Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AJ009NBNDCH/AA www.SamsungHVAC.com 888-699-6067 Page 1 of 2 Samsung FJM Series, Wind-Free™ Mini 4-Way Cassette © 2019 Samsung HVAC SHA-FJM-03262019 Cooling (Btu/h) 8,900 Heating (Btu/h) 9,900 1 / 208-230 / 60 0.51 Turbo (1) Type BLDC (1) FLA / Output 0.17A / 24 W Airflow CFM L/M/H 244 / 290 / 318 R410A Electronic Expansion Valve (at outdoor unit) Liquid (flare) Inches 1/4 Suction (flare) Inches 3/8 Drain Inches OD 1 1/4, ID 1 W X H X D Inches 22 5/8 X 10 X 22 5/8 Weight 25.40 Sound Level L / H dB(A) 24 / 33 Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. Piping Connections Unit Dimensions Fan Type Motor Refrigerant Type Control Method Specifications Performance Nominal Capacity Power Voltage (ø/V/Hz) Nominal Running Current (A) lbs. • Electro-static, washable, pleated filters as standard (included with fascia panel) • Built in condensate pump with maximum 29" lift from the bottom of the unit, check valve, and float switch that disables indoor unit during overflow detection. • Knock-out for outside air capability (with booster fan connection) • Fascia panel shall have LED indicator lights, IR receiver, and 4 motorized louvers with independent control. • High-voltage terminal block temperature sensor to disable unit in the event overheating of power connection. • The indoor unit shall be powered by the outdoor unit Construction Galvanized steel frame with HIPS chassis and fascia panel certified to UL94 V0. Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Indoor Fan Indoor fan is a single turbo type Three fan speed settings and auto setting Controls Control signal shall be a DDC type signal Interconnect control wire between outdoor and indoor shall be 16AWG X 2 shielded The system shall integrate with the Samsung Controls Solution. Compatibility Will only operate with Samsung outdoor unit model numbers: AJ020JCJ2CH/AA, AJ020MCS3CH/AA, AJ024JCJ3CH/AA, AJ024MCS4CH/AA, AJ030MCS4CH/AA, AJ036JCJ5CH/AA, MIM-B14 MCR-SMD AR-EH03U MWR-WH00U 25' - ILS2506 50' - ILS5006 ETL (UL 1995) Safety Certifications Line sets - insulated and flared, interconnect cables included Accessories External Contact Control Motion Occupancy Sensor Wireless Remote Controller Standard Wired Controller • Wind-Free™ function will close the supply air outlet louver while in cooling mode to gently disperse cool air into the space without blowing directly onto occupants. The Wind-Free™ feature is optional and can be enabled using central or local control options (MWR-WE13U, AR-EH03U only). • The Wind-Free™ 4-way cassette can be configured for 2-stage operation, cooling the space with the louver open (fixed or swing) until the room temperature nears set temperature. Once room temperature is near set temperature, Wind-Free™ operation will start automatically, closing the louver and using the face of the fascia panel to gently cool the space with still air*. * The Wind-Free TM unit delivers an air current that is under 0.15 m/s while in Wind Free mode. Air velocity that is below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers). 24 3/8 X 24 3/8 X 2 1/4 lbs. Weight 6 Fascia Panel 1 (purchased separately) L X W X H (Inches) 24 3/8 X 24 3/8 X 2 3/16 PC4SUFMUN (Wind-Free™) PC4SUSMUN (Standard) 1 PC4SUFMUN fascia panel must be installed to use the Wind-Free™ functions. MWR-WE13U wired controller or AR-EH03U wireless remote control must be used to enable Wind-Free™ functions. The Wind-Free™ panel (PC4SUFMUN) has an integral humidity sensor that will open the louvers for standard cool mode when space conditions could potentially cause condensation formation on the panel surface. • MWR-WE13U Wired Controller W/Scheduling & Wind-Free™ PC4SUFMUN PC4SUSMUN Wind Free™ Fascia Panel Standard Fascia Panel