Pedro Calderón/Guillermo Buenadicha Pedro Calderón/Guillermo Buenadicha SOC Operations Support Group Page 1 XMM-Newton XMM-Newton Status of EPICs Operations Status of EPICs Operations Pedro Calderón Riaño Pedro Calderón Riaño Guillermo Buenadicha Guillermo Buenadicha MALLORCA 05/11/2007 MALLORCA 05/11/2007
Status of EPICs Operations. Pedro Calderón Riaño Guillermo Buenadicha MALLORCA 05/11/2007. Contents. Status of operations since Palermo Pedro Calderon Future activities and open points Guillermo Buenadicha. Overview. Smooth operations, in general MOS2 +32 Volts line drop - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 1
XMM-NewtonXMM-Newton
Status of EPICs OperationsStatus of EPICs Operations
Pedro Calderón Riaño Pedro Calderón Riaño
Guillermo BuenadichaGuillermo Buenadicha
MALLORCA 05/11/2007MALLORCA 05/11/2007
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 2
XMM-NewtonXMM-Newton
ContentsContents
Status of operations since PalermoStatus of operations since PalermoPedro CalderonPedro Calderon
Future activities and open pointsFuture activities and open pointsGuillermo BuenadichaGuillermo Buenadicha
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 3
XMM-NewtonXMM-Newton
OverviewOverview
Smooth operations, in generalSmooth operations, in general MOS2 +32 Volts line dropMOS2 +32 Volts line drop New hot stuff, 3X3, CCD6 checkNew hot stuff, 3X3, CCD6 check New MOS CCD thermal controlNew MOS CCD thermal control Future procedure changesFuture procedure changes
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 4
XMM-NewtonXMM-Newton
Routine OperationsRoutine Operations
RBI clock resync every ~194 daysRBI clock resync every ~194 days– Last on May 29Last on May 29thth, next on December 10, next on December 10thth
Eclipse season fully nominal.Eclipse season fully nominal.– All performed automatically by timeline. All performed automatically by timeline.
A MOS-2 exp in Full Frame 2 Nodes modeA MOS-2 exp in Full Frame 2 Nodes mode– The exposure was erroneously planed. This The exposure was erroneously planed. This
mode is not commissioned.mode is not commissioned.– A TC failed during the reconfiguration after the A TC failed during the reconfiguration after the
end of the exposure. The activity has a flaw at end of the exposure. The activity has a flaw at that point -> to be corrected.that point -> to be corrected.
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 5
XMM-NewtonXMM-Newton
MOS2 +32V drop MOS2 +32V drop
The voltage in the +32V line drop instantaneously The voltage in the +32V line drop instantaneously to 0 volts in the middle of a normal observation, to 0 volts in the middle of a normal observation, the CCD stop generating events, and no other the CCD stop generating events, and no other telemetry parameter showed any change or spike.telemetry parameter showed any change or spike.
After a switch After a switch OFFOFF / switch / switch ONON the instrument the instrument returned to full nominal.returned to full nominal.
Happened a similar incident in MOS-1 on 2002 Happened a similar incident in MOS-1 on 2002 (NCR#105), but never again.(NCR#105), but never again.
MRB with Saclay, Leicester and ESACMRB with Saclay, Leicester and ESAC Suspected a SEU in EMVC electronic ??Suspected a SEU in EMVC electronic ??
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 6
XMM-NewtonXMM-Newton
New Hot StuffNew Hot Stuff
New versions of the MOS Offset TablesNew versions of the MOS Offset Tables– Now at version V12Now at version V12
New versions of the PN Bad Pixel TablesNew versions of the PN Bad Pixel Tables– Fixed the bright 64 column in CCD 11Fixed the bright 64 column in CCD 11
Changes in place since Rev 1389 (July 11Changes in place since Rev 1389 (July 11thth) ) but they were not in full use until Rev 1408 but they were not in full use until Rev 1408 (August 16(August 16thth))
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 7
XMM-NewtonXMM-Newton
MOS 3x3 pointed obsMOS 3x3 pointed obs
Mode tested on March 30Mode tested on March 30thth
Real observation performed in May 2Real observation performed in May 2ndnd on on PSR B0833-45 (rev 1354, OBS_ID PSR B0833-45 (rev 1354, OBS_ID 0510390101, 0510390101, routine calibration obs))
Operations OKOperations OK
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 8
XMM-NewtonXMM-Newton
New ED for CCD6 checksNew ED for CCD6 checks
New ED now availableNew ED now available Last check performed on October 29Last check performed on October 29thth
using the new EDusing the new ED The operation was quick and easyThe operation was quick and easy No changes in results (still full of AFFA hex No changes in results (still full of AFFA hex
events)!!!events)!!!
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 9
XMM-NewtonXMM-Newton
CCD6 imageCCD6 image
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 10
XMM-NewtonXMM-Newton
New MOS CDD thermal controlNew MOS CDD thermal control
Exist only 1 circuit (plus redundant) for the 3 Exist only 1 circuit (plus redundant) for the 3 cameras CCD substitution heaters. If heater are cameras CCD substitution heaters. If heater are ONON for one camera, they are for one camera, they are ONON for all. for all.
If a camera has problems, all cameras are heated If a camera has problems, all cameras are heated => bad science=> bad science
The new idea : avoid heating the CCD of the The new idea : avoid heating the CCD of the cameras that are still workingcameras that are still working
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 11
XMM-NewtonXMM-Newton
New MOS CDD thermal controlNew MOS CDD thermal control
How to do that? How to do that? Allowing the unpowered CCD to cold down to the Allowing the unpowered CCD to cold down to the
minimum tested temperature (-140 degC). minimum tested temperature (-140 degC). That is near to the external radiator temp, so a lot That is near to the external radiator temp, so a lot
of time is needed.of time is needed. Then trigger heaters Then trigger heaters ONON up to operational up to operational
temperature, and switch temperature, and switch OFFOFF again again Heaters will be Heaters will be ONON for limited time, so the impact for limited time, so the impact
in the other cameras is reducedin the other cameras is reduced All this is done via manual procedureAll this is done via manual procedure
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 12
XMM-NewtonXMM-Newton
New MOS CDD thermal controlNew MOS CDD thermal control
-160
-140
-120
-100
-80
-60
-40
-20
0
PNMOS 2MOS 1
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 13
XMM-NewtonXMM-Newton
Future actionsFuture actions
Change of procedures to recover PN from Change of procedures to recover PN from Safe StandbySafe Standby
Now PN never goes normally to SSB, but Now PN never goes normally to SSB, but the procedure should be up to date any the procedure should be up to date any wayway
The idea is switch off all PN, switch on the The idea is switch off all PN, switch on the substitution heaters, and when all substitution heaters, and when all temperatures are good (remember the temperatures are good (remember the problem with the currents when the EPVC problem with the currents when the EPVC is cold, NCR#90), do a full switch on.is cold, NCR#90), do a full switch on.
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 14
XMM-NewtonXMM-Newton
Future activities & open issuesFuture activities & open issues
MOS redundant node readoutMOS redundant node readout MOS and PN, comparison of timing MOS and PN, comparison of timing
fluxflux Rev 1325 Crab timingRev 1325 Crab timing Periodic CCD-6 health checkPeriodic CCD-6 health check PN activities foreseenPN activities foreseen Slew surveySlew survey S2K supportS2K support
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 15
XMM-NewtonXMM-Newton
MOS redundant node readoutMOS redundant node readout
Action pending since TTD@MPE, May 2006Action pending since TTD@MPE, May 2006 The rationale is twofold:The rationale is twofold:
– Assess the capability to react against a HW failure in Assess the capability to react against a HW failure in MOS (similar to RGS-2 case)MOS (similar to RGS-2 case)
– Gain expertise at ESAC building MOS sequencesGain expertise at ESAC building MOS sequences Sequences currently in DB? Sequences currently in DB? Too many…Too many…
– All delivered sequences were kept since launch (and All delivered sequences were kept since launch (and even since FM)even since FM)
– Naming convention has never been consistentNaming convention has never been consistent– Not all of them used In FlightNot all of them used In Flight– However, there are some sequences capable of reverse However, there are some sequences capable of reverse
clocking clocking tests in April 2005, MOS-1 CCD-6tests in April 2005, MOS-1 CCD-6
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 16
XMM-NewtonXMM-Newton
MOS redundant node readoutMOS redundant node readout
How to proceed?How to proceed?– WhenWhen
– It is a task not too urgent, but desirable to be done before T. Abbey runs away
– If current DB sequences are able to do the job, then the design part is not an issue
– Do we aim for Spring 2008?– WhoWho
– Ideally engineers at ESAC and T. Abbey + TBD replacement?
– HowHow– Either developing new sequences from scratch, or
using the DB ones, followed by tests at the Spare and/or on the real unit.
– Last step would be the creation of the DB items (ED’s) to cope with eventual node failure.
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 17
XMM-NewtonXMM-Newton
Timing events PN/M1/M2Timing events PN/M1/M2
Project started by M. Kirsch and John Olaffson (trainee at ESAC).
The idea is to analyze and compare the normalized flux in timing observations among EPIC cameras
Study is still ongoing, some preliminary cases required some support to understand deviations from a nominal ratio– Cases in which MOS-1 deviates (above) from MOS-2 and PN
(possible influence of MOS-1 hot column under weak sources)– Cases in which both MOS deviate (below) from PN, all in
counting. Analysis is required to assess influence of MOS CCD stuck mechanism and the SAS processing of GTI.
Screening of data is ongoing, also the Long Term Archive for HK analysis is being populated.
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 18
XMM-NewtonXMM-Newton
1325 Crab timing…1325 Crab timing…
M. Kirsch reported a M. Kirsch reported a 600 microseconds600 microseconds absolute absolute time deviation in the Crab observation in rev time deviation in the Crab observation in rev 1325.1325.
Nothing abnormal detected in ODF Timing files Nothing abnormal detected in ODF Timing files and no G/S problem found.and no G/S problem found.
A TCS generation problem after the given epoch A TCS generation problem after the given epoch was found at MOC due to old Orbit products.was found at MOC due to old Orbit products.
However, TCS vs. TCX analysis seems OK, shows However, TCS vs. TCX analysis seems OK, shows TCX is independent on the MOC orbit file.TCX is independent on the MOC orbit file.
Mission long TCS vs. TCX analysis is required just Mission long TCS vs. TCX analysis is required just to find different behaviors among files.to find different behaviors among files.
TCX is available and in use for timing observations TCX is available and in use for timing observations through SAS.through SAS.
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 19
XMM-NewtonXMM-Newton
Periodic CCD-6 health checkPeriodic CCD-6 health check
Past operationsPast operations– Tests in April 2005 after CCD failureTests in April 2005 after CCD failure– TTD in MPE May 2006 recommended periodic switch onTTD in MPE May 2006 recommended periodic switch on– Done twice in 2007 (March and October) without Done twice in 2007 (March and October) without
success…success… Is it still worth it? Is it still worth it?
– It is not really time consuming at MOC or SOC, since now It is not really time consuming at MOC or SOC, since now is almost fully automatic.is almost fully automatic.
Can we link this activity to some periodic Can we link this activity to some periodic calibration or diagnostic for MOS?calibration or diagnostic for MOS?– Helps programming the activity regularlyHelps programming the activity regularly
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 20
XMM-NewtonXMM-Newton
PN activities foreseenPN activities foreseen
Past non routine operations since PalermoPast non routine operations since Palermo– Minimal (not to say none!!!)Minimal (not to say none!!!)
Situation seems very stable for the Situation seems very stable for the instrumentinstrument
Any idea or suggestion to:Any idea or suggestion to:– Improve operations?Improve operations?– Exercise operations under failure cases?Exercise operations under failure cases?
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 21
XMM-NewtonXMM-Newton
Slew survey, are we done throughSlew survey, are we done through
Past operationsPast operations– Already reported by Pedro, real target in May.Already reported by Pedro, real target in May.
Future activities and open pointsFuture activities and open points– Offset maps required? Offset maps required? current ones are still current ones are still
theoreticaltheoretical– Calibration items? Calibration items? What would be the What would be the
calibration efforts and type of tests?calibration efforts and type of tests?– Others?Others?
Pedro Calderón/Guillermo BuenadichaPedro Calderón/Guillermo BuenadichaSOC Operations Support Group
Page 22
XMM-NewtonXMM-Newton
S2K in Spare supportS2K in Spare support
Support in the validation of the S2K once it Support in the validation of the S2K once it is integrated in the Spare chain.is integrated in the Spare chain.
Adaptation of DB items to spare (offsets, Adaptation of DB items to spare (offsets, BP’s, clocks, voltage settings).BP’s, clocks, voltage settings).
Define a mirroring mechanism to upgrade Define a mirroring mechanism to upgrade Spare DB in line with future operational Spare DB in line with future operational concepts.concepts.