Tank inspection programs in accordance with EEMUA 159 guidelines determine if tanks are safe for continued service from a mechanical integrity standpoint. MISTRAS utilise both traditional and advanced NDT techniques for both In-Service and Out-of- Service inspections. Risk & Reliability To help tank owners comply with increasingly stringent regulations, risk-based inspection (RBI) systems and advanced non-destructive testing (ANDT) methods can be used to assess the condition and mechanical integrity of an individual tank or a complete tank farm. A tank- specific RBI approach will enable owners to focus their inspection on assets which have the highest probability of potential problems. Comprehensive Storage Tank Inspection Services EEMUA 159 Storage Tank Inspection Advanced / Traditional Non-Destructive Testing Prioritisation of tank floor inspections using Acoustic Emission Testing Tank Floor Scanning Utilising MFL Technology Ultrasonic Shell Crawler Corrosion & Minimum Thickness Evaluation Estimated Remaining Life Inspection Interval Determination RBI for determining Intervals & Workscopes Inspection Management Software (PCMS) Full Rope Access Capability Change of Service Effects on Suitability for Continued Service Evaluation of Tank Bottom & Foundation Conditions Evaluation of the Condition of associated Pipework Connections & Insulation Confidential Inspection Audits for Compliance to Codes & Standards Pre-Tank Outage Assessments One Source for Asset Protection Solutions www.mistrasgroup.co.uk STORAGE TANK INSPECTION - EEMUA 159 OIL & GAS / INDUSTRIAL