SmartLine Honeywell Technical Information STR800 SmartLine Remote Diaphragm Seals Specification 34-ST-03-88 Introduction Part of the SmartLine® family of products, the STR800 is a series of high performance pressure transmitters hydraulically matched and optimized with a complete set of remote diaphragm seals. Utilizing the same high performance sensor technology of the ST 800 product line Honeywell has optimized the mechanical and hydraulic designs in order to minimize the typical effects of temperature on remote seal systems. Best in Class Transmitter Features: • Accuracies up to 0.065% standard • Automatic static pressure & temperature compensation • Multiple local display capabilities • External zero, span, & configuration capability • Polarity insensitive electrical connections • Comprehensive on-board diagnostic capabilities • Integral Dual Seal design for highest safety based on ANSI/NFPA 70-202 and ANSI/ISA 12.27.0 • World class overpressure protection • Full compliance to SIL 2/3 requirements. • Modular design characteristics • Available with 15 year warranty Remote Seal/Transmitter Span & Range Limits: Model URL “H20 (mbar) LRL • h 2 o (mbar) Max Span ••h 2 o (mbar) Min Span ••h 2 o (mbar) STR82D 400(1000) -400 (-1000) 400 (1000) 4.0 (10) Model psid (bar) psid (bar) psid (bar) psid (bar) STR83D 100 (7.0) -100 (-7.0) 100 (7.0) 1 (0.07) Model psig (bar) psig (bar) psig (bar) psig (bar) STR84G 500 (35.0) -14.7 (1.0) 500 (35.0) 5 (0.35) STR87G 3000 (210) -14.7 (1.0) 3000 (210) 30 (2.1) Model psia (bara) psig (bara) psig (bara) psig (bara) STR84A 500 (35) 0(0) 500 (35) 5 (0.35) Figure 1 - STR800 Remote Diaphragm Seal Unit Typical Diaphragm Seal applications • High Process Temperatures • Viscous or Suspended Solids • Highly Corrosive Process Materials • Sanitary Applications • Applications with Hydrogen Permeation Possibilities • Level Applications with Maintenance Intensive Wet Legs • Applications requiring remote Transmitter Mounting • Tank Applications with Density or Interface Measurements Communications/Output Options: • Honeywell Digitally Enhanced (DE) • HART ® (version 7.0) • FOUNDATION™ Fieldbus All transmitters are available with the above listed communications protocols. По вопросам продаж и поддержки обращайтесь: Астана +7(7172)727-132, Волгоград (844)278-03-48, Воронеж (473)204-51-73, Екатеринбург (343)384-55-89, Казань (843)206-01-48 Краснодар (861)203-40-90, Красноярск (391)204-63-61, Москва (495)268-04-70, Нижний Новгород (831)429-08-12, Новосибирск (383)227-86-73, Ростов-на-Дону (863)308-18-15, Самара (846)206-03-16, Санкт-Петербург (812)309-46-40, Саратов (845)249-38-78, Уфа (347)229-48-12 ' Единый адрес: [email protected]www.honeywell.nt-rt.ru
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
All transmitters are available with the above listed
communications protocols.
По вопросам продаж и поддержки обращайтесь:Астана +7(7172)727-132, Волгоград (844)278-03-48, Воронеж (473)204-51-73, Екатеринбург (343)384-55-89, Казань (843)206-01-48
Краснодар (861)203-40-90, Красноярск (391)204-63-61, М осква (495)268-04-70, Н и ж н и й Н овгород (831)429-08-12, Н овосибирск (383)227-86-73, Ростов-на-Дону (863)308-18-15, Самара (846)206-03-16, С анкт-П етербург (812)309-46-40,
Саратов (845)249-38-78, Уфа (347)229-48-12 'Единый адрес: hw n@ nt-rt.ru
The SmartLine family of gauge pressure, differential pressure, and absolute pressure transmitters is designed around a high performance piezo-resistive sensor. This one sensor actually integrates multiple sensors linking process pressure measurement with on-board static pressure (DP Models) and temperature compensation measurements resulting in the best total performance available. This level of performance allows the ST 800 to replace virtually any competitive transmitter available today.
Unique Indication/Display OptionsThe ST 800 modular design accommodates a basic
alphanumeric LCD display or a unique advanced graphics
LCD display with many unparalleled features.
Basic Alphanumeric LCD Display Featuresо Modular (may be added or removed in the field) о 0, 90,180, & 270 degree position adjustments
о Pa, KPa, MPa, KGcm2, Torr, ATM, i4H20 , mH20 , bar,
mbar, inH20 , inHG, FTH20 , mmH20 , mm HG, & psi
measurement units
о 2 Lines 16 Characters (4.13H x 1.83W mm)
о Square root output indication (V)
Advanced Graphics LCD Display Featuresо Modular (may be added or removed in the field) о 0, 90, 180, & 270 degree position adjustments о Standard and custom measurement units available, о Up to eight display screens with 3 formats are possible
(Large PV with Bar Graph or PV with Trend Graph) о Configurable screen rotation timing о Display Square Root capabilities may be set separately
from the 4-20mA dc output signal о Unique “Health Watch” indication provides instant visibility
of diagnostics
о Multiple language capability. (EN, GE, FR, IT, SP, RU,TR, CN, JP)
DiagnosticsSmartLine transmitters all offer digitally accessible diagnostics which aid in providing advanced warning of possible failure events minimizing unplanned shutdowns, providing lower overall operational costs
Configuration ToolsIntegral Three Button Configuration OptionSuitable for all electrical and environmental requirements, SmartLine offer the ability to configure the transmitter and display via three externally accessible buttons when either display option is selected. Zero/span capabilities are also optionally available via these buttons with or without selection of a display option.
Hand Held ConfigurationSmartLine transmitters feature two-way communication and configuration capability between the operator and the transmitter. This is accomplished via Honeywell’s field-rated Multiple Communication Configurator (MCT202).The MCT202 is capable of field configuring DE and HART Devices and can also be ordered for use in intrinsically safe environments. All Honeywell transmitters are designed and tested for compliance with the offered communication protocols and are designed to operate with any properly validated hand held configuration device.
Personal Computer ConfigurationHoneywell’s SCT 3000 Configuration Toolkit provides an easy way to configure Digitally Enhanced (DE) instruments using a personal computer as the configuration interface. Field Device Manager (FDM) Software and FDM Express are also available for managing HART & Fieldbus device configurations.
System Integrationо SmartLine communications protocols all meet the most
current published standards for HART/DE/Fieldbus.
о Integration with Honeywell’s Experion PKS offers the
following unique advantages,
о Transmitter messaging
о Maintenance mode indication
о Tamper reporting
о FDM Plant Area Views with Health summaries
о All ST 800 units are Experion tested to provide the
highest level of compatibility assurance
Modular DesignTo help contain maintenance & inventory costs, all STR800 transmitters are modular in design supporting the user’s ability to replace or add indicators, terminal connections or electronic modules without affecting overall performance or approval body certifications
Modular Featuresо Exchange/replace electronics/comms modules* о Add or remove integral indicators* о Add or remove lightning protection (terminal connection)*
* Field replaceable in all electrical environments (including IS) except flameproof without violating agency approvals.
With no performance effects, Honeywell’s unique modularity results in lower inventory needs and lower overall operating costs.
STR800 Smart Pressure Transmitter 3
Performance Specifications1
Reference Accuracy2 (conformance to +/-3 Sigma)
Model URL LRL Min Span
MaximumTurndown
Ratio
Reference Accuracy1 (% Span)
STR82D 400 in H20/1000m bar -400 in H20/-1000mbar 4 in H20/10m bar 100:1 0.065STR83D 100 psid/7.0 bar -100 psi/-7.0bar 1 in psi/.07bar 100:1 0.065STR84G 500 psi/35 bar -14.7/-1.0 bar 5 psi/0.35 bar 100:1 0.065STR87G 3000 psi/210 bar -14.7 psi/-1.0 bar 30 psi/2.1 bar 100:1 0.065STR84A 500 psia/35 bara 0 psia/0 bara 5 psia/0.35 bara 100:1 0.065
Zero and span may be set anywhere within the listed (URL/LRL) range limits
Accuracy at Specified Span, Temperature and Static Pressure: (conformance to +/-3 Sigma)
Total Performance = +/- V ( Accuracy)2 + (Temp Effect)2
Total Performance Examples: (5:1 Turndown, up to 50 °F shift)
STR82D @ 80”H20 : 2.68% of span STR83D @ 20 psid: 0.45% of span
Typical Calibration Frequency:Calibration verification is recom m ended every four (4) years
Notes:1 Term inal Based Accuracy - Includes combined effects of linearity, hysteresis, and repeatability. Analog output adds 0.005% of span.
2. For zero based spans and reference conditions of 25°C (77°F), 0 psig static pressure, 10 to 55% R.H, and 316 Stainless Steel barrier
diaphragms
3. Specification applies to transmitter with 2 seals. Apply a 1.5 factor for temperature effect for capillary lengths greater than 10 feet.
4 STR800 Smart Pressure Transmitter
Operating Conditions - All Models
ParameterReference
Condition (at zero static)
Rated Condition Operative Limits Transportation and Storage
°c °F °c °F °c °F ° c °FAmbient Temperature1 25±1 77±2 - - - - -55 to 90 -67 to 194
Humidity %RH 10 to 55 0 to 100 0 to 100 0 to 100
Vacuum Region, Minimum Pressure
mmHg absolute Atmospheric (See Figure 4 for vacuum limitation)
Supply Voltage, Current, and Load Resistance
10.8 to 42.4 Vdc at terminals (IS versions limited to 30 Vdc) 0 to 1,440 ohms (as shown in Figure 2)
Maximum Allowable Working Pressure (MAWP)4(S T 800 p roducts are rated to M ax im um A llo w a b le W ork ing P ressure . M A W P dep ends on A p p ro va l A g e n cy and tra n sm itte r m a te ria ls of cons truc tion .)
MAWP is minimum of Body Rating or Seal Rating (See Model Selection Guide for Seal MAWP)
Body MAWPSTR82D 2,500 psig (172 bar) Bolted Process Heads
STR83D 2,500 psig (172 bar) Bolted Process Heads STR82D 1,450 psig (100 bar) All Welded Process
' Ambient Temperature Limit is a function of Process Interface Temperature and fill fluid. (See Figure 23 & Figure 4) LCD Display operating temperature -20°C to +70°C . Storage temperature -30°C to 80°C
4 Consult factory for MAWP of ST 800 transmitters with CRN approval.
LoopResistance
(ohms)
Note: A minimum of 250 ohms of loop resistance is required to support communications. Loop resistance = barrier resistance + wire resistance + receiver resistance.
A = Operating Area
Operating Voltage ( Vdc)
Run™ = 45 .6 x (P ow er S u p p ly V o ltage - 10.8)
Maximum Ambient Temperature (°F)
200 350 450
Process Interface Temperature (°F)
Figure 2 - Supply voltage and loop resistance Figure 3 - Ambient temperature Limits
STR800 Smart Pressure Transmitter 5
Maximum Pressure Limited
Process Temperature (Degrees F)Maximum Pressure Limited
Process Temperature (Degrees F)
Figure 4 - STR800 Remote Seals operable limits for pressure vs. temperature
6 STR800 Smart Pressure Transmitter
Performance Under Rated Conditions - All ModelsParameter Description
Analog Output Digital Communications:
Two-wire, 4 to 20 mA (HART & DE Transmitters only)Honeywell DE, HART 7 protocol or Fo u n d atio n Fieldbus ITK 6.0.1 compliant
All transmitters, irrespective of protocol have polarity insensitive connection.
Output Failure Modes Honeywell Standard: NAMUR NE 43Compliance:Normal Limits: 3 .8 -2 0 .8 mA 3 .8 -2 0 .5 mA
Failure Mode: s 3.6 mA and 5 21.0 mA s 3.6 mA and 5 21.0 mA
Supply Voltage Effect 0.005% span per volt.
Transmitter Turn on Time (includes power up & test algorithms)
HART or DE: 2.5 sec. Foundation Fieldbus: Host dependant
Damping Time Constant HART: Adjustable from Oto 32 seconds in 0.1 increments. Default: 0.50 seconds DE: Discrete values 0, .16, .32, .48, 1, 2, 4, 8, 16, 32 seconds. Default: 0.48 seconds
Materials Specifications (see Model Selection Guide for availability/restrictions with various models)___________________ ________________________________________________________________Parameter Description
Process Interface See Model Selection Guide for Material Options for desired seal type.
Seal Barrier Diaphragm 316L Stainless Steel, Monel®, Hastelloy®C, Tantalum
Seal Gasket Materials Klinger C-4401 (non-asbestos), Grafoil®, Teflon®, Gylon 3510®
Mounting Bracket Carbon Steel (Zinc-Chromate plated) or 304 Stainless Steel or 316 Stainless Steel
Fill Fluid (Meter Body)Silicone Oil 200 S.G. @ 25°C = 0.94 CTFE (Chlorotrifluoroethylene) S.G. @ 2 5 °C = 1.89
Electronic Housing Pure Polyester Powder Coated Low Copper (<0.4%)-Aluminum. Meets NEMA 4X, IP66, & P67. All stainless steel housing is optional.
Capillary Tubing
Material: Armored Stainless Steel or PVC Coated Armored Stainless Steel. Length: 5, 10, 15, 20, 25, and 35 feet (1.5, 3, 4.6, 6.1, 7.5, and 10.7 meters). A 2 inch (51 millimeter) S.S. close-coupled nipple is also available. See Model Selection Guide. Refer to Figure 5 for guide to maximum capillary length vs. diaphragm diameter.
Wiring Accepts up to 16 AWG (1.5 mm diameter)
Mounting See Figure 6
Dimensions Transmitter: See Figure 7 and Figure 8. Seal: See Figure 9 through Figure 17
Net Weight Transmitter: 8.3 pounds (3.8 Kg). With Aluminum Housing. Total weight is dependent on seal
NOTE: Pressure transmitters that are part of safety equipment for the protection of piping (systems) or vessel(s) from exceeding allowable pressure limits, (equipment with safety functions in accordance with Pressure Equipment Directive 97/23/EC article 1, 2.1.3), require separate examination.
STR800 Smart Pressure Transmitter 7
Minimum recommended span for STR82D and STR83D Transmitter with two Remote Seals
DiaphragmSize
Capillary Capillary Length Maximum5” 10” 15”
оCM 30” 35”2.4 200 iwc 5 ’
2.9 100 iwc 125 iwc 150 iwc 175 iwc 20'
3.5 16 iwc 20 iwc 24 iwc 28 iwc 36 iwc 40 iwc 35'
4.1 12 iwc 15 iwc 18 iwc 21 iwc 27 iwc 30 iwc 35'
Minimum recommended span for STR82D and STR83D Transmitter with one Remote Seal
N O T E : Low er f la n g e s e a l s h o u ld no t be m o u n te d o v e r 22 fe e t b e lo w o r a b o v e th e t ra n s m it te r f o r s il ic o n e f i l l f lu id (11 fe e t f o r C T F E f i l l f lu id ) w ith ta n k a t o n e a tm o s p h e re . T h e c o m b in a tio n o f ta n k v a c u u m a n d h igh p re s s u re c a p illa ry h ead e f fe c t sh o u ld no t e x c e e d 9 ps i v a c u u m (3 0 0 m m H g a b s o lu te ) .
Figure 6 - STR800 transmitter with remote diaphragm seals shown mounted on a tank
8 STR800 Smart Pressure Transmitter
Reference Dimensions Horizontal Mounting
STR800 Smart Pressure Transmitter 9
Reference Dimensions Horizontal Mounting (cont’d)
LGP REMOTE SEAL WITH HORIZONTAL PIPE MOUNT
Figure 7 — Approximate horizontal mounting dimensions for Remote Seal Transmitter
Reference Dimensions Vertical Mounting
127,05,00
CLEARANCE FOR ENDCAP REMOVAL
& DISPLAY MANIPULATION
125.9 4-96
WfTlH DISPLAY ENDCAP OR
IT 6.0 4.57
WITH SOLID ENDCAP ON ELECTRONICS END
127.05.00CLEARANCE FOR ENDCAP REMOVAL & FIELD TERMINAL CONNECTIONS
SEAL OMITTED IN THIS VIEW FOR CLARITY
DP REMOTE SEAL WITH VERTICAL PIPE MOUNT
SEAL OMITTED IN THIS VJEW FOR CLARITY
10 STR800 Smart Pressure Transmitter
Reference Dimensions Vertical Mounting (cont’d)
LPG REMOTE SEAL WITH VERTICAL PIPE MOUNT
Figure 8 — Approximate vertical mounting dimensions for Remote Seal Transmitter
STR800 Smart Pressure Transmitter 11
Reference Dimensions (cont’d)
Flush Flanged Seal Dimensions
ANSI/DIN FlangeWetted Materials
Type <— УRating Material D iaphragm Body See figure
A ВSS SS D
Hasielloy С SS СCS Hasielloy С
Mnne:Hastslloy С
Mon elDD
7.5 1.37
Э" CI-лЬЕ- Tantalum SS С153* S3
Hasielloy СN/ASS
ВA
0.94
SS Hasielloy С Manei
Tantalum
Ha&telloy С Mori el
SS
DDС
7.501.37
SS SS DHasielloy С SS С
CS hasielloy С
Mane
Habtelloy С Monel
DD
&.35 1.5В
Э" Class Tantalum SS С3D0£ SS N/A В
1.12Hasielloy С SS A
ss Hasielloy С Ha&tslloy С D 8.25
FlushFlanged
•Seal
Me nei Tantalum
MonelSS
DС
1.56
SSHasielloy С
SSSS
DС
CS Hasielloy С Mone'
Habtelloy С Monel
DD
3.25 1.75
Э" Class Tantalum SS С600 * SS
Hasielloy СN/ASS
ВA
15
ss Hasielloy С Mone1
Tantalum
Ha&telloy С Monsl
SS
DDС
3.251.75
S3 SS DHasielloy С SS С
CS Hasielloy С Monei
Habtslloy С Mon si
DD
7.B7 1.32
□h*S0-PM4CTantalum SB С
SS Hasielloy С
N/ASS
ВA
0.34
S5 Hasielloy С
Mane1 Tantalum
Ha=.telloy С Mon el
SS
DDС
7.071.32
Figure A
Configuration "HT"
Figure В
D iaph ragm e x tends the en tire R a ised fa ce ga ske t su rfa ce (w e tted)
(e ffec tive d ia p h ra g m )
(d ia p h ra g m ) -------- ►
Configuration "HS"
F lange (N on -w e tted )
R a ised fa c e G aske t su rfa ce (w e tte d )
Flange - (Non-W etted)
Body(non-wetted)
Configuration "IS"
Diaphragm extends over the entire Raised face gasket surface (wetted)
Vmax= Ui = 30V lmax= li= 105mA C i=4.2nF Li =984 uH Pi =0.9W
Transm itter w ith Terminal Block Revision E or L a te r)Vmax= Ui = 30V lmax= li= 225mA C i=4.2nF Li = 0 Pi =0.9WNote : Transm itter w ith Terminal Block Revision E or laterThe revision is on the label th a t is on the module. There w ill be tw o lines o f te x t on the label:
• First is the M odule Part #: 50049839-001 o r 50049839-002• Second line has the supplier in fo rm a tion , along w ith the REVISION:
XXXXXXX-EXXXX, THE "X" is production related, THE POSITION o f the "E" IS THE REVISION.
b. Foundation Fieldbus- Entity ValuesVmax= Ui = 30V lmax= li= 180mA C i=0nF Li = 984uH Pi =1W
Transm itter w ith Terminal Block Revision F or L a te r)Vmax= Ui = 30V lmax= li= 225mA Ci =0nF Li = 0 Pi =1 W
FISCO Field Device lmax= li= 380 mA C i=0nF Li = 0 Pi =5.32 WVmax= Ui = 17.5VNote : Transm itter w ith Terminal Block Revision F or laterThe revision is on the label th a t is on the module. There w ill be tw o lines o f te x t on the label:
• First is the M odule Part #: 50049839-003 o r 50049839-004• Second line has the supplier in fo rm a tion , along w ith the REVISION:
ХХХХХХХ-ЕХХХХ, THE "X" is production related, THE POSITION o f the "E" IS THE REVISION.
20 STR800 Smart Pressure Transmitter
Approval Certifications: (Continued)
Marine Certificates
This certificate defines the certifications covered for the ST 800 Pressure Transmitter family of
products, including the SMV 800 Smart Multivariable Transmitter. It represents the compilation of
the five certificates Honeywell currently has covering the certification of these products into marine
applications.
For ST 800 Smart Pressure Transmitter and SMV800 Smart Multivarible Transmitter
American Bureau of Shipping (ABS) - 2009 Steel Vessel Rules 1-1-4/3.7, 4-6-2/5.15, 4-8-3/13 &
Pmax = (SGmax _ ®®f) x (d); maximum density, 20mA output
Where:
d = distance between the taps
SGmax = maximum Specific Gravity
SGmjn = minimum Specific Gravity
Seal Configurations
Figure 21— Flush Flange SealsFlush Flange Seals can be used with differential, gauge and absolute pressure transmitters and are available with 3” ANSI Class 150, ANSI Class 300 and DIN DN80-PN40 process connections. Flush flange seals can also be provided with Lowers. Lowers are essentially calibration rings, which allow flushing connections if needed.
SGf = Specific Gravity of capillary fill fluid (See Page 6 “Material Specifications” for values.)
Figure 20— Density, direct acting transmitter configuration
Figure 23— Pancake SealsPancake Seals can be used with differential, gauge and absolute pressure transmitters and are available with 3” ANSI Class 150, 300 and 600 process connections.
Figure 22— Flange Seal with Extended DiaphragmFlange Seal with Extended Diaphragm can be used with differential, gauge and absolute pressure transmitters and are available with 3” and 4” ANSI Class 150, ANSI Class 300, DIN DN80-PN40 and DIN DN100-PN40 process connections. 2”, 4” and 6” extension lengths are available
Figure 24— Chemical Tee “Taylor” WedgeChemical Tee “Taylor” Wedge can be used with differential pressure transmitters and are available with Taylor Wedge 5” O.D. process connection.
STR800 Smart Pressure Transmitter 23
Seal Configurations (cont’d)
Figure 25— Seals with Threaded Process Connections
Seals with Threaded Process Connections can be used with differential, gauge and absolute pressure transmitters and are available with Vi', %” and 1” NPT Female process connections.
Stainless Steel Armor and PVC Coated Stainless SteelArmor Capillaries are available with Honeywell RemoteSeal Solutions.
Figure 26— Sanitary Seals Figure 30— 2” Stainless Steel NipplesSanitary Seals can be used with differential, gauge and 2” Stainless Steel Nipples are available for Close-absolute pressure transmitters and are available with 3” Coupled remote seal solutions
and 4” Tri-Clover-Tri-Clamp process connections.
Figure 27— Saddle SealsSaddle Seals can be used with differential, gauge and absolute pressure transmitters and are available with 3" and 4” (6 bolt or 8 bolt designs) process connections.
■ ^
Figure 31— Welded Meter Body for All-Welded Remote Seal Solution
Welded Meter Body for All-Welded Remote Seal Solution.The welded ST 800 meter body is an important part of anAll-Welded Remote Seal Solution, which is commonlyused in Vacuum applications.
Figure 28— Calibration RingsCalibration Rings are available with Flush Flange Seals and Pancake Seals. Flushing ports (1/4” or V2”) are available with calibration rings.
24 STR800 Smart Pressure Transmitter
Model Selection GuideModel Selection Guides are subject to change and are inserted into the specifications as guidance only.Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at:
Model STR800 (DP, GP & AP) Remote Seals
Model Selection Guide 34-ST-16-88 Issue 5
In s tru c t io n s• Select the desired Key Number. The arrow to the right marks the selection available.• Make selections from each Table (I, II and IX) using the column below the proper arrow.• A (•) denotes unrestricted availability. A letter denotes restricted availability.• Restri cti ons fol I ow Tabl e IX.
Key Number_________ I___________ _________II________ III IV V VI VII VIII
STR I -1 -- I -1 — -1 П П П Г1 I I ГП
KEY NUM BER URL LRL Max Span Min Span Units Selection Availability
4 Plastic Plugs are TE M P O R AR Y ONLY to protect threads and M UST be REMOVED before installation5 Tantalum Upper insert has Tantalum wetted parts and 316 SS or CS non-wetted parts
Note: Rem ote seal system pressure rating is body rating or seal rating, w h ichever is less.
26 STR800 Smart Pressure Transmitter
STR84G & 87G & 84A -------
STR 82D & 83D ---------
TABLE II Descripton Selection
Seal TypeDiaphragmDiameter
FlangeSize
Flange Pressure
Rating 1Const. - See Spec. Figure 34-ST-03-88
Construction - See Spec. Figure 34-ST-03-88
1"ANSI 150 ANSI 300
2222
BCABCC
1212
••
2.4"1-1/2"
ANSI 150 ANSI 300
2222
BGABGC
1212
••
2"ANSI 150 ANSI 300
2222
BDABDC
1212
••
3"ANSI 150 ANSI 300
2222
В FA BFC
1212
••
1/2" ANSI 150 23 CAA • •
1"ANSI 150 ANSI 300
2323
CCACCC
••
••
2.9"1-1/2"
ANSI 150 ANSI 300
2222
CGACGC
••
••
2"ANSI 150 ANSI 300
2222
CDACDC
••
••
1/2" ANSI 150 22 DAA • •
1"ANSI 150 ANSI 300
2323
DCADCC
••
••
4.1"1-1/2"
ANSI 150 ANSI 300
2323
DGADGC
••
••
€ 'Jw 2"ANSI 150 ANSI 300
2322
DDADDC
••
••
Seals (continued) Flush Flanged3"
ANSI 150 ANSI 300
2222
DFADFC
••
••
Seal Diaphragm Lower Selectionwith Lower
Wetted Material
316LSS Hastelloy® C -276
Hastelloy® C -276
Monel 400® Tantalum Tantalum Tantalum
316LSS 316LSS
Hastelloy® C-276
Monel 400® 316LSS
Hastelloy® C-276
Tantalum Clad
_ BA_____ B B __________ B C______
BE____ B F __________ BG __________ B H______
•••88813
•••88813
Non-Weiied Material (upper, upper insert)
Upper Upper Insert Selection316LSS
Carbon Steel316LSS316LSS
45
••
••
Bolts6 No Selection 0 • •
Flushing None 0 • •Connections
and Plugs4(M etal plug m ate ria l
w ill be the sam e as
Low er m ate ria l, if
m eta l p lug is chosen -
(SS Plug fo r CS Lower
and Tan ta lum C lad)
One 1/4" with plastic plug One 1/4" with metal plug
Two 1/4" with plastic plugs Two 1/4" with metal plugs One 1/2" with plastic plug One 1/2" with metal plug
Two 1/2" with plastic plugs Two 1/2" with metal plugs
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I й
л D
"O1
l I
1 l
I I •
•••••••
••••••••
Gasket
Klinger® C-4401 (non-asbestos)
Grafoil®Teflon®Gylon®3510
К
GT
L
•
••15
•
••15
Table II continued next page
1 S tandard fac ina 125-250 AA R H RF (ra ised face) serra ted surface finish.6 Bolt m ate ria l w ill be sam e as UDDer M ateria l. However, if Tab le I bo lts /nu ts m ate ria l is N A C E or B7M, seal bolt m ate ria l w ill be 304 SS NACE. 4 P lastic P luas are T E M P O R A R Y O N LY to Drotect th reads and M U S T be R E M O VE D before insta lla tion
Note: R em ote seal system pressure ra ting is body rating o r seal rating, w h icheve r is less.
STR800 Smart Pressure Transmitter 27
STR84G & 87G & 84A
S TR 82D & 83D
T A B L E II Descripton
Seals (continued)
S eal TypeD iaphragm D iam ete r
FlangeSize
Flange P re s s u re Rating 1 S e le c tio n
2.8"3"
(2.8" OD extension)
ANSI C lass 150 ANSI C lass 300 DIN DN80-PN40
EFAEFCEFM
•
•
•
•••
3.5"4"
(3.70" OD extension
ANSI C lass 150 ANSI C lass 300
DIN DN100-PN40
FGAFGCFGP
•••
•
•
•
Flange Seal with Extended
DiaphragmWetted Material
D iaphragm Ext. Tu be Selection316L SS
Hastelloy® C-276 Hastelloy® C-276
316L SS 316L SS
Hastelloy® C-276
____ EA___________ E B _______
_ E C ______
•
•
•
•
•
•
Non-Wetted Material (flange)
CS (Nic 31i
kel Plated) 5L SS
78
•
•
•
•
Bolts No Selection 0 • •
Extension Length2"4"6" I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
(t ̂
B
I I
I •••
•
•
•
No Selection No Selection No Selection 0 • •Table II c o n tin u e d b e lo w
STR84G & 87G & 84A
S TR 82D & 8 3 D ------
TABLE II Descriptor!
S eal Type
Seals (continued)
Pancake Seal
D iaphragmD ia m e te r
3.5"
FlangeSize
3"
Wetted Material
Non-Wetted Material
BoltsCalibration Ringso
Flushing Connections
and Plugs4(Metal plug material w ill be the same as Cal. Ring material, if
metal plug is chosen)
Flange P re s s u re Rating D ep en d e n t on C u s to m e r Flange S e le c tio n
ANSI C lass 150/300/600 GFAD iaphragm316L SS
Hastelloy® C-276 Hastelloy® C-276
Monel 400® Tantalum
Body316L SS 316L SS
Hastelloy® C-276
Monel 400® Tantalum 7
. GA_ _GB_ . GC_ . GE_
GG
No Selection
No SelectionNone
316L SS
Hastelloy® C-276 Monel 400®
_ A_ . B_ C_ D
NoneOne 1/4 One 1/4
Two 1/4" Two 1/4" One 1/2 One 1 /2
Two 1/2"
Two 1/2"
with plastic plug " with metal plug with p lastic plugs with metal plugs
' with plastic plug " with metal plug with p lastic plugs
with metal plugs
. H _ J _M
. N
. P Q
. R S
101010
Table II c o n tin u e d nex page
00
0
1 Standard facing 125-250 AARH RF (raised face) serrated surface finish.4 Plastic Hugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation 7 Tantalum Body has Tantalum wetted parts and 316 SS non-wetted parts
Note: Remote seal system pressure rating is body rating or seal rating, w hichever is less.
28 STR800 Smart Pressure Transmitter
STR84G & 87G & 84A
STR82D & 83D --------
TABLE II Descripton
Seal Type
Seals (continued)
Chemical Tee "Taylor" Wedge
DiaphragmDiameter
3.5"
FlangeSize
Taylor Wedge 5" O.D.
Wetted Material
Non-Wetted MaterialBoltsStyles
No Selection
Flange Pressure Rating 1 Selection
750 psi HMO
Diaphragm316L SS
Hastelloy® C-276
Hastelloy® C-276
Body Selection316L SS 316L SS
Hastelloy8 C-276
. HA_
. HB_ HC
No SelectionNo SelectionNo SelectionNo Selection
16
TABLE II
Seals (continued)
Seal Type
Seal with Threaded Process
Connection
DiaphragmDiameter
2.4"
2.9"
4.1"
DescriptonThreaded Process Connection Size
(NPT Female)
1/2 NPT 3/4 NPT 1 NPT
1/2 NPT 3/4 NPT 1 NPT
1/2 NPT 3/4 NPT 1 NPT
Wetted Material
Non-Wetted Material (upper)
FlushingConnections
and Plugs4(Metal plug m aterial
w ill be the sam e as
Low er m aterial, if
m eta l plug is chosen
(SS Plug fo r CS Low er
and Tanta lum Clad)
Gasket
Pressure Rating
CS Bolts
2,500psi
2,500psi
1,500psi
Diaphragm
316L SS 316L SS
Hastelloy® C-276
Hastelloy® C-276
Monel 400® Tantalum Tantalum
304 SS Bolts
1,250psi
1,250psi
750psi
Lower
Carbon Steel 316L SS 316L SS
Hastelloy® C-276
Monel 400® 316L SS
Hastelloy® C-276
CS (Nickel Plated) 316 Stainless Steel
Carbon Steel 304 SSNone
One 1/4' One 1/4'
Two 1/4" Two 1/4" One 1/2" One 1/2'
Two 1/2" Two 1/2"
with plastic plug " with metal plug with plastic plugs with metal plugs with plastic plug with metal plug
Standard facing 125-250 AARH RF (raised face) serrated surface finish.
4 P lastic Plugs are TEM PO R ARY O NLY to protect threads and M UST be REMOVED before installation
8 If Table I Bolts and Nuts m aterial option is NACE, Bolts and Nuts will ship with A lloy Steel NACE and M AW P m ay change.
00
00
Note: Rem ote seal system pressure rating is body rating or seal rating, w h ichever is less.
STR800 Smart Pressure Transmitter 29
TABLE II Descriptor!
STR84G & 87G & 84A
STR82D & 83D ---------
Seal Type
Seals (continued)
Sanitary Seal
DiaphragmDiameter
1.9"
2.4"
2.9"4.1"
FlangeSize
2 "
2- 1/ 2 "
3"4"
Wetted Material
Non-Wetted Material
Bolts
Styles
Gasket
Pressure Rating
Customer clamp rating or 600 psi. whichever is less
Diaphragm
316LSSBody
316LSS
No Selection
No Selection
Tri-Clover Tri-ClampNo Selection
Selection
MDO
NEO
PFO _ QGO
Selection
N A
0Table II continued below
TABLE II
Seals (continued)
Descripton
Seal Type
Saddle Seal
DiaphragmDiameter
2.4"8-BoltDesign
2.4"6-BoltDesign
Size and Bolt
Pattern
fo r 3" Pipe a 4" pipe
fo r 3" Pipe a 4" pipe
Wetted Material
Non-Wetted Material
BoltsStyles
Gasket
Seal Pressure Rating
C.S. Bolts
2,500 psi
2,000 psi
Diaphragm316LSS
316LSS
Hastelloy® C -276
Hastelloy® C -276
316LSS
Hastelloy® C -276
BodyCarbon Steel
316LSS
316 SS Bolts
1,250 psi
1,000 psi
Lower Housing
Carbon Steel 316LSS
316LSS
Hastelloy® C -276
N /A -B o dy O n ly 10
N /A -B o dy O n ly 10
Carbon Steel
316SSNo Selection
No Selection
Klinger® C-4401 (non-asbestos)
Grafoil®Teflon®Gvlon®3510
STR84G & 87G & 84A
STR82D & 83D ---------
Selection
RFK_
RGK
RPK
RQK
SelectionRA
RB
.RC_ _ RD _
_SB_
SCSelection
В
_G_T
L
0
08
00
к
9 A ll san ita rv sea ls have da irv nrade ЗА ann rova l10 Rolfs are not inc luded w ith "hodv on lv" se lec tion11 If Tab le I Rolfs and N u ts m ate ria l on tion is N A C F . seal bolt m a te ria l w ill be 304 S S N A C F
N ote : R em ote seal system pressure rating is body ra ting o r seal rating, w h ich e ve r is less.
30 STR800 Smart Pressure Transmitter
STR84G & 87G & 84A —
STR82D & 83D ~ |
TABLE III Agency Approvals (see data sheet for Approval Code Details)
Enabled N/A N/A Fieldbus or ProfibusDisabled N/A N/A Fieldbus or Profibus
c. General Factory StandardConfiguration Custom Configuration (Unit Data Required from customer)
I 1 — I • M
_ 1 _ f f_ 2 _ f f_ 3 _ f f_ 4 _ f f_ 5 _ g g_ 6 _ g g_ _ S • •__ С • •
TABLE VI CALIBRATION & ACCURACY SELECTIONS
Accuracy and Calibration
A ccuracy C alib ra ted Range C alibration Qty
NA None None
StandardStandard
Factory Std Custom (Unit Data Required)
Single Calibration Single Calibration
0 21 21A • •В • •
3 NAMUR Output Limits 3.8 - 20.5mAdc can be configured by the customer or select custom configuration Table Vc
STR800 Smart Pressure Transmitter 31
STR84G & 87G & 84A
STR82D & 83D -
TABLE VII ACCESSORY SELECTIONS
a. Mounting Bracket
B racket Type M ateria lN o n e
A n g le B ra c k e t A n g le B ra c k e t A n g le B ra c k e t
M a r in e A p p ro v e d A n g le B ra c k e t F la t B ra c k e t F la t B ra c k e t F la t B ra c k e t
N o n e
C a rb o n S te e l 3 0 4 S S 3 1 6 S S 3 0 4 S S
C a rb o n S te e l 3 0 4 S S 3 1 6 S S
b. Customer Tag
C u s to m er Tag TypeN o c u s t o m e r ta gO n e W ire d S ta in le s s S te e l T a g (U p to 4 l in e s 2 6 c h a r / l in e ) T w o W ire d S ta in le s s S te e l T a g (U p to 4 l in e s 2 6 c h a r / l in e )
c. Unassembled Conduit
Plugs & Adapters
U nassem bled Conduit Plugs & A dapters
N o C o n d u i t P lu g s o r A d a p te rs R e q u ir e d
1 /2 N P T M a le to 3 /4 N P T F e m a le 3 1 6 S S C e r t i f ie d C o n d u i t A d a p te r
1 /2 N P T 3 1 6 S S C e r t i f ie d C o n d u i t P lu g M 2 0 3 1 6 S S C e r t i f ie d C o n d u i t P lu g
M in i fa s t® 4 p in (1 /2 N P T )
M in ifa s t® 4 p in (M 2 0 )
0 • •1 • •
_ 2 ___ • •
0 • •
1 • •
2 • •
3 • •
4 •
5 • •
6 • •
7 • •
A0 • •
A 2 n nA 6 n n
_ A 7 m mA 8 n n
_A9 m m
TABLE VIII
Certifications & Warranty
O lHhK Certifications & Options : (Stn ng in sequence comma delimited (XX, XX, X X ,.
N o n e - N o a d d it io n a l o p t io n sN A C E M R 0 1 7 5 ; M R 0 1 0 3 ; IS 0 1 51 5 6 ( F C 3 3 3 3 8 ) P r o c e s s w e tte d p a r ts o n ly N A C E M R 0 1 7 5 ; M R 0 1 0 3 ; IS 0 1 51 5 6 ( F C 3 3 3 3 9 ) w e tte d a n d n o n -w e t te d p a r ts M a r in e (D N V , A B S , BV , K R , L R ) (F C 3 3 3 4 0 )E N 1 0 2 0 4 T y p e 3.1 M a te r ia l T r a c e a b i l i ty ( F C 3 3 3 4 1 )C e r t i f ic a te o f C o n fo rm a n c e (F 3 3 9 1 )
C a lib ra t io n T e s t R e p o r t & C e r t i f ic a te o f C o n fo r m a n c e (F 3 3 9 9 )C e r t i f ic a te o f O r ig in (F 0 1 9 5 )F M E D A ( S IL 2 /3 ) C e r t i f ic a t io n ( F C 3 3 3 3 7 )O v e r - P r e s s u r e L e a k T e s t C e r t i f ic a te ( 1 .5 X M A W P ) (F 3 3 9 2 )C e r t C le a n fo r 0 2 o r C L 2s e r v ic e p e r A S T M G 9 3
E x te n d e d W a r ra n ty A d d it io n a l 1 y e a r E x te n d e d W a r ra n ty A d d it io n a l 2 y e a rs E x te n d e d W a r ra n ty A d d it io n a l 3 y e a rs E x te n d e d W a r ra n ty A d d it io n a l 4 y e a rs E x te n d e d W a r ra n ty " L i fe T im e " A d d it io n a l 1 5 y e a rs
TABLE IX Manufacturing SpecialsFactory Factory Identification
0 0 * *
FG * *7 1
F 7 с сM T d dF X • •F3 • • — i
F1b
• •
F 5 • •
F E j iT P • •O X e e01 • • “ I0 2 • •
0 3 • • b0 4 • • 11 5 • • 1
0 0 0 0 • •
32 STR800 Smart Pressure Transmitter
MODEL RESTRICTIONSR e s tr ic t io n
L e t te r
A v a ila b le O n ly W ith N o t A v a ila b le W ith
T a b le | S e le c t io n (s ) T a b le | S e le c t io n (s )
b Select only one option from th is groupd V ila 1 ,2 ,3 ,5 ,6 ,7
с Id _____ 0 , N , В ______
e lb 2 2f IVb F
g IVb _ H , D _
j IVb H Vb _ 1 ,2 ,6 _m IVa B , D , F, Hn IVa А, С , E, G __
У lc ___ E ________
2 le_______ 0 _ ________ 2 ____
_______ 4 ____
3 If 2la 2
4 I 2 0
5VI 0
VIII FG , F7, F X ,O X ,T P ,M T ,F 16 I ___B , D ________ la 2
7 II
__ A F ____ B F __
_ B G __
_ G G __
__ J F _____ J G ___
8 VIII FG , F7
9 IIAA2
_____ A B 2 ______10 II 011 II A
12If A, G , 2
13 II 0II T
VIII FG , F7
15 II
_____ B F ________
_____ B G _____________ B H ________
_____ J F ________
_____ J G ________16 I 217 II __ J A ___
18 II
J J G
J K GJ L G
19la 2
If 2
2 0If A, G , 2
21 I _ 0 0 0
2 2 lc _ E _
FM A p p ro va lsSM is a se rv ice m ark o f FM Global
Hastelloy® is a reg is te red tradem ark o f Haynes International
Monel 400® is a reg is te red tradem ark of Special Metals Corporation.
HART® is a reg is te red tradem ark of HART Comm unication Foundation. FOUNDATION™ Fieldbus is a reg is te red tradem ark o f Fieldbus Foundation.
Teflon® is a reg is te red tradem ark of DuPont.Neobee® is a reg is te red tradem ark o f S tepan Company.
Syltherrrf® 800 is a Tradem ark o f Dow Corning C orporation Klinger® C-4401 is a reg is te red tradem ark of THERMOSEAL, INC
GRAFOIL®is a reg is te red tradem arks o f G ra fTech International Holdings Inc Gylon® 3510 is reg is te red tradem ark o f G arlock Sealing Technologies Tri-C lover Tri-Clamp®is a reg is te red tradem ark o f A lfa -L a va l DC® 200 and DC® 704 a re reg is te red tradem arks o f Dow Corning
STR800 Smart Pressure Transmitter 33
По вопросам продаж и поддержки обращайтесь:Астана +7(7172)727-132, Волгоград (844)278-03-48, Воронеж (473)204-51-73, Екатеринбург (343)384-55-89, Казань (843)206-01-48,
Краснодар (861)203-40-90, Красноярск (391)204-63-61, М осква (495)268-04-70, Н и ж н и й Н овгород (831)429-08-12, Н овосибирск (383)227-86-73, Ростов-на-Дону (863)308-18-15, Самара (846)206-03-16, С анкт-П етербург (812)309-46-40,
Саратов (845)249-38-78, Уфа (347)229-48-12 Единый адрес: hw n@ nt-rt.ru