Top Banner
WW meeting 28/11 /01 D. BOUMEDIENE 1 Systematic studies on mw D. BOUMEDIENE – P. PEREZ – E. LANCON CEA/ Saclay O. BUCHMÜLLER 1- Reminder (cone, P cut, PF cut) 2- P Flow cut analysis 3- Cone analysis 4- No typ6 objects analysis 5- Charged only analysis 6- Mjet=0 analysis 7- Conclusion
27

Systematic studies on mw

Jan 13, 2016

Download

Documents

Kamran Qureshi

Systematic studies on mw. D. BOUMEDIENE – P. PEREZ – E. LANCON CEA/ Saclay O. BUCHMÜLLER. 1- Reminder (cone, P cut, PF cut) 2- P Flow cut analysis 3- Cone analysis 4- No typ6 objects analysis 5- Charged only analysis 6- Mjet=0 analysis 7- Conclusion. Reminder. Leukerbad: - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 1

Systematic studies on mwD. BOUMEDIENE – P. PEREZ – E. LANCON

CEA/ Saclay

O. BUCHMÜLLER

1- Reminder (cone, P cut, PF cut)

2- P Flow cut analysis

3- Cone analysis

4- No typ6 objects analysis

5- Charged only analysis

6- Mjet=0 analysis

7- Conclusion

Page 2: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 2

ReminderReminder Leukerbad:

• Pcut analysis (cutting on all Eflow objects) is unstable for all channels

• The instability is due to some neutral objects (ECAL residuals : typ6 Eflow objects )

• the analysis is stable either :

• if typ6 objects are not considered at all,

• or if no cut is applied on typ6 objects

• However the two analyses lead to incompatible mw measurements

Pisa / W meeting 06-07-01:

• Particle Flow based cut analysis is not stable in the 4q channel (it motivated the test of Pcut on 4q and lqq)

Page 3: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 3

AimAim

mw measurement stability is tested for the following algorithms

• Pcut (see Leukerbad meeting)

• PF cut (4q+lqq)

• Cone (4q+lqq)

Absolute ALEPH mw measurement scale is tested with

• Charged only (4q+lqq)

• Typ6 suppression (updated)

• Mjet=0 (4q+lqq) Mw is measured 23 times (4 channels)

New today

Page 4: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 4

TechniquesTechniques 4q channels: 3D fit

lqq channels:

• The lepton is not used (because not concerned by the effect): 2D fit

• All the channels are used (except ll)

Parametrisations/jet corrections are systematically recomputed

Correlations are evaluated at 2 energies (4q+lqq merged)

shifts on mw derived from observed errors.

Page 5: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 5

Pflow Cut AnalysisPflow Cut Analysis PF in 4q channel is given by Thomas's code

An equivalent distribution is defined in the 3 lqq channels

P Flow cut

Page 6: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 6

Pflow cut analysis

Pflow cut analysis

tendency: slope is 2.0 far from 0 (jetset)

discrepancy wrt flat: 1.6

Page 7: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 7

Pflow cut analysis: no cut on typ6 obj.

Pflow cut analysis: no cut on typ6 obj.

tendency: 1.2 from slope=0

discrepancy wrt flat: 0.4

tendency: 2.0 1.2

discrepancy wrt flat:

1.6

Page 8: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 8

PFcut SummaryPFcut Summary• PF cut analysis (cutting on all objects) is unstable (2.0 )

• It is difficult to use it to measure CR

• The size of the effect is compatible with what was observed with the P cut.

-82 51 MeV/c2 (excluding [0.1,0.9], lqq+4q)

• The physical source of the problem in Pcut/Pfcut analyses comes from the same source: cutting on typ6 objects

• PF cut analysis without cutting on typ6 objects is stable

Page 9: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 9

• Hugo’s cone Algorithm is used for the reconstruction (http://alephwww.cern.ch/~ruizh/aleph-only/cones/cones.html)

• jet parametrisations are recomputed

• Jet energy corrections are done ( Patrice talk)

• All energies, all channels (except ll) are used

• Correlations between analyses are computed with

2 x 200k evt (@ 2 energies)

The difference 4q / lqq and energy dependence are neglected

the cone analysisthe cone analysis

Rcone 0.6 0.75 1.0 1.25 2.0

(%) 73 78 83 90 95

Page 10: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 10

Parametrisation (Rc=0.6)

Parametrisation (Rc=0.6)

b: angular resolutio

n

Page 11: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 11

Parametrisation (Rc=2.0)

Parametrisation (Rc=2.0)

b: angular resolutio

n

Page 12: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 12

mw versus RCmw versus RC

tendency: 2.6 far from expectations (jetset)

discrepancy wrt flat: 2.4

Durham analysis (RC=3.0) taken as

reference

better probability for the slope

Page 13: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 13

4q/lqq contributions4q/lqq contributions

Probability of a linear behavior (with a slope) increases when combining 4q and lqq channels

Page 14: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 14

mw versus s (Rc=0.75)

mw versus s (Rc=0.75)

Page 15: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 15

Cone without typ6 objects

Cone without typ6 objects

tendency: FLAT (<1

discrepancy wrt flat: (<1

‘Cutting’ on typ6 objects caused the

instability

RC=2.0 taken as reference

Page 16: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 16

Cone SummaryCone Summary• Cone analysis (with all measured energy) is unstable (2.6 ) as expected

• It cannot be used to measure CR

• The problem is not due to 1 energy only

• The effect is similar to what was observed with the P cut and PF cut analyses :

-85 31 MeV/c2 (Rc=0.6, lqq+4q)

• The physical source of the problem is the same

• Cone analysis without typ6 is stable

Page 17: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 17

Standard Durham analysis without Typ6 objects

Standard Durham analysis without Typ6 objects

• All type6 (~5% energy) objects are removed from the jets.

• Statistical sensitivity loss is < 1% in both lqq and 4q channels

• Correlation with standard analysis =92%

Page 18: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 18

Effect of Typ6 objects suppression

Effect of Typ6 objects suppression

Page 19: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 19

Typ6 Suppression Summary

Typ6 Suppression Summary• mw measured without typ6 objects is

shifted wrt standard analysis by:

-112 20 MeV/c2

• The effect is compatible to what was observed with the P cut / PF cut / cone analyses

Page 20: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 20

Charged only analysis

Charged only analysis

• we can test an analysis using only charged tracks. Such an analysis is reliable (all distributions for charged are in agreement between DATA/MC)

• but we expect a big loss of sensitivity.

Tested analysis: Charged objects only are used

correlation with std analysis: = 31 %

Sensitivity loss: ~ %

Page 21: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 21

Charged only analysisCharged only analysis

Page 22: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 22

Charged Only SummaryCharged Only Summary• mw measured with charged objects only is shifted wrt standard analysis by:

-120 65 MeV/c2

• The effect is compatible to what was observed with the P cut / PF cut / cone / pre typ 6 analyses

Page 23: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 23

• Jet masses are biased by a bad simulation of multiplicities in particular for typ6 objects.

• It is known that the bias propagates to mw

• A measurement with a fixed Mjet should be insensitive to a bias

Tested analysis:

We fix Ejet = Pjet

( same jet mass in MC and DATA)

Nothing is removed, we just forget the jet mass

correlation with std analysis: = 74 %

Sensitivity loss: qlqq %

mjet=0 analysis

mjet=0 analysis

Page 24: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 24

mjet = 0 analysis

mjet = 0 analysis

Page 25: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 25

mjet=0 Summary

mjet=0 Summary

• mw measured with mjet=0 is shifted wrt standard analysis (2D for lqq) by:

-79 31 MeV/c2

• The effect is compatible with what was observed with

P cut / PF cut / cone / pre typ 6 / charged only analyses

Page 26: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 26

CONE (Rc=0.6) - 85 31 (2.7

Pflow - 82 51 (1.6

(exclud. [0.1,0.9])

Pcut (cut 2GeV) -125 40 (3.1) 3.2

Pre TYP6 -112 20 (5.6

Charged only -120 65 (1.8

Mjet=0 - 79 31 (2.5

SummarySummaryAnalysis mw(MeV/c2) slope slope no typ6

we have compelling evidences that the aleph w mass is overestimated by 50-100 MeV/c2

Page 27: Systematic studies on mw

WW meeting 28/11/01 D. BOUMEDIENE 27

ConclusionConclusion

We have compelling evidences that the aleph w mass is overestimated by 50-100 MeV/c2

We have developed low correlated analyses which are stable in the lqq channels (Minimum requirement for 4q Color

Reconnection sensitive analysis)

Those analyses will now be used to study Color Reconnection effect in the 4q channel

mw and width analysis

The code and ntuples are publicly available on

Castor for all energies and all MC