Top Banner
1 Structured labeling for home use devices – assessment of the SPL format Myron Finseth Principal Technical Writer Medtronic Cardiac Rhythm and Disease Management (CRDM) Technical Communications FDA Workshop, April 30, 2013 Accessible Medical Device Labeling in a Standard Content and Format
12

Structured labeling for home use devices – assessment of the SPL format

Dec 03, 2014

Download

Documents

Myron Finseth

Examination of the SPL format for medical device labeling
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Structured labeling for home use devices – assessment of the SPL format

1

Structured labeling for home use devices – assessment of the SPL format

Myron Finseth

Principal Technical Writer

Medtronic Cardiac Rhythm and Disease Management (CRDM)

Technical Communications

FDA Workshop, April 30, 2013

Accessible Medical Device Labeling in a Standard Content and Format

Page 2: Structured labeling for home use devices – assessment of the SPL format

2

Structured labeling for home use devices

• Overview:– About Medtronic CRDM– HL7 Structured Product Labeling (SPL) format– SPL for home use devices – analysis– Considerations

Page 3: Structured labeling for home use devices – assessment of the SPL format

3

About Medtronic CRDM

Cardiac Rhythm and Disease Management (CRDM)• Cardiac resynchronization therapy• Implantable cardiac defibrillators• Pacemakers• Heart monitors

Page 4: Structured labeling for home use devices – assessment of the SPL format

4

CRDM home use device labeling

• Document types:– Clinician manual– Patient manual

• Audiences:– Physicians, clinicians– Home healthcare nurses and aides– Patients– Regulatory authorities (US and International)

Page 5: Structured labeling for home use devices – assessment of the SPL format

5

HL7 Structured Product Labeling (SPL) format

Data elements

Content of labeling(text from manuals)

HL7 SPL R5 data model

Instructions for use

Troubleshooting

Warnings

Precautions

Contraindications

Adverse events

Manufacturer’s contact information

Lot number /and serial number

Special storage conditionsSterilizationContains latexContain human tissueControlled by lot / serial #KitCombo productControlled byProduct exempt from DPMPackage sterile?

UDICompany name /addressContact informationBrand nameModel / version #GMDNUnit of useDevice countLabeler companyStorage and handling

HL7 Health Informatics include data standards for Electronic Health Records, Patient Health Records, and mobile health information.

Page 6: Structured labeling for home use devices – assessment of the SPL format

6

• Reveal XT Patient Assistant– Patients use the device to mark points of

time when they experience fainting spells.– Clinicians or home healthcare

professionals train patients on how to use the device.

– Medtronic REVEAL Patient Assistant 9538/9539 Clinician Manual used for training.

Reveal XTPatient Assistant

Reveal XTimplantable heart monitor

SPL for home use devices - analysis

Page 7: Structured labeling for home use devices – assessment of the SPL format

7

SPL for home use devices - analysis

• Objectives:– Assess how the RTI study(1)

recommendations align with Reveal Clinician manual.

– Assess how the proposed UDI data elements support the text from the Reveal Clinician manual.

– Better understand how a standardized labeling submission could impact device labeling.

1 Medical Device Labeling for Health Care Practitioners Focus Group Study, Final Report. Presented to Food and Drug Administration. Research Triangle Institute (RTI) International. 2011.

Page 8: Structured labeling for home use devices – assessment of the SPL format

8

Alignment with the RTI study

• Reveal Clinician manual aligns well with the RTI study.

• Some rearranging of sections and editing were necessary.

• Tables and graphics appeared as they do in the printed manual.

• “Indications” should be included as part of the required sections.

• Lot and serial number should be in the data elements section only.

Recommended sections Existing content sufficient?

Instructions for use Yes

Troubleshooting Yes

Warnings Yes

Precautions Yes

Contraindications Yes

Adverse events Yes

Contact information Yes

Lot and serial number* Yes

Page 9: Structured labeling for home use devices – assessment of the SPL format

9

Alignment with UDI data elements

• The UDI data element connects the specific device to the correct labeling.

• Including the data elements along with the content of labeling better represents content from existing manuals.

• Makes sense to use device data elements in a similar way as drug and biologic products.– Support combination products– Maintain continuity in labeling

for all regulated products.

Highlighted data elements represent content from the existing Reveal manual.

Page 10: Structured labeling for home use devices – assessment of the SPL format

10

Implantable CRT device - patient manual

• Patient manual is largely informational. Rather than “how to operate” a device, this manual informs “how to live” with their device.– Implant procedure and recovery– Registration, follow-up care, contact

information– Precautions, medical procedures, EMI

• Can be aligned closely to RTI sections and UDI data elements.

• Possible use for distribution to electronic patient health record, including mobile device delivery.

Active implantable devices represent the majority of CRDM products.

Page 11: Structured labeling for home use devices – assessment of the SPL format

11

Considerations

• The RTI recommended sections do not add new content. The effort to implement would involve restructuring and editing existing content.

• The HL7 SPL data model allows new opportunities for labeling distribution (dedicated website for devices, Health Information Systems, Patient Health Records, and mobile devices).

• The required format needs to be a global solution. We recommend adoption through IMDRF (International Medical Device Regulators Forum) UDI Guidance.

Page 12: Structured labeling for home use devices – assessment of the SPL format

12

Considerations

• Make the Labeling submission separate from the UDI submission and Device Listing submission. Perhaps, include SPL as part of the final labeling submission for PMA products and something similar for 510(k) submissions.

• Industry needs the ability to choose or develop their own software to implement the requirement and sufficient time for deployment.

• Some data elements lack clear definition (e.g., model / brand). Implementation of any solution requires that better definitions be developed and harmonized across all agency uses of those terms.