Breakers and Switches

Switch fusesOS and OSM

Page 2: Switch fuses OS and OSM - ABB
Page 3: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Contents 3

Switch fuses OS and OSM 20...1250

Product overview, features

Product overview 4

Features 6

Technical data 7

Type designation key 17

Ordering information, manual operation, DIN type 19

Front operated 19

Side operated 24

Special connected 26

Ordering information, manual operation, BS type 28

Front operated 28

Side operated 34

Special connected 36

Ordering information, manual operation, NFC type 38

Front operated 38

Side operated 39

Ordering information, manual operation, CC, J and L types 40

Front operated 40

Side operated 42

Ordering information, motorized operation 43

Motorized switch fuses OSM, DIN-, BS- and NFC -types 43

Ordering information, accessories 45

Selection overview 45

Optional handles 47

Extended shafts and shaft accessories 51

Auxiliary contacts 54

Fourth poles and neutral links 57

Solid links, handle/fuse storage and phase barriers 59

Terminal shrouds and terminal angles 60

Terminal clamps 62

Conversion kits 65

Blown fuse indicators 68

Locking and mounting accessories 69

Dimension drawings 71

Contact functions 105

Index 107

Page 4: Switch fuses OS and OSM - ABB

4 Product overview | Switch fuses OS and OSM

Switch fuses 20...1250 Amperes

Manual operation

Switch size [A] 20 25 30 32 35 40 32 50 60 63 100 125 160 100 200 250

DIN - OS40FD OS32GD OS125GD OS200D

- OS63GD OS160GD OS250D

BS OS20FB OS32GB OS100GB OS200B

OS32FB OS63GB OS125GB OS250B

OS160GB

NFC OS25FF OS50GF OS125GF

OS32FF

UL98 File # E101914 OS30FACC OS60GJ OS100GJ

OS30FAJ

AC23/400 V [kW] 11 15 15 18.5 15 22 30 55 75 110 140

AC23/415 V [kW] 7.5 15 15 30 55 55 75 110 145

480 V [HP] 15 30 60

600 V [HP] 20 50 75

Switch size [A] 200 315 400 600 630 800 1200 1250

DIN OS400D OS630D OS1250D

OS800D

BS OS315B OS630B OS1250B

OS400B OS800B

UL98 File # E101914 OS200J OS400J OS600J OS1200L

OS800L

AC23/400 V [kW] 230 355 450 560

AC23/415 V [kW] 180 230 355 450 560

480 V [HP] 150 250 400 500 -

600 V [HP] 200 250 500 600 -

Page 5: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Product overview 5

Switch fuses 20...1250 Amperes

Motor operation

Switch size [A] 32 50 63 100 125 160 200 250

DIN OSM32GD OSM125GD OSM200D

OSM63GD OSM160GD OSM250D

BS OSM32GB OSM100GB OSM200B

OSM63GB OSM125GB OSM250B

OSM160GB

Switch size [A] 315 400 630 800 1250

DIN OSM400D OSM630D OSM1250D

OSM800D

BS OSM315B OSM630B OSM1250B

OSM400B OSM800B

Page 6: Switch fuses OS and OSM - ABB

6 Features | Switch fuses OS and OSM

Switch fusesDesigned for extreme conditions

Reduced testing and design costsTested type 2 co-ordination tables for motor protection are available. This enables a fast and easy selection of motor control devices. (http://applications.it.abb.com/SOC/Page/Selection.aspx)

Easy installation and design of panelsThanks to a modular structure the mechanism and poles can be placed according to installation requirements. The shaft is adjustable for a range of installation depths.

Save money and installation spaceOS switch fuses are compact, allowing installation in smaller enclosures. Lighweight structure saves money by reducing installation time.

High protection and reliabilityContact design enables rapid fault clearance and maintains protection level even after fault occurs.

Page 7: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Technical data 7

Technical data according to IEC 60947-3 OS (Mini) OS (Mini) OS (Mini) OS (Mini) OS_Switch size A 20 25 32 40 32G

Rated insulation voltage Pollution degree 3 V 1 000 1 000 1 000 1 000 1 000Dielectric strength 50 Hz 1min. kV 10 10 10 10 10Rated impulse withstand voltage kV 12 12 12 12 12Rated thermal current in ambient In open air A/W 20/3.5 25/3.5 32/3.5 40/4.5 32/7.535 °C and temporarily 40 °C4) / In enclosure2) A/W 20/3.5 25/3.5 32/3.5 40/4.5 32/7.5max. fuse power dissipation1) In enclosure with solid links A 32 32 32 40...with minimum cable cross section Cu mm2 2.5 4 6 10 6Rated operational voltage AC-20 and DC-20 V 1 000 1 000 1 000 1 000 1 000Rated operational current, AC-21A up to 500 V A 20 25 32 40 32

690 V A 20 25 32 40 32Rated operational current, AC-22A up to 500 V A 20 25 32 40 32

690 V A 20 25 32 40 32Rated operational current, AC-23A up to 500 V A 20 25 32 40 32

690 V A 20 25 32 40 32Rated operational current / poles in series DC-21A 48 V A 20/2 25/2 32/2 32/2 32/2

110-220 V A 20/2 25/2 32/2 32/2 32/2*440 V A 20/4 25/4 25/4 32/4 32/4*

Rated operational current / poles in series DC-22A 48 V A 20/2 25/2 32/2 32/2 32/2110-220 V A 20/2 25/2 32/2 32/2 32/2*440 V A 20/4 25/4 32/4 32/4

Rated operational current / poles in series DC-23A 48 V A 20/2 25/2 32/2 32/2 32/2 110-220 V A 20/2 25/2 32/2 32/2 32/2*

440 V A 20/4 25/4 32/4 32/4Rated operational power, AC-233) The kW-ratings are accurate for 230 V kW 5.5 5.5 7.5 11 7.5

three-phase 1500 R.P.M. 400 V kW 7.5 11 15 18.5 15standard asynchronous motors. 415 V kW 7.5 11 15 18.5 15

500 V kW 11 15 18.5 22 18.5690 V kW 15 22 22 30 22

Rated breaking capacity in category AC-23 ≤ 690 V A 256 256 256 320 504Rated breaking capacity / poles in series up to 220 V A 128/2 128/2 128/2 128/2 252/2in category DC-23 440 V A 128/4 128/4 128/4 128/4Rated conditional short-circuit current at prospective SC-current 80 kA, 415 V kA 9 9 9 9 13.5Ip (r.m.s.) and corresponding max. Max. OFA_ fuse size gG / aM A 80/63allowed cut-off current îc at prospective SC-current 100 kA, 500 V kA 8 8 8 8 12.5 Max. OFA_ fuse size gG / aM A 63/50The cut-off current îc refers to values at prospective SC-current 50 kA, 690 V kA 7 7 7 7 9.5listed by fuse manufacturers Max. OFA_ fuse size gG / aM A 63/50(single phase test acc. to IEC60269). at prospective SC-current 80 kA, 690 V kA 7.5 7.5 7.5 7.5 11.5

Max. OFA_ fuse size gG / aM A 50/50Rated short-time withstand current, 1 s. r.m.s. -value kA 1 1 1 1 2.5Rated capacitor power The capacitor rating of the 400 V kVAr 10 12.5 15 15 15when no initial charge on the capacitor switch-fuse is limited by 415 V kVAr 10 12 15 15 15

the fuse link. 690 V kVAr 15 20 25 25 25Power loss / pole With rated current, without fuse W 1.3 1.3 2 3.5 1Mechanical endurance Divide by two for operation cycles Oper. 20 000 20 000 20 000 20 000 20 000Fuse types, IEC 60269-2-1 DIN 43620 000 000

NFC 63210, 63211 10x38 14x51BS 88-2, -6 -size / A1 A1, A2 A2-A35)

distance of fuse-link bolts mm M4/44.5 M4/44.5 (A1) M5/73mm M4/73 (A2)

Cable size Cu mm2 0.75...10 0.75...10 0.75...10 0.75...10 2.5...25Terminal tightening torque Counter torque required Nm 2 2 2 2 3/46)

Fuse-links bolts tightening torque Nm 2 2 3.5Operating torque Typical for 3-pole switch fuses Nm 3 3 3 3 5

Technical data, IECSwitch fuses OS20...40 and OS32G

* = Utilization category B 1) Ambient temperature 60°C: derating 20%. Mounting on "ceiling": derating 10% 2) OS160G: Mounting on wall, horizontal fuses: derating 5% 3) Some fuse links limit these figures further. Starting current characteristics must be considered separately 4) Acc. to IEC 60947-1, § 6.1.1. Minimum ambient temperature -5°C. Category B: -5°C...-35°C 5) Max. fuse body diam. 22 mm 6) 3 Nm with cable sizes 2.5...6 mm2, 4 Nm with cable sizes 10...25 mm2

Page 8: Switch fuses OS and OSM - ABB

8 Technical data | Switch fuses OS and OSM

Technical data, IECSwitch fuses OS50...160G

Technical data according to IEC 60947-3 OS_ OS_ OS_ OS_ OS_Switch size A 50G 63G 100G 125G 160G

Rated insulation voltage Pollution degree 3 V 1 000 1 000 1 000 1 000 1 000Dielectric strength 50 Hz 1min. kV 10 10 10 10 10Rated impulse withstand voltage kV 12 12 8 8 8Rated thermal current in ambient In open air A/W 50/7.5 63/7.5 100/12 125/12 160/1235 °C and temporarily 40 °C5) / In enclosure2) A/W 50/7.5 63/7.5 100/12 125/12 160/12max. fuse power dissipation1)

...with minimum cable cross section Cu mm2 10 16 50 50 70Rated operational voltage AC-20 and DC-20 V 1 000 1 000 1 000 1 000 1 000Rated operational current, AC-21A up to 500 V A 50 63 100 125 160

690 V A 50 63 100 125 160Rated operational current, AC-22A up to 500 V A 50 63 100 125 160

690 V A 50 63 100 125 160Rated operational current, AC-23A up to 500 V A 50 63 100 125 160

690 V A 50 63 100 125 160Rated operational current / poles in series DC-21A 48 V A 50/2 63/2 100/2 125/2 160/2

110-220 V A 50/2* 63/2* 100/2* 125/2* 125/2*440 V A 50/4* 50/4* 100/4* 125/4* 125/4*

Rated operational current / poles in series DC-22A 48 V A 50/2 63/2 100/2 125/2 160/2110-220 V A 50/2* 63/2* 100/2* 125/2* 125/2*

Rated operational current / poles in series DC-23A 48 V A 50/2 63/2 100/2 125/2 160/2 110-220 V A 50/2* 63/2* 100/2* 125/2* 125/2*Rated operational power, AC-234) The kW-ratings are accurate for 230 V kW 11 18.5 30 37 45

three-phase 1500 R.P.M. 400 V kW 22 30 55 55 75standard asynchronous motors. 415 V kW 22 30 55 55 75

500 V kW 30 37 55 75 90690 V kW 37 55 90 110 132

Rated breaking capacity in category AC-23 ≤ 690 V A 504 504 1280 1280 1280Rated breaking capacity / poles in series up to 220 V A 252/2 252/2 640/2 640/2 640/2in category DC-23Rated conditional short-circuit current at prospective SC-current 80 kA, 415 V kA 13.5 13.5 23.5 23.5 23.5Ip (r.m.s.) and corresponding max. Max. OFA_ fuse size gG / aM A 80/63 80/63 160/160 160/160 160/160allowed cut-off current îc at prospective SC-current 100 kA, 500 V kA 12.5 12.5 25.5 25.5 25.5 Max. OFA_ fuse size gG / aM A 63/50 63/50 160/160 160/160 160/160The cut-off current îc refers to values at prospective SC-current 50 kA, 690 V kA 9.5 9.5 17.5 17.5 17.5listed by fuse manufacturers Max. OFA_ fuse size gG / aM A 63/50 63/50 125/160 125/160 125/160(single phase test acc. to IEC60269). at prospective SC-current 80 kA, 690 V kA 11.5 11.5 20.5 20.5 20.5

Max. OFA_ fuse size gG / aM A 50/50 50/50 125/160 125/160 125/160Rated short-time withstand current, 1 s. r.m.s. -value kA 2.5 2.5 5 5 5Rated capacitor power The capacitor rating of the 400 V kVAr 20 25 40 50 60when no initial charge on the capacitor switch-fuse is limited by 415 V kVAr 25 32 42 55 65

the fuse link. 690 V kVAr 42 50 75 90 100Power loss / pole With rated current, without fuse W 2.5 4 4 5 9Mechanical endurance Divide by two for operation cycles Oper. 20 000 20 000 20 000 16 000 16 000Fuse types, IEC 60269-2-1 DIN 43620 000 000, 00 000, 00

NFC 63210, 63211 14x51 22x58BS 88-2, -6 -size / A2-A36) A2-A43) A2-A43) A2-A43)

distance of fuse-link bolts mm M5/73 M5/73, M8/94 M5/73, M8/94 M5/73, M8/94mm

Cable size Cu mm2 2.5...25 2.5...25 Terminal tightening torque Counter torque required Nm 3/47) 3/47) 15-22 15-22 15-22Fuse-links bolts tightening torque Nm 3.5 M5:3.5 M8:5 M5:3.5 M8:5 M5:3.5 M8:5Operating torque Typical for 3-pole switch fuses Nm 5 5 7 7 7

* = Utilization category B 1) Ambient temperature 60°C: derating 20%. Mounting on "ceiling": derating 10% 2) OS160G: Mounting on wall, horizontal fuses: derating 5% 3) Max. fuse body diam. 32 mm 4) Some fuse links limit these figures further. Starting current characteristics must be considered separately 5) Acc. to IEC 60947-1, § 6.1.1. Minimum ambient temperature -5°C. Category B: -5°C...-35°C 6) Max. fuse body diam. 22 mm 7) 3 Nm with cable sizes 2.5...6 mm2, 4 Nm with cable sizes 10...25 mm2

Page 9: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Technical data 9

Technical data, IECSwitch fuses OS/OSM200...1250

Technical data according to IEC 60947-3 OS_ OS_ OS_ OS_ OS_Switch size A 200GB 200_ 250_ 315_ 400_

Rated insulation voltage and rated operationalvoltage AC-20 and DC-20 Pollution degree 3 V 1 000 1000 1 000 1 000 1 000Dielectric strength 50 Hz 1min. kV 10 10 10 10 10Rated impulse withstand voltage kV 8 12 12 12 12Rated thermal current in ambient 35 °C and temporarily 40 °C5) / In open air A/W 200/14 200/17 250/23 315/32 400/45max. fuse power dissipation In enclosure A/W 200/14 200/15 250/20 315/32 400/30...with minimum cable cross section Cu mm2 70 95 120 185 240Derating, mounting on In open air or ventilated enclosure % 0 0 0 0 4wall horizontal fuses Totally enclosed % 5 5 5 5 8Derating, mounting on ceiling % 10 10 10 10 10Derating at 60 °C In open air / in enclosure % 20/20 20/20 20/20 20/20 20/20Rated operational current AC-22B ≤ 415 V A 200Rated operational current AC-21A ≤ 500 V A 160 200 250 315 400

690 V A 160 200 250 315 400Rated operational current AC-22A ≤ 415 V A 160 200 250 315 400

500 V A 160 200 250 315 400690 V A 160 200 250 315 400

Rated operational current AC-23A ≤ 415 V A 160 200 250 315 400500 V A 160 200 250 315 400690 V A 160 200 250 315 400

Rated operational current / ≤ 220 V A 125/26) 200/1 250/1 315/2 400/2poles in series DC-21A, DC-22A and DC-23A 440 V A 125/46) 200/2 250/2 315/34) 400/34)

660 V A 200/3 250/3 315/44) 400/44)

750 V A 180/4 230/4 315/44) 400/44)

880 V A 180/4 230/4Rated operational power AC-231) 230 V kW 45 60 75 100 132

400 V kW 75 110 140 160 220415 V kW 75 110 145 180 230500 V kW 90 132 170 220 280690 V kW 132 200 250 315 400

Rated breaking capacity AC-23 ≤ 690 V A 1280 1600 2000 3200 3200Rated conditional short-circuit at prospective SC-current 80 kA, 415 V kA 23.5 35 40.5 59current Ip (r.m.s.) Max. OFA_ fuse size gG/aM A 160/160 250/200 355/315 500/500and corresponding max. at prospective SC-current 100 kA, 500 V kA 25.5 37.5 37.5 63.5allowed cut-off current îc Max. OFA_ fuse size gG/aM A 160/160 250/200 250/250 500/500

at prospective SC-current 80 kA, 690 V kA 20.5 25 32.5 46Max. OFA_ fuse size gG/aM A 125/160 160/ 200/250 315/400

The cut-off current îc refers at prospective SC-current 50 kA, 415 V kA 17.5 28 28 44 44to values listed by fuse Max. BS fuse size gG/gM A 125/160 200/200M315 250/200M315 400/400M500 400/400M500manufacturers (single phase at prospective SC-current 80 kA, 690 V kA 20.5 28 28 48 48test acc. to IEC60269). Max. BS fuse size gG/gM A 125/160 200/200M250 250/200M250 400/400M450 400/400M450Rated short-time withstand current, 1s. r.m.s. -value kA 5 8 8 14 14

Max. distance from switch frame mm 150 150 150 150 150to nearest busbar/cable support

Rated capacitor power The capacitor ratings of the switch-fuses 400 V kVAr 60 90 105 145 180when no initial charge of the capacitor are limited by the fuse links 415 V kVAr 65 100 115 160 200

500 V kVAr 120 135 175 215690 V kVAr 100 160 190 250 325

Power loss / pole With rated current, without fuse W 9 8 13 19 30Mechanical endurance Divide by two for operation cycles Oper. 16 000 20 000 20 000 16 000 16 000Fuse types, IEC 60269-2 Sec. I, DIN 43620 0 0-1 0-2

Sec. IA, NFC 0-3 Ref.A, 4a Ref.B 1 1 2Sec. II, BS 88 A2-A4 B1-B2 B1-B32) B1-B43) B1-B43)

Size / distance of fuse-link bolts mm M5/73, M8/94 M6/111 M8/111 M8/111 M8/111Terminal tightening torque Counter torque required Nm 15-22 15-22 30-44 30-44 30-44Fuse-links bolts tightening torque Nm M5:3.5 M8:5 4 5 20 20Operating torque Typical for 3-pole switch fuses Nm 7 7 7 19 19

1) These values are given for guidance and may vary acc. to the motor manufacturer2) Max fuse body dia 52 mm3) Max fuse body dia 62 mm 4) Category B 5) Acc. to IEC 60957-2, IEC 60947-1, § 6.1.1. Minimum ambient temperature -5°C. Category B: -5°C...-35°C 6) Utilization category DC21-B

Page 10: Switch fuses OS and OSM - ABB

10 Technical data | Switch fuses OS and OSM

Technical data according to IEC 60947-3 OS_ OS_ OS_Switch size A 630_ 800_ 1250_

Rated insulation voltage and rated operationalvoltage AC-20 and DC-20 Pollution degree 3 V 1000 1000 1000Dielectric strength 50 Hz 1min. kV 10 10 10Rated impulse withstand voltage kV 12 12 12Rated thermal current in ambient 35 °C and temporarily in 40 °C3) / In open air A/W 630/60 800/65 1250/110max. fuse power dissipation In enclosure A/W 570/50 720/55 1000/85...with minimum cable cross section Cu mm2 2 x 185 2 x 240 2 x 400Derating, mounting on In open air or ventilated enclosure % 0 4 4wall horizontal fuses Totally enclosed % 5 8 8Derating, mounting on 'ceiling' % 10 10 10Derating at 60 °C In open air / in enclosure % 20/20 20/20 20/20Rated operational current AC-21A ≤ 500 V A 630 800 12504)

690 V A 630 800 12504)

Rated operational current AC-22A ≤ 415 V A 630 800 1250500 V A 630 800 12504)

690 V A 630 800 12504)

Rated operational current AC-23A ≤ 415 V A 6302) 800 1000500 V A 6302) 800 10004)

690 V A 6302) 800 10004)

Rated operational current / ≤ 220 V A 630/12) 800/12)

poles in series DC-21A, DC-22A and DC-23A 440 V A 630/22) 800/22)

660 V A 630/32) 720/32)

750 V A 630/42) 720/42)

880 V A 630/42) 720/42)

Rated operational power AC-231) 230 V kW 200 250 315400 V kW 355 450 560415 V kW 355 450 560500 V kW 450 560 710690 V kW 630 710 1000

Rated breaking capacity AC-23 ≤ 690 V A 6400 6400 8000Rated conditional short circuit current at prospective SC-current 80 kA, 415 V kA 77 77 89 Ip (r.m.s.) and corresponding max. Max. OFA_ fuse size gG/aM A 800/800 800/800 1250/1250 allowed cut-off current îc at prospective SC-current 100 kA, 500 V kA 83 83 105

Max. OFA_ fuse size gG/aM A 800/800 800/800 1250/-The cut-off current îc refers to values at prospective SC-current 80 kA, 690 V kA 55 55 88listed by fuse manufacturers Max. OFA_ fuse size gG/aM A 500/630 500/630 1000/1000(single phase at prospective SC-current 50 kA, 415 V kA 67 67 90test acc. to IEC60269) Max. BS fuse size gG/gM ARated short-time withstand current, 1s. r.m.s. -value kA 18 18 40

Max. distance from switch frame mm 150 150 150to nearest busbar/cable support

Rated capacitor power The capacitor ratings of the 400 V kVAr 250 310 440when no initial charge of the capacitor switch-fuses are limited by 415 V kVAr 270 340 460

the fuse links 500 V kVAr 300 375 550690 V kVAr 450 550 750

Power loss / pole With rated current, without fuse W 46 75 75Mechanical endurance Divide by two for operation cycles Oper. 10 000 6000 6000Fuse types, IEC 60269-2 Sec. I, DIN 43620 3 3 4, 4 a

Sec. IA, NFC 0-3 Ref.A, 4a Ref.B 3 3 4 aSec. II, BS 88 C1-C2 C1-C3 D1Size / distance of fuse-link bolts mm M10/133, 184 M10/133, 184 2xM12/149

Terminal tightening torque Counter torque required Nm 50-75 50-75 50-75Fuse-links bolts tightening torque Nm M10:30 M12:40 M10:30 M12:40 M12:40Operating torque Typical for 3-pole switch fuses Nm 38 38 65

1) These values are given for guidance and may vary acc. to the motor manufacturer2) Category B with 4-pole3) Acc. to IEC 60957-2, IEC 60947-1, § 6.1.1. Minimum ambient temperature -5°C. Category B: -5°C...-35°C

Technical data, IECSwitch fuses OS/OSM200...1250

Page 11: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Technical data 11

Technical data, IECSpecial connected switch fuses OS125...200

Technical data according to IEC 60947-3 OS OS OS

Switch size A 125G 160G 200

Rated insulation voltage and rated operational voltage AC-20 and DC-20 Pollution degree 3 V 1000 1000 1000Dielectric strength 50 Hz 1min. kV 10 10 10Rated impulse withstand voltage kV 8 8 12Rated thermal current in ambient 35 °C A/W 125/12 160/12 200/17and temporarily 40 °C10)/max. fuse power dissipation1)

...with minimum cable or bar cross section Cu mm² 50 70 95Rated operational current, AC-21A, AC-22A, AC-23A up to 690 V A 125 160 200Rated operational current/poles in series 48 V A 125/2 160/2 200/1

DC-21A, DC-22A and DC23-A 110-220 V A 125/2 125/2* 200/1440 V A 125/4*(DC-21A) 125/4*(DC-21A) 200/2660 V A 200/3750 V A 180/4 880 V A 180/4

Rated operational power, AC-232) The kW-ratings are accurate for 230 V kW 37 45 60three-phase 1500 R.P.M. standard 400 V/415 V kW 55/55 75/75 100/110asynchronous motors. 500 V/690 V kW 75/110 90/132 140/180

Rated breaking capacity in category AC-23 up to 690 V A 1280 1280 1600Rated breaking capacity/poles in series in category DC-23 up to 220 V A 640/2 640/2Rated conditional short-circuit current Ip (r.m.s.) at prospective SC-current 80 kA, 415 V kA 23.5 23.5and corresponding max. allowed cut-off current îc Max. OFA_ fuse size gG/aM A 160/160 160/160The cut-off currents îc refer to values listed by at prospective SC-current 100 kA, 500 V kA 25.5 25.5 30fuse manufacturers7) Max. OFA_ fuse size gG/aM A 160/160 160/160 200/2008)

(single phase test acc. to IEC60269) at prospective SC-current 50 kA, 690 V kA 17.5 17.5 20Max. OFA_ fuse size gG/aM A 125/160 125/160 160/-at prospective SC-current 80 kA, 690 V kA 20.5 20.5 25Max. OFA_ fuse size gG/aM A 125/160 125/160 160/-8)

Rated short-time withstand current, 1s. r.m.s. -value kA 5 5 8Max. distance from switch frame mm 150to nearest busbar/cable support

Rated capacitor power The capacitor rating of the switch- 400 V/415 V kVAr 50/55 60/65when there is no initial charge on the capacitor fuse is limited by the fuse link 690 V kVAr 90 100Power loss/pole With rated current, without fuse BB, BD, UB W 5 9 8

P_, L_, _R, _L, LR W 11Mechanical endurance Divide by two for operation cycles Oper. 20 000 20 000 20 000Fuse types, IEC 60269-2 DIN 43620 BB, BD, UB 000, 00 000, 00 0

P_, L_, _R, _L, LR 000, 00 000, 00BS 88 BB, BD, UB A2-A49) A2-A49) B1 - B24)

-size/distance of fuse-link bolts BB, BD, UB mm M5/73, M8/94 M5/73, M8/94 M6/111BS 88 P_, L_, _R, _L, LR A2-A49) A2-A49) B1 - B34)

-size/distance of fuse-link bolts P_, L_, _R, _L, LR mm M5/73, M8/94 M5/73, M8/94 M8/111Terminal tightening torque Counter torque required Nm 15-22 15-22 M8:15-225),M10:30-44Fuse-links bolts tightening torque BB, BD, UB Nm M5:3.5 M8:5 M5:3.5 M8:5 4

P_, L_, _R, _L, LR Nm 5Operating torque Typical for 3 and 4-pole switches Nm 7 7 7

* B category.1) Ambient temperature 60 °C: derating 20%; mounting on ceiling: derating 10%; mounting on wall, horizontal fuses: derating 8%.

OS160G: Mounting on wall, horizontal fuses: derating 5%.2) Some fuse links limit these figures further. Starting current characteristics must be considered separately. 3) Max fuse body dia 52 mm. 4) Side terminals tightening torque max 15 Nm.

5) BS fuse manufacturers covered by this table ABB, MEM, Bussmann, GEC.6) 3-pole types only. 7) Max fuse body dia 32 mm. 8) Acc. to IEC 60947-1, § 6.1.1. Minimum ambient temperature -5°C.Category B: -5°C...-35°C.

Page 12: Switch fuses OS and OSM - ABB

12 Technical data | Switch fuses OS and OSM

Technical data, IECSpecial connected switch fuses OS250...400

Technical data according to IEC 60947-3 OS OS OS

Switch size A 250 315 400

Rated insulation voltage and rated operational voltage AC-20 and DC-20 Pollution degree 3 V 1 000 1 000 1 000Dielectric strength 50 Hz 1min. kV 10 10 10Rated impulse withstand voltage kV 12 12 12Rated thermal current in ambient 35°C and temporarily 40°C9)/max. fuse power dissipation1) A/W 250/23 315/32 400/45...with minimum cable or bar cross section Cu mm² 120 185 240Rated operational current, AC-21A, AC-22A, AC-23A up to 690 V A 250 315 400Rated operational current/poles in series 48 V A 250/1 315/2 400/2DC-21A, DC-22A and DC23-A 110-220 V A 250/1 315/2 400/2

440 V A 250/2 315/3* 400/3*660 V A 250/3 315/4* 400/4*750 V A 230/4 315/4* 400/4* 880 V A 230/4

Rated operational power, AC-232) The kW-ratings are accurate for 230 V kW 75 100 110three-phase 1500 R.P.M. standard 400 V/415 V kW 132/140 170/180 220/230asynchronous motors. 500 V/690 V kW 170/240 220/295 280/355

Rated breaking capacity in category AC-23 up to 690 V A 2000 3200 3200Rated conditional short-circuit current Ip (r.m.s.) at prospective SC-current 65 kA, 500 V kA 32,5 40.5and corresponding max. allowed Max. OFA_ fuse size gG/aM A 250/- 400/-cut-off current îc

The cut-off currents îc refer to values listed by at prospective SC-current 100 kA, 500 V kA 37,5 63.5fuse manufacturers7) Max. OFA_ fuse size gG/aM A 250 /2508) 500/5008)

(single phase test acc. to IEC60269) at prospective SC-current 50 kA, 690 V kA 29,5 32Max. OFA_ fuse size gG/aM A 250/- 355/-at prospective SC-current 80 kA, 690 V kA 32,5 38Max. OFA_ fuse size gG/aM A 200/2508) 355/4008)

at prospective SC-current 50 kA, 415 V kA 26 28 34Max. BS fuse size gG/gM A 250/- 315/- 400/-at prospective SC-current 80 kA, 415 V kA 30 50 50Max. BS fuse size gG/gM A 250/200M2508) 400/400M5008) 400/400M5008)

at prospective SC-current 50 kA, 690 V kA 28 30 38Max. BS fuse size gG/gM A 250/- 315/- 400/-at prospective SC-current 80 kA, 690 V kA 28 48 48Max. BS fuse size gG/gM A 250/200M2508) 400/400M4508) 400/400M4508)

Rated short-time withstand current, 1s. r.m.s. -value kA 8 14 14Max. distance from switch frame mm 150 150 150to nearest busbar/cable support

Rated capacitor power The capacitor rating of the switch- 400 V/415 V kVArwhen there is no initial charge on the capacitor fuse is limited by the fuse link 690 V kVArPower loss/pole With rated current, without fuse BB, BD, UB W 13 19 30

P_, L_, _R, _L, LR W 17 25 40Mechanical endurance Divide by two for operation cycles Oper. 20 000 16 000 16 000Fuse types, IEC 60269-2 DIN 43620 BB, BD, UB 0 - 1 0 - 2

P_, L_, _R, _L, LR 0 - 1 0 - 2BS 88 BB, BD, UB B1 - B34) B1 - B46) B1 - B46)

-size/distance of fuse-link bolts BB, BD, UB mm M8/111 M8/111 M8/111BS 88 P_, L_, _R, _L, LR B1 - B34) B1 - B46) B1 - B46)

-size/distance of fuse-link bolts P_, L_, _R, _L, LR mm M8/111 M8/111 M8/111Terminal tightening torque Counter torque required Nm M8:15-225),M10:30-44 M8:15-225),M10:30-44 M8:15-225),M10:30-44

Fuse-links bolts tightening torque BB, BD, UB Nm 5 20 20P_, L_, _R, _L, LR Nm 5 20 20

Operating torque Typical for 3 and 4-pole switches Nm 7 19 19

*) B category.1) Ambient temperature 60 °C: derating 20%; mounting on ceiling: derating 10%; mounting on wall, horizontal fuses: derating 8%. OS160G: Mounting on wall, horizontal fuses: derating 5%.2) Some fuse links limit these figures further. Starting current characteristics must be considered separately. 3) Plug in types: fuse size gG/aM:400/400. 4) Max fuse body dia 52 mm. 5) Side terminals tightening torque max 15 Nm.6) Max fuse body dia 62 mm.7) BS fuse manufacturers covered by this table ABB, MEM, Bussmann, GEC.8) 3-pole types only. 9) Acc. to IEC 60947-1, § 6.1.1. Minimum ambient temperature -5°C.Category B: -5°C...-35°C.

Page 13: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Technical data 13

Technical data, UL/CSAFusible disconnect switches OS30...200

OS Mini OS OS OSSwitch size A 30 60G 100G 200

Approvals*) 2 pole - UL98, IEC UL98, IEC UL98, IEC3 pole UL98, IEC UL98, IEC UL98, IEC UL98, IEC4 pole UL98, IEC UL98, IEC UL98, IEC UL98, IEC

Technical data according to UL/CSAGeneral purpose amp rating pf= 0.7...0.8 up to 40 ºC A 30 60 100 200Max. oprerating voltage VAC 600 600 600 600

VDC 250 250 250Max. horsepower rating / motor FLA current pf= 0.4...0.5 Three phase 240 V HP/A 7.5/22.0 15/42.0 30/80.0 60/154.0

480 V HP/A 15/21.0 30/40.0 60/77.0 125/156.0600 V HP/A 20/22.0 50/52.0 75/77.0 150/144.0

Single phase 120 V HP/A 2/24.0240 V HP/A 3/17.0

Short circuit rating with fuse, 3 and4-pole types kA 200 200 200 200UL/CSA fuse size A 30 60 100 200UL/CSA fuse type J/CC J J J

Min. electrical endurance pf= 0.75...0.8 operation cycles 6000 6000 6000 6000Terminal lug kits Integral Integral OZXA-24 OZXA-200Wire range AWG #18-8 #14-4 #14-2/0 #4-300MCMTorque Wire tightening lb.in 17 30/354) 120 275

Lug mounting lb.in N/A N/A 50 72

Technical data according to IEC 60947-3Rated insulation voltage Pollution degree 3 V 1 000 1 000 1 000 1 000Dielectric strength 50 Hz 1min. kV 10 10 10 10Rated impulse withstand voltage kV 12 12Rated thermal current in ambient 40 °C/ In open air A/W 32/3.5 63/7.5 160/12 200/17max. fuse power dissipation1) In enclosure2) A/W 32/3.5 63/7.5 160/10,135/12 200/15...with minimum cable cross section Cu mm2 6 16 70 95Rated operational current, AC-23A up to 500 V A 32 63 160 200

690 V A 32 63 160 200Rated operational power, AC-233) The kW-ratings are accurate for 230 V kW 7.5 18.5 45 60

three-phase 1500 R.P.M. 400 V kW 15 30 75 110standard asynchronous motors. 415 V kW 15 30 75 110

500 V kW 18.5 37 90 132690 V kW 22 55 132 200

Rated breaking capacity in category AC-23 up to 500 V A 256 504 1280 1600690 V A 256 504 1280 1600

Rated short-time withstand current, 1 s r.m.s. -value kA 1 2.5 5 8Power loss / pole With rated current, without fuse W 2 4 9 8Built-in terminal size Cu mm2 0.75...10 2.5...25 Fuse-links bolts tightening torque Nm 4 4

*) UL listed disconnects are also listed under CSA requirements 1) Ambient temperature 60 °C: derating 20% 2) Mounting on "ceiling": derating 10%. Mounting on wall, horizontal fuses: derating 8%. 3) Some fuse links limit these figures further. Starting current characteristics must be considered separately. 4) 30 lb.in with cable size #14-10, 35 lb.in with cable size #8-4

Page 14: Switch fuses OS and OSM - ABB

14 Technical data | Switch fuses OS and OSM

Technical data, UL/CSAFusible disconnect switches OS400...1200

OS OS OS OSSwitch size A 400 600 800 1200

Approvals *) 2 pole UL98, IEC UL98, IEC UL98, IEC UL98, IEC3 pole UL98, IEC UL98, IEC UL98, IEC UL98, IEC4 pole UL98, IEC UL98, IEC UL98, IEC UL98, IEC

Technical data according to UL/CSAGeneral purpose amp rating pf= 0.7...0.8 up to 40 ºC A 400 600 800 1200Max. oprerating voltage VAC 600 600 600 600

VDC 250 250 250 250Max. horsepower rating / motor FLA current pf= 0.4...0.5 Three phase 240 V HP/A 125.0/312.0 200/480.0 250/602.0

480 V HP/A 250.0/302.0 400/477.0 500/590.0600 V HP/A 350.0/336.0 500/472.0 500/472.0

Single phase 120 V HP/A240 V HP/A

Short circuit r ating with fuse, 3 and4-pole types kA 200 200 200 200UL/CSA fuse size A 400 600 800 1200UL/CSA fuse type J J L L

Min. electrical endurance pf= 0.75...0.8 operation cycles 1000 1000 500 500Terminal lug kits OZXA-400 OZXA-800 OZXA-800 OZXA-1200Wire range AWG #2-600MCM (2)#2-600MCM (2)#2-600MCM (4)#2-600MCMTorque Wire tightening lb.in 375 500 500 500

Lug mounting lb.in 240 480 480 480

Technical data according to IEC 60947-3Rated insulation voltage Pollution degree 3 V 1 000 1 000 1 000 1000Dielectric strength 50 Hz 1min. kV 10 10 10 10Rated impulse withstand voltage kV 12 12 12 12Rated thermal current in ambient 40 °C/ In open air A/W 400/45 630/60 800/65 1250/110max. fuse power dissipation1) In enclosure2) A/W 400/30 570/50 720/55 1000/85...with minimum cable cross section Cu mm2 240 2x185 2x240 2x400Rated operational current, AC-23A up to 500 V A 400 630 800 10004)

690 V A 400 630 800 10004)

Rated operational power, AC-233) The kW-ratings are accurate for 230 V kW 132 200 250 3154)

three-phase 1500 R.P.M. 400 V kW 220 355 450 5604)

standard asynchronous motors. 415 V kW 230 355 450 5604)

500 V kW 280 450 560 7104)

690 V kW 400 630 710 10004)

Rated breaking capacity in category AC-23 up to 500 V A 3200 6400 6400 8000690 V A 3200 6400 6400 8000

Rated short-time withstand current, 1 s r.m.s. -value kA 14 20 20Power loss / pole With rated current, without fuse W 30 46 75 75Built-in terminal size Cu mm2

Fuse-links bolts tightening torque Nm 20 40 40 401) Ambient temperature 60 °C: derating 20% 2) Mounting on "ceiling": derating 10%. Mounting on wall, horizontal fuses: derating 8%. 3) Some fuse links limit these figures further. Starting current characteristics must be considered separately. 4) = Utilization category B *) UL listed disconnects are also listed under CSA requirements

Page 15: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Technical data 15

Technical data, UL/CSAFusible disconnect switches OS400...1200

Data for motor operator OSM according to IEC 60947 Switch size A 32…63 100…160 200…250

Rated operational voltage Ue Pollution degree 3

50/60 Hz V AC 220 - 240 220 - 240

Operating voltage range 0.85 - 1.1 x Ue 0.85 - 1.1 x Ue 0.85 - 1.1 x Ue

Operating time1) 90° I - 0, 0 - I 220-240VAC s 0.5 - 1.0 0.5 - 1.0 0.5 - 1.0

Nominal current In1) 220-240VAC A 0.3 0.3 0.3

Current Inrush1) 220-240VAC A 1.5 1.5 1.5

Overload fuse Type / In / Capacity 220-240VAC mA T / 315 / H T / 315 / H T / 315 / H

Size mm 5x20 5x20 5x20

Operating rate Cycle 0 - I - 0

Max. continuous 220-240VAC cycles / min 1 1 1

Max. short-time ≤ 10 cycles 220-240VAC cycles / min 10 10 10

Overvoltage category III III III

Rated impulse withstand voltage Uimp kV 4 4 4

Dielectric strength 50 Hz 1 min. kV 1.5 1.5 1.5

Impulse command Min. impulse

duration ms 100 100

Terminals

Voltage supply wiring for Ue PE - N - L PE - N - L PE - N - L PE - N - L

Cross section solid/stranded mm2 1.5 - 2.5 1.5 - 2.5 1.5 - 2.5

Short-circuit protection device max.fuse size A 16 16 16

Push-button control C - I - O no SELV no SELV no SELV

Cross section solid/stranded mm2 1.5 - 2.5 1.5 - 2.5 1.5 - 2.5

Maximum cable length m 100 100 100

State information of locking no SELV no SELV no SELV

Handle attached or motor operator locked 11-12-14 (C/O) cosϕ=1 5A/250V 5A/250V 5A/250V

Locking motor operator 23-24 (NO) cosϕ=1 5A/250V 5A/250V 5A/250V

Short-circuit protection device MCB type and size C/2A C/2A C/2A

Protection degree IP20 IP20 IP20

Operating temperature °C -25…+55 -25…+55 -25…+55

Transportation and storage temperature °C -40…+70 -40…+70 -40…+70

Max. altitude m 2000 2000 20001) Under nominal conditions

Technical data, motor operators, IEC Motorized switch fuses OSM32...250

Page 16: Switch fuses OS and OSM - ABB

16 Technical data | Switch fuses OS and OSM

Data for motor operator OSM according to IEC 60947 Switch size A 315...400 630…800 1250

Rated operational voltage Ue Pollution degree 3

50/60 Hz V AC 220 - 240 220 - 240 220 - 240

Operating voltage range 0.85 - 1.1 x Ue 0.85 - 1.1 x Ue 0.85 - 1.1 x Ue

Operating time1) 90° I - 0, 0 - I 220-240VAC s 0.5 - 1.2 0.5 - 1.5 0.8 - 2.0

Nominal current In1) 220-240VAC A 0.5 0.9 1.4

Current Inrush1) 220-240VAC A 2.5 4 10

Overload fuse Type / In / Capacity 220-240VAC mA T / 500 / H T / 1000 / H T / 2000 / H

Size mm 5x20 5x20 5x20

Operating rate Cycle 0 - I - 0

Max. continuous 220-240VAC cycles / min 1 1 0.5

Max. short-time ≤ 10 cycles 220-240VAC cycles / min 10 10 5

Overvoltage category III III

Rated impulse withstand voltage Uimp kV 4 4

Dielectric strength 50 Hz 1 min. kV 1.5 1.5

Impulse command Min. impulse

duration ms 100 100

Terminals

Voltage supply wiring for Ue PE - N - L PE - N - L PE - N - L

Cross section solid/stranded mm2 1.5 - 2.5 1.5 - 2.5 1.5 - 2.5

Short-circuit protection device max.fuse size A 16 16 16

Push-button control C - I - O no SELV no SELV no SELV

Cross section solid/stranded mm2 1.5 - 2.5 1.5 - 2.5 1.5 - 2.5

Maximum cable length m 100 100 100

State information of locking no SELV no SELV no SELV

Handle attached or motor operator locked 11-12-14 (C/O) cosϕ=1 5A/250V 5A/250V 5A/250V

Locking motor operator 23-24 (NO) cosϕ=1 5A/250V 5A/250V 5A/250V

Short-circuit protection device MCB type and size C/2A C/2A C/2A

Protection degree IP20 IP20 IP20

Operating temperature °C -25…+55 -25…+55 -25…+55

Transportation and storage temperature °C -40…+70 -40…+70 -40…+70

Max. altitude m 2000 2000 20001) Under nominal conditions

Technical data, motor operators, IEC Motorized switch fuses OSM315...1250

Page 17: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Type designation key 17

Type designation key

Explanation of the types OS32…1250 A

OS 125G D _ 04 N2 _ P1 2 3 4 5 6 7 8

1 - Brand 12: 3 poles, operating mechanism between the poles

OS ABB switch fuse/fusible switch 22: 4 poles, operating mechanism between the poles

2- Switch size/ Ampere rating 30: 3 poles, operating mechanism at the right end of the switch

32G…200G Gamma, 32A…200A 40: 4 poles, operating mechanism at the right end of the switch

200…1250 200A…1250 A 6- Fourth pole/neutral terminal

3- Fuse type Blank Neutral terminal not included

D DIN N1 Non-fused switched neutral on the left side

B BS N2 Non-fused switched neutral on the right side

F NFC N3 Includes a detachable neutral link integrated into the mechanism

J J F Fused switch neutral

L L 7 - Terminals for special connection (only IEC)

4- Switch operation Blank No special connection

Blank: Front operation BB Back in, back out

S Side operation LR Left in, right out

5 - Number of poles and placing of the operating mechanism 8 - Included handle

03 3 poles, operating mechanism at the left end of the switch Blank No handle included

04 4 poles, operating mechanism at the left end of the switch P Pistol handle and shaft

K Direct mount handle

Explanation of the types OS20…40

OS 25F F _ 22 10 N1 -21 2 3 4 5 6 7 8

1 - Brand 5 - Number of poles and placing of the operating mechanism

OS ABB switch fuse/fusible switch 12 3 poles, operating mechanism between the poles

2- Switch size/ Ampere rating 22 4 poles, operating mechanism between the poles

20...40F Mini, 20…40 A 30 3 poles, operating mechanism at the right end of the switch

3- Fuse type 6- Fuse size

D DIN A1, A2 BS88, A1, A2

B BS 000 DIN 000

F NFC 10, 14 NFC 10x38, 14x51

AJ J 7- Fourth pole/neutral terminal

ACC CC N1 Non-fused switched neutral on the left side

4- Switch operation F Fused switched neutral

Blank Front operation Blank Terminal not included

S Side operation 8 - Included handle

Blank Pistol handle and shaft included

-2 No handle included

Page 18: Switch fuses OS and OSM - ABB

18 Type designation key | Switch fuses OS and OSM

Type designation key

Explanation of the types OSM…1250 A (IEC only)

OSM 125G B 4 N1 M230C1 2 3 4 5 6

1 - Brand 4: 4 poles, motor operator at the left end of the switch

OSM ABB motorized switch fuse 5- Fourth pole/neutral terminal

2- Switch size/ Ampere rating N1 Non-fused switched neutral on the left side

32G…200G Gamma, 32A…200A N2 Non-fused switched neutral on the right side

200…1250 200A…1250 A N3 Includes a detachable neutral link integrated into the mechanism

3- Fuse type Blank Neutral terminal not included

B BS 6- Motor operator voltage

D DIN 230C 230 V AC

4 - Number of poles

3: 3 poles, motor operator at the left end of the switch

At the end of the switch fuse OS_03 or 04

Between the polesOS_12 or 22

Side operatedtypesOS_30 or 40 OS_03 or 04

Placing options of the operating mechanism

NN N

LR-typesBB-types

NN

N N

N

Page 19: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 19

Ordering information, IECSwitch fuses, DIN-type

Front operated switch fusesIncluding terminal bolt set in OS125G...160G, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

Protected tunnel terminals, IP20

32 000 2 OS32GD02P 1SCA116714R1001 1.0

32 000 3 OS32GD03P 1SCA115189R1001 1.3

32 000 4 OS32GD04N2P 1SCA115193R1001 1.6

32 000 4 OS32GD04FP 1SCA115196R1001 1.6

63 000 2 OS63GD02P 1SCA116715R1001 1.0

63 000 3 OS63GD03P 1SCA115207R1001 1.3

63 000 4 OS63GD04N2P 1SCA115209R1001 1.6

63 000 4 OS63GD04FP 1SCA115228R1001 1.6

Including terminal bolt set

125 000, 00 2 OS125GD02P 1SCA116716R1001 1.2

125 000, 00 3 OS125GD03P 1SCA115639R1001 1.5

125 000, 00 4 OS125GD04N2P 1SCA115877R1001 1.8

125 000, 00 4 OS125GD04FP 1SCA115686R1001 1.8

160 000, 00 2 OS160GD02P 1SCA116717R1001 1.2

160 000, 00 3 OS160GD03P 1SCA115399R1001 1.5

160 000, 00 4 OS160GD04N2P 1SCA115882R1001 1.8

160 000, 00 4 OS160GD04FP 1SCA115402R1001 1.8

F = Fused switched neutral

N2 = Non-fused switched neutral on the right side

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS32G...63G_P OXP6X161 OHB45J6 -

OS125G...160G_P OXP6X161 OHB65J6 M8X25

OS32...63GD02P

OS32...63GD04FP

OS32...63GD04N2P

OS125...160GD03P

Page 20: Switch fuses OS and OSM - ABB

20 Ordering information | Switch fuses OS and OSM

Ordering information, IECSwitch fuses, DIN-type

Front operated switch fusesIncluding terminal bolt set, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

200 00 3 OS200DZ03P 1SCA022797R3440 3.3

200 00 4 OS200DZ04N2P 1SCA022820R9230 4.2

200 0 2 OS200D02P 1SCA022759R9220 2.4

200 0 3 OS200D03P 1SCA022709R9500 3.3

200 0 3+N OS200D03N3P 1SCA022749R8710 3.4

200 0 4 OS200D04N2P 1SCA022709R9680 4.2

200 0 4 OS200D04FP 1SCA022725R4750 4.2

250 0-1 2 OS250D02P 1SCA022760R0170 3.5

250 0-1 3 OS250D03P 1SCA022719R0090 4.3

250 0-1 3+N OS250D03N3P 1SCA022749R9430 4.4

250 0-1 4 OS250D04N2P 1SCA022719R2380 5.1

250 0-1 4 OS250D04FP 1SCA022726R8620 5.1

400 0-2 2 OS400D02P 1SCA022811R2740 5.4

400 0-2 3 OS400D03P 1SCA022719R0250 7.1

400 0-2 3+N OS400D03N3P 1SCA022753R9320 7.5

400 0-2 4 OS400D04N2P 1SCA022719R2460 9.1

400 0-2 4 OS400D04FP 1SCA022753R7110 9.1

F = Fused switched neutral, N2 = Non-fused switched neutral on the right side

N3 = Include a detachable neutral link integrated into the mechanism

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS200_P OXP6X210 OHB65J6 M8X25

OS250_P OXP6X210 OHB65J6 M10X30

OS400_P OXP12X250 OHB95J12 M10X30

OS200DZ04N2P

OS200...250D03N3P

OS200...250D02P

OS400D04FP

Page 21: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 21

Ordering information, IECSwitch fuses, DIN-type

Front operated switch fusesIncluding terminal bolt set, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths. OS1250DA_: a fuse replacement tool is integrated in the fuse cover.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

630 3 2 OS630D02P 1SCA107745R1001 10.3

630 3 3 OS630D03P 1SCA022825R2830 13.6

630 3 3+N OS630D03N3P 1SCA100858R1001 14.5

630 3 4 OS630D04N2P 1SCA022825R4290 16.9

630 3 4 OS630D04FP 1SCA022825R4610 16.9

800 3 2 OS800D02P 1SCA022837R2650 10.3

800 3 3 OS800D03P 1SCA022825R4880 13.6

800 3 3+N OS800D03N3P 1SCA100859R1001 14.5

800 3 4 OS800D04N2P 1SCA022825R5180 16.9

800 3 4 OS800D04FP 1SCA022825R5000 16.9

12501) 4 2 OS1250D02P 1SCA114051R1001 37

12501) 4 3 OS1250D03P 1SCA105475R1001 46

12501) 4 3+N OS1250D03N3P 1SCA107932R1001 47

12501) 4 4 OS1250D04N2P 1SCA105248R1001 55

12501) 4 4 OS1250D04FP 1SCA105473R1001 55

12501) 4a 2 OS1250DA02P 1SCA114059R1001 37

12501) 4a 3 OS1250DA03P 1SCA105238R1001 46

12501) 4a 3+N OS1250DA03N3P 1SCA107934R1001 47

12501) 4a 4 OS1250DA04N2P 1SCA105243R1001 55

12501) 4a 4 OS1250DA04FP 1SCA105240R1001 55

F = Fused switched neutral, N2 = Non-fused switched neutral on the right side

N3 = Include a detachable neutral link integrated into the mechanism

1) 1250A / AC-21...22A, 1000A / AC-23A

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS630...800_P OXP12X280 OHB145J12 M12X40

OS1250_P OXP12X395 OHB274J12 M12x50

OS630...800D02P

OS1250D03P

OS630...800D04FP

OS1250D04P

Page 22: Switch fuses OS and OSM - ABB

22 Ordering information | Switch fuses OS and OSM

Ordering information, IECSwitch fuses, DIN-type

Front operated switch fuses with direct mount handleIncluding terminal bolt set in OS125G...160G, a black Test-OFF-ON plastic handle and shaft as standard. The handle is padlockable in the OFF-position. Types OS1250DA_: a fuse replacement tool is integrated in the fuse cover.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

Protected tunnel terminals, IP20

32 000 3 OS32GD03K 1SCA116733R1001 1.3

32 000 4 OS32GD04N2K 1SCA116734R1001 1.6

32 000 4 OS32GD04FK 1SCA116737R1001 1.6

63 000 3 OS63GD03K 1SCA116738R1001 1.3

63 000 4 OS63GD04N2K 1SCA116876R1001 1.6

63 000 4 OS63GD04FK 1SCA116739R1001 1.6

Including terminal bolt set

125 000, 00 3 OS125GD03K 1SCA116878R1001 1.5

125 000, 00 4 OS125GD04N2K 1SCA116740R1001 1.8

125 000, 00 4 OS125GD04FK 1SCA116741R1001 1.8

160 000, 00 3 OS160GD03K 1SCA116742R1001 1.5

160 000, 00 4 OS160GD04N2K 1SCA116743R1001 1.8

160 000, 00 4 OS160GD04FK 1SCA116880R1001 1.8

F = Fused fourth pole

N2 = Non-fused switched neutral on the right side

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS32G...63G_K - OSV200BK -

OS125G...160G_K - OSV200BK M8X25

OS32...63GD03K

OS125...160GD03K

OS32...63GD04N2K

OS125...160GD04FK

Page 23: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 23

Front operated switch fuses with direct mount handleIncluding terminal bolt set, a black Test-OFF-ON plastic handle and shaft as standard. The handle is padlockable in the OFF-position. Types OS1250DA_: a fuse replacement tool is integrated in the fuse cover.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

Including terminal bolt set

200 0 3 OS200D03K 1SCA022764R7130 3.3

200 0 4 OS200D04N2K 1SCA022768R7430 4.2

250 0-1 3 OS250D03K 1SCA022763R6360 4.3

250 0-1 4 OS250D04N2K 1SCA022763R6440 5.1

400 0-2 3 OS400D03K 1SCA022779R5410 7.0

400 0-2 4 OS400D04N2K 1SCA022763R7250 9.0

630 3 3 OS630D03K 1SCA108704R1001 13

630 3 4 OS630D04N2K 1SCA108705R1001 16

800 3 3 OS800D03K 1SCA108725R1001 13

800 3 4 OS800D04N2K 1SCA108722R1001 16

12501) 4 3 OS1250D03K 1SCA108718R1001 45

12501) 4 4 OS1250D04N2K 1SCA108719R1001 54

12501) 4a 3 OS1250DA03K 1SCA108720R1001 45

12501) 4a 4 OS1250DA04N2K 1SCA108721R1001 54

N2 = Non-fused switched neutral on the right side

1) 1250A / AC-20...22A, 1000A / AC-23A

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS200_K - OSV250DK M8X25

OS250_K - OSV250DK M10X30

OS400_K - OSV400DK M10X30

OS630...800_K - OSV800DK M12X40

OS1250_K - OSV1250DK M12x50

Ordering information, IECSwitch fuses, DIN-type

OS200...250D03K

OS400D03K

OS630...800D03K

Page 24: Switch fuses OS and OSM - ABB

24 Ordering information | Switch fuses OS and OSM

Ordering information, IECSwitch fuses, DIN-type

Side operated switch fuses with pistol handleIncluding a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Shaft mounting depths measured from the left side of the switch, 3-pole: H=157…164 mm and 4-pole:

H= 193…200 mm. Protected tunnel terminals, IP20.

40 000 3 OS40FDS30000 1SCA108942R1001 0.9

40 000 3 OS40FDS30000-2 1SCA108945R1001 0.7

Side operated switch fuses with direct mount handleIncluding terminal bolt set in OS125G...160G, a black Test-ON-OFF plastic handle and shaft as standard. The handle is padlockable in the OFF-position.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Protected tunnel terminals, IP20.

32 000  3 OS32GDS30K 1SCA115929R1001 1.3

32 000  4 OS32GDS40N2K 1SCA116402R1001 1.6

63 000  3 OS63GDS30K 1SCA115931R1001 1.3

63 000  4 OS63GDS40N2K 1SCA116403R1001 1.6

Including terminal bolt set

125 000, 00  3 OS125GDS30K 1SCA115933R1001 1.5

125 000, 00  4 OS125GDS40N2K 1SCA115934R1001 1.8

160 000, 00  3 OS160GDS30K 1SCA115935R1001 1.5

160 000, 00  4 OS160GDS40N2K 1SCA115939R1001 1.8

N2 = Non-fused switched neutral on the right side

Shafts and handles incl. as standardSuitable for switches Included shaft Included handle Incl. terminal bolts

OS40FDS_ (OS Mini) OPX6X150 OHB65J6 -

OS32G...63_K OXP6X42-TO OHB65D6 -

OS125G...160G_K OXP6X42-TO OHB65D6 M8X25

OS32...63GDS30K

OS32...63GDS40N2K

OS125...160GDS40N2K

Page 25: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 25

Ordering information, IECSwitch fuses, DIN-type

Side operated switch fuses with direct mount handleIncluding terminal bolt set, a black Test-ON-OFF plastic handle and shaft as standard. The handle is padlockable in the OFF-position.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Including terminal bolt set

200 0 3 OS200DS30K 1SCA022871R1450 3.6

200 0 4 OS200DS40FK 1SCA022871R1610 4.5

250 0-1 3 OS250DS30K 1SCA022871R2260 4.6

250 0-1 4 OS250DS40FK 1SCA022871R2420 5.4

400 0-2 3 OS400DS30K 1SCA022871R2930 7.5

400 0-2 4 OS400DS40FK 1SCA022871R3150 9.5

630 3 3 OS630DS30K 1SCA108136R1001 14.1

630 3 4 OS630DS40FK 1SCA108138R1001 17

800 3 3 OS800DS30K 1SCA108099R1001 14.1

800 3 4 OS800DS40FK 1SCA108101R1001 17

F = Fused switched neutral

Shafts and handles included as standard:

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS200_K OXP6X42-TO OHB65D6 M8x25

OS250_K OXP6X42-TO OHB65D6 M10x30

OS315...400_K OXP12X47-TO OHB95D12 M10x30

OS630…800_K OXP12X59-TO OHB145D12 M12x40

OS200...250DS40FK

OS630...800DS04FK

Page 26: Switch fuses OS and OSM - ABB

26 Ordering information | Switch fuses OS and OSM

Special connected switch fuses, back in, back out connection (BB)Including terminal bolt set, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse*) of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

125 000, 00 3 OS125GD03BBP 1SCA120802R1001 2.3

125 000, 00 4 OS125GD04BBN2P 1SCA120806R1001 2.7

160 000, 00 3 OS160GD03BBP 1SCA120655R1001 2.3

160 000, 00 4 OS160GD04BBN2P 1SCA120661R1001 2.7

200 0 3 OS200D03BBP 1SCA102150R1001 3.3

200 0 4 OS200D04BBN2P 1SCA102139R1001 4.2

250 0...1 3 OS250D03BBP 1SCA102190R1001 4.3

250 0...1 4 OS250D04BBN2P 1SCA102205R1001 5.1

400 0…2 3 OS400D03BBP 1SCA102260R1001 7.1

400 0…2 4 OS400D04BBN2P 1SCA102289R1001 9.1

N2 = Non-fused switched neutral on the right side

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS125G_...160G_P OXP6X161 OHB65J6 M8x25

OS200_P OXP6X210 OHB65J6 M8x25

OS250_P OXP6X210 OHB65J6 M10x30

OS400_P OXP12X250 OHB95J12 M10x30

Ordering information, IECSwitch fuses, DIN-type

OS250D03BBP

OS250D04BBN2P

Page 27: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 27

Ordering information, IECSwitch fuses, DIN-type

Special connected switch fuses, left in, right out connection (LR)Including terminal bolt set, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths. Terminal angles for side terminals are accessories and are not included in standard delivery.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse*) of unit

[A] size poles Type Order number [kg]

Mechanism between the poles

125 000, 00 3 OS125GD12LRP 1SCA120062R1001 2.9

125 000, 00 3 OS125GD21LRP 1SCA120255R1001 2.9

125 000, 00 4 OS125GD22LRP 1SCA120263R1001 3.7

160 000, 00 3 OS160GD12LRP 1SCA120267R1001 2.9

160 000, 00 3 OS160GD21LRP 1SCA120294R1001 2.9

160 000, 00 4 OS160GD22LRP 1SCA120275R1001 3.7

250 0...1 3 OS250D12LRP 1SCA022852R8410 6.2

250 0...1 3 OS250D21LRP 1SCA022852R8500 6.2

250 0...1 4 OS250D22LRP 1SCA022853R0310 9.1

400 0…2 3 OS400D12LRP 1SCA022853R2280 9.6

400 0…2 3 OS400D21LRP 1SCA022853R2360 9.6

400 0…2 4 OS400D22LRP 1SCA022853R4140 12.8

Fuse standards DIN 43620, IEC 60269-2 sec. I

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS125G_...160G_P OXP6X161 OHB65J6 M8x25

OS250_P OXP6X210 OHB65J6 M8x16

OS400_P OXP12X250 OHB95J12 M8x16

OS125...160GD12LRP

OS200...250D22LR

OS400D12LRP

Page 28: Switch fuses OS and OSM - ABB

28 Ordering information | Switch fuses OS and OSM

Front operated switch fusesIncluding terminal bolt set in OS100G...160G, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Protected tunnel terminals IP20, mechanism at the end of the switch

32 A2, A3 2 OS32GB02P 1SCA116721R1001 1.0

32 A2, A3 3 OS32GB03P 1SCA115259R1001 1.3

32 A2, A3 4 OS32GB04N1P 1SCA114610R1001 1.6

63 A2, A3 2 OS63GB02P 1SCA116854R1001 1.0

63 A2, A3 3 OS63GB03P 1SCA115235R1001 1.3

63 A2, A3 4 OS63GB04N1P 1SCA115238R1001 1.6

Including terminal bolt set, mechanism at the end of the switch

100 A2-A41) 3 OS100GB03P 1SCA114613R1001 1.8

100 A2-A41) 3+N OS100GB03N3P 1SCA125531R1001 2.1

100 A2-A41) 4 OS100GB04N1P 1SCA114614R1001 2.5

125 A2-A41) 3 OS125GB03P 1SCA115634R1001 1.7

125 A2-A41) 3+N OS125GB03N3P 1SCA122008R1001 2.1

125 A2-A41) 4 OS125GB04N1P 1SCA115901R1001 2.7

160 A2-A41) 3 OS160GB03P 1SCA115413R1001 1.8

160 A2-A41) 3+N OS160GB03N3P 1SCA122010R1001 2.1

160 A2-A41) 4 OS160GB04N1P 1SCA115896R1001 2.5

N1 = Non-fused switched neutral on the left side N3=Detachable neutral link integrated into the mechanism 1) Max. fuse diameter 32 mm

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS32G...63G_P OXP6X161 OHB45J6 -

OS100G...160G_P OXP6X161 OHB65J6 M8X25

Ordering information, IECSwitch fuses, BS-type

OS32...63GB02P

OS32...63GB04N1P

OS100...160GB03P

OS100...160GB03N3P

Page 29: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 29

Front operated switch fusesIncluding terminal bolt set, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft can be adjusted to different installation depths.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

200 B1-B2 2 OS200B02P 1SCA022769R7820 2.4

200 B1-B2 3 OS200B03P 1SCA022709R9330 3.3

200 B1-B2 3+N OS200B03N3P 1SCA022750R0620 3.4

250 B1-B3 2 OS250B02P 1SCA022769R9440 3.5

250 B1-B3 3 OS250B03P 1SCA022750R6660 4.3

250 B1-B3 3+N OS250B03N3P 1SCA022750R8010 4.4

315 B1-B4 2 OS315B02P 1SCA022817R3450 5.4

315 B1-B4 3 OS315B03P 1SCA022719R0680 7.1

315 B1-B4 3+N OS315B03N3P 1SCA022753R8940 7.5

400 B1-B4 2 OS400B02P 1SCA022813R7220 5.4

400 B1-B4 3 OS400B03P 1SCA022719R0840 7.1

400 B1-B4 3+N OS400B03N3P 1SCA022753R9160 7.5

N3 = Include a detachable neutral link integrated into the mechanism.

OS200GB_P are optimal for electrical distribution applications and are compact in size.

Rated op.

current

AC-20...22B No. Weight/

≤ 415V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

200 A2-A41) 3 OS200GB03P 1SCA125468R1001 2.3

200 A2-A41) 3+N OS200GB03N3P 1SCA126216R1001 2.3

200 A2-A41) 4 OS200GB04N1P 1SCA125493R1001 2.7

N1 = Non-neutral on the right side N3 = Include a detachable neutral link integrated into the mechanism.

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS200_GB_P OXP6X161 OHB65J6 M8X25

OS200_P OXP6X210 OHB65J6 M8X25

OS250_P OXP6X210 OHB65J6 M10X30

OS315…400_P OXP12X250 OHB95J12 M10X30

Ordering information, IECSwitch fuses, BS-type

OS200...250B02P

OS200...250B03N3P

OS315...400B03P

Page 30: Switch fuses OS and OSM - ABB

30 Ordering information | Switch fuses OS and OSM

Front operated switch fusesIncluding terminal bolt set, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

630 C1-C2 2 OS630B02P 1SCA113529R1001 10.3

630 C1-C2 3 OS630B03P 1SCA022825R5850 13.6

630 C1-C2 3+N OS630B03N3P 1SCA100860R1001 14.5

800 C1-C3 2 OS800B02P 1SCA022837R6480 10.3

800 C1-C3 3 OS800B03P 1SCA022825R7550 13.6

800 C1-C3 3+N OS800B03N3P 1SCA100861R1001 14.5

12501) D1 2 OS1250B02P 1SCA114070R1001 37

12501) D1 3 OS1250B03P 1SCA105250R1001 46

12501) D1 3+N OS1250B03N3P 1SCA107936R1001 47

N3 = Include a detachable neutral link integrated into the mechanism.1) 1250A / AC-20...22A, 1000A / AC-23A

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS630...800_P OXP12X280 OHB145J12 M12X40

OS1250_P OXP12X395 OHB274J12 M12X50

Ordering information, IECSwitch fuses, BS-type

OS630...800B02P

OS630...800B03N3P

OS1250D03P

Page 31: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 31

Front operated switch fusesThese types (-42) have nuts integrated on the back of the terminals, for easy installation. A black ON-OFF plastic handle and shaft included as standard. The handle is IP 54 protected, padlockable in OFF position and has door interlock in the ON-position and when padlocked.The shaft can be adjusted to different installation depth.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism Mechanism between the poles

100 A2-A41) 3+N OS100GB12N3P-42 1SCA129910R1001 2.7

125 A2-A41) 3+N OS125GB12N3P-42 1SCA129914R1001 2.7

160 A2-A41) 3+N OS160GB12N3P-42 1SCA129919R1001 2.7

Mechanism at the end of the switch fuse

100 A2-A41) 3 OS100GB03P-42 1SCA128217R1001 1.7

100 A2-A41) 3+N OS100GB03N3P-42 1SCA129907R1001 2.7

125 A2-A41) 4 OS125GB03P-42 1SCA128215R1001 2.3

125 A2-A41) 3+N OS125GB03N3P-42 1SCA129912R1001 2.7

160 A2-A41) 3 OS160GB03P-42 1SCA128213R1001 2.3

160 A2-A41) 3+N OS160GB03N3P-42 1SCA129916R1001 2.7

N3 = Include a detachable neutral link integrated into the mechanism1) Max. fuse diameter 32 mm

Rated op

current

AC20B-AC22B No. Weight/

≤ 415V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

200 A2-A41) 3 OS200GB03P-42 1SCA128211R1001 2.3

200 A2-A41) 3+N OS200GB03N3P-42 1SCA129922R1001 2.7

N3 = Include a detachable neutral link integrated into the mechanism1) Max. fuse diameter 32 mm

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS100...125GB_P-42 OXP6X161 OHB65J6 M8x25

Ordering information, IECSwitch fuses, BS-type

OS100...200GB03P-42

OS100...160GB12P-42

OS100...200GB03N3P-42

Terminals with integrated nuts

Page 32: Switch fuses OS and OSM - ABB

32 Ordering information | Switch fuses OS and OSM

Front operated switch fuses with direct mount handleIncluding terminal bolt set in OS100G...160G, a black Test-OFF-ON plastic handle and shaft as standard. The handle is padlockable in the OFF-position.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

Protected tunnel terminals, IP20

32 A2, A3  3 OS32GB03K 1SCA116744R1001 1.3

32 A2, A3  4 OS32GB04N1K 1SCA116856R1001 1.6

63 A2, A3  3 OS63GB03K 1SCA116745R1001 1.3

63 A2, A3  4 OS63GB04N1K 1SCA116746R1001 1.6

Including terminal bolt set

100 A2-A41) 3 OS100GB03K 1SCA116747R1001 1.5

100 A2-A41) 4 OS100GB04N1K 1SCA116748R1001 1.8

125 A2-A41) 3 OS125GB03K 1SCA116751R1001 1.5

125 A2-A41) 4 OS125GB04N1K 1SCA116752R1001 1.8

160 A2-A41) 3 OS160GB03K 1SCA116753R1001 1.5

160 A2-A41) 4 OS160GB04N1K 1SCA116754R1001 1.8

N1 = Non-fused switched neutral on the left side1) Max. fuse diameter 32 mm

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS32G...63G_K - OSV200BK -

OS100G...160G_K - OSV200BK M8X25

Ordering information, IECSwitch fuses, BS-type

OS32G...63GB03K

OS32G...63GB04N1K

OS100G...160GB03K

OS100G...160GB04N1K

Page 33: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 33

Front operated switch fuses with direct mount handleIncluding terminal bolt set, a black Test-OFF-ON plastic handle and shaft as standard. The handle is padlockable in the OFF-position.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

Including terminal bolt set

200 B1-B2 3 OS200B03K 1SCA022763R6950 3.3

250 B1-B3 3 OS250B03K 1SCA022763R6010 4.3

315 B1-B4 3 OS315B03K 1SCA022763R6520 7.0

400 B1-B4 3 OS400B03K 1SCA022763R6790 7.0

630 C1-C2 3 OS630B03K 1SCA108708R1001 13

800 C1-C3 3 OS800B03K 1SCA108713R1001 13

1250A1) D1 3 OS1250B03K 1SCA108715R1001 451) 1250A / AC-20…22A, 1000A / AC-23A

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS200_K - OSV200BK M8X25

OS250_K - OSV250DK M10X30

OS315…400_K - OSV400BK M10X30

OS630...800_K - OSV800DK M12X40

OS1250_K - OSV1250DK M12x50

Ordering information, IECSwitch fuses, BS-type

OS630B03K

Page 34: Switch fuses OS and OSM - ABB

34 Ordering information | Switch fuses OS and OSM

Side operated switch fuses with direct mount handleIncluding terminal bolt set (OS125G...160G), a black Test-ON-OFF plastic handle and shaft as standard. The handle is padlockable in the OFF-position.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Protected tunnel terminals, IP20.

32 A2, A3  3 OS32GBS30K 1SCA115918R1001  1.3

32 A2, A3  4 OS32GBS40N1K 1SCA115923R1001  1.6

63 A2, A3  3 OS63GBS30K 1SCA115924R1001  1.3

63 A2, A3  4 OS63GBS40N1K 1SCA115979R1001  1.6

Including terminal bolt set

125 A2-A41) 3 OS125GBS30K 1SCA116400R1001 1.5

125 A2-A41) 4 OS125GBS40N1K 1SCA115926R1001 1.8

160 A2-A41) 3 OS160GBS30K 1SCA115927R1001 1.5

160 A2-A41) 4 OS160GBS40N1K 1SCA115928R1001 1.8

N1 = Non-fused switched neutral on the left side 1) Max. diameter 32 mm

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS20F...32F_ (OS Mini) OXP6X70-V0 OHB65J6 -

OS32G...63G_K OXP6X42-TO OHB65D6 -

OS125G...160G_K OXP6X42-TO OHB65D6 M8X25

Ordering informationSwitch fuses, BS-type

OS32GBS30K

OS32GBS40N1K

OS125GBS30K

OS125GBS40N1K

Page 35: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 35

Side operated switch fuses with direct mount handleIncluding terminal bolt set, a black Test-ON-OFF plastic handle and shaft as standard. The handle is padlockable in the OFF-position.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

200 B1-B2 3 OS200BS30K 1SCA022870R7850 3.6

200 B1-B2 4 OS200BS40N2K 1SCA022870R8230 4.5

250 B1-B3 3 OS250BS30K 1SCA022870R8660 4.6

250 B1-B3 4 OS250BS40N2K 1SCA022870R9040 5.4

315 B1-B4 3 OS315BS30K 1SCA022870R9470 7.5

315 B1-B4 4 OS315BS40N2K 1SCA022870R9800 9.5

400 B1-B4 3 OS400BS30K 1SCA022871R0210 7.5

400 B1-B4 4 OS400BS40N2K 1SCA022871R0640 9.5

630 C1-C2 3 OS630BS30K 1SCA108148R1001 14.1

630 C1-C2 4 OS630BS40N2K 1SCA108151R1001 17

800 C1-C3 3 OS800BS30K 1SCA108084R1001 14.1

800 C1-C3 4 OS800BS40N2K 1SCA108087R1001 17

N2 = Non-fused switched neutral on the right side

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS200_K OXP6X42-TO OHB65D6 M8x25

OS250_K OXP6X42-TO OHB65D6 M10x30

OS315...400_K OXP12X47-TO OHB95D12 M10x30

OS630…800_K OXP12X59-TO OHB145D12 M12x40

Ordering information, IECSwitch fuses, BS-type

OS200...250BS30K

OS200...250BS40N2K

Page 36: Switch fuses OS and OSM - ABB

36 Ordering information | Switch fuses OS and OSM

Special connected switch fuses, back in, back out connection (BB)Including terminal bolt set, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

125 A2…A41) 3 OS125GB03BBP 1SCA120783R1001 2.3

125 A2…A41) 4 OS125GB04BBN1P 1SCA122597R1001 2.7

160 A2…A41) 3 OS160GB03BBP 1SCA120657R1001 2.3

160 A2…A41) 4 OS160GB04BBN1P 1SCA122598R1001 2.7

200 B1…B22) 3 OS200B03BBP 1SCA102082R1001 3.3

200 B1…B22) 4 OS200B04BBN2P 1SCA102123R1001 4.2

250 B1…B32) 3 OS250B03BBP 1SCA102168R1001 4.3

250 B1…B32) 4 OS250B04BBN2P 1SCA102164R1001 5.1

315 B1…B43) 3 OS315B03BBP 1SCA102222R1001 7.1

315 B1…B43) 4 OS315B04BBN2P 1SCA102225R1001 9.1

400 B1…B43) 3 OS400B03BBP 1SCA102252R1001 7.1

400 B1…B43) 4 OS400B04BBN2P 1SCA102248R1001 9.11) Max fuse body dia 32 mm2) Max fuse body dia 52 mm3) Max fuse body dia 62 mm N1 = Non-fused switched neutral on the left sideN2 = Non-fused switched neutral on the right side

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS125G...160G_P OXP6X161 OHB65J6 M8x25

OS200_P OXP6X210 OHB65J6 M8x25

OS250_P OXP6X210 OHB65J6 M10x30

OS315...400_P OXP12X250 OHB95J12 M10x30

Ordering information, IECSwitch fuses, BS-type

OS125...160GB03BBP

OS200...400B03BBP

OS250...400B04BBN2P

Page 37: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 37

Special connected switch fuses, left in, right out connection (LR)Including terminal bolt set, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths. Terminal angles for side terminals are accessories and are not included in standard delivery.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism between the poles

125 A2…A41) 3 OS125GB12LRP 1SCA120258R1001 2.9

125 A2…A41) 3 OS125GB21LRP 1SCA120261R1001 2.9

125 A2…A41) 4 OS125GB22LRP 1SCA120265R1001 3.7

160 A2…A41) 3 OS160GB12LRP 1SCA120271R1001 2.9

160 A2…A41) 3 OS160GB21LRP 1SCA120273R1001 2.9

160 A2…A41) 4 OS160GB22LRP 1SCA120277R1001 3.7

200 B1…B22) 3 OS200B12LRP 1SCA022854R2910 6.2

200 B1…B22) 3 OS200B21LRP 1SCA022854R3050 6.2

200 B1…B22) 4 OS200B22LRP 1SCA022854R4290 9.1

250 B1…B32) 3 OS250B12LRP 1SCA022854R5690 6.2

250 B1…B32) 3 OS250B21LRP 1SCA022854R5850 6.2

250 B1…B32) 4 OS250B22LRP 1SCA022854R7210 9.1

315 B1…B43) 3 OS315B12LRP 1SCA022854R8790 9.6

315 B1…B43) 3 OS315B21LRP 1SCA022854R8870 9.6

315 B1…B43) 4 OS315B22LRP 1SCA022855R0000 12.8

400 B1…B43) 3 OS400B12LRP 1SCA022855R1400 9.6

400 B1…B43) 3 OS400B21LRP 1SCA022855R1580 9.6

400 B1…B43) 4 OS400B22LRP 1SCA022855R2710 12.81) Max fuse body dia 32 mm2) Max fuse body dia 52 mm3) Max fuse body dia 62 mm

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS125G...160G_P OXP6X161 OHB65J6 M8x25

OS200...250_P OXP6X210 OHB65J6 M8x16

OS315...400_P OXP12X250 OHB95J12 M8x16

Ordering information, IECSwitch fuses, BS-type

OS125G...160GB12LRP

OS200...250B12LRP

OS125GB21LRP

OS125GB22LRP

Page 38: Switch fuses OS and OSM - ABB

38 Ordering information | Switch fuses OS and OSM

Ordering information, IECSwitch fuses, NFC-type

Front operated switch fusesIncluding terminal bolt set in OS125G, a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

Protected tunnel terminals, IP20

50 14x51 2 OS50GF02P 1SCA118345R1001 1.0

50 14x51 3 OS50GF03P 1SCA115492R1001 1.3

50 14x51 4 OS50GF04N1P 1SCA115495R1001 1.6

50 14x51 4 OS50GF04FP 1SCA115498R1001 1.6

Including terminal bolt set

125 22x58 2 OS125GF02P 1SCA116727R1001 1.2

125 22x58 3 OS125GF03P 1SCA115602R1001 1.5

125 22x58 4 OS125GF04N1P 1SCA115888R1001 1.8

125 22x58 4 OS125GF04FP 1SCA115606R1001 1.8

F = Fused switched neutralN1 = Non-fused switched neutral on the left side

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS25FF…32FF_ (OS Mini) OXP6X150 OHB65J6 -

OS50G_P OXP6X161 OHB45J6 -

OS125G_P OXP6X161 OHB65J6 M8X25

OS50GF04FP

Page 39: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 39

Ordering information, IECSwitch fuses, NFC-type

Side operated switch fuses with pistol handleIncluding a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, Nema type 1, 3R, 12, padlockable in the OFF-position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Shaft mounting depths measured from the left side of the switch, 3-pole: H=154…166 mm

and 4 pole: H=189…201 mm. Protected tunnel terminals, IP20.

25 10x38 3 OS25FFS3010 1SCA108639R1001 0.7

25 10x38 3 OS25FFS3010-2 1SCA108808R1001 0.7

F = Fused switched neutral

Side operated switch fuses with direct mount handleIncluding terminal bolt set (OS125G), a black Test-ON-OFF plastic handle and shaft as standard. The handle is padlockable in the OFF-position.

Rated op.

current

AC-20...23A No. Weight/

≤ 690V Fuse of unit

[A] size poles Type Order number [kg]

Protected tunnel terminals, IP20.

50 14x51  3 OS50GFS30K 1SCA116404R1001 1.3

50 14x51  4 OS50GFS40N1K 1SCA116013R1001 1.6

50 14x51  4 OS50GFS40FK 1SCA116425R1001 1.6

Including terminal bolt set

125 22x58  3 OS125GFS30K 1SCA115944R1001 1.5

125 22x58  4 OS125GFS40N1K 1SCA115945R1001 1.8

125 22x58  4 OS125GFS40FK 1SCA115946R1001 1.8

F = Fused switched neutralN1 = Non-fused switched neutral on the left side

Shafts and handles included as standard

Suitable for switches Included shaft Included handle Incl. terminal bolts

OS50G_K OXP6X42-TO OHB65D6 -

OS125G_K OXP6X42-TO OHB65D6 M8X25

OS50GFS40FK

OS125GFS40FK

Page 40: Switch fuses OS and OSM - ABB

40 Ordering information | Switch fuses OS and OSM

Ordering information, UL/CSASwitch fuses, CC and J types

Front operated fusible disconnect switches

Ampere No. Weight/

rating Fuse of unit

[A] size poles Type Order number [kg]

Mechanism between the poles

Protected tunnel terminals, IP20, cable size 0.5…10 mm2, (AWG 18 - 8).

30 CC, 30A 3 OS30FACC12 1SCA108813R1001 0.7

30 CC, 30A 4 OS30FACC22F 1SCA108819R1001 0.9

30 J, 30A 3 OS30FAJ12 1SCA108824R1001 0.7

30 J, 30A 4 OS30FAJ22F 1SCA108829R1001 0.8

Protected tunnel terminals, IP20, cable size 2.5…25 mm2 (AWG 14 - 4).

60 J, 60A 3 OS60GJ12 1SCA122981R1001 1.3

60 J, 60A 4 OS60GJ22F 1SCA115468R1001 1.6

Including terminal bolt set

100 J, 100A 3 OS100GJ12 1SCA115665R1001 2.2

100 J, 100A 4 OS100GJ22F 1SCA115668R1001 2.5

Mechanism at the end of the switch fuse

Protected tunnel terminals, IP20, cable size 2.5…25 mm2 (AWG 14 - 4).

60 J, 60A 3 OS60GJ03 1SCA115866R1001 1.3

60 J, 60A 4 OS60GJ04F 1SCA115445R1001 1.6

Including terminal bolt set

100 J, 100A 3 OS100GJ03 1SCA115436R1001 2.2

100 J, 100A 4 OS100GJ04F 1SCA115438R1001 2.5

F = Fused switched neutral

Recommended shafts and handles

Suitable for switches Shaft Handle Terminal bolts

OS30FA (OS Mini) OXP6X150 OHB65J6 -

OS60G OXP6X161 OHB45J6 -

OS100G OXP6X161 OHB65J6 M8X25

OS60GJ12

OS100GJ12

OS60GJ22F

OS100GJ22F

OS100GJ03

Page 41: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 41

Ordering information, UL/CSASwitch fuses, J and L types

Front operated fusible disconnect switchesIncluding terminal bolt set.

Ampere No. Weight/

rating Fuse of unit

[A] size poles Type Order number [kg]

Mechanism at the end of the switch fuse

Including terminal bolt set

200 J/200A 2 OS200J02 1SCA107591R1001 2.1

200 J/200A 3 OS200J03 1SCA022733R6130 3.1

200 J/200A 4 OS200J04F 1SCA022758R9340 4.0

400 J/400A 2 OS400J02 1SCA107592R1001 5.0

400 J/400A 3 OS400J03 1SCA022755R0810 6.8

400 J/400A 4 OS400J04F 1SCA022755R3660 8.6

600 J/600A 2 OS600J02 1SCA107593R1001 10.0

600 J/600A 3 OS600J03 1SCA022825R8610 13.0

600 J/600A 4 OS600J04F 1SCA022839R3900 15.9

800 L/800A 2 OS800L02 1SCA116920R1001 9.8

800 L/800A 3 OS800L03 1SCA022825R9760 13.0

800 L/800A 4 OS800L04F 1SCA022839R5350 15.9

1200 L/1200A 2 OS1200L02 1SCA116924R1001 37

1200 L/1200A 3 OS1200L03 1SCA105467R1001 45

1200 L/1200A 4 OS1200L04F 1SCA105465R1001 54

F = Fused switched neutral

Recommended shafts and handles

Suitable for switches Shaft Handle Terminal bolts

OS200 OXP6X210 OHB65J6 M8X25

OS400 OXP12X250 OHB95J12 M10X30

OS600...800 OXP12X280 OHB145J12 M12X40

OS1200 OXP12X395 OHB274J12 M12X50

OS200J02

OS400J03

OS400J04F

OS800L04F

OS600J02

Page 42: Switch fuses OS and OSM - ABB

42 Ordering information | Switch fuses OS and OSM

Ordering information, UL/CSASwitch fuses, CC and J types

Side operated fusible disconnect switches

Ampere No. Weight/

rating Fuse of unit

[A] size poles Type Order number [kg]

Protected tunnel terminals, IP20.

30 CC, 30A 3 OS30FACCS30 1SCA108822R1001 0.7

30 J, 30A 3 OS30FAJS30 1SCA108834R1001 0.8

60 J, 60A 3 OS60GJS30 1SCA116051R1001 1.3

60 J, 60A 4 OS60GJS40F 1SCA115970R1001 1.7

Including terminal bolt set

100 J, 100A 3 OS100GJS30 1SCA115971R1001 2.3

100 J, 100A 4 OS100GJS40F 1SCA115972R1001 2.7

F = Fused switched neutral

Recommended shafts and handles

Suitable for switches Shaft Handle Terminal bolts

OS30FA (OS Mini) OXP6X70 OHB65J6 -

OS60GJS OXP6X42-TO OHB65D6 -

OS100GJS OXP6X42-TO OHB65D6 M8X25

OS60GJS40F

OS100GJS30

Page 43: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 43

Ordering information, IECMotorized switch fuses OSM, DIN-type

Motorized switch fuses OSMIncluding a handle for manual operation, bolt kit with nut and washers for all terminals (100A…1250A), male connectors for control circuit and a handle and spare fuse storage clip. Type codes for motor voltage Ue = 220-240 VAC

Rated current No. Weight/

AC-20...23 Fuse of unit

≤ 690V size poles Type Order number [kg]

32 000 3 OSM32GD3M230C 1SCA116664R1001 7.0

32 000 4 OSM32GD4N2M230C 1SCA118822R1001 7.3

63 000 3 OSM63GD3M230C 1SCA116660R1001 7.0

63 000 4 OSM63GD4N2M230C 1SCA118865R1001 7.3

125 000,00 3 OSM125GD3M230C 1SCA116674R1001 7.6

125 000,00 4 OSM125GD4N2M230C 1SCA118828R1001 7.9

160 000,00 3 OSM160GD3M230C 1SCA116673R1001 7.6

160 000,00 4 OSM160GD4N2M230C 1SCA118831R1001 7.9

200 0 3 OSM200D3M230C 1SCA104284R1001 9.6

200 0 3+N OSM200D3N3M230C 1SCA104282R1001 9.8

200 0 4 OSM200D4N2M230C 1SCA118836R1001 10.7

250 0-1 3 OSM250D3M230C 1SCA104295R1001 10.4

250 0-1 3+N OSM250D3N3M230C 1SCA104297R1001 10.5

250 0-1 4 OSM250D4N2M230C 1SCA118838R1001 11.2

400 0-2 3 OSM400D3M230C 1SCA104315R1001 14.8

400 0-2 3+N OSM400D3N3M230C 1SCA104317R1001 15.1

400 0-2 4 OSM400D4N2M230C 1SCA118842R1001 16.7

630 3 3 OSM630D3M230C 1SCA104518R1001 34

630 3 3+N OSM630D3N3M230C 1SCA104533R1001 35

630 3 4 OSM630D4N2M230C 1SCA118846R1001 38

800 3 3 OSM800D3M230C 1SCA104522R1001 34

800 3 3+N OSM800D3N3M230C 1SCA104534R1001 35

800 3 4 OSM800D4N2M230C 1SCA118847R1001 38

1250 4 3 OSM1250D3M230C 1SCA112549R1001 55

1250 4 3+N OSM1250D3N3M230C 1SCA112547R1001 56

1250 4 4 OSM1250D4N2M230C 1SCA118850R1001 65

1250 4a 3 OSM1250DA3M230C 1SCA112546R1001 55

1250 4a 3+N OSM1250DA3N3M230C 1SCA112544R1001 56

1250 4a 4 OSM1250DA4N2M230C 1SCA118851R1001 65

Number of poles: 3+N / Type: _N3_ = Include a detachable neutral link integrated into the mechanismN2 = Non-fused switched neutral on the right sideAvailable on request: F = Fused switched neutral

Handles and bolt kits included as standard

Suitable for switch fuses Handle+shaft kit Bolt kit

OSM32…63 OTV250EMK -

OSM100…200 OTV250EMK M8x25

OSM250 OTV250EMK M10X30

OSM400 OTV400EMK M10X30

OSM630…800 OTV800EMK M12X40

OSM1250 OTV1000EMK M12X50

OSM63GD3M230C

OSM160GD3M230C

OSM200D4N2M230C

OSM400D3M230C

OSM800D3M230C

OSM1250D3M230C

Page 44: Switch fuses OS and OSM - ABB

44 Ordering information | Switch fuses OS and OSM

Ordering information, IECMotorized switch fuses OSM, BS-type

Motorized switch fuses OSMIncluding a handle for manual operation, bolt kit with nut and washers for all terminals (100A…1250A), male connectors for control circuit and a handle and spare fuse storage clip. Type codes for motor voltage Ue = 220-240 VAC.

Rated current No. Weight/

AC-20...23 Fuse of unit

≤ 690V size poles Type Order number [kg]

32 A2-A3 3 OSM32GB3M230C 1SCA116662R1001 7.0

32 A2-A3 4 OSM32GB4N1M230C 1SCA118775R1001 7.3

63 A2-A3 3 OSM63GB3M230C 1SCA116657R1001 7.0

63 A2-A3 4 OSM63GB4N1M230C 1SCA118776R1001 7.3

100 A2-A4 3 OSM100GB3M230C 1SCA116679R1001 7.6

100 A2-A4 4 OSM100GB4N1M230C 1SCA118779R1001 7.9

125 A2-A4 3 OSM125GB3M230C 1SCA116677R1001 7.6

125 A2-A4 4 OSM125GB4N1M230C 1SCA118780R1001 7.9

160 A2-A4 3 OSM160GB3M230C 1SCA116670R1001 7.6

160 A2-A4 4 OSM160GB4N1M230C 1SCA118781R1001 7.9

200 B1-B2 3 OSM200B3M230C 1SCA104272R1001 9.6

200 B1-B2 3+N OSM200B3N3M230C 1SCA104323R1001 9.8

200 B1-B2 4 OSM200B4N1M230C 1SCA118784R1001 10.7

250 B1-B3 3 OSM250B3M230C 1SCA104287R1001 10.4

250 B1-B3 3+N OSM250B3N3M230C 1SCA104290R1001 10.5

250 B1-B3 4 OSM250B4N1M230C 1SCA118785R1001 11.2

315 B1-B4 3 OSM315B3M230C 1SCA104303R1001 14.8

315 B1-B4 3+N OSM315B3N3M230C 1SCA104306R1001 15.1

315 B1-B4 4 OSM315B4N1M230C 1SCA118788R1001 16.7

400 B1-B4 3 OSM400B3M230C 1SCA104310R1001 14.8

400 B1-B4 3+N OSM400B3N3M230C 1SCA104312R1001 15.1

400 B1-B4 4 OSM400B4N1M230C 1SCA118789R1001 16.7

630 C1-C2 3 OSM630B3M230C 1SCA104516R1001 34

630 C1-C2 3+N OSM630B3N3M230C 1SCA104535R1001 35

630 C1-C2 4 OSM630B4N1M230C 1SCA118791R1001 38

800 C1-C3 3 OSM800B3M230C 1SCA104520R1001 34

800 C1-C3 3+N OSM800B3N3M230C 1SCA104536R1001 35

800 C1-C3 4 OSM800B4N1M230C 1SCA118792R1001 38

1250 D1 3 OSM1250B3M230C 1SCA112552R1001 55

1250 D1 3+N OSM1250B3N3M230C 1SCA112550R1001 56

1250 D1 4 OSM1250B4N1M230C 1SCA118795R1001 65

Number of poles: 3+N / Type: _N3_ = Include a detachable neutral link integrated into the mechanismN1 = Non-fused switched neutral on the left sideAvailable on request: F = Fused switched neutral, N2 = Non-fused switched neutral on the right side

Handle and bolt kits included as standard

Suitable for switch fuses Handle+shaft kit Bolt kit

OSM32…63 OTV250EMK -

OSM100…200 OTV250EMK M8x25

OSM250 OTV250EMK M10X30

OSM315…400 OTV400EMK M10X30

OSM630…800 OTV800EMK M12X40

OSM1250 OTV1000EMK M12X50

OSM100GB3M230C

OSM250B3N3M230C

OSM250B4N1M230C

OSM315B3N3M230C

Page 45: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Accessories, selection overview 45

S07

019

56

43

1

89

2

4

7

3

4

10

AccessoriesSelection overview

1 Switch fuse | 2 Extended shaft | 3 Mounting frame for auxiliary contact | 4 Auxiliary contact | 5 Fuse monitor | 6 Detachable neutral link | 7 Handle knob | 8 Pistol type handle | 9 Blown fuse indicator | 10 Conversion kit: 6/8-pole, C/O, mech. interlock

OS16...OS40 (OS Mini)

OS32G...OS63G

1 Switch fuse | 2 Extended shaft | 3 Module for auxiliary contacts | 4 Auxiliary contact | 5 Fuse monitor | 6 Pistol type handle | 7 Direct mounted handle | 8 Blown fuse indicator | 9 Interlocks, mechanical & electrical | 10 Detachable neutral link | 11 Conversion kit: 6/8-pole, C/O, bypass, mech. interlock | 12 DIN rail mounting kit

4

8

5

3

1

6 7

2

910

11

12

S04

135

Page 46: Switch fuses OS and OSM - ABB

46 Accessories, selection overview | Switch fuses OS and OSM

OS100G...OS1250_

OSM32G...OSM1250

1 Switch fuse | 2 Extended shaft | 3 Terminal clamp | 4 Fourth pole | 5 Terminal shroud | 6 Module for auxiliary contacts | 7 Auxiliary contact | 8 Fuse monitor | 9 Pistol type handle | 10 Direct mounted handle | 11 Detachable neutral link | 12 Interlocks, mechanical & electrical | 13 Blown fuse indicator | 14 Conversion kit: 6/8-pole, C/O, bypass, mech. interlock | 15 DIN rail mounting kit (only for OS100G...160G_)

1 Motor operator | 2 Terminal clamp | 3 Terminal shroud | 4 Auxiliary contact | 5 Fuse monitor | 6 Detachable neutral link | 7 Blown fuse indicator | 8 Storage for handle and fuses

13

15

8

7

6

1

2

4

109

11 12

3

5 14

S04

134

5

1

2

6

4

3

S07

018

8

7

Page 47: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 47

Ordering informationAccessories

Pistol handles for front operated switch fuses

Plastic pistol handles, IP 65, Nema type 1, 3R, 12Padlockable with 3 padlocks in the OFF-position, door interlock in the ON-position. Screw fixingfrom the back side of the handle ensures double insulation.

Handle Weight/

length unit

Colour [mm] Type Order number [kg]

For shaft diameter 6 mm (for OSMini and OS32...250)

Black and red-yellow: I-O/ON-OFF, grey: I-O.

Black 45 OHB45J6 1SCA022380R8770 0.12

Red-yellow 45 OHY45J6 1SCA022380R8930 0.12

Grey 45 OHG45J6 1SCA022380R8850 0.12

Black 65 OHB65J6 1SCA022380R9660 0.12

Red-yellow 65 OHY65J6 1SCA022380R9820 0.12

Grey 65 OHG65J6 1SCA022380R9740 0.12

Black 80 OHB80J6 1SCA022381R0240 0.14

Black and red-yellow: Test/I-O/ON-OFF, grey: Test/I-O.

Black 45 OHB45J6T 1SCA109870R1001 0.12

Black 65 OHB65J6T 1SCA022399R8110 0.12

Red-yellow 65 OHY65J6T 1SCA022456R9540 0.12

Grey 65 OHG65J6T 1SCA022456R9620 0.12

Black 80 OHB80J6T 1SCA022399R8290 0.14

For shaft diameter 12 mm (for OS315...400)

Black and red-yellow: I-O/ON-OFF, grey: I-O.

Black 95 OHB95J12 1SCA022381R0830 0.16

Red-yellow 95 OHY95J12 1SCA022381R1050 0.16

Grey 95 OHG95J12 1SCA022381R0910 0.16

Indication: Test-OFF-ON/Test-O-I

Black 95 OHB95J12T 1SCA022736R1750 0.16

Red-yellow 95 OHY95J12T 1SCA022736R1910 0.16

For shaft diameter 12 mm (for OS630...800)

Black and red-yellow: I-O/ON-OFF, grey: I-O.

Black 125 OHB125J12 1SCA022381R1560 0.16

Red-yellow 125 OHY125J12 1SCA022381R1720 0.16

Grey 125 OHG125J12 1SCA022381R1640 0.16

Black 145 OHB145J12 1SCA022381R2110 0.17

Red-yellow 145 OHY145J12 1SCA022381R2370 0.17

Grey 145 OHG145J12 1SCA022381R2290 0.17

Black 175 OHB175J12 1SCA022381R2450 0.18

Red-yellow 175 OHY175J12 1SCA022381R2700 0.18

Grey 175 OHG175J12 1SCA022381R2610 0.18

Indication: Test-OFF-ON/Test-O-I

Black 125 OHB125J12T 1SCA022652R2220 0.16

Red-yellow 125 OHY125J12T 1SCA022652R2310 0.16

Black 145 OHB145J12T 1SCA022652R2570 0.17

Red-yellow 145 OHY145J12T 1SCA022652R2650 0.17

Black 175 OHB175J12T 1SCA022708R0740 0.18

- Door interlocking in the ON-position means that the door cannot be opened, when the handle is in the ON-position. This can be defeated to allow authorized personnel access for inspection. - Handles padlockable in all positions and NEMA4/4X handles are available on request.

OHB65J6

OHY65J6

OHG65J6

OHB95J12

OHY95J12T

OHB125J12

Page 48: Switch fuses OS and OSM - ABB

48 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Optional handles for front operated switch fuses

Plastic pistol handles, IP 65, Nema type 1, 3R, 12Padlockable with 3 padlocks in the OFF-position, door interlock in the ON-position. Screw fixing from the back side of the handle ensures double insulation.

Handle Weight/

length unit

Colour [mm] Type Order number [kg]

For shaft diameter 12 mm (for OS1200...1250)

Black and red-yellow: I-O/ON-OFF.

Black 274 OHB274J12 1SCA115920R1001 0.54

Red-yellow 274 OHY274J12 1SCA115919R1001 0.54

Black 330 OHB330J12 1SCA115922R1001 0.58

Red-yellow 330 OHY330J12 1SCA115921R1001 0.58

Black 2x150 OHB150J12P 1SCA022865R9430 0.17

Red-yellow 2x150 OHY150J12P 1SCA101586R1001 0.17

Black 2x200 OHB200J12P 1SCA022865R9510 0.40

Red-yellow 2x200 OHY200J12P 1SCA101587R1001 0.40

Indication: Test-OFF-ON/Test-O-I

Black 274 OHB274J12T 1SCA120250R1001 0.54

Black 330 OHB330J12T 1SCA120252R1001 0.58

Black 2x200 OHB200J12PT 1SCA106510R1001 0.40

Red-yellow 2x200 OHY200J12PT 1SCA111512R1001 0.40

- Door interlocking in the ON-position means that the door cannot be opened, when the handle is in the ON-position. This can be defeated to allow authorized personnel access for inspection. - Handles padlockable in all positions and NEMA4/4X handles are available on request.

Stainless steel pistol handles, IP66, NEMA 4XPadlockable with 3 padlocks in the OFF-position, door interlock in the ON-position, indication: I-O/ON-OFF

Handle Weight/

length unit

Colour [mm] Type Order number [kg]

For shaft diameter 6 mm (for OSMini and OS32...250)

Metallic 65 OHM65L6 1SCA022739R1070 0.73

For shaft diameter 12 mm

Metallic 125 OHM125L12 1SCA022739R1150 0.76

Metallic 175 OHM175L12 1SCA022739R1230 0.83

Metallic 275 OHM275L12 1SCA022832R4840 0.96

Metallic pistol handlesPadlockable with 3 padlocks in OFF-position, door interlock in the ON-position.

For shaft diameter 12 mm

Black 1-0 220 YASDA 7 1SCA022071R3010 0.70

Black ON-OFF 220 YASDA 8 1SCA022071R3270 0.70

Black I-0 320 YASDA35 1SCA104400R1001 0.80

OHB274/330J12

OHM_

YASDA_

OHY274J12

Page 49: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 49

Ordering informationAccessories

Pistol handles for side operated switch fuses

Plastic pistol handles, IP 65, Nema type 1, 3R, 12For mounting on the side of the enclosure. Padlockable with three padlocks in the OFF-position, door interlock in the ON-position, IP 65. The position indications are rotated 90°. If the handle is mounted on the front of the door, a standard handle can be used as well.

Handle Weight/

length unit

Colour [mm] Type Order number [kg]

For shaft diameter 6 mm

Plastic handles, black and red-yellow: I-O/ON-OFF, grey: I-O.

Black 65 OHB65J6E00S 1SCA022382R9850 0.12

Red-yellow 65 OHY65J6E00S 1SCA022382R9930 0.12

Grey 65 OHG65J6E00S 1SCA022383R4510 0.12

Plastic handles, black and red-yellow: Test/I-O/ON-OFF, grey: Test/I-O.

Black 65 OHB65J6TE00S 1SCA109016R1001 0.12

Red-yellow 65 OHY65J6TE00S 1SCA022688R0140 0.12

Grey 65 OHG65J6TE00S 1SCA109014R1001 0.12

For shaft diameter 12 mm

Plastic handles, indication I-O/ON-OFF

Black 145 OHB145J12E00S 1SCA022679R9700 0.17

- Door interlocking in the ON-position means that the door cannot be opened, when the handle is in the ON-position. This can be defeated to allow authorized personnel access for inspection. - Handles padlockable in all positions are available on request.

Extension ring for pistol handles

Suitable Weight

for unit

handles Colour Type Order number [kg]

OHB_ Black OHZX14 1SCA022851R6590 0.06

OHB65J6E00S

OHY65J6E00S

OHZX14

Page 50: Switch fuses OS and OSM - ABB

50 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Direct mount handles for front operated switch fusesPanel board handle, can be padlocked in the OFF-position. Includes a special shaft. The handle can also be used with a standard shaft as padlocking device.

Suitable Weight/

for unit

switches Colour Type Order number [kg]

Suitable for OS Mini

Indication: I-O/ON-OFF/TEST Padlockable with 2 padlocks in the OFF- and Test-positions when the door is open. Max. bail dia 8 mm.

OS20F…40F_ Black OHBS5 1SCA109015R1001 0.05

Suitable for OS 32G...1250

Indication: Test OFF-ON/Test O-I indication Padlockable with three padlocks in the OFF-position, optionally also in the ON-position.

Includes shaft and mechanism cover.

OS32G...160G, OS200J Black OSV200BK 1SCA022779R7530 0.14

OS200B/J_K Red-yellow OSVY200BK 1SCA022779R7700 0.14

OS200D…250D/B_K Black OSV250DK 1SCA022763R3510 0.16

OS200D…250D/B_K Red-yellow OSVY250DK 1SCA022778R6500 0.16

OS400D_K Black OSV400DK 1SCA022763R4230 0.34

OS400D_K Red-yellow OSVY400DK 1SCA022779R5590 0.34

OS315…400B/J_K Black OSV400BK 1SCA022763R3930 0.33

OS315…400B/J_K Red-yellow OSVY400BK 1SCA022779R5830 0.33

OS600…800_K Black OSV800DK 1SCA107794R1001 1.1

OS600…800_K Red-yellow OSVY800DK 1SCA108703R1001 1.1

OS1200...OS1250_K Black OSV1250DK 1SCA107797R1001 1.5

OS1200...OS1250_K Red-yellow OSVY1250DK 1SCA108702R1001 1.5

Direct mount handles for side operated switch fusesPanel board handle, can be padlocked in the OFF-position. Includes a special shaft. The handle can also be used with a standard shaft as padlocking device.

Suitable Weight/

for unit

switches Colour Type Order number [kg]

Suitable for OS Mini

Padlockable with three padlocks in the OFF- position when the door is open. Max. bail dia 6 mm.

OS20F…40F_ Black OHB4 1SCA022439R4050 0.05

Fuse replacement handles

For Weights/

DIN-fuse unit

sizes Type Order number [kg]

000,00,1,2,3 OFAE506 1SCA128175R1001 0.2

OSV250DK

OSV400DK

OSV1250DK

OHB4

OFAE506

Page 51: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 51

Ordering informationAccessories

Extended shafts

Shaft Front Side Weight/

length operated operated unit

[mm] H [mm] H [mm] Type Order number [kg]

For OS 16...35 (Mini)2), shaft diameter 6 mm

150 135...210 154...166 OXP6X1505) 1SCA022295R5600 0.05

170 155...230 174...186 OXP6X170 1SCA108224R1001 0.05

265 250...325 269...281 OXP6X265 1SCA108225R1001 0.08

400 385...460 404...416 OXP6X400 1SCA108226R1001 0.12

150 135...210 154...166 OXP6X150-451) 1SCA022294R4400 0.05

170 155...230 174...186 OXP6X170-451) 1SCA108227R1001 0.05

265 380...460 269...281 OXP6X265-451) 1SCA108228R1001 0.08

400 380...460 404...416 OXP6X400-451) 1SCA108229R1001 0.12

For OS 40 (Mini)2), shaft diameter 6 mm

150 135...210 235...243 OXP6X1505) 1SCA022295R5600 0.05

170 155...230 255...363 OXP6X170 1SCA108224R1001 0.05

265 250...325 352...360 OXP6X265 1SCA108225R1001 0.08

400 385...460 487...495 OXP6X400 1SCA108226R1001 0.12

150 135...210 235...243 OXP6X150-451) 1SCA022294R4400 0.05

170 155...230 255...363 OXP6X170-451) 1SCA108227R1001 0.05

265 250...325 352...360 OXP6X265-451) 1SCA108228R1001 0.08

400 385...460 487...495 OXP6X400-451) 1SCA108229R1001 0.12

For OS 32G...63G4) , shaft diameter 6 mm

63 161…167 OXP6X63 1SCA111010R1001 0.02

90 188…194 OXP6X90 1SCA022064R1180 0.03

130 127…1746) 228…234 OXP6X130 1SCA022057R0570 0.04

161 138…205 OXP6X1613) 1SCA022067R1760 0.05

210 187…254 OXP6X210 1SCA022295R6080 0.06

290 267…334 OXP6X290 1SCA022042R6370 0.08

360 337…404 OXP6X360 1SCA022042R6530 0.10

430 407…474 OXP6X430 1SCA022056R6030 0.12

210 187…254 OXP6X210-451) 1SCA022294R4230 0.06

290 267…334 OXP6X290-451) 1SCA022304R4290 0.08

360 337…404 OXP6X360-451) 1SCA022341R4640 0.101) The shaft position is rotated 45 degrees 2) Side operated, 4-pole: add 36 mm 3) Included as standard in P-types 4) Side operated 3-pole OS60GJ: add 33mm, 4-pole types: OS32…63GD/GB: add 23.5 mm, OS60GJ: add 68mm 5) Included as standard in front operated types 6) OS32…63GB/GF: 115…174

OXP6X_

OXP_X_-45

Page 52: Switch fuses OS and OSM - ABB

52 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Extended shafts

Shaft Front Side Weight/

length operated operated unit

[mm] H [mm] H [mm] Type Order number [kg]

For OS100G...160G2), shaft diameter 6 mm

63 196…202 OXP6X63 1SCA111010R1001 0.02

90 223…229 OXP6X90 1SCA022064R1180 0.03

130 137…1744) 263…269 OXP6X130 1SCA022057R0570 0.04

161 138…205 OXP6X1613) 1SCA022067R1760 0.05

210 187…254 OXP6X210 1SCA022295R6080 0.06

290 267…334 OXP6X290 1SCA022042R6370 0.08

360 337…404 OXP6X360 1SCA022042R6530 0.10

430 407…474 OXP6X430 1SCA022056R6030 0.12

210 187…254 OXP6X210-451) 1SCA022294R4230 0.06

290 267…334 OXP6X290-451) 1SCA022304R4290 0.08

360 337…404 OXP6X360-451) 1SCA022341R4640 0.10

For OS 200...250 DIN-type, shaft diameter 6 mm

161 160...205 OXP6X161 1SCA022067R1760 0.05

210 189...254 OXP6X2103) 1SCA022295R6080 0.06

290 269...334 OXP6X290 1SCA022042R6370 0.08

For OS 200...250 BS-type, shaft diameter 6 mm

161 140…205 OXP6X161 1SCA022067R1760 0.05

210 189…254 OXP6X2103) 1SCA022295R6080 0.06

290 269…334 OXP6X290 1SCA022042R6370 0.08

For OS 315...400, shaft diameter 12 mm

250 230…325 OXP12X2503) 1SCA022325R6980 0.30

280 260…355 OXP12X280 1SCA022137R5140 0.30

325 305…400 OXP12X325 1SCA022042R5810 0.36

395 375…470 OXP12X395 1SCA022042R5990 0.43

465 445…540 OXP12X465 1SCA022042R6020 0.51

535 515…610 OXP12X535 1SCA022042R6110 0.591) The shaft position is rotated 45 degrees 2) Side operated 4-pole types: add 35mm 3) Included as standard in P-types 4) OS100GJ: 113…174, OS100GB…160GB: 121…174

OHP6X_

OHP_X_-45

OHP12X_

Page 53: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 53

Ordering informationAccessories

Extended shafts

Shaft Front Weight/

length operated unit

[mm] H [mm] H [mm] Type Order number [kg]

For OS 630...800, shaft diameter 12 mm

280 258...382 OXP12X2802) 1SCA022137R5140 0.30

325 303...427 OXP12X325 1SCA022042R5810 0.40

395 373...497 OXP12X395 1SCA022042R5990 0.50

465 443...567 OXP12X465 1SCA022042R6020 0.60

535 513...637 OXP12X535 1SCA022042R6110 0.70

280 258...382 OXP12X280-451) 1SCA022382R0800 0.30

325 303...427 OXP12X325-451) 1SCA022304R4450 0.40

For OS 1200...1250, shaft diameter 12 mm

395 366…4953) 371...5004) OXP12X3952) 1SCA022042R5990 0.43

465 436…5653) 441...5704) OXP12X465 1SCA022042R6020 0.51

535 506…6353) 441...5714) OXP12X535 1SCA022042R6110 0.591) The shaft position is rotated 45 degrees 2) Included as standard in front operated P-types 3) H with handle OH_274/330J12 4) H with handle OHB150/200J12P

Shaft extension socketFor extending the shaft of combination attachment.

Suitable for Weight/

shaft with diameter unit

[mm] Type Order number [kg]

12 OETLZX95 1SCA022083R5620 0.04

Adapters for extension socketAdapters to place inside of OETLZX 95 to connect shafts of different sizes.

Suitable for Weight/

shaft with diameter unit

[mm] Type Order number [kg]

6/6, 6/12 OETLZK19 1SCA022093R1850 0.02

OXP12X_

OXP12X250-45

OETLZX95

Page 54: Switch fuses OS and OSM - ABB

54 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Auxiliary contacts for OS20F_…40F_ (OS Mini)Units/type = 1 piece

Weight/

unit

Description Type Order number [kg]

Mounting to the switch mechanism

Change over contacts

Auxiliary/test contacts. Max. two change over contacts.

See function chart below OA4B1C 1SCA022193R0150 0.03

Single pole contacts

> 3 mm contact gap.

1 NO OA4B10 1SCA022276R9050 0.03

1 NC OA4B01 1SCA022276R9210 0.03

Mounting on the side of the switch

Mounting on the side of the switch with aux.contact frame OESAZX 169

1NO MCB-10 1SCA022150R5110 0.03

1NC MCB-01 1SCA022150R5370 0.03

Snap-on mounting on the switch, by using a frame OSZ4, IP20

NO contacts are provided with a positive opening feature.

Types _AU have gold plated contacts for harsh environments and low operating voltages.

1 NO OA1G10 1SCA022353R4970 0.03

1 NC OA3G01 1SCA022456R7410 0.03

1 NO OA1G10AU 1SCA022436R7910 0.03

1 NC OA3G01AU 1SCA022819R5260 0.03

Mounting frames for auxiliary contacts of OS20F_…40F_ (OS Mini)

Amount of Weight/

auxiliary contacts unit

Description [pcs] Type Order number [kg]

Frame for auxiliary contacts OA1G10 and OA3G01 and for fuse monitor

Mounting on the left side

of the switch

max. 6 OSZ4 1SCA022530R0200 0.06

Frame for MCB-_ auxiliary contacts. Not suitable for side operated switches

Mounting on the right side

of the switch

max. 6 OESAZX169 1SCA022196R9360 0.06

Function chart, change over contacts OA4B1C / OS Mini

Handle position Main contacts Aux./Test contacts N.O.

Test open closed

0 open open

I closed closed

OA4B10

OA3G01

OESAZX169

Page 55: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 55

Auxiliary contacts for OS/OSM32G...1250Types _AU have gold plated contacts for harsh environments and low operating voltages.

Suitable Weight/

for Protection unit

switches Description degree Type Order number [kg]

OS/OSM32G...1250 1NO IP20 OA1G10 1SCA022353R4970 0.03

OS/OSM32G...1250 1NC IP20 OA3G01 1SCA022456R7410 0.03

OS/OSM32G...1250 1NO IP20 OA1G10AU 1SCA022436R7910 0.03

OS/OSM32G...1250 1NC IP20 OA3G01AU 1SCA022819R5260 0.03

Mounting under the mechanism coverThe “test” contacts operate in ON- and OFF-positions as well as when the handle is turned to TEST-position = 45 degrees over the OFF-position. The “test tindication” contacts operate only when the handle is turned to TEST-position. See the function table below. The OA1G10 (N.O.) or OA3G01 (N.C.) auxiliary contact blocks can be used as standard auxiliary contacts, “test” or “test indication” contacts. The desired functions are achieved when an auxiliary contact block is installed in a specific place shown in the mounting instruction. In order to activate the “test” and “test indication” features, a handle with test function is required. See the optional handles, pages 60...48.

Function table of OS/OSM32G…1250 auxiliary contacts

Handle position Main contacts Aux./Test contacts N.O. Test indication contacts N.O

Test open closed closed

0 open open open

I closed closed open

Maximum number of contact blocks, “Aux./test” contacts and “test indication” contacts, see the table below. Standard versions include all except for N3-types, which are equipped with integrated neutral through the mechanism.

Ordering informationAccessories

Maximum number of auxiliary contacts under the mechanism cover

OS/OSM32G…250 OS/OSM315…800 OS/OSM1200…1250

Pole version Standard N3 Standard N3 Standard N3

Maximum number of contact blocks 4 0 8 4 12 8

Aux./Test contacts 4 0 4 2 81) 62)

Test indication contacts 2 0 4 2 4 2

For contact timing, see pages 106 and 107. 1) 6 aux/test contacts and 2 early operation aux./test contacts 2) 4 aux/test contacts and 2 early operation aux./test contacts

Mounting on the left side of the OS switch fuse:

Maximum 8 auxiliary contact blocks (N.O. or N.C.) with the OEA28 module. Side operated types: OS_S30..._S40 types only.Mounting on the right side of the OSM motorized switch fuse:

Maximum 4 auxiliary contact blocks (N.O. or N.C.), snap-on mounting.

OA3G01

OA3G01AU

Page 56: Switch fuses OS and OSM - ABB

56 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Performance data for auxiliary contacts according to IEC 60947-5-1

OA1G_, OA3G_

Ui/[V] 690

Uimp/[kV] 4

Pollution degree 3

Ith/[A] 16

Cable size 1…2 x 0,75…2,5 mm2

Maximum fuse 16 A/gG

NEMA A600, R300

Wire size 18 - 14AWG, 1 (2)

Module for auxiliary contacts for OS32...1250

Weight/

unit

Description Type Order number [kg]

Screw mounting to the left side of the switch OEA28 1SCA022714R8810 0.04

OA1G_, OA3G_

AC15 DC12 DC13

Ue /[V] Ie/[A] Ue/[V] Ie/[A] P/[W] Ie/[A] P/[W]

230 6 24 10 240 2 48

400 4 72 4 288 0.8 58

690 2 125 2 250 0.55 69

250 0.55 138 0.27 68

440 0.1 44

MCB_

IEC60947-5-1

Ui /[V] 690

Ith /[A] 10

AC12 AC15 DC13

Ie /[A] 24V 10 8 5

110V 10 8 1.1

220/240V 10 6 0.55

250V 4 0.55

380/415V 4

660/690V 2

NEMA A600, 10A, 600VAC

OA4_

EN61058-1

Ui /[V] 400

Ith /[A] 10

Ie 400V AC

10 (4) A, 10E3

6 (2,5) A, 50E3

NEMA 10 A, 125-250V AC, 1/4 HP

M3 Screw connection

OEA28

Page 57: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 57

Ordering informationAccessories

Mounting plate for auxiliary contactsMount on the switch mechanism, max. 3 auxiliary contacts.

Suitable

for

switches Type Order number

R: Mounting on the right side of the switch L: mounting on the left side of the switch

OS100G_...200G_ OEA30R 1SCA131817R1001

OS100G_...200G_ OEA30L 1SCA131816R1001

Fourth polesSnap-on mounting to the side of the switch (not suitable for OSM-types).

Suitable for Weight/

3-pole Mounting unit

switches side Type Order number [kg]

Fusible 4. poles

OS100GB...160GB Left/right OSP160GB 1SCA114769R1001 0.45

OS125GD...160GD Left/right OSP160GD 1SCA114768R1001 0.45

OS200B Left/right OSP200B 1SCA022735R9180 1.20

OS200D Left/right OSP200D 1SCA022735R8960 1.20

OS250B Left/right OSP250B 1SCA022770R4030 1.20

OS250D Left/right OSP250D 1SCA022735R9340 1.20

OS315B…400B Left/right OSP400B 1SCA022770R3140 2.00

OS400D Left/right OSP400D 1SCA022770R3220 2.00

OS630...800D Left/right OSP800D 1SCA100433R1001 4.20

OS630...800B Left/right OSP800B 1SCA100434R1001 4.20

OS1250D Left/right OSP1250D 1SCA107946R1001 7.20

OS1250DA Left/right OSP1250DA 1SCA112402R1001 7.20

OS1250B Left/right OSP1250B 1SCA107950R1001 7.20

Switched 4. poles

OS100G...160G Left/right OSP160GN 1SCA114770R1001 0.45

OS200_ Left/right OSP200N 1SCA022735R8700 1.20

OS250_ Left/right OSP250N 1SCA022735R9260 1.20

OS400_ Left/right OSP400N 1SCA022770R3490 1.20

OS630...800 Left/right OSP800N 1SCA100432R1001 4.40

OS1200...1250 Left/right OSP1250N 1SCA107943R1001 7.20

OSP200-400D

OSP160GN

OSP250N

OSP800N

Page 58: Switch fuses OS and OSM - ABB

58 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Neutral links

Weight/

H/W/D Mounting unit

Max. wire [mm] holes Type Order number [kg]

For OS/OSM 32G...160G Detachable, mounting onto the base plate or DIN-rail.

16 mm2 Cu 39/41/40 ø 4.2, distance 32 OSZ1 1SCA022481R3710 0.06

35 mm2 Cu 39/44/45 ø 4.2, distance 35 OSZ2 1SCA022481R3800 0.07

For OS/OSM 100G...1250Mounting with screws (included) onto either side of the switch (OXN250 to OS200...250) or on the base plate (OXN250...1250) according the table below.

Detachable, mounting on the switch

OS200...250 OXN250 1SCA022752R9950 0.40

Detachable, mounting on the base plate

OS/OSM32G...250 OXN250 1SCA022752R9950 0.40

OS/OSM315…400 OXN400 1SCA022770R3060 0.70

OS/OSM630…800 OXN800S 1SCA022831R4880 1.20

OS/OSM1250 OXN1250S 1SCA104163R1001 2.50

OSZ1

OXN250

OXN400

OXN800S

Page 59: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 59

Ordering informationAccessories

Solid links

Weight/

unit

Suitable for Type Order number [kg]

OS32GD...OS160GD OFAW00 1SCA022003R9680 0.08

OS200…250B, J OEZNL1 1SCA022723R7400 0.19

OS600J, 800…1200L OEZNL8 1SCA113998R1001 0.58

OS1250B OEZNL10 1SCA116437R1001 0.60

OS250 D OFAW1 1SCA022003R9760 0.15

OS400 D OFAW2 1SCA022003R9840 0.24

OS630/800 D OFAW3 1SCA022003R9920 0.28

Handle and spare fuse storage clip for OSMHandle and two spare fuses (for motor operator) can be stored on the OTVS_. OTVS_ can be installed on the left side of the motorized switch-fuse OSM_. Snap-on mounting, no tools required. On OSM1250, the size of the handle prevents the installation onto the switch frame. However, the handle clip can be separately installed on the panel frame and the fuse holder clip onto the switch frame.

Weight/

unit

Suitable for Type Order number [kg]

OSM32G...250 OTVS1 1SCA111413R1001 0.02

OSM315...1250 OTVS2 1SCA111414R1001 0.04

OTVS1

OTVS2

Phase barriersThe phase barriers designed for ABB Tmax T4-T5 MCCB’s can also be used for OS200…400 switch fuses. 3-pole switch fuses need 4 barriers and 4-pole switch fuses need 6 barriers for full protection. Cutting width of the phase barrier 55mm.

Suitable No. Height Units/

for of h type

switches poles [mm] Type Order number [pcs]

OS100G…OS200G 3 - OSB160/4 1SCA131820R1001 4

OS100G…OS200G 3 - OSB160/6 1SCA131821R1001 6

OS250 3 - OSB250/4 1SCA131822R1001 4

OS250 4 - OSB250/6 1SCA131823R1001 6

OS315, OS400 3 200 PB200 high 1SDA054972R1 4

OS315, OS400 4 200 PB200 high 1SDA054973R1 6

Page 60: Switch fuses OS and OSM - ABB

60 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Terminal shrouds

Units/ Weight/

Suitable for type unit

switches Description Type Order number [pcs] [kg]

Pack of single pole terminal shrouds

Snap-on mounting, grey plastic, IP 3X from front. Transparent shrouds available on request.

OS/OSM100G…160G Long type OSS160GG1L/3 1SCA114764R1001 3 0.08

OS/OSM100G…160G Short type OSS160GG1S/3 1SCA114766R1001 3 0.05

OS/OSM100G…160G Long type OSS160GG1L/4 1SCA114765R1001 4 0.11

OS/OSM100G…160G Short type OSS160GG1S/4 1SCA114767R1001 4 0.07

OS/OSM200 Long type OSS200G1L/3 1SCA022731R8910 3 0.09

OS/OSM200 Short type OSS200G1S/3 1SCA022732R0130 3 0.06

OS/OSM200 Long type OSS200G1L/4 1SCA022731R9040 4 0.12

OS/OSM200 Short type OSS200G1S/4 1SCA022732R0050 4 0.08

OS/OSM250 Long type OSS250G1L/3 1SCA022731R9390 3 0.09

OS/OSM250 Short type OSS250G1S/3 1SCA022731R9550 3 0.06

OS/OSM250 Long type OSS250G1L/4 1SCA022731R9470 4 0.12

OS/OSM250 Short type OSS250G1S/4 1SCA022731R9630 4 0.08

OS/OSM315...400 Long type OSS400G1L/3 1SCA022776R6650 3 0.18

OS/OSM315...400 Short type OSS400G1S/3 1SCA022776R6900 3 0.10

OS/OSM315...400 Long type OSS400G1L/4 1SCA022776R6730 4 0.25

OS/OSM315...400 Short type OSS400G1S/4 1SCA022776R7030 4 0.15

OS/OSM600...800 Long type OSS800G1L/3 1SCA022776R7200 3 0.53

OS/OSM600...800 Short type OSS800G1S/3 1SCA022776R7540 3 0.21

OS/OSM600...800 Long type OSS800G1L/4 1SCA022776R7380 4 0.70

OS/OSM600...800 Short type OSS800G1S/4 1SCA022776R7460 4 0.28

OS1200...1250/ OSM1250 Long type OSS1250G1L/3 1SCA107938R1001 3 0.76

OS1200...1250/ OSM1250 Short type OSS1250G1S/3 1SCA107939R1001 3 0.40

OS1200...1250/ OSM1250 Long type OSS1250G1L/4 1SCA107940R1001 4 1.00

OS1200...1250/ OSM1250 Short type OSS1250G1S/4 1SCA107941R1001 4 0.52

Terminal shrouds suitable for mechanisms with detachable integrated neutral (N3 versions)

OS/OSM100G…250_N3_ Long type OTS250G1L 1SCA022715R5340 1 0.03

OS/OSM100G…250_N3_ Short type OTS250G1S 1SCA022715R5260 1 0.02

OS/OSM315…400_N3_ Long type OSS250G1L 1SCA022727R5080 1 0.03

OS/OSM315…400_N3_ Short type OSS250G1S 1SCA022727R4940 1 0.02

OS/OSM630…800_N3_ Long type OTS800G1L 1SCA022776R7710 1 0.10

OS/OSM630…800_N3_ Short type OTS800G1S 1SCA022776R8010 1 0.06

OS1200...1250/OSM1250_N3_ Long type OTS1600G1L 1SCA106134R1001 1 0.20

OS1200...1250/OSM1250_N3_ Short type OTS1600G1S 1SCA102667R1001 1 0.12

Single pole terminal shroud for the fourth pole side terminals (LR-types)

IP20, snap-on mounting, grey plastic.

OS250_LR Short type OSS250G1SH/1 1SCA103500R1001 1 0.003

OS400_LR Short type OSS400G1SH/1 1SCA103503R1001 1 0.003

Please consult us when using OS600J...OS800L with OZXA-800 lugs

OSS200G1L

OSS200G1S

OSS250G1L

OSS800G1L

OSS250G1SH

OSS800G1S

Page 61: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 61

Ordering informationAccessories

OSS400G3LS

OEZXU14

Terminal shrouds

Three and four pole terminal shrouds for side terminals (LR types)IP20. Snap-on mounting, grey plastic.

No. Units/ Weight/

Suitable for of type unit

switches poles Remarks Type Order number [pcs] [kg]

OS100G...160G_LR 3 Long type OSS160GG3LS 1SCA121570R1001 1 0.01

OS100G...160G_LR 4 Long type OSS160GG4LS 1SCA121571R1001 1 0.01

OS200…400_ 3 Short type OSS400G3SS 1SCA100390R1001 1 0.01

OS200…400_ 3 Long type OSS400G3LS 1SCA100396R1001 1 0.01

OS200…400_ 4 Left side, short OSS400G4SSL 1SCA100392R1001 1 0.01

OS200…400_ 4 Left side, long OSS400G4LSL 1SCA100398R1001 1 0.01

OS200…400_ 4 Right side, short OSS400G4SSR 1SCA100394R1001 1 0.01

OS200…400_ 4 Right side, long OSS400G4LSR 1SCA100400R1001 1 0.01

Single pole shroud for terminal clampsSnap-on mounting, transparent plastic, IP 2X.

Suitable for Units/ Weight/

terminal type unit

clamps Type Order number [pcs] [kg]

OZXB2, 2L OZXB2K 1SCA022264R0010 3 0.06

OZXB3, 4 OZXB3K 1SCA022264R0440 3 0.18

OZXB5, 6 OZXB4K 1SCA022199R2850 3 0.24

OZXB7, 7L OZXB5K 1SCA022283R8040 3 0.15

Terminal angle for side terminals (LR types)Terminal angle extension bar for cable connections in upper or lower position. Including terminal bolts M10x30.

Units/ Weight/

Suitable for type unit

switches Type Order number [pcs] [kg]

OS100G...160G_LR, 3-pole OEZXU68/3 1SCA121380R1001 3

OS100G...160G_LR, 4-pole OEZXU68/4 1SCA121379R1001 4

OS200…400_LR OEZXU14/3 1SCA100361R1001 3 0.24

OS200…400_LR OEZXU14/4 1SCA101082R1001 4 0.32

OSS160GG3LS

Page 62: Switch fuses OS and OSM - ABB

62 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Terminal clamp sets for Al- and Cu-cables

Cable cross Units/ Weight/

Suitable section type unit

for switches [mm2] Type Order number [pcs] [kg]

Insulated versions

OS/OSM32G…63G 16…50 Al, 2.5…50 Cu OZXT1 1SCA022469R6310 3 0.05

OZXB-type Al/Cu connectors made of stainless steel

Cable cross Units/ Weight/

Suitable section Suitable type unit

for switches [mm2] shroud Type Order number [pcs] [kg]

OS/OSM100G…160G1) 10...70 OSS160G_ OZXB1L 1SCA022169R2030 3 0.15

OS/OSM100G…160G1) 95...185 OSS160G_ OZXB8 1SCA022744R1510 3 0.50

OS/OSM200 10...70 OSS200_L OZXB1L 1SCA022169R2030 3 0.15

OS/OSM200 25...120 OZXB2K OZXB2 1SCA022119R7610 3 0.34

OS/OSM2002) 25...120 OZXB2K OZXB2L 1SCA022158R7750 3 0.42

OS/OSM200 95...185 OSS200_L OZXB8 1SCA022744R1510 3 0.50

OS200 95...240 OSS200_L OZXB9 1SCA022750R3210 3 0.50

OSM250 10...70 OSS200_L OZXB1L 1SCA022169R2030 3 0.15

OS/OSM2502) 25...120 OZXB2K OZXB2L 1SCA022158R7750 3 0.42

OS/OSM2502) 95…185 OZXB3K OZXB3 1SCA022136R8100 3 1.30

OS/OSM2502) 2x(95…185) OZXB3K OZXB4 1SCA022137R4760 3 1.70

OS/OSM2502) 120...300 OZXB4K OZXB5 1SCA022137R2470 3 2.30

OS/OSM2502) 120...240 OZXB5K OZXB7L 1SCA022185R7130 3 1.20

OS/OSM2502) 95...185 OSS250_L OZXB8 1SCA022744R1510 3 0.50

OS2502) 95...240 OSS250_L OZXB9 1SCA022750R3210 3 0.50

OS200…400_LR_ 95…240 OSS400G4LSL OZXB17 1SCA022859R3230 3 0.531) Suitable for OS125G...160G_LR -types only with terminal angle OEZXU68 2) Suitable for OS250_BB -types, OS200B_LR, for OS250_LR types suitable only with terminal angle OEZXU14

OZXT1

OZXB8

OZXB2L

OZXB17

Page 63: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 63

Ordering informationAccessories

Terminal clamp sets for Al- and Cu-cables

Cable cross Units/ Weight/

Suitable section Suitable type unit

for switches [mm2] shroud Type Order number [pcs] [kg]

OZXB-type Al/Cu connectors made of stainless steel

OS/OSM315…4001) 25…120 OSS400_L OZXB2L 1SCA022158R7750 3 0.42

OS/OSM315…4001) 95…185 OZXB3K OZXB3 1SCA022136R8100 3 1.30

OS/OSM315…4001) 2x(95…185) OZXB3K OZXB4 1SCA022137R4760 3 1.70

OS315...4001) 120…300 OZXB4K OZXB5 1SCA022137R2470 3 2.30

OS315...4001) 2x(120…300) OZXB4K OZXB6 1SCA022137R4920 3 3.03

OS/OSM315...4001) 120…240 OZXB5K OZXB7 1SCA022185R0040 3 1.00

OS/OSM315…4001) 95…185 OSS400_L OZXB8 1SCA022744R1510 3 0.50

OS/OSM315…4001) 95…240 OSS400_L OZXB9 1SCA022750R3210 3 0.50

OS/OSM630...800 95…185 OSS800_L OZXB3 1SCA022136R8100 3 1.30

OS/OSM630...800 2x(95…185) OSS800_L OZXB4 1SCA022137R4760 3 1.70

OS/OSM630...800 120…300 OSS800_L OZXB5 1SCA022137R2470 3 2.30

OS/OSM630...800 2x(120…300) OSS800_L OZXB6 1SCA022137R4920 3 3.03

OS/OSM630...800 120…240 OSS800_L OZXB7L 1SCA022185R7130 3 1.20

OS/OSM630...800 95…185 OSS800_L OZXB8 1SCA022744R1510 3 0.50

OS/OSM630...800 95…240 OSS800_L OZXB9 1SCA022750R3210 3 0.501) Suitable for OS315...400_BB_-types, for OS315...400_LR_-types suitable only with terminal angle OEZXU14

OZXB2L

OZXB8

Page 64: Switch fuses OS and OSM - ABB

64 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Terminal clamp sets for Al- and Cu-cables

Cable cross Units/ Weight/

Suitable section Suitable type unit

for switches [mm2] shroud Type Order number [pcs] [kg]

OZXB-type Al/Cu connectors made of stainless steel

OS/OSM1250 95…185 OTS1600_L OZXB3 1SCA022136R8100 3 1.30

OS/OSM1250 2x(95…185) OTS1600_L OZXB4 1SCA022137R4760 3 1.70

OS/OSM1250 120…300 OTS1600_L OZXB5 1SCA022137R2470 3 2.30

OS/OSM1250 2x(120…300) OTS1600_L OZXB6 1SCA022137R4920 3 3.03

OS/OSM1250 120…240 OTS1600_L OZXB7L 1SCA022185R7130 3 1.20

OS/OSM1250 95…185 OTS1600_L OZXB8 1SCA022744R1510 3 0.50

OS/OSM1250 95…240 OTS1600_L OZXB9 1SCA022750R3210 3 0.50

OZXR type Al/Cu connectors made of stainless steel and copper2)

OS100G…160G1) 6…70 OSS160G_L OZXR70 1SCA115529R1001 3 0.15

OS100G…160G1) 25…95 OSS160G_L OZXR95 1SCA115530R1001 3 0.21

OS200 25…95 OSS200_L OZXR95 1SCA115530R1001 3 0.21

OS200 95…185 OSS200_L OZXR185 1SCA115531R1001 3 0.45

OS200 2x(95…185) - OZXR2X185 1SCA115534R1001 3 0.66

OS250 95…185 OSS250_L OZXR185 1SCA115531R1001 3 0.45

OS250 2x(95…185) - OZXR2X185 1SCA115534R1001 3 0.66

OS315…400 95…240 OSS400_L OZXR240 1SCA115532R1001 3 0.42

OS315…400 2x(95…185) - OZXR2X185 1SCA115534R1001 3 0.66

OS315…400 185…300 - OZXR300 1SCA115533R1001 3 0.87

OS630…800 2x(185…300) OSS800_L OZXR2X300 1SCA115535R1001 3 1.59

OZXP type Al/Cu connectors made of tin plated aluminium profile2)

OS100G…160G1) 6…95 OSS160G_L OZXP95 1SCA115539R1001 3 0.09

OS200 6…95 OSS200_L OZXP95 1SCA115539R1001 3 0.09

OS200 16…120 OSS200_L OZXP120 1SCA115540R1001 3 0.15

OS200 25…150 - OZXP150 1SCA115541R1001 3 0.18

OS200 35…240 - OZXP240 1SCA115542R1001 3 0.27

OS250 35…240 - OZXP240 1SCA115542R1001 3 0.27

OS315…400 35…240 - OZXP240 1SCA115542R1001 3 0.27

OS315…400 95…300 - OZXP300 1SCA115543R1001 3 0.42

OS315…400 2x(70…240) - OZXP2X240 1SCA115544R1001 3 1.38

OS630…800 2x(70…240) OSS800_L OZXP2X240 1SCA115544R1001 3 1.381) For _LR-types, suitable only with terminal angle OEZXU68 2) Suitable also for OS200...400_BB_, for OS200...400_LR_-types suitable only with terminal angle OEZXU14

OZXB8

OZXR95

OZXR185

OZXR240

OZXR300

Page 65: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 65

Ordering informationAccessories

Conversion kits for front operated combination switches

Suitable Switches Shaft Units/ Weight/

for needed distance type unit

switches [pcs] [mm] Type Order number [pcs] [kg]

6 and 8-pole switch mechanismParallel attachment for connecting 3- and 4-pole switches. The switches work simultaneously.

6-pole switches, OS Mini

OS Mini Two 3-pole OWP6DS1 1SCA105255R1001 1 0.69

8-pole switches, OS Mini

OS Mini Two 4-pole OWP6DS2 1SCA105256R1001 1 0.69

6 and 8-pole switches, OS32G...400

The attachment levers are provided with holes, enabling different shaft distances.

The combination switches can be mounted either horizontally or vertically.

OS32G...250 Two 3- or 4-pole 45+(0-13)x15 OESAZW2 1SCA022078R1600 1 0.37

OS315...400 Two 3- or 4-pole 60+(0-19)x20 OETLZW9 1SCA022061R3300 1 1.1

Change-over switch mechanismTwo switches connected with a mechanism operating into I-O-II positions.

OS Mini Two 3-pole - OWC6DSH1 1SCA105251R1001 1 1.0

OS Mini Two 4-pole - OWC6DSH2 1SCA105252R1001 1 1.0

OS32G...250 Two 3- or 4-pole 210+(0 - 18)x20 OTZW25 1SCA022778R6920 1 2.8

OS315...400 Two 3- or 4-pole 210+(0 - 11)x20 OETLZW11 1SCA022078R0030 1 3.0

OS315...400 Two 3- or 4-pole 210+(0 - 20)x20 OETLZW12 1SCA022078R0200 1 4.6

Bypass switch mechanismA combination of two switches in parallel with a third switch for change-over operation to bypass, for example, a breaker for maintenance. The bypass attachment can be used together with another combination attachment.

OS32G...250 Three 3- or 4-pole OTZW26 1SCA022778R7060 1 3.3

Between 1 and 2: 210+(0 - 9)x20

Between 1 and 3: 250+(0 - 9)x20

OS315...400 Three 3- or 4-pole OETLZW13 1SCA022078R0460 1 4.0

Between 1 and 2: 210+(0 - 18)x20

Between 1 and 3: 250+(0 - 18)x20

Mechanical interlock mechanismPrevents one switch from closing to ON -position, if the other is not in OFF - position.OTZW/OETLZW-types: When mounted upside down, prevents one switch from opening to OFF-position, if the other is not in the ON-position. (UPS-usage, make-before-break)

OS Mini Two 3-pole - OWM6DS1 1SCA105253R1001 1 0.30

OS Mini Two 4-pole - OWM6DS2 1SCA105254R1001 - 0.30

OS32G...250 Two 3- or 4-pole 190 OTZW10 1SCA022431R5280 1 0.40

OS315...800 Two 3- or 4-pole 250 OETLZW14 1SCA022077R3410 1 0.70

OS315...800 Two 3- or 4-pole 300 OETLZW3 1SCA022049R0380 1 0.80

OS315...1250 Two 3- or 4-pole 500 OETLZW15 1SCA022081R9340 1 1.24

OESAZW2

OETLZW3

OTZW25

OTZW26

Page 66: Switch fuses OS and OSM - ABB

66 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Shafts and handles for conversion kits

The standard

To be Included in the handle or shaft of

ordered conversion kit one of the combined

Conversion separately delivery switches can be used

kit type Shaft Handle Shaft Handle Shaft Handle

6 and 8-pole switches

OWP6DS1 x - - - - x

OWP6DS2 x - - - - x

OESAZW2 - - x (2 pcs) OHB145J12 - -

OETLZW9 - - - - x x

Change-over switches

OWC6DSH1 x (length min. 170mm) - - OHB65J6E011 - -

OWC6DSH2 x (length min. 170mm) - - OHB65J6E011 - -

OTZW25 - - x (2 pcs) OHB95J12E011 - -

OETLZW11 - - x (2 pcs) OHB145J12E011 - -

OETLZW12 - - x (2 pcs) YASDA21 - -

Bypass switches

OTZW26 - - x (3 pcs) OHB95J12E011 - -

OETLZW13 - - x (3 pcs) YASDA 6 - -

Mechanical interlock

OWM6DS1 x (2 pcs, length min. 170mm) x (2 pcs) - - - -

OWM6DS2 x (2 pcs, length min. 170mm) x (2 pcs) - - - -

OTZW10 - - - - x x

OETLZW14 - - - - x x

OETLZW3 - - - - x x

OETLZW15 - - - - x x

I ONI ON

II ON II ON

OOFF

OOFF

Change-over switches Bypass switches

II

III

I

I

I II

II

I

I

II

II

I II II I III

Change-over switches

Change-over and bypass switches

Mechanical interlock

I ONI ON

II ON II ON

OOFF

OOFF

Change-over switches Bypass switches

II

III

I

I

I II

II

I

I

II

II

I II II I III

I ONI ON

II ON II ON

OOFF

OOFF

Change-over switches Bypass switches

II

III

I

I

I II

II

I

I

II

II

I II II I III

Page 67: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 67

Ordering informationAccessories

Electronic fuse monitorIncludes the auxiliary contacts 1NO + 1NC. More information, see brochure OFM_OFS20GB.

Rated Weight/

voltage unit

[V] Type Order number [kg]

OS MiniMounting onto the left side of OS Mini (with a frame OSZ4) or on mounting plate.

120...240/AC OFM240 1SCA022579R1340 0.2

120...260/AC OFM260 1SCA022459R8560 0.14

380...600/AC OFM600 1SCA022579R1260 0.2

380...690/AC OFM690 1SCA022459R8480 0.14

OS/OSM32G…1250Mounting onto the left side of OS32G-1250 switch fuse (right side of OSM motorized switch fuses) or on DIN-rail or on mounting plate.

100…260/AC OFS260 1SCA022716R0180 0.16

380…690/AC OFS690 1SCA022715R9920 0.16

48...110/DC OFD110EA 1SCA121775R1001 0.155

110...500/DC OFD500EA 1SCA121776R1001 0.155

Mounting accessories for fuse monitor

Suitable Flat terminal Units/ Weight

for size type /unit

switches [mm] Type Order number [pcs] [kg]

Crimp terminals

OS_ 2.8 - 0.8 OFMZX2 1SCA022475R9910 6 0.01

Mounting frame for OS Mini

Mounting on the left side of the switch OSZ4 1SCA022530R0200 1 0.60

OFM260

OFS260

OFMZX2

OSZ4

OFD500EA

Page 68: Switch fuses OS and OSM - ABB

68 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

Blown fuse indicators (DPMM) Striker type fuse is needed. See the dimensions in IEC60269-2-1, Section 1A.

Suitable Weight/

for unit

switches Type Order number [kg]

OS MiniAuxiliary contact (1x C/O) included. See the ratings on page 63, type OA4

for 3-pole switches OSD25P3 1SCA022192R9060 0.10

for 4-pole switches, fused neutral OSD25P4 1SCA022196R9520 0.10

OS/OSM50GF_Auxiliary contacts (3 x C/O in 3-pole, 4 x C/O in 4-pole) included. Ratings: Ith: 5A, AC15: 0.15A/250VAC. NEMA 5A, 125-250 VAC, 1/10 HP

for 3-pole switches OSGD50P3 1SCA116401R1001 0.015

for 4-pole switches, fused neutral OSGD50P4 1SCA115689R1001 0.020

OS/OSM125GF_Auxiliary contacts (3 x C/O in 3-pole, 4 x C/O in 4-pole) included. Ratings: Ith: 5A, AC15: 0.15A/250VAC. NEMA 5A, 125-250 VAC, 1/10 HP

for 3-pole switches OSGD125P3 1SCA115690R1001 0.025

for 4-pole switches, fused neutral OSGD125P4 1SCA115692R1001 0.035

OS/OSM250D...800DAuxiliary contacts (3xNO + 3xNC in 3-pole and 4xNO + 4xNC in 4-pole) included. See the ratings on page 63, type OA1G_, OA3G_

for 3-pole switches OSZX3 1SCA101224R1001 0.15

for 4-pole switches, fused neutral OSZX4 1SCA101225R1001 0.20

OSD25P3

OSGD50P4

OSZX3

OSGD125P3

Page 69: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Ordering information 69

Ordering informationAccessories

Cam attachmentFor Castell, Lowe & Fletcher and Ronis interlock. Cam attachment for adapting the switches to the interlock system. The interlock is not included.

Suitable Weight

for /unit

switches Type Order number [kg]

OS16...250 OETLZW16 1SCA022095R2070 0.17

OS315...1250 OETLZW5 1SCA022052R3900 0.14

Mechanism interlock kits and Electrical interlocksOS32G…1250 switch fuses can be interlocked in the OFF position using padlocks and by using a mechanical interlock kit mounted on the mechanism. The diameter of the lock bail can be max 8 mm.Note: The shaft must go through the interlock into the switch mechanism.

Suitable Weight

for /unit

switches Type Order number [kg]

Interlocking in the OFF position

OS32G...160G OTZT1A 1SCA106522R1001 0.21

OS200 … 250_ OSZT1A 1SCA106532R1001 0.32

OS315 … 400_ OSZT2A 1SCA106534R1001 0.75

OS600 …800_ OSZT3A 1SCA106535R1001 1.20

OS1200 … 1250_ OSZT4A 1SCA106536R1001 2.00

Interlocking in the OFF & ON positions

OS32G...160G OTZT1L 1SCA106527R1001 0.21

OS200 … 250_ OSZT1L 1SCA106538R1001 0.32

OS315 … 400_ OSZT2L 1SCA106539R1001 0.75

OS600 …800_ OSZT3L 1SCA106540R1001 1.20

OS1200 … 1250_ OSZT4L 1SCA106541R1001 2.00

OSZT1A

OSZT2A

Page 70: Switch fuses OS and OSM - ABB

70 Ordering information | Switch fuses OS and OSM

Ordering informationAccessories

CoilsBy installing a coil inside the housing of the interlock kit the switch can be interlocked electrically in the OFF position or both in the OFF and ON positions. The electrical interlock works using the “closed circuit principle”, meaning that when the control voltage is not connected to the coil, the switches provided with A-type interlocks cannot be turned to the ON position and switches with L-type interlocks cannot be turned to the ON or OFF positions.

Suitable Weight

for Order /unit

switches Type number [kg]

AC coils

24 VAC, 60 Hz PDAL2/24AC60Hz 1SCA111350R1001 0.15

110 VAC, 50Hz PDAL2/110AC50Hz 1SCA106543R1001 0.15

110 VAC, 60Hz PDAL2/110AC60Hz 1SCA107100R1001 0.15

120 VAC, 60 Hz PDAL2/120AC60Hz 1SCA111353R1001 0.15

208 VAC, 60Hz PDAL2/208AC60Hz 1SCA107101R1001 0.15

230 VAC, 50Hz PDAL2/230AC50Hz 1SCA107102R1001 0.15

240 VAC, 60 Hz PDAL2/240AC60Hz 1SCA111356R1001 0.15

DC coils

24 VDC PDAL2/24DC 1SCA106542R1001 0.15

48 VDC PDAL2/48DC 1SCA107103R1001 0.15

60 VDC PDAL2/60DC 1SCA107104R1001 0.15

110 VDC PDAL2/110DC 1SCA107105R1001 0.15

125 VDC PDAL2/125DC 1SCA111338R1001 0.15

220 VDC PDAL2/220DC 1SCA112503R1001 0.15

Technical data for the coil

Operating voltage U=0.7...1.1 x Un

Operating ambient temperature -40ºC...+65ºC

Power consumption with AC 6.5 W

with DC 9 VA

Mounting accessories

DIN-rail mounting kitFor mounting a switch fuse into 35 mm DIN-rail

Suitable for switches Weight

/unit

Type Order number [kg]

OS32G…160G, 1 - 4 -pole OSGZD1 1SCA115688R1001 0.20

PDAL2-230AC50Hz

OSGZD1

Page 71: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 71

Dimension drawings, IEC and UL/CSAFront operated switch fuses

OS40 Mini

OS Mini

36

95

105135...210

30

EN 50022

3585

97

38

4,5

33

14,3 30,8 27,6

106

75...80

6

S00

579C

65

45

Ø66I

O Test

9

OA 3G01OA 1G10 max 3+3

OA4B1C max 1+1

OSZ 4

74

4,5

33

30,8 27,6

142

75...80I

O Test

9

OA 3G01OA 1G10 max 3+3

OA4B1C max 1+1

OSZ 4

35,6

OS16...35FD12_

OS20...32FB12_

OS25...32FF12_

OS30FA_12_

OS16...35FD22_

OS20...32FB22_

OS25...32FF22_

OS30FA_12_

OS25FF1210OS32FF1214OS30FA12JOS30FA12CCOS16FD1201OS35FD1202

UL 198CCSA C22.2 No.106NFC63210,-63211

BS88-6IEC 60269-2-1

BS88-2IEC 60269-2-1OS20FB12A1OS32FB12A1OS32FB12A2

IEC 60269-2-1IEC 60260-3-1

BS88-6IEC 60269-2-1OS32FB22F1

BS88-2IEC 60269-2-1OS20FB22A1OS32FB22A1OS32FB22A2

IEC 60269-2-1IEC 60269-3-1NFC63210,-63211UL 198C

OS20FB22A1F OS32FB22A1F OS25FF2210F OS32FF2214FOS16FD2201FOS35FD2202FOS30FAJ22FOS30FACC22F

OS20FB22A1N1OS32FB22A1N1OS32FB22A2N1OS32FB22F1N1OS25FF2210N1OS32FF2214N1OS16FD2201N1OS35FD2202N1

41 41

9314,3

14...85

* *

* *

* *

*

*

OS32FB12F1

M00

224/

OS

16-3

5F_

A

36

95

133135...210

30

EN 50022

3585

97

38

4,5

3314,3 30,8 27,6

106

75...80

6

65

45

Ø66 I

O Test

9

OA 3G01OA 1G10 max 3+3

OA4B1C max 1+1

OSZ 4

74

4,5

3330,8

142

75...80I

O Test

9

OA 3G01OA 1G10 max 3+3

OA4B1C max 1+1

OSZ 4

OS 40 FD12000 OS 40 FD22000_

OS40FD22000N1

41 41

121 14,3

14...133

27,6

DIN 000 DIN 000OS40FD12000

M00

223/

OS

40F_

A

Page 72: Switch fuses OS and OSM - ABB

72 Dimension drawings | Switch fuses OS and OSM

Dimension drawings, IECFront operated switch fuses

Mechanism at the end of the switch fuse

Mechanism between the poles

OS32...63G_P

T

OOFF

ONI

GF E

M53/16

DH C

A

80,31

291,14

70,28

138...205 (OXP 6x161)5,43...8,07

451,77

1124,41

14 min0,35

B

mmin

45/1,77

100/3,94

T

OOFF

ONI

A2

114

A1

T

OOFF

ONI

B2

B1

84

M00

288/

OS

32-6

3G_1

1-22

B

OS32-63GD

[mm] D11 D12 D13 D22

A 91 114,5 138 138

B 120,5 120,5 120,5 120,5

C - 23,5 23,5 23,5

D 60 60 60 60

E 30 30 30 30

F 44 44 44 67,5

G 74 74 74 97,5

A1 70 93,5 117 117

A2 35 35 35 58,5

B1 100 123,5 147 147

B2 50 50 50 73,5

OS32-63GB/F

[mm] B/F11 B/F12 B/F13 B/F22

A 91 114,5 138 138

B 108,5 108,5 108,5 108,5

C - 23,5 23,5 23,5

D 60 60 60 60

E 30 30 30 30

F 44 44 44 67,5

G 74 74 74 97,5

A1 70 93,5 117 117

A2 35 35 35 58,5

B1 100 123,5 147 147

B2 50 50 50 73,5

OS60GJ

[mm/in] J11 J12 J13 J22

A 112,5/4,43 148/5,82 182,5/7,19 182,5/7,19

B 118/4,65 118/4,65 118/4,65 118/4,65

C - 35/1,38 35/1,38 35/1,38

D 71,5/2,81 71,5/2,81 71,5/2,81 71,5/2,81

E 36/1,41 36/1,41 36/1,41 36/1,41

F 55,5/2,19 55,5/2,19 55,5/2,19 90,5/3,56

G 91,5/3,6 91,5/3,6 91,5/3,6 126,5/4,98

A1 81,5/3,21 116,5/4,59 151,5/5,96 151,5/5,96

A2 40,5/1,59 40,5/1,59 40,5/1,59 75,5/2,97

B1 111,5/4,39 146,5/5,77 181,5/7,15 181,5/7,15

B2 56/2,20 56/2,20 56/2,20 90,5/3,56

T

OOFF

ONI

GF E

M53/16

DH C

A

80,31

291,14

70,28

138...205 (OXP 6x161)5,43...8,07

451,77

1124,41

14 min0,35

B

mmin

45/1,77

100/3,94

T

OOFF

ONI

A2

114

A1

T

OOFF

ONI

B2

B1

84

M00

288/

OS

32-6

3G_1

1-22

B

OS32-63GD

[mm] D11 D12 D13 D22

A 91 114,5 138 138

B 120,5 120,5 120,5 120,5

C - 23,5 23,5 23,5

D 60 60 60 60

E 30 30 30 30

F 44 44 44 67,5

G 74 74 74 97,5

A1 70 93,5 117 117

A2 35 35 35 58,5

B1 100 123,5 147 147

B2 50 50 50 73,5

OS32-63GB/F

[mm] B/F11 B/F12 B/F13 B/F22

A 91 114,5 138 138

B 108,5 108,5 108,5 108,5

C - 23,5 23,5 23,5

D 60 60 60 60

E 30 30 30 30

F 44 44 44 67,5

G 74 74 74 97,5

A1 70 93,5 117 117

A2 35 35 35 58,5

B1 100 123,5 147 147

B2 50 50 50 73,5

OS60GJ

[mm/in] J11 J12 J13 J22

A 112,5/4,43 148/5,82 182,5/7,19 182,5/7,19

B 118/4,65 118/4,65 118/4,65 118/4,65

C - 35/1,38 35/1,38 35/1,38

D 71,5/2,81 71,5/2,81 71,5/2,81 71,5/2,81

E 36/1,41 36/1,41 36/1,41 36/1,41

F 55,5/2,19 55,5/2,19 55,5/2,19 90,5/3,56

G 91,5/3,6 91,5/3,6 91,5/3,6 126,5/4,98

A1 81,5/3,21 116,5/4,59 151,5/5,96 151,5/5,96

A2 40,5/1,59 40,5/1,59 40,5/1,59 75,5/2,97

B1 111,5/4,39 146,5/5,77 181,5/7,15 181,5/7,15

B2 56/2,20 56/2,20 56/2,20 90,5/3,56

M00

287/

OS

32-6

3G_0

1-04

B

OS32-63GD

[mm] D01 D02 D03 D04

A 64,5 88 111,5 135,5

B 120,5 120,5 120,5 120,5

C - 23,5 23,5 23,5

D 40 40 40 40

E 30 30 30 30

A1 45 68,5 92 111,5

B1 75 98,5 122 145,5

OS32-63GB/F

[mm] B/F01 B/F02 B/F03 B/F04

A 64,5 88 111,5 135,5

B 108,5 108,5 108,5 108,5

C - 23,5 23,5 23,5

D 40 40 40 40

E 30 30 30 30

A1 45 68,5 92 111,5

B1 75 98,5 122 145,5

OS60GJ

[mm/in] J01 J02 J03 J04

A 74,5/2,93 109,5/4,31 144,5/5,69 179,5/7,07

B 118/4,65 118/4,65 118/4,65 118/4,65

C - 35/1,38 35/1,38 35/1,38

D 45,5/1,79 45,5/1,79 45,5/1,79 45,5/1,79

E 36/1,41 36/1,41 36/1,41 36/1,41

A1 51/2,01 86/3,39 121/4,76 156/6,14

B1 81/3,19 116/4,57 151/5,94 186/7,32

T

OOFF

ON

D C

A

100/3,94

57/2,24

47,51,87

17,50,69

E

100/3,94

45/1,77

138...205 (OXP 6x161)5,43...8,07

451,77

112/4,41

14 min0,55

B

60,24

80,31

291,14

70,28

mmin

M53/16

T

OOFF

ON

A1

1144,49

100,39

T

OOFF

ON

843,31

B1

250,98

M00

287/

OS

32-6

3G_0

1-04

B

OS32-63GD

[mm] D01 D02 D03 D04

A 64,5 88 111,5 135,5

B 120,5 120,5 120,5 120,5

C - 23,5 23,5 23,5

D 40 40 40 40

E 30 30 30 30

A1 45 68,5 92 111,5

B1 75 98,5 122 145,5

OS32-63GB/F

[mm] B/F01 B/F02 B/F03 B/F04

A 64,5 88 111,5 135,5

B 108,5 108,5 108,5 108,5

C - 23,5 23,5 23,5

D 40 40 40 40

E 30 30 30 30

A1 45 68,5 92 111,5

B1 75 98,5 122 145,5

OS60GJ

[mm/in] J01 J02 J03 J04

A 74,5/2,93 109,5/4,31 144,5/5,69 179,5/7,07

B 118/4,65 118/4,65 118/4,65 118/4,65

C - 35/1,38 35/1,38 35/1,38

D 45,5/1,79 45,5/1,79 45,5/1,79 45,5/1,79

E 36/1,41 36/1,41 36/1,41 36/1,41

A1 51/2,01 86/3,39 121/4,76 156/6,14

B1 81/3,19 116/4,57 151/5,94 186/7,32

T

OOFF

ON

D C

A

100/3,94

57/2,24

47,51,87

17,50,69

E

100/3,94

45/1,77

138...205 (OXP 6x161)5,43...8,07

451,77

112/4,41

14 min0,55

B

60,24

80,31

291,14

70,28

mmin

M53/16

T

OOFF

ON

A1

1144,49

100,39

T

OOFF

ON

843,31

B1

250,98

Page 73: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 73

M00

289/

OS

100-

160G

_01-

04

C

OS100-160G_

[mm] D/F01 D/F02 D/F03 D/F04

A 76,5 111,5 146,5 181,5

B 130 130 130 130

C 100 100 100 100

A1 55 90 125 160

B1 70 105 140 175

C1 85 120 155 190

OS100-200G_

[mm] B01 B02 B03 B04

A 76,5 111,5 146,5 181,5

B 114,5 114,5 114,5 114,5

C 118 118 118 118

A1 55 90 125 160

B1 70 105 140 175

C1 85 120 155 190

T

OOFF

ON

10

114

A1

T

OOFF

ON

B1

110

17,5

T

OOFF

ON

C1

84

25

C

65

45

81

138...205 (OXP 6x161)

38 2,5

242,5

46

140

14 min

B

6

Ø9

10

20

Backconnectiontypes:

T

OOFF

ON

95,5

4317,5

53,3

33,4

20

8,5 7,25,5

114,5

M5

46 35

A

Dimension drawings, IECFront operated switch fuses

OS100...160G_PMechanism at the end of the switch fuse

Mechanism between the poles

M00

290/

OS

100-

160G

_11-

22

B

OS100-160GD/F

[mm] D/F11 D/F12 D/F13 D/F22

A 113 148 183 183

B 130 130 130 130

C 100 100 100 100

D 81 81 81 116

A1 90 125 160 160

A2 45 45 45 80

B1 105 140 175 175

B2 52,5 52,5 52,5 87,5

C1 120 155 190 190

C2 60 60 60 95

OS100-160GB

[mm] B11 B12 B13 B22

A 113 148 183 183

B 114,5 114,5 114,5 114,5

C 118 118 118 118

D 81 81 81 116

A1 90 125 160 160

A2 45 45 45 80

B1 105 140 175 175

B2 52,5 52,5 52,5 87,5

C1 120 155 190 190

C2 60 60 60 95

T

OOFF

ON

T

OOFF

ON

T

OOFF

ON

A2

114

A1

110

B2

B1

84

C1

C2

T

OOFF

ON

95,5

43

36

33,4

20

8,5

7,2

5,5

71,5 35

D

A

M5

114,5 Back connection types:

Ø9

1020

C

65

6

45

81

138...205 (OXP 6x161)

38 2,5

2024

140

46

2,5

14 min

B

M00

290/

OS

100-

160G

_11-

22

B

OS100-160GD/F

[mm] D/F11 D/F12 D/F13 D/F22

A 113 148 183 183

B 130 130 130 130

C 100 100 100 100

D 81 81 81 116

A1 90 125 160 160

A2 45 45 45 80

B1 105 140 175 175

B2 52,5 52,5 52,5 87,5

C1 120 155 190 190

C2 60 60 60 95

OS100-160GB

[mm] B11 B12 B13 B22

A 113 148 183 183

B 114,5 114,5 114,5 114,5

C 118 118 118 118

D 81 81 81 116

A1 90 125 160 160

A2 45 45 45 80

B1 105 140 175 175

B2 52,5 52,5 52,5 87,5

C1 120 155 190 190

C2 60 60 60 95

T

OOFF

ON

T

OOFF

ON

T

OOFF

ON

A2

114

A1

110

B2

B1

84

C1

C2

T

OOFF

ON

95,5

43

36

33,4

20

8,5

7,2

5,5

71,5 35

D

A

M5

114,5 Back connection types:

Ø9

1020

C

65

6

45

81

138...205 (OXP 6x161)

38 2,5

2024

140

46

2,5

14 min

B

M00

289/

OS

100-

160G

_01-

04

C

OS100-160G_

[mm] D/F01 D/F02 D/F03 D/F04

A 76,5 111,5 146,5 181,5

B 130 130 130 130

C 100 100 100 100

A1 55 90 125 160

B1 70 105 140 175

C1 85 120 155 190

OS100-200G_

[mm] B01 B02 B03 B04

A 76,5 111,5 146,5 181,5

B 114,5 114,5 114,5 114,5

C 118 118 118 118

A1 55 90 125 160

B1 70 105 140 175

C1 85 120 155 190

T

OOFF

ON

10

114

A1

T

OOFF

ON

B1

110

17,5

T

OOFF

ON

C1

84

25

C

65

45

81

138...205 (OXP 6x161)

38 2,5

242,5

46

140

14 min

B

6

Ø9

10

20

Backconnectiontypes:

T

OOFF

ON

95,5

4317,5

53,3

33,4

20

8,5 7,25,5

114,5

M5

46 35

A

Page 74: Switch fuses OS and OSM - ABB

74 Dimension drawings | Switch fuses OS and OSM

Dimension drawings, IECFront operated switch fuses

OS200_P and OS250_PMechanism at the end of the switch fuse

Mechanism between the poles

8,5

A1

144

18

B1

138,5

26,5

C1

108126

72

20

14 min

45

36

(OXP 6X210)

65

75

OS 250:116/46OS 200:110/46

OS 250: 53OS 200: 43

HF G

A

M

KL

I

J

40,5

D

C

B

E

20

33,5

10,5

8,48,6

189...254

M5

*) OS_N3

*)

*)

5,50,22

M00

008/

OS

200_

250_

01_0

4 H

OS200

[mm] D01 B01 D02 B02 D03 B03 D04 B04

A 89,5 89,5 133 133 176,5 176,5 220 220

B 149 130 149 130 149 130 149 130

C 198,5 198,5 198,5 198,5 198,5 198,5 198,5 198,5

D 36,5 36,5 36,5 36,5 36,5 36,5 36,5 36,5

E 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5

F 48,5 48,5 48,5 48,5 48,5 48,5 48,5 48,5

G - - 43,5 43,5 43,5 43,5 43,5 43,5

H 20 20 20 20 20 20 20 20

I 40 40 40 40 40 40 40 40

J 10 10 10 10 10 10 10 10

K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4

L 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6

M 164,5 164,5 164,5 164,5 164,5 164,5 164,5 164,5

A1 60,5 60,5 104 104 147,5 147,5 191 191

B1 79,5 79,5 123 123 166,5 166,5 210 210

C1 96,5 96,5 140 140 183,5 183,5 227 227

OS250

[mm] D01/B01 D02/B02 D03/B03 D04/B04

A 99,5 153,5 207,5 261,5

B 154 154 154 154

C 193 193 193 193

D 33,5 33,5 33,5 33,5

E 148,5 148,5 148,5 148,5

F 53,5 53,5 53,5 53,5

G - 54 54 54

H 25 25 25 25

I 45 45 45 45

J 11 11 11 11

K 11,5 11,5 11,5 11,5

L 4 4 4 4

M 162 162 162 162

A1 70,5 124,5 178,5 232,5

B1 89,5 143,5 197,5 251,5

C1 106,5 160,5 214,5 268,5

8,5

A1

144

18

B1

138,5

26,5

C1

108126

72

20

14 min

45

36

(OXP 6X210)

65

75

OS 250:116/46OS 200:110/46

OS 250: 53OS 200: 43

HF G

A

M

KL

I

J

40,5

D

C

B

E

20

33,5

10,5

8,48,6

189...254

M5

*) OS_N3

*)

*)

5,50,22

M00

008/

OS

200_

250_

01_0

4 H

OS200

[mm] D01 B01 D02 B02 D03 B03 D04 B04

A 89,5 89,5 133 133 176,5 176,5 220 220

B 149 130 149 130 149 130 149 130

C 198,5 198,5 198,5 198,5 198,5 198,5 198,5 198,5

D 36,5 36,5 36,5 36,5 36,5 36,5 36,5 36,5

E 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5

F 48,5 48,5 48,5 48,5 48,5 48,5 48,5 48,5

G - - 43,5 43,5 43,5 43,5 43,5 43,5

H 20 20 20 20 20 20 20 20

I 40 40 40 40 40 40 40 40

J 10 10 10 10 10 10 10 10

K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4

L 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6

M 164,5 164,5 164,5 164,5 164,5 164,5 164,5 164,5

A1 60,5 60,5 104 104 147,5 147,5 191 191

B1 79,5 79,5 123 123 166,5 166,5 210 210

C1 96,5 96,5 140 140 183,5 183,5 227 227

OS250

[mm] D01/B01 D02/B02 D03/B03 D04/B04

A 99,5 153,5 207,5 261,5

B 154 154 154 154

C 193 193 193 193

D 33,5 33,5 33,5 33,5

E 148,5 148,5 148,5 148,5

F 53,5 53,5 53,5 53,5

G - 54 54 54

H 25 25 25 25

I 45 45 45 45

J 11 11 11 11

K 11,5 11,5 11,5 11,5

L 4 4 4 4

M 162 162 162 162

A1 70,5 124,5 178,5 232,5

B1 89,5 143,5 197,5 251,5

C1 106,5 160,5 214,5 268,5

A2

144

A1

C2

108

C1

138,5

B2

B1

72

G I

J

144

LK

M

N FE

H

20

10,58,48,6

33,5

M5

*) OS_N3:

*)

*)

M00

014/

OS

200_

250_

11_2

2 K

OS200

[mm] D11 B11 D12 B12 D13 B13 D22 B22

A 149 130 149 130 141 130 149 130

B 199 199 199 199 199 199 199 199

C 36,5 36,5 36,3 36,5 36,5 36,5 36,5 36,5

D 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5

E 92 92 92 92 92 92 135,5 135,5

F 43,5 43,5 43,5 43,5 43,5 43,5 43,5 43,5

G 20 20 20 20 20 20 20 20

H 132 132 175,5 175,5 219 219 219 219

I 40 40 40 40 40 40 40 40

J 10 10 10 10 10 10 10 10

K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4

L 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6

M 165 165 165 165 165 165 165 165

N 80 80 80 80 80 80 80 80

A1 104 104 147,5 147,5 191 191 191 191

A2 52 52 52 52 52 52 95,5 95,5

B1 123 123 166,5 166,5 210 210 210 210

B2 61,5 61,5 61,5 61,5 61,5 61,5 105 105

C1 140 140 183,5 183,5 227 227 227 227

C2 70 70 70 70 70 70 113,5 113,5

OS250

[mm] D11 D12 D13 D22

A 154 154 154 154

B 193 193 193 193

C 33,5 33,5 33,5 33,5

D 148,5 148,5 148,5 148,5

E 112,5 112,5 112,5 161

F 54 54 54 54

G 25 25 25 25

H 152 206 260 260

I 45 45 45 45

J 11 11 11 11

K 11,5 11,5 11,5 11,5

L 4 4 4 4

M 162 162 162 162

N 90 90 90 90

A1 124 178 232 232

A2 62 62 62 116

B1 143 197 251 251

B2 71,5 71,5 71,5 125,5

C1 160 214 268 268

C2 80 80 80 134

A2

144

A1

C2

108

C1

138,5

B2

B1

72

G I

J

144

LK

M

N FE

H

20

10,58,48,6

33,5

M5

*) OS_N3:

*)

*)

M00

014/

OS

200_

250_

11_2

2 K

OS200

[mm] D11 B11 D12 B12 D13 B13 D22 B22

A 149 130 149 130 141 130 149 130

B 199 199 199 199 199 199 199 199

C 36,5 36,5 36,3 36,5 36,5 36,5 36,5 36,5

D 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5

E 92 92 92 92 92 92 135,5 135,5

F 43,5 43,5 43,5 43,5 43,5 43,5 43,5 43,5

G 20 20 20 20 20 20 20 20

H 132 132 175,5 175,5 219 219 219 219

I 40 40 40 40 40 40 40 40

J 10 10 10 10 10 10 10 10

K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4

L 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6

M 165 165 165 165 165 165 165 165

N 80 80 80 80 80 80 80 80

A1 104 104 147,5 147,5 191 191 191 191

A2 52 52 52 52 52 52 95,5 95,5

B1 123 123 166,5 166,5 210 210 210 210

B2 61,5 61,5 61,5 61,5 61,5 61,5 105 105

C1 140 140 183,5 183,5 227 227 227 227

C2 70 70 70 70 70 70 113,5 113,5

OS250

[mm] D11 D12 D13 D22

A 154 154 154 154

B 193 193 193 193

C 33,5 33,5 33,5 33,5

D 148,5 148,5 148,5 148,5

E 112,5 112,5 112,5 161

F 54 54 54 54

G 25 25 25 25

H 152 206 260 260

I 45 45 45 45

J 11 11 11 11

K 11,5 11,5 11,5 11,5

L 4 4 4 4

M 162 162 162 162

N 90 90 90 90

A1 124 178 232 232

A2 62 62 62 116

B1 143 197 251 251

B2 71,5 71,5 71,5 125,5

C1 160 214 268 268

C2 80 80 80 134

Page 75: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 75

Dimension drawings, IECFront operated switch fuses

OS315_P and OS400_PMechanism at the end of the switch fuse

Mechanism between the poles

A1

164

17

B1

159

26

C1

128

35

C00

0014

/O

S31

5_40

0_00

1_04

A

4512

95

C

230...325 (OXP 12 x 250)B

230

40

43,5 5

A

75,5 64 25

193

82

min 20

50,3/125,458,5

11,5

140

7,5 10,8

64

28

81

M53/16

OS315

[mm] B01 B02 B03 B04

A 127 191 255 319

B 176 176 176 176

C 194 194 194 194

OS400

[mm] B01 B02 B03 B04 D01 D02 D03 D04

A 127 191 255 319 127 191 255 319

B 176 176 176 176 193 193 193 193

C 194 194 194 194 166 166 166 166

OS315

[mm] B01 B02 B03 B04

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

OS400

[mm] B01/D01 B02/D02 B03/D03 B04/D04

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

A1

164

17

B1

159

26

C1

128

35

C00

0014

/O

S31

5_40

0_00

1_04

A

4512

95

C

230...325 (OXP 12 x 250)B

230

40

43,5 5

A

75,5 64 25

193

82

min 20

50,3/125,458,5

11,5

140

7,5 10,8

64

28

81

M53/16

OS315

[mm] B01 B02 B03 B04

A 127 191 255 319

B 176 176 176 176

C 194 194 194 194

OS400

[mm] B01 B02 B03 B04 D01 D02 D03 D04

A 127 191 255 319 127 191 255 319

B 176 176 176 176 193 193 193 193

C 194 194 194 194 166 166 166 166

OS315

[mm] B01 B02 B03 B04

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

OS400

[mm] B01/D01 B02/D02 B03/D03 B04/D04

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

A1

1646,46

A2

B1

1596,26

B2

C1

1285,04

C2

C00

0011

/OS

315-

400_

11_2

2

B

451,77

120,47

953,74

B

230...325 (OXP 12x250)9,06...12,80

A

2309,06

50,20

401,57

min 200,79

43,51,7155,8/130,9

2,20/5,15

50,20

*) OS_N3DC

642,52

1174,61

1937,60

25

0,9810,87,5

642,5258,5

2,30

0,4511,5

M53/16

0,30

*)

*)

0,43

OS315

[mm] B11 B12 B21 B22 B13

A1 163 227 227 291 291

A2 81,5 81,5 145,5 145,5 81,5

B1 181 245 245 309 309

B2 90,5 90,5 154,5 154,5 90,5

C1 199 263 263 327 327

C2 99,5 99,5 163,5 163,5 99,5

OS400

[mm] B11/D11 B12/D12 B21/D21 B22/D22 B13/D13

A1 163 227 227 291 291

A2 81,5 81,5 145,5 145,5 81,5

B1 181 245 245 309 309

B2 90,5 90,5 154,5 154,5 90,5

C1 199 263 263 327 327

C2 99,5 99,5 163,5 163,5 99,5

OS315-400

[mm] B11 B12 B13 B21 B22

A 176 176 176 176 176

B 194 194 194 194 194

C 140 140 140 204 204

D 190 254 318 254 318

OS400

[mm] D11 D12 D13 D21 D22

A 193 193 193 193 193

B 166 166 166 166 166

C 140 140 140 204 204

D 190 254 318 254 318

A1

1646,46

A2

B1

1596,26

B2

C1

1285,04

C2

C00

0011

/OS

315-

400_

11_2

2

B

451,77

120,47

953,74

B

230...325 (OXP 12x250)9,06...12,80

A

2309,06

50,20

401,57

min 200,79

43,51,7155,8/130,9

2,20/5,15

50,20

*) OS_N3DC

642,52

1174,61

1937,60

25

0,9810,87,5

642,5258,5

2,30

0,4511,5

M53/16

0,30

*)

*)

0,43

OS315

[mm] B11 B12 B21 B22 B13

A1 163 227 227 291 291

A2 81,5 81,5 145,5 145,5 81,5

B1 181 245 245 309 309

B2 90,5 90,5 154,5 154,5 90,5

C1 199 263 263 327 327

C2 99,5 99,5 163,5 163,5 99,5

OS400

[mm] B11/D11 B12/D12 B21/D21 B22/D22 B13/D13

A1 163 227 227 291 291

A2 81,5 81,5 145,5 145,5 81,5

B1 181 245 245 309 309

B2 90,5 90,5 154,5 154,5 90,5

C1 199 263 263 327 327

C2 99,5 99,5 163,5 163,5 99,5

OS315-400

[mm] B11 B12 B13 B21 B22

A 176 176 176 176 176

B 194 194 194 194 194

C 140 140 140 204 204

D 190 254 318 254 318

OS400

[mm] D11 D12 D13 D21 D22

A 193 193 193 193 193

B 166 166 166 166 166

C 140 140 140 204 204

D 190 254 318 254 318

Page 76: Switch fuses OS and OSM - ABB

76 Dimension drawings | Switch fuses OS and OSM

Dimension drawings, IECFront operated switch fuses

OS 630_P and OS 800_PMechanism at the end of the switch fuse

Mechanism between the poles

306

233

min 20

13

50

6

48.4

12

45 36

145

(OXP 12X280)

142/67

5

256...379

A102.5

88 53

39

230 254 266

39OS_N3

M8

ON

OFF

T

77.5 77.5

613.5 20

B

232 ON

OFF

T

C

223.3ON

OFF

T

D

176ON

OFF

T

OS630-800

[mm] D/B11 D/B12 D/B13 D/B22

A 253 341 429 429

B 205 293 381 381

C 235 323 411 411

D 261 349 437 437

KE

0004

2 /

M00

100/

OS

600-

800_

11-2

2 A

B

232

C

223.3

D

176306

233

min 20

13

50

6

48.4

12

45 36

145

(OXP 12X280)

142/67

5

256...379

36.5

39

OS_N3

77.5

A95

88

6

13.5

20

39

230 254 266

M8

ON

OFF

T

ON

OFF

T

ON

OFF

T

ON

OFF

T

OS630-800

[mm] D/B01 D/B02 D/B03 D/B04

A 167 255 343 431

B 120 208 296 384

C 150 238 326 414

D 176 264 352 440

M00

097/

OS

600-

800_

01-0

4 A

/ K

E00

041

B

232

C

223.3

D

176306

233

min 20

13

50

6

48.4

12

45 36

145

(OXP 12X280)

142/67

5

256...379

36.5

39

OS_N3

77.5

A95

88

6

13.5

20

39

230 254 266

M8

ON

OFF

T

ON

OFF

T

ON

OFF

T

ON

OFF

T

OS630-800

[mm] D/B01 D/B02 D/B03 D/B04

A 167 255 343 431

B 120 208 296 384

C 150 238 326 414

D 176 264 352 440

M00

097/

OS

600-

800_

01-0

4 A

/ K

E00

041

306

233

min 20

13

50

6

48.4

12

45 36

145

(OXP 12X280)

142/67

5

256...379

A102.5

88 53

39

230 254 266

39OS_N3

M8

ON

OFF

T

77.5 77.5

613.5 20

B

232 ON

OFF

T

C

223.3ON

OFF

T

D

176ON

OFF

T

OS630-800

[mm] D/B11 D/B12 D/B13 D/B22

A 253 341 429 429

B 205 293 381 381

C 235 323 411 411

D 261 349 437 437

KE

0004

2 /

M00

100/

OS

600-

800_

11-2

2 A

Page 77: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 77

OS1200/1250

[mm] D/B11 D/B12 D/B13 D/B22

A 322 432 542 542

A1 276 386 496 496

B1 306 416 526 526

C1 322 442 552 552

M00

208/

OS

1200

-125

0_11

-22

C

26610,47

1385,44

A1

2108,27

1666,54

C1

257,510,14

1536,03

B1

OS

1250

D/B

_

13,50,53

35614,02

22,50,89

110,43

*) N3- types

39,51,56

98,53,88

1104,33

1977,76

A

28711,30

501,9722,5

0,89

501,9713,5

0,54200,79 6

0,24

110,43

34613,62

mmin

37,51,48

*)

*)

13,50,53

M85/16

min 40 0,79

120,47

451,77

120,47

933,66 58

2,28

371...48014,61...18,91 (OXP 12 X 395)

164,56,48

1756,89

1104,33

60,24

1325,20 14

0,5529411,57

27410,79

803,15

702,76

542,13

Dimension drawings, IECFront operated switch fuses

OS1200...1250_PMechanism at the end of the switch fuse

Mechanism between the poles

OS1200/1250

[mm] D/B01 D/B02 D/B03 D/B04

A 209 319 429 539

A1 166 276 386 496

B1 196 306 416 526

C1 222 332 442 552

A1

281,10

26610,47

431,69

257,510,14

B1

562,20

2108,27

C1

*) N3- types

OS

1250

D/B

_

13,50,53

35614,02

22,50,89

110,43

421,65

mmin

28711,30

34613,62

2409,45

98,53,88

1104,33

501,97

126,54,98

A

*)

*)

532,01

110,43

22,50,89

501,97

13,50,53

M85/16

451,77120,47

60,24

582,28

120,47

min 40 0,79

140,55

1325,2029411,57

366...47514,41...18,70(OXP 12 X 395)

933,66

60,24

1084,25

164,56,48

1104,33

1756,89

27410,79

803,15

702,76

542,13

M00

207/

OS

1200

-125

0_01

-04

C

OS1200/1250

[mm] D/B01 D/B02 D/B03 D/B04

A 209 319 429 539

A1 166 276 386 496

B1 196 306 416 526

C1 222 332 442 552

A1

281,10

26610,47

431,69

257,510,14

B1

562,20

2108,27

C1

*) N3- types

OS

1250

D/B

_

13,50,53

35614,02

22,50,89

110,43

421,65

mmin

28711,30

34613,62

2409,45

98,53,88

1104,33

501,97

126,54,98

A

*)

*)

532,01

110,43

22,50,89

501,97

13,50,53

M85/16

451,77120,47

60,24

582,28

120,47

min 40 0,79

140,55

1325,2029411,57

366...47514,41...18,70(OXP 12 X 395)

933,66

60,24

1084,25

164,56,48

1104,33

1756,89

27410,79

803,15

702,76

542,13

M00

207/

OS

1200

-125

0_01

-04

C

OS1200/1250

[mm] D/B11 D/B12 D/B13 D/B22

A 322 432 542 542

A1 276 386 496 496

B1 306 416 526 526

C1 322 442 552 552

M00

208/

OS

1200

-125

0_11

-22

C

26610,47

1385,44

A1

2108,27

1666,54

C1

257,510,14

1536,03

B1

OS

1250

D/B

_

13,50,53

35614,02

22,50,89

110,43

*) N3- types

39,51,56

98,53,88

1104,33

1977,76

A

28711,30

501,9722,5

0,89

501,9713,5

0,54200,79 6

0,24

110,43

34613,62

mmin

37,51,48

*)

*)

13,50,53

M85/16

min 40 0,79

120,47

451,77

120,47

933,66 58

2,28

371...48014,61...18,91 (OXP 12 X 395)

164,56,48

1756,89

1104,33

60,24

1325,20 14

0,5529411,57

27410,79

803,15

702,76

542,13

Page 78: Switch fuses OS and OSM - ABB

78 Dimension drawings | Switch fuses OS and OSMM00

292/

OS

100G

J11-

22

B

OS100GJ

[mm/in] J11 J12 J13 J22

A 113/4,45 148/5,83 183/7,20 183/7,20

B 81/3,19 81/3,19 81/3,19 116/4,57

A1 90/3,54 125/4,92 160/6,30 160/6,30

A2 45/1,77 45/1,77 45/1,77 80/3,15

B1 105/4,13 140/5,51 175/6,89 175/6,89

B2 52,5/2,07 52,5/2,07 52,5/2,07 160/3,44

C1 120/4,72 155/6,10 190/7,48 190/7,48

C2 60/2,36 60/2,36 60/2,36 95/3,74

T

OOFF

ON

M5

95,53,76

464,81

361,42

33,41,31200,798,5

0,33

71,52,81B

A351,38

60,24

2208,66

1726,77

602,36

361,42

138...205 (OXP 6x161)5,35...8,07

81/3,19

69/2,72

2,50,10

381,50

138,55,45

125,54,94

652,56

min 14 0,55

104,5/4,11

mmin

110,43

T

OOFF

ON

T

OOFF

ON

T

OOFF

ON

A2

1144,49

A1

1104,33

B2

B1 C1

843,31

C2

OS60GJ

[mm/in] J11 J12 J13 J22

A 112,5/4,43 148/5,82 182,5/7,19 182,5/7,19

B 118/4,65 118/4,65 118/4,65 118/4,65

C - 35/1,38 35/1,38 35/1,38

D 71,5/2,81 71,5/2,81 71,5/2,81 71,5/2,81

E 36/1,41 36/1,41 36/1,41 36/1,41

F 55,5/2,19 55,5/2,19 55,5/2,19 90,5/3,56

G 91,5/3,6 91,5/3,6 91,5/3,6 126,5/4,98

A1 81,5/3,21 116,5/4,59 151,5/5,96 151,5/5,96

A2 40,5/1,59 40,5/1,59 40,5/1,59 75,5/2,97

B1 111,5/4,39 146,5/5,77 181,5/7,15 181,5/7,15

B2 56/2,20 56/2,20 56/2,20 90,5/3,56

M00

291/

OS

100G

J01-

04

B

OS100GJ

[mm/in] J01 J02 J03 J04

A 76,5/3,01 111,5/4,39 146,5/5,77 181,5/7,15

A1 55/2,17 90/3,54 125/4,92 160/6,30

B1 70/2,76 105/4,13 140/5,51 175/6,89

C1 85/3,35 120/4,72 155/6,10 190/7,48

T

OOFF

ON

95,53,76

461,81

17,50,69

53,3/2,10

110,43

461,81

351,38

A

M5

138...205 (OXP 6x161)5,35...8,07

81/3,19

69/2,7260/2,36

361,42

2,50,10

381,50

2208,66

1726,77

min 14 0,55

104,5/4,11

652,56

125,54,94

138,55,45

mmin 45

1,77

60,24

33,41,31

200,798,5

0,33

T

OOFF

ON

T

OOFF

ON

T

OOFF

ON

C1250,98

843,31

B117,50,69

1104,33

1144,49

A1100,39

OS60GJ

[mm/in] J01 J02 J03 J04

A 74,5/2,93 109,5/4,31 144,5/5,69 179,5/7,07

B 118/4,65 118/4,65 118/4,65 118/4,65

C - 35/1,38 35/1,38 35/1,38

D 45,5/1,79 45,5/1,79 45,5/1,79 45,5/1,79

E 36/1,41 36/1,41 36/1,41 36/1,41

A1 51/2,01 86/3,39 121/4,76 156/6,14

B1 81/3,19 116/4,57 151/5,94 186/7,32

Dimension drawings, UL/CSAFront operated switch fuses

OS60...100GJ_Mechanism at the end of the switch fuse

Mechanism between the poles

M00

291/

OS

100G

J01-

04

B

OS100GJ

[mm/in] J01 J02 J03 J04

A 76,5/3,01 111,5/4,39 146,5/5,77 181,5/7,15

A1 55/2,17 90/3,54 125/4,92 160/6,30

B1 70/2,76 105/4,13 140/5,51 175/6,89

C1 85/3,35 120/4,72 155/6,10 190/7,48

T

OOFF

ON

95,53,76

461,81

17,50,69

53,3/2,10

110,43

461,81

351,38

A

M5

138...205 (OXP 6x161)5,35...8,07

81/3,19

69/2,7260/2,36

361,42

2,50,10

381,50

2208,66

1726,77

min 14 0,55

104,5/4,11

652,56

125,54,94

138,55,45

mmin 45

1,77

60,24

33,41,31

200,798,5

0,33

T

OOFF

ON

T

OOFF

ON

T

OOFF

ON

C1250,98

843,31

B117,50,69

1104,33

1144,49

A1100,39

OS60GJ

[mm/in] J01 J02 J03 J04

A 74,5/2,93 109,5/4,31 144,5/5,69 179,5/7,07

B 118/4,65 118/4,65 118/4,65 118/4,65

C - 35/1,38 35/1,38 35/1,38

D 45,5/1,79 45,5/1,79 45,5/1,79 45,5/1,79

E 36/1,41 36/1,41 36/1,41 36/1,41

A1 51/2,01 86/3,39 121/4,76 156/6,14

B1 81/3,19 116/4,57 151/5,94 186/7,32

M00

292/

OS

100G

J11-

22

B

OS100GJ

[mm/in] J11 J12 J13 J22

A 113/4,45 148/5,83 183/7,20 183/7,20

B 81/3,19 81/3,19 81/3,19 116/4,57

A1 90/3,54 125/4,92 160/6,30 160/6,30

A2 45/1,77 45/1,77 45/1,77 80/3,15

B1 105/4,13 140/5,51 175/6,89 175/6,89

B2 52,5/2,07 52,5/2,07 52,5/2,07 160/3,44

C1 120/4,72 155/6,10 190/7,48 190/7,48

C2 60/2,36 60/2,36 60/2,36 95/3,74

T

OOFF

ON

M5

95,53,76

464,81

361,42

33,41,31200,798,5

0,33

71,52,81B

A351,38

60,24

2208,66

1726,77

602,36

361,42

138...205 (OXP 6x161)5,35...8,07

81/3,19

69/2,72

2,50,10

381,50

138,55,45

125,54,94

652,56

min 14 0,55

104,5/4,11

mmin

110,43

T

OOFF

ON

T

OOFF

ON

T

OOFF

ON

A2

1144,49

A1

1104,33

B2

B1 C1

843,31

C2

OS60GJ

[mm/in] J11 J12 J13 J22

A 112,5/4,43 148/5,82 182,5/7,19 182,5/7,19

B 118/4,65 118/4,65 118/4,65 118/4,65

C - 35/1,38 35/1,38 35/1,38

D 71,5/2,81 71,5/2,81 71,5/2,81 71,5/2,81

E 36/1,41 36/1,41 36/1,41 36/1,41

F 55,5/2,19 55,5/2,19 55,5/2,19 90,5/3,56

G 91,5/3,6 91,5/3,6 91,5/3,6 126,5/4,98

A1 81,5/3,21 116,5/4,59 151,5/5,96 151,5/5,96

A2 40,5/1,59 40,5/1,59 40,5/1,59 75,5/2,97

B1 111,5/4,39 146,5/5,77 181,5/7,15 181,5/7,15

B2 56/2,20 56/2,20 56/2,20 90,5/3,56

Page 79: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 79

1445,67

A1

8,50,34

138,55,45

B1

180,71

1084,25

C1

26,51,04

8,68,4

20 40

10

72

126

48,5 461,81

A

20

164,5

0,79 1,57

0,40

0,340,33

6,48

2,83

4,96

1,91 0,79

200,79

10,50,43

8,4/0,33

8,6/0,34

33,5/1,32

M53/16

*) OS_N3:

*)

*)

132

189...254

14

198,5

40,5

36,5

45

159

3

6

(OXP 6X210)

652188,59

7,82

1,44

1,59 0,12

0,24 1,77

6,26

2,56

0,55min

752,95

5,20

7,44...10

110/464,33/1,81

5,50,22

M00

001/

OS

200J

01_0

4 H OS200

[mm/in] J01 J02 J03 J04

A 89,5 / 3,52 135,5/5,34 181,5/7,15 227,5/8,96

A1 60,5 / 2,38 106,5/4,19 152,5/6,00 198,5/7,82

B1 79,5 / 3,13 125,5/4,94 171,5/6,75 217,5/8,56

C1 96,5 / 3,80 142,5 / 5,61 188,5/7,42 234,5/9,23

Dimension drawings, UL/CSAFront operated switch fuses

OS200JMechanism at the end of the switch fuse

1445,67

A1

8,50,34

138,55,45

B1

180,71

1084,25

C1

26,51,04

8,68,4

20 40

10

72

126

48,5 461,81

A

20

164,5

0,79 1,57

0,40

0,340,33

6,48

2,83

4,96

1,91 0,79

200,79

10,50,43

8,4/0,33

8,6/0,34

33,5/1,32

M53/16

*) OS_N3:

*)

*)

132

189...254

14

198,5

40,5

36,5

45

159

3

6

(OXP 6X210)

652188,59

7,82

1,44

1,59 0,12

0,24 1,77

6,26

2,56

0,55min

752,95

5,20

7,44...10

110/464,33/1,81

5,50,22

M00

001/

OS

200J

01_0

4 H OS200

[mm/in] J01 J02 J03 J04

A 89,5 / 3,52 135,5/5,34 181,5/7,15 227,5/8,96

A1 60,5 / 2,38 106,5/4,19 152,5/6,00 198,5/7,82

B1 79,5 / 3,13 125,5/4,94 171,5/6,75 217,5/8,56

C1 96,5 / 3,80 142,5 / 5,61 188,5/7,42 234,5/9,23

A1

1646,46

170,67

B1

1596,26

261,02

C1

1285,04

351,38

*) OS_N3A

75,52,97

642,52

250,98

1937,60

823,23

58,52,30

11,50,45

1405,51

7,50,30

10,80,43

281,10

M53/16

*)

*)

45

813,19

1,7712

0,47

953,74

C

230...325 (OXP 12x250)9,06...12,80

B

2309,06

401,56

43,5

1,715

0,20

min 200,79

55,8/130,9

50,20

2,20/5,15

C00

0012

/O

S31

5_40

0_01

_04

B

OS400

[mm/in] J01 J02 J03 J04

A 127/5,00 191/7,52 255/10,04 319/12,56

B 176/6,93 176/6,93 176/6,93 176/6,93

C 194/7,64 194/7,64 194/7,64 194/7,64

OS400JMechanism at the end of the switch fuse

A1

1646,46

170,67

B1

1596,26

261,02

C1

1285,04

351,38

*) OS_N3A

75,52,97

642,52

250,98

1937,60

823,23

58,52,30

11,50,45

1405,51

7,50,30

10,80,43

281,10

M53/16

*)

*)

45

813,19

1,7712

0,47

953,74

C

230...325 (OXP 12x250)9,06...12,80

B

2309,06

401,56

43,5

1,715

0,20

min 200,79

55,8/130,9

50,20

2,20/5,15

C00

0012

/O

S31

5_40

0_01

_04

B

OS400

[mm/in] J01 J02 J03 J04

A 127/5,00 191/7,52 255/10,04 319/12,56

B 176/6,93 176/6,93 176/6,93 176/6,93

C 194/7,64 194/7,64 194/7,64 194/7,64

Page 80: Switch fuses OS and OSM - ABB

80 Dimension drawings | Switch fuses OS and OSM

Dimension drawings, UL/CSAFront operated switch fuses

OS600J and OS800LMechanism at the end of the switch fuse

B

232

C

223,3

D

1766,938,809,13

306

233

min 20

13

50

6

48,4

12

45 36

145

(OXP 12X280)

12,05

9,170,51

1,77 1,42

5,71

0,47

1,971,91

0,24

0,79

142/675,60/2,64

50,20

256...37910,08...14,92

36,5

39

OS_N3

77,5

A95

88

613,5

20

39

230

254

266

M8

1,54

1,44

0,53

5/160,79

0,24 1,54

3,74

3,05 3,46

10,47

9,06

10

M00

097

/ O

S 6

00-8

00_0

1-04

B

OS600-800

[mm/in] J/L01 J/L02 J/L03 J/L04

A 167/6,57 255/10,04 343/13,50 431/16,97

B 120/4,72 208/8,19 296/11,65 384/15,12

C 150/5,91 238/9,37 326/12,83 414/16,30

D 176/6,93 264/10,39 352/13,86 440/17,32

B

232

C

223,3

D

1766,938,809,13

306

233

min 20

13

50

6

48,4

12

45 36

145

(OXP 12X280)

12,05

9,170,51

1,77 1,42

5,71

0,47

1,971,91

0,24

0,79

142/675,60/2,64

50,20

256...37910,08...14,92

36,5

39

OS_N3

77,5

A95

88

613,5

20

39

230

254

266

M8

1,54

1,44

0,53

5/160,79

0,24 1,54

3,74

3,05 3,46

10,47

9,06

10

M00

097

/ O

S 6

00-8

00_0

1-04

B

OS600-800

[mm/in] J/L01 J/L02 J/L03 J/L04

A 167/6,57 255/10,04 343/13,50 431/16,97

B 120/4,72 208/8,19 296/11,65 384/15,12

C 150/5,91 238/9,37 326/12,83 414/16,30

D 176/6,93 264/10,39 352/13,86 440/17,32

OS1200/1250

[mm/in] L01 L02 L03 L04

A 209/8,23 319/12,56 429/16,89 539/21,22

A1 166/6,54 276/10,87 386/15,20 496/19,53

B1 196/7,72 306/12,05 416/16,38 526/20,71

C1 222/8,74 332/13,07 442/17,40 552/21,73

A1

281,10

26610,47

431,69

257,510,14

B1

562,20

2108,27

C1

*) N3- types

42616,77

OS

1200

L_

200,79

110,43

60,24

37,51,48

13,50,53

421,65

28711,30

34613,62

2409,45

98,53,88

1104,33

501,97

126,54,98

A

*)

*)

532,01

110,43

22,50,89

501,97

13,50,53

M85/16

451,77120,47

60,24

582,28

120,47

min 40 0,79

140,55

1325,2029411,57

366...47514,41...18,70(OXP 12 X 395)

933,66

60,24

1084,25

164,56,48

1104,33

1756,89

27410,79

803,15

702,76

542,13

M00

207/

OS

1200

-125

0_01

-04

C

OS1200L

OS1200/1250

[mm/in] L01 L02 L03 L04

A 209/8,23 319/12,56 429/16,89 539/21,22

A1 166/6,54 276/10,87 386/15,20 496/19,53

B1 196/7,72 306/12,05 416/16,38 526/20,71

C1 222/8,74 332/13,07 442/17,40 552/21,73

A1

281,10

26610,47

431,69

257,510,14

B1

562,20

2108,27

C1

*) N3- types

42616,77

OS

1200

L_

200,79

110,43

60,24

37,51,48

13,50,53

421,65

28711,30

34613,62

2409,45

98,53,88

1104,33

501,97

126,54,98

A

*)

*)

532,01

110,43

22,50,89

501,97

13,50,53

M85/16

451,77120,47

60,24

582,28

120,47

min 40 0,79

140,55

1325,2029411,57

366...47514,41...18,70(OXP 12 X 395)

933,66

60,24

1084,25

164,56,48

1104,33

1756,89

27410,79

803,15

702,76

542,13

M00

207/

OS

1200

-125

0_01

-04

C

Page 81: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 81

B

65

81

38 2,5

140

37

165

T

OOFF

ON

95,5

4317,5

53,3

33,4

20

8,5 7,25,5

114,5

M5

46 35

A

T

OOFF

ON

T

OOFF

ON

T

OOFF

ON

10

114

A1 B1

110

17,5

C1

84

25

M00

390/

OS

100-

160G

_01-

04K

A

OS100-160G_K

[mm] D/F01 D/F02 D/F03 D/F04

A 76,5 111,5 146,5 181,5

B 100 100 100 100

A1 55 90 125 160

B1 70 105 140 175

C1 85 120 155 190

OS100-160G_K

[mm] B01 B02 B03 B04

A 76,5 111,5 146,5 181,5

B 118 118 118 118

A1 55 90 125 160

B1 70 105 140 175

C1 85 120 155 190

100

112

65

37

165

A1

114

10

84

B1

25

T

OOFF

ON

T

OOFF

ON

T

OOFF

ON

C B

A

100

57

47,5

17,5 E

M5

M00

389/

OS

32-6

3G_0

1-04

K

A

OS32-63G_K

[mm] D01 D02 D03 D04

A 64,5 88 111,5 135,5

B 40 40 40 40

C - 23,5 23,5 23,5

E 30 30 30 30

A1 45 68,5 92 111,5

B1 75 98,5 122 145,5

OS32-63G_K

[mm] B/F01 B/F02 B/F03 B/F04

A 64,5 88 111,5 135,5

B 40 40 40 40

C - 23,5 23,5 23,5

E 30 30 30 30

A1 45 68,5 92 111,5

B1 75 98,5 122 145,5

Dimension drawings, IECFront operated switch fuses with direct mount handles

OS32G_K...OS63G_K

OS100G_K...OS160G_K

100

112

65

37

165

A1

114

10

84

B1

25

T

OOFF

ON

T

OOFF

ON

T

OOFF

ON

C B

A

100

57

47,5

17,5 E

M5

M00

389/

OS

32-6

3G_0

1-04

K

A

OS32-63G_K

[mm] D01 D02 D03 D04

A 64,5 88 111,5 135,5

B 40 40 40 40

C - 23,5 23,5 23,5

E 30 30 30 30

A1 45 68,5 92 111,5

B1 75 98,5 122 145,5

OS32-63G_K

[mm] B/F01 B/F02 B/F03 B/F04

A 64,5 88 111,5 135,5

B 40 40 40 40

C - 23,5 23,5 23,5

E 30 30 30 30

A1 45 68,5 92 111,5

B1 75 98,5 122 145,5

B

65

81

38 2,5

140

37

165

T

OOFF

ON

95,5

4317,5

53,3

33,4

20

8,5 7,25,5

114,5

M5

46 35

A

T

OOFF

ON

T

OOFF

ON

T

OOFF

ON

10

114

A1 B1

110

17,5

C1

84

25

M00

390/

OS

100-

160G

_01-

04K

A

OS100-160G_K

[mm] D/F01 D/F02 D/F03 D/F04

A 76,5 111,5 146,5 181,5

B 100 100 100 100

A1 55 90 125 160

B1 70 105 140 175

C1 85 120 155 190

OS100-160G_K

[mm] B01 B02 B03 B04

A 76,5 111,5 146,5 181,5

B 118 118 118 118

A1 55 90 125 160

B1 70 105 140 175

C1 85 120 155 190

Page 82: Switch fuses OS and OSM - ABB

82 Dimension drawings | Switch fuses OS and OSM

M00

081/

OS

315

-400

_01_

04K

B

OS315,OS400

[mm] B01K B02K B03K B04K

A 127 191 255 319

B 176 176 176 176

C 194 194 194 194

D 219 219 219 219

OS400

[mm] D01K D02K D03K D04K

A 127 191 255 319

B 193 193 193 193

C 166 166 166 166

D 236 236 236 236

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

M00

081/

OS

315

-400

_01_

04K

B

OS315,OS400

[mm] B01K B02K B03K B04K

A 127 191 255 319

B 176 176 176 176

C 194 194 194 194

D 219 219 219 219

OS400

[mm] D01K D02K D03K D04K

A 127 191 255 319

B 193 193 193 193

C 166 166 166 166

D 236 236 236 236

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

126

72

20

IG HJ

O

MN

K

L

A2

A1

8,5

B1

18

B2

C2

C1

26,5

3

75

65

D

E

C

B

F

A

M00

080/

OS

200

_250

_01_

04K

C

OS200_K

[mm] D01 B01 D02 B02 D03 B03 D04 B04

A 154 130 154 130 154 130 154 130

B 191 167 191 167 191 167 191 167

C 198,5 198,5 198,5 198,5 198,5 198,5 198,5 198,5

D 40,5 40,5 40,5 40,5 40,5 40,5 40,5 40,5

E 36,5 36,5 36,5 36,5 36,5 36,5 36,5 36,5

F 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5

G 48,5 48,5 48,5 48,5 48,5 48,5 48,5 48,5

H - - 43,5 43,5 43,5 43,5 43,5 43,5

I 20 20 20 20 20 20 20 20

J 89,5 89,5 133 133 176,5 176,5 220 220

K 40 40 40 40 40 40 40 40

L 10 10 10 10 10 10 10 10

M 8,5 8,5 8,5 8,5 8,5 8,5 8,5 8,5

N 8,5 8,5 8,5 8,5 8,5 8,5 8,5 8,5

O 164,5 164,5 164,5 164,5 164,5 164,5 164,5 164,5

OS250_K

[mm] D01/B01 D02/B02 D03/B03 D04/B04

A 154 154 154 154

B 191 191 191 191

C 193 193 193 193

D 40,5 40,5 40,5 40,5

E 33,5 33,5 33,5 33,5

F 148,5 148,5 148,5 148,5

G 53,5 53,5 53,5 53,5

H - 54 54 54

I 25 25 25 25

J 99,5 153,5 207,5 261,5

K 45 45 45 45

L 11 11 11 11

M 11,5 11,5 11,5 11,5

N 4 4 4 4

O 162 162 162 162

OS200K

[mm] D01/B01 D02/B02 D03/B03 D04/B04

A1 144 144 144 144

A2 60,5 104 147,5 191

B1 138,5 138,5 138,5 138,5

B2 79,5 123 166,5 210

C1 108 108 108 108

C2 96,5 140 183,5 227

OS250K

[mm] D01 D02 D03 D04

A1 144 144 144 144

A2 70,5 124,5 178,5 232,5

B1 138,5 138,5 138,5 138,5

B2 89,5 143,5 197,5 251,5

C1 108 108 108 108

C2 106,5 106,5 214,5 268,5

Dimension drawings, IECFront operated switch fuses with direct mount handles

OS315_K and OS400_K

OS200_K and OS250_K

Page 83: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 83

Dimension drawings, IECFront operated switch fuses with direct mount handles

M00

229/

OS

600-

800_

01-0

4K

A

OS600-800

[mm/in] D/B01 D/B02 D/B03 D/B04

A 167/6,57 255/10,04 343/13,50 431/16,97

B 120/4,72 208/8,19 296/11,65 384/15,12

C 150/5,91 238/9,37 326/12,83 414/16,30

D 176/6,93 264/10,39 352/13,86 440/17,32

OS 630_K and OS 800_K

M00

229/

OS

600-

800_

01-0

4K

A

OS600-800

[mm/in] D/B01 D/B02 D/B03 D/B04

A 167/6,57 255/10,04 343/13,50 431/16,97

B 120/4,72 208/8,19 296/11,65 384/15,12

C 150/5,91 238/9,37 326/12,83 414/16,30

D 176/6,93 264/10,39 352/13,86 440/17,32

A1

281,10

26610,47

431,69

257,510,14

B1

562,20

2108,27

C1

OS1250D/B_

13,50,53

35614,02

42616,77

OS1200L_

200,79

22,50,89

110,43

110,43

60,24

37,51,48

13,50,53

421,65

mmin

28711,30

34613,62

2409,45

98,53,88

1104,33

501,97

126,54,98

A

*)

*)

*) N3- types

532,01

110,43

22,50,89

501,97

13,50,53

M85/16

451,77120,47

60,24

582,28

29411,57

933,66

60,24

1084,25

164,56,48

1104,33

1756,89

106

400

M00

231

/ O

S12

00-1

250_

01-0

4K

A

OS1200/1250

[mm/in] L01 L02 L03 L04

A 209 / 8,23 319 / 12,56 429 / 16,89 539 / 21,22

A1 166 / 6,54 276 / 10,87 386 / 15,20 496 / 19,53

B1 196 / 7,72 306 / 12,05 416 / 16,38 526 / 20,71

C1 222 / 8,74 332 / 13,07 442 / 17,40 552 / 21,73

OS 1200_K

A1

281,10

26610,47

431,69

257,510,14

B1

562,20

2108,27

C1

OS1250D/B_

13,50,53

35614,02

42616,77

OS1200L_

200,79

22,50,89

110,43

110,43

60,24

37,51,48

13,50,53

421,65

mmin

28711,30

34613,62

2409,45

98,53,88

1104,33

501,97

126,54,98

A

*)

*)

*) N3- types

532,01

110,43

22,50,89

501,97

13,50,53

M85/16

451,77120,47

60,24

582,28

29411,57

933,66

60,24

1084,25

164,56,48

1104,33

1756,89

106

400

M00

231

/ O

S12

00-1

250_

01-0

4K

A

OS1200/1250

[mm/in] L01 L02 L03 L04

A 209 / 8,23 319 / 12,56 429 / 16,89 539 / 21,22

A1 166 / 6,54 276 / 10,87 386 / 15,20 496 / 19,53

B1 196 / 7,72 306 / 12,05 416 / 16,38 526 / 20,71

C1 222 / 8,74 332 / 13,07 442 / 17,40 552 / 21,73

Page 84: Switch fuses OS and OSM - ABB

84 Dimension drawings | Switch fuses OS and OSM

Dimension drawings, IEC and UL/CSASide operated switch fuses

OS Mini

OS 40 Mini

108

110

154...166

45

EN 50022

3585

97

38

4,5

33

14,3 30,8 27,6

106

75...80

6

65

45

Ø66

9

OA 3G01OA 1G10 max 3+3

OSZ 4

74

4,5

33

30,8 27,6

142

9

OA 3G01OA 1G10 max 3+3

OA4B1C max 1+1

OSZ 4

35,6

OS 16...35FDS30_

OS 20...32FBS30_

OS 25...32FFS30_

OS 30FA_S30_

OS 16...35FDS40_

OS 20...32FBS40_

OS 25...32FFS40_

OS 30FA_S40_

ION

Test

31

OOFF

75...806

65

45

Ø66

ION

Test

OOFF

189...201

OS25FFS3010OS32FFS3014OS30FAS30JOS30FAS30CCOS16FDS3001OS35FDS3002

UL 198CCSA C22.2 No.106NFC63210,-63211

BS88-6IEC 60269-2-1OS32FBS30F1

BS88-2IEC 60269-2-1OS20FBS30A1OS32FBS30A1OS32FBS30A2

IEC 60269-2-1IEC 60269-3-1

BS88-6IEC 60269-2-1OS32FBS40F1

BS88-2IEC 60269-2-1OS20FBS40A1OS32FBS40A1OS32FBS40A2

IEC 60269-2-1IEC 60269-3-1NFC63210,-63211UL 198C

OS20FBS40A1F OS32FBS40A1FOS25FFS4010FOS32FFS4014FOS16FDS4001FOS35FDS4002FOS30FAJS40FOS30FACCS40F

55 55

120

14,3

164129

14...23

OA4B1C max 1+1

* *

*

* *

* *

*

OS20FBS40A1N1OS32FBS40A1N1OS32FBS40F1N1OS25FFS4010N1OS32FFS4014N1OS16FDS4001N1OS35FDS4002N1OS30FAJS40N1OS30FACCS40N1

M00

222/

OS

16-3

5F_S

A

36

105

50

EN 50022

3585

97

38

4,5

3314,3 30,8 27,6

115

75...80 6

65

45

Ø66

9

OA 3G01OA 1G10 max 3+3

OA4B1C max 1+1

OSZ 4

74

4,5

3330,8

151

9

OA 3G01OA 1G10 max 3+3

OA4B1C max 1+1

OSZ 4

35,6

OS 40FDS30000 OS40FDS40000

OS40FDS40000N1

61 61

141

14,3 27,6

DIN 000 DIN 000OS40FDS30000

I

O Test

N

N

126157...164

14...19

36

75...806

65

45

Ø66N

N

14...19

162193...200

56

OA 1G10OA 3G01max 2+2+2+2

M00

221/

OS

40F

DS

_

A

Page 85: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 85

57

95,5

43

88,5

53

33,4

20

8,5

5,5

114,5

M5

62,5 35

A (OS100-160G_S_)

D (OS100-160G_S_K)

Shaft depthMin 23Max 27

26,5

114

A1

34

110

B1

84

41,5

C1

M00

298/

OS

100_

160G

_S01

_04

A

93

50 2,5

140 C

B

OS100-160G

[mm] D/F01 D/F02 D/F03 D/F04 B01 B02 B03 B04

A 111,5 146,5 181,5 216,5 111,5 146,5 181,5 216,5

B 142 142 142 142 126,5 126,5 126,5 126,5

C 100 100 100 100 118 118 118 118

D 128,5 163,5 198,5 233,5 128,5 163,5 198,5 233,5

A1 71,5 106,5 141,5 176,5 71,5 106,5 141,5 176,5

B1 86,5 121,5 156,5 191,5 86,5 121,5 156,5 191,5

C1 101,5 136,5 171,5 206,5 101,5 136,5 171,5 206,5

M00

296/

OS

30_6

3G_0

1_04

S

A

1144,49

26,51,04

A1 B1

843,31

41,51,63

1003,94

1124,41

36,51,44

652,56

B

D C

A (OS30-63G_S_)

F (OS30_63G_S_K)

100 3,94

572,24

M53/16

532,08

Emmin

Min 23/0,91Max 27/1,06

Shaft depth

80,31

411,61

70,28

OS32-63G_

[mm] DS01 DS02 DS03 DS04 B/FS01 B/FS02 B/FS03 B/FS04

A 99,5 123 146,5 170 99,5 123 146,5 170

B 132,5 132,5 132,5 132,5 120,5 120,5 120,5 120,5

C - 23,5 23,5 23,5 - 23,5 23,5 23,5

D 56,5 56,5 56,5 56,5 56,5 56,5 56,5 56,5

E 30 30 30 30 30 30 30 30

F 116,5 140 163,5 187 116,5 140 163,5 187

A1 61,5 85 108,5 132 61,5 85 108,5 132

B1 91,5 115 138,5 162,5 91,5 115 138,5 162,5

OS60G_

[mm/in] JS01 JS02 JS03 JS04

A 109,5/4,31 144,5/5,69 179,5/7,07 214,5/8,44

B 130/5,12 130/5,12 130/5,12 130/5,12

C - 35/1,38 35/1,38 35/1,38

D 62/2,44 62/2,44 62/2,44 62/2,44

E 36/1,41 36/1,41 36/1,41 36/1,41

F 126,5/4,98 161,5/6,36 196,5/7,74 231,5/9,11

A1 67,5/2,66 102,5/4,04 137,5/5,41 172,5/6,79

B1 37,5/1,48 72,5/2,85 107,5/4,23 142,5/5,61

Dimension drawings, IEC and UL/CSASide operated switch fuses

OS32G...63G_S_

OS100G...160G_S_

M00

296/

OS

30_6

3G_0

1_04

S

A

1144,49

26,51,04

A1 B1

843,31

41,51,63

1003,94

1124,41

36,51,44

652,56

B

D C

A (OS30-63G_S_)

F (OS30_63G_S_K)

100 3,94

572,24

M53/16

532,08

Emmin

Min 23/0,91Max 27/1,06

Shaft depth

80,31

411,61

70,28

OS32-63G_

[mm] DS01 DS02 DS03 DS04 B/FS01 B/FS02 B/FS03 B/FS04

A 99,5 123 146,5 170 99,5 123 146,5 170

B 132,5 132,5 132,5 132,5 120,5 120,5 120,5 120,5

C - 23,5 23,5 23,5 - 23,5 23,5 23,5

D 56,5 56,5 56,5 56,5 56,5 56,5 56,5 56,5

E 30 30 30 30 30 30 30 30

F 116,5 140 163,5 187 116,5 140 163,5 187

A1 61,5 85 108,5 132 61,5 85 108,5 132

B1 91,5 115 138,5 162,5 91,5 115 138,5 162,5

OS60G_

[mm/in] JS01 JS02 JS03 JS04

A 109,5/4,31 144,5/5,69 179,5/7,07 214,5/8,44

B 130/5,12 130/5,12 130/5,12 130/5,12

C - 35/1,38 35/1,38 35/1,38

D 62/2,44 62/2,44 62/2,44 62/2,44

E 36/1,41 36/1,41 36/1,41 36/1,41

F 126,5/4,98 161,5/6,36 196,5/7,74 231,5/9,11

A1 67,5/2,66 102,5/4,04 137,5/5,41 172,5/6,79

B1 37,5/1,48 72,5/2,85 107,5/4,23 142,5/5,61

57

95,5

43

88,5

53

33,4

20

8,5

5,5

114,5

M5

62,5 35

A (OS100-160G_S_)

D (OS100-160G_S_K)

Shaft depthMin 23Max 27

26,5

114

A1

34

110

B1

84

41,5

C1

M00

298/

OS

100_

160G

_S01

_04

A

93

50 2,5

140 C

B

OS100-160G

[mm] D/F01 D/F02 D/F03 D/F04 B01 B02 B03 B04

A 111,5 146,5 181,5 216,5 111,5 146,5 181,5 216,5

B 142 142 142 142 126,5 126,5 126,5 126,5

C 100 100 100 100 118 118 118 118

D 128,5 163,5 198,5 233,5 128,5 163,5 198,5 233,5

A1 71,5 106,5 141,5 176,5 71,5 106,5 141,5 176,5

B1 86,5 121,5 156,5 191,5 86,5 121,5 156,5 191,5

C1 101,5 136,5 171,5 206,5 101,5 136,5 171,5 206,5

Page 86: Switch fuses OS and OSM - ABB

86 Dimension drawings | Switch fuses OS and OSM

M00

153/

OS

200-

250_

S01

-04_

C

OS200_, OS200_K

[mm/in] DS01 BS01 DS02 BS02 DS03 BS03 DS04 BS04

A 162,0/6,38 143,0/5,63 162,0/6,38 143,0/5,12 162,0/6,38 143,0/5,63 162,0/6,38 143,0/5,63

B 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48

C 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81

D 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33

E 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44

F 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69

G 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91

H -/- -/- 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71

I 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79

J 138,5/5,45 138,5/5,45 182,0/7,17 182,0/7,17 225,5/8,88 225,5/8,88 269,0/10,59 269,0/10,59

K 40,0/1,57 40,0/1,57 40,0/1,57 40,0/1,57 40,0/0,39 840,0/1,57 40,0/1,57 40,0/1,57

L 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39

M 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,4/0,33 8,5/0,33 8,5/0,33 8,5/0,33

N 121,5/4,78 121,5/4,78 165,0/6,50 165,0/6,50 208,5/8,21 208,5/8,21 252,0/9,92 252,0/9,92

A1 60,5/2,38 60,5/2,38 104,0/4,09 104,0/4,09 147,5/5,81 147,5/5,81 191,0/7,52 191,0/7,52

B1 79,5/3,13 79,5/3,13 123,0/4,84 123,0/4,84 166,5/6,56 166,5/6,56 210,0/8,27 210,0/8,27

C1 96,5/3,80 96,5/3,80 140,0/5,51 140,0/5,51 183,5/7,22 183,5/7,22 227,0/8,94 227,0/8,94

OS250_, OS250_K

[mm/in] DS01 BS01 DS02 BS02

A 154,0/6,06 154,0/6,06 154,0/6,06 154,0/6,06

B 162,0/6,38 162,0/6,38 162,0/6,38 162,0/6,38

C 193,0/7,60 193,0/7,60 193,0/7,60 193,0/7,60

D 4,0/0,16 4,0/0,16 4,0/0,16 4,0/0,16

E 33,5/1,32 33,5/1,32 33,5/1,32 33,5/1,32

F 148,5/5,85 148,5/5,85 148,5/5,85 148,5/5,85

G 53,5/2,11 53,5/2,11 53,5/2,11 53,5/2,11

H -/- 54,0/2,13 54,0/2,13 54,0/2,13

I 25,0/0,98 25,0/0,98 25,0/0,98 25,0/0,98

J 148,5/5,85 202,5/7,97 256,5/10,10 310,5/12,22

K 45,0/1,77 45,0/1,77 45,0/1,77 45,0/1,77

L 11,0/0,43 11,0/0,43 11,0/0,43 11,0/0,43

M 11,5/0,45 11,5/0,45 11,5/0,45 11,5/0,45

N 131,5/5,18 186,0/7,32 240,0/9,45 294,0/11,57

A1 70,5/2,78 124,5/4,90 178,5/7,03 232,5/9,15

B1 89,5/3,52 143,5/5,65 197,5/7,78 251,5/9,90

C1 106,5/4,19 214,5/8,44 268,5/10,57 322,5/12,70

30,12

75

OS 250:116/46

OS 200:110/464,33/1,81

4,57/1,81

53,52,11

E

C

F

A

6539,5

5,50,22

1,56 2,56

2,95

1264,96

722,83

OS 250: 53 / 2,09OS 200: 43 / 1,69

HG

N (OS200/250_)J (OS200/250_K)

B

K

L

D M702,76

I

1445,67

A1

8,50,33

1395,47

B1

17,50,69

1084,25

C1

26,51,04

1144,49

26,51,04

A1

341,34

1104,33

B1

843,31

41,51,63

C1

933,66

501,97

2,50,10

2208,66

1726,77

125,54,94

138,55,45

116,54,59

95,53,76

1003,94

572,24

A (OS100GJS_)

B (OS100GJS_K )

33,41,31

431,69

88,53,48

532,08

M53/16

62,52,46

351,38

200,79

Ø8,5 0,33

1505,91

110,43

mmin

Shaft depthMin 23/0,91Max 27/1,06

M00

296/

OS

30_6

3G_0

1_04

S

A

OS100G_

[mm/in] JS01 JS02 JS03 JS04

A 111,5/4,39 146,5/5,77 181,5/7,15 216,5/8,52

B 128,5/5,06 163,5/6,44 198,5/7,91 233,5/9,19

A1 71,5/2,81 106,5/4,19 141,5/5,57 176,5/6,95

B1 86,5/3,41 121,5/4,78 156,5/6,16 191,5/7,54

C1 101,5/4,00 136,5/5,37 171,5/6,75 206,5/8,13

Dimension drawings, IEC and UL/CSASide operated switch fuses

OS200...250_S_ (IEC only)

OS100GJS

M00

153/

OS

200-

250_

S01

-04_

C

OS200_, OS200_K

[mm/in] DS01 BS01 DS02 BS02 DS03 BS03 DS04 BS04

A 162,0/6,38 143,0/5,63 162,0/6,38 143,0/5,12 162,0/6,38 143,0/5,63 162,0/6,38 143,0/5,63

B 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48 164,5/6,48

C 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81 198,5/7,81

D 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33

E 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44 36,5/1,44

F 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69 144,5/5,69

G 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91 48,5/1,91

H -/- -/- 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71 43,5/1,71

I 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79 20,0/0,79

J 138,5/5,45 138,5/5,45 182,0/7,17 182,0/7,17 225,5/8,88 225,5/8,88 269,0/10,59 269,0/10,59

K 40,0/1,57 40,0/1,57 40,0/1,57 40,0/1,57 40,0/0,39 840,0/1,57 40,0/1,57 40,0/1,57

L 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39 10,0/0,39

M 8,5/0,33 8,5/0,33 8,5/0,33 8,5/0,33 8,4/0,33 8,5/0,33 8,5/0,33 8,5/0,33

N 121,5/4,78 121,5/4,78 165,0/6,50 165,0/6,50 208,5/8,21 208,5/8,21 252,0/9,92 252,0/9,92

A1 60,5/2,38 60,5/2,38 104,0/4,09 104,0/4,09 147,5/5,81 147,5/5,81 191,0/7,52 191,0/7,52

B1 79,5/3,13 79,5/3,13 123,0/4,84 123,0/4,84 166,5/6,56 166,5/6,56 210,0/8,27 210,0/8,27

C1 96,5/3,80 96,5/3,80 140,0/5,51 140,0/5,51 183,5/7,22 183,5/7,22 227,0/8,94 227,0/8,94

OS250_, OS250_K

[mm/in] DS01 BS01 DS02 BS02

A 154,0/6,06 154,0/6,06 154,0/6,06 154,0/6,06

B 162,0/6,38 162,0/6,38 162,0/6,38 162,0/6,38

C 193,0/7,60 193,0/7,60 193,0/7,60 193,0/7,60

D 4,0/0,16 4,0/0,16 4,0/0,16 4,0/0,16

E 33,5/1,32 33,5/1,32 33,5/1,32 33,5/1,32

F 148,5/5,85 148,5/5,85 148,5/5,85 148,5/5,85

G 53,5/2,11 53,5/2,11 53,5/2,11 53,5/2,11

H -/- 54,0/2,13 54,0/2,13 54,0/2,13

I 25,0/0,98 25,0/0,98 25,0/0,98 25,0/0,98

J 148,5/5,85 202,5/7,97 256,5/10,10 310,5/12,22

K 45,0/1,77 45,0/1,77 45,0/1,77 45,0/1,77

L 11,0/0,43 11,0/0,43 11,0/0,43 11,0/0,43

M 11,5/0,45 11,5/0,45 11,5/0,45 11,5/0,45

N 131,5/5,18 186,0/7,32 240,0/9,45 294,0/11,57

A1 70,5/2,78 124,5/4,90 178,5/7,03 232,5/9,15

B1 89,5/3,52 143,5/5,65 197,5/7,78 251,5/9,90

C1 106,5/4,19 214,5/8,44 268,5/10,57 322,5/12,70

30,12

75

OS 250:116/46

OS 200:110/464,33/1,81

4,57/1,81

53,52,11

E

C

F

A

6539,5

5,50,22

1,56 2,56

2,95

1264,96

722,83

OS 250: 53 / 2,09OS 200: 43 / 1,69

HG

N (OS200/250_)J (OS200/250_K)

B

K

L

D M702,76

I

1445,67

A1

8,50,33

1395,47

B1

17,50,69

1084,25

C1

26,51,04

1144,49

26,51,04

A1

341,34

1104,33

B1

843,31

41,51,63

C1

933,66

501,97

2,50,10

2208,66

1726,77

125,54,94

138,55,45

116,54,59

95,53,76

1003,94

572,24

A (OS100GJS_)

B (OS100GJS_K )

33,41,31

431,69

88,53,48

532,08

M53/16

62,52,46

351,38

200,79

Ø8,5 0,33

1505,91

110,43

mmin

Shaft depthMin 23/0,91Max 27/1,06

M00

296/

OS

30_6

3G_0

1_04

S

A

OS100G_

[mm/in] JS01 JS02 JS03 JS04

A 111,5/4,39 146,5/5,77 181,5/7,15 216,5/8,52

B 128,5/5,06 163,5/6,44 198,5/7,91 233,5/9,19

A1 71,5/2,81 106,5/4,19 141,5/5,57 176,5/6,95

B1 86,5/3,41 121,5/4,78 156,5/6,16 191,5/7,54

C1 101,5/4,00 136,5/5,37 171,5/6,75 206,5/8,13

Page 87: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 87

813,19

D

C

2309,06

401,56

56,52,22

50,20

9546,51,83 3,74

55,8/130,92,20/5,15

50,20

1646,46

170,67

A1

1596,26

261,02

B1

1084,25

26,51,04

C1

A (OS315/400_K)B (OS315/400_)

75,52,97

642,52

250,98

2017,91

823,23

58,52,30

11,50,45

1495,87

7,50,30

10,80,43

863,39

M00

154/

OS

315-

400_

S01

-04_

A

OS315, OS315_K, OS400, OS400_K

[mm] BS01 BS02 BS03 BS04

A 185,0 249,0 313,0 377,0

B 160,0 224,0 288,0 352,0

C 176,0 176,0 176,0 176,0

D 194,0 194,0 194,0 194,0

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

OS400_, OS400_K

[mm] DS01 DS02 DS03 DS04

A 185,0 249,0 313,0 377,0

B 160,0 224,0 288,0 352,0

C 193,0 193,0 193,0 193,0

D 166,0 166,0 166,0 166,0

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

813,19

D

C

2309,06

401,56

56,52,22

50,20

9546,51,83 3,74

55,8/130,92,20/5,15

50,20

1646,46

170,67

A1

1596,26

261,02

B1

1084,25

26,51,04

C1

A (OS315/400_K)B (OS315/400_)

75,52,97

642,52

250,98

2017,91

823,23

58,52,30

11,50,45

1495,87

7,50,30

10,80,43

863,39

M00

154/

OS

315-

400_

S01

-04_

A

OS315, OS315_K, OS400, OS400_K

[mm] BS01 BS02 BS03 BS04

A 185,0 249,0 313,0 377,0

B 160,0 224,0 288,0 352,0

C 176,0 176,0 176,0 176,0

D 194,0 194,0 194,0 194,0

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

OS400_, OS400_K

[mm] DS01 DS02 DS03 DS04

A 185,0 249,0 313,0 377,0

B 160,0 224,0 288,0 352,0

C 193,0 193,0 193,0 193,0

D 166,0 166,0 166,0 166,0

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

Dimension drawings, IECSide operated switch fuses

OS315...400_S_

OS630_S_ and OS800_S_

O

OFF

ON

O

OFF

ON

451,77

2329,14

A1

O

OFF

ON

602,36

2238,79

B1

732,87

1766,93

C1

O

OFF

ON

107,54,24

77,53,05 13,5

0,53

60,24 23

0,91

259,510,22

391,54

883,46

122,54,83

B (OS600/800_)

A (OS600/800_K)

2068,12

1164,57

M85/16

ON

OFF

O

60,2462

2,44

30612,06

501,97

2309,06

622,44

1445,67

2479,73

137/625,4/2,44

50,20

M00

146/

OS

600-

800_

S01

_-04

_ C

OS600/630/800_ , OS600/630/800_K

[mm] DS/BS01 DS/BS02 DS/BS03 DS/BS05

A 238 326/12,84 414 502

B 213 301/11,86 389 477

A1 147,5 235,5/9,28 323,5 411,5

B1 177,5 265,5/10,46 353,5 441,5

C1 203,5 291,5/11,48 379,5 467,5

O

OFF

ON

O

OFF

ON

451,77

2329,14

A1

O

OFF

ON

602,36

2238,79

B1

732,87

1766,93

C1

O

OFF

ON

107,54,24

77,53,05 13,5

0,53

60,24 23

0,91

259,510,22

391,54

883,46

122,54,83

B (OS600/800_)

A (OS600/800_K)

2068,12

1164,57

M85/16

ON

OFF

O

60,2462

2,44

30612,06

501,97

2309,06

622,44

1445,67

2479,73

137/625,4/2,44

50,20

M00

146/

OS

600-

800_

S01

_-04

_ C

OS600/630/800_ , OS600/630/800_K

[mm] DS/BS01 DS/BS02 DS/BS03 DS/BS05

A 238 326/12,84 414 502

B 213 301/11,86 389 477

A1 147,5 235,5/9,28 323,5 411,5

B1 177,5 265,5/10,46 353,5 441,5

C1 203,5 291,5/11,48 379,5 467,5

Page 88: Switch fuses OS and OSM - ABB

88 Dimension drawings | Switch fuses OS and OSM

8,5

A1

144

18

B1

138,5

26,5

C1

108126

72

20OS 250: 53OS 200: 43

HF G

A

M

KL

I

J

20

33,5

10,5

8,48,6

M5

*) OS_N3

*)

*)

14 min

45

36

(OXP 6X210)

65

75

OS 250:116/46OS 200:110/46 40,5

D

C

B

E

189...254

5,5

H

ø11

Back connection types:

12,5

59

49

3

M00

008/

OS

200_

250_

01_0

4

K /

M07

023

OS200_BB_

[mm] D01 B01 D02 B02 D03 B03 D04 B04

A 89,5 89,5 133 133 176,5 176,5 220 220

B 149 130 149 130 149 130 149 149

C 198,5 198,5 198,5 198,5 198,5 198,5 198,5 198,5

D 36,5 36,5 36,5 36,5 36,5 36,5 36,5 36,5

E 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5

F 48,5 48,5 48,5 48,5 48,5 48,5 48,5 48,5

G - - 43,5 43,5 43,5 43,5 43,5 43,5

H 20 20 20 20 20 20 20 20

I 40 40 40 40 40 40 40 40

J 10 10 10 10 10 10 10 10

K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4

L 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6

M 164,5 164,5 164,5 164,5 164,5 164,5 164,5 164,5

A1 60,5 60,5 104 104 147,5 147,5 191 191

B1 79,5 79,5 123 123 166,5 166,5 210 210

C1 96,5 96,5 140 140 183,5 183,5 227 227

OS250_BB_

[mm] D01/B01 D02/B02 D03/B03 D04/B04

A 99,5 153,5 207,5 261,5

B 154 154 154 154

C 193 193 193 193

D 33,5 33,5 33,5 33,5

E 148,5 148,5 148,5 148,5

F 53,5 53,5 53,5 53,5

G - 54 54 54

H 25 25 25 25

I 45 45 45 45

J 11 1 11 11

K 11,5 11,5 11,5 11,5

L 4 4 4 4

M 162 162 162 162

A1 70,5 124,5 178,5 232,5

B1 89,5 143,5 197,5 251,5

C1 106,5 160,5 214,5 268,5

Dimension drawings, IECSpecial connected switch fuses

OS200_12/22_ and OS250_12/22 (BB)

M00

014/

OS

200_

250_

11_2

2 K

A2

144

A1

C2

108

C1

138,5

B2

B1

72

G I

J

144

LK

M

N FE

H

20

10,58,48,6

33,5

M5

*) OS_N3:

*)

*)14 min

6

D

A

(OXP 6X210)

B

C

40,5 3

45

65

75

OS 250:116/46OS 200:110/46

126

189...254

5,5

G

ø11

Back connection types:

12,5

3

59

49

OS200

[mm] D11 B11 D12 B12 D13 B13 D22 B22

A 149 130 149 130 141 130 149 130

B 199 199 199 199 199 199 199 199

C 36,5 36,5 36,3 36,5 36,5 36,5 36,5 36,5

D 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5

E 92 92 92 92 92 92 135,5 135,5

F 43,5 43,5 43,5 43,5 43,5 43,5 43,5 43,5

G 20 20 20 20 20 20 20 20

H 132 132 175,5 175,5 219 219 219 219

I 40 40 40 40 40 40 40 40

J 10 10 10 10 10 10 10 10

K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4

L 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6

M 165 165 165 165 165 165 165 165

N 80 80 80 80 80 80 80 80

A1 104 104 147,5 147,5 191 191 191 191

A2 52 52 52 52 52 52 95,5 95,5

B1 123 123 166,5 166,5 210 210 210 210

B2 61,5 61,5 61,5 61,5 61,5 61,5 105 105

C1 140 140 183,5 183,5 227 227 227 227

C2 70 70 70 70 70 70 113,5 113,5

OS250

[mm] D11 D12 D13 D22

A 154 154 154 154

B 193 193 193 193

C 33,5 33,5 33,5 33,5

D 148,5 148,5 148,5 148,5

E 112,5 112,5 112,5 161

F 54 54 54 54

G 25 25 25 25

H 152 206 260 260

I 45 45 45 45

J 11 11 11 11

K 11,5 11,5 11,5 11,5

L 4 4 4 4

M 162 162 162 162

N 90 90 90 90

A1 124 178 232 232

A2 62 62 62 116

B1 143 197 251 251

B2 71,5 71,5 71,5 125,5

C1 160 214 268 268

C2 80 80 80 134

M00

014/

OS

200_

250_

11_2

2 K

A2

144

A1

C2

108

C1

138,5

B2

B1

72

G I

J

144

LK

M

N FE

H

20

10,58,48,6

33,5

M5

*) OS_N3:

*)

*)14 min

6

D

A

(OXP 6X210)

B

C

40,5 3

45

65

75

OS 250:116/46OS 200:110/46

126

189...254

5,5

G

ø11

Back connection types:

12,5

3

59

49

OS200

[mm] D11 B11 D12 B12 D13 B13 D22 B22

A 149 130 149 130 141 130 149 130

B 199 199 199 199 199 199 199 199

C 36,5 36,5 36,3 36,5 36,5 36,5 36,5 36,5

D 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5

E 92 92 92 92 92 92 135,5 135,5

F 43,5 43,5 43,5 43,5 43,5 43,5 43,5 43,5

G 20 20 20 20 20 20 20 20

H 132 132 175,5 175,5 219 219 219 219

I 40 40 40 40 40 40 40 40

J 10 10 10 10 10 10 10 10

K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4

L 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6

M 165 165 165 165 165 165 165 165

N 80 80 80 80 80 80 80 80

A1 104 104 147,5 147,5 191 191 191 191

A2 52 52 52 52 52 52 95,5 95,5

B1 123 123 166,5 166,5 210 210 210 210

B2 61,5 61,5 61,5 61,5 61,5 61,5 105 105

C1 140 140 183,5 183,5 227 227 227 227

C2 70 70 70 70 70 70 113,5 113,5

OS250

[mm] D11 D12 D13 D22

A 154 154 154 154

B 193 193 193 193

C 33,5 33,5 33,5 33,5

D 148,5 148,5 148,5 148,5

E 112,5 112,5 112,5 161

F 54 54 54 54

G 25 25 25 25

H 152 206 260 260

I 45 45 45 45

J 11 11 11 11

K 11,5 11,5 11,5 11,5

L 4 4 4 4

M 162 162 162 162

N 90 90 90 90

A1 124 178 232 232

A2 62 62 62 116

B1 143 197 251 251

B2 71,5 71,5 71,5 125,5

C1 160 214 268 268

C2 80 80 80 134

OS200_03/04_ and OS250_03/04 (BB)

8,5

A1

144

18

B1

138,5

26,5

C1

108126

72

20OS 250: 53OS 200: 43

HF G

A

M

KL

I

J

20

33,5

10,5

8,48,6

M5

*) OS_N3

*)

*)

14 min

45

36

(OXP 6X210)

65

75

OS 250:116/46OS 200:110/46 40,5

D

C

B

E

189...254

5,5

H

ø11

Back connection types:

12,5

59

49

3

M00

008/

OS

200_

250_

01_0

4

K /

M07

023

OS200_BB_

[mm] D01 B01 D02 B02 D03 B03 D04 B04

A 89,5 89,5 133 133 176,5 176,5 220 220

B 149 130 149 130 149 130 149 149

C 198,5 198,5 198,5 198,5 198,5 198,5 198,5 198,5

D 36,5 36,5 36,5 36,5 36,5 36,5 36,5 36,5

E 144,5 144,5 144,5 144,5 144,5 144,5 144,5 144,5

F 48,5 48,5 48,5 48,5 48,5 48,5 48,5 48,5

G - - 43,5 43,5 43,5 43,5 43,5 43,5

H 20 20 20 20 20 20 20 20

I 40 40 40 40 40 40 40 40

J 10 10 10 10 10 10 10 10

K 8,4 8,4 8,4 8,4 8,4 8,4 8,4 8,4

L 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6

M 164,5 164,5 164,5 164,5 164,5 164,5 164,5 164,5

A1 60,5 60,5 104 104 147,5 147,5 191 191

B1 79,5 79,5 123 123 166,5 166,5 210 210

C1 96,5 96,5 140 140 183,5 183,5 227 227

OS250_BB_

[mm] D01/B01 D02/B02 D03/B03 D04/B04

A 99,5 153,5 207,5 261,5

B 154 154 154 154

C 193 193 193 193

D 33,5 33,5 33,5 33,5

E 148,5 148,5 148,5 148,5

F 53,5 53,5 53,5 53,5

G - 54 54 54

H 25 25 25 25

I 45 45 45 45

J 11 1 11 11

K 11,5 11,5 11,5 11,5

L 4 4 4 4

M 162 162 162 162

A1 70,5 124,5 178,5 232,5

B1 89,5 143,5 197,5 251,5

C1 106,5 160,5 214,5 268,5

C00

0011

/OS

315-

400_

11_2

2

D /

M07

024

A1

1646,46

A2

B1

1596,26

B2

C1

1285,04

C2

DC

642,52

1174,61

1937,60

250,98 10,8

0,437,50,30

642,5258,5

2,30

mmin

0,4511,5

M53/16

*) OS_N3

*)

*)

451,77

120,47

953,74

B

230...325 (OXP 12x250)9,06...12,80

A

2309,06

50,20401,57

min 200,79

43,51,7155,8/130,9

2,20/5,15

50,20

813,19

50,20

451,77

250,98

381,50

ø110,43

Back connection types:

12,50,49

943,70

OS315-400_BB_

[mm] B11 B12 B13 B21 B22

A 176 176 176 176 176

B 194 194 194 194 194

C 140 140 140 204 204

D 190 254 318 254 318

OS400_BB_

[mm] D11 D12 D13 D21 D22

A 193 193 193 193 193

B 166 166 166 166 166

C 140 140 140 204 204

D 190 254 318 254 318

OS315_BB_

[mm] B11 B12 B21 B22 B13

A1 163 227 227 291 291

A2 81,5 81,5 145,5 145,5 81,5

B1 181 245 245 309 309

B2 90,5 90,5 154,5 154,5 90,5

C1 199 263 263 327 327

C2 99,5 99,5 163,5 163,5 99,5

OS400_BB_

[mm] B11/D11 B12/D12 B21/D21 B22/D22 B13/D13

A1 163 227 227 291 291

A2 81,5 81,5 145,5 145,5 81,5

B1 181 245 245 309 309

B2 90,5 90,5 154,5 154,5 90,5

C1 199 263 263 327 327

C2 99,5 99,5 163,5 163,5 99,5

Page 89: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 89

C00

0011

/OS

315-

400_

11_2

2

D /

M07

024

A1

1646,46

A2

B1

1596,26

B2

C1

1285,04

C2

DC

642,52

1174,61

1937,60

250,98 10,8

0,437,50,30

642,5258,5

2,30

mmin

0,4511,5

M53/16

*) OS_N3

*)

*)

451,77

120,47

953,74

B

230...325 (OXP 12x250)9,06...12,80

A

2309,06

50,20401,57

min 200,79

43,51,7155,8/130,9

2,20/5,15

50,20

813,19

50,20

451,77

250,98

381,50

ø110,43

Back connection types:

12,50,49

943,70

OS315-400_BB_

[mm] B11 B12 B13 B21 B22

A 176 176 176 176 176

B 194 194 194 194 194

C 140 140 140 204 204

D 190 254 318 254 318

OS400_BB_

[mm] D11 D12 D13 D21 D22

A 193 193 193 193 193

B 166 166 166 166 166

C 140 140 140 204 204

D 190 254 318 254 318

OS315_BB_

[mm] B11 B12 B21 B22 B13

A1 163 227 227 291 291

A2 81,5 81,5 145,5 145,5 81,5

B1 181 245 245 309 309

B2 90,5 90,5 154,5 154,5 90,5

C1 199 263 263 327 327

C2 99,5 99,5 163,5 163,5 99,5

OS400_BB_

[mm] B11/D11 B12/D12 B21/D21 B22/D22 B13/D13

A1 163 227 227 291 291

A2 81,5 81,5 145,5 145,5 81,5

B1 181 245 245 309 309

B2 90,5 90,5 154,5 154,5 90,5

C1 199 263 263 327 327

C2 99,5 99,5 163,5 163,5 99,5

C00

0012

/O

S31

5_40

0_01

_04

D

/ M

0702

5

A1

1646,46

170,67

B1

1596,26

261,02

C1

1285,04

351,38

A

75,52,97

642,52

250,98

1937,60

823,23

58,52,3011,50,45

1405,51

7,50,30

10,80,43

281,10

mmin

M53/16

*) OS_N3

*)

*)

45

813,19

1,7712

0,47

953,74

C

230...325 (OXP 12x250)9,06...12,80

B

2309,06

401,56

43,51,71

50,20

min 200,79

55,8/130,92,20/5,15

50,20

250,98

381,50

ø110,43

Back connection types:

12,50,49

50,20

943,70

451,77

OS315 - 400_BB_

[mm] B01 B02 B03 B04

A 127 191 255 319

B 176 176 176 176

C 194 194 194 194

OS400_BB_

[mm] B01/D01 B02/D02 B03/D03 B04/D04

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

OS400_BB_

[mm] D01 D02 D03 D04

A 127 191 255 319

B 193 193 193 193

C 166 166 166 166

OS315_BB_

[mm] B01 B02 B03 B04

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

Dimension drawings, IECSpecial connected switch fuses

OS315_12/22_ and OS400_12/22 (BB)

OS315_03/04_ and OS400_03/04 (BB)

C00

0012

/O

S31

5_40

0_01

_04

D

/ M

0702

5

A1

1646,46

170,67

B1

1596,26

261,02

C1

1285,04

351,38

A

75,52,97

642,52

250,98

1937,60

823,23

58,52,3011,50,45

1405,51

7,50,30

10,80,43

281,10

mmin

M53/16

*) OS_N3

*)

*)

45

813,19

1,7712

0,47

953,74

C

230...325 (OXP 12x250)9,06...12,80

B

2309,06

401,56

43,51,71

50,20

min 200,79

55,8/130,92,20/5,15

50,20

250,98

381,50

ø110,43

Back connection types:

12,50,49

50,20

943,70

451,77

OS315 - 400_BB_

[mm] B01 B02 B03 B04

A 127 191 255 319

B 176 176 176 176

C 194 194 194 194

OS400_BB_

[mm] B01/D01 B02/D02 B03/D03 B04/D04

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

OS400_BB_

[mm] D01 D02 D03 D04

A 127 191 255 319

B 193 193 193 193

C 166 166 166 166

OS315_BB_

[mm] B01 B02 B03 B04

A1 98,5 162,5 226,5 290,5

B1 116,5 180,5 244,5 308,5

C1 134,5 198,5 262,5 326,5

C00

0011

/OS

315-

400_

11_2

2

D /

M07

024

A1

1646,46

A2

B1

1596,26

B2

C1

1285,04

C2

DC

642,52

1174,61

1937,60

250,98 10,8

0,437,50,30

642,5258,5

2,30

mmin

0,4511,5

M53/16

*) OS_N3

*)

*)

451,77

120,47

953,74

B

230...325 (OXP 12x250)9,06...12,80

A

2309,06

50,20401,57

min 200,79

43,51,7155,8/130,9

2,20/5,15

50,20

813,19

50,20

451,77

250,98

381,50

ø110,43

Back connection types:

12,50,49

943,70

OS315-400_BB_

[mm] B11 B12 B13 B21 B22

A 176 176 176 176 176

B 194 194 194 194 194

C 140 140 140 204 204

D 190 254 318 254 318

OS400_BB_

[mm] D11 D12 D13 D21 D22

A 193 193 193 193 193

B 166 166 166 166 166

C 140 140 140 204 204

D 190 254 318 254 318

OS315_BB_

[mm] B11 B12 B21 B22 B13

A1 163 227 227 291 291

A2 81,5 81,5 145,5 145,5 81,5

B1 181 245 245 309 309

B2 90,5 90,5 154,5 154,5 90,5

C1 199 263 263 327 327

C2 99,5 99,5 163,5 163,5 99,5

OS400_BB_

[mm] B11/D11 B12/D12 B21/D21 B22/D22 B13/D13

A1 163 227 227 291 291

A2 81,5 81,5 145,5 145,5 81,5

B1 181 245 245 309 309

B2 90,5 90,5 154,5 154,5 90,5

C1 199 263 263 327 327

C2 99,5 99,5 163,5 163,5 99,5

Page 90: Switch fuses OS and OSM - ABB

90 Dimension drawings | Switch fuses OS and OSM

Dimension drawings, IECSpecial connected switch fuses

142162

97

28

63

3

18590 55

56

56

242

35

122 100

156

35

ø 5,5 M644M

0036

5/O

S16

0GD

21LR

_AM

0036

4/O

S16

0GD

12LR

_B

32

45

65

35

122 100

156

44

35

M6

97

28

63

3

69

142162

18555 90

242

56

56

ø 5,5

OS125G...160GD12LR (LR)

OS125G...160GD21LR (LR)

Page 91: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 91

Dimension drawings, IECSpecial connected switch fuses

OS125G...160GD22LR (LR)

OS125G...160GB12LR (LR)

69

142162

97

28

63

3

18555 90

56

56

ø 5,5242

35

122 118

141

44M6

35

M00

361/

OS

160G

B12

LR_A

69

177197

97

28

63

3

22090 90

56

56

ø 5,5

277

35

150100

156

35

35

7 44

M6

M00

366/

OS

160G

D22

LR_A

Page 92: Switch fuses OS and OSM - ABB

92 Dimension drawings | Switch fuses OS and OSM

OS125G...160GB21LR (LR)

69

142162

97

28

63

3

5590

56

56

ø 5,5242

35

122 118

141

44M6

35

M00

362/

OS

160G

B21

LR_A

OS125G...160GB22LR (LR)

69

177197

97

28

63

3

22090 90

56

56

M6

35150

118

141

35

35

7 44

277M00

363/

OS

160G

B22

LR_A

Dimension drawings, IECSpecial connected switch fuses

Page 93: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 93

56

56

228 193

438

122

ø6

101

OS125G...160G_21LR + OSS160G 3LS

101

228

61

9691

56

473

228 Ø6

OS125G...160G_22LR + OSS160G 4LSGT

GT

Dimension drawings, IECSpecial connected switch fuses

Page 94: Switch fuses OS and OSM - ABB

94 Dimension drawings | Switch fuses OS and OSM

Dimension drawings, IECSpecial connected switch fuses

OS200B12_ and OS250_12_ (LR)

OS200B21_ and OS250_21_ (LR)

6

50

5067,5

67,5

25

11

11,5

4525 11

4

45 5453

34,3 85

79,5 133,5

25,5

5

59,5

Back left

Back right

M8

21,6

69,6108

3

3

42,5

45

50

155,5

218.

..283

(OX

P 6

X21

0)5445 45

25 12,5

148,5 150

203,553

148121,5

252

11

42,5

101,565 45

36

184

108

151

105

94

306

175,5206

149,5137 191

M00

120/

OS

250_

12B

L-B

R

B

/ M

0702

6

OS200B...250_LR, 3-pole

OS200B12LR

OS250B12LR

OS250D12LR

6

50

5067,5

67,5

25

11

11,5

4525 11

4

45 5453

34,3 85

79,5 133,5

25,5

5

59,5

Back left

Back right

M8

21,6

69,6108

3

3

42,5

45

50

155,5

218.

..283

(OX

P 6

X21

0)

5445 45

25 12,5

148,5 150

203,553

148121,5

252

11

42,5

101,565 45

36

184

108

151

105

94

306

175,5206

149,5137 191

M00

120/

OS

250_

12B

L-B

R

B

/ M

0702

6

OS200B...250_LR, 3-pole

OS200B12LR

OS250B12LR

OS250D12LR

6

50

67,5

67,5

25

11

11,5

542511

4

45 45

34,3 85

79,5133,5

25,5

5

59,5

BL

BR

M845

21,6

69,6108

3

3

42,5

50

155,5 101,5

218.

..283

(OX

P 6

X21

0)

65 45

36

54

25

45 45

12,5

148,5 150

149,553

53

148175,5

306

11

42,5

184

108

205

105

252151

121,594

203,5191 137

M00

119/

OS

250_

21B

D-B

R

B

/ M

0702

7

OS200B...250_LR, 3-pole

OS200B21LR

OS250B21LR

OS250D21LR

6

50

67,5

67,5

25

11

11,5

542511

4

45 45

34,3 85

79,5133,5

25,5

5

59,5

BL

BR

M845

21,6

69,6108

3

3

42,5

50

155,5 101,5

218.

..283

(OX

P 6

X21

0)

65 45

36

54

25

45 45

12,5

148,5 150

149,553

53

148175,5

306

11

42,5

184

108

205

105

252151

121,594

203,5191 137

M00

119/

OS

250_

21B

D-B

R

B

/ M

0702

7

OS200B...250_LR, 3-pole

OS200B21LR

OS250B21LR

OS250D21LR

Page 95: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 95

OS315B12_ and OS400_12_ (LR)

OS315B21_ and OS400_21_ (LR)

Dimension drawings, IEC Special connected switch fuses

M00

130/

OS

400_

12B

L-B

R

C

/ M

0702

8

50

25

58,5 64 22064

58,5126

7,511,5

155,5

M8

23

47

50

23

5

40 51

110

68,75

B

5,5

11

28

255.

..350

(OX

P 1

2X25

0)

5012,543

112 176

120,5 184,5

11061,5

5

A

95 45

36

99

150

6925

69

163

12,5 6458,558,5

104

11

204140169

271,5233

335,5

64168 232

2025

21

9

BR

BL

29

OS315B...400_LR

A B

OS315B12LR 201 194

OS400B12LR 201 194

OS400D12LR 218 166

M00

130/

OS

400_

12B

L-B

R

C

/ M

0702

8

50

25

58,5 64 22064

58,5126

7,511,5

155,5

M8

23

47

50

23

5

40 51

110

68,75

B

5,5

11

28

255.

..350

(OX

P 1

2X25

0)

5012,543

112 176

120,5 184,5

11061,5

5

A

95 45

36

99

150

6925

69

163

12,5 6458,558,5

104

11

204140169

271,5233

335,5

64168 232

2025

21

9

BR

BL

29

OS315B...400_LR

A B

OS315B12LR 201 194

OS400B12LR 201 194

OS400D12LR 218 166

OS315B...400_LR

A B

OS315B21LR 201 194

OS400B21LR 201 194

OS400D21LR 218 166M00

127/

OS

400_

21B

L-B

R

C

/ M

0702

9

50

2551

64

64

220 155,5126 11,5

7,5

M847

50

23

23

5

40

110

68,75

B

5,5

11

28

255.

..350

(OX

P 1

2X25

0)

233

50

140169

204

184,5 120,5

11061,5

5

A

150

69 25

69

163

25

95 45

36

99

104

11

64 58,5 58,5

58,564 58,5

232 168

176 112

271,5335

29 20

12,5

BR

BL

21

9

OS315B...400_LR

A B

OS315B21LR 201 194

OS400B21LR 201 194

OS400D21LR 218 166M00

127/

OS

400_

21B

L-B

R

C

/ M

0702

9

50

2551

64

64

220 155,5126 11,5

7,5

M847

50

23

23

5

40

110

68,75

B

5,5

11

28

255.

..350

(OX

P 1

2X25

0)

233

50

140169

204

184,5 120,5

11061,5

5

A

150

69 25

69

163

25

95 45

36

99

104

11

64 58,5 58,5

58,564 58,5

232 168

176 112

271,5335

29 20

12,5

BR

BL

21

9

Page 96: Switch fuses OS and OSM - ABB

96 Dimension drawings | Switch fuses OS and OSM

OS315B22_N2 and OS400_22_N2 (LR)

Dimension drawings, IECSpecial connected switch fuses

M00

126/

OS

400-

22B

L-B

RN

2

C /

M07

030

25

50

2541,1 7,5

64

6411,5

11104

116,2 58,558,564

53022

68,7

33

505

50

47

110

33,5

M8

B

85

85

75

11

5,5

11

28

255.

..350

(OX

P 1

2X25

0)

203,5176,5

183,5 183,5

11061,5

5012,5

5

A

95 45

36

64 58,5 58,5 64

153,5 153,5

72,580

80

122,5

125

176,5203,5

233 233334 334

219231,5

219231,5

29 2025

31

9

BR

BL

OS315B...400_LR

A B

OS315B22LR 201 194

OS400B22LR 201 194

OS400D22LR 218 166

M00

126/

OS

400-

22B

L-B

RN

2

C /

M07

030

25

50

2541,1 7,5

64

6411,5

11104

116,2 58,558,564

53022

68,7

33

505

50

47

110

33,5

M8

B

85

85

75

11

5,5

11

28

255.

..350

(OX

P 1

2X25

0)

203,5176,5

183,5 183,5

11061,5

5012,5

5

A

95 45

36

64 58,5 58,5 64

153,5 153,5

72,580

80

122,5

125

176,5203,5

233 233334 334

219231,5

219231,5

29 2025

31

9

BR

BL

OS315B...400_LR

A B

OS315B22LR 201 194

OS400B22LR 201 194

OS400D22LR 218 166

M00

293

/ O

SM

32-6

3-M

A

OSM32-63_M_

[mm] D3 D4 B3 B4

A 23,5 23,5 23,5 23,5

A1 122 122 122 122

A2 187,5 211 187,5 211

B 229 252,5 229 252,5

C 100 100 100 100

D 136,5 136,5 124,5 124,5

Page 97: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 97

M00

293

/ O

SM

32-6

3-M

A

OSM32-63_M_

[mm] D3 D4 B3 B4

A 23,5 23,5 23,5 23,5

A1 122 122 122 122

A2 187,5 211 187,5 211

B 229 252,5 229 252,5

C 100 100 100 100

D 136,5 136,5 124,5 124,5

M00

294

/ O

SM

100-

160-

M

A

OSM100-160_M_

[mm] D/F3 D/F4 B3 B4

A 35 35 35 35

A1 122 122 122 122

A2 272 307 272 307

B 290 325 290 325

C 100 100 118 188

D 146 146 130,5 130,5

Dimension drawings, IECMotorized switch fuses

OSM32...63_M_

OSM100...160_M_

M00

294

/ O

SM

100-

160-

M

A

OSM100-160_M_

[mm] D/F3 D/F4 B3 B4

A 35 35 35 35

A1 122 122 122 122

A2 272 307 272 307

B 290 325 290 325

C 100 100 118 188

D 146 146 130,5 130,5

M00

293

/ O

SM

32-6

3-M

A

OSM32-63_M_

[mm] D3 D4 B3 B4

A 23,5 23,5 23,5 23,5

A1 122 122 122 122

A2 187,5 211 187,5 211

B 229 252,5 229 252,5

C 100 100 100 100

D 136,5 136,5 124,5 124,5

Page 98: Switch fuses OS and OSM - ABB

98 Dimension drawings | Switch fuses OS and OSM

M00

198

/ O

SM

250-

M

B

OSM250_M_

[mm] D3/B3 D4/B4

A 54 54

A1 118 118

A2 332 386

B 354 408

C 148,5 148,5

D 156 156

Dimension drawings, IECMotorized switch fuses

OSM200_M_

OSM250_M_

M00

198

/ O

SM

250-

M

B

OSM250_M_

[mm] D3/B3 D4/B4

A 54 54

A1 118 118

A2 332 386

B 354 408

C 148,5 148,5

D 156 156

M00

1997

OS

M20

0-M

B

OSM200_M_

[mm] B3 B4 D3 D4

A 43,5 43,5 43,5 43,5

A1 118 118 118 118

A2 301,5 345 301,5 345

B 323,5 367 323,5 367

C 144,5 144,5 144,5 144,5

D 132 132 151 151

M00

1997

OS

M20

0-M

B

OSM200_M_

[mm] B3 B4 D3 D4

A 43,5 43,5 43,5 43,5

A1 118 118 118 118

A2 301,5 345 301,5 345

B 323,5 367 323,5 367

C 144,5 144,5 144,5 144,5

D 132 132 151 151

Page 99: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 99

M00

206

/ O

SM

639-

800-

M

B

OSM630-800_M_

[mm] D3/B3 D4/B4

A 88 88

A1 180 180

A2 465,5 553,5

B 486,5 574,5

Dimension drawings, IECMotorized switch fuses

OSM315...400_M_

OSM630...800_M_

M00

206

/ O

SM

639-

800-

M

B

OSM630-800_M_

[mm] D3/B3 D4/B4

A 88 88

A1 180 180

A2 465,5 553,5

B 486,5 574,5

M00

199/

OS

M31

5-40

0-M

C

OSM315_M_

[mm] B3 B4

A 64 64

A1 136 136

A2 382 446

B 404 468

C 194 194

D 178,5 178,5

OSM400_M_

[mm] B3 B4 D3 D4

A 64 64 64 64

A1 136 136 136 136

A2 382 446 382 446

B 404 468 404 468

C 194 194 166 166

D 178,5 178,5 196,5 196,5M00

199/

OS

M31

5-40

0-M

C

OSM315_M_

[mm] B3 B4

A 64 64

A1 136 136

A2 382 446

B 404 468

C 194 194

D 178,5 178,5

OSM400_M_

[mm] B3 B4 D3 D4

A 64 64 64 64

A1 136 136 136 136

A2 382 446 382 446

B 404 468 404 468

C 194 194 166 166

D 178,5 178,5 196,5 196,5

Page 100: Switch fuses OS and OSM - ABB

100 Dimension drawings | Switch fuses OS and OSM

M00

238

/ O

SM

1250

-M

C OSM1250_M_

[mm] B3/D3 B4/D4

A 110 110

A1 230 230

A2 569,5 679,5

B 599,5 709,5

OSM1250_M_

Dimension drawings, IECMotorized switch fuses

M00

238

/ O

SM

1250

-M

C OSM1250_M_

[mm] B3/D3 B4/D4

A 110 110

A1 230 230

A2 569,5 679,5

B 599,5 709,5

Page 101: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 101

Dimension drawingsAccessories

Plastic handles

Handle type B shaft diameter

[mm]

Length L

[mm]

OH_45J6 6 45

OH_65J6 6 65

OH_95J12 12 95

OH_125J12 12 125

OH_145J12 12 145

OH_175J12 12 175

OH_275J12 12 275

Door drilling for OH_ handles:

Door drilling for OHM_OHM_

Stainless steel handles

M00

133/

13O

HM

45-2

75L-

A/K

E00

020

5353

Ø 31 Ø5

45

37 51

B

69

L

Ø Handle type B shaft diameter Lenght L

[mm] [mm]

OHM65L6 6 65

OHM125L12 12 125

OHM175L12 12 175

OHM275L12 12 275

M07

015

Handle type Length L

[mm]

OH_274J12 274

OH_330J12 330

Handle type Length L

[mm]

OHB150J12P 300

OHB200J12P 400

M00

134

/ 1

3/O

H-1

50-2

00J1

2P

A

69,4

54 7180

L

ø

Ø31 Ø5

45°

5353

M00

134

/ 1

3/O

H-1

50-2

00J1

2P

A

69,4

54 7180

L

ø

Ø31 Ø5

45°

5353

Page 102: Switch fuses OS and OSM - ABB

102 Dimension drawings | Switch fuses OS and OSM

Dimension drawingsAccessories

YASDA7, 8 (A=220) Door drilling for YASDA:

Metallic handles

Minimum distance L between the hinge and the rotating shaft

hinge

shaft

Sizes [A] Length L

[mm]

Handle type

30...250 60 OH_65J6

315...400 95 OH_95J12

630...800 150 OH_125J12, OH_145J12

630...800 175 OH_175J12

630...800 275 OH_275J12

630...800 220 YASDA7, 8

1200...1250 274 OH_274J12

1200...1250 330 OH_330J12

6 and 8-pole switch fuses OETLZW9OESAZW2

Page 103: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Dimension drawings 103

Dimension drawingsAccessories

OETLZW11

OETLZW11

A 210+(0...11)x20 mm

Change-over and by-pass switch fuses

OTZW 26

OETLZW12, 13OETLZW11

OETLZW12, 13

OETLZW12 OETLZW13

A 210+(0...18)x20 mm 210+(0...18)x20 mm

B 250+(0...18)x20 mm

D 220 mm 320 mm

OTZW25

A 210+(0...18)x20mm

OTZW26

A 210+(0...9)x20mm

B 210+(0...9)x20mm

A00

213_

B

Mechanical interlock

OETLZX3, 14, 15

OETLZW3 OETLZW14 OETLZW15

A 300 250 500

B 31 31 36

S001

20A

OTZW25

A 210+(0...18)x20mm

OTZW26

A 210+(0...9)x20mm

B 210+(0...9)x20mm

A00

213_

B

OTZW 25

OTZW10, 24

OTZW10 OTZW24

A 206 114

B 190 100

C 6 5

D 30 25

Page 104: Switch fuses OS and OSM - ABB

104 Contact functions | Switch fuses OS and OSM

Contact functions

Handle indications and functions – The handle indicates the position of the contacts with

complete reliability in all situations. If the contacts are welded together, the handle doesn´t reach the OFF-position but remains between ON and OFF, maintaining the door interlock and padlocking is not possible to do.

– When operating the switch fuse to the Test-position with a test handle the testauxiliary contacts change position. The main contacts remain open.

ON and OFF-functions of main and auxiliary contacts

-45˚ 0˚ 30˚ 60˚ 90˚

Main contactsNO auxiliary contact

NC auxiliary contact

NO auxiliary contact

NC auxiliary contact

OS Mini

OA4B1C, 1 NO-NC

OA1G10, 1NO

OA3G01, 1NC

-45˚ 0˚ 30˚ 60˚ 90˚

Main contactsNO auxiliary contact

NC auxiliary contact

NO auxiliary contact

NC auxiliary contact

OS30...63

OS100...200

Places of auxiliary

contacts and Test ind.

Main contactsNO auxiliary contact

NC auxiliary contact

NO auxiliary contact

NC auxiliary contact

-45˚ 0˚ 30˚ 60˚ 90˚

closeopen

closeopen

closeopen

OA1G10, 1NO

OA3G01, 1NC

OA1G10, 1NO

OA3G01, 1NC

S01

201A

OA1G10, 1NO

OA3G01, 1NC

OA1G10, 1NO

OA3G01, 1NC

Change over

contacts

OA1G10, 1NO

OA3G01, 1NC

Main contactsNO auxiliary contact

NC auxiliary contact

NO auxiliary contact

NC auxiliary contact

-45˚ 0˚ 30˚ 60˚ 90˚

Test ind NO

Test ind NC

Test OFFO

ONI

closeopen

openclose

Main contacts

NO auxiliary contact

NC auxiliary contact

0˚ 30˚ 60˚ 90˚

OFFO

ONI

α

OO

II

α

α

α

α

Test OFFO

ONI

MCB-10 + OESAZX169, 1NO

MCB-01 + OESAZX169, 1NC

Test OFFO

ONI

OO

II

-45˚ 0˚ 30˚ 60˚ 90˚ α

Test OFFO

ONI

Test OFFO

ONI

OO

II

OO

II

OO

II

OO

II

OO

II

OO

II

Main contacts

NO test contactsinside the mechanism

NC test contactsinside the mechanism

NO test indication contacts inside the mechanism

NC test indication contacts inside the mechanism

NO auxiliary contacts in the module on the side of the switch

NC auxiliary contacts in the module on the side of the switch

OS63G...160G

OS200...400

Example

1

2

1

2

Page 105: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Contact functions 105

Contact functionsS

0718

8A

OA1G10, 1NO

OA3G01, 1NC

OA1G10, 1NO

OA3G01, 1NC

+ OEA28

OA1G10, 1NO

OA3G01, 1NC

OO

II

-45˚ 0˚ 30˚ 60˚ 90˚ α

Test OFFO

ONI

OO

II

OO

II

OO

II

OO

II

OO

II

OO

II

Main contacts

NO test contactsinside the mechanism

NO early operation test contacts inside the mechanism1)

NC test contacts inside the mechanism

NC early operation test contacts inside the mechanism1)

NO test indication contacts inside the mechanism

NC test indication contacts inside the mechanism

OS/OSM32G...1250

OS_, OSM

OS_

OSM_

NO auxiliary contacts in the module on the side of the switch2)

NC auxiliary contacts in the module on the side of the switch2)

OO

II

OO

II

1) OS/OSM1200...1250 only2) Also OSM32G...1250 mounted on the right side of the switch

Page 106: Switch fuses OS and OSM - ABB

106 Index | Switch fuses OS and OSM

Index

Type Order number Description Page

MCB-01 1SCA022150R5370 Auxiliary contacts 54

MCB-10 1SCA022150R5110 Auxiliary contacts 54

OA1G10 1SCA022353R4970 Auxiliary contacts 54

OA1G10 1SCA022353R4970 Auxiliary contacts 55

OA1G10AU 1SCA022436R7910 Auxiliary contacts 54

OA1G10AU 1SCA022436R7910 Auxiliary contacts 55

OA3G01 1SCA022456R7410 Auxiliary contacts 54

OA3G01 1SCA022456R7410 Auxiliary contacts 55

OA3G01AU 1SCA022819R5260 Auxiliary contacts 54

OA3G01AU 1SCA022819R5260 Auxiliary contacts 55

OA4B01 1SCA022276R9210 Auxiliary contacts 54

OA4B10 1SCA022276R9050 Auxiliary contacts 54

OA4B1C 1SCA022193R0150 Auxiliary contacts 54

OEA28 1SCA022714R8810 Module for auxiliary contacts 56

OEA30L 1SCA131816R1001 Mounting plate 57

OEA30R 1SCA131817R1001 Mounting plate 57

OESAZW2 1SCA022078R1600 Conversion kits 65

OETLZK19 1SCA022093R1850 Adapters for extension socket 53

OETLZW11 1SCA022078R0030 Conversion kits 65

OETLZW12 1SCA022078R0200 Conversion kits 65

OETLZW13 1SCA022078R0460 Conversion kits 65

OETLZW14 1SCA022077R3410 Conversion kits 65

OETLZW15 1SCA022081R9340 Conversion kits 65

OETLZW16 1SCA022095R2070 Cam attachment 69

OETLZW3 1SCA022049R0380 Conversion kits 65

OETLZW5 1SCA022052R3900 Cam attachment 69

OETLZW9 1SCA022061R3300 Conversion kits 65

OETLZX95 1SCA022083R5620 Shaft extension socket 53

OEZNL1 1SCA022723R7400 Solid links 59

OEZNL10 1SCA116437R1001 Solid links 59

OEZNL8 1SCA113998R1001 Solid links 59

OEZXU14/3 1SCA100361R1001 Terminal angle 61

OEZXU14/4 1SCA101082R1001 Terminal angle 61

OEZXU68/3 1SCA121380R1001 Terminal angle 61

OEZXU68/4 1SCA121379R1001 Terminal angle 61

OFAE506 1SCA128175R1001 Fuse replacement handles 50

OFAW00 1SCA022003R9680 Solid links 59

OFAW1 1SCA022003R9760 Solid links 59

OFAW2 1SCA022003R9840 Solid links 59

OFAW3 1SCA022003R9920 Solid links 59

OFD110EA 1SCA121775R1001 Electronic fuse monitor 67

OFD500EA 1SCA121776R1001 Electronic fuse monitor 67

OFM240 1SCA022579R1340 Electronic fuse monitor 67

OFM260 1SCA022459R8560 Electronic fuse monitor 67

OFM600 1SCA022579R1260 Electronic fuse monitor 67

OFM690 1SCA022459R8480 Electronic fuse monitor 67

OFMZX2 1SCA022475R9910 Electronic fuse monitor 67

OFS260 1SCA022716R0180 Electronic fuse monitor 67

OFS690 1SCA022715R9920 Electronic fuse monitor 67

OHB125J12 1SCA022381R1560 Pistol handles 47

OHB125J12T 1SCA022652R2220 Pistol handles 47

OHB145J12 1SCA022381R2110 Pistol handles 47

OHB145J12E00S 1SCA022679R9700 Pistol handles 49

OHB145J12T 1SCA022652R2570 Pistol handles 47

OHB150J12P 1SCA022865R9430 Optional handles 48

OHB175J12 1SCA022381R2450 Pistol handles 47

Type Order number Description Page

OHB175J12T 1SCA022708R0740 Pistol handles 47

OHB200J12P 1SCA022865R9510 Optional handles 48

OHB200J12PT 1SCA106510R1001 Optional handles 48

OHB274J12 1SCA115920R1001 Optional handles 48

OHB274J12T 1SCA120250R1001 Optional handles 48

OHB330J12 1SCA115922R1001 Optional handles 48

OHB330J12T 1SCA120252R1001 Optional handles 48

OHB4 1SCA022439R4050 Direct mount handles 50

OHB45J6 1SCA022380R8770 Pistol handles 47

OHB45J6T 1SCA109870R1001 Pistol handles 47

OHB65J6 1SCA022380R9660 Pistol handles 47

OHB65J6E00S 1SCA022382R9850 Pistol handles 49

OHB65J6T 1SCA022399R8110 Pistol handles 47

OHB65J6TE00S 1SCA109016R1001 Pistol handles 49

OHB80J6 1SCA022381R0240 Pistol handles 47

OHB80J6T 1SCA022399R8290 Pistol handles 47

OHB95J12 1SCA022381R0830 Pistol handles 47

OHB95J12T 1SCA022736R1750 Pistol handles 47

OHG125J12 1SCA022381R1640 Pistol handles 47

OHG145J12 1SCA022381R2290 Pistol handles 47

OHG175J12 1SCA022381R2610 Pistol handles 47

OHG45J6 1SCA022380R8850 Pistol handles 47

OHG65J6 1SCA022380R9740 Pistol handles 47

OHG65J6E00S 1SCA022383R4510 Pistol handles 49

OHG65J6T 1SCA022456R9620 Pistol handles 47

OHG65J6TE00S 1SCA109014R1001 Pistol handles 49

OHG95J12 1SCA022381R0910 Pistol handles 47

OHY125J12 1SCA022381R1720 Pistol handles 47

OHY125J12T 1SCA022652R2310 Pistol handles 47

OHY145J12 1SCA022381R2370 Pistol handles 47

OHY145J12T 1SCA022652R2650 Pistol handles 47

OHY150J12P 1SCA101586R1001 Optional handles 48

OHY175J12 1SCA022381R2700 Pistol handles 47

OHY200J12P 1SCA101587R1001 Optional handles 48

OHY200J12PT 1SCA111512R1001 Optional handles 48

OHY274J12 1SCA115919R1001 Optional handles 48

OHY330J12 1SCA115921R1001 Optional handles 48

OHY45J6 1SCA022380R8930 Pistol handles 47

OHY65J6 1SCA022380R9820 Pistol handles 47

OHY65J6E00S 1SCA022382R9930 Pistol handles 49

OHY65J6T 1SCA022456R9540 Pistol handles 47

OHY65J6TE00S 1SCA022688R0140 Pistol handles 49

OHY95J12 1SCA022381R1050 Pistol handles 47

OHY95J12T 1SCA022736R1910 Pistol handles 47

OS100GB03N3P 1SCA125531R1001 Front operated switch fuse 28

OS100GB03N3P-42 1SCA129907R1001 Switch fuse, BS-type 31

OS100GB03P 1SCA114613R1001 Front operated switch fuse 28

OS100GB03P-42 1SCA128217R1001 Switch fuse, BS-type 31

OS100GB04N1P 1SCA114614R1001 Front operated switch fuse 28

OS100GB12N3P-42 1SCA129910R1001 Switch fuse, BS-type 31

OS100GJ03 1SCA115436R1001 Front operated fusible disconnect

switches

40

OS100GJ04F 1SCA115438R1001 Front operated fusible disconnect

switches

40

OS100GJ12 1SCA115665R1001 Front operated fusible disconnect

switches

40

Page 107: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Index 107

Type Order number Description Page

OS100GJ22F 1SCA115668R1001 Front operated fusible disconnect

switches

40

OS100GJS30 1SCA115971R1001 Side operated fusible disconnect

switches

42

OS100GJS40F 1SCA115972R1001 Side operated fusible disconnect

switches

42

OS1200L02 1SCA116924R1001 Front operated fusible disconnect

switches

41

OS1200L03 1SCA105467R1001 Front operated fusible disconnect

switches

41

OS1200L04F 1SCA105465R1001 Front operated fusible disconnect

switches

41

OS1250B02P 1SCA114070R1001 Front operated switch fuse 30

OS1250B03K 1SCA108715R1001 Front operated switch fuse 33

OS1250B03N3P 1SCA107936R1001 Front operated switch fuse 30

OS1250B03P 1SCA105250R1001 Front operated switch fuse 30

OS1250D02P 1SCA114051R1001 Front operated switch fuse 21

OS1250D03K 1SCA108718R1001 Front operated switch fuse 23

OS1250D03N3P 1SCA107932R1001 Front operated switch fuse 21

OS1250D03P 1SCA105475R1001 Front operated switch fuse 21

OS1250D04FP 1SCA105473R1001 Front operated switch fuse 21

OS1250D04N2K 1SCA108719R1001 Front operated switch fuse 23

OS1250D04N2P 1SCA105248R1001 Front operated switch fuse 21

OS1250DA02P 1SCA114059R1001 Front operated switch fuse 21

OS1250DA03K 1SCA108720R1001 Front operated switch fuse 23

OS1250DA03N3P 1SCA107934R1001 Front operated switch fuse 21

OS1250DA03P 1SCA105238R1001 Front operated switch fuse 21

OS1250DA04FP 1SCA105240R1001 Front operated switch fuse 21

OS1250DA04N2K 1SCA108721R1001 Front operated switch fuse 23

OS1250DA04N2P 1SCA105243R1001 Front operated switch fuse 21

OS125GB03BBP 1SCA120783R1001 Special connected switch fuse 36

OS125GB03N3P 1SCA122008R1001 Front operated switch fuse 28

OS125GB03N3P-42 1SCA129912R1001 Switch fuse, BS-type 31

OS125GB03N3P-42 1SCA129912R1001 Front operated switch fuse 32

OS125GB03P 1SCA115634R1001 Front operated switch fuse 28

OS125GB03P-42 1SCA128215R1001 Switch fuse, BS-type 31

OS125GB03P-42 1SCA128215R1001 Front operated switch fuse 32

OS125GB04BBN1P 1SCA122597R1001 Special connected switch fuse 36

OS125GB04N1P 1SCA115901R1001 Front operated switch fuse 28

OS125GB12LRP 1SCA120258R1001 Special connected switch fuse 37

OS125GB12N3P-42 1SCA129914R1001 Switch fuse, BS-type 31

OS125GB21LRP 1SCA120261R1001 Special connected switch fuse 37

OS125GB22LRP 1SCA120265R1001 Special connected switch fuse 37

OS125GBS30K 1SCA116400R1001 Side operated switch fuse 34

OS125GBS40N1K 1SCA115926R1001 Side operated switch fuse 34

OS125GD02P 1SCA116716R1001 Front operated switch fuse 19

OS125GD03BBP 1SCA120802R1001 Special connected switch fuse 26

OS125GD03K 1SCA116878R1001 Front operated switch fuse 22

OS125GD03P 1SCA115639R1001 Front operated switch fuse 19

OS125GD04BBN2P 1SCA120806R1001 Special connected switch fuse 26

OS125GD04FK 1SCA116741R1001 Front operated switch fuse 22

OS125GD04FP 1SCA115686R1001 Front operated switch fuse 19

OS125GD04N2K 1SCA116740R1001 Front operated switch fuse 22

OS125GD04N2P 1SCA115877R1001 Front operated switch fuse 19

OS125GD12LRP 1SCA120062R1001 Special connected switch fuse 27

OS125GD21LRP 1SCA120255R1001 Special connected switch fuse 27

OS125GD22LRP 1SCA120263R1001 Special connected switch fuse 27

OS125GDS30K 1SCA115933R1001 Side operated switch fuse 24

OS125GDS40N2K 1SCA115934R1001 Side operated switch fuse 24

OS125GF02P 1SCA116727R1001 Front operated switch fuses 38

OS125GF03P 1SCA115602R1001 Front operated switch fuses 38

Type Order number Description Page

OS125GF04FP 1SCA115606R1001 Front operated switch fuses 38

OS125GF04N1P 1SCA115888R1001 Front operated switch fuses 38

OS125GFS30K 1SCA115944R1001 Side operated switch fuse 39

OS125GFS40FK 1SCA115946R1001 Side operated switch fuse 39

OS125GFS40N1K 1SCA115945R1001 Side operated switch fuse 39

OS160GB03BBP 1SCA120657R1001 Special connected switch fuse 36

OS160GB03K 1SCA116753R1001 Front operated switch fuse 32

OS160GB03N3P 1SCA122010R1001 Front operated switch fuse 28

OS160GB03N3P-42 1SCA129916R1001 Switch fuse, BS-type 31

OS160GB03N3P-42 1SCA129916R1001 Front operated switch fuse 32

OS160GB03P 1SCA115413R1001 Front operated switch fuse 28

OS160GB03P-42 1SCA128213R1001 Switch fuse, BS-type 31

OS160GB03P-42 1SCA128213R1001 Front operated switch fuse 32

OS160GB04BBN1P 1SCA122598R1001 Special connected switch fuse 36

OS160GB04N1K 1SCA116754R1001 Front operated switch fuse 32

OS160GB04N1P 1SCA115896R1001 Front operated switch fuse 28

OS160GB12LRP 1SCA120271R1001 Special connected switch fuse 37

OS160GB12N3P-42 1SCA129919R1001 Switch fuse, BS-type 31

OS160GB21LRP 1SCA120273R1001 Special connected switch fuse 37

OS160GB22LRP 1SCA120277R1001 Special connected switch fuse 37

OS160GBS30K 1SCA115927R1001 Side operated switch fuse 34

OS160GBS40N1K 1SCA115928R1001 Side operated switch fuse 34

OS160GD02P 1SCA116717R1001 Front operated switch fuse 19

OS160GD03BBP 1SCA120655R1001 Special connected switch fuse 26

OS160GD03K 1SCA116742R1001 Front operated switch fuse 22

OS160GD03P 1SCA115399R1001 Front operated switch fuse 19

OS160GD04BBN2P 1SCA120661R1001 Special connected switch fuse 26

OS160GD04FK 1SCA116880R1001 Front operated switch fuse 22

OS160GD04FP 1SCA115402R1001 Front operated switch fuse 19

OS160GD04N2K 1SCA116743R1001 Front operated switch fuse 22

OS160GD04N2P 1SCA115882R1001 Front operated switch fuse 19

OS160GD12LRP 1SCA120267R1001 Special connected switch fuse 27

OS160GD21LRP 1SCA120294R1001 Special connected switch fuse 27

OS160GD22LRP 1SCA120275R1001 Special connected switch fuse 27

OS160GDS30K 1SCA115935R1001 Side operated switch fuse 24

OS160GDS40N2K 1SCA115939R1001 Side operated switch fuse 24

OS200B02P 1SCA022769R7820 Front operated switch fuse 29

OS200B03BBP 1SCA102082R1001 Special connected switch fuse 36

OS200B03K 1SCA022763R6950 Front operated switch fuse 33

OS200B03N3P 1SCA022750R0620 Front operated switch fuse 29

OS200B03P 1SCA022709R9330 Front operated switch fuse 29

OS200B04BBN2P 1SCA102123R1001 Special connected switch fuse 36

OS200B12LRP 1SCA022854R2910 Special connected switch fuse 37

OS200B21LRP 1SCA022854R3050 Special connected switch fuse 37

OS200B22LRP 1SCA022854R4290 Special connected switch fuse 37

OS200BS30K 1SCA022870R7850 Side operated switch fuse 35

OS200BS40N2K 1SCA022870R8230 Side operated switch fuse 35

OS200D02P 1SCA022759R9220 Front operated switch fuse 20

OS200D03BBP 1SCA102150R1001 Special connected switch fuse 26

OS200D03K 1SCA022764R7130 Front operated switch fuse 23

OS200D03N3P 1SCA022749R8710 Front operated switch fuse 20

OS200D03P 1SCA022709R9500 Front operated switch fuse 20

OS200D04BBN2P 1SCA102139R1001 Special connected switch fuse 26

OS200D04FP 1SCA022725R4750 Front operated switch fuse 20

OS200D04N2K 1SCA022768R7430 Front operated switch fuse 23

OS200D04N2P 1SCA022709R9680 Front operated switch fuse 20

OS200DS30K 1SCA022871R1450 Side operated switch fuse 25

OS200DS40FK 1SCA022871R1610 Side operated switch fuse 25

OS200DZ03P 1SCA022797R3440 Front operated switch fuse 20

OS200DZ04N2P 1SCA022820R9230 Front operated switch fuse 20

Page 108: Switch fuses OS and OSM - ABB

108 Index | Switch fuses OS and OSM

Type Order number Description Page

OS200J02 1SCA107591R1001 Front operated fusible disconnect

switches

41

OS200J03 1SCA022733R6130 Front operated fusible disconnect

switches

41

OS200J04F 1SCA022758R9340 Front operated fusible disconnect

switches

41

OS250B02P 1SCA022769R9440 Front operated switch fuse 29

OS250B03BBP 1SCA102168R1001 Special connected switch fuse 36

OS250B03K 1SCA022763R6010 Front operated switch fuse 33

OS250B03N3P 1SCA022750R8010 Front operated switch fuse 29

OS250B03P 1SCA022750R6660 Front operated switch fuse 29

OS250B04BBN2P 1SCA102164R1001 Special connected switch fuse 36

OS250B12LRP 1SCA022854R5690 Special connected switch fuse 37

OS250B21LRP 1SCA022854R5850 Special connected switch fuse 37

OS250B22LRP 1SCA022854R7210 Special connected switch fuse 37

OS250BS30K 1SCA022870R8660 Side operated switch fuse 35

OS250BS40N2K 1SCA022870R9040 Side operated switch fuse 35

OS250D02P 1SCA022760R0170 Front operated switch fuse 20

OS250D03BBP 1SCA102190R1001 Special connected switch fuse 26

OS250D03K 1SCA022763R6360 Front operated switch fuse 23

OS250D03N3P 1SCA022749R9430 Front operated switch fuse 20

OS250D03P 1SCA022719R0090 Front operated switch fuse 20

OS250D04BBN2P 1SCA102205R1001 Special connected switch fuse 26

OS250D04FP 1SCA022726R8620 Front operated switch fuse 20

OS250D04N2K 1SCA022763R6440 Front operated switch fuse 23

OS250D04N2P 1SCA022719R2380 Front operated switch fuse 20

OS250D12LRP 1SCA022852R8410 Special connected switch fuse 27

OS250D21LRP 1SCA022852R8500 Special connected switch fuse 27

OS250D22LRP 1SCA022853R0310 Special connected switch fuse 27

OS250DS30K 1SCA022871R2260 Side operated switch fuse 25

OS250DS40FK 1SCA022871R2420 Side operated switch fuse 25

OS25FFS3010 1SCA108639R1001 Side operated switch fuse 39

OS25FFS3010-2 1SCA108808R1001 Side operated switch fuse 39

OS30FACC12 1SCA108813R1001 Front operated fusible disconnect

switches

40

OS30FACC22F 1SCA108819R1001 Front operated fusible disconnect

switches

40

OS30FACCS30 1SCA108822R1001 Side operated fusible disconnect

switches

42

OS30FAJ12 1SCA108824R1001 Front operated fusible disconnect

switches

40

OS30FAJ22F 1SCA108829R1001 Front operated fusible disconnect

switches

40

OS30FAJS30 1SCA108834R1001 Side operated fusible disconnect

switches

42

OS315B02P 1SCA022817R3450 Front operated switch fuse 29

OS315B03BBP 1SCA102222R1001 Special connected switch fuse 36

OS315B03K 1SCA022763R6520 Front operated switch fuse 33

OS315B03N3P 1SCA022753R8940 Front operated switch fuse 29

OS315B03P 1SCA022719R0680 Front operated switch fuse 29

OS315B04BBN2P 1SCA102225R1001 Special connected switch fuse 36

OS315B12LRP 1SCA022854R8790 Special connected switch fuse 37

OS315B21LRP 1SCA022854R8870 Special connected switch fuse 37

OS315B22LRP 1SCA022855R0000 Special connected switch fuse 37

OS315BS30K 1SCA022870R9470 Side operated switch fuse 35

OS315BS40N2K 1SCA022870R9800 Side operated switch fuse 35

OS32GB02P 1SCA116721R1001 Front operated switch fuse 28

OS32GB03K 1SCA116744R1001 Front operated switch fuse 32

OS32GB03P 1SCA115259R1001 Front operated switch fuse 28

OS32GB04N1K 1SCA116856R1001 Front operated switch fuse 32

OS32GB04N1P 1SCA114610R1001 Front operated switch fuse 28

Type Order number Description Page

OS32GBS30K 1SCA115918R1001 Side operated switch fuse 34

OS32GBS40N1K 1SCA115923R1001 Side operated switch fuse 34

OS32GD02P 1SCA116714R1001 Front operated switch fuse 19

OS32GD03K 1SCA116733R1001 Front operated switch fuse 22

OS32GD03P 1SCA115189R1001 Front operated switch fuse 19

OS32GD04FK 1SCA116737R1001 Front operated switch fuse 22

OS32GD04FP 1SCA115196R1001 Front operated switch fuse 19

OS32GD04N2K 1SCA116734R1001 Front operated switch fuse 22

OS32GD04N2P 1SCA115193R1001 Front operated switch fuse 19

OS32GDS30K 1SCA115929R1001 Side operated switch fuse 24

OS32GDS40N1K 1SCA115930R1001 Side operated switch fuse 24

OS32GDS40N2K 1SCA116402R1001 Side operated switch fuse 24

OS400B02P 1SCA022813R7220 Front operated switch fuse 29

OS400B03BBP 1SCA102252R1001 Special connected switch fuse 36

OS400B03K 1SCA022763R6790 Front operated switch fuse 33

OS400B03N3P 1SCA022753R9160 Front operated switch fuse 29

OS400B03P 1SCA022719R0840 Front operated switch fuse 29

OS400B04BBN2P 1SCA102248R1001 Special connected switch fuse 36

OS400B12LRP 1SCA022855R1400 Special connected switch fuse 37

OS400B21LRP 1SCA022855R1580 Special connected switch fuse 37

OS400B22LRP 1SCA022855R2710 Special connected switch fuse 37

OS400BS30K 1SCA022871R0210 Side operated switch fuse 35

OS400BS40N2K 1SCA022871R0640 Side operated switch fuse 35

OS400D02P 1SCA022811R2740 Front operated switch fuse 20

OS400D03BBP 1SCA102260R1001 Special connected switch fuse 26

OS400D03K 1SCA022779R5410 Front operated switch fuse 23

OS400D03N3P 1SCA022753R9320 Front operated switch fuse 20

OS400D03P 1SCA022719R0250 Front operated switch fuse 20

OS400D04BBN2P 1SCA102289R1001 Special connected switch fuse 26

OS400D04FP 1SCA022753R7110 Front operated switch fuse 20

OS400D04N2K 1SCA022763R7250 Front operated switch fuse 23

OS400D04N2P 1SCA022719R2460 Front operated switch fuse 20

OS400D12LRP 1SCA022853R2280 Special connected switch fuse 27

OS400D21LRP 1SCA022853R2360 Special connected switch fuse 27

OS400D22LRP 1SCA022853R4140 Special connected switch fuse 27

OS400DS30K 1SCA022871R2930 Side operated switch fuse 25

OS400DS40FK 1SCA022871R3150 Side operated switch fuse 25

OS400J02 1SCA107592R1001 Front operated fusible disconnect

switches

41

OS400J03 1SCA022755R0810 Front operated fusible disconnect

switches

41

OS400J04F 1SCA022755R3660 Front operated fusible disconnect

switches

41

OS50GF02P 1SCA118345R1001 Front operated switch fuses 38

OS50GF03P 1SCA115492R1001 Front operated switch fuses 38

OS50GF04FP 1SCA115498R1001 Front operated switch fuses 38

OS50GF04N1P 1SCA115495R1001 Front operated switch fuses 38

OS50GFS30K 1SCA116404R1001 Side operated switch fuse 39

OS50GFS40FK 1SCA116425R1001 Side operated switch fuse 39

OS50GFS40N1K 1SCA116013R1001 Side operated switch fuse 39

OS600J02 1SCA107593R1001 Front operated fusible disconnect

switches

41

OS600J03 1SCA022825R8610 Front operated fusible disconnect

switches

41

OS600J04F 1SCA022839R3900 Front operated fusible disconnect

switches

41

OS60GJ03 1SCA115866R1001 Front operated fusible disconnect

switches

40

OS60GJ04F 1SCA115445R1001 Front operated fusible disconnect

switches

40

Page 109: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Index 109

Type Order number Description Page

OS60GJ12 1SCA122981R1001 Front operated fusible disconnect

switches

40

OS60GJ22F 1SCA115468R1001 Front operated fusible disconnect

switches

40

OS60GJS30 1SCA116051R1001 Side operated fusible disconnect

switches

42

OS60GJS40F 1SCA115970R1001 Side operated fusible disconnect

switches

42

OS630B02P 1SCA113529R1001 Front operated switch fuse 30

OS630B03K 1SCA108708R1001 Front operated switch fuse 33

OS630B03N3P 1SCA100860R1001 Front operated switch fuse 30

OS630B03P 1SCA022825R5850 Front operated switch fuse 30

OS630BS30K 1SCA108148R1001 Side operated switch fuse 35

OS630BS40N2K 1SCA108151R1001 Side operated switch fuse 35

OS630D02P 1SCA107745R1001 Front operated switch fuse 21

OS630D03K 1SCA108704R1001 Front operated switch fuse 23

OS630D03N3P 1SCA100858R1001 Front operated switch fuse 21

OS630D03P 1SCA022825R2830 Front operated switch fuse 21

OS630D04FP 1SCA022825R4610 Front operated switch fuse 21

OS630D04N2K 1SCA108705R1001 Front operated switch fuse 23

OS630D04N2P 1SCA022825R4290 Front operated switch fuse 21

OS630DS30K 1SCA108136R1001 Side operated switch fuse 25

OS630DS40FK 1SCA108138R1001 Side operated switch fuse 25

OS63GB02P 1SCA116854R1001 Front operated switch fuse 28

OS63GB03K 1SCA116745R1001 Front operated switch fuse 32

OS63GB03P 1SCA115235R1001 Front operated switch fuse 28

OS63GB04N1K 1SCA116746R1001 Front operated switch fuse 32

OS63GB04N1P 1SCA115238R1001 Front operated switch fuse 28

OS63GBS30K 1SCA115924R1001 Side operated switch fuse 34

OS63GBS40N1K 1SCA115979R1001 Side operated switch fuse 34

OS63GD02P 1SCA116715R1001 Front operated switch fuse 19

OS63GD03K 1SCA116738R1001 Front operated switch fuse 22

OS63GD03P 1SCA115207R1001 Front operated switch fuse 19

OS63GD04FK 1SCA116739R1001 Front operated switch fuse 22

OS63GD04FP 1SCA115228R1001 Front operated switch fuse 19

OS63GD04N2K 1SCA116876R1001 Front operated switch fuse 22

OS63GD04N2P 1SCA115209R1001 Front operated switch fuse 19

OS63GDS30K 1SCA115931R1001 Side operated switch fuse 24

OS63GDS40N1K 1SCA115932R1001 Side operated switch fuse 24

OS63GDS40N2K 1SCA116403R1001 Side operated switch fuse 24

OS800B02P 1SCA022837R6480 Front operated switch fuse 30

OS800B03K 1SCA108713R1001 Front operated switch fuse 33

OS800B03N3P 1SCA100861R1001 Front operated switch fuse 30

OS800B03P 1SCA022825R7550 Front operated switch fuse 30

OS800BS30K 1SCA108084R1001 Side operated switch fuse 35

OS800BS40N2K 1SCA108087R1001 Side operated switch fuse 35

OS800D02P 1SCA022837R2650 Front operated switch fuse 21

OS800D03K 1SCA108725R1001 Front operated switch fuse 23

OS800D03N3P 1SCA100859R1001 Front operated switch fuse 21

OS800D03P 1SCA022825R4880 Front operated switch fuse 21

OS800D04FP 1SCA022825R5000 Front operated switch fuse 21

OS800D04N2K 1SCA108722R1001 Front operated switch fuse 23

OS800D04N2P 1SCA022825R5180 Front operated switch fuse 21

OS800DS30K 1SCA108099R1001 Side operated switch fuse 25

OS800DS40FK 1SCA108101R1001 Side operated switch fuse 25

OS800L02 1SCA116920R1001 Front operated fusible disconnect

switches

41

OS800L03 1SCA022825R9760 Front operated fusible disconnect

switches

41

OS800L04F 1SCA022839R5350 Front operated fusible disconnect

switches

41

Type Order number Description Page

OSB160/4 1SCA131820R1001 Phase barries 59

OSB160/6 1SCA131821R1001 Phase barries 59

OSB250/4 1SCA131822R1001 Phase barries 59

OSB250/6 1SCA131823R1001 Phase barries 59

OSD25P3 1SCA022192R9060 Blown fuse indicators (DPMM) 68

OSD25P4 1SCA022196R9520 Blown fuse indicators (DPMM) 68

OSGD125P3 1SCA115690R1001 Blown fuse indicators (DPMM) 68

OSGD125P4 1SCA115692R1001 Blown fuse indicators (DPMM) 68

OSGD50P3 1SCA116401R1001 Blown fuse indicators (DPMM) 68

OSGD50P4 1SCA115689R1001 Blown fuse indicators (DPMM) 68

OSGZD1 1SCA115688R1001 Mounting accessories 70

OSM100GB3M230C 1SCA116679R1001 Motorized switch fuse 44

OSM100GB4N1M230C 1SCA118779R1001 Motorized switch fuse 44

OSM1250B3M230C 1SCA112552R1001 Motorized switch fuse 44

OSM1250B3N3M230C 1SCA112550R1001 Motorized switch fuse 44

OSM1250B4N1M230C 1SCA118795R1001 Motorized switch fuse 44

OSM1250D3M230C 1SCA112549R1001 Motorized switch fuse 43

OSM1250D3N3M230C 1SCA112547R1001 Motorized switch fuse 43

OSM1250D4N2M230C 1SCA118850R1001 Motorized switch fuse 43

OSM1250DA3M230C 1SCA112546R1001 Motorized switch fuse 43

OSM1250DA3N3M230C 1SCA112544R1001 Motorized switch fuse 43

OSM1250DA4N2M230C 1SCA118851R1001 Motorized switch fuse 43

OSM125GB3M230C 1SCA116677R1001 Motorized switch fuse 44

OSM125GB4N1M230C 1SCA118780R1001 Motorized switch fuse 44

OSM125GD3M230C 1SCA116674R1001 Motorized switch fuse 43

OSM125GD4N2M230C 1SCA118828R1001 Motorized switch fuse 43

OSM160GB3M230C 1SCA116670R1001 Motorized switch fuse 44

OSM160GB4N1M230C 1SCA118781R1001 Motorized switch fuse 44

OSM160GD3M230C 1SCA116673R1001 Motorized switch fuse 43

OSM160GD4N2M230C 1SCA118831R1001 Motorized switch fuse 43

OSM200B3M230C 1SCA104272R1001 Motorized switch fuse 44

OSM200B3N3M230C 1SCA104323R1001 Motorized switch fuse 44

OSM200B4N1M230C 1SCA118784R1001 Motorized switch fuse 44

OSM200D3M230C 1SCA104284R1001 Motorized switch fuse 43

OSM200D3N3M230C 1SCA104282R1001 Motorized switch fuse 43

OSM200D4N2M230C 1SCA118836R1001 Motorized switch fuse 43

OSM250B3M230C 1SCA104287R1001 Motorized switch fuse 44

OSM250B3N3M230C 1SCA104290R1001 Motorized switch fuse 44

OSM250B4N1M230C 1SCA118785R1001 Motorized switch fuse 44

OSM250D3M230C 1SCA104295R1001 Motorized switch fuse 43

OSM250D3N3M230C 1SCA104297R1001 Motorized switch fuse 43

OSM250D4N2M230C 1SCA118838R1001 Motorized switch fuse 43

OSM315B3M230C 1SCA104303R1001 Motorized switch fuse 44

OSM315B3N3M230C 1SCA104306R1001 Motorized switch fuse 44

OSM315B4N1M230C 1SCA118788R1001 Motorized switch fuse 44

OSM32GB3M230C 1SCA116662R1001 Motorized switch fuse 44

OSM32GB4N1M230C 1SCA118775R1001 Motorized switch fuse 44

OSM32GD3M230C 1SCA116664R1001 Motorized switch fuse 43

OSM32GD4N2M230C 1SCA118822R1001 Motorized switch fuse 43

OSM400B3M230C 1SCA104310R1001 Motorized switch fuse 44

OSM400B3N3M230C 1SCA104312R1001 Motorized switch fuse 44

OSM400B4N1M230C 1SCA118789R1001 Motorized switch fuse 44

OSM400D3M230C 1SCA104315R1001 Motorized switch fuse 43

OSM400D3N3M230C 1SCA104317R1001 Motorized switch fuse 43

OSM400D4N2M230C 1SCA118842R1001 Motorized switch fuse 43

OSM630B3M230C 1SCA104516R1001 Motorized switch fuse 44

OSM630B3N3M230C 1SCA104535R1001 Motorized switch fuse 44

OSM630B4N1M230C 1SCA118791R1001 Motorized switch fuse 44

OSM630D3M230C 1SCA104518R1001 Motorized switch fuse 43

OSM630D3N3M230C 1SCA104533R1001 Motorized switch fuse 43

OSM630D4N2M230C 1SCA118846R1001 Motorized switch fuse 43

Page 110: Switch fuses OS and OSM - ABB

110 Index | Switch fuses OS and OSM

Type Order number Description Page

OSM63GB3M230C 1SCA116657R1001 Motorized switch fuse 44

OSM63GB4N1M230C 1SCA118776R1001 Motorized switch fuse 44

OSM63GD3M230C 1SCA116660R1001 Motorized switch fuse 43

OSM63GD4N2M230C 1SCA118865R1001 Motorized switch fuse 43

OSM800B3M230C 1SCA104520R1001 Motorized switch fuse 44

OSM800B3N3M230C 1SCA104536R1001 Motorized switch fuse 44

OSM800B4N1M230C 1SCA118792R1001 Motorized switch fuse 44

OSM800D3M230C 1SCA104522R1001 Motorized switch fuse 43

OSM800D3N3M230C 1SCA104534R1001 Motorized switch fuse 43

OSM800D4N2M230C 1SCA118847R1001 Motorized switch fuse 43

OSP1250B 1SCA107950R1001 Fourth poles 57

OSP1250D 1SCA107946R1001 Fourth poles 57

OSP1250DA 1SCA112402R1001 Fourth poles 57

OSP1250N 1SCA107943R1001 Fourth poles 57

OSP160GB 1SCA114769R1001 Fourth poles 57

OSP160GD 1SCA114768R1001 Fourth poles 57

OSP160GN 1SCA114770R1001 Fourth poles 57

OSP200B 1SCA022735R9180 Fourth poles 57

OSP200D 1SCA022735R8960 Fourth poles 57

OSP200N 1SCA022735R8700 Fourth poles 57

OSP250B 1SCA022770R4030 Fourth poles 57

OSP250D 1SCA022735R9340 Fourth poles 57

OSP250N 1SCA022735R9260 Fourth poles 57

OSP400B 1SCA022770R3140 Fourth poles 57

OSP400D 1SCA022770R3220 Fourth poles 57

OSP400N 1SCA022770R3490 Fourth poles 57

OSP800B 1SCA100434R1001 Fourth poles 57

OSP800D 1SCA100433R1001 Fourth poles 57

OSP800N 1SCA100432R1001 Fourth poles 57

OSS1250G1L/3 1SCA107938R1001 Terminal shroud 60

OSS1250G1L/4 1SCA107940R1001 Terminal shroud 60

OSS1250G1S/3 1SCA107939R1001 Terminal shroud 60

OSS1250G1S/4 1SCA107941R1001 Terminal shroud 60

OSS160GG1L/3 1SCA114764R1001 Terminal shroud 60

OSS160GG1L/4 1SCA114765R1001 Terminal shroud 60

OSS160GG1S/3 1SCA114766R1001 Terminal shroud 60

OSS160GG1S/4 1SCA114767R1001 Terminal shroud 60

OSS160GG3LS 1SCA121570R1001 Three and four pole terminal

shroud

61

OSS160GG4LS 1SCA121571R1001 Three and four pole terminal

shroud

61

OSS200G1L/3 1SCA022731R8910 Terminal shroud 60

OSS200G1L/4 1SCA022731R9040 Terminal shroud 60

OSS200G1S/3 1SCA022732R0130 Terminal shroud 60

OSS200G1S/4 1SCA022732R0050 Terminal shroud 60

OSS250G1L 1SCA022727R5080 Terminal shroud 60

OSS250G1L/3 1SCA022731R9390 Terminal shroud 60

OSS250G1L/4 1SCA022731R9470 Terminal shroud 60

OSS250G1S 1SCA022727R4940 Terminal shroud 60

OSS250G1S/3 1SCA022731R9550 Terminal shroud 60

OSS250G1S/4 1SCA022731R9630 Terminal shroud 60

OSS250G1SH/1 1SCA103500R1001 Terminal shroud 60

OSS400G1L/3 1SCA022776R6650 Terminal shroud 60

OSS400G1L/4 1SCA022776R6730 Terminal shroud 60

OSS400G1S/3 1SCA022776R6900 Terminal shroud 60

OSS400G1S/4 1SCA022776R7030 Terminal shroud 60

OSS400G1SH/1 1SCA103503R1001 Terminal shroud 60

OSS400G3LS 1SCA100396R1001 Three and four pole terminal

shroud

61

OSS400G3SS 1SCA100390R1001 Three and four pole terminal

shroud

61

Type Order number Description Page

OSS400G4LSL 1SCA100398R1001 Three and four pole terminal

shroud

61

OSS400G4LSR 1SCA100400R1001 Three and four pole terminal

shroud

61

OSS400G4SSL 1SCA100392R1001 Three and four pole terminal

shroud

61

OSS400G4SSR 1SCA100394R1001 Three and four pole terminal

shroud

61

OSS800G1L/3 1SCA022776R7200 Terminal shroud 60

OSS800G1L/4 1SCA022776R7380 Terminal shroud 60

OSS800G1S/3 1SCA022776R7540 Terminal shroud 60

OSS800G1S/4 1SCA022776R7460 Terminal shroud 60

OSV1250DK 1SCA107797R1001 Direct mount handles 50

OSV200BK 1SCA022779R7530 Direct mount handles 50

OSV250DK 1SCA022763R3510 Direct mount handles 50

OSV400BK 1SCA022763R3930 Direct mount handles 50

OSV400DK 1SCA022763R4230 Direct mount handles 50

OSV800DK 1SCA107794R1001 Direct mount handles 50

OSVY1250DK 1SCA108702R1001 Direct mount handles 50

OSVY200BK 1SCA022779R7700 Direct mount handles 50

OSVY250DK 1SCA022778R6500 Direct mount handles 50

OSVY400BK 1SCA022779R5830 Direct mount handles 50

OSVY400DK 1SCA022779R5590 Direct mount handles 50

OSVY800DK 1SCA108703R1001 Direct mount handles 50

OSZ1 1SCA022481R3710 Neutral links 58

OSZ2 1SCA022481R3800 Neutral links 58

OSZ4 1SCA022530R0200 Electronic fuse monitor 67

OSZT1A 1SCA106532R1001 Mechanism interlock kits &

Electrical interlocks

69

OSZT1L 1SCA106538R1001 Mechanism interlock kits &

Electrical interlocks

69

OSZT2A 1SCA106534R1001 Mechanism interlock kits &

Electrical interlocks

69

OSZT2L 1SCA106539R1001 Mechanism interlock kits &

Electrical interlocks

69

OSZT3A 1SCA106535R1001 Mechanism interlock kits &

Electrical interlocks

69

OSZT3L 1SCA106540R1001 Mechanism interlock kits &

Electrical interlocks

69

OSZT4A 1SCA106536R1001 Mechanism interlock kits &

Electrical interlocks

69

OSZT4L 1SCA106541R1001 Mechanism interlock kits &

Electrical interlocks

69

OSZX3 1SCA101224R1001 Blown fuse indicators (DPMM) 68

OSZX4 1SCA101225R1001 Blown fuse indicators (DPMM) 68

OTS1600G1L 1SCA106134R1001 Terminal shroud 60

OTS1600G1S 1SCA102667R1001 Terminal shroud 60

OTS250G1L 1SCA022715R5340 Terminal shroud 60

OTS250G1S 1SCA022715R5260 Terminal shroud 60

OTS800G1L 1SCA022776R7710 Terminal shroud 60

OTS800G1S 1SCA022776R8010 Terminal shroud 60

OTVS1 1SCA111413R1001 Handle and spare fuse storage clip 59

OTVS2 1SCA111414R1001 Handle and spare fuse storage clip 59

OTZT1A 1SCA106522R1001 Mechanism interlock kits &

Electrical interlocks

69

OTZT1L 1SCA106527R1001 Mechanism interlock kits &

Electrical interlocks

69

OTZW10 1SCA022431R5280 Conversion kits 65

OTZW25 1SCA022778R6920 Conversion kits 65

OTZW26 1SCA022778R7060 Conversion kits 65

OWC6DSH1 1SCA105251R1001 Conversion kits 65

Page 111: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Index 111

Type Order number Description Page

OWC6DSH2 1SCA105252R1001 Conversion kits 65

OWM6DS1 1SCA105253R1001 Conversion kits 65

OWM6DS2 1SCA105254R1001 Conversion kits 65

OWP6DS1 1SCA105255R1001 Conversion kits 65

OWP6DS2 1SCA105256R1001 Conversion kits 65

OXN1250S 1SCA104163R1001 Neutral links 58

OXN250 1SCA022752R9950 Neutral links 58

OXN250 1SCA022752R9950 Neutral links 58

OXN400 1SCA022770R3060 Neutral links 58

OXN800S 1SCA022831R4880 Neutral links 58

OXP12X2503) 1SCA022325R6980 Extended shafts 52

OXP12X280 1SCA022137R5140 Extended shafts 52

OXP12X2802) 1SCA022137R5140 Extended shafts 53

OXP12X280-451) 1SCA022382R0800 Extended shafts 53

OXP12X325 1SCA022042R5810 Extended shafts 52

OXP12X325 1SCA022042R5810 Extended shafts 53

OXP12X325-451) 1SCA022304R4450 Extended shafts 53

OXP12X395 1SCA022042R5990 Extended shafts 52

OXP12X395 1SCA022042R5990 Extended shafts 53

OXP12X3952) 1SCA022042R5990 Extended shafts 53

OXP12X465 1SCA022042R6020 Extended shafts 52

OXP12X465 1SCA022042R6020 Extended shafts 53

OXP12X465 1SCA022042R6020 Extended shafts 53

OXP12X535 1SCA022042R6110 Extended shafts 52

OXP12X535 1SCA022042R6110 Extended shafts 53

OXP12X535 1SCA022042R6110 Extended shafts 53

OXP6X130 1SCA022057R0570 Extended shafts 51

OXP6X130 1SCA022057R0570 Extended shafts 52

OXP6X150-451) 1SCA022294R4400 Extended shafts 51

OXP6X150-451) 1SCA022294R4400 Extended shafts 51

OXP6X1505) 1SCA022295R5600 Extended shafts 51

OXP6X1505) 1SCA022295R5600 Extended shafts 51

OXP6X161 1SCA022067R1760 Extended shafts 52

OXP6X161 1SCA022067R1760 Extended shafts 52

OXP6X1613) 1SCA022067R1760 Extended shafts 51

OXP6X1613) 1SCA022067R1760 Extended shafts 52

OXP6X170 1SCA108224R1001 Extended shafts 51

OXP6X170 1SCA108224R1001 Extended shafts 51

OXP6X170-451) 1SCA108227R1001 Extended shafts 51

OXP6X170-451) 1SCA108227R1001 Extended shafts 51

OXP6X210 1SCA022295R6080 Extended shafts 51

OXP6X210 1SCA022295R6080 Extended shafts 52

OXP6X2103) 1SCA022295R6080 Extended shafts 52

OXP6X2103) 1SCA022295R6080 Extended shafts 52

OXP6X210-451) 1SCA022294R4230 Extended shafts 51

OXP6X210-451) 1SCA022294R4230 Extended shafts 52

OXP6X265 1SCA108225R1001 Extended shafts 51

OXP6X265 1SCA108225R1001 Extended shafts 51

OXP6X265-451) 1SCA108228R1001 Extended shafts 51

OXP6X265-451) 1SCA108228R1001 Extended shafts 51

OXP6X290 1SCA022042R6370 Extended shafts 51

OXP6X290 1SCA022042R6370 Extended shafts 52

OXP6X290 1SCA022042R6370 Extended shafts 52

OXP6X290 1SCA022042R6370 Extended shafts 52

OXP6X290-451) 1SCA022304R4290 Extended shafts 51

OXP6X290-451) 1SCA022304R4290 Extended shafts 52

OXP6X360 1SCA022042R6530 Extended shafts 51

OXP6X360 1SCA022042R6530 Extended shafts 52

OXP6X360-451) 1SCA022341R4640 Extended shafts 51

OXP6X360-451) 1SCA022341R4640 Extended shafts 52

OXP6X400 1SCA108226R1001 Extended shafts 51

Type Order number Description Page

OXP6X400 1SCA108226R1001 Extended shafts 51

OXP6X400-451) 1SCA108229R1001 Extended shafts 51

OXP6X400-451) 1SCA108229R1001 Extended shafts 51

OXP6X430 1SCA022056R6030 Extended shafts 51

OXP6X430 1SCA022056R6030 Extended shafts 52

OXP6X63 1SCA111010R1001 Extended shafts 51

OXP6X63 1SCA111010R1001 Extended shafts 52

OXP6X90 1SCA022064R1180 Extended shafts 51

OXP6X90 1SCA022064R1180 Extended shafts 52

OZXB17 1SCA022859R3230 Terminal clamp sets 62

OZXB1L 1SCA022169R2030 Terminal clamp sets 62

OZXB1L 1SCA022169R2030 Terminal clamp sets 62

OZXB1L 1SCA022169R2030 Terminal clamp sets 62

OZXB2 1SCA022119R7610 Terminal clamp sets 62

OZXB2K 1SCA022264R0010 Single pole terminal shroud 61

OZXB2K/1 1SCA022644R6700 Single pole terminal shroud 61

OZXB2L 1SCA022158R7750 Terminal clamp sets 62

OZXB2L 1SCA022158R7750 Terminal clamp sets 62

OZXB2L 1SCA022158R7750 Terminal clamp sets 63

OZXB3 1SCA022136R8100 Terminal clamp sets 62

OZXB3 1SCA022136R8100 Terminal clamp sets 63

OZXB3 1SCA022136R8100 Terminal clamp sets 63

OZXB3 1SCA022136R8100 Terminal clamp sets 64

OZXB3K 1SCA022264R0440 Single pole terminal shroud 61

OZXB3K/1 1SCA022644R6880 Single pole terminal shroud 61

OZXB4 1SCA022137R4760 Terminal clamp sets 62

OZXB4 1SCA022137R4760 Terminal clamp sets 63

OZXB4 1SCA022137R4760 Terminal clamp sets 63

OZXB4 1SCA022137R4760 Terminal clamp sets 64

OZXB4K 1SCA022199R2850 Single pole terminal shroud 61

OZXB4K/1 1SCA022644R6960 Single pole terminal shroud 61

OZXB5 1SCA022137R2470 Terminal clamp sets 62

OZXB5 1SCA022137R2470 Terminal clamp sets 63

OZXB5 1SCA022137R2470 Terminal clamp sets 63

OZXB5 1SCA022137R2470 Terminal clamp sets 64

OZXB5K 1SCA022283R8040 Single pole terminal shroud 61

OZXB5K/1 1SCA022644R7000 Single pole terminal shroud 61

OZXB6 1SCA022137R4920 Terminal clamp sets 63

OZXB6 1SCA022137R4920 Terminal clamp sets 63

OZXB6 1SCA022137R4920 Terminal clamp sets 64

OZXB7 1SCA022185R0040 Terminal clamp sets 63

OZXB7L 1SCA022185R7130 Terminal clamp sets 62

OZXB7L 1SCA022185R7130 Terminal clamp sets 63

OZXB7L 1SCA022185R7130 Terminal clamp sets 64

OZXB8 1SCA022744R1510 Terminal clamp sets 62

OZXB8 1SCA022744R1510 Terminal clamp sets 62

OZXB8 1SCA022744R1510 Terminal clamp sets 62

OZXB8 1SCA022744R1510 Terminal clamp sets 63

OZXB8 1SCA022744R1510 Terminal clamp sets 63

OZXB8 1SCA022744R1510 Terminal clamp sets 64

OZXB9 1SCA022750R3210 Terminal clamp sets 62

OZXB9 1SCA022750R3210 Terminal clamp sets 62

OZXB9 1SCA022750R3210 Terminal clamp sets 63

OZXB9 1SCA022750R3210 Terminal clamp sets 63

OZXB9 1SCA022750R3210 Terminal clamp sets 64

OZXP120 1SCA115540R1001 Terminal clamp sets 64

OZXP150 1SCA115541R1001 Terminal clamp sets 64

OZXP240 1SCA115542R1001 Terminal clamp sets 64

OZXP240 1SCA115542R1001 Terminal clamp sets 64

OZXP240 1SCA115542R1001 Terminal clamp sets 64

OZXP2X240 1SCA115544R1001 Terminal clamp sets 64

Page 112: Switch fuses OS and OSM - ABB

112 Index | Switch fuses OS and OSM

Type Order number Description Page

OZXP2X240 1SCA115544R1001 Terminal clamp sets 64

OZXP300 1SCA115543R1001 Terminal clamp sets 64

OZXP95 1SCA115539R1001 Terminal clamp sets 64

OZXP95 1SCA115539R1001 Terminal clamp sets 64

OZXR185 1SCA115531R1001 Terminal clamp sets 64

OZXR185 1SCA115531R1001 Terminal clamp sets 64

OZXR240 1SCA115532R1001 Terminal clamp sets 64

OZXR2X185 1SCA115534R1001 Terminal clamp sets 64

OZXR2X185 1SCA115534R1001 Terminal clamp sets 64

OZXR2X185 1SCA115534R1001 Terminal clamp sets 64

OZXR2X300 1SCA115535R1001 Terminal clamp sets 64

OZXR300 1SCA115533R1001 Terminal clamp sets 64

OZXR70 1SCA115529R1001 Terminal clamp sets 64

OZXR95 1SCA115530R1001 Terminal clamp sets 64

OZXR95 1SCA115530R1001 Terminal clamp sets 64

OZXT1 1SCA022469R6310 Terminal clamp sets 62

PB200 high 1SDA054972R1 Phase barries 59

PB200 high 1SDA054973R1 Phase barries 59

PDAL2/110AC50Hz 1SCA106543R1001 Coils 70

PDAL2/110AC60Hz 1SCA107100R1001 Coils 70

PDAL2/110DC 1SCA107105R1001 Coils 70

PDAL2/120AC60Hz 1SCA111353R1001 Coils 70

PDAL2/125DC 1SCA111338R1001 Coils 70

PDAL2/208AC60Hz 1SCA107101R1001 Coils 70

PDAL2/220DC 1SCA112503R1001 Coils 70

PDAL2/230AC50Hz 1SCA107102R1001 Coils 70

PDAL2/240AC60Hz 1SCA111356R1001 Coils 70

PDAL2/24AC60Hz 1SCA111350R1001 Coils 70

PDAL2/24DC 1SCA106542R1001 Coils 70

PDAL2/48DC 1SCA107103R1001 Coils 70

PDAL2/60DC 1SCA107104R1001 Coils 70

Page 113: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Index 113

For Your Notes

Page 114: Switch fuses OS and OSM - ABB

114 Index | Switch fuses OS and OSM

For Your Notes

Page 115: Switch fuses OS and OSM - ABB

Switch fuses OS and OSM | Index 115

For Your Notes

Page 116: Switch fuses OS and OSM - ABB

Contact us

© C

opyr

ight

AB

B.

Cat

alog

ue O

S1G

B 1

5-08

, 1S

CC

3110

13C

0201

Note: We reserve the right to make technical changes ormodify the contents of this document without prior notice.With regard to purchase orders, the agreed particulars shallprevail. ABB AG does not accept any responsibility whatsoeverfor potential errors or possible lack of information in this document.We reserve all rights in this document and in the subject matterand illustrations contained therein. Any reproduction, disclosureto third parties or utilization of its contents – in whole or in parts –is forbidden without prior written consent of ABB AG.

Copyright © 2014 ABBAll rights reserved

ABB Oy Breakers and SwitchesP.O. Box 622 FI-65101 Vaasa, Finland Phone: +358 10 22 11 Fax: +358 10 22 45708 E-Mail: [email protected] http://new.abb.com/low-voltage/

You can find the address of your local sales organizationon the ABB homepage: