Top Banner

of 17

Surge Test Report Jan 2016

Jul 07, 2018

Download

Documents

Vijay Mohan
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • 8/18/2019 Surge Test Report Jan 2016

    1/17

     

    Surge Test Report

    Prepared for

    ONGC AssamShivsagar

    Visit Nov-Dec 2015Jan 2016

    Compressor Controls Corporation’sProject CCC #13796

  • 8/18/2019 Surge Test Report Jan 2016

    2/17

     

    Technical Support

    For current CCC Customers, please have your CCC project number and call:T: +1-800-387-4652  (US and Canada, Des Moines, Iowa); T: +1-515-251-2736  (Americas and Asia-Pacific, Des Moines, Iowa);T: +31-20-407-0000  (Europe and Africa, Amsterdam);T: +971-2-446 9671  (Middle East, Abu Dhabi);T: +7-495-913-9764  (Russia and CIS, Moscow).

    Request Field Service:

    •  [email protected]  - North & South America, Asia and Pacific

    •  [email protected]  - Europe and Africa

    •  [email protected]  - Middle East

    •  [email protected]  - Russia and CIS

    Worldwide Offices 

    CCC Headquarters - Des Moines4725 121st StreetDes Moines, Iowa 50323-2316U.S.A.T: +1-515-270-0857F: +1-515-270-1331

    CCC - Australia55 Moss Street,East Fremantle, Perth,Western Australia, 6158T: +61-8-94382321M: +61-488088812

    CCC - BrazilRua Victor Civita, 66Bloco 2, sala 214Rio Office Park,

    Barra da Tijuca, 22275-044Rio de Janeiro, RJBrazilT: +55-21-3535-9293F: +55-21-3535-9294M: +55-21-9131-2758

    CCC - ChinaRm 1001, Sunjoy Mansion,6 Ritan RoadChaoyang Dist.Beijing, 100020Peoples Republic of ChinaT: +86-10-65-07-0590

    F: +86-10-65-07-0530

    CCC - ItalyCompressor ControlsCorporation Srl,V. le Brianza 20,20092, Cinisello Balsamo,Milan, ItalyT: +39-02-618-0231F: +39-02-618-02330

    CCC - NetherlandsWeerenweg 10,1161 AH Zwanenburg,The NetherlandsT: +31-20-407-0000F: +31-20-407-0099

    Mailing Address:Compressor Controls

    Corporation BV,PO Box 134,1160 AC Zwanenburg,The Netherlands

    CCC - RussiaRoper LLCMoscow 115419,Shabolovka street, 34,bldg. 2, office 14T: +7-495-913-9764T: +7-495-617-12-93/94/95F: +7-495-913-9765

    CCC - Saudi ArabiaT: +966-3-833-7973F: +966-3-833-0508M: +966-55-512-9014

    CCC - Singapore10 Eunos Road 8, #12-06Singapore Post CentreSingapore, 408600T: +65-6408-6220F: +65-6293-3307

    CCC - Houston8824 FallbrookHouston, TX 77064-9912U.S.A.T: +1-281-583-7799F: +1-281-583-8788

    CCC - India35, 1st Floor, Dheeraj Heritage,S.V. RoadSantacruz (West), Mumbai,Maharashtra, 400054,IndiaT: +91-22-66994803F: +91-22-66994803M: +91-98203-33819

    CCC – U.A.E.

    Villa 8/1, Ninth (9th) StreetAl Karamah, 109174,Abu Dhabi, U.A.E.T: +971-2-446-9671F: +971-2-446-9772

    CCC - UKPinewood, Chineham Business ParkCrockford Lane, ChinehamBasingstokeHampshire RG24 8ALUnited KingdomT: +44-134-470-1807F: +44-125-669-8275

  • 8/18/2019 Surge Test Report Jan 2016

    3/17

     Compressor Controls Field Service Report

    Project 13874  

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 3 of 17

  • 8/18/2019 Surge Test Report Jan 2016

    4/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 4 of 17

  • 8/18/2019 Surge Test Report Jan 2016

    5/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 5 of 17

    GGS9-LP Train B Surge test : IGV=15%

  • 8/18/2019 Surge Test Report Jan 2016

    6/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 6 of 17

    GGS9-LP Train B Surge test : IGV=35%

  • 8/18/2019 Surge Test Report Jan 2016

    7/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 7 of 17

    GGS9-LP Train B Surge test : IGV=50%

  • 8/18/2019 Surge Test Report Jan 2016

    8/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 8 of 17

  • 8/18/2019 Surge Test Report Jan 2016

    9/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 9 of 17

  • 8/18/2019 Surge Test Report Jan 2016

    10/17

  • 8/18/2019 Surge Test Report Jan 2016

    11/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 11 of 17

    GGS9-LP Train C Surge test : IGV=35%

  • 8/18/2019 Surge Test Report Jan 2016

    12/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 12 of 17

    GGS9-LP Train C Surge test : IGV=50%

  • 8/18/2019 Surge Test Report Jan 2016

    13/17

  • 8/18/2019 Surge Test Report Jan 2016

    14/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 14 of 17

  • 8/18/2019 Surge Test Report Jan 2016

    15/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 15 of 17

    Train C Surge test, IGV=3.5%

  • 8/18/2019 Surge Test Report Jan 2016

    16/17

     Compressor Controls Field Service Report

    Project 13796

    Last printed 10-Feb-16 Dec09 Rev 5.0 Page 16 of 17

    Train C surge test, IGV=15%:

  • 8/18/2019 Surge Test Report Jan 2016

    17/17

     Compressor Controls Field Service Report

    Project 13796

    Train C surge test, IGV=25%: