
0
AutoCAD SHX Text
300
AutoCAD SHX Text
300
AutoCAD SHX Text
600
AutoCAD SHX Text
1200
AutoCAD SHX Text
GRAPHIC SCALE: 1:300 (IN FEET)
AutoCAD SHX Text
NOTE: THIS PLAN WAS CREATED BASED ON INFORMATION GATHERED FROM AERIAL PHOTOGRAPHY, GIS DATA, AND/OR ASSESSORS MAPS PROVIDED BY LOCAL SOURCES. THIS PLAN IS IN NO WAY INTENDED TO BE USED AS A BOUNDARY SURVEY.
AutoCAD SHX Text
AERIAL MAP
AutoCAD SHX Text
1
AutoCAD SHX Text
SCALE: 1:300
AutoCAD SHX Text
PROPOSED 199'-0" 199'-0" 199'-0" MONOPOLE TOWER
Page 3: T-1 · 2019-08-07 · project type: new site build general notes driving directions scope of work ... 2595 dallas pkwy frisco, tx 75034 (972) 581-9888. transform your business...through

A&E OFFICE:

2595 DALLAS PKWY FRISCO, TX 75034

(972) 581-9888

TRANSFORM YOUR BUSINESS...THROUGH WIRELESS

PREPARED BY:

CLIENT:

PROFESSIONAL STAMP:

SITE INFORMATION:

DRAWN BY:

CHECKED BY:

SHEET TITLE:

SHEET NUMBER:

DATE:

DATE:

REV DATE DESCRIPTION BY

SUBMITTALS

Mobility

RING NAME:

RING NUMBER:

FA LOCATION CODE:

ADDRESS:

PACE ID:

PROJECTS:

FOR ZONING

··

···

·

ZD-2N

AutoCAD SHX Text
PROPOSED 199'-0" 199'-0" 199'-0" MONOPOLE TOWER
AutoCAD SHX Text
PROPOSED CHAIN LINK FENCE
AutoCAD SHX Text
PROPOSED 50'-0" X 50'-0" LEASE AREA
AutoCAD SHX Text
PROPOSED ACCESS GATE
AutoCAD SHX Text
EXISTING LAND
AutoCAD SHX Text
PROPOSED 8'-0" X 8'-0" CONCRETE WIC SHELTER
AutoCAD SHX Text
PROPOSED 12'-0" GRAVEL ROAD FROM COMPOUND TO HWY 24HWY 24
AutoCAD SHX Text
PROPOSED 15'-0" ACCESS AND UTILITY EASEMENT FROM COMPOUND TO HWY 24HWY 24
AutoCAD SHX Text
HWY 24
AutoCAD SHX Text
EXISTING DIRT
AutoCAD SHX Text
ROCK ISLAND TRAIL
AutoCAD SHX Text
PROPOSED GATE FOR NEW ACCESS
AutoCAD SHX Text
EXISTING WOOD FENCE
AutoCAD SHX Text
EXISTING CHAIN LINK FENCE
AutoCAD SHX Text
EXISTING WOOD FENCE
AutoCAD SHX Text
EXISTING DIRT ROAD
AutoCAD SHX Text
EXISTING WOOD POLE
AutoCAD SHX Text
EXISTING LAND
AutoCAD SHX Text
EXISTING LAND
AutoCAD SHX Text
EXISTING LAND
AutoCAD SHX Text
A
AutoCAD SHX Text
05/24/19
AutoCAD SHX Text
FOR REVIEW
AutoCAD SHX Text
RA
AutoCAD SHX Text
B
AutoCAD SHX Text
05/30/19
AutoCAD SHX Text
FOR REVIEW
AutoCAD SHX Text
RA
AutoCAD SHX Text
RA
AutoCAD SHX Text
CD
AutoCAD SHX Text
05/24/19
AutoCAD SHX Text
05/30/19
AutoCAD SHX Text
161 INVERNESS DR W, 2ND FLOOR ENGLEWOOD, COLORADO 80112
AutoCAD SHX Text
NSB-CO.BDN_Add_4591_COL02148
AutoCAD SHX Text
COL02148
AutoCAD SHX Text
12871723
AutoCAD SHX Text
17925 US HWY 24
AutoCAD SHX Text
PEYTON, CO 80831, CO 80831CO 80831 8083180831
AutoCAD SHX Text
MRUTH029076
AutoCAD SHX Text
THIS DOCUMENT IS THE DESIGN PROPERTY AND COPYRIGHT OF NEXIUS AND FOR THE EXCLUSIVE USE BY THE TITLE CLIENT. DUPLICATION OR USE WITHOUT THE EXPRESS WRITTEN CONSENT OF THE CREATOR IS STRICTLY PROHIBITED.
AutoCAD SHX Text
LTE 1C / 2C / 3C / 4C / 5C / 6C
AutoCAD SHX Text
ZONING DOCUMENTS THESE DOCUMENTS ARE RELEASED FOR THE PURPOSE OF ZONING UNDER THE AUTHORITY OF JACK T. PHIPPS ON 05/30/19. 05/30/19. . JACK T. PHIPPS, P.E. COLORADO PROFESSIONAL ENGINEER REGISTRATION NUMBER P-17909 EXPIRATION DATE 10/31/2019 NEXIUS SOLUTION, INC. COLORADO FIRM NO. C-3797 EXPIRATION DATE 08/31/2019
AutoCAD SHX Text
OVERALL SITE PLAN
AutoCAD SHX Text
0
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
100
AutoCAD SHX Text
200
AutoCAD SHX Text
GRAPHIC SCALE: 1:50 (IN FEET)
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
SCALE: 1:50
Page 4: T-1 · 2019-08-07 · project type: new site build general notes driving directions scope of work ... 2595 dallas pkwy frisco, tx 75034 (972) 581-9888. transform your business...through

A&E OFFICE:

2595 DALLAS PKWY FRISCO, TX 75034

(972) 581-9888

TRANSFORM YOUR BUSINESS...THROUGH WIRELESS

PREPARED BY:

CLIENT:

PROFESSIONAL STAMP:

SITE INFORMATION:

DRAWN BY:

CHECKED BY:

SHEET TITLE:

SHEET NUMBER:

DATE:

DATE:

REV DATE DESCRIPTION BY

SUBMITTALS

Mobility

RING NAME:

RING NUMBER:

FA LOCATION CODE:

ADDRESS:

PACE ID:

PROJECTS:

FOR ZONING

··

···

·

ZD-3N

AutoCAD SHX Text
PROPOSED 6' TALL CHAIN LINK FENCE WITH 3 STRANDS OF BARBED WIRE
AutoCAD SHX Text
PROPOSED ACCESS GATE
AutoCAD SHX Text
PROPOSED 30KW GENERATOR
AutoCAD SHX Text
PROPOSED ICE BRIDGE
AutoCAD SHX Text
PROPOSED 199'-0" 199'-0" 199'-0" MONOPOLE TOWER
AutoCAD SHX Text
PROPOSED 8'-0" X 8'-0" CONCRETE WIC SHELTER
AutoCAD SHX Text
PROPOSED 12'-0" GRAVEL ROAD FROM COMPOUND TO HWY 24HWY 24
AutoCAD SHX Text
PROPOSED 15'-0" ACCESS AND UTILITY EASEMENT FROM COMPOUND TO HWY 24HWY 24
AutoCAD SHX Text
PROPOSED SERVICE RACK
AutoCAD SHX Text
INSTALL NEW RAYCAP DC12-48-60-0-25E (TOTAL OF 2)
AutoCAD SHX Text
A
AutoCAD SHX Text
05/24/19
AutoCAD SHX Text
FOR REVIEW
AutoCAD SHX Text
RA
AutoCAD SHX Text
B
AutoCAD SHX Text
05/30/19
AutoCAD SHX Text
FOR REVIEW
AutoCAD SHX Text
RA
AutoCAD SHX Text
RA
AutoCAD SHX Text
CD
AutoCAD SHX Text
05/24/19
AutoCAD SHX Text
05/30/19
AutoCAD SHX Text
161 INVERNESS DR W, 2ND FLOOR ENGLEWOOD, COLORADO 80112
AutoCAD SHX Text
NSB-CO.BDN_Add_4591_COL02148
AutoCAD SHX Text
COL02148
AutoCAD SHX Text
12871723
AutoCAD SHX Text
17925 US HWY 24
AutoCAD SHX Text
PEYTON, CO 80831, CO 80831CO 80831 8083180831
AutoCAD SHX Text
MRUTH029076
AutoCAD SHX Text
THIS DOCUMENT IS THE DESIGN PROPERTY AND COPYRIGHT OF NEXIUS AND FOR THE EXCLUSIVE USE BY THE TITLE CLIENT. DUPLICATION OR USE WITHOUT THE EXPRESS WRITTEN CONSENT OF THE CREATOR IS STRICTLY PROHIBITED.
AutoCAD SHX Text
LTE 1C / 2C / 3C / 4C / 5C / 6C
AutoCAD SHX Text
ZONING DOCUMENTS THESE DOCUMENTS ARE RELEASED FOR THE PURPOSE OF ZONING UNDER THE AUTHORITY OF JACK T. PHIPPS ON 05/30/19. 05/30/19. . JACK T. PHIPPS, P.E. COLORADO PROFESSIONAL ENGINEER REGISTRATION NUMBER P-17909 EXPIRATION DATE 10/31/2019 NEXIUS SOLUTION, INC. COLORADO FIRM NO. C-3797 EXPIRATION DATE 08/31/2019
AutoCAD SHX Text
ENLARGED SITE PLAN
AutoCAD SHX Text
ENLARGED SITE PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text
0
AutoCAD SHX Text
4
AutoCAD SHX Text
8
AutoCAD SHX Text
16
AutoCAD SHX Text
GRAPHIC SCALE: 1/8"=1'-0"
Page 5: T-1 · 2019-08-07 · project type: new site build general notes driving directions scope of work ... 2595 dallas pkwy frisco, tx 75034 (972) 581-9888. transform your business...through

A&E OFFICE:

2595 DALLAS PKWY FRISCO, TX 75034

(972) 581-9888

TRANSFORM YOUR BUSINESS...THROUGH WIRELESS

PREPARED BY:

CLIENT:

PROFESSIONAL STAMP:

SITE INFORMATION:

DRAWN BY:

CHECKED BY:

SHEET TITLE:

SHEET NUMBER:

DATE:

DATE:

REV DATE DESCRIPTION BY

SUBMITTALS

Mobility

RING NAME:

RING NUMBER:

FA LOCATION CODE:

ADDRESS:

PACE ID:

PROJECTS:

FOR ZONING

··

···

·

ZD-4

AutoCAD SHX Text
PROPOSED RRHS (TYP. OF 6 ON ALPHA, BETA AND GAMMA SECTORS, TOTAL OF 18)
AutoCAD SHX Text
PROPOSED SURGE SUPPRESSION DEVICE (TOTAL OF 3)
AutoCAD SHX Text
PROPOSED AT&T ANTENNAS (TYP. OF 4 ON ALPHA, BETA AND GAMMA SECTORS, TOTAL OF 12)
AutoCAD SHX Text
#1
AutoCAD SHX Text
#2
AutoCAD SHX Text
#3
AutoCAD SHX Text
#4
AutoCAD SHX Text
#5
AutoCAD SHX Text
#6
AutoCAD SHX Text
#7
AutoCAD SHX Text
#8
AutoCAD SHX Text
#12
AutoCAD SHX Text
#11
AutoCAD SHX Text
#10
AutoCAD SHX Text
#9
AutoCAD SHX Text
#16
AutoCAD SHX Text
#15
AutoCAD SHX Text
#14
AutoCAD SHX Text
#13
AutoCAD SHX Text
ALPHA SECTOR
AutoCAD SHX Text
AZIMUTH = 30%%D
AutoCAD SHX Text
BETA SECTOR
AutoCAD SHX Text
AZIMUTH = 170%%D
AutoCAD SHX Text
GAMMA SECTOR
AutoCAD SHX Text
AZIMUTH = 280%%D
AutoCAD SHX Text
EXISTING GRADE
AutoCAD SHX Text
ELEV: 0'-0" A.G.L.
AutoCAD SHX Text
PROPOSED 6' TALL CHAIN LINK FENCE WITH 3 STRANDS OF BARBED WIRE
AutoCAD SHX Text
PROPOSED 199'-0" 199'-0" 199'-0" MONOPOLE TOWER
AutoCAD SHX Text
PROPOSED 8'-0" X 8'-0" CONCRETE WIC SHELTER
AutoCAD SHX Text
TOP OF MONOPOLE TOWER
AutoCAD SHX Text
ELEV: 199'-0" A.G.L.
AutoCAD SHX Text
PROPOSED RRHS (TYP. OF 6 ON ALPHA, BETA AND GAMMA SECTORS, TOTAL OF 18)
AutoCAD SHX Text
PROPOSED SURGE SUPPRESSION DEVICE (TOTAL OF 3)
AutoCAD SHX Text
PROPOSED AT&T ANTENNAS (TYP. OF 4 ON ALPHA, BETA AND GAMMA SECTORS, TOTAL OF 12)
AutoCAD SHX Text
FUTURE MICROWAVE DISHES BY OTHERS
AutoCAD SHX Text
PROPOSED ANTENNAS BY FUTURE CARRIERS
AutoCAD SHX Text
TOP OF FUTURE ANTENNAS
AutoCAD SHX Text
ELEV: TBD
AutoCAD SHX Text
TOP OF FUTURE ANTENNAS
AutoCAD SHX Text
ELEV: TBD
AutoCAD SHX Text
TOP OF FUTURE ANTENNAS
AutoCAD SHX Text
ELEV: TBD
AutoCAD SHX Text
C.L OF FUTURE MICROWAVE DISH
AutoCAD SHX Text
ELEV: TBD
AutoCAD SHX Text
C.L OF FUTURE MICROWAVE DISH
AutoCAD SHX Text
ELEV: TBD
AutoCAD SHX Text
TOP OF PROPOSED ANTENNAS
AutoCAD SHX Text
ELEV: 199'-0" A.G.L
AutoCAD SHX Text
A
AutoCAD SHX Text
05/24/19
AutoCAD SHX Text
FOR REVIEW
AutoCAD SHX Text
RA
AutoCAD SHX Text
B
AutoCAD SHX Text
05/30/19
AutoCAD SHX Text
FOR REVIEW
AutoCAD SHX Text
RA
AutoCAD SHX Text
RA
AutoCAD SHX Text
CD
AutoCAD SHX Text
05/24/19
AutoCAD SHX Text
05/30/19
AutoCAD SHX Text
161 INVERNESS DR W, 2ND FLOOR ENGLEWOOD, COLORADO 80112
AutoCAD SHX Text
NSB-CO.BDN_Add_4591_COL02148
AutoCAD SHX Text
COL02148
AutoCAD SHX Text
12871723
AutoCAD SHX Text
17925 US HWY 24
AutoCAD SHX Text
PEYTON, CO 80831, CO 80831CO 80831 8083180831
AutoCAD SHX Text
MRUTH029076
AutoCAD SHX Text
THIS DOCUMENT IS THE DESIGN PROPERTY AND COPYRIGHT OF NEXIUS AND FOR THE EXCLUSIVE USE BY THE TITLE CLIENT. DUPLICATION OR USE WITHOUT THE EXPRESS WRITTEN CONSENT OF THE CREATOR IS STRICTLY PROHIBITED.
AutoCAD SHX Text
LTE 1C / 2C / 3C / 4C / 5C / 6C
AutoCAD SHX Text
ZONING DOCUMENTS THESE DOCUMENTS ARE RELEASED FOR THE PURPOSE OF ZONING UNDER THE AUTHORITY OF JACK T. PHIPPS ON 05/30/19. 05/30/19. . JACK T. PHIPPS, P.E. COLORADO PROFESSIONAL ENGINEER REGISTRATION NUMBER P-17909 EXPIRATION DATE 10/31/2019 NEXIUS SOLUTION, INC. COLORADO FIRM NO. C-3797 EXPIRATION DATE 08/31/2019
AutoCAD SHX Text
PROPOSED TOWER PLAN AND ELEVATION
AutoCAD SHX Text
NOTE: PROJECT OWNER IS RESPONSIBLE FOR PROVIDING A STRUCTURAL STABILITY ANALYSIS TO DETERMINE CAPACITY AND SUITABILITY OF THE EXISTING ANTENNA SUPPORT STRUCTURE AND/OR TOWER STRUCTURE TO SAFELY CARRY ALL ADDITIONAL LOADS IMPOSED BY THE PROPOSED EQUIPMENT AS SHOWN HEREIN. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR INCORPORATING ANY REQUIRED STRUCTURAL MODIFICATIONS INTO THEIR SCOPE OF WORK.
AutoCAD SHX Text
PROPOSED TOWER PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
0
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
8
AutoCAD SHX Text
GRAPHIC SCALE: 1/4"=1'-0"
AutoCAD SHX Text
FOR 11X17 SHEETS
AutoCAD SHX Text
0
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
GRAPHIC SCALE: 1/2"=1'-0"
AutoCAD SHX Text
FOR 22X34 SHEETS
AutoCAD SHX Text
PROPOSED TOWER ELEVATION
AutoCAD SHX Text
2
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"
AutoCAD SHX Text
0
AutoCAD SHX Text
8
AutoCAD SHX Text
16
AutoCAD SHX Text
32
AutoCAD SHX Text
GRAPHIC SCALE: 1/16"=1'-0"
AutoCAD SHX Text
FOR 11X17 SHEETS
AutoCAD SHX Text
0
AutoCAD SHX Text
4
AutoCAD SHX Text
8
AutoCAD SHX Text
16
AutoCAD SHX Text
GRAPHIC SCALE: 1/8"=1'-0"
AutoCAD SHX Text
FOR 22X34 SHEETS
Lindsay Darden
Callout
Label the height of the equipment shelter. They cannot exceed 12' tall.
Lindsay Darden
Text Box
Indicate whether lighting is required by the FAA for this tower and will be provided.