PT-3 CEILING FINISH WALL FINISH BASE FINISH FLOOR FINISH DENOTES EXTENT OF A SPECIFIC WALL FINISH KEYED NOTE TAG RE: KEYED NOTES LEGEND ON SAME SHEET 01 I-6.XX XX I-6.XX XX XX XX XX ELEVATION TAGS I-2.XX XX ENLARGED PLAN TAG SECTION TAG XX/I-7.XX 1 REVISION TAG INTERIORS SHEET INDEX REVISION # SHEET # DRAWING TITLE I-0.00 COVER SHEET I-0.01 FINISH SCHEDULE I-0.02 FINISH SCHEDULE I-0.03 DECORATIVE LIGHTING SCHEDULE I-1.00A FIRST FLOOR FINISH PLAN, AREA "A" I-1.00B FIRST FLOOR FINISH PLAN, AREA "B" I-1.00C FIRST FLOOR FINISH PLAN, AREA "C" I-1.00D FIRST FLOOR FINISH PLAN, AREA "D" I-1.00E FIRST FLOOR FINISH PLAN, AREA "E" I-2.00 ENLARGED UNIT PLANS I-3.00 ENLARGED FLOORING LAYOUT I-4.00A WALL PROTECTION PLANS, AREA "A" I-4.00B WALL PROTECTION PLANS, AREA "B" I-4.00C WALL PROTECTION PLANS, AREA "C" I-4.00D WALL PROTECTION PLANS, AREA "D" I-4.00E WALL PROTECTION PLANS, AREA "E" I-6.00 INTERIOR ELEVATIONS I-6.01 INTERIOR ELEVATIONS I-6.02 INTERIOR ELEVATIONS I-7.00 DETAILS XX-X XX-X XX-X XX-X XX-X/XX-X X, X, X COUNTERTOP FINISH/CABINET FINISH KEYED NOTES TYPICAL ROOM FINISHES, U.N.O. SYMBOLS LEGEND AFF CL CLG CLR DIA DIM DWG EA ELEV EQ FIXT FLR FO GYP HDWD INT MAX MIN MTL NIC NTS OC OH PLYD RCP SCHED SIM TYP UNO VIF ABOVE FINISHED FLOOR CENTERLINE CEILING CLEAR DIAMETER DIMENSION DRAWING EACH ELEVATION EQUAL FIXTURE FLOOR FACE OF GYPSUM WALL BOARD HARDWOOD INTERIOR MAXIMUM MINIMUM METAL NOT IN CONTRACT NOT TO SCALE ON CENTER OPPOSITE HAND PLYWOOD REFLECTED CEILING PLAN SCHEDULED SIMILAR TYP UNLESS NOTED OTHERWISE VERIFY IN FIELD NOTE: 1. ALL ABBREVIATIONS LISTED ABOVE MAY NOT BE USED ON THIS PROJECT. 2. ABBREVIATIONS FOR FINISHES CAN BE FOUND ON THE FINISH SCHEDULE. ABBREVIATIONS GENERAL NOTES G1. GENERAL CONTRACTOR TO COORDINATE ALL BLOCKING; LAYOUT DIMENSIONS AND PENETRATIONS REQUIRED. G2. ALL CONSTRUCTION MATERIALS, FIXTURES, FINISHES, ETC. ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. G3. CONTRACTOR TO PROVIDE PRODUCT CERTIFICATES & SHOP DRAWINGS OF ALL MILLWORK/CASEWORK AND SAMPLES OF ALL FINISHES AND ARCHITECTURAL SPECIALTY ITEMS FOR APPROVAL. G4. PROVIDE WOOD BLOCKING BEHIND ALL WALL MOUNTED ITEMS. G5. THESE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. IN THE EVENT OF AN INCORRECT OR AN OMISSION OF NECESSARY DIMENSIONS CONTRACTOR SHALL NOTIFY INTERIOR DESIGNER OR OWNER'S REPRESENTATIVE. G6. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS PRIOR TO CONSTRUCTION AND NOTIFY INTERIOR DESIGNER OF ANY DISCREPANCIES THAT COULD EFFECT THE DESIGN AND FINISH OUT OF THE PROJECT. G7. DO NOT SUSPEND ANY ITEMS FROM METAL ROOF DECKS, HORIZONTAL BRIDGING, X-BRACING, PIPES OR CONDUITS, OR ANY OTHER WORK BY OTHER TRADES. G8. EACH CONTRACTOR SHALL COMPLY WITH ALL PROVISIONS OF ALL APPLICABLE LAWS AND ORDERS OF PUBLIC OFFICIALS WITH JURISDICTION FOR SAFETY OF PERSONS AND PROPERTY. G9. VERIFY WITH MANUFACTURER OR SUPPLIER THE SIZE, LOCATION, AND CHARACTERISTICS OF ALL WORK AND EQUIPMENT THAT IS TO BE FURNISHED BY OWNER OR OTHER CONTRACTORS PRIOR TO ANY CONSTRUCTION PERTAINING TO THE SAME IS BEGUN. G10. WHERE MULTIPLE FINISHES ARE LISTED IN THE SAME ROOM, OR ON THE SAME WALL, REFER TO INTERIOR FINISH PLANS AND/OR INTERIOR ELEVATIONS FOR APPLICATION. G11. INSTALL WP-2 AT ALL EXPOSED UNDERCOUNTER SPACES IN FOOD SERVICE AREAS. G12. ELEC. SWITCH/OUTLET & COVER PLATE COLOR TO BE WHITE, U.N.O. G13. REFER TO INTERIORS COVER SHEET FOR ALL BACK OF HOUSE FINISHES AND TYPICAL FINISHES. G14. ALL KEYED NOTES ON BACK OF HOUSE AND TYPICAL FINISH TAGS REFERENCE THE KEYED NOTES ON THE FINISH FLOOR PLANS. G15. ALL KEYED NOTES MAY NOT BE USED ON EVERY SHEET. G16. INTERIOR DESIGNER TO BE NOTIFIED OF ALL CEILING HEIGHT CHANGES OR CONFLICTS THAT DO NOT COMPLY WITH THESE DRAWINGS. G17. REFER TO ARCH. / M.E.P. DRAWINGS FOR ALL PLUMBING EQUIPMENT, U.N.O. G18. REFER TO FOOD SERVICE DRAWINGS FOR ALL FOOD SERVICE EQUIPMENT, U.N.O. PAINT P1. CONTRACTOR SHALL PROVIDE 6'-0"X6'-0" MOCK UPS OF EACH PAINT COLOR AND CONTACT INTERIOR DESIGNER TO SCHEDULE SITE VISIT TO CONFIRM EACH PRIOR TO APPLICATION. P2. ALL KITCHEN PREP WALL AND CEILING AREAS SHALL BE PAINTED WITH EPOXY PAINT. P3. MECHANICAL GRILLES AND WALL DIFFUSERS, ELECTRICAL PANELS, ACCESS PANELS, ETC. WHICH ARE EXPOSED IN FINISHED SPACES SHALL BE PAINTED, IN PROPER PAINT FORMULATION, TO MATCH THE SURFACE ON WHICH THEY OCCUR. P4. TYPICAL OVERALL PAINT FINISHES (U.N.O.): WALLS: EGG SHELL / SATIN TRIM: SEMI-GLOSS CEILING: FLAT CMU: SEMI-GLOSS DOORS & FRAME: SEMI-GLOSS P5. ALL FOOD SERVICE AREAS, JANITOR CLOSETS, SOILED UTILITY, HOUSE KEEPING, AND TOILET WALLS AND CEILING PAINT SHALL BE WASHABLE SEMI-GLOSS FINISH. P6. CONTRACTOR TO ENSURE THAT PAINT FORMULATION IS APPROPRIATE TO SUBSTRATE WHICH IT IS APPLIED. P7. ALL GYPSUM BOARD SOFFITS AND CEILINGS SHALL BE PAINTED PT-2 U.N.O. IN INTERIOR ELEVATIONS. TILE T1. PROVIDE CEMENTITIOUS BOARD BEHIND ALL TILE IN WET AREAS. T2. ANY VERTICAL WALL TILE TERMINATION SHALL BE FINISHED WITH SCHLUTER "SCHIENE" TRIM PROFILE AT EXPOSED EDGE; SCHLUTER FINISH TO BE STAINLESS STEEL. T3. ALL PORCELAIN WALL TILE WAINSCOTS SHALL BE MINIMUM 48" HIGH, INCLUDING BULLNOSE FINISH TRIM, EXTENDING ABOVE ELEC. SWITCH PLATES, U.N.O. IN INTERIOR ELEVATIONS. WOOD W1. ALL HARDWOOD TO BE MAPLE OR APPROVED EQUAL. IF MAPLE IS UNAVAILABLE, SAMPLE OF ALTERNATE WITH STAIN APPLIED TO BE PROVIDED TO DESIGNER FOR APPROVAL. W2. ALL WOOD DIMENSIONS SHOWN ARE NOMINAL. W3. ALL STAIN GRADE CUSTOM MILLWORK TO BE WD-1, U.N.O. TRIM TR1. PROVIDE INSIDE AND OUTSIDE CORNER TRIM PIECES AT ALL RESILIENT VINYL OR RUBBER AND COVE TILE BASE SPECIFICATIONS. TR2. ALL HOLLOW METAL DOORS AND FRAMES SHALL BE PAINTED TO MATCH THE ADJACENT WALL COLOR IN PROPER PAINT FORMULATION U.N.O. TR3. ALL WOOD DOORS AND FRAMES SHALL BE PAINTED PT-2, U.N.O. TR4. ALL CROWN MOULDING AND CEILING TRIM SHALL BE PAINTED PT-2 U.N.O. AND SHALL BE APPLIED AT WALL/CEILING TRANSITION ON GYPSUM BOARD CEILINGS ONLY. LAY-IN SCHEDULED TO RECEIVE ACT SHALL NOT RECEIVE CROWN MOULDING. TR5. ALL VINYL OR RUBBER BASE SHALL BE ADHERED AT TOP, BOTTOM AND ANY SEAMS. TR6. ALL STANDING & RUNNING MILLWORK TRIM SHALL BE PAINTED PT-2 U.N.O. TR7. ALL ELEVATOR DOORS & TRIM TO BE PAINTED PT-2 U.N.O. TR8. ALL FIRE EXIT DOORS & TRIM TO BE PAINTED PT-2 U.N.O. FLOORING F1. REFERENCE INTERIOR FINISH SCHEDULE FOR TYPICAL FLOOR FINISH TRANSITION SPECIFICATIONS. F2. JOHNSONITE SUBFLOOR LEVELER SYSTEM (LS-40) TO BE USED AT ALL FLOOR FINISH TRANSITIONS, U.N.O. F3. ALL FLOORING MATERIAL TRANSITIONS SHALL OCCUR AT CENTER OF OPENING DEPTH. ALL TRANSITIONS AT DOORS SHALL OCCUR AT CENTERLINE OF DOOR THICKNESS U.N.O. F4. ALL VINYL AND PORCELAIN FLOOR TILE PATTERNS SHALL BE CENTERED ON ROOM U.N.O. NOTED ON ENLARGED FINISH PLANS. CASEWORK C1. ALL EXPOSED INTERIOR SURFACES OF ALL CABINETRY TO BE FINISHED TO MATCH EXTERIOR, U.N.O. C2. ALL SEMI-EXPOSED SURFACES TO BE CLEAR FINISH. C3. ALL CABINETS WITH ADJUSTABLE SHELVES TO HAVE 6MM ∅ HOLES AT 64MM ON CENTER VERTICALLY FOR SHELF SUPPORTS. C4. ALL DRAWER GLIDES TO HAVE A MINIMUM 100 LB CAPACITY AND FULL EXTENSION, U.N.O. C5. ALL CABINETRY HINGES TO BE CONCEALED SELF CLOSING HINGES, U.N.O. C6. DECORATIVE HARDWARE PULLS AT ALL FRONT OF HOUSE COMMON AREAS: EQ-1 (REFER TO INTERIOR LIST OF FINISHES FOR EXACT SPECIFICATION) DECORATIVE HARDWARE PULLS AT ALL BACK OF HOUSE MILLWORK: EQ-2 (REFER TO INTERIOR LIST OF FINISHES FOR EXACT SPECIFICATION) DECORATIVE HARDWARE PULLS AT ALL RESIDENT UNITS: UEQ-1 (REFER TO INTERIOR LIST OF FINISHES FOR EXACT SPECIFICATION) UNITS U1. REFERENCE FINISH SCHEDULE FOR FINISH SPECIFICATION AND LOCATION IN ALL RESIDENT UNITS. U2. RESIDENT UNIT ENTRY DOOR/TRIM FINISH: COMMON AREA/CORRIDOR SIDE: DOOR & TRIM PAINTED PT-2 INSIDE IL RESIDENT UNIT: DOOR & TRIM TO BE PAINTED UPT-2 KEYED NOTES 1. SS5 PROPOSES TO ELIMINATE WINDOWS AND WALLS. WING WALLS TO DEFINE SPACE. 2. SS5 PROPOSES TO EXTEND 6" FULL HEIGHT PARTITION WALLS TO CREATE ADDITIONAL STORAGE IN RECEPTION AREA. 3. TILE TO EXTEND FULL HEIGHT ON WET WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 4. TR-2 TO SURROUND SLAB MIRROR. 5. PHYSICAL THERAPY - MIRRORS TO BE SPECIFIED, PURCHASED & INSTALLED BY GC. 6. SS5 PROPOSES TO EXTEND 6" FULL HEIGHT PARTITION WALL. REFER TO INTER. ELEVATION FOR ADDITIONAL INFORMATION. 7. sS5 PROPOSES 3 LAYER GYP.BUILD UP; 8" WIDE AND 2-1/4" DEEP FROM ON WALL AND CEILING. RE: INT. ELEV. AND DETAILS FOR ADDITIONAL INFORMATION. TYPICAL PUBLIC RESTROOM TYPICAL OFFICE PT-2 PT-1/WP-2 RB-2 SC-1 PL-1,2 -- TYPICAL JANITOR'S CLOSET PT-2 PT-1 RB-2 CPT-4 - - PT-2 PT-1/TR-2/WT-1,2 RB-1/WT-1 FT-1 SSM-1/PL-2 3,4 TYPICAL CLEAN LINEN / CLEAN UTILITY PT-2 PT-1 RB-2 VF-9 PL-1,2 -- TYPICAL BATH PT-2 PT-1/WT-1 WT-1 FT-1,3 SSM-1/PL-2 -- TYPICAL NOURISHMENT STATION PT-2 PT-1/WP-2 RB-2 VF-9 -- -- TYPICAL I.T. PT-2 PT-1 RB-2 SC-1 -- -- TYPICAL MED. PREP PT-2 PT-1 RB-2 VF-9 PL-1,2 -- TYPICAL SOIL UTILITY/ SOIL LINEN PT-2 PT-1/WP-2 RB-2 VF-9 PL-1,2 -- TYPICAL SUPPLY STORAGE PT-2 PT-1 RB-2 SC-1 PL-1,2 -- TYPICAL NURSES STATION PT-2 PT-1 RB-1 VF-1 PL-1,2 -- PT-2 PT-1 RB-2 SC-1 PL-1,2 -- TYPICAL CLOSET PT-2 PT-1 RB-2 VF-9 - - TYPICAL PANTRY PT-2 PT-1 RB-2 SC-1 -- -- TYPICAL EQUIPMENT STORAGE MILLWORK/REVEAL SCHEDULE (N.T.S.) LABEL IMAGE MANUFAC. MODEL/SIZE LOCATION LABEL IMAGE MANUFAC. MODEL/SIZE LOCATION LABEL IMAGE MANUFAC. MODEL/SIZE LOCATION TR-1 S&S CRAFTSMEN. SSI-484 LIVING ROOMS, DINING ROOMS, COMMUNITY ROOMS TR-2 S&S CRAFTSMEN. SSI-632 PUBLIC RESTROOMS TYPICAL STAFF TOILETS PT-2 PT-1/TR-2/WT-1 RB-2/WT-1 FT-1 SSM-1/PL-2 3,4 1 1 1 811 Barton Springs Rd. Ste 800 Austin, TX 78704 v 512 476 6501 f 512 579 5283 www.studioSIX5.com studio SIX 5 SHEET NUMBER : PHASE: OWNER : REVISIONS : SEAL: SHEET DESCRIPTION : DATE : SABER HEALTHCARE 100% CONSTRUCTION SET MOCKSVILLE HEALTH & REHAB CENTER MOCKSVILLE, NORTH CAROLINA APRIL 12, 2017 PRELIMINARY BID SET - 12/23/16 RFI-009 - 01/04/18 1 COVER SHEET I-0.00
20
Embed
studio - jmc-gc.comjmc-gc.com/Project Pages Bids/Plans/Autumn Care Mocksville/2018.01...p6.contractor to ensure that paint formulation ... u1.reference finish schedule for finish specification
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
PT-3
CEILING FINISH
WALL FINISH
BASE FINISH
FLOOR FINISH
DENOTES EXTENT OF A
SPECIFIC WALL FINISH
KEYED NOTE TAG
RE: KEYED NOTES LEGEND
ON SAME SHEET
01
I-6.XX
XX
I-6.XX
XX
XX
XX
XX
ELEVATION TAGS
I-2.XX
XX
ENLARGED PLAN TAG
SECTION TAG
XX/I-7.XX
1
REVISION TAG
INTERIORS SHEET INDEX
REVISION # SHEET # DRAWING TITLE
I-0.00 COVER SHEET
I-0.01 FINISH SCHEDULE
I-0.02 FINISH SCHEDULE
I-0.03 DECORATIVE LIGHTING SCHEDULE
I-1.00AFIRST FLOOR FINISH PLAN, AREA "A"
I-1.00BFIRST FLOOR FINISH PLAN, AREA "B"
I-1.00CFIRST FLOOR FINISH PLAN, AREA "C"
I-1.00DFIRST FLOOR FINISH PLAN, AREA "D"
I-1.00EFIRST FLOOR FINISH PLAN, AREA "E"
I-2.00 ENLARGED UNIT PLANS
I-3.00 ENLARGED FLOORING LAYOUT
I-4.00AWALL PROTECTION PLANS, AREA "A"
I-4.00BWALL PROTECTION PLANS, AREA "B"
I-4.00CWALL PROTECTION PLANS, AREA "C"
I-4.00DWALL PROTECTION PLANS, AREA "D"
I-4.00EWALL PROTECTION PLANS, AREA "E"
I-6.00 INTERIOR ELEVATIONS
I-6.01 INTERIOR ELEVATIONS
I-6.02 INTERIOR ELEVATIONS
I-7.00 DETAILS
XX-X
XX-X
XX-X
XX-X
XX-X/XX-X
X, X, X
COUNTERTOP FINISH/CABINET FINISH
KEYED NOTES
TYPICAL ROOM FINISHES, U.N.O.SYMBOLS LEGEND
AFF
CL
CLG
CLR
DIA
DIM
DWG
EA
ELEV
EQ
FIXT
FLR
FO
GYP
HDWD
INT
MAX
MIN
MTL
NIC
NTS
OC
OH
PLYD
RCP
SCHED
SIM
TYP
UNO
VIF
ABOVE FINISHED FLOOR
CENTERLINE
CEILING
CLEAR
DIAMETER
DIMENSION
DRAWING
EACH
ELEVATION
EQUAL
FIXTURE
FLOOR
FACE OF
GYPSUM WALL BOARD
HARDWOOD
INTERIOR
MAXIMUM
MINIMUM
METAL
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OPPOSITE HAND
PLYWOOD
REFLECTED CEILING PLAN
SCHEDULED
SIMILAR
TYP
UNLESS NOTED OTHERWISE
VERIFY IN FIELD
NOTE:
1. ALL ABBREVIATIONS LISTED ABOVE MAY NOT BE USED ON THIS
PROJECT.
2. ABBREVIATIONS FOR FINISHES CAN BE FOUND ON THE FINISH
SCHEDULE.
ABBREVIATIONS
GENERAL NOTES
G1. GENERAL CONTRACTOR TO COORDINATE ALL BLOCKING; LAYOUT DIMENSIONS AND PENETRATIONS REQUIRED.
G2. ALL CONSTRUCTION MATERIALS, FIXTURES, FINISHES, ETC. ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
G3. CONTRACTOR TO PROVIDE PRODUCT CERTIFICATES & SHOP DRAWINGS OF ALL MILLWORK/CASEWORK AND SAMPLES OF ALL FINISHES AND
ARCHITECTURAL SPECIALTY ITEMS FOR APPROVAL.
G4. PROVIDE WOOD BLOCKING BEHIND ALL WALL MOUNTED ITEMS.
G5. THESE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. IN THE EVENT OF AN INCORRECT OR AN OMISSION OF NECESSARY
DIMENSIONS CONTRACTOR SHALL NOTIFY INTERIOR DESIGNER OR OWNER'S REPRESENTATIVE.
G6. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS PRIOR TO CONSTRUCTION AND NOTIFY INTERIOR DESIGNER OF ANY
DISCREPANCIES THAT COULD EFFECT THE DESIGN AND FINISH OUT OF THE PROJECT.
G7. DO NOT SUSPEND ANY ITEMS FROM METAL ROOF DECKS, HORIZONTAL BRIDGING, X-BRACING, PIPES OR CONDUITS, OR ANY OTHER WORK BY OTHER
TRADES.
G8. EACH CONTRACTOR SHALL COMPLY WITH ALL PROVISIONS OF ALL APPLICABLE LAWS AND ORDERS OF PUBLIC OFFICIALS WITH JURISDICTION FOR
SAFETY OF PERSONS AND PROPERTY.
G9. VERIFY WITH MANUFACTURER OR SUPPLIER THE SIZE, LOCATION, AND CHARACTERISTICS OF ALL WORK AND EQUIPMENT THAT IS TO BE FURNISHED BY
OWNER OR OTHER CONTRACTORS PRIOR TO ANY CONSTRUCTION PERTAINING TO THE SAME IS BEGUN.
G10. WHERE MULTIPLE FINISHES ARE LISTED IN THE SAME ROOM, OR ON THE SAME WALL, REFER TO INTERIOR FINISH PLANS AND/OR INTERIOR ELEVATIONS
FOR APPLICATION.
G11. INSTALL WP-2 AT ALL EXPOSED UNDERCOUNTER SPACES IN FOOD SERVICE AREAS.
G12. ELEC. SWITCH/OUTLET & COVER PLATE COLOR TO BE WHITE, U.N.O.
G13. REFER TO INTERIORS COVER SHEET FOR ALL BACK OF HOUSE FINISHES AND TYPICAL FINISHES.
G14. ALL KEYED NOTES ON BACK OF HOUSE AND TYPICAL FINISH TAGS REFERENCE THE KEYED NOTES ON THE FINISH FLOOR PLANS.
G15. ALL KEYED NOTES MAY NOT BE USED ON EVERY SHEET.
G16. INTERIOR DESIGNER TO BE NOTIFIED OF ALL CEILING HEIGHT CHANGES OR CONFLICTS THAT DO NOT COMPLY WITH THESE DRAWINGS.
G17. REFER TO ARCH. / M.E.P. DRAWINGS FOR ALL PLUMBING EQUIPMENT, U.N.O.
G18. REFER TO FOOD SERVICE DRAWINGS FOR ALL FOOD SERVICE EQUIPMENT, U.N.O.
PAINT
P1. CONTRACTOR SHALL PROVIDE 6'-0"X6'-0" MOCK UPS OF EACH PAINT COLOR AND CONTACT INTERIOR DESIGNER TO SCHEDULE SITE VISIT TO CONFIRM
EACH PRIOR TO APPLICATION.
P2. ALL KITCHEN PREP WALL AND CEILING AREAS SHALL BE PAINTED WITH EPOXY PAINT.
P3. MECHANICAL GRILLES AND WALL DIFFUSERS, ELECTRICAL PANELS, ACCESS PANELS, ETC. WHICH ARE EXPOSED IN FINISHED SPACES SHALL BE
PAINTED, IN PROPER PAINT FORMULATION, TO MATCH THE SURFACE ON WHICH THEY OCCUR.
P4. TYPICAL OVERALL PAINT FINISHES (U.N.O.):
WALLS: EGG SHELL / SATIN
TRIM: SEMI-GLOSS
CEILING: FLAT
CMU: SEMI-GLOSS
DOORS & FRAME: SEMI-GLOSS
P5. ALL FOOD SERVICE AREAS, JANITOR CLOSETS, SOILED UTILITY, HOUSE KEEPING, AND TOILET WALLS AND CEILING PAINT SHALL BE WASHABLE
SEMI-GLOSS FINISH.
P6. CONTRACTOR TO ENSURE THAT PAINT FORMULATION IS APPROPRIATE TO SUBSTRATE WHICH IT IS APPLIED.
P7. ALL GYPSUM BOARD SOFFITS AND CEILINGS SHALL BE PAINTED PT-2 U.N.O. IN INTERIOR ELEVATIONS.
TILE
T1. PROVIDE CEMENTITIOUS BOARD BEHIND ALL TILE IN WET AREAS.
T2. ANY VERTICAL WALL TILE TERMINATION SHALL BE FINISHED WITH SCHLUTER "SCHIENE" TRIM PROFILE AT EXPOSED EDGE; SCHLUTER FINISH TO BE
STAINLESS STEEL.
T3. ALL PORCELAIN WALL TILE WAINSCOTS SHALL BE MINIMUM 48" HIGH, INCLUDING BULLNOSE FINISH TRIM, EXTENDING ABOVE ELEC. SWITCH PLATES,
U.N.O. IN INTERIOR ELEVATIONS.
WOOD
W1. ALL HARDWOOD TO BE MAPLE OR APPROVED EQUAL. IF MAPLE IS UNAVAILABLE, SAMPLE OF ALTERNATE WITH STAIN APPLIED TO BE PROVIDED TO
DESIGNER FOR APPROVAL.
W2. ALL WOOD DIMENSIONS SHOWN ARE NOMINAL.
W3. ALL STAIN GRADE CUSTOM MILLWORK TO BE WD-1, U.N.O.
TRIM
TR1. PROVIDE INSIDE AND OUTSIDE CORNER TRIM PIECES AT ALL RESILIENT VINYL OR RUBBER AND COVE TILE BASE SPECIFICATIONS.
TR2. ALL HOLLOW METAL DOORS AND FRAMES SHALL BE PAINTED TO MATCH THE ADJACENT WALL COLOR IN PROPER PAINT FORMULATION U.N.O.
TR3. ALL WOOD DOORS AND FRAMES SHALL BE PAINTED PT-2, U.N.O.
TR4. ALL CROWN MOULDING AND CEILING TRIM SHALL BE PAINTED PT-2 U.N.O. AND SHALL BE APPLIED AT WALL/CEILING TRANSITION ON GYPSUM BOARD
CEILINGS ONLY. LAY-IN SCHEDULED TO RECEIVE ACT SHALL NOT RECEIVE CROWN MOULDING.
TR5. ALL VINYL OR RUBBER BASE SHALL BE ADHERED AT TOP, BOTTOM AND ANY SEAMS.
TR6. ALL STANDING & RUNNING MILLWORK TRIM SHALL BE PAINTED PT-2 U.N.O.
TR7. ALL ELEVATOR DOORS & TRIM TO BE PAINTED PT-2 U.N.O.
TR8. ALL FIRE EXIT DOORS & TRIM TO BE PAINTED PT-2 U.N.O.