Top Banner
1 | Page System Support: -Up To 9999-Inside Extensions -Up To 4-Extensions Per Room -Up To 6-Building Entrances -Audio-Video Extension Support ‘ZDL-A310C’ Quick Wiring Guide Please Follow Wiring Steps Box Content: - ZDL-A310C [System] - Inside Extensions - Decoder - Connector Cables - Power Supply Box Refer to Steps: 1 Thru. 5 Please Follow Wiring Steps Carefully. ZDL-A75T ZDL-A320C Support Cat5e/6 Cable Or 8-Conductor Cable 1. To Begin: [Before Powering-On] -Wiring utilizing RJ-45 Plug Is Much Quicker: Just Plug RJ45 Behind Door Panel & In To The [In] Of Decoder, And RJ45-Female Ports Of Decoder To Monitors. ***Remove panel rear-cover screws to access connection wire. - If wiring Audio Extension Also [Just Connect Terminated RJ45 Plug To Audio Extension] Installing utilizing 8-wire wiring option: [Big [Middle] plug 6-wire + VI [Brown] & G [Red] wire is all you need to extend to Encoder. Big [Middle] plug 6-wire plus RED & BROWN wire of the 6-wire connector on the right will be required. Big-plug wires connects to IN of Decoder, RED & BROWN wire ties to Decoder Brown [VIN], Red to [VGND]. Note: You Can Daisy-Chain Power Wire From Power Supply To Door Panel And Decoder. Note: Monitors Gets Power From Decoder. See Detailed Wiring Steps Below Required Parts: -Decoder -Power Supply -3-Pin Power/Lock Connector. -3-Pin Decoder Power/Lock Connector. -6-Pin Signal/Panel Add-On Connector Include: Power / Expansion Connector Cable. Please Remove Cover To Connect Power. Note: Decoder Powers Connected Monitors. Include: AC Power Cable. Wire To: L N & Neutral Note: L = Hot / N = GND / Term.3 = Neutral Tie Decoder 2-Power Wire To: 15V/GND. lock Wire To: PUSH Call Residents - Set Admin Unlock Code Set Resident Individual Unlock Code Residents Key-card - Admin Key-card Mail-Man Key-card Buttons:- -Talk -Unlock -Monitor -Ringer -DND -Snap-Shots -Video
8

System Support:Box Content: - ZDL-A310C [System] ‘ZDL ... · - If wiring Audio Extension Also ... Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions

May 14, 2018

Download

Documents

nguyencong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: System Support:Box Content: - ZDL-A310C [System] ‘ZDL ... · - If wiring Audio Extension Also ... Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions

1 | P a g e

System Support: -Up To 9999-Inside Extensions -Up To 4-Extensions Per Room -Up To 6-Building Entrances -Audio-Video Extension Support

‘ZDL-A310C’

Quick Wiring Guide Please Follow Wiring Steps

Box Content: - ZDL-A310C [System] - Inside Extensions - Decoder - Connector Cables - Power Supply Box

Refer to Steps: 1 Thru. 5

Please Follow Wiring Steps Carefully.

ZDL-A75T

ZDL-A320C

Support – Cat5e/6 Cable

Or 8-Conductor Cable

1. To Begin: [Before Powering-On] -Wiring utilizing RJ-45 Plug Is Much Quicker: Just Plug RJ45 Behind Door Panel & In To The [In] Of Decoder, And RJ45-Female Ports Of Decoder To Monitors. ***Remove panel rear-cover screws to access connection wire. - If wiring Audio Extension Also [Just Connect Terminated RJ45 Plug To Audio Extension] Installing utilizing 8-wire wiring option: [Big [Middle] plug 6-wire + VI [Brown] & G [Red] wire is all you need to extend to Encoder. Big [Middle] plug 6-wire plus RED & BROWN wire of the 6-wire connector on the right will be required. Big-plug wires connects to IN of Decoder, RED & BROWN wire ties to Decoder Brown [VIN], Red to [VGND]. Note: You Can Daisy-Chain Power Wire From Power Supply To Door Panel And Decoder. Note: Monitors Gets Power From Decoder. See Detailed Wiring Steps Below

Required Parts: -Decoder -Power Supply -3-Pin Power/Lock Connector. -3-Pin Decoder Power/Lock Connector. -6-Pin Signal/Panel Add-On Connector

Include: Power / Expansion Connector Cable. Please Remove Cover To Connect

Power. Note: Decoder Powers Connected Monitors.

Include: AC Power Cable. Wire To: L N & Neutral Note: L = Hot / N = GND / Term.3 =

Neutral Tie Decoder 2-Power Wire To: 15V/GND. lock Wire To: PUSH

Call Residents - Set Admin Unlock Code

Set Resident Individual Unlock Code

Resident’s Key-card - Admin Key-card

Mail-Man Key-card

Buttons:- -Talk -Unlock -Monitor -Ringer -DND -Snap-Shots -Video

Page 2: System Support:Box Content: - ZDL-A310C [System] ‘ZDL ... · - If wiring Audio Extension Also ... Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions

2 | P a g e

1A. Simple Cat5e/6 With RJ45-Plug Wiring

Cat5E/6 Wiring: Simply attach RJ45-plug to both End Of cable using 568B-Pinout Method [Straight-thru]. Please follow wiring as shown. Terminated Output RJ45-Male Plug connects to Female RJ45-Plug behind Door Station. Connect other end to the IN of DECODER. Decoder OUT is for expansion. Monitors connect to Ports 1 thru 4.

1B. Wiring With 8-Conductor 22-18-16-14 Gauge Cable

8-Wire Option: System support very wide variety of cables. -Cat5E/6 -22-4 Conductor -18-4 Conductor -16-4 Conductor -14-4 Conductor System Includes necessary plugs for this option. Note: RJ45-Plugs not included.

Installing with existing regular 8-conductor wire is easy. Most significant connection is between Door Station and Decoder which can be wired using Cat5e/6 wire. Simply tie the big center connector with 6-wire [Blue, Green, Yellow, Orange, Red, Brown] to Decoder 6-wire with exactly same color scheme. VI & G-Wire of the smaller 6-wire connector will be required as well. Included Power Supply powers both devices. Please refer to the diagram below to see detailed wiring. You have the option to utilize Decoder RJ45-Female Ports or 6-Pin Connector to extend signal to room extensions

Next

Decoder

Next

Decoder

Decoder

Page 3: System Support:Box Content: - ZDL-A310C [System] ‘ZDL ... · - If wiring Audio Extension Also ... Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions

3 | P a g e

2. System Power Wiring –

Please Follow Wiring Procedures Carefully.

1C. Wiring Details 8-Conductor 22-18-16-14 Gauge Cable

ZDL-A310C Decoder

ZDL-A310C Board

ZDL-08037II Power Supply

ZDL-A310C Board

ZDL-A310C Decoder

Use Of Third-Party Power Supply Is Not Recommended.

Page 4: System Support:Box Content: - ZDL-A310C [System] ‘ZDL ... · - If wiring Audio Extension Also ... Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions

4 | P a g e

2a. Electronic Lock Wiring –

Please Follow Wiring Procedures Carefully.

Support: -Battery 15V Backup You Can: -Wire 2-Exit Buttons [Button Wires Same] Adjust Unlock Time: Lock Unlock Time Is Orange Screw Is Located Right Below NC Terminal Of The Power Supply Box. Turn Clock-wise To: Limit Unlock Time Anti-Clock-wise To: Increase Delay Time

3A. Floor/Room Number Assignment – See Diagram Below There is an 8-Pin Jumpers available on each decoder board. [B-A-32-16-8-4-2-1] - Example: Setting Up Floor-1 To 5 [Note: Jumper-1 Is on the right side] [Floor-1: Remove other jumpers except 1 / Floor-2: Remove others and keep 2] Floor-5: Retain jumper 1 & 4, and remove others. Floor-6: Retain jumper 2 & 4 etc. Note: You Must Retain Jumper-B For Setup Above 4-Floors If You Adopt This Format, Your Room/Extension Numbers Shall Be: On the decoder, Port-1 will be Room-101, 2 will be Room-102 etc.. A floor with over 4-Rooms requires 2

nd Decoder. Port-1 [Always on the right]

Will be Room-105, Port-2 Room-106 respectively. [Jumper-A: No Use]

3. Floor/Room Number Setup –

Please Follow Programming Procedures Carefully.

Adjust Lock

Delay Time

Here

Page 5: System Support:Box Content: - ZDL-A310C [System] ‘ZDL ... · - If wiring Audio Extension Also ... Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions

5 | P a g e

3A. Floor/Room Number Setup Cont’d–

Please Follow Programming Procedures Carefully.

Remove Decoder Cover To Locate Jumpers

Room Number Assignment Summary: Example: Application Is For A 6-Storey’s Building With Up To 20-Apartments Per Floor Note: Each decoder accepts 4-monitors, which means 5-decoders will be required for first floor 20-apartments. All 5-decoders setting must be similar to the following image: Room Numbers Will Be-101 Thru 120 Second floor 20-Apartments decoder jumper setting must be similar to the image below: Room Numbers Will Be- 201 Thru 220. Third floor 20-Apartments decoder jumper setting must be similar to the image below: Room Numbers Will Be- 301 Thru 320. Fifth floor 20-Apartments decoder jumper setting must be similar to the image below: Room Numbers Will Be: 501 Thru 520.

Jumper-1

Page 6: System Support:Box Content: - ZDL-A310C [System] ‘ZDL ... · - If wiring Audio Extension Also ... Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions

6 | P a g e

4. Wiring Additional Door Stations – Please Follow Wiring Guide Carefully

Important Notice: System Support Up To 6-Door Station Panels

System support up to 6-Door Stations with unlimited Room Extension. Door Panel-1 monitors other connected Door Panels. Meaning, information programmed in Door Panel-1 automatically updates all attached Door Panels in the chain. Decoder decides how call is routed.

Important Tips!!!!

Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions + 1-Electronic Lock. Extra power supply box will be required for each Door Station especially if Electronic Lock is needed. If installing over 4-extensions, Decoder Power + lock wires can be daisy-chained from decoder to decoder.

Note: Use Of Third-Party Power Supply Is Not Recommended.

Page 7: System Support:Box Content: - ZDL-A310C [System] ‘ZDL ... · - If wiring Audio Extension Also ... Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions

7 | P a g e

2-Methods Of Programming Smart Key-Cards/Fey-Fobs - Method-1 [Very Quick]

System comes included with 2-Programming Cards [Add & Delete Cards]. You can add multiple by simply showing ADD Card to the inductive area of the Door Station painted black [Card Reader]. Reader should beep once, meaning: [Programming Mode]. You must begin showing your new cards To the reader one at a time within 3-Seconds of hearing that single beep, or else reader will time-out. To Delete: Just swipe DELETE Card on the Reader to Delete/Purge all Key-Card records [Note: Each Card Has Unique 10-Digit Number Of Its Own, Use This Number To Create Issuing Records]

- Method-2 [Use Of Remote Control] This method allows you to key-in actual card number with future possibility of selecting it for deletion. To begin, key-in 1234 + F2 to access system [1234 Is Remote Control System Access Code]. Then key-in [0] to add a Key-Card/Key-Fob, green light shows up immediately. Now, enter Key-Card/Key-Fobs 10-digit Number [Each Key-Card/Key-Fob Has Own Unique Number] + F2. [Note: F2 Confirms Your Selection *Multiple key-Card Addition With Remote Key-in 1234 +F2, and key-in 1 to add multiple key-Cards. Green light shows up, then you can swipe card on the reader one at a time. *To Select A Specific Key-Card For Deletion Key-in 1234 +F2, and key-in 2 + 10-Digit Key-Card Number To Be Deleted + F2 to confirm. *Deleting Multiple Key-Cards Key-in 1234 + F2, and key-in 3 to get green light. Then swipe key-cards one at a time. *Delete All Key-Card Records Key-in 1234 +F2, and key-in 4 + F2. Short beep indicates all key-cards deleted. Remote Control Other Functions Remote Control Code-5: Passage Mode [Keeps Attached Electronic Lock Open] 1234 + F2, then 5 + F2. Remote Control Code-6: Locked Mode [Keep Attached Electronic Lock Locked] 1234 + F2, then 6 + F2. Remote Control Code-7: Instant Unlock [Key-in code To Unlock & Auto Lock] 1234 + F2, then 7 + F2 Remote Control Code-8: Change Remote Control Code – 1234 + F2, then 8 + F2 [Code Must Be 4-Digit]

Important!!!!

We Suggest You Keep Factory Remote Control Code & System Access Code To Prevent From Having To Reset All Devices Back To Factory Default.

5. Residents Key-Cards/Key-Fobs/Key-Code Assignment – Please Follow

Wiring Guide Carefully Important Notice: System Support Up To 6-Door Station Panels

Key-Cards/Key-Fobs Programming

Page 8: System Support:Box Content: - ZDL-A310C [System] ‘ZDL ... · - If wiring Audio Extension Also ... Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions

8 | P a g e

Setting Resident’s Door Access Codes: Factory System Default Password: 20021268

Setting up door access code for the first resident, enter [**] on the Door Panel Keypad. System should

display 1234, and then enter System Default Password: 20021268. 1- - 7 should display on the screen, now enter [3] to display 4-digit blank form [----] [Floor & Room Number]. Key-in 2-digit floor number and

2-digit room number. Should automatically switch screen to display [NE1] and instantly switch to blank

form [----] [4-Digit Blank Form] to request new unlock code.

Key-in new 4-Digit Unlock Code, and [NE2] will show up then display another 4-digit blank form. Key-in

4-Digit Unlock Code again to confirm. “GOOD” [Meaning: New Unlock Code Programming Is Successful] should display immediately if unlock code matches. Repeat same steps for all residents..

Unlocking With New Programmed Code:

Press the [*] key and enter 4-digit Floor & Room Number, then press [#] to confirm. Enter 4-digit

Code and press [#] to unlock. Example: Unlocking With Floor-01 Apartment-01 Tenant Unlock

Code- [*] + 0101 + [#] + [Unlock Code] 2134 + [#] To Unlock.

Note: System Does Not Support Name List Directory.

5A. Resident’s Private Access Key-Code

Programming System Default Password: 20021268

For Further Assistance Please Contact:

[email protected]