STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Oct 03, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices
Page 2: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Variable Frequency Drive / Inverter

STARVERT iS50.75 -55kW(1-75HP) 3 phase 200 -230Volts

0.75 -75kW(1-100HP) 3 phase 380 -460Volts

Page 3: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

Overview

Features & Selection Guide

Specifications & Wiring

Terminal Configuration, Keypad & Parameter Navigation

Program Parameter Descriptions

Dimension

Options, DB Resistor & Peripheral Devices

RFI Filters

02

04

06

08

10

18

20

22

Contents

Page 4: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Overview

02

Sensorless, sensored vector controlled iS5, keeps your application in more stable, durable and precise condition.

Options■ Communications Board:•RS-485 •DeviceNet•F-Net•ModBus-RTU•ProfiBus DP•Extended I/O Module

-Sub-A Board: 3 Multi-Function Input3 Multi-Function Output

-Sub-B Board : Encoder Plus InputEncoder Plus Output

-Sub-C Board :3 Multi-Function Input3 Multi-Function OutputAux. Analog Reference Frequency (Isolated)

■ Cable for Remote Keypad Operations■ Dynamic Braking Units for 11~75kW Inverters■ Dynamic Braking Resistors

Application■ Traverse■ Draw■ MMC (Mult Motor Control)■ Converting■ Material Handling■ Web Processing■ Fan/Pump Controls■ Conveyors■ Industrial Washing machine, etc.

Conformity to global standards■ UL and cUL listed for North America■ CE marked for Europe■ Quality process controlled by ISO9001, ISO14000

Standard features■ kW / Voltage Ratings:•0.75~55kW, 200-230VAC, 3 phase •0.75~75kW, 380-480VAC, 3 phase

■ Enclosure: IP00 ~ IP20■ Inverter Type: PWM with IGBT■ Control Method: Sensorless/Sensored Vector ■ 1~15kHz Carrier Frequency (1~8kHz. over 30kW)■ 0~400Hz Output Frequency ■ Removable Keypad (Able to read & write parameters)■ Intelligent Accel/Decel for Trip-Free Operation■ Auto Tuning■ 8 Multi-Function Inputs■ 1 Multi-Function Outputs■ Failure Relay■ Built-in PID Control■ Pre-Set Speeds ■ Wire Operation■ Multi-step Programmable Run Patterns■ Auto Torque Boost■ DC Injection Braking■ Stall Prevention■ Built-In Braking Circuit for 0.75 ~ 7.5kW units

Page 5: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

03

Extended I/O boardsThe iS5 has several additional I/O boards that can be easily mounted into the connection terminal on controlboard. Each I/O board is standardized for a specific I/O requirement.The three main I/O boards are "Sub-board A", "Sub-board B" and "Sub-board C".This helps system engineer to design most adequate and cost effective system using the exactly necessary number of I/Os and functions.It is extendable and changeable in case of system upgrade or change.The control parameters and detailed functions for these boards are not shown until any of them is inserted.

Diversity of communication interfacesThe iS5 provides most popular communication interfaces such as Device Net, Profibus DP, Modbus-RTU, RS485 and F-Net (LS proprietary protocol for LS PLC communication). The "DriveviewTM" software offers Window® based computer monitoring tool through RS-485 interface withgraphic capture, keypad emulator, parameter edit, and text monitor. It is applicable for all LS inverters.

Built-in PID controlIt is valuable in process control. The built-in PID algorithm controls flow, temperature, pressure, etc. through theproportional, integral and differential calculus between the feedback value and reference value in closed loop.The high speed CPU makes the calculation easy and fast.

Sensorless vector controlThe iS5 adopts sensorless vector control algorithm, and it improves not only the torque control characteristics, but the speed controlability in an uncertain condition caused by the load variation as well. The iS5 especially generates strong torque at a low speed range as shown below.

Page 6: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

04

SV008iS5-4SV015iS5-4SV022iS5-4SV037iS5-4SV055iS5-4SV110iS5-4SV150iS5-4SV185iS5-4SV220iS5-4SV300iS5-4SV370iS5-4SV450iS5-4SV550iS5-4SV750iS5-4

SV008iS5-2SV015iS5-2SV022iS5-2SV037iS5-2SV055iS5-2SV110iS5-2SV150iS5-2SV185iS5-2SV220iS5-2SV300iS5-2SV370iS5-2SV450iS5-2SV550iS5-2

0.75 11.5 22.2 33.7 55.5 7.57.5 1011 1515 20

18.5 2522 3030 4037 5045 6055 7575 100

Features & Selection Guide

Auto tuningThe auto tuning algorithm in iS5 sets the motor factors automatically. It brings the traditional commissioning difficulties mainly inlow speed by the load variation and the low torque generation to a settlement.

Optimum acceleration and decelerationTo make a maximum torque during the acceleration and deceleration, so called "trip free" function is acting during accelerationand deceleration. Both of Acceleration and deceleration may cause a trip in case that it is manually programmed. The 32-bitDSP CPU monitors the current transition during the acceleration and deceleration to program an optimum curve that is underthe triptrigering level automatically.

Inverter rating selection guide

Inverter type nomenclature

Application motorKW HP

200~230V 380~460V

SV 008 iS5 -4 #

LS Starvert inverter

008015

.

220

0.75kW1.5kW

.

22kW

iG5iS5iHiV5

iG5 seriesiS5 seriesiH series*iV5 series

-2-4

3 phase 200~230V3 phase 380~480V

* iH inverter has a different designation in kW.

StoppedCH1=2VDC 10:1

CH3=5VDC 10:1

CH4=2VDC 10:1

1s/div[1s/div]NORM:1kS/s

=Trigger=Mode : AUTOType : EDGE CH1Delay : 0.0nsHold Off : MINIMUM

=Record Length=Main : 10kZoom : 500

=Filter=Smoothing : OFFBW : FULL

=Offset=Ch1 : 0.00VCh2 : 0.00VCH3 : 0.00VCH4 : 0.00V

3

StoppedCH1=2VDC 10:1

CH3=5VDC 10:1

CH4=2VDC 10:1

1s/div[1s/div]NORM:1kS/s

=Trigger=Mode : AUTOType : EDGE CH1Delay : 0.0nsHold Off : MINIMUM

=Record Length==Filter=Smoothing : OFFBW : FULL

=Offset=

3

Traditional curve Optimum curve

Trip

Main : 10kZoom : 500

Ch1 : 0.00VCh2 : 0.00VCH3 : 0.00VCH4 : 0.00V

# option built-in

Page 7: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

05

Specifications 200~230V Class (0.75~55kW)Inverter Type (SV_ _ _iS5-_)

Motor Rating*1)

Output ratings

Input ratings

Weight[kg]

[HP][kW]Capacity[kVA]*2)

FLA[A]FrequencyVoltage Voltage Frequency

10.751.95

4.6

008-2 015-2 022-2 037-2 055-2 075-2 110-2 150-2 185-2 220-2 300-2 370-2 450-2 550-22

1.538

4.6

32.24.512

4.8

53.76.116

4.9

7.55.59.124

7.5

107.512.232

7.7

1511

17.546

13.8

2015

22.960

14.3

2518.528.274

19.4

3022

33.588

20

403046122

503755146

604568180

755584220

0 ~ 400 Hz200 ~ 230V*3)

3 phase 200 ~ 230 V (±10%) 50 ~ 60 Hz (±5%)

Specifications 380~480V Class (0.75~75kW)Inverter Type (SV_ _ _iS5-_)

Motor Rating*1)

Output ratings

Input ratings

Weight[kg]

Braking Torque

Cooling methodEnclosure

Braking circuitAverage braking torqueMax.continuousbrakingMax. duty

100%

5seconds

30 (3)%ED

100%

5seconds

30 (2)%ED

100%

5seconds

30 %EDForced air cooling

IP00

150%

Controlled by braking unit*4)

10 %ED

On board

Control

Operation

Control methodFrequency setting resolutionFrequency accuracyV/F ratioOverload capacityTorque boost

Operation methodFrequency settingStart signalMulti-step

Multi-step accel/decel time

Emergency stopJogAuto operationFault reset

Operation status

Fault outputIndicator

Operation function

Inverter trip

Inverter alarmMomentary power lossOperation informationTrip informationAmbient temperatureStorage temperatureAmbient humidityAltitude . VibrationApplication side

Key / terminal / communication operationAnalog : 0 ~ 10V / 4 ~ 20 mA / Additional port for Sub-board (0 ~10V)

forward, reverseUp to 8 speeds can be set (use multi-function terminal)

0 ~ 6,000 sec, up to 8 types can be set and selected for each setting (use the multi- function terminal), Accel/Decel pattern : linear pattern, U pattern, S pattern

Interrupts the output of the inverterJog operation

Operates from internal sequence by setting the multi-function terminal (5way x 8step)Trip status is removed when protective function isactive

Frequency level detection, Overload alarm, stalling, overvoltage, undervoltage, inverter overheating, running, stop, constant speed, exchange inverter to commercial line, speed searching, auto operation step, auto operation sequence

Contact output (30A,30C,30B) - AC250V 1A, DC30V 1AChoose 1 from Output frequency, output current, output voltage, DC voltage (Output voltage: 0 ~ 10V)

DC braking, frequency limit, frequency jump, second function, slip compensation, reverse rotation prevention, auto restart, exchange inverter to commercial line, auto-tuning, PID control

Overvoltage, undervoltage, overcurrent, fuse open, ground fault, inverter overheating, motor overheating, output phase loss, MC fail (over 30kW only), overload protection, external fault 1,2, communication error, loss of speed command, hardware fault, option fault etc.

Stall prevention, overload alarmLess than 15 msec : continuous operation (over 30kW drives excluded), more than 15 msec : auto restart possible

Output frequency, output current, output voltage, frequency value setting, operating speed, DC voltageIndicates the fault when the protection function activates, memorizes up to 5 faults

-10 °C ~ 40 °C-20 °C ~ 65 °C

90 % RH max.(Non condensing)Below 1,000 m˙below 5.9m/sec2 (=0.6g)

No corrosive gas, combustible gas, oil mist, or dust

V/F control, sensorless vector control(selectable), sensored vector controlDigital reference : 0.01 Hz (below 100 Hz), 0.1 Hz (over 100 Hz) Analog reference : 0.03 Hz / 50 Hz

Digital : 0.01% of max. output frequency Analog : 0.1% of max. output frequencyLinear, Square pattern, User V/F

150 % of rated current for 1 min., 200% of rated current for 0.5 sec. (characteristic is inversely proportional to time)Manual torque boost (0 ~ 15 %), Auto torque boost

Optional (Braking unit, resistor)

[HP][kW]Capacity[kVA]*2)

FLA[A]FrequencyVoltage Voltage Frequency

10.751.92.5

4.6

008-4 015-4 022-4 037-4 055-4 075-4 110-4 150-4 185-4 220-4 300-4 370-4 450-4 550-4 750-42

1.534

4.6

32.24.56

4.8

53.76.18

4.9

7.55.59.112

7.5

107.512.216

7.7

1511

18.324

13.8

2015

22.930

14.3

2518.529.739

19.4

3022

34.345

20

40304561

50375675

60456891

755582110

10075100152

0 ~ 400 Hz380 ~ 480V*3)

3 phase 380 ~ 480V (±10%)50 ~ 60 Hz (±5%)

*1) Indicates the maximum applicable capacity when using 4 pole LS standard motor. *2) Rated capacity ( 3*V*I) is based on 220V for 200V class and 440V for 400V class. *3) Maximum output voltage will not be greater than the input voltage. Output voltage less than the input voltage can be set.*4) 0.75 ~ 3.7kW inverter have internal braking resistor inside. 5.5 ~ 75kW inverters need optional braking resistor.

Input

signa

lOu

tput s

ignal

Protective function

DisplayKeypad

Environment

Page 8: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Specifications & Wiring

06

Wiring

DB ResistorDC Bus Choke

DynamicBraking Unit

DB UNIT(OPTION)*4

DB Resistor

MOTOR

U

P1*1 P2*1 N*1

V

W

R

MCCB(OPTION)*4

DC BUS CHOKE(OPTION)*3

3ф230/460V50/60Hz

S

T

G

FX

RX

BX

RST

JOG

P1

P2

P3

CM

VR

30A

30C

30B

AXA

AXC

FM

5G

V1

I

5G

Forward Run/Stop

Reverse Run/Stop

Invert Disable

Fault Reset

Jog

Multi-function Input 1

Multi-function Input 2

Multi-function Input 3

Common Terminal

Potentiometer(1kohm, 1/2W) Shield

Factory Setting‘Speed-L‘‘Speed-M‘‘Speed-H‘

Power supply forspeed signal:+11V, 10mA

Output Frequency Meter(0 - 10V : pulse output)

Fault output relayIess than AC250V, 1AIess than DC30V, 1A

Mult-function output relay1Iess than AC250V, 1AIess than DC30V, 1AFactory setting:‘RUN‘

Speed signal input:0 ~10V

Speed signal input:4 ~ 20mA(250ohm)

Common forVR, V1, I

Speed signal Input *2

+

P N B1 B2

FM

Note) "● " display main circuit terminals, "○ " display control circuit terminals.1. The terminal configuration varies depend on the model name.

`P`terminal is available in 5.5 to 7.5kW inverters. `P1` and `P2` are available in 11 to 75kW inverters.`B1` and `B2` terminals are for braking resister or connection. `P1` and `P2` are for braking unit.

2. Analog speed command can be set by voltage, current and both of them.3. When installing the DC Reactor, the common busbar between P1 and P2 must be removed.4. 0.75 ~ 7.5kW inverters have on-board braking circuit. Braking resistor is only included for 0.75 ~ 3.7kW inverters.

11 ~ 75kW inverters need optional braking unit and resister for dynamic braking.5. Marked as “CM” for over 30kW drives.

Page 9: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

07

Power terminal configuration

Keypad 1. LCD Keypad

Symbol FunctionRSTUVWP

P1P2B1B2NG

AC Line input (3 phase, 200~230 Vac for "-2" units and 380~480 Vac for "-4" units)

3 phase output terminals to motor

Positive DC Bus Terminals, DC Bus Choke (reactor)connection terminals. These terminals are available for 5.5 to 7.5kW inverter with optional DB unit when an application need braking torque over 30% EDPositive DC Bus Terminals, DC Bus Choke (reactor)connection terminals. These terminals are available for 11 to 22kW inverter with optional DB unit. These terminal are shorted when DB unit is not applied.Dynamic braking resistor connection terminals. These terminals are available for 0.75 to 3.7kW inverters in order to connect an external braking resistor.

Negative DC Bus terminalChassis ground (The ground terminal ("G") may be located on heat sink instead of terminal strip depend on the model type)

Control terminal configurationTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeTypeType

Starting ContactFunctionSelection

Analog/Digital

Pulse

Contact

RS232

Type SymbolP1, P2, P3

FXRX

JOGBX

RSTCMNC VRV1I

5GFM

30A,30C,30B

AXA,AXCCN3

NameMulti function input 1,2,3Forward run commandReverse run commandJog frequency reference Emergency stop

Fault resetSequence common-Frequency setting power (+12V)Frequency reference (Voltage)Frequency reference (Current)Frequency setting common terminalAnalog/digital output(For external monitoring)

Fault contact output

Multi-function outputCommunication port

DescriptionUsed for multi function input. Factory default is set to step frequency 1, 2, 3.Forward run when closed and stop when open.Reverse run when closed and stop when open.Runs at jog frequency when the jog signal is ON. The direction is set by the FX (or BX) signal.When the BX signal is ON, the output of the inverter is cut off. When the motor uses an electrical brake to stop, BX is used to cut off the output signal. When the BX signal, which does not cut off by latching, is OFF and the FX signal (or the RX signal) is ON, the motor keeps running, so be cautious.Used to release the protective status when the protective circuit is active.Used for the common terminal for contact input terminals.Not used.Used as power for the analog frequency setting. Maximum output is +12V, 100mA.Used for frequency reference and uses 0-10V for input. Input resistance is 20 k1Used for frequency reference and uses DC 4-20mA for input. Input resistance is 2501Common terminal for the analog frequency reference signal and the FM (for monitoring).Outputs one of the followings: output frequency, output current, output voltage, DC link voltage. Factory default is set to output frequency. Maximum output voltage and output current is 0-12V, 1mA. Output frequency is set to 500Hz.Activates when the protective function is operating. AC250V 1A or less, DC30V 1A or lessFault : 30A-30C short (30B-30C open)Normal : 30B-30C short (30A-30C open)Use after defining the multi-function output terminal. AC250V 1A or less, DC30V 1A or less.Use the keypad connector. Use the keypad connector for RS232 communication. Disconnect the keypad and connect the RS232-RS485 converter for RS485 communication.

Inpu

t sig

nal

Outp

ut si

gnal

Comm

.

Key/LED DescriptionMODEPROGENTUP

DOWNSHIFT/ESC

REWSTOP/RESET

FWDREV

STOP/RESETFWD

NameMode keyProgram keyEnter keyUp keyDown keyShift keyEscape keyReverse keyStop keyReset keyForward keyReverse runStop/resetForward run

The mode button moves you through the seven program groups : DRV, FUN1, FUN2, I/O, (EXT), (COM) and APP.The program button is used to go into programming mode to change data.The enter button is used to enter changed parameters.

The up and down arrows are used to move through and change data.

The button is used to move cursor across the display in a programming mode.This button is used to move the program code to DRV00 from any program code.The reverse run button is used to run the motor in reverse direction.The stop button is used to the drive from running.The reset button is used to reset faults.The forward run button is used to run the motor in forward direction.The LED blinks when th inverter accels or decels.The LED blinks when there is a fault.The LED blinks when the inverter accels or decels.

▲▼

2. LED Keypad (7-segment)Encoder knob

SETSHIFT/ESC

STOP/RESET

RUNSET

STOP/RESETRUNDRVFU1FU2I/O

EXTI/O+EXT

I/O+EXT+FU2

Encoder Knob

Set keyShift keyEscape keyStop keyReset keyRun keySetting statusStop/Fault statusRun statusDrive groupFunction1 groupFunction2 groupI/O groupSub-board groupOption-board groupApplication group

This is used to move you through seven parameter groups and parameter codes. Also, used to change data by rotating knob.This is used to go into program mode to change data and to enter the changed data.This is used to go into program mode to change data and to enter the changed data.This button is used to move cursor across the display in a programming mode.This is used to stop the inverter from running.The reset button is used to reset faults.This is used to run the inverter. The motor direction is set in DRV13.It blinks in setting mode.The LED is lit in Stop status and blinks in fault status.The LED is lit in Run status and blinks in fault status.It blinks in drive group.It blinks in Function1 group.It blinks in Function2 group.It blinks in I/O group.It blinks in Sub-board group.It blinks in Option board group.It blinks in Application group.

MODE PROG

LC-200

ENT

FWDREV

SHIFTESC

STOPRESET

PROGENT

LC-200

RUN

SHIFTESC

STOPRESET

DRV FU1 FU2 I / O EXT

Page 10: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Terminal Configuration, Keypad & Parameter Navigation

08

Parameter group

Parameter navigation

DriveFunction 1Function 2Input / OutputExternal boardCommunicationApplication

Parameter group LCD keypadDRVFU1

FUN2I/O

EXTCOMAPP

7-segment keypadDRV LED is lit

FU1 is litFU2 is litI/O is lit

EXT is litI/O + EXT are lit

I/O + EXT + FU2 are lit

DescriptionCommand frequency, accel/decel time, etc. Basic parameters.Max. frequency, amount of torque boost, etc. Basic function related parameters.Frequency jumps, max./min. limit of frequency etc. Application function related parameters.Multi function terminal setting, auto operation etc. Parameter needed for sequence operation.Displayed when sub-board is installed.Displayed when option board is installed.Specific application related parameters.

1. LCD Keypad

MODE

MODE

MODE

MODE

MODE

MODE

MODE

DRV T/K 0.0A00 STP 60.00Hz

FU1 Jump coad00 1

FU2 Jump coad00 30

I/O Jump coad00 1

DRV Acc. time01 10.0sec

FU1 Run prohibit03 None

FU2 last trip-101 ______

I/O V1 filter01 10ms

MODE MODE MODE MODE

DRV Dc. time02 20.0sec

FU1 Acc.Pattern05 Linear

FU2 last trip-202 ______

I/O V1voltx102 0.00V

MODE MODE MODE MODE

DRV Drive mode03 Fx/Rx-1

FU1 Dec.Pattern06 Linear

FU2 last trip-3�03 ______

I/O V1 freqy103 0.00Hz

MODE MODE MODE MODE

DRV Freq mode04 Keypad-1

FU1 Stop mode07 Decel

FU2 last trip-404 ______

I/O V1 voltx204 10.00V

MODE MODE MODE MODE

DRV Step freq-105 10.00Hz

FU1 DcStvalue08 50%

FU2 last trip-505 ______

I/O V1 freq y203 60.00Hz

MODE

DRV Fault12 - - - - - - - - - - -

MODE

FU1 Stall Level60 150%

MODE

FU2 Para.lock94 0

MODE

I/O Way1/2D60 Forward

MODE

Drive group Function1 group Function2 group I / O group

Page 11: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

09

2. LED keypad (7-segment)

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

DRV FU1 FU2 I/O EXT

SET

SET

SET

SET

ESC

FU 1

FU 2

I/O

DRV

SET

SET

Operation methodOperation method Function Function setting

Keypad

Terminal

Keypad and Terminal

Option board

Run/Stop command and frequency are set only through the keypad.Closing FX or RX terminal performs Run/Stop. Frequency reference isset through keypadRun/Stop command and frequency are set only through the terminal.Closing FX or RX terminal performs Run/Stop. Frequency reference is set through V1 or I or V1+I terminal.

Closing Fx or RX terminal performs Run/Stop. Frequency reference is set through keypad.Operation using additional sub or option board.Sub board : SUB-A, SUB B, .. SUB-HOption board : Device Net, Synchro, Profibus DP, Digital-in, RS485, Modbus-RTU

DRV 03 : KeypadDRV 04 : Keypad

DRV 03 : Fx/Rx-1 or -2DRV 04 : V1 or I or V1+IDRV 03 : Keypad-1 or -2DRV 04 : V1 or I or V1+IDRV 03 : Fx/Rx-1 or -2DRV 04 : Keypad-1 or -2

Page 12: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Program Parameter Descriptions

10

1. Drive Group [DRV]

Program parameter descriptions

Code Description UnitsLCD 7-segmentKeypad Display Setting Range Factory Adjustable

LCD 7-segment Default during run

DRV-00

DRV-01DRV-02DRV-03

DRV-04

DRV-05DRV-06DRV-07DRV-08DRV-09DRV-10DRV-11DRV-12DRV-13DRV-14DRV-15DRV-20DRV-21DRV-22DRV-23DRV-24DRV-25

Output Frequency or Reference Frequency. Output Current (LCD)Acceleration TimeDeceleration TimeDrive Mode (Run/Stop method)

Frequency Mode (Freq. setting method)

Step Frequency 1Step Frequency 2Step Frequency 3Output CurrentMotor SpeedDC link VoltageUser Display selectionFault DisplayMotor Direction setCommand/output frequencyCommand/feedback frequencyFU1 Group selectionFU2 Group selectionI/O Group selectionEXT Group selectionCOM Group selectionAPP Group selection

Cmd.freq

Acc.timeDec.time

Drive mode

Freq mode

Step freq-1Step freq-2Step freq-3

CurrentSpeed

DC link VtgUser disp

FaultNot displayed Tar/Out Freq.Ref/Fdb Freq.Not displayed

F or r (DRV-13)

0 I0203

04

0506070809I 0I II 2I 3I 4I 5202 I22232425

0.01

0.10.11

1

0.01----------------

0.00 [Hz]

10.0 [sec]20.0 [sec]1 (Fx/Rx-1)

0 (keypad-1)

10.00 [Hz] 20.00 [Hz] 30.00 [Hz]

# [A]# [rpm]

# [V]-

None nOn0

# [Hz]# [Hz]

111111

Yes

YesYesNo

No

Yes-----

Yes--

YesYesYesYesYesYesYesYes

KeypadFx/Rx-1Fx/Rx-2

Keypad-1Keypad-2

V1I

V1+I

01201234

-Not available

Not available

-0 [Forward]1 [reverse]

Press[Prog/ENT] key

0 to FU1-20 (Max.freq)

0 to 60000 to 6000

FU1-22 to Fu1-20(Starting freq to Max. freq)The load current in RMSThe motor speed in rpm

The DC link voltage inside inverterSelected in FU-73 (User disp)

Command/output frequencyCommand/feedback frequency

2. Function 1 Group [FU1]FU1-00FU1-03

FU1-05

FU1-06

FU1-07[1]

FU1-08FU1-09FU1-10FU1-11FU1-12FU1-13FU1-20FU1-21FU1-22FU123[2]

FU1-24FU1-25FU1-26

FU1-27FU1-28FU1-29[3]

FU1-30FU1-31FU1-32FU1-33FU1-34FU1-35FU1-36FU1-37FU1-38FU1-39FU150[4]

aJump to desired code #Run Prevention

Acceleration Pattern

Deceleration Pattern

Stop Mode

DC Injection Braking FrequencyDC Injection Braking On-delayDC Injection Braking VoltageDC Injection Braking TimeStartingDC Injection Braking VoltageStartingDC Injection Braking TimeMaximum FrequencyBase FrequencyStarting FrequencyFrequency Limit selection

Low Limit FrequencyHigh Limit Frequency Manual/Auto Torque Boost selection

Torque Boost in Forward DirectionTorque Boost in Reverse DirectionVolts/Hz Pattern

User V/F - Frequency 1User V/F - Voltage 1User V/F - Frequency 2User V/F - Voltage 2User V/F - Frequency 3User V/F - Voltage 3User V/F - Frequency 4User V/F - Voltage 4Output Voltage AdjustmentEnergy Save Level F39Electronic Thermal selection

Jump codeRun Prev.

Acc.pattern

Dec.pattern

Stop mode

DCBr freqDCBlk timeDcbr valueDcBr timeDcSt valueDcSt timeMax freqBase freqStart freqFreq limit

F-limit LoF-limit Hi

Torque booth

Fwd boothRev boothV/F pattern

User freq 1User volt 1User freq 2User volt 2User freq 3User volt 3User freq 4User volt 4Volt control

Energy saveETH select

Not displayed3

5

6

7

89I 0I II 2I 3202 I2223

242526

272829

303I323334353637383950

11

1

1

1

0.010.01

10.11

0.10.010.010.01

1

0.010.01

1

0.011

0.011

0.011

0.011

10 (None)

0 (Linear)

0 (Linear)

0 (Decel)

5.00 [Hz]0.1 [sec]50 [%]

1.0 [sec]50 [%]

0.0 [sec]60.00 [Hz]60.00 [Hz] 0.50 [Hz]

0 (No)

0.50[Hz]60.00[Hz]0 (Manual)

2.0 [%]2.0 [%]

0 (Linear)

15 [Hz]25 [%]

30.00 [Hz]50 [%]45 [Hz] 75 [%]

60.00 [Hz]100 [%]

100.0 [%]0 [%]0 (No)

YesNo

No

No

No

NoNoNoNoNoNoNoNoNoNo

NoNoNo

NoNoNo

NoNoNoNoNoNoNoNoNoYesYes

1 to 99None

Forward PrveReverse Prve

LinerS-curveU-curveMinimumOptimum

LinerS-curveU-curveMinimumOptimum

DecelDC-brakeFree-run

Not available0120123401234012

NoYes

01

FU1-22 to 60 [Hz]0 to 60 [sec]0 to 200 [sec]0 to 60 [sec]0 to 200 [sec]0 to 60 [sec]40 to 400[Hz]30 to FU1-200.01 to 10[Hz]

FU1-22 to Fu1-25FU1-22 to Fu1-25

ManualAuto

01

0 to 15 [%]0 to 15 [%]

LinearSquare

User V/F

012

0 to FU1-200 to 100 [%]0 to FU1-200 to 100 [%]0 to FU1-200 to 100 [%]0 to FU1-200 to 100 [%]

40 to 110.0 [%]0 to 30 [%]

01

NoYes

Page 13: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

11

2. Function 1 Group [FU1]Code Description UnitsLCD 7-segment

Keypad Display Setting Range Factory AdjustableLCD 7-segment Default during run

FU1-51FU1-52FU1-53FU1-54FU1-55FU1-56

FU1-57FU1-58FU1-59FU1-60FU1-99

Electronic Thermal Level for 1 minuteElectronic Thermal Level for continuousElectronic Thermal Characteristic selection (Motor type)Overload Warning LevelOverload Warning Hold TimeOverload Trip selection

Overload Trip LevelOverload Trip Delay TimeStall Prevention Mode selectionStall Prevention LevelReturn Code

ETH 1minETH contMotor type

OL levelOL time

OLT select

OLT levelOLT timeStall prev.Stall level

Not display

5 I5253

545556

5758596099

111

10.11

11bit11

150 [%]100 [%]

0 (self-cool)

150 [%]10.0 [sec]1 (Yes)

180 [%]60.0 [sec]

000150 [%]

1

YesYesYes

YesYesYes

YesYesNoNoYes

self-coolForced-coo

01

FU1-52 to 200 [%]50 to FU1-51

NoYes

01

30 to 150 [%]0 to 30 [sec]

Not available [PROG/ENT]or

[SHIFT/ESC]

30 to 150 [%]0 to 60 [sec]

000 to 111 (bit set)30 to 150 [%]

3. Function 2Group [FU2]Code Description UnitsLCD 7-segment

Keypad Display Setting Range Factory AdjustableLCD 7-segment Default during run

FU2-00 FU2-01FU2-02FU2-03FU2-04FU2-05FU2-06

FU2-07

FU2-08FU2-10[5]

FU2-11FU2-12FU2-13FU2-14FU2-15FU2-16FU2-17FU2-18FU2-19FU2-20

FU2-21

FU2-22FU2-23FU2-24FU2-25FU2-26FU2-27FU2-30

FU2-31FU2-32FU2-33FU2-34FU2-36FU2-37FU2-38FU2-39

FU2-40

Jump to desired code #Previous Fault History 1Previous Fault History 2Previous Fault History 3Previous Fault History 4Previous Fault History 5Erase Fault History

Dwell Frequency

Dwell TimeFrequency Jump selection

Jump Frequency 1 Low Jump Frequency 1 HighJump Frequency 2 Low Jump Frequency 2 HighJump Frequency 3 Low Jump Frequency 3 HighStarting rate of S curveEnding rate of curveInput/Output Phase Loss ProtectionPower ON Start selection

Restart after Fault Reset

Speed Search selectionCurrent Limit Level during Speed SearchP Gain during Speed SearchI Gain during speed searchNumber of Auto Restart AttemptDelay Time before Auto RestartRated Motor selection

Number of Motor PoleRated Motor SlipRated Motor Current in RMSNo Load Motor Current in RMSMotor EfficiencyLoad InertiaCarrier FrequencyControl Mode selection

Auto tuning selection

Jump codeLast trip-1Last trip-2Last trip-3Last trip-4Last trip-5Erase trips

Dwell freq

Dwell timeJump Freq

Jump lo 1Jump Hi 1Jump lo 2Jump Hi 2Jump lo 3Jump Hi 3Start CurveEnd curveTrip selectPower-on run

RST restart

Speed SearchSS Sup-CurrSS P-gainSS I-gainRetrynumberRetry DelayMotor select

Pole numberRated-SlipRated-CurrNoload-CurrEfficiencyInertia rateCarrier freqControl mode

Auto tuning

Not displayedI23456

7

8I 0

I II 2I 3I 4I 5I 6I 9I 9I 920

2 I

22232425262730

3 I32333436373840

4 I

1

1

1

0.01

0.11

0.010.010.010.010.010.01

11-1

-1111

0.11

10.01

111111

1

300 (None)

0 (No)

5.00 [Hz]

0.0 [sec]0 (No)

10.00 [Hz]15.00 [Hz]20.00 [Hz]25.00 [Hz]30.00 [Hz]35.00 [Hz]

40 [%]40 [%]

000 (No)

0 (No)

0000100 [%]

1001000

01.0 [sec]

[6]

4[7]

05 [kHz]0 [V/F]

0 (No)

Yes

-

Yes

No

NoNo

NoNoNoNoNoNoNoNoYesYes

Yes

NoYesYesYesYesYesNo

NoNoNoNoNoNoYesNo

No

1 to 99

NoYes

NoYes

NoYesNoYes

0.75kW1.5kW2.2kW3.7kW5.5kW7.5kW11.0kW15.0kW18.5kW22.0kW30kW37kW45kW55kW75kW

V/FSlip comp

PIDSensorless

NoYes

Not available

01

01

0101

01234567891011121314

012301

By pressing[PROG]and[▲ ]key, the frequency, current, operation

status at the time of faultcan be seen.

FU1-22 to FU1-20(starting freq.to Max.freq.)

0 to 10 [sec]

Fu1-22 to FU2-12Fu1-11 to FU2-20Fu1-22 to FU2-14Fu1-13 to FU2-20Fu1-22 to FU2-16Fu1-15 to FU2-20

0 - 100 [%]0 - 100 [%]

00 to 11 (bit set)

0000 to 1111 (bit set)80 to 200 [%]0 to 300000 to 30000

0 to 100 to 60 [sec]

2 to 120 to 10 [Hz]1 to 200 [A]

0.5 to 200 [A]70 to 100 [%]

0 to 1[8] 1 to 15 [kHz]

Page 14: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Program Parameter Descriptions

12

3. Function 2Group [FU2]Code Description UnitsLCD 7-segment

Keypad Display Setting Range Factory AdjustableLCD 7-segment Default during run

FU2-41FU2-42FU2-43FU2-44FU2-45FU2-46FU2-47

FU2-48FU2-49

FU2-50

FU2-51[10]

FU2-52FU2-53FU2-54FU2-55FU2-56FU2-57

FU2-58FU2-59FU2-60FU2-69FU2-70

FU2-71

FU2-72FU2-73

FU2-74FU2-75

FU2-76[11]FU2-79FU2-81[12]FU2-82FU2-83FU2-84

FU2-85FU2-86FU2-87FU2-88FU2-89FU2-90FU2-91

FU2-92

FU2-93

FU2-94FU2-99

Stator resistanceLeakage inductanceStator inductanceRotor time constant P gain for sensorless modeI gain for sensorless mode PID operation selection

PID feed forward gainPID Reference mode selection

PID Output direction selection

PID feedback Signal selection

P Gain for PID ControlI Gain for PID ControlD Gain for PID ControlLimit (+) Frequency for PID ControlLimit (-) Frequency for PID ControlPID Output inverter

PID Output gain scalePID P2 scaleP gain scaleSpeed Acc/dec turning pointReference Frequency for Accel and Decel

Accel/Decel Time scale

Power On DisplayUser Display selection

Gain for Motor Speed DisplayDB (Dynamic Braking) Resistor Mode selection

Duty of Dynamic Braking ResistorSoftware Version2nd Acceleration Time2nd Deceleration Time2nd Base Frequency2nd Pattern

2nd Forward Torque Boost2nd Reverse Torque Boost2nd Stall Prevention Level2nd Electronic Thermal Level for 1 minute2nd Electronic Thermal Level for continuous2nd Rated Motor CurrentRead Parameters into Keypad from inverter

Write Parameter to inverter from Keypad

Initialize Parameter

Parameter Write ProtectionReturn Code

RsLsigmaLsTrSL P-gainSL I-gainProc PI mode

PID F- gainPID Ref

PID Ref Mode

PID F/B

PID P-gainPID I-gainPID D-gainPID+limitPID-limitPID Out Inv.

PID Out ScalePID P2-gainP-gain Scale

Acc/Dec freq

Time scale

PowerOn dispUser disp

RPM factorDB mode

DB %EDS/W version2nd Acc time2nd Dec time2nd Basefreq2nd V/F

2nd F-boost2nd R-boost2nd Stall2nd ETH 1min2ndETH cont2nd R-CurrPara. Read

Para. Write

Para. Init

Para. LockNot display

41424344454647

4849

50

51

525354555657

5859606970

7 I

7273

7475

76798 I828384

8586878889909 I

92

93

9499

0.0010.0010.001

1111

0.1[%]1

111

11

0.010.01

10.1 [%]

0.1 [%]0.1 [%]

1

1

1

11

11

-0.10.10.01

10.1

0.1111

0.111

1

1

1-

Decided depending on motor capacityDecided depending on motor capacityDecided depending on motor capacityDecided depending on motor capacity

10001000

0

0.0[%]0 (Freq mode)

0 (Ramp freq)

0 (I)

300.0 [%]30.0 [sec]

0 (No)60.00 [Hz]60.00 [Hz]

0 (No)

100.0 [%]100.0 [%]100.0 [%]

0 (Max.frq)

0 (0.01[sec])

00 (Voltage)

100 [%]1 (Int.DB-R)

10 [%]Ver.1.055.0 [sec]10.0 [sec]60.0 [Hz]0 (Liner)

2.0 [%]2.0 [%]150 [%]150 [%]100 [%]3.6 [A]0 (No)

0 (No)

0 (No)

01

NoNoNoYesYesNoNo

YesNo

No

No

YesYesYesYesNoNo

NoNoYes

Yes

Yes

Yes

YesYes

-YesYesNoNoNo

NoNoYesYesNoNoNo

No

Yes

YesYes

Decided depending on motor capacityDecided depending on motor capacityDecided depending on motor capacityDecided depending on motor capacity

0 to 32760 to 3276

0 (No)1 (Yes)

0~999.9[%]

0 to 999.9 [%]0to 32.0 [sec]

0 to 999.9 [msec]0 to FU1-200 to FU1-20

0.1 to 999.9 [%]0.0 to 999.9 [%]0.0 to 100 [%]

0 to 12

1 to 1000 [%]

0 to 30 [%]ver.1.05

0 to 6000 [sec]0 to 6000 [sec]30 to FU1-20

0 to 15 [%]0 to 15 [%]

30 to 150 [%]FU2-89 to 200 [%]

50 to FU2-88 (maximum150%)1 to 200 [A]

0 to 255

4. Input / Output [I/O]Code Description UnitsLCD 7-segment

Keypad Display Setting Range Factory AdjustableLCD 7-segment Default during run

I/O-00I/O-01I/O-02I/O-03

I/O-04I/O-05

Jump to desired code#Filtering Time Constant for V1 Signal InputV1 Input Minimum VoltageFrequency corresponding to V1 Input Minimum Voltage V1 Input Maximum VoltageFrequency corresponding to V1 Input Minimum Voltage

JumpV1 Filter

V1 volt x1V1 freq y1

V1 volt x2V1 freq y2

Not DisplayedI23

45

11

0.010.01

0.010.01

110 [ms]0.00 [V]0.00 [Hz]

10.00 [V]60.00 [Hz]

YesYesYesYes

YesYes

1 to 99 Not available0 to 9999 [ms]

0 to 10 [V]0 to FU1-20 (Max.freq)

0 to 10 [V]0 to FU1-20 (Max.freq)

Freq. ModeKeypad-1Keypad-2

V1I

V1+IRamp freqTarget freq

IV1V2

NoYes

Max freqDelta freq0.01 [sec]0.1 [sec]1 [sec]

VoltageWatt

Torque

NoneInt. DB-RExt. DB-R

LinerSquare

User V/F

NoYesNoYesNo

All groupDRVFU1FU2I/O

EXT

Not available

01234501012

01

01012

012

012

012

01010123456

[PROG/ENT]or

[SHIFT/ESC]

Page 15: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

13

4. Input / Output [I/O]

Code Description UnitsLCD 7-segmentKeypad Display Setting Range Factory Adjustable

LCD 7-segment Default during run

I/O-06I/O-07I/O-08

I/O-09I/O-10

I/O-11

I/O-12

I/O-13I/O-14I/O-15I/O-16I/O-17

I/O-20I/O-21I/O-22I/O-23I/O-24I/O-25I/O-26I/O-27I/O-28I/O-29I/O-30I/O-31I/O-32I/O-33I/O-34I/O-35I/O-36I/O-37I/O-38I/O-40

I/O-41I/O-42I/O-43I/O-44

Filtering Time Constant for V1 Signal Input Input Minimum CurrentFrequency corresponding to V1 InputMinimum VoltageI Input Minimum CurrentFrequency corresponding to I Input Maximum CurrentCriteria for Analog Input Signal Loss

Multi-function Input Terminal `P1`define

Multi-function Input Terminal `P2`defineMulti-function Input Terminal `P3`defineTerminal Input StatusTerminal Output StatusFiltering Time Constant for Multi-functionInput TerminalJog Frequency settingStep Frequency 4Step Frequency 5Step Frequency 6Step Frequency 7Acceleration Time 1 for Step FrequencyDeceleration Time 1 for Step FrequencyAcceleration Time 2Deceleration Time 2Acceleration Time 3Deceleration Time 3Acceleration Time 4Deceleration Time 4Acceleration Time 5Deceleration Time 5Acceleration Time 6Deceleration Time 6Acceleration Time 7Deceleration Time 7FM (Frequency Meter) Output selection

FM Output AdjustmentFrequency Detection LevelFrequency Detection BandwidthMulti-function AuxiliaryContact Output define(AXA, AXC)

I filterV1 curr x1V1 freq y1

V1 curr x2I freq y2

Wire broken

P1 define

P2 defineP3 defineIn statusOut statusTi Fit Num

Jog freqStep freq-4Step freq-5Step freq-6Step freq-7Acc time-1Dec time-1Acc time-2Dec time-2Acc time-3Dec time-3Acc time-4Dec time-4Acc time-5Dec time-5Acc time-6Dec time-6Acc time-7Dec time-7FM mode

FM adjustFDT freqFDT bandAux mode

678

9I0

I I

I2

I3I4I5I6I7

202I2223242526272829303 I3233343536373840

4 I424344

10.010.01

0.010.01

1

1

11--1

0.01

0.10.10.10.10.10.10.10.10.10.10.10.10.10.11

10.010.01

1

10 [ms]4.00 [mA]0.00 [Hz]

20.00 [mA]60.00 [Hz]

0 (None)

0 (Speed-L)

1 (Speed-M)2 (Speed-H)000000000

000015

10.00 [Hz]40.00 [Hz]50.00 [Hz]40.00 [Hz]30.00 [Hz]20.0 [sec]20.0 [sec]30.0 [sec]30.0 [sec]40.0 [sec]40.0 [sec]50.0 [sec]50.0 [sec]40.0 [sec]40.0 [sec]30.0 [sec]30.0 [sec]20.0 [sec]20.0 [sec]

0 (Frequency)

100 [%]30.00 [Hz]10.00 [Hz]12 (run)

YesYesYes

YesYes

Yes

Yes

YesYes

--

Yes

YesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYes

YesYesYesYes

0 to 9999 [ms]0 to20 [ms]

0 to FU1-20 (Max.freq)

0 to20 [ms]0 to FU1-20

Same as aboveSame as above

000000000 to 111111110000 to 1111

2 to 50

FU1-22 to FU1-20 (Starting freq toMax, freq)

0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]0 to 6000 [sec]

10 to 200 [%]0 to FU1-200 to FU1-20

Nonehalf x1

below x1Speed -LSpeed -MSpeed -HXCEL-LXCEL-MXCEL-HDc-brake2nd FuncExchange-Reverse-

UpDown3-Wire

Ext Trip-AExt Trip-B-Reverse-Open-loopMain-DriveAnalog holdXCEL stop-Reverse-

SEQ-LSEQ-MSEQ-HManualGo step

Hold stepTrvOff. Lo

Trv Off. HiInterlock1Interlock2Interlock3Interlock4

FrequencyCurrentVoltage

DC link voltage

FDT-1FDT-2FDT-3FDT-4FDT-5

OLIOLStallOV

01201234567891011121314151617181920212223242526272829303132

0123

012345678

Page 16: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Program Parameter Descriptions

14

4. Input / Output [I/O]Code Description UnitsLCD 7-segment

Keypad Display Setting Range Factory AdjustableLCD 7-segment Default during run

I/O-44

I/O-45I/O-46[13]I/O-47

I/O-48

I/O-49I/O-50

I/O-51I/O-52I/O-53[14]I/O-54I/O-55I/O-56

I/O-57I/O-58I/O-59I/O-60

I/O-99

Fault Output Relay setting (30A,30B,30C)Inverter NumberBaud Rate

Operation selection at loss of Freq. Reference

Waiting Time after Loss of Freq. ReferenceAuto (Sequence)Operation selection

Sequence Number selectionThe Number of steps of Sequence Number#1st Step Frequency of SequenceTransient Time to 1st Step of SequenceSteady Speed Time at 1st Step of SequenceMotor Direction of 1st Step of Sequence 1

1st Step of Frequency of Sequence 2Transient Time to 1st Step of Sequence 2Steady Speed Time at 1st Step of Sequence 2Motor Direction of 1st Step of Sequence 2

Return Code

Relay modeInv No.Baud rate

lost command

Time outAuto mode

Seq seletStep numberSeq1/1FSeq1/1TSeq1/1SSeq1/1D

Seq1/1FSeq1/1TSeq1/1SSeq1/1D

Not Disp layed

454647

48

4950

5 I5253545556

57585960

99

-11

1

0.11

11

0.010.10.1-

0.010.10.11

1

010 [bit]1

3 (9600bps)

0 (None)

0.1 [sec]

0 (None)12

11.00 [Hz]1.1 [sec]1.1 [sec]

1 (Forward)21.00 [Hz]1.1 [sec]1.1 [sec]

1 (Forward)1

YesYesYes

Yes

YesNo

YesYesYesYesYesYes

YesYesYesYes

Yes

000 to 111 (bit set)1 to 32

0.1 to 120[sec]

1 to 51 to 8

0.01 to FU1-20 (Max.freq.)0.1 to 6000 [sec]0.1 to 6000 [sec]

0.01 to FU1-20 (Max.freq.)0.1 to 6000 [sec]0.1 to 6000 [sec]

LVOHLost

CommandRunStop

1200bps2400bps4800bps9600bps19200bps

NoneFreerun

Stop

NoneAuto-AAuto-B

ReverseForward

ReverseForward

Not available

910111213

01234012

012

01

01

[PROG/ENT]or

[SHIFT/ESC]

5. External Group [EXT]

Code Description UnitsLCD 7-segmentKeypad Display Setting Range Factory Adjustable

LCD 7-segment Default during run

EXT-00EXT-01

EXT-02

Jump to desired code #Sub board Type display

Multi-function Input Terminal `P4`define

Jump code

Sub B/C

Not displayedI

2

11

1

10 (None)

3 (XCEL-L)

YesAutomatically

set

Yes

0 to 99None

SUB-ASUB-BSUB-CSUB-DSUB-ESUB-FSUB-GSUB-H

Speed -LSpeed -MSpeed -HXCEL-LXCEL-MXCEL-HDc-brake2nd FuncExchange-Reversed-

UpDown3-Wire

Ext Trip-AExt Trip-B-Reversed-Open-loopMain-DriveAnalog holdXCEL stop-Reversed-

SEQ-LSEQ-MSEQ-HManualGo step

Hold stepTrv Off. LoTrv Off. Hi

Not available012345678012345678910111213141516171819202122232425262728

EXT group appears only when the corresponding option boards are installed.

Page 17: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

15

5. External Group [EXT]

Code Description UnitsLCD 7-segmentKeypad Display Setting Range Factory Adjustable

LCD 7-segment Default during run

EXT-02

EXT-03EXT-04EXT-05

EXT-06EXT-07EXT-08

EXT-09EXT-10

EXT-14

EXT-15

EXT-16EXT-17EXT-18EXT-19

EXT-20EXT-21

EXT-22EXT-23EXT-24EXT-30

EXT-31EXT-32EXT-34

EXT-35EXT-40

EXT-41EXT-42

EXT-43EXT-99

Multi-function Input Terminal `P5`defineMulti-function Input Terminal `P6`defineV2 Mode selection

Filtering Time Constant for V2 Signal InputV2 Input Minimum VoltageFrequency corresponding to V2 Input Minimum VoltageV2 Input Maximum VoltageFrequency corresponding to V2 InputMaximum VoltageUsage of Pulse Input Signal

Pulse Input Signal selection

Encoder Pulse NumberFiltering Time Constant for Pulse Input Signal Pulse Input Minimum FrequencyFrequency Output corresponding to PulseInput Minimum FrequencyPulse Input Maximum FrequencyFrequency Output corresponding to PulseInput Maximum FrequencyP-Gain for `Sub-B`I-Gain for `Sub-B`Slip P-Gain for Frequency `Sub-B`boardMulti-function Output Terminal `Q1` define

Multi-function Output Terminal `Q2` defineMulti-function Output Terminal `Q3` defineLM (Load Meter)Output selection

LM (Load Meter) AdjustmentAM1 (Analog Meter1)Output selection

AM1 (Analog Meter1)Output AdjustmentAM2 (Analog Meter2)Output selection

AM2 (Analog Meter2)Output AdjustmentReturn Code

P5 defineP6 defineV2 mode

V2 filterV2 volt x1V2 freq y2

V2 volt x2V2 freq y2

F mode

F pulse set

F pulse numF filterF pulse x1F freq y1

F pulse x2F freq y2

PG P-gainPG I-gainPG Slip freqQ1 define

Q2 defineQ3 defineLM mode

LM adjustAM1 mode

AM1 adjustAM2 mode

AM2 adjustNot displayed

345

678

9I 0

I 4

I 5

I 6I 7I 8I 9

202 I

22232430

3 I3234

3540

4 I42

4399

--

10.010.01

0.010.01

-

-

11

0.010.01

0.010.01

111-

-

4 (XCEL-M)5 (XCEL-H)

0 (None)

10 [ms]0.00 [V]0.00 [Hz]

10.00 [V]60.00 [Hz]

0 (None)

0 (A+B)

102410 [ms]

0.00 [kHz]0.00 [Hz]

10.00 [kHz]60.00 [Hz]

3000300

100 [%]0 (FDT-1)

1 (FDT-2)2 (FDT-3)1 (Current)

100 [%]0 (Frequency)

100 [%]3 (DC link Vtg)

100 [%]1

YesYesNo

YesYesYes

YesYes

No

Yes

NoYesYesYes

YesYes

YesYesYesYes

YesYesYes

YesYes

YesYes

YesYes

Same as aboveSame as above

0 to 10000 [ms]0 to 10 [V]

0 to FU1-20 (Max.freq.)

0 to 10 [V]0 to FU1-20 (Max.freq.)

360 to 40960 to 9999 [ms]0 to 100 [kH]

0 to FU1-20 (Max.freq.)

0 to 100 [kHz]0 to FU1-20 (Max.freq.)

0 to 99990 to 99990 to 20[%]

Same as aboveSame as above

100 to 200 [%]

100 to 200 [%]

100 to 200[%]

Interlock1Interlock2Interlock3Interlock4

NoneOverride

Reference

NoneFee-backReference

A+BA

FDT-1FDT-2FDT-3FDT-4FDT-5

OLIOLStallOVLVOH

Lost CommandRunStop

SteadyINV line

COMM lineSearch

Step pulseSeq pulse

ReadyTrv. ACCTrv. DEC

MMC

FrequencyCurrentVoltage

DC link Vtg

FrequencyCurrentVoltage

DC link Vtg

FrequencyCurrentVoltage

DC link Vtg

Not available

29303132

012

01201

0123456789

1 011121314151617181920212223

0123

0123

0123

[PROG/ENT]or

[SHIFT/ESC]

EXT group appears only when the corresponding option boards are installed.

Page 18: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Program Parameter Descriptions

16

6. Communication Group [COM]Code Description UnitsLCD 7-segment

Keypad Display Setting Range Factory AdjustableLCD 7-segment Default during run

COM-00COM-01

COM-02

COM-03COM-04

COM-05COM-10COM-11

COM-12

COM-13

COM-17COM-20COM-30COM-31COM-32COM-33COM-34COM-35COM-36COM-37COM-38COM-40COM-41COM-42COM-43COM-44COM-45COM-46COM-47COM-48COM-52COM-99

Jump to desired code #Option board Type display

Option mode

Option versionDigital (Binary)option input mode selection

Digital (Binary)input filterDevice Net IDDevice Net baud rate

Device Net output impedence

Device Net input impedence

PLC station IDProfibus-DP IDNumber of outputOutput 1Output 2Output 3Output 4Output 5Output 6Output 7Output 8Number of inputInput 1 Input 2Input 3Input 4Input 5Input 6Input 7Input 8Modbus-RTU modeReturn Code

Jump codeOpt B/D

Opt Mode

Opt VersionD-in Mode

Digital FtrMAC IDBaud Rate

Out Instance

In Instance

Station IDProfi MAC IDOutput NumOutput 1Output 1Output 1Output 1Output 1Output 1Output 1Output 1Input NumInput 1Input 2Input 3Input 4Input 5Input 6Input 7Input 8ModBus Modenot displayed

Not DisplayedI

2

34

5I 0I I

I 2

I 3

I 720303I32333435363738404 I424344454647485299

11

1

1

111

1

1

111--------1----------

10 (None)

0 (None)

0 (8BitBin)

150

0 (125 bps)

0 (20)

0 (70)

113

000A (HEX)000A (HEX)000A (HEX)000A (HEX)000A (HEX)000A (HEX)000A (HEX)000A (HEX)

2000A (HEX)000A (HEX)000A (HEX)000A (HEX)000A (HEX)000A (HEX)000A (HEX)000A (HEX)

ModBus-RTU1

YesYes

No

NoYes

YesYesYes

Yes

Yes

YesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYes

Option version

0 to 500 to 63

0 to 630 to 127 0 to 8

0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)

0 to 80000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)0000 to 57FF (HEX)

Mofibus-RTU

0 to 99None

Device NetSynchroPLC-GF

Profibus-DPDigital-inRS485

Mofibus-RTUNone

CommandFrequencyCmd+Freq

8bit Bin8 BCD 1%8 BCD 1Hz12 Bit Bin

12 BCD 0.1%12 BCD 0.1Hz12 BCD 1Hz

125kbps250kbps500kbps

20211001017071110111

Not available

Not available012345670123

1234567

01201230123

[PROG/ENT]or

[SHIFT/ESC]

7. Application Group [APP]Code Description UnitsLCD 7-segment

Keypad Display Setting Range Factory AdjustableLCD 7-segment Default during run

APP-00APP-01

APP-02APP-03APP-04APP-05APP-06APP-07APP-08APP-09APP-10APP-11APP-12APP-13APP-14

Jump to desired code #Application mode

Traverse operation bandTraverse scramble bandTraverse acceleration timeTraverse deceleration timeTraverse offset HighTraverse offset LowNo. of Aux. Motor in runningStart aux. MotorOperation time display by auto-changeStarting frequency of Aux. Motor 1Starting frequency of Aux. Motor 2Starting frequency of Aux. Motor 3Starting frequency of Aux. Motor 4

Jump codeApp Mode

Trv. AmpTrv. ScrTrv Acc TimeTrv Dec TimeTrv Off HiTrv Off LoAux Mot RunStart AuxAuto Op TimeStart freq 1Start freq 2Start freq 3Start freq 4

Not DisplayedI

23456789I 0I II 2I 3I 4

11

0.10.10.10.10.10.1-1

0.010.010.010.010.01

10 (None)

0.0 [%]0.0 [%]

2.0 [sec]3.0 [sec]0.0 [%]0.0 [%]

#1#

49.99 [Hz]49.99 [Hz]49.99 [Hz]49.99 [Hz]

YesNo

YesYesYesYesYesYes

-Yes

-YesYesYesYes

0 to 99None

TraverseMMC

DRAW

Not available0123

0.0 to 20.0 [%]0.0 to 50.0 [%]

0.1 to 6000 [sec]0.1 to 6000 [sec]0.0 to 20.0 [%]0.0 to 20.0 [%]

#1 to 4

#0 to FU1-20 (Max.freq)0 to FU1-20 (Max.freq)0 to FU1-20 (Max.freq)0 to FU1-20 (Max.freq)

Page 19: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

17

7. Application Group [APP]Code Description UnitsLCD 7-segment

Keypad Display Setting Range Factory AdjustableLCD 7-segment Default during run

APP-17APP-18APP-19APP-20APP-21APP-22

APP-23APP-24APP-25APP-26APP-27APP-28APP-29

APP-30APP-31APP-32

APP-33

Starting frequency of Aux. Motor 3Starting frequency of Aux. Motor 4Aux.Motor starting delay timeAux.Motor stop delay timeNumber of Aux. MotorBypass selection

Sleep delaySleep frequencyWakeup levelAuto change mode selectionAuto change timeAuto change levelInterlock selection

Actual value displayActual value percentageDraw mode selection

Draw percentage selection

Stop freq 3Stop freq 4Aux start DTAux stop DTNbr Aux`sRegul Bypass

Sleep DelaySleep FreqWakeup levelAutoCh_ModeAutoCh_intvAutoCh_Mode levelInter-lock

Actal ValueActal PercDraw Mod

DrawPerc

I 7I 8I 9202 I22

23242526272829

303 I32

22

0.010.010.10.111

0.10.010.11

00 : 010.11

--1

0.1

15.00 [Hz]15.00 [Hz]60.00 [sec]60.00 [sec]

40 (None)

60.00 [sec]19.00 [Hz]35.0 [%]

172:00

20.0 [%]0 (None)

##

0( None)

00.0 [%]

YesYesYesYesYesYes

YesYesYesYesYesYesYes

--

Yes

Yes

0 to FU1-20 (Max.freq)0 to FU1-20 (Max.freq)

0.0 to 9999 [sec]0.0 to 9999 [sec]

0 to 4

0.0 to 9999 [sec]0 to FU1-20 (Max.freq)

0.0 to 100.0 [%]0 to 2

00:00 to 99:000.0 to 100.0 [%]

##

0.0 to 150.0 [%]

NoneYes

NoneYes

NoneV1_DrawI_Draw

V2_Draw

01

0

10123

Code Function Description LCD 7-segmentKeypad Display Sub-Board Type

Sub-A Board Sub-A Board Sub-C Board EXT-01EXT-02EXT-03EXT-04EXT-05EXT-06EXT-07EXT-08

EXT-09EXT-10

EXT-14EXT-15EXT-16EXT-17EXT-18EXT-19

EXT-20EXT-21

EXT-22EXT-23EXT-24EXT-30EXT-31EXT-32EXT-34EXT-35EXT-40EXT-41EXT-42EXT-43

Sub-board selectionMulti-function Input Terminal `P4`Multi-function Input Terminal `P5`Multi-function Input Terminal `P6`V2 Mode selectionFiltering Time Constant for V2 Input SignalV2 Input Minnmum VoltageFrequency corresponding to V2 Input Minnmum VoltageV2 Input Maximum VoltageFrequency corresponding to V2 Input Maximum VoltageUsage for Pulse Input SignalPulse Input Signal selectionEncoder Pulse selectionFiltering Time Constant for pulse Input SignalPulse Input Minimum FrequencyFrequency Output corresponding to PulseInput Minimum FrequencyPulse Input Maximum FrequencyFrequency Output corresponding to PulseInput Minimum FrequencyP-Gain for PG OptionI-Gain for PG OptionSlip Frequency for PG OptionMulti-function Output Terminal `Q1`Multi-function Output Terminal `Q2`Multi-function Output Terminal `Q3`LM (Load Meter) Output selectionLM (Load Meter) Output AdjustmentAM1 (Analog Meter1) Output selectionAM1 (Analog Meter1) Output AdjustmentAM2 (Analog Meter2) Output selectionAM2Analog Meter2) Output Adjustment

Sub B/DP4 defineP5 defineP6 defineV2 modeV2 filterV2 volt x1V2 freq y1

V2 volt x2V2 freq y2

F modeF pulse setF pulse numF filterF pulse x1f freq y1

F pulse x2f freq y2

PG P-gainPG I-gainPG Slip freqq1 defineq2 defineq3 defineLM modeLM adjustAM1 modeAM1 adjustAm2 modeAM2 adjust

I2345678

9I 0

I 4I 5I 6I 7I 8I 9

202 I

222324303 I323435404 I4243

●●●●●●●●

●●

●●●●●

●●●●●●

●●

●●●

●●●●●●●●

●●

●●●●

Note)Sub-Board Selection Guide according to its Function

[1] Code FU1-08 through FU1-11 appears only when FU1-07 is set at ‘DC-brake‘.[2] Code FU1-24 through FU1-25 appears only when FU1-23 is set at ‘Yes‘.[3] Code FU1-30 through FU1-37 appears only when FU1-29 is set at ‘User V/F‘.[4] Code FU1-51 through FU1-53 appears only when FU1-50 is set at ‘Yes‘.[5] Code FU2-11 through FU2-16 appears only when FU2-10is set at ‘Yes‘.[6] The rated motor is automatically set according to the inverter model name. If different motor is used, set the rated motor capacity connected.[7] This value is automatically entered according to the rated motor set in FU2-30. If different, set the correct value as the motor.[8] The setting range of carrier frequency is decided depending on drives’ capacity (over 30kW).[9] This value is automatically entered according to the rated motor set in FU2-30. If different, set the correct value as the motor.[10] Code FU2-47 through FU2-60 appears only when FU2-39 is set at ‘PID‘.[11] Code FU2-76 appears only when FU2-75 is set at ‘Ext.DB-R‘.[12] Code FU2-81 through FU2-90 appears only when one of I/O-12 ~ I/O-14 is set at ‘2nd function‘.[13] Code/O-46 through I/O-49are used in Option Board like RS485, Device Net and F-net etc.[14] The ‘Seq#‘ of code I/O-53 through I/O-60 varies according to the sequence number selected in I/O-51.

The parameter code may be extended to I/O-84 dependon the number of steps set in I/O-52 because the steps can be set up to 8.

Page 20: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Dimension

18

Dimension (mm)

MODE PROG

LC-200

ENT

FWDREV

SHIFTESC

STOPRESET

CAUTION

Read the manual and follow the safety instruction before installation or operationDo not the power supply to the drive output terminal (U, V, W)Before opening the cover, disconnect all power and wait at least 3 minutes untill DC bus capacitors discharge.`Risk of Electric Shock`-more than one disconnect switch is required to de -energize the equipment before servicing.

PROGENT

LC-200

RUN

SHIFTESC

STOPRESET

DRV FU1 FU2 I / O EXT

CAUTION

Read the manual and follow the safety instruction before installation or operationDo not the power supply to the drive output terminal (U, V, W)Before opening the cover, disconnect all power and wait at least 3 minutes untill DC bus capacitors discharge.`Risk of Electric Shock`-more than one disconnect switch is required to de -energize the equipment before servicing.

W1W2

6

H17.

5

D1

H2

MODE PROG

LC-200

ENT

FWDREV

SHIFTESC

STOPRESET

CAUTION

Read the manual and follow the safety instruction before installation or operationDo not the power supply to the drive output terminal (U, V, W)Before opening the cover, disconnect all power and wait at least 3 minutes untill DC bus capacitors discharge.`Risk of Electric Shock`-more than one disconnect switch is required to de -energize the equipment before servicing.

CAUTION

Read the manual and follow the safety instruction before installation or operationDo not the power supply to the drive output terminal (U, V, W)Before opening the cover, disconnect all power and wait at least 3 minutes untill DC bus capacitors discharge.`Risk of Electric Shock`-more than one disconnect switch is required to de -energize the equipment before servicing.

LC-200SHIFTESC

PROGENT RUNSTOP

RESET

DRV FU1 FU2 I / O EXT

H1

W1W2

6

D1

7.5

H2Inverter

SV008iS5-2/4SV015iS5-2/4SV022iS5-2/4SV037iS5-2/4SV055iS5-2/4SV075iS5-2/4

W1

150150150150200200

W2

130130130130180180

H1

284284284284355355

H2

269269269269340340

D2

156.5156.5156.5156.5182.5182.5

InverterSV110iS5-2/4SV150iS5-2/4SV185iS5-2/4SV220iS5-2/4

W1

250250304304

W2

230230284284

H1

385385460460

H2

370370445445

D2

201201234234

1. SV008iS5-2 SV015iS5-2 SV022iS5-2 SV037iS5-2 SV055iS5-2 SV075iS5-2 SV008iS5-4 SV015iS5-4 SV022iS5-4 SV037iS5-4 SV055iS5-4SV075iS5-4

Class Type W1 W2 W3 H1 H2 D1 D2

200-230V

380-480V

SV300iS5-2 375 360 275 615 593.5 277.5 230.5SV370iS5-2 375 360 275 615 593.5 277.5 230.5SV450iS5-2 375 360 275 780 758.5 300.7 230.5SV550iS5-2 375 360 275 780 758.5 300.7 230.5SV300iS5-4 350 319.2 270 680 662 311.2 256.6SV370iS5-4 350 319.2 270 680 662 311.2 256.6SV450iS5-4 375 359.6 275 780 760.5 329 259SV550iS5-4 375 359.6 275 780 760.5 329 259SV750iS5-4 375 359.6 275 780 760.5 329 259

(unit : mm)

(unit : mm)

(unit : mm)

2. SV110iS5-2 SV150iS5-2 SV185iS5-2 SV220iS5-2 SV110iS5-4 SV150iS5-4 SV185iS5-4 SV220iS5-4

3. SV300iS5-2 SV370iS5-2 SV450iS5-2 SV550iS5-2 SV300iS5-4 SV370iS5-4 SV450iS5-4 SV550iS5-4 SV750iS5-4

MODE PROG

LC-200

ENT

FWDREV

SHIFTESC

STOPRESET

CAUTION

Read the manual and follow the safety instruction before installation or operationDo not the power supply to the drive output terminal (U, V, W)Before opening the cover, disconnect all power and wait at least 3 minutes untill DC bus capacitors discharge.`Risk of Electric Shock`-more than one disconnect switch is required to de -energize the equipment before servicing.

CAUTION

Read the manual and follow the safety instruction before installation or operationDo not the power supply to the drive output terminal (U, V, W)Before opening the cover, disconnect all power and wait at least 3 minutes untill DC bus capacitors discharge.`Risk of Electric Shock`-more than one disconnect switch is required to de -energize the equipment before servicing.

LC-200SHIFTESC

PROGENT RUNSTOP

RESET

DRV FU1 FU2 I / O EXT

H1

W1W2

6

D1

7.5

H2

Page 21: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

19

Options

Internal Installation

External Installation

Option Name

Sub Board

Option Board

Keypad

Remote Cable

Dynamic Braking

Description

Sub-A Board (Extended I/O)

Sub-B Board (speed Feedback)

Sub-C Board (Extended I/O)

Device Net

PLC Communication (F-Net)

RS-485

Profi-Bus

ModBus-RTU

LCD

LED (7-segment)Remote CableDB ResistorDB Unit

Extended I/O module3 multi-function inputs (P4, P5, P6)3 multi-function outputs (Q1, Q2, Q3)Auxiliary analog frequency reference (V2)Lm (Load meter) Output (0 ~ 10V)Encoder pulse input-Speed feedback (AOC, BOC /A+, A-, B+ B-)Encoder pulse output (FBA, FBB)Extended I/O module3 multi-function inputs (P4, P5, P6)1 multi-function outputs (Q1)Isolated auxiliary analog frequency reference (V2)2 Isolated analog meter output (AM1.AM2)Embedded DeviceNet protrolCan ControllerInverter Connection : Max.64Input Voltage : DC 11 ~25VBaud Rate : 125, 250, 500k bpsCSMA/CD-NBA methodConnection with Fnet communication module of GLOFA PLCInverter Connection : Max.64Baud Rate : Max. 1M bpsToken methodRS-485 CommunicationInverter Connection : Max.32Baud Rate : Max. 19200 bpsConnection to ProfiBus networkDevice Type : Profibus Dp SlaveInverter Connection : Max. 64Baud Rate : Max. 12M bpsModBus-RTU CommunicationInverter Connection : Max. 32Baud Rate : Max.19200bps32 Character displayDownload and Upload from the keypad6 digit 7-segment display2n, 3m, 5m long keypad cables for separate keypad instaiiation.Enables inverter to decelerate rapidlyDB units are provided as an option for 15~75kW inverters

88.5

172

125150

12.512.5

3.5

Dynamic Braking Unit

WRINO

183

192

Dynamic braking (DB)unit

Max. DC Input VoltageApplication Motor [kW]DB Resistor Wattage [kW]*

Resistor Value [1]Average Braking TorqueEnable Duty (ED)Output SignalProtectionEnvironment Ambient Temp.HumidityAltitudeCooling MethodInstallation

Model Name SV150DBU-2DC400V

15 202.4 2.415 10

150%50%

SV220DBU-2DC400V

25 303.65

150%50%

SV370DBU-2DC400V

30 376.4 6.4

4.2100%

SV550DBU-4DC400V

45 559.6 9.6

2.8100%10%

SV150DBU-4DC800V

15 2022.44030150%10%

SV220DBU-4DC800V

25 303.620

150%10%

SV370DBU-4DC800V

30 376.416.9

150%10%

SV550DBU-4DC800V

45 559.611.4

100%10%

SV750DBU-4DC800V

7512.88.4

100%10%

Heat sink over-heat signal outputHeat sink over-heat output cut-off

-10˚C ~ 40˚CBelow 90% Relative Humidity (Non Condensing)

Less than 3,300ft (1,000m) without deratingSelf-cooling

Avoid corrosive gas, oil mist, flammable gas and dust

*This resister wattage is based on 150% braking torque and 5% ED. Double the wattage in case of using with 10% ED application.

Page 22: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

20

1. Internal (built-in) resistorsThe DB resistors are built-in for 0.75 ~ 3.7kW models.

*Above table is based on 100% braking torque

Dynamic braking (DB)unit

Peripheral Devices

SV008iS5-2SV015iS5-2SV022iS5-2SV037iS5-2SV008iS5-2SV015iS5-2SV022iS5-2SV037iS5-2

Model Name kW0.75 1.52.23.7

0.751.52.23.7

Internal DB Resistor200 1, 100Watt100 1, 100Watt60 1, 100Watt40 1, 100Watt

900 1, 100Watt450 1, 100Watt300 1, 100Watt200 1, 100Watt

ED / Continuous Braking time3% / 5seconds3% / 5seconds2% / 5seconds2% / 5seconds3% / 5seconds3% / 5seconds2% / 5seconds2% / 5seconds

2.External (optional) resistors

*Above table is based on 100% braking torque

SV008iS5-2SV015iS5-2SV022iS5-2SV037iS5-2SV055iS5-2SV075iS5-2SV110iS5-2SV150iS5-2SV185iS5-2SV220iS5-2SV300iS5-2SV370iS5-2SV450iS5-2SV550iS5-2SV008iS5-4SV015iS5-4SV022iS5-4SV037iS5-4SV055iS5-4SV075iS5-4SV110iS5-4SV150iS5-4SV185iS5-4SV220iS5-4SV300iS5-4SV370iS5-4SV450iS5-4SV550iS5-4SV750iS5-4

Model Name kW

0.751.52.23.75.57.51115

18.52230374555

0.751.52.23.75.57.51115

18.5223037455575

DB Resistor (100% Braking Torque)

200 1, 100Watt100 1, 200Watt60 1, 300Watt40 1, 500Watt3 1, 700Watt

20 1, 1000Watt15 1, 1400Watt11 1, 2000Watt9 1, 2400Watt8 1, 2800Watt

4.2 1, 6400Watt4.2 1, 6400Watt2.8 1, 9600Watt2.8 1, 9600Watt900 1, 100Watt450 1, 200Watt300 1, 300Watt200 1, 500Watt120 1, 700Watt90 1, 1000Watt60 1, 1400Watt45 1, 2000Watt35 1, 2400Watt30 1, 2800Watt

16.9 1, 6400Watt16.9 1, 6400Watt11.4 1, 9600Watt11.4 1, 9600Watt8.4 1, 12800Watt

DB Resistor (150% Braking Torque)

150 1, 150Watt60 1, 300Watt50 1, 400Watt33 1, 600Watt20 1, 800Watt

15 1, 1200Watt10 1, 2400Watt8 1, 2400Watt51, 3600Watt51, 3600Watt

----

600 1, 150Watt300 1, 300Watt200 1, 400Watt130 1, 600Watt85 1, 1000Watt60 1, 1200Watt40 1, 2000Watt30 1, 2400Watt20 1, 3600Watt20 1, 3600Watt

-----

Inverter Models HP MCCB, ELB Magnetic Contactor DC ReactorAC Input Fuse AC ReactorWire, mm2 (AWG)

SV008iS5-2SV015iS5-2SV022iS5-2SV037iS5-2SV055iS5-2SV075iS5-2SV110iS5-2SV150iS5-2SV185iS5-2SV220iS5-2SV300iS5-2SV370iS5-2SV450iS5-2SV550iS5-2SV008iS5-4SV015iS5-4SV022iS5-4SV037iS5-4SV055iS5-4SV075iS5-4

1235

7.51015202530405060751235

7.510

ABS33a, EBS33ABS33a, EBS33ABS33a, EBS33ABS33a, EBS33ABS53a, EBS53ABS63a, EBS63

ABS103a, EBS103ABS103a, EBS103ABS203a, EBS203ABS203a, EBS203ABS203a, EBS225ABS203a, EBS225ABS403a, EBS300ABS403a, EBS350

ABS33a, EBS33ABS33a, EBS33ABS33a, EBS33ABS33a, EBS33ABS33a, EBS33ABS33a, EBS33

SMC-10PSMC-10PSMC-15PSMC-20PSMC-25PSMC-35PSMC-50PSMC-65PSMC-80P

SMC-100PGMC-150GMC-180GMC-220GMC-300SMC-10PSMC-10PSMC-20PSMC-20PSMC-20PSMC-20P

2 (14)2 (14)2 (14)

3.5 (12)5.5 (10)

8 (8)14 (6)22 (4)30 (3)30 (3)

6060

100100

2 (14)2 (14)2 (14)2 (14)2 (14)

3.5 (12)

3.5 (12)3.5 (12)3.5 (12)3.5 (12)5.5 (10)5.5 (10)

14 (6)14 (6)22 (4)22 (4)

22223838

2 (14)2 (14)2 (14)2 (14)

3.5 (12)3.5 (12)

7.00mH, 5.7A4.05mH, 9.2A2.92mH, 13A1.98mH, 19A1.37mH, 29A1.05mH, 38A0.74mH, 56A0.57mH, 71A0.49mH, 91A

0.42mH, 107A0.35mH, 152.0A0.3mH, 180.0A

0.28mH, 221.0A0.25mH, 270.0A28.62mH, 2.7A16.14mH, 4.6A11.66mH, 7.1A

7.83mH, 10A5.34mH, 14A4.04mH, 19A

R,S,T U,V,W Ground

2 (14)2 (14)2 (14)

3.5 (12)5.5 (10)

8 (8)14 (6)22 (4)30 (3)38 (2)

6060

100100

2 (14)2 (14)2 (14)

3.5 (12)3.5 (12)5.5 (10)

10A15A25A40A40A50A70A

100A100A125A150A200A250A300A

6A10A10A20A20A30A

2.13mH, 5.7A1.20mH, 10A0.88mH, 14A0.56mH, 20A0.39mH, 30A0.28mH, 40A0.20mH, 59A0.15mH, 75A0.12mH, 96A

0.10mH, 112A0.08mH, 134.2A0.07mH, 160.6A0.06mH, 198.0A0.05mH, 242.0A

8.63mH, 2.8A4.81mH, 4.8A3.23mH, 7.5A2.34mH, 10A1.22mH, 15A1.14mH, 20A

Options, DB Resistor& Peripheral Devices

Page 23: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

Starvert iS5

21

RFI FilterIS5 Series Footprinting Filter

Inverter

THREE PHASE NOM. MAX.

Power Code Current TensionVoltage

LeakageCurrent

DimensionsL W H

MountingY X Weight Mount Output

Chokes

SV008iS5-2SV015iS5-2SV022iS5-2SV037iS5-2SV055iS5-2SV075iS5-2SV110iS5-2SV150iS5-2SV185iS5-2SV220iS5-2SV008iS5-4SV015iS5-4SV022iS5-4SV037iS5-4SV055iS5-4SV075iS5-4SV110iS5-4SV150iS5-4SV185iS5-4SV220iS5-4

FFS5-T012-(X)

FFS5-T020-(X)

FFS5-T030-(X)FFS5-T050-(X)

FFS5-T006-(X)

FFS5-T012-(X)

FFS5-T030-(X)

FFS5-T051-(X)

FFS5-T060-(X)FFS5-T070-(X)

0.75kW1.5kW2.2kW3.7kW5.5kW7.5kW11kW15kW18kW22kW

0.75kW1.5kW2.2kW3.7kW5.5kW7.5kW11kW15kW18kW22kW

12A

20A

30A50A

100A

120A

6A

12A

30A

51A

60A70A

250VA

250VA

250VA250VA

250VA

250VA

380VA

380VA

380VA

380VA

380VA380VA

0.3A 18A

0.3A 18A

0.3A 18A0.3A 18A0.3A 18A

0.3A 18A

0.5A 27A

0.5A 27A

0.5A 27A

0.5A 27A

0.5A 27A0.5A 27A

329 X 149.5 X 50

329 X 149.5 X 50

415 X 199.5 X 60415 X 199.5 X 60

329 X 149.5 X 50

329 X 149.5 X 50

415 X 199.5 X 60

466 X 258 X 65

541 X 332 X 65541 X 332 X 65

315 X 120

315 X 120

410 X160410 X 160

315 X 120

315 X 120

401 X 160

515.5 X 255

515.5 X 255

M5

M5

M5M5

M5

M5

M5

M8

M8M8

FS-2

FS-2

FS-2FS-2FS-3

FS-3

FS-1

FS-2

FS-2

FS-2

FS-2FS-2

IS5 Series Standard Filter

Inverter

THREE PHASE NOM. MAX.

Power Code Current TensionVoltage

LeakageCurrent

DimensionsL W H

MountingY X Weight Mount Output

Chokes

SV008iS5-2SV015iS5-2SV022iS5-2SV037iS5-2SV055iS5-2SV075iS5-2SV110iS5-2SV150iS5-2SV185iS5-2SV220iS5-2SV300iS5-2SV370iS5-2SV450iS5-2SV550iS5-2SV008iS5-4SV015iS5-4SV022iS5-4SV037iS5-4SV055iS5-4SV075iS5-4SV110iS5-4SV150iS5-4SV185iS5-4SV220iS5-4SV300iS5-4SV370iS5-4SV450iS5-4SV550iS5-4SV750iS5-4

FE-T012-(X)

FE-T020-(X)

FE-T030-(X)FE-T050-(X)

FE-T100-(x)

FE-T120-(x)

FE-T150-2FE-T170-2FE-T230-2FE-T260-2

FE-T006-(X)

FE-T012-(X)

FE-T030-(X)

FE-T050-(X)

FE-T060-(X)FE-T070-(X)FE-T070-2FE-T100-2FE-T120-2FE-T120-2FE-T170-2

--

--

------

--

--

--

--

--

----

(X) (1) Industrial environment EN 50081-1 (A class)(2) Domestic and industrial environment EN 50081-1 (B class)

Peripheral DevicesInverter Models kW MCCB, ELB Magnetic Contactor DC ReactorAC Input Fuse AC ReactorWire, mm2 (AWG)

SV110iS5-4SV150iS5-4SV185iS5-4SV220iS5-4SV300iS5-4SV370iS5-4SV450iS5-4SV550iS5-4SV750iS5-4

1520253040506075

100

ABS53a, EBS53ABS63a, EBS63

ABS103a, EBS103ABS103a, EBS103ABS203a, EBS125ABS203a, EBS150ABS203a, EBS175ABS203a, EBS225ABS203a, EBS225

SMC-20PSMC-25PSMC-35PSMC-50PGMC-85

GMC-100GMC-125GMC-150GMC-180

5.5 (10)8 (8)8 (8)

14 (6)2222383860

8 (8)8 (8)

14 (6)14 (6)

1414222222

2.76mH, 29A2.18mH, 36A1.79mH, 48A1.54mH, 55A

1.19mH, 76.0A0.98mH, 93.0A

0.89mH, 112.0A0.75mH, 135.0A0.44mH, 187.0A

R,S,T U,V,W Ground

8 (8)14 (6)14 (6)22 (4)

2222383860

35A45A60A70A

100A100A100A150A200A

0.81mH, 30A0.61mH, 38A0.45mH, 50A0.39mH, 58A

0.33mH, 67.1A0.27mH, 82.5A

0.22mH,100.1A0.18mH, 121.0A0.13mH, 167.2A

0.75kW1.5kW2.2kW3.7kW5.5kW7.5kW11kW15kW18kW22kW30kW37kW45kW55kW

0.75kW1.5kW2.2kW3.7kW5.5kW7.5kW11kW15kW18kW22kW30kW37kW45kW55kW75kW

12A

20A

30A50A

100A

120A

150A170A230A280A

6A

12A

30A

50A

60A70A70A

100A120A120A170A

250VA

250VA

250VA250VA250VA

250VAC

250VAC250VAC250VAC250VAC

380VAC

380VAC

380VAC

380VAC

380VAC380VAC380VAC38VAC38VAC38VAC38VAC

0.3A 18A

0.3A 18A

0.3A 18A0.3A 18A0.3A 18A

1.3A 180A

1.3A 150A1.3A 150A1.3A 150A1.3A 150A

0.5A 27A

0.5A 27A

0.5A 27A

0.5A 27A

0.5A 27A0.5A 27A1.3A 150A1.3A 150A1.3A 150A1.3A 150A1.3A 150A

250 X 110 X 60

270 X 140 X 60

270 X 140 X 60270 X 140 X 60420 X 200 X 130

420 X 200 X 130

480 X 200 X 160480 X 200 X 160580 X 250 X 205580 X 250 X 205

250 X 110 X 60

250 X 110 X 60

270 X 140 X 60

270 X 140 X 90

270 X 140 X 90350 X 180 X 90350 X 180 X 90425 X 200 X 130425 X 200 X 130425 X 200 X 130480 X 200 X 160

238 X 76

258 X 106

258 X 106258 X 106408 X 166

408 X 106

468 X 166468 X 166560 X 170560 X 170

238 X 76

238 X 76

258 X 106

258 X 106

258 X 106338 X 146338 X 146408 X 166408 X 166408 X 166468 X 166

FS-2

FS-2

FS-2FS-2FS-3

FS-3

FS-3FS-3FS-4FS-4

FS-2

FS-2

FS-2

FS-2

FS-2FS-2FS-3FS-3FS-3FS-3FS-3

Page 24: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

22

FF Series (Footprint)

FS Series (output chokes)

FE Series (Standard)

Dimensions

FF Series (Footprint)

FE Series (Standard)

RFI Filter

TypeFS-1FS-2FS-3FS-4

D21

28.54858

W85105150200

H4662110170

X7090

125 x 30180 x 45

O5555

HH

W X

Y

L

WX

Y

HD

W X

Y

L

RED

CARG

A

MOTOR

INVERTER

FILTER

SHIELDED CABLE

INVERTERFILTER

SHIELDED CABLEMOTOR

RFI Filters

Page 25: STARVERT iS5 LS INVERTER/4- iS5_E.pdf · 2014. 5. 14. · Features & Selection Guide Specifications & Wiring Terminal Configuration, ... Options, DB Resistor & Peripheral Devices

www.lsis.biz2003.2 LSIS Co.,Ltd. All rights reserved.

Specifications in this catalog are subject to change without notice due to continuous product development and improvement.

HEAD OFFICELS Tower 1026-6, Hogye-dong, Dongan-gu, Anyang-si,Gyeonggi-do 431-848, Korea

Middle East +82-2-2034-4901 / [email protected]

Europe & Africa +82-2-2034-4376 / [email protected]

Asia Pacific +82-2-2034-4645 / [email protected]

2011. 05 STARVERT iS5 (E) 2003. 2/(14) 2011. 05 Printed in Korea STAFF

LSIS (Middle East) FZE Dubai, U.A.E. Address: LOB 19 JAFZA VIEW TOWER Room 205, Jebel Ali Freezone P.O. Box 114216, Dubai, United Arab EmiratesTel: 971-4-886 5360 Fax: 971-4-886-5361 e-mail: [email protected]

Dalian LSIS Co., Ltd. Dalian, ChinaAddress: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, ChinaTel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: [email protected]

LSIS (Wuxi) Co., Ltd. Wuxi, ChinaAddress: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.ChinaTel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: [email protected]

LSIS-VINA Co., Ltd. Hanoi, VietnamAddress: Nguyen Khe - Dong Anh - Ha Noi - Viet NamTel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: [email protected]

LSIS-VINA Co., Ltd. Hochiminh , VietnamAddress: 41 Nguyen Thi Minh Khai Str. Yoco Bldg 4th Floor, Hochiminh City, VietnamTel: 84-8-3822-7941 Fax: 84-8-3822-7942 e-mail: [email protected]

LSIS Tokyo Office Tokyo, JapanAddress : 16th, Higashi-Kan, Akasaka Twin Tower, 2-17-22, Akasaka, Minato-ku, Tokyo, JapanTel: 81-3-3582-9128 Fax: 81-3-3582-2667 e-mail: [email protected]

LSIS Shanghai Office Shanghai, ChinaAddress: Room E-G, 12th Floor Huamin Empire Plaza, No.726, West Yan'an Road Shanghai 200050, P.R. ChinaTel: 86-21-5237-9977 (609) Fax: 89-21-5237-7191 e-mail: [email protected]

LSIS Beijing Office Beijing, ChinaAddress: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District,Beijing 100013, P.R. ChinaTel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: [email protected]

LSIS Guangzhou Office Guangzhou, ChinaAddress: Room 1403,14F,New Poly Tower,2 Zhongshan Liu Road,Guangzhou, P.R. ChinaTel: 86-20-8326-6764 Fax: 86-20-8326-6287 e-mail: [email protected]

LSIS Chengdu Office Chengdu, ChinaAddress: Room 1701 17Floor, huanminhanjun internationnal Building, No1 Fuxing Road Chengdu, 610041, P.R. ChinaTel: 86-28-8670-3101 Fax: 86-28-8670-3203 e-mail: [email protected]

LSIS Qingdao Office Qingdao, ChinaAddress: 7B40,Haixin Guangchang Shenye Building B, No.9, Shandong Road Qingdao 26600, P.R. ChinaTel: 86-532-8501-6568 Fax: 86-532-583-3793 e-mail: [email protected]

Global Network

For your safety, please read user's manual thoroughly before operating.

Contact the nearest authorized service facility for examination, repair, or adjustment.

Please contact a qualified service technician when you need maintenance.Do not disassemble or repair by yourself!

Any maintenance and inspection shall be performed by the personnel having expertise concerned.Safety Instructions