DISTRIBUTED BY 133 122 | cabac.com.au Surge Protection Devices 2020
191075 - Auswahlhilfe TBS MCF CompactV50 V20 SG_NEU.indd 1 26.11.19 11:15
DISTRIBUTED BY
133 122 | cabac.com.au
Surge Protection Devices 2020
191075 - Auswahlhilfe TBS MCF CompactV50 V20 SG_NEU.indd 1 26.11.19 11:15
MCF
V50
V20
191075 - Auswahlhilfe TBS MCF CompactV50 V20 SG_NEU.indd 2 26.11.19 11:15
Type classes of surge protective devices
• Type 1 + 2 SPD: Imp = 25 kA per pole and up to 100 kA in total• Compact design, only 105 mm wide• Protection level: < 1.5 kV• Safe up to mains following current of 50 kA•QualityaccordingtoIEC61643-11certifiedbyanexternal
testing institute•Systemprotectionupto315Ausablewithoutseparatefusing•Remotesignaling,potential-freechangeover(RS)•OperatinginstructionsalwaysavailableonlineviaQRcode
• Type 1 + 2 SPD: Imp = 12.5 kA per pole and up to 50 kA in total• Protection level: < 1.5 kV•QualityaccordingtoIEC61643-11certifiedbyanexternal
testing institute•Systemprotectionupto160Ausablewithoutseparatefusing•Lockingfunctionwithvibrationprotection•Optionalremotesignaling,potential-freechangeover(RS)• Variants in one to four-pole versions•OperatinginstructionsalwaysavailableonlineviaQRcode
•Type2SPD:In=20kA(L-N)andupto40kAperpole• Protection level: < 1.5 kV•ExceedstheincreasedrequirementsaccordingtoIEC60364-4-44•QualityaccordingtoIEC61643-11certifiedbyanexternaltesting
institute•Lockingfunctionwithvibrationprotection•Systemprotectionupto160Ausablewithoutseparatefusing•Optionalremotesignaling,potential-freechangeover(RS)• Variants in one to four-pole versions•OperatinginstructionsalwaysavailableonlineviaQRcode
2
Industry Office, commercialand residentialbuildings
Office, commercialand residentialbuildings
Main and subdis-tributor board
Office, commercialand residentialbuildings
191075 - Auswahlhilfe TBS MCF CompactV50 V20 SG_NEU.indd 3 26.11.19 11:15
Type 1 + 2 combination arrestorUsedatthefeedpointofthebuilding.
Type 1 + 2 combination arrestor.Usedatthefeedpointofthebuilding.
Type 2 surge protectionTheyareusedinthemaindistributorandinsub-distributors/switchingcabinets.
MCF CompactLightning protection class 1-4Fulfillstherequirementto100kA(10/350)perSPD
V50Lightning protection class 3-4Fulfillstherequirementto50kA(10/350)perSPD
V20Fulfillstherequirementto40kA(8/20)perpole
3
Type 3: For added protection to sensitive equipment
Type 2: For protection against switchingoperations and distant lightning strikes
Type 1: For protection against nearbylightning strikes
OBO BETTERMANN Surge Protection Device Selection Chart
191075 - Auswahlhilfe TBS MCF CompactV50 V20 SG_NEU.indd 4 26.11.19 11:15
DISTRIBUTED BY
133 122 | cabac.com.au
Part No. Description Type 1 Type 2 Single PhaseThree Phase
Remote Signal NPE*
MCF100-3-NPE-FS MCFTYPE1+23P+NPE+SIGNAL √ √ √ √ √
MCF75-3-FS MCFTYPE1+23P+NPE+SIGNAL √ √ √ √
V50-1-280 V50 TYPE 1+2 1P √ √ √
V50-1-FS-280 V50TYPE1+21P+SIGNAL √ √ √ √
V50-1-NPE-280 V50TYPE1+21P+NPE √ √ √ √
V50-1-NPE-FS-280 V50TYPE1+21P+NPE+SIGNAL √ √ √ √ √
V50-3-280 V50 TYPE 1+2 3P √ √ √
V50-3-FS-280 V50TYPE1+23P+SIGNAL √ √ √ √
V50-3-NPE-280 V50TYPE1+23P+NPE √ √ √ √
V50-3-NPE-FS-280 V50TYPE1+23P+NPE+SIGNAL √ √ √ √ √
V20-1-280 V20 TYPE 2 1P √ √
V20-1-FS-280 V20TYPE21P+SIGNAL √ √ √
V20-1-NPE-280 V20TYPE21P+NPE √ √ √
V20-1-NPE-FS-280 V20TYPE21P+NPE+SIGNAL √ √ √ √
V20-3-280 V20 TYPE 2 3P √ √
V20-3-FS-280 V20TYPE23P+SIGNAL √ √ √
V20-3-NPE-280 V20TYPE23P+NPE √ √ √
V20-3-NPE-FS-280 V20TYPE23P+NPE+SIGNAL √ √ √ √
*Neutral-PotentialEarthProtection
In support of our policy of continuous product improvement we reserve the right to change materials and specifications without notice. Drawings, where shown, may not be to scale. Dimensions are metric and size maybe approximate. Where possible data sheets including MSDS are made available on our website and APPs. All products should be installed and used in accordance to manufacturer’s instruction provided. Warning: products may be subject of registered designs and patents. Refer to our website or APPs for terms and conditions on warranty. Every effort has been made to ensure accuracy of content. However no liability will be met by CABAC or its suppliers for any errors or omissions. Product data and information is no binding. All brands and logos are registered trademarks and are subject to copyright laws. No part of this catalogue can be reproduced without the consent of CABAC. The ‘One Call, One Day, One Delivery’ does not cover the following items: CABCHEM, Cast Resin Kits, Custom Manufacturing & Kitting, Cabinets, Ladders, Pits & Pillars, CABTRAY and Branch Stock Orders.
PartNo.OBOSCAT
Type 3: For added protection to sensitive equipment
Type 2: For protection against switchingoperations and distant lightning strikes
Type 1: For protection against nearbylightning strikes
OBO BETTERMANN Surge Protection Device Selection Chart
191075 - Auswahlhilfe TBS MCF CompactV50 V20 SG_NEU.indd 4 26.11.19 11:15
Type 3: For added protection to sensitive equipment
Type 2: For protection against switchingoperations and distant lightning strikes
Type 1: For protection against nearbylightning strikes
OBO BETTERMANN Surge Protection Device Selection Chart
191075 - Auswahlhilfe TBS MCF CompactV50 V20 SG_NEU.indd 4 26.11.19 11:15
Supportedwithanindustry leading5 year warranty
FullycertifiedforglobalandAustralianrequirements
Type 3: For added protection to sensitive equipment
Type 2: For protection against switchingoperations and distant lightning strikes
Type 1: For protection against nearbylightning strikes
OBO BETTERMANN Surge Protection Device Selection Chart
191075 - Auswahlhilfe TBS MCF CompactV50 V20 SG_NEU.indd 4 26.11.19 11:15