Top Banner
Photo courtesy of Cruisers Yachts Stowaway Turbo Self-Contained Series Powerful, Quiet & Compact With No Drain Pan Worries STQ14K StowAway Turbo shown with optional Sound Shield ISO 9001:2008 L–2502B Rev. 20100122 Customer comment: “There is very little noise coming from the compressor, and vibrations are practically non-existent. I highly recommend this unit.” — Bob Silverman, owner, 305 Bayliner Express Cruiser The Stowaway Turbo series completely revolutionized self-contained cooling and heating with the newest innovations in marine air conditioning system design. The rust-free molded composite drain pan has three drains for the rapid removal of condensate water. The drain pan’s sloped channels route condensate rapidly to a choice of three easy-to-plumb drain locations. An advanced cushioning system results in quieter, virtually vibration-free operation. The enclosed blower motor eliminates overhang to provide easier installation. The high-velocity flower can be rotated 270 degrees with one adjustment screw. The unit’s unique inlet ring is designed to optimize air flow and ensure that the height of the unit does not increase when the blower rotates. Easy-to-install sound cover provides up to 50% noise reduction These compact, easy-to-install sound covers are available for all Stowaway Turbo models. The cover fits over the compressor, providing a 3- to 5-dB noise reduction—which is about a 50% drop in what the human ear can perceive. Installation takes just minutes and all mounting hardware is included. Key Benefits Up to 27% more energy efficient. Up to 21% increased capacity. Compact design uses less space. Rust-free drain pan. Up to 85% less standing water in drain pan. Reduced noise and vibration with high- velocity blowers and mounts. Optional sound cover further reduces compressor noise by up to 50%.
2

Stowaway Turbo Self-Contained Series - Cruisair … · Stowaway Turbo Self-Contained Series Powerful ... from the compressor ... Circuit Breaker (Amps) 15.0 9.0 21.0 10.0 13.0 25.0

Apr 04, 2018

Download

Documents

duongtram
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Stowaway Turbo Self-Contained Series - Cruisair … · Stowaway Turbo Self-Contained Series Powerful ... from the compressor ... Circuit Breaker (Amps) 15.0 9.0 21.0 10.0 13.0 25.0

Pho

to c

ourt

esy

of C

ruis

ers

Yac

hts

Stowaway Turbo Self-Contained Series Powerful,Quiet&Compact

WithNoDrainPanWorries

STQ14K StowAway Turbo shown with optional Sound Shield

ISO 9001:2008

L–2502B Rev. 20100122

Customer comment:

“Thereisverylittlenoisecomingfromthecompressor,andvibrationsarepracticallynon-existent.Ihighlyrecommendthisunit.”

— Bob Silverman, owner,305 Bayliner Express Cruiser

The Stowaway Turbo series completely revolutionized

self-contained cooling and heating withthenewestinnovationsin

marineairconditioningsystemdesign.

Therust-freemoldedcompositedrainpanhasthreedrainsfortherapidremoval

ofcondensatewater.Thedrainpan’sslopedchannelsroutecondensaterapidly

toachoiceofthreeeasy-to-plumbdrainlocations.

Anadvancedcushioningsystemresultsinquieter,virtuallyvibration-free

operation.Theenclosedblowermotoreliminatesoverhangtoprovideeasier

installation.Thehigh-velocityflowercanberotated270degreeswithone

adjustmentscrew.Theunit’suniqueinletringisdesignedtooptimizeairflowand

ensurethattheheightoftheunitdoesnotincreasewhentheblowerrotates.

Easy-to-install sound cover provides up to 50% noise reduction

Thesecompact,easy-to-installsoundcoversareavailable

forallStowawayTurbomodels.Thecoverfitsoverthe

compressor,providinga3-to5-dBnoisereduction—which

isabouta50%dropinwhatthehumanearcanperceive.

Installationtakesjustminutesandallmountinghardwareis

included.

Key Benefits

■ Up to 27% more energy efficient.

■ Up to 21% increased capacity.

■ Compact design uses less space.

■ Rust-free drain pan.

■ Up to 85% less standing water in drain pan.

■ Reduced noise and vibration with high-velocity blowers and mounts.

■ Optional sound cover further reduces compressor noise by up to 50%.

Page 2: Stowaway Turbo Self-Contained Series - Cruisair … · Stowaway Turbo Self-Contained Series Powerful ... from the compressor ... Circuit Breaker (Amps) 15.0 9.0 21.0 10.0 13.0 25.0

DO

ME

TIC

MA

RIN

E20

00

N. A

ndre

ws

Ave

. Ext

. l P

ompa

no B

each

, FL

33

06

9 U

SA

l 9

54

-973

-247

7 l

Fa

x 95

4-9

79-4

414

ww

w.D

omet

icU

SA

.com

l M

arin

eSal

es@

Dom

etic

US

A.c

om

Un

ite

d S

tate

s &

Ca

na

da

Te

ch

Su

pp

ort

8:

00 AM

to 5

:00

PM

Eas

tern

Tim

e: 8

00

-542

-247

7A

fter

hou

rs a

nd w

eeke

nds:

88

8-4

40-4

494

Inte

rna

tio

na

l S

ale

s &

Se

rvic

e:

Eur

ope

& th

e M

iddl

e E

ast:

Cal

l +4

4(0)

870

-33

0-6

101

For

all

othe

r ar

eas

visi

t our

web

site

to fi

nd y

our

near

est d

istr

ibut

or.

L–25

02B

R

ev. 2

010

0122

S

peci

ficat

ions

sub

ject

to c

hang

e w

ithou

t not

ice.

Deale

r:

Envir

onm

enta

llyRe

spon

sibl

e

Tec

hn

ica

lSp

ec

ific

atio

ns

for

Sto

wa

wa

yTu

rbo

Mod

el(1

)ST

Q6ST

Q8ST

Q10

STQ1

2ST

Q14

STQ1

6

Capa

city

(BTU

/Hr)(2

)6,

000

8,00

010

,000

12,0

0014

,000

16,0

00

Volta

ge (V

AC)(2

)11

522

0-24

011

523

022

0-24

011

523

022

0-24

011

523

022

0-24

011

523

022

0-24

011

523

022

0-24

0

Cycl

e (H

z)/P

hase

(Ph)

(3)

601

501

601

601

501

601

601

501

601

601

501

601

601

501

601

601

501

Full

Load

Am

ps (F

LA) c

ool

3.8

2.1

5.4

2.6

3.6

6.0

3.1

3.4

6.8

3.4

3.7

7.8

4.2

4.4

9.4

4.6

4.5

Full

Load

Am

ps (F

LA) h

eat

5.0

2.8

7.0

3.4

4.4

8.3

4.2

4.3

9.4

4.7

4.7

11.3

5.4

5.8

12.4

6.2

5.8

Lock

ed R

otor

Am

ps (C

omp)

29.0

11.0

40.0

19.0

20.0

42.0

21.0

16.9

53.0

26.0

22.2

58.0

33.0

22.0

59.0

34.0

32.0

K.V.

A. (K

ilo-V

olt-

Amps

)0.

60.

70.

80.

81.

11.

01.

01.

01.

11.

11.

11.

31.

31.

41.

41.

41.

4

Max

. Circ

uit B

reak

er (A

mps

)15

.09.

021

.010

.013

.025

.014

.013

.031

.015

.015

.033

.018

.018

.040

.021

.019

.0

Min

. Circ

uit A

mpa

city

(Am

ps)

9.0

5.0

12.0

6.0

8.0

14.0

8.0

8.0

17.0

9.0

8.0

19.0

10.0

10.0

23.0

12.0

11.0

Refri

gera

nt R

-417

A (o

z/g)

822

78

227

1028

310

283

1028

310

.529

810

.529

810

.529

811

312

1131

211

312

1336

913

369

1336

913

369

1336

913

369

Unit

Dim

ensi

ons

(in/m

m)(4

)

Heig

ht –

Eva

pora

tor (

C† )10

.8/2

7410

.8/2

7412

.2/3

1012

.2/3

1012

.9/3

2812

.9/3

28

Heig

ht –

Com

pres

sor (

D† )12

.2/3

1012

.2/3

1013

.0/3

2914

.2/3

6113

.9/3

5412

.8/3

2513

.9/3

5414

.2/3

6113

.1/3

3214

.3/3

6313

.7/3

48

Heig

ht –

w/o

pt. S

ound

Cov

er13

.0/3

3013

.0/3

3013

.5/3

4315

.0/3

8115

.0/3

8113

.5/3

4314

.5/3

6815

.0/3

8114

.5/3

6815

.0/3

8114

.5/3

68

Wid

th (A

† )17

.6/4

4717

.6/4

4720

.4/5

1820

.4/5

1821

.4/5

4421

.4/5

44

Dept

h (B

† )10

.7/2

7210

.7/2

7212

.4/3

1512

.4/3

1513

.3/3

3813

.3/3

38

Min

. Duc

t Siz

e Ø

(in/m

m)

4/10

25/

127

6/15

26/

152

7/17

87/

178

Min

. SA

Grill

e (s

q. in

./sq.

cm

.)32

/813

48/3

1060

/387

70/4

5276

/490

80/5

23

Min

. RA

Grill

e (s

q. in

./sq.

cm

.)64

/162

680

/516

100/

710

130/

839

144/

929

160/

1032

Net W

eigh

t (lb

s/kg

)39

.6/1

8.0

40.4

/18.

343

.8/1

9.9

43.6

/19.

843

.0/1

9.5

48.8

/22.

152

.8/2

4.0

54.4

/24.

755

.0/2

4.9

53.4

/24.

260

.2/2

7.3

61.2

/27.

859

.8/2

7.1

59.4

/26.

960

.8/2

7.6

63.4

/28.

8

Gros

s W

eigh

t (lb

s/kg

)49

.6/2

2.5

50.4

/22.

953

.8/2

4.4

53.6

/24.

353

.0/2

4.0

58.8

/26.

762

.8/2

8.5

64.4

/29.

265

.0/2

9.5

63.4

/28.

870

.2/3

1.8

71.2

/32.

369

.8/3

1.7

69.4

/31.

570

.8/3

2.1

73.4

/33.

3

Not

es:

(1)

Ad

d a

‘C’ o

r ‘C

K’ a

fter

the

ca

paci

ty d

esig

nato

r fo

r 23

0V o

r 2

20V

/50

Hz

units

res

pe

ctiv

ely.

Exa

mp

les

ST

Q8

= 1

15V

, ST

Q8C

=23

0V, S

TQ

8CK

=2

20V

/50

Hz.

(2)

BT

U a

nd

ele

ctri

cal d

ata

are

base

d o

n a

45°

F /

7.2

°C e

vap

orat

or a

nd

100°

F /

37.8

°C c

on

den

ser

in c

oo

l mo

de,

an

d a

45°

F /

7.2

°C e

vap

orat

or a

nd

130°

F /

54.

4°C

co

nd

ense

r in

hea

t.(3

) N

ote:

60

Hz

units

mu

st n

ot o

per

ate

at 5

0H

z an

d 50

Hz

units

mu

st n

ot o

per

ate

at 6

0H

z.(4

) E

lect

ric

box

is r

emot

e m

ount

ed

up

to 3

4” (

0.8

6m

) aw

ay fr

om

co

mpr

esso

r. E

-box

dim

ensi

ons

are

2.7

” (6

9m

m)

x 6.

5” (1

65m

m)

x 8.

8”

(224

mm

).

† R

efer

s to

cal

lout

s sh

own

in d

raw

ing

bel

ow.

Sea

wat

er o

utle

tMou

ntin

g b

rack

ets

incl

uded

Con

den

sate

dra

in fi

ttin

g in

clud

ed

Sea

wat

er in

let

B

AB

CD