This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Stations Width (in.) Height (in.) Depth (in.) Residential/CommercialRainBIrd Controllers EC Controller 4-9 stations 6.50 5.50 1.75 R ESP-TM 4-8 stations 7.00 8.25 2.25 R ESP-Modular 4-13 stations 11.00 8.00 4.50 RESP-LX Plus / LXi Plus 6-24 stations 9.50 10.25 4.50 R/C ESP-LX Modular 8-32 stations 14.50 12.75 5.50 R/C ESP-MC 8-40 stations 11.50 11.50 6.50 C IQ LXM-DTC 8-32 stations 14.50 12.75 5.50 C MDC (2 wire systems) 1-200 decoders 11.00 12.00 5.50 C TWI (2 wire Interface) 28 satellites 15.50 12.50 6.00 C LDI / SDI (Lg/Sm Decoder Interface) 1-200 decoders 9.50 10.25 4.50 C CCU-6 (Cluster Control) 6 satellites 11.50 11.50 6.50 C CCU-28 (Cluster Control) 28 satellites 11.50 11.50 6.50 C ESP-SAT 12-40 stations 11.50 11.50 6.50 C ESP-SITE SAT 12-40 stations 11.50 11.50 6.50 C RainMaster RME Sentar II SE 6-36 stations 13.25 10.25 4.75 C SE-B / SE-SB 6-36 stations 13.25 18.00 4.50 C RME Eagle EG 6-36 stations 13.25 10.25 4.75 C EG-B / EG-SB 6-36 stations 13.25 18.00 4.50 C RME Eagle-I central 6-36 stations 13.25 10.25 4.75 C Egi-B / Egi-SB 6-36 stations 13.25 18.00 4.50 C RME - DX2 Evolution 6-48 stations 13.25 10.25 4.75 C Toro DDC-WP 2-8 stations 5.75 5.00 2.00 R DDC 4-8 stations 3.50 8.50 7.00 R TMC-212 outdoor 2-12 stations 13.00 9.50 3.50 R/C TMC-424 4-24 stations 15.25 10.25 5.25 C TIS-612 6-12 stations 9.75 7.50 5.75 C TIS-240 24 stations 11.75 8.50 5.75 C Custom Command Plastic 12-24 Station 12-24 stations 11.50 6.00 8.50 C Metal 12-24 Station 12-24 stations 10.75 9.75 5.75 C Metal 36-48 Station 36-48 stations 10.75 15.75 5.75 C TDC-100/200 100, 200 decoders 14.00 13.00 6.00 C Sentinel WallMount 12-48 stations 10.75 15.75 5.75 C Irritrol RainDial Series 6-12 stations 7.75 10.75 4.00 R Smart Dial 6-24 stations 7.75 10.75 4.00 R Total Control Series 6-24 stations 8.50 10.50 5.00 R KwikDial Series 4-12 stations 9.00 7.00 4.00 R JR Max Series 4-8 stations 8.00 6.75 4.00 R MC-E Series 4-48 stations 9.75 10.50 4.25 C IBOC Plus 4-12 stations 9.25 10.75 5.25 C
Hunter I-Core-600-PL 6 stations mod. 13.50 11.00 6.50 C I-Core-600-M 6 stations mod. 15.50 12.50 6.50 C PRO-C Series 3-15 stations 9.00 10.00 4.50 C ICC-Series 8-32 stations 11.00 13.25 4.75 C ICC-M Series 8-48 stations 12.25 16.00 4.75 C ACC Series 12-48 stations 12.50 15.50 6.50 C ACC 990 99 stations 12.50 15.50 6.50 C ET Module 6.00 4.00 2.00 C AquaConserve ET- 8 8-12 stations 9.00 8.75 3.25 R ET-16 Series 16-32 stations 9.75 10.75 4.25 R ULTIMO Series 16-66 stations 12.00 14.25 4.75 R/C Signature Constellation 8-24 stations 14.00 12.75 4.25 C 28-48 stations 14.00 18.00 4.25 C Galaxy 8-48 stations 14.00 12.75 4.25 C 28-48 stations 14.00 18.00 4.25 C HydroPoint ET Plus 9-24 stations 6.00 7.00 1.00 R WeatherTRAK ET Pro 2 12-24 stations 9.75 10.50 4.25 R/C WeatherTRAK ET Pro 2 28-48 stations 9.75 10.50 4.25 R/C
Calsense ET2000 8-40 stations 11.15 11.40 7.25 C ET2000e 8-48 stations 11.15 11.40 7.25 C
3
RainBIrd Controllers EC Controller x x x x xESP-TM x x x x xESP-Modular x x x x xESP-LX Plus / LXi Plus x x xx xx xx x x x x xESP-LX Modular x x xx xx xx x x ESP-MC x x xx xx xx x x xx x x xIQ LXM-DTC x x xx xx xx x x x x xMDC (2 wire systems) x x xx xx xx x x x x x xTWI (2 wire Interface) x x xx xx xx x LDI / SDI (Lg/Sm Decoder Interface) x x xx xx xx x x x xCCU-6 (Cluster Control) x x xx xx xx x x x x xCCU-28 (Cluster Control) x x xx xx xx x x x x xESP-SAT x x xx xx xx x x x x x xESP-SITE SAT x x xx xx xx x x x x x x RainMaster RME Sentar II SE x x xx xx xx x x x x x xSE-B / SE-SB x x xx xx xx x xRME Eagle EG x x xx xx xx x x x x x xEG-B / EG-SB x x xx xx xx RME Eagle-I central x x xx xx xx x x x x x xEgi-B / Egi-SB x x xx xx xx x xRME - DX2 Evolution x x xx xx xx x x x x x x Toro DDC-WP x x x x xDDC x x x x xTMC-212 outdoor x x xx xx xx x x x x x xTMC-424 x x xx xx xx x xTIS-612 x x xx xx xx x x x x x xTIS-240 x x xx xx xx x x x x x xCustom Command Plastic 12-24 Station x x xx xx xx x x x x x x Metal 12-24 Station x x xx xx xx x x x x x x Metal 36-48 Station x x xx xx xx TDC-100/200 x x xx xx xx x x x x xSentinel WallMount x x xx xx xx x Irritrol RainDial Series x x x x xSmart Dial x x x x xTotal Control Series x x x x xKwikDial Series x x x x xJR Max Series x x x x xMC-E Series x x xx xx xx x x x x x xIBOC Plus x x xx xx xx x x x x x x
Hunter SRC-Series x x x x xXC-Series x x x x xPRO-C Series x x xx xx xx x x x x x xICC-Series x x xx xx xx x x x x x xICC-M Series x x xx xx xx x xACC Series x x xx xx xx x xACC 990 x x xx xx xx x xET Module x x x x x AquaConserve ET- 8 x x x xET-16 Series x x x xULTIMO Series x x xx xx xx x x x Signature Constellation x x xx xx xx x x x x xx xx xxGalaxy x x xx xx xx x x x x xx xx xx HydroPoint ET Plus x x xx xx xx x x x x x xWeatherTRAK ET Pro 2 x x xx xx xx x x x x x xWeatherTRAK ET Pro 2 x x xx xx xx x x x x x x
Calsense ET2000 x x xx xx xx x x x x x xET2000e x x xx xx xx x x x x x x
SB-1
8SS
Fron
t Ent
ry P
edes
tal
18” x
36”
x 1
2”
SB-2
4SS
Fron
t Ent
ry P
edes
tal
24” x
36”
x 1
2”
SB-3
6SS
Fron
t Ent
ry P
edes
tal
36” x
36”
x 1
2”
SB-1
8DSS
Fron
t Ent
ry P
edes
tal
18” x
36”
x 2
4”
SB-2
4DSS
Fron
t Ent
ry P
edes
tal
24” x
36”
x 2
4”
SB-1
6SSW
Fron
t Ent
ry W
all M
ount
16
” x 1
8” x
12”
SB-1
6SS
Top
Entry
Ped
esta
l 16
” x 3
8” x
15.
5”
SB-2
2SS
Top
Entry
Ped
esta
l 24
” x 3
8” x
17”
LD-1
6S L
ight
Dut
yFr
ont E
ntry
Ped
esta
l 16
” x 3
0” x
8”
LD-1
6SW
Lig
ht D
uty
Fron
t Ent
ry W
all M
ount
16
” x 3
0” x
8”
LD-1
8SW
Lig
ht D
uty
Fron
t Ent
ry W
all M
ount
18
” x 1
8” x
8”
x Room for one controllerxx Room for two controllers
4
THE uLTIMATE FrOnT EnTrY EnCLOSurEWEATHEr rESISTAnT—VAnDAL rESISTAnT• 100%stainlesssteelconstructionassureslong-term,rustproofdurabilityandadditionalstrength• Threepointlockingmechanism,flushmountedaccesshandleandheavydutycontinuoushingeensures
maximum security• Removable,predrilledbackboardprovidesforeasyinstallationandanattractivefinishedproduct• Chameleoneffectofthenaturalbrushedstainlesssteelfinishprovidesanunobtrusivequality• Largedoormountedstorageareaandliteraturestoragepocketprovideseasyaccesstoplansand
THE uLTIMATE FrOnT EnTrY EnCLOSurEWEATHEr rESISTAnT—VAnDAL rESISTAnT• 100%stainlesssteelconstructionassureslong-term,rustproofdurabilityandadditionalstrength• Threepointlockingmechanism,flushmountedaccesshandleandheavydutycontinuoushingeensures
maximum security• Removable,predrilledbackboardprovidesforeasyinstallationandanattractivefinishedproduct• Chameleoneffectofthenaturalbrushedstainlesssteelfinishprovidesanunobtrusivequality• Largedoormountedstorageareaandliteraturestoragepocketprovideseasyaccesstoplansand
THE uLTIMATE TOP EnTrY EnCLOSurEWEATHEr rESISTAnT—VAnDAL rESISTAnT• 100%stainlesssteelconstructionassureslong-term,rustproofdurabilityandadditionalstrength• Threepointlockingmechanism,flushmountedaccesshandleandheavydutycontinuoushinge
nEMA 3Sx & 4x EnCLOSurES AVAILABLE FOr OEM DESIGnWEATHEr rESISTAnT – VAnDAL rESISTAnT TheStrongBoxNEMATYPE3SXSerieswasdesignedtooperate even in the coldest climates with ice formation aroundcabinet.Our3SXSeriesisavailableaswallmountor pedestal mount. When covering electronics or controllers and protecting them from the harsh elements like snow and icebuildup,thenwehavetheenclosureforyou.
nEMA Enclosure TypesType 3R:Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipmentinsidetheenclosureagainstingressofsolidfor-eignobjects(fallingdirt);toprovideadegreeofprotectionwithrespecttoharmfuleffectsontheequipmentduetotheingressofwater(rain,sleet,snow);andthatwillbeundam-agedbytheexternalformationoficeontheenclosure.Type 3SX:Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipmentinsidetheenclosureagainstingressofsolid foreignobjects(fallingdirtandwindblowndust);toprovidea degree of protection with respect to harmful effects on the equipmentduetotheingressofwater(rain,sleet,snow);that provides an additional level of protection against corrosion; and for which the external mechanism(s) remain operablewheniceladen.Type 4X:Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipmentinsidetheenclosureagainstingressofsolidfor-eignobjects(windblowndust);toprovideadegreeofpro-tectionwithrespecttoharmfuleffectsontheequipmentdueto the ingress of water (rain, sleet, snow, splashing water, and hose directed water); that provides an additional level ofprotectionagainstcorrosion;andthatwillbeundamagedbytheexternalformationoficeontheenclosure.
VAnDAL rESISTAnT EASY ACCCESSPuMP AnD POWEr COnDITIOnErS EnCLOSurE• Marinegradealuminumalloyconstructionprovideslastingdurabilityandstrength,withlightweightfor
ease of handling• 100%stainlesssteelhardwareassureslong-termrustproofdurabilityandadditionalstrength• Fullreleaselockingmechanismrequiresnotoolsandprovideseasyaccessforserviceandrepair• Flush-mountedlockingmechanismandsollidsheetconstructionensuresmaximumsecurity• Chameleoneffectofthenaturalfinishprovidesanunobtrusivequality• Fiveyearlimitedwarranty• Allaluminumenclosuresmaybepowdercoatedinmanycolorsatanadditionalcharge
PuMP & POWEr COnDITIOnErALuMInuM
Power Conditioner Enclosure “A”Length Height WidthSBBC-40ALHPPC40” 39” 24”
Note:Forinsidedimensions,seeBackflowCover Sizing Chart on pages 14-15.
Note:Forinsidedimensions,seeBackflowCover Sizing Chart on pages 14-15.
SPECIFICATIOn On PAGE 54
SPECIFICATIOn On PAGE 55
Contractor installed concrete pad
Contractor installed concrete pad
22
POLAr BEArIErSLIP-On InSuLATInG COVEr
A simple, effective, and stylish waytoinsulatebackflowdevicesto help prevent freezing. The Polar Bearier is a slip-on insulat-ing cover that installs in seconds andremovesevenquickerforbackflowmaintenance.Thisuniquedeviceusesspace age insulation materials to pro-vide R-19 insulation while maintaining a sleek and attractive appearance.The construction materials include:1. A heavy-duty, water repellent
exterior cover of acrylic impregnation coated polyester fabric.Standardcolorsisfor-estgreen.Thismarinefabricisguaranteed for a five year peri-od against excessive loss of color or strength under normal exposure conditions. The coverhasbeendesignedtoberemovable.Customexteriorcolors as well as silk screened agencylogosareavailablebyspecial order.
2. A layer of Radiant Barrier Foil (RBF)thatblocks97%ofradi-
ant heat. This material consists ofalayerofpolyethylenebub-blesbondedtoandsand-wichedbetweentwoindustrialstrength aluminum foil sheets. This material is impervious to moisture, does not promote fungusorbacteriagrowthandisunsuitableforpestnestingmaterial.
3.A1/4"thickpolyolefinfoamlayer for added additional insulation also provides sup-port to the Polar Bearier.
4. R-19 Polar Beariers use a second layer of RBF to provide added insulation.
5. A water repellent lining of 200 deniernylonfabrictoresisttearsfrombackflowparts.
6. A Velcro®stripatthebaseofthe Polar Bearier closes the system to prevent drafts and allows water to exit the cover shouldthebackflowunitdevel-op a leak.
7.Brassgrommetsatthebaseofthe Polar Bearier allow for mul-tiple pad lock security.
Whycontinuetowrapyourback-flowdeviceswithlumpyfiber-glass and tape when you can simply slip on a Polar Bearier? Wrappingabackflowdeviceisexpensiveandthewrapmustbereplaced annually or when the fiberglassbecomeswetinorderto retain the insulating value. In fact,compressionofthefiber-glass material during wrapping significantly reduces the insulat-ingor"R"value.OnaverageaPolarBeariercanbeinstalledonabackflowdeviceforabout1½ times the cost of one year’s wrappingwithineffectivefiber-glass and tape.
• Providesanaesthetic alternative to exposed backflowdevices.
23
Specification of the correct Polar Bearierforyourprojectcanbeeasilyaccomplishedbyusingthefollowing product information.Backflow devices installed in areas where long freezing peri-odscanbeanticipatedshouldbedrainedorprotectedwithbackflowheatingdevices.Determinetheheightoftheback-flowdeviceabovefinishedgrade. Keep in mind that most localcodesrequirethatthebot-tomofthebackflowdevicebe12"abovefinishedgrade.Most1½"and2"backflowdeviceassembliesinstalledtocodewillbebetween20"and24"high.
Usea24"highPolarBearierforthese applications.Pressurebackflowdevicesinstalled12"abovethehighestheadwilloftenrequiretheuse ofthelarger34"and46"highPolar Beariers.Thelengthofthebackflowdeviceassemblyisthemostdiffi-cult dimension to determine. The lengthoftheassemblywillbebasedonthetypeofbackflowdevice used, the size and type of additionalequipmentsuchasregulators and wye strainers, the locationoftheadditionalequip-mentontheassembly,andthelengthofthenipplesbetween
equipment.Fieldmeasurementoftheinstalledequipmentwillresultinthebestdeterminationofassemblylength.Measuretheoveralllengthoftheassemblyandadd6"tofindthesizeofthebackflowcover.Iftheresultingmeasurementfallsinbetweensizes on the Polar Bearier use the larger of the two sizes to insure a correct fit.
COMMErCIAL SErVICE PEDESTAL WITH CuSTOMErAnD EnCLOSurE SECTIOnS• Providesmeteredpowerdistributionforstreetlighting,parklighting,privatedevelopmentlighting, signage, irrigation, pump, and cellular applications• 100%stainlesssteelconstructionassureslongterm,rustproofdurabilityandadditionalstrength• Swingsidetopallowsforfullexposureofmetercompartment• Topiseasiertoopenandcontrolthanfliptops,andlocksopenforsafety• Allstainlesssteelenclosuresmaybepowdercoatedinvariouscolorsatanadditionalcharge• Doubledoordesign• Mountingtemplateandanchorsincluded• Tenyearlimitedwarranty• NEMATYPE3RULListed
* All meter pedestals available with AIC ratings of 22k, 65k and higher. Photocell, time clocks, lighting contractors and circuit breakers available factory installed.
CSP-A SErIES METErED EnCLOSurEDesigned to supply metered power to remote locations. Typical applications include street lighting, traffic signal circuits, parking lot lighting, highway and pump stations and cellular applications.
CSP-B SErIES METErED EnCLOSurEDesigned to supply metered power to remote locations. Typical applica-tions include street lighting, traffic signal circuits, parking lot lighting, highway and pump stations and cellular applications.
COMMErCIAL SErVICE PEDESTALSTAInLESS STEEL
METEr SPECIFICATIOnS•0-200AmpLoadCenterwithup
to 32 Circuits•120V&240VModelsAvailable•TestBlocks•ULListed,NEMATYPE3RRated•EUSERC308Compliant
Commercial Meter Pedestal•SmallCabinetProfilewithSide
GALV. ANCHOR BOLTS5/8” X 18” X 4”WITH 90 DEGREE BEND(4 REQUIRED)
SIDE VIEW FRONT VIEW
22.25”
6” MIN.
12.25”RECOMMENDEDGROUND RODLOCATION
CSP C-SERIES - BASE FOR SERVICEEQUIPMENT ENCLOSURE
LINE
LOAD
CSP-C SErIES METErED EnCLOSurEDesigned to supply metered power to remote locations. Typical applications include street lighting, traffic signal circuits, parking lot lighting, highway and pump stations and cellular applications.
Commercial Meter Pedestal•FlipTopMeterDoor•25”Wx48”Hx16.5”DCabinet•5YearLimitedWarranty
32
COMBInED COMMErCIAL METEr SOCKET WITH THE uLTIMATE EnCLOSurE• Compact,doubledoor,frontandbackdesign,providesviewingandprogrammingconvenience• 100%stainlesssteelconstructionassureslong-term,rust-proofdurabilityandadditionalstrength• Chameleoneffectofthenaturalbrushedstainlesssteelfinishprovidesanunobtrusivequality• Allstainlesssteelenclosuresmaybepowdercoatedinmanycolorsatanadditionalcharge
METEr SECTIOn• ULlisted,E.U.S.E.R.C.309approvedcommercialmetersocket,100amprated,withtestblock
BBS SErIES BATTErY BACKuPTheStrongBoxBatteryBackupSystemTrafficEnclosureisusedtoconcealbatteriesfortrafficsignals.ThesecabinetsmaybemountedtoorwiththeStrongBoxMPSSeriesmeterpedestalsorusedasastandalone pedestal. Our enclosures come with passive ventilation or fan with thermostat, louvers with dust fil-ters, rain channel, gasket and a three point compression locking door.Removableshelvesgiveaccesstothebatterycompartmentsforwiring.TheStrongBoxBBSenclosurecomes configured to accept most Battery Backup Systems for shelf mounted traffic applications.
Our new QuickPad™mountingpadwithsupportbasemakes installation and mounting of Strong Box® enclosureseasierthanever.Noconcreteisneeded.Themountingpadhasouruniquefasteningsystem that allows for easy, secure attachment of the pad to thesupportbaseandtheenclosuretothepad.Together,theheavy-dutypad,supportbaseanda Strong Box® enclosure form a complete unit that is secure,stableandvandalresistant.Theburiedsupportbaseprovidesaddedstabilityandsecurityfortheentireassembly.All mounting hardware is stainless steel to prevent corrosion and rust.PatentNo6,321,928.
QuickPad for Strong Box® Backflow Enclosures DIMENSIONS A BQP-22BF QuickPadforSBBC-22Series 28.5”Wide,19”DeepQP-20BF QuickPadforSBBC-20Series 32"Wide,19"DeepQP-30BF QuickPadforSBBC-30Series 32"Wide,19"DeepQP-45BF QuickPadforSBBC-45Series 49”Wide,19”Deep
SPECIFICATIOn On PAGE 40
35
EnCLOSurEOPTIOnS
36 & 52 STATIOn COnTrOLLEr SuBASSEMBLYThis package includes 120 volt, 15 amp, ground fault protected duplexboxwithreceptacleandlockingswitch:flexibleconduitandcondulet; and terminal strips with placards.
SOLAr SYnC COVErSolar Sync Cover is designed to protect Solar Sync switches from vandalism and made to attach to StrongBox enclosures with gasket seal.
StrongBoxTM manufactures high quality irrigation, plumbing and electrical landscape enclosures for every application. We also offer an extensive line of meter pedestals, tree tying and sprinkler support products for the landscape professional. • Heavydutystainlesssteelfordurability • Weatherandvandalresistant • Promptproductavailability • ExcellentsalesandtechnicalsupportCall or visit our website to specify VIT products for your next project.
38
CInCH-TIE TrEE SuPPOrTSuV resistant Flexible Vinyl
CT24 24”Long.ForStakingofa5-15GallonTreeCT32 32”Long.ForStakingofa24”BoxTreeSold in Bundles of 100
CInCH-BELT TrEE SuPPOrTuV resistant Flexible Vinyl
CB250 250’ Roll For Staking Trees.Comeswith70BucklesPerRoll—ExtraBucklesAreAvailable
TWIST-BrACE TrEE SuPPOrTSnAIL BrACKET STYLE5/16” round metal rod with a 4 1/2” loop encased in uV resistant vinyl tubing
TB24 24”long,forstaking5-15gallonto24”boxtrees
TWIST-BrACE TrEE SuPPOrTSBOLT STYLE1/2” round metal rod with a 4 1/2” loop encased in uV resistant vinyl tubing
TB36 36”long,forstaking24“-36”boxtrees
HOSE & WIrE TrEE SuPPOrTS12 Gauge galvanized wire encased in 10 1/2” long uV resistant vinyl tubing
HW27 27”long,forstaking5-15gallontreesHW36 36”long,forstaking24”boxtreesSold in Bundles of 100
12 Gauge galvanized wire encased in 16” long uV resistant vinyl tubing
HW3616 36”long,forstaking24”boxtreesHW4816 48”long,forstaking24”boxtreesSold in Bundles of 100
TrEE & SPrInKLEr SuPPOrTAnD PrOTECTIOn PrODuCTS
39
TrIM GuArD TrEE TrunK PrOTECTIOn
TG4 Protects trees from tree trimmer damage
PIPE STABILIZEr
UsebetweenthesprinklerheadstocontrolmovementofthepipePS12 12”PipeStabilizerPS18 18”PipeStabilizerPS24 24”PipeStabilizerSold in Bundles of 5
SPrInKLEr STABILIZEr
Use to secure pipe and sprinkler heads to prevent movement,vandalism and damageSS18 18”SprinklerStabilizerSS24 24”SprinklerStabilizerSold in Bundles of 5
STrAIGHT rISEr STABILIZEr
Use to secure risers to prevent movement, vandalism and damage.The steel shaft gives additional support and allows good penetration even in tough soils.RS12 12”StraightRiserStabilizerRS18 18”StraightRiserStabilizerRS24 24”StraightRiserStabilizer
ST9 9”SprinklerTieforshrubsST12 12”SprinklerTieforPop-upsSold in Packs of 50
rATCHET TOOL FOr SPrInKLEr TIES
RT Use to install Sprinkler Ties
TrEE & SPrInKLEr SuPPOrTAnD PrOTECTIOn PrODuCTS
40 40
QuICKPADEnCLOSurE MOunTInG PAD
QP SErIES
The controller enclosure mount-ingpadassemblyshallconsistofa reinforced plastic support base,athreesixteenthinchthick5052H32MarineGradeAluminum mounting pad and stainlesssteelfasteningbrack-ets.Thesupportbaseshallbe
installed and compacted in earth allowing the top two inches of the supportbasetobeexposedabovetheearth.The5052H32Marine Grade Aluminum mount-ingpadshallbeclampedtothesupportbasewiththestainlesssteelfasteningbrackets.The
controllerenclosureshallbebolt-ed from the inside of the enclo-sure to the mounting pad, thus preventing outside access to the mountingbolts.
8. Fillinsidebasewithpeagravel9. QuickPadfasteningbracket(2)10. 120 volt service conduit11. Controllersub-assembly(CSA) includes terminal strips with placards12. Automatic controller
FrOnT EnTrY EnCLOSurEMODELS: SB-18SS, SB-18DSS, SB-24SS,
SB-24DSS, SB36SS
24”
36”
12”4”
12”
Theenclosureshallbeofavandaland weather resistant nature man-ufactured entirely of stainless steel.Themainhousingshallbelouveredupperandlowerbodyto allow for cross flow ventilation. Filter screens shall cover all lou-vers to deflect against water spray, insects and dust. A stain-lesssteelbackboardshallbeprovided for the purpose of mounting electronic and various othertypesofequipment.Thebackboardshallbemountedonfourstainlesssteelboltsthatwill
allowforremovaloftheback-board.Theinsidedoorareashallprovideadequatestorageforplans, operating instructions, and scheduling information. The enclosure door shall have a con-tinuous stainless steel piano hinge,carriageboltedononeside, and a three point locking mechanism on the other side. Theedgeofthedoorshallbehemmed to eliminate any sharp edges. The handle controlling the lockingmechanismshallbelocatedatthebaseofthedoor
andbeconcealedwithinthesur-face of the door. A stainless steel camstylelockshallbemountedin the door and a provision for a padlockshallbeincludedwithinthe locking mechanism. The enclosureshallbemanufacturedwith a continuous drainage chan-nel which mates with a teardrop shaped, hollow center, water-tight, thermoplastic door seal. The abovedescribedproductshallbeaNEMATYPE3RRainproofEnclosureaslistedbyUnderwriterLaboratories,Inc.
5. Directburialcontrolwirestocontrolvalves6. Finish grade7. Controllersub-assembly(CSA)includesGFI & terminal strips with placards8. Automatic controller9. 120 volt service in conduit
InSTALLATIOn DETAILS
SPECIFICATIOnS
DoubleDoorSideView Single Door Side View
42
STAInLESS STEELEnCLOSurE
TOP EnTrY EnCLOSurEMODELS: SB-16SS, SB-22SS
Theenclosureshallbeofavan-dal and weather resistant nature manufactured entirely of stainless steel. The main housing door shallbelouveredatthebottomandequippedwithateardropshaped, hollow center thermo-plastic door seal. The entry lid shallbelouveredonthebackside to allow for cross flow venti-lation. Filter screens shall cover all louvers to deflect against water spray, insects and dust. Thetopentrylidshallbeassist-edbytwogasspringsforeasy
access. The edge of the lid shall behemmedtoeliminateanysharp edges. The top entry lid shall have a continuous stainless steelpianohinge,carriagebolt-ed on the rear, and a three point locking mechanism on the front. A stainless steel cam style lock shallbemountedinthelidandaprovisionforapadlockshallbeincluded within the locking mech-anism.Aremovablestainlesssteeltrayshallbeprovidedforthe purpose of mounting elec-tronics and various other types of equipment.Aremovablestain-
lesssteelbackboardshallbeprovidedinthelowerbodyandmounted on four stainless steel bolts.Theinsidedoorareashallprovideadequatestorageforplans, operating instructions, and scheduling information. The abovedescribedproductshallbeaNEMATYPE3RRainproofEnclosureaslistedbyUnderwriterLaboratories,Inc.
1. Controller enclosure2. 120 volt service in conduit3. Pouredconcretebase—6"min.thickness— extendconcrete6"beyondoutsidedimen sionsofenclosurewith1/2%slopefordrainage4. QuickPadmountingbase
Theenclosureshallbeofavan-dal and weather resistant nature manufactured entirely of stainless steel.Themainhousingshallbelouveredupperandlowerbodyto allow for cross flow ventilation. Filter screens shall cover all lou-vers to deflect against water spray, insects and dust. A stain-lesssteelbackboardshallbeprovided for the purpose of mounting electronic and various othertypesofequipment.Thebackboardshallbemountedonfourstainlesssteelboltsthatwillallowforremovaloftheback-
board.Theinsidedoorareashallprovideadequatestorageforplans, operating instructions and scheduling information. The enclosure door shall have a con-tinuous stainless steel piano hinge,carriageboltedononeside, and a two-point locking mechanism on the other side. Theedgeofthedoorshallbehemmed to eliminate any sharp edges. The handle controlling the lockingmechanismshallbelocatedatthebaseofthedoorandbeconcealedwithinthesur-face of the door. A stainless steel
camstylelockshallbemountedin the door and the provision for apadlockshallbeincludedwith-in the locking mechanism. The enclosureshallbemanufacturedwith a continuous drainage chan-nel which mates with a tear-drop shaped, hollow center, water-tight, thermoplastic door seal. TheabovedescribedproductshallbeaNEMATYPE3RRainproofEnclosureaslistedbyUnderwriterLaboratories,Inc.
1. Controller enclosure2. Wall3. Automatic controller4. 24 volt conduit5. 120 volt conduit
Thecabinetshallbeofaweatherresistant nature manufactured entirely of stainless steel. The mainhousingshallbelouveredupperandlowerbodytoallowfor cross flow ventilation. Filter screens shall cover all louvers to deflect against water spray, insects and dust. A stainless steelbackboardshallbeprovid-
ed for the purpose of mounting electronic and various other typesofequipment.Theback-boardshallbemountedonfourstainlesssteelboltsthatwillallowforremΩovalofthebackboard.Astainless steel cam style lock shallbemountedinthedoor.Thecabinetshallbeequippedwithateardrop shaped, hollow center,
watertight, thermoplastic door seal.Theabovedescribedprod-uctshallbeaNEMATYPE3RRainproofEnclosureaslistedbyUnderwriterLaboratories,Inc.
1. Controllercabinet2. Pouredconcretebase–6"Min.thickness–extend6" beyondoutsidedimensionsofenclosurewith1/2% slope for drainage3. PVC long sweep ell – use one sweep ell per controller
4. Ground rod5. Finish grade6. Controllersub-assembly(CSA)includesGFI and terminal strips with placards7. Automatic controller8. 120-volt service in conduit
InSTALLATIOn DETAILS
SPECIFICATIOnS
LIGHT DuTY CABInETMODEL: LD-16S
45
STAInLESS STEELCABInET
Thecabinetshallbeofaweatherresistant nature manufactured entirely of stainless steel. The mainhousingshallbelouveredto deflect against water spray, insects and dust. A stainless steelbackboardshallbeprovid-ed for the purpose of mounting electronic and various other typesofequipment.Theback-boardshallbemountedonfour
stainlesssteelboltsthatwillallowforremovalofthebackboard.Thecabinetdoorshallhaveacontinuous stainless steel piano hinge on one side with a stain-less steel cam style lock mount-edinthedoor.Thecabinetshallbeequippedwithateardrop,hollow center, watertight, thermo-plasticdoorseal.Thebottomofthecabinetshallbeprepunched
Thecabinetshallbeofaweatherresistant nature manufactured entirely of stainless steel. A stain-lesssteelbackboardshallbeprovided for the purpose of mounting electronic and various typesofequipment.Theback-boardshallbemountedonfourstainlesssteelboltsthatwillallowforremovalofthebackboard.Thecabinetdoorshallhavea
continuous stainless steel piano hinge on one side with a stain-less steel cam style lock mount-edinthedoor.Thecabinetshallbemanufacturedwithacontinu-ous drainage channel which mates with a teardrop shaped, hollow center, watertight, thermo-plasticdoorseal.Thebottomofthecabinetshallbeprepunchedforelectricalconduit.Theabove
5. Water service inlet piping6. Water service outlet piping7. Finish grade8. Enclosure Foot
Thepumpenclosureshallbeofavandal and weather resistant nature manufactured entirely of marine grade aluminum alloy 5052-H32,withawallthicknessof one eighth inch. The mounting baseshallbemanufacturedentirely of stainless steel. The mainhousingshallbeofsolidsheet construction punched on the ends with louvers for ventila-tion.Theenclosureshallbeacenter split design, having mounting lips on each end. The mountingbaseshallbesub-merged into the concrete a mini-
mum of two inches, positioning the enclosure two and one half inchesabovetheconcretefordrainage purposes. The locking mechanismshallbeofthefullrelease type which allows for complete removal of the enclo-surefromitsmountingbasewith-out the use of tools. The locking mechanismshallbeaStainlessSteel Cross Bar style and provide for a padlock.
48
ALuMInuMEnCLOSurE
Thebackflowenclosureshallbeof a vandal resistant nature man-ufactured entirely of marine gradealuminumalloy5052-H32,with a wall thickness of one eighthinch.Themountingbaseplateshallbemanufacturedofstainless steel and powder coat-ed.Themainhousingshallbeofsolid sheet construction with stainlesscarriageboltsusedforassemblingenclosuresidestop
and ends. The enclosure shall have a drop down door with stainless hardware hidden beneathdoorframe.Theenclo-surebodyshallliftopen,pivotingfromthebackedgemountedtobasealsowithhiddenstainlesshardware. Enclosure shall stay securedtomountingbaseplatein open and closed positions. Mounting Base shall have con-creteanchorboltstosubmerge
into concrete leaving mounting baseflushonconcretesurface.The enclosure door shall have a recessed handle and provide a concealed hasp for a padlock.
1. Aluminum Backflow Enclosure2. Backflow Preventer3. Framed Mounting Base – powder coated polymer with anchorsinsetforenclosureandanchorboltsforconcrete4. PouredConcreteBase–6”minimumthickness– extend4”beyondoutsidedimensionsofenclosure
5. Water Service Inlet Piping6. Water Service Outlet Piping7. Finish Grade
InSTALLATIOn DETAILS
BACKFLOW EnCLOSurEMODELS: SBBC–22AL, SBBC–30AL,
SBBC–45AL
SPECIFICATIOnS
49
ALuMInuMEnCLOSurE
Thebackflowenclosureshallbeof a vandal and weather resistant nature manufactured entirely of marine grade aluminum alloy 5052-H32,withawallthicknessof one eighth inch. The mounting baseshallbemanufacturedentirely of stainless steel. The mainhousingshallbeofsolidsheet construction punched on the sides with a rectangular pat-
ternforviewingbackflowopera-tion.Theenclosureshallbeacenter split design, having mounting lips on each end. The mountingbaseshallbesub-merged into the concrete a mini-mum of two inches, positioning the enclosure one and one half inchesabovetheconcretefordrainage purposes. The locking mechanismshallbeofthefull
release type which allows for complete removal of the enclo-surefromitsmountingbasewith-out the use of tools. The locking mechanismshallbeaStainlessSteel Cross Bar style and provide for a padlock.
Thebackflowenclosureshallbeof a vandal resistant nature manufactured entirely of marine gradealuminumalloy5052-H32,with a wall thickness of one eighthinch.Themountingbaseplateshallbemanufacturedofstainless steel and powder coat-ed.Themainhousingshallbeofsolid sheet construction with stainlesscarriageboltsusedforassemblingenclosuresidestopand ends. The enclosure shall have a drop down door with stainless hardware hidden
beneathdoorframe.Theenclo-surebodyshallliftopen,pivotingfromthebackedgemountedtobasealsowithhiddenstainlesshardware. Enclosure shall stay securedtomountingbaseplatein open and closed positions. Mounting Base shall have con-creteanchorboltstosubmergeinto concrete leaving mounting baseflushonconcretesurface.The enclosure door shall have a recessed handle and provide a concealed hasp for a padlock.InsulatedPolarBeariersshallbe
usedtoprotectbackflowdevicesfrom freezing temperatures inside StrongboxInsulatedAluminumEnclosures. Polar Beariers pro-tect to a R19 insulation rating using Radiant Barrier Foil (RBF) insertedbetweenacrylicpolyes-terandairbubblepack.Theselayersforminganinsulatedbagshallbeimpervioustomoisture.
1. Aluminum Backflow Enclosure2. Backflow Preventer3. Framed Mounting Base – powder coated polymer with anchorsinsetforenclosureandanchorboltsforconcrete4. PouredConcreteBase–6”minimumthickness– extend4”beyondoutsidedimensionsofenclosure
5. Water Service Inlet Piping6. Water Service Outlet Piping7. Finish Grade
InSTALLATIOn DETAILS
SPECIFICATIOnS
BACKFLOW EnCLOSurEMODELS: SBBC–22ALI, SBBC–30ALI,
SBBC–45ALI
51
InSuLATED ALuMInuMEnCLOSurE
Thebackflowenclosureshallbeof a vandal and weather resistant nature manufactured entirely of marine grade aluminum alloy 5052-H32,withawallthicknessof one eighth inch. The mounting baseshallbemanufacturedentirely of stainless steel. The mainhousingshallbeofsolidsheet construction with a R-19 Polar Bearier insulation cover. A flexiblerubberinsertformedinto
a loop to provide dead air space shallbeinstalledalongthebot-tom.Theenclosureshallbeacenter split design, having mounting lips on each end. The mountingbaseshallbesub-merged into the concrete a mini-mum of two inches, positioning the enclosure one and one half inchesabovetheconcretefordrainage purposes. The locking mechanismshallbeofthefull
release type which allows for complete removal of the enclo-surefromitsmountingbasewith-out the use of tools.The locking mechanismshallbeaStainlessSteel Cross Bar style and provide for a padlock.
The Backflow cage enclosure shallbeofavandalresistantnature manufactured of formed stainlesssteeltubingandrod,coated with a performance poly-mer alloy coating. Special pow-dercoatedcolorsavailableasperspecifiedbycity.Alllockingandmountinghardwareshallbemanufactured entirely of stainless steel. The frame of the enclosure shallbeconstructedofoneandonequarterinchtubingasamin-imum, including the drop down door which inserts into the open end of the frame. The top, sides andendpanelsshallbecon-
structed of rod forming a one inchbytwoandahalfinchrect-angular pattern as a maximum opening. The vertical rods shall beaminimumofthreesixteenthsinch thick and the horizontal rods shallbeaminimumofoneeighth.Theserodsshallbeweld-ed together forming grids. These gridsshallbeweldedintothetubeframeshalfinchweldsnotmore than four inches apart. The enclosure door and enclosure shallbecleanedandcoated with not less than three mils powder coat.
Each enclosure shall have a mountingpadwhichshallbeused as installation frame. Enclosure hardware on the mountingframeshallbestainlesssteel.Mountingframeshallbeinstalledusingfoureach,3/8”“L”anchorboltssubmergedincon-crete a minimum two inches. The backflowcageenclosureshallremainboltedtoframeinopenand closed positions. Enclosure and door shall close with con-cealedlockingtabwithsevensix-teenths hole to accept padlock.
5. Enclosure Locking Swing Door (door mounted to anchorbase)6. Padlock Protective Cover7. Enclosure Swivel Point – attached to mounting base.Enclosuresecuredtobase(6places)8. EnclosureMountingBaseStuds.3/8”x3/4”
InSTALLATIOn DETAILS
SPECIFICATIOnS
BACKFLOW COVErMODELS: SBBC–22SS, SBBC–30SS,
SBBC–45SS
53
STAInLESS STEELEnCLOSurE
Thebackflowenclosureshallbeof a vandal resistant nature man-ufactured of formed stainless steeltubingandrodtopreventhandlinginjury.Thelockingmechanism and mounting hard-wareshallbemanufacturedentirely of stainless steel. The frameoftheenclosureshallbeconstructed of one and one quarterinchtubing.Thetopsides,andendpanelsshallbe
constructed of rod welded togetherformingaonebytwoinch rectangular pattern. The ver-ticalrodshallbethreesixteenthsandhorizontalrodshallbeoneeighth inch thick. The SBBC-20SS shall have inner door on one end to provide entry with covered padlock at top of door for security. The SBBC-40SS and SBBC-75SSshallbeclamshelldesign with padlock hasp on to
wheretwopiecesjoinintheclosed position. Enclosure ends shall have a mounting lip on each side which attaches to mounting whichissubmergedintocon-crete.Enclosureshallbeposi-tioned one and one half inches aboveconcretetoallowfordrain-age.Vandalproofbracketsshallbeinstalledduringinstallation.
1. Smooth Touch Backflow Cover2. Backflow Preventer3. Anchor Plates (typical)4. PouredConcreteBase–6”minimum thickness–extend4”beyondoutside dimensions of enclosure5. Water Service Inlet Piping6. Water Service Outlet Piping7. Finish Grade8. RemovableLockingEnd
InSTALLATIOn DETAILS
SPECIFICATIOnS
BACKFLOW COVErMODELS: SBBC–20SS, SBBC–40SS,
SBBC–75SS
SBBC-20SS SBBC-40SS, SBBC-75SS
1. Smooth Touch Backflow Cover2. Backflow Preventer3. Secured Swivel Mounting Plates4. PouredConcreteBase–6”minimumthickness– extend4”beyondoutsidedimensionsofenclosure5. SBBCMountingBase–fastenedoranchorbolted to concrete6. Water Service Outlet Piping7. Water Service Inlet Piping8. PadlockLockingHasp9. Finish Grade
54
POWDEr COATEDEnCLOSurE
The Backflow cage enclosure shallbeofavandalresistantnature manufactured of formed coldrolledsteeltubingandrod,coated with a performance poly-mer alloy coating. Special pow-dercoatedcolorsavailableasperspecifiedbycity.Alllockingandmountinghardwareshallbemanufactured entirely of stainless steel. The frame of the enclosure shallbeconstructedofoneandonequarterinchtubingasamin-imum, including the drop down door which inserts into the open end of the frame. The top, sides andendpanelsshallbecon-structed of rod forming a one
inchbytwoandahalfinchrect-angular pattern as a maximum opening. The vertical rods shall beaminimumofthreesixteenthsinch thick and the horizontal rodsshallbeaminimumofoneeighth.Theserodsshallbeweld-ed together forming grids. These gridsshallbeweldedintothetubeframeshalfinchweldsnotmore than four inches apart. The enclosure door and enclo-sureshallbecleanedandcoatedwith not less than three mils powder coat. Each enclosure shall have a mountingpadwhichshallbe
used as installation frame. Enclosure hardware on the mountingframeshallbe stainless steel. Mounting frame shallbeinstalledusingfoureach,3/8”“L”anchorboltssub-merged in concrete a minimum twoinches.Thebackflowcageenclosureshallremainboltedtoframe in open and closed posi-tions. Enclosure and door shall closewithconcealedlockingtabwith seven sixteenths hole to accept padlock.
1. Smooth Touch Backflow Cover2. Backflow Preventer3. Anchor Base Mount4. PouredConcreteBase–6”minimumthickness– extend4”beyondoutsidedimensionsofenclosure5. Enclosure Locking Swing Door (door mounted to anchorbase)
6. Padlock Protective Cover7. Enclosure Swivel Point – attached to mounting base.Enclosuresecuredtobase(6places)8. EnclosureMountingBaseStudes3/8”x3/4”9. Finish Grade10. Water Service Inlet Piping
InSTALLATIOn DETAILS
SPECIFICATIOnS
BACKFLOW COVErMODELS: SBBC–22Cr, SBBC–30Cr,
SBBC–45Cr
55
POWDEr COATEDEnCLOSurE
Thebackflowenclosureshallbeof a vandal resistant nature man-ufactured of formed cold rolled steeltubingandrodtopreventhandlinginjury.Thelockingmechanism and mounting hard-wareshallbemanufacturedentirely of stainless steel. The frameoftheenclosureshallbeconstructed of one and one quarterinchtubing.Thetopsides,andendpanelsshallbe
constructed of rod welded togetherformingaonebytwoinch rectangular pattern. The ver-ticalrodshallbethreesixteenthsandhorizontalrodshallbeoneeighth inch thick. The SBBC-40CRandSBBC-75CRshallbeclam shell design with padlock haspontowheretwopiecesjoinin the closed position. Enclosure ends shall have a mounting lip on each side which attaches to
mountingwhichissubmergedinto concrete. Enclosure shall bepositionedoneandonehalf inchesaboveconcretetoallowfor drainage. Vandal proof bracketsshallbeinstalled during installation. The cover shallbecoveredwithazincbasepowder coat then powder coated with a polyester TGIC coating having a minimum thickness of 2.5 mils.
6. Water Service Outlet Piping7. Water Service Inlet Piping8. PadlockLockingHasp9. Finish GradeNote:Enclosureshallswiveloutwardtoexposeback-flow.Backflowcoverissecuredtobaseandtoolsmustbeusedtoremovecompletely.
InSTALLATIOn DETAILS
SPECIFICATIOnS
BACKFLOW COVErMODELS: SBBC–40Cr, SBBC–75Cr
56
ExPAnDED METALBACKFLOW COVEr
Thebackflowcovershallbeofavandal resistant nature manufac-tured of formed and expanded metal, coated with a perfor-mance polymer alloy coating to preventhandlinginjury.Thecover shall have a hinge on one endandalockingtabontheotherend.Thehingeshallbeattachedtomountingbracketswithcarriageboltstoallowremoval of the cover from the
hinges.Themountingbracketsshallbesubmergedintothecon-crete a minimum of two inches, positioning the cover one and onehalfinchesabovethecon-crete.Thelockingtabshallacceptapadlock.Handlesshallbeattachedtothesidestofacili-tate raising and lowering of the cover.Thecovershallbecoveredwithazincbasepowdercoatthen
powder coated with a polyester TGIC coating having a minimum thickness of 2.5 mils.
5. Water Service Inlet Pipe6. Water Service Outlet Pipe7. Finish Grade
InSTALLATIOn DETAILS
SPECIFICATIOnS
BACKFLOW COVErMODELS: BC–30Cr, BC–45Cr,
57
ExPAnDED METALBACKFLOW COVEr
Thebackflowcovershallbeofavandal resistant nature manufac-tured of formed and expanded metal, coated with a perfor-mance polymer alloy coating to preventhandlinginjury.Thecovershallbeintwosectionswith a hinge on each end and a lockingtabatthecenter.Thehingesshallbeattachedtomountingbracketswithcarriageboltstoallowremovalofthe
cover from the hinges. The mountingbracketsshallbesub-merged into the concrete a mini-mum of two inches, positioning the cover one and one half inch-esabovetheconcrete.Thelock-ingtabshallacceptapadlock.Handlesshallbeattachedtothesides to facilitate raising and lowering of the cover.Thecovershallbecoveredwithazincbasepowdercoatthen
powder coated with a polyester TGIC coating having a minimum thickness of 2.5 mils.
The metered controller enclosure shallbeadoubledoordesignpositionedfrontandback,vandaland weather resistant, manufac-tured entirely of stainless steel. The front section shall house a UL listed, E.U.S.E.R.C. approved 100 Amp rated commercial meter socketwithtestblockbypassprovision.Thebacksectionshallbelouveredupperandlowerbodytoallowforcrossflowventi-lation. Filter screens shall cover all louvers to deflect against water spray, insects and dust. Thebacksectionshallhavea
stainlesssteelbackboardprovid-ed for the purpose of mounting a controller.Thebackboardshallbemountedonfourstainlesssteelboltsthatwillallowforremovalofthebackboard.Theinside door area shall provide adequatestorageforplans,operating instructions and scheduling information. The enclosure shall have continuous stainless steel piano hinges on one side of each door. The edge ofthedoorshallbehemmedtoeliminate any sharp edges. The handles controlling the locking
mechanismsshallbelocatedatthebaseofthedoorsandbeconcealed within the surface of the doors. The provision for pad-locksshallbeincludedwithinthelocking mechanisms. The enclo-sureshallbemanufacturedwitha continuous drainage channel which mates with a tear-drop shaped, hollow center, water-tight, thermoplastic door seal. TheabovedescribedproductshallbeaNEMATYPE3RRainproofenclosureaslistedbyUnderwriterLaboratories,Inc.
1. Metered controller enclosure2. Metersocketwithtestblocks3. Load center4. Conduit (not supplied) for line feed into meter5. Pouredconcretebase—6"min.thickness—extend6" beyondoutsidedimensionsofenclosurewith1/2%slope for drainage
6. Finish grade7. Directburialcontrolwirestocontrolvalves8. PVC long sweep ell—use one sweep ell per controller9. Automatic controller
InSTALLATIOn DETAILS
SPECIFICATIOnS
59
100 AMPMODELS: MPS-A16, MPS-B16, MPS-D18
InSTALLATIOn DETAILS
Themeterpedestalshallbemadeentirely of stainless steel, #4 brushedfinish,utilizingallweldedconstruction providing superior van-dal and weather resistance.Thetopshallbeasideswingstylethat locks out for safety. The side swing top shall fully expose the meter compartment for ease of set-ting the meter and access to the testblocks.Thetopshallbesup-portedby3largeallstainlesssteelhingeswith1/4”pinsthatare“liftoff”styleallowingthetoptobecompletelyremoved.Areplaceable5”x10”,3/16”thickLexanviewingwindowshallbeprovided.Themetersockettestblockcom-partmentshallbeequippedwithawatershed drainage channel and
overlappingequipmentpanelsthatensures a watertight design. Within the top meter compartment the metersockettestblockassemblyshallbeinstalled.Thetopshallbecompletelypadlockableandaccepta utility seal.Theutilitycompartmentshallbelocated on the right side and house the landing lugs. A cover panel that can accommodate a padlock and utilitysealshallbeprovided.The left side of the pedestal shall housethe20”x30”customerelec-trical compartment. This compart-mentshallbeoutfittedwithafullywelded and hemmed stainless steel gasketed door that closes against a watershed drainage channel. The door design and all stainless steel
T handle latching system shall ensure water tightness and vandal resistance.The interior portion of this compart-ment shall house up to a 20 circuit capableloadcenterwitharemov-ableprotectivepanel.Astainlesssteelelectricalbackboardshall beprovidedforeaseofwiring and grounding of electrical components.Thepedestalassemblyshallbeasingle phase or three phase, 120V/240V or 480V rated unit. TheenclosureshallberainproofNEMATYPE3RandtheassemblyshallbelistedbyUnderwriterLaboratories,Inc.forserviceentranceequipment.
SPECIFICATIOnSThemeterpedestalshallbemadeentirely of stainless steel, #4 brushedfinish,utilizingallweldedconstruction providing superior vandal and weather resistance.Thetopshallbeasideswingstylethat locks out for safety. The side swing top shall fully expose the meter compartment for ease of set-ting the meter and access to the testblocks.Thetopshallbesup-portedby3largeallstainlesssteelhingeswith1/4”pinsthatare“liftoff”styleallowingthetoptobecompletelyremoved.Areplaceable5”x10”,3/16”thickLexanviewingwindowshallbeprovided.Themetersockettestblockcom-partmentshallbeequippedwithawatershed drainage channel and
overlappingequipmentpanelsthatensures a watertight design. Within the top meter compartment the metersockettestblockassemblyshallbeinstalled.Thetopshallbecompletelypadlockableandaccept a utility seal.Theutilitycompartmentshallbelocated on the right side and house the landing lugs. A cover panel that can accommodate a padlock and utilitysealshallbeprovided.The left side of the pedestal shall housethe20”x30”customerelec-trical compartment. This compart-mentshallbeoutfittedwithafullywelded and hemmed stainless steel gasketed door that closes against a watershed drainage channel. The door design and all
stainless steel T handle latching system shall ensure water tightness and vandal resistance.The interior portion of this compartment shall house up to a 20circuitcapableloadcenterwitharemovableprotectivepanel.Astainlesssteelelectricalbackboardshallbeprovidedforeaseof wiring and grounding of electrical components.Thepedestalassemblyshallbeasingle phase or three phase, 120V/240V or 480V rated unit. TheenclosureshallberainproofNEMATYPE3RandtheassemblyshallbelistedbyUnderwriterLaboratories,Inc.forserviceentranceequipment.
8. Pouredconcretebase—6"min.thickness—extend6" beyondoutsidedimensionsofenclosurewith1/2% slope for drainage9. Finish grade10. Underground service11.Meterviewingwindow5”x10”12.3/8”stainlessanchorbolts
61
STAInLESS STEELMETEr PEDESTAL WITH EnCLOSurE
100 AMPMODELS: MPE-A16, MPE-B16, MPE-D18
Themeterpedestalshallbemadeentire-lyofstainlesssteel,#4brushedfin-ish, utilizing all welded construction providing superior vandal and weath-er resistance.Thetopshallbeasideswingstylethat locks out for safety. The side swing top shall fully expose the meter compartment for ease of setting the meterandaccesstothetestblocks.Thetopshallbesupportedby3largeallstainlesssteelhingeswith1/4”pinsthatare“liftoff”styleallowing thetoptobecompletelyremoved. Areplaceable5”x10”,3/16”thickLexan viewing window shall beprovided.Themetersockettestblockcompart-mentshallbeequippedwithawater-shed drainage channel and overlap-pingequipmentpanelsthatensuresa
watertight design. Within the top meter compartment the meter socket testblockassemblyshallbeinstalled.Thetopshallbecompletelypadlock-ableandacceptautilityseal.Theutilitycompartmentshallbelocat-ed on the right side and house the landing lugs. A cover panel that can accommodate a padlock and utility sealshallbeprovided.The left side of the pedestal shall housethe20”x30”customerelectri-cal compartment. This compartment shallbeoutfittedwithafullyweldedand hemmed stainless steel gasketed door that closes against a watershed drainage channel. The door design and all stainless steel T handle latch-ing system shall ensure water tight-ness and vandal resistance.The interior portion of this compart-
ment shall house up to a 20 circuit capableloadcenterwitharemovableprotective panel. A stainless steel electricalbackboardshallbeprovid-ed for ease of wiring and grounding of electrical components.Thepedestalassemblyshallbeasin-gle phase or three phase, 120V/240V or 480V rated unit. The enclosure shallberainproofNEMATYPE3RandtheassemblyshallbeULlistedforserviceentranceequipment.Theenclosuresectionshallbeofavandal and weather resistant nature manufactured entirely of stainless steel.Themainhousingshallbelou-veredupperandlowerbodytoallowfor cross flow ventilation. Filter screens shall cover all louvers to deflect against water spray, insects and dust. Astainlesssteelbackboardshallbeprovided for the purpose of mounting electronic and various other types of equipment.Thebackboardshallbemountedonsixstainlesssteelboltsthatwillallowforremovaloftheback-board.Theinsidedoorareashall provideadequatestorageforplans,operating instructions, and schedul-ing information. The enclosure door shall have a con-tinuous stainless steel piano hinge, carriageboltedononeside,andathree point locking mechanism on the other side. The edge of the door shall behemmedtoeliminateanysharpedges. The handle controlling the lockingmechanismshallbelocatedatthebaseofthedoorandbecon-cealed within the surface of the door. A stainless steel cam style lock shall bemountedinthedoorandaprovi-sionforapadlockshallbeincludedwithin the locking mechanism. The enclosureshallbemanufacturedwitha continuous drainage channel which mates with a teardrop shaped, hollow center, watertight, thermoplastic door seal. Theabovedescribedproduct shallbeaNEMA3RRainproof EnclosureaslistedbyUnderwriterLaboratories,Inc.
Themeterpedestalshallbemadeentirelyofstainlesssteel,#4brushedfinish, utilizing all welded construction providing superior vandal and weather resistance.Thetopshallbeasideswingstylethat locks out for safety. The side swing top shall fully expose the meter compartment for ease of setting the meterandaccesstothetestblocks.Thetopshallbesupportedby3largeallstainlesssteelhingeswith1/4”pinsthatare“liftoff”styleallowing thetoptobecompletelyremoved. Areplaceable5”x10”,3/16”thickLexan viewing window shall beprovided.Themetersockettestblockcompart-mentshallbeequippedwithawater-shed drainage channel and overlap-pingequipmentpanelsthatensuresa
watertight design. Within the top meter compartment the meter socket testblockassemblyshallbeinstalled.Thetopshallbecompletelypadlock-ableandacceptautilityseal.Theutilitycompartmentshallbelocat-ed on the right side and house the landing lugs. A cover panel that can accommodate a padlock and utility sealshallbeprovided.The left side of the pedestal shall housethe20”x30”customerelectri-cal compartment. This compartment shallbeoutfittedwithafullyweldedand hemmed stainless steel gasketed door that closes against a watershed drainage channel. The door design and all stainless steel T handle latch-ing system shall ensure water tight-ness and vandal resistance.The interior portion of this compart-
ment shall house up to a 20 circuit capableloadcenterwitharemovableprotective panel. A stainless steel electricalbackboardshallbeprovid-ed for ease of wiring and grounding of electrical components.Thepedestalassemblyshallbeasin-gle phase or three phase, 120V/240V or 480V rated unit. The enclosure shallberainproofNEMATYPE3RandtheassemblyshallbeULlistedforserviceentranceequipment.Theenclosuresectionshallbeofavandal and weather resistant nature manufactured entirely of stainless steel.Themainhousingshallbelou-veredupperandlowerbodytoallowfor cross flow ventilation. Filter screens shall cover all louvers to deflect against water spray, insects and dust. Astainlesssteelbackboardshallbeprovided for the purpose of mounting electronic and various other types of equipment.Thebackboardshallbemountedonsixstainlesssteelboltsthatwillallowforremovaloftheback-board.Theinsidedoorareashallpro-videadequatestorageforplans,operating instructions, and schedul-ing information. The enclosure door shall have a con-tinuous stainless steel piano hinge, carriageboltedononeside,andathree point locking mechanism on the other side. The edge of the door shall behemmedtoeliminateanysharpedges. The handle controlling the lockingmechanismshallbelocatedatthebaseofthedoorandbecon-cealed within the surface of the door. A stainless steel cam style lock shall bemountedinthedoorandaprovi-sionforapadlockshallbeincludedwithin the locking mechanism. The enclosureshallbemanufacturedwitha continuous drainage channel which mates with a teardrop shaped, hollow center, watertight, thermoplastic door seal. TheabovedescribedproductshallbeaNEMATYPE3RRainproofEnclosureaslistedbyUnderwriterLaboratories,Inc.
Themeterpedestalshallbemade entirely of stainless steel, using welded construction and finishing.Pedestalsshallbecoveredbypolyester TGIC powder coating having a minimum thickness of 2.5 mils.Topcovershallbeasideswingstyle that locks out for safety. The swing top will open 180 degrees to provide clear access to meter socketandtestblocks.Theswingtopshallbesupportedbytwo heavy duty stainless steel hingeswith3/8”pinsandthatare“liftoff”styleallowingthetoptobecompletelyremoved.The
Swing top shall also have hemmed edges to eliminate sharpedges.Areplaceable3/16”thicklexanwindowforviewingshallbeinstalledformeter reading. Lexan window shallbehingedandavailablewith hasps to lock out for safety.Themetersocketandtestblocksectionshallbeequippedwithrainwater drainage channel and overlappingequipmentpanelstoensure watertight design. The meter socket compartment shall house EUSERC approved com-mercial meter socket and test blocks.Themetersectionshallaccept ring style meter and
meterfacebeattachedtometersocket so meter face panel may notberemovedwithoutdiscon-nectingmeterbulb.Metersec-tionmustbepadlockableforsafety as well as utility seal.The Utility landing section shall betherearwitharemoveablepanel for full access to landing lugs.Landinglugsshallbealu-minum type lugs using hexagon screws for tightening.A cover panel that will accommo-date a padlock and utility seal shallbeprovided.Thecustomersectionwillbeinthe lower front of the pedestal. Thecompartmentshallbefittedwith a fully welded door with hemmed edges to eliminate sharp edges. The door design shall use a T-handle latching system to ensure a watertight seal and vandal resistance. A continuouspianohingeshallbeused and installed using carriagebolts.This compartment will house a GEloadcenterwithmainbreak-er.theinternalhousingwillbe fitted with a protective panel and shall only expose the breakerswitches.Themeterpedestalassembliesshallbe0-200Amp,singlephaseonly 120V/240V rated. The encl sure shall comply with EUSERC electrical standards and current NECcodes.TheenclosureshallberatedNEMATYPE3Rrain-proofandbelistedbyUnderwriterLaboratories,Inc.
TreetiesshallbemanufacturedofvirginflexiblevinylmeetingASTM-D-412 standards for tensile and elongation strength. Materialshallbeblackforultravi-oletresistance.Treetiesshallbemanufacturedwithadoublebacklocking configuration and secured with one galvanized nail to prevent slippage. Tree ties shall elongate with the tree growth preventing damage to the tree.
HOW TO uSE CInCH-TIESSingle StakeAsinglestakeshouldbeplacedonthesideoftheprevailingwind.ThetreeshouldbesupportedwithaminimumoftwoCinch-Ties.Useeither the Standard or Figure Eight tying method.
Double StakesOnestakeshouldbeplacedonthesideoftheprevailingwindwiththeotherstakeontheoppositesideofthetree.Thetreeshouldbesupported with four Cinch-Ties to assure a straight, firm position. Use either the Standard or Figure Eight tying method.
Standard TieWrap Cinch-Tie around the tree trunk and the stake to form a loop. Tie withthedouble-backlockingconfiguration.Securewithagalvanizednail driven through the Cinch-Tie and into the stake to prevent slip-page.
Figure Eight TieWrap Cinch-Tie around the tree trunk and the stake twisting to form a figureeight.Tiewiththedouble-backlockingconfiguration.Securewith a galvanized nail driven through the Cinch-Tie and into the stake to prevent slippage.
Location GuidelineStep 1. Cut the nursery provided supports away from the young tree.Step2.Todeterminethebestplace to install Cinch-Tie, hold the tree trunk at different points to find the spot where the top doesnotbendover.Install theCinch-Tie6”tallerthan this height.
Step 3. The first Cinch-Tie should beplaced6”higherthanthespot on the trunk where your hand previously determined sup-port for the top.Step4.Treesshouldbesecuredwith at least two Cinch-Ties to assure a straight, firm hold.
SPECIFICATIOnS
65
TrEE & SPrInKLEr SuPPOrTAnD PrOTECTIOn PrODuCTS
CInCH-BELT™
Thetreetiesshallbemanufac-turedofvirginflexiblevinylmeet-ing ASTM-D412 standards for tensile and elongation strength. Materialshallbeblackforultravi-oletresistance.Treetiesshallbemanufactured with a rounded backsidetoprotectthetreeandlockedintopositionwithabuckle.
SPECIFICATIOnSThetreetieshallbesecuredtoawooden post with one galvanized nail,ordoublewrappedaroundametal post to prevent slippage. Tree ties shall elongate with the tree growth preventing damage to the tree.
HOW TO uSE CInCH-BELTSingle StakeAsinglestakeshouldbeplacedonthesideoftheprevailingwind.ThetreeshouldbesupportedwithaminimumoftwoCinch-Belts.Useeither the Standard or Figure Eight tying method.
Double StakesOnestakeshouldbeplacedonthesideoftheprevailingwindwiththeotherstakeontheoppositesideofthetree.Thetreeshouldbesupported with four Cinch-Belts to assure a straight, firm position. Use either the Standard or Figure Eight tying method.
Standard TieWrap Cinch-Belt around the tree trunk and the stake to form a loop. Insert bothendsofCinch-Beltthroughbuckle.Securewithasgalvanizednaildriven through the Cinch-Belt and into the stake to prevent slippage.
Figure Eight TieWrap Cinch-Belt around the tree trunk and the stake twisting to form a figureeight.InsertbothendsofCinch-Beltthroughbuckle.Securewith a galvanized nail driven through the Cinch-Belt and into the stake to prevent slippage.
Metal Stake TieWrapCinch-Beltaroundthetreetrunkanddouble-wrapthestaketopreventslippage.InsertbothendsofCinch-Beltthroughbuckle.
Bolt Style is designed for through pole installation using either galvanized pipe or lodge pole pines. Threaded ends are insertedthroughdrilledholesandboltedsecurely. (TB 36, TB 42)
Pole
GalvanizedNails
Flat Washer
NutLock
Washer
Lock Washer
NutFlat Washer
Model loop dia. overall length SuggeSted for: SuggeSted pole TB24 4-1/2" 24" 5-15gal.–24"boxtrees 2"x10’ TB36 4-1/2" 36 24"–30"boxtrees 2"x10’
The5/16"roundmetalrodshallbeencasedinblackU.V.resis-tantvinyltubingplacedatthecenteroftherod.The5/16"rodistobebentina360°circle.Themeetingpointsoftherodshallbespread apart permitting the
The1/2"roundthreadedmetalrodshallbeencasedinblackU.V.resistantvinyltubingplacedat the center of the rod. The rod istobebentina360°circle.Themeetingpointsoftherodshallbespread apart permitting the
bracetobeplacedonthetreebyholdingitparalleltothetreetrunk with the open part of the circle on either side of the trunk. Thetreetrunkshallbeenclosedinthecircleasthebraceistwist-ed at right angles to the trunk.
Mounting plates with nail holes foreithersquareorroundstakes,shallbeweldedateachendofthe rod. Exposed metal ends shallbetreatedwitharust inhibitingcoating.
SPECIFICATIOnS–BOLT STYLEbracetobeplacedonthetreebyholdingitparalleltothetreetrunk with the open part of the circle on either side of the trunk. Thetreetrunkshallbeenclosedinthecircleasthebraceistwist-
ed at right angles to the trunk. Thethreadedendsshallbeinserted through drilled holes in the stakes or poles and secured with nuts, lock washers and flat washers.
InSTALLATIOn DETAILSNOTES:• Stakealltrees24”boxand smaller. Install V.I.T. Products Model TG-4 Trim Guard on all trees planted in turf.• Refertospecificationsforplant pit size.• InstallTwist-Braceper manufacturer’s recommenda tions.1. V.I.T. Twist Brace–secure to each pole2. 2”dia.lodgepolepinetreestake3. Depressedwateringbasin remove from turf areas during finish grading4. Finish grade5. Backfill mix per specs.6. Plant packets per specs.7. Compactedbackfillmixper specs.8. Tree
Pipe Stabilizer-Usedinbetweensprinkler heads to control move-ment of the pipe. The vertical striking area provides good pen-etration in even the toughest soils andminimizestheabovegroundexposure. Since the hammer only touches the vertical metal the rounded J hook is untouched and damage is avoided. Vinyl covered J hooks shall protect the pipe from damage.Sprinkler Stabilizer- Used to
secure pipe and sprinkler heads to prevent movement, vandalism and damage. The vertical metal providesareatodrivethestabi-lizer into the soil. The vinyl cov-ered J hooks secure the pipe to the ground while the steel shaft at the top gives the sprinkler head additional support.Sprinkler Ties- Used to secure the sprinkler to the Sprinkler Stabilizer.Theuniquedesignallows fast installation while pro-ducingastrongbondbetweenthe stake and the sprinkler head.
The stainless steel wire and the vinyl covering produces a secure solution to attaching sprinklers to the stakes.Ratchet Tool- Installation tool pro-viding a solid grip. Attach the Ratchet Tool hook into the eyelets of the Sprinkler Tie and pull back.Thetwistingactionisuniquetothetool.Thissecuresthe sprinkler against the stake. The Ratchet Tool is designed to spin wires to tighten.
LIMITEDTrADE WArrAnTIES
Stainless ProductsV.I.T. Products, Inc. warrants to its trade customers that its Strong Box®productswillbe free fromoriginaldefects in materials and workmanship for a period of ten years from the original date of purchase. It will repair or replaceat itsdiscretion,parts found tobedefectiveundernormaluseandservicewithin thewarrantyperiod,uponreturnofsuchpartsatthetradecustomer’sexpense.V.I.T.Products,Inc.willnotberesponsibleforincidentalorconsequentialdamagesorforproductswhichhavebeenalteredormodifiedanditsliabilityunderthiswarrantyislimitedsolelytoreplacementorrepairofdefectiveparts.Noagentorrepresentativehas authority to waive, alter, or add to the printed provisions of this warranty, to make any representation or warranty not contained herein or to extend this warranty to anyone other than the Strong Box® customer. This warrantyisgivenexpresslyandinplaceofallotherexpressedorimpliedwarrantiesofmerchantabilityandfitness for particular purpose and this warranty is the only warranty made by V.I.T. Products, Inc. V.I.T.Products,Inc.cannotanddoesnotassumeliabilityfordefectiveproducts,ordamagecausedbydefectiveproducts,notmanufacturedorsuppliedbyit,eventhoughsuchproductsbeusedinconjunctionwithStrongBox® products. V.I.T. Products, Inc. reserves the right to redesign, alter or modify its products without incurring anyliabilityfromanyone’sinventoryofsuchpartsorproductsthatmaybeobsolete.
Cold rolled Steel ProductsV.I.T. Products, Inc. warrants to its trade customers that its Strong Box®productswillbe free fromoriginaldefects in materials and workmanship for a period of one year from the original date of purchase. It will repair or replaceat itsdiscretion,parts found tobedefectiveundernormaluseandservicewithin thewarrantyperiod,uponreturnofsuchpartsatthetradecustomer’sexpense.V.I.T.Products,Inc.willnotberesponsibleforincidentalorconsequentialdamagesorforproductswhichhavebeenalteredormodifiedanditsliabilityunderthiswarrantyislimitedsolelytoreplacementorrepairofdefectiveparts.Noagentorrepresentativehas authority to waive, alter, or add to the printed provisions of this warranty, to make any representation or warranty not contained herein or to extend this warranty to anyone other than the Strong Box® customer. This warrantyisgivenexpresslyandinplaceofallotherexpressedorimpliedwarrantiesofmerchantabilityandfitness for particular purpose and this warranty is the only warranty made by V.I.T. Products, Inc. V.I.T.Products,Inc.cannotanddoesnotassumeliabilityfordefectiveproducts,ordamagecausedbydefectiveproducts,notmanufacturedorsuppliedbyit,eventhoughsuchproductsbeusedinconjunctionwithStrongBox® products. V.I.T. Products, Inc. reserves the right to redesign, alter or modify its products without incurring anyliabilityfromanyone’sinventoryofsuchpartsorproductsthatmaybeobsolete.
Aluminum ProductsV.I.T. Products, Inc. warrants to its trade customers that its Strong Box®productswillbe free fromoriginaldefects in materials and workmanship for a period of five years from the original date of purchase. It will repair or replaceat itsdiscretion,parts found tobedefectiveundernormaluseandservicewithin thewarrantyperiod,uponreturnofsuchpartsatthetradecustomer’sexpense.V.I.T.Products,Inc.willnotberesponsibleforincidentalorconsequentialdamagesorforproductswhichhavebeenalteredormodifiedanditsliabilityunderthiswarrantyislimitedsolelytoreplacementorrepairofdefectiveparts.Noagentorrepresentativehas authority to waive, alter, or add to the printed provisions of this warranty, to make any representation or warranty not contained herein or to extend this warranty to anyone other than the Strong Box® customer. This warrantyisgivenexpresslyandinplaceofallotherexpressedorimpliedwarrantiesofmerchantabilityandfitness for particular purpose and this warranty is the only warranty made by V.I.T. Products, Inc. V.I.T.Products,Inc.cannotanddoesnotassumeliabilityfordefectiveproducts,ordamagecausedbydefectiveproducts,notmanufacturedorsuppliedbyit,eventhoughsuchproductsbeusedinconjunctionwithStrongBox® products. V.I.T. Products, Inc. reserves the right to redesign, alter or modify its products without incurring anyliabilityfromanyone’sinventoryofsuchpartsorproductsthatmaybeobsolete.
At V.I.T. Products we are committed to manufacturing thefinestqualityproductsavailable.Wecontinuallyevaluateandupgradeourequipmentandmanufac-turingtechniquessowecanofferyouenclosureswith superior fit and finish every time. For example, our computer controlled Strippit LVD 4000 watt laser can cut parts with tolerances as close as .003 of an inch, so each one fits perfectly. And that’s not all. Superiorqualitycontrolisevidentthroughoutthemanufacturingandassemblyprocess.Theendresult is a product we are proud to manufacture in the U.S.A., and one that will give you outstanding performanceanddurabilityformanyyears.