STANDARD PUMP SOFT STARTER (SPS-RV) Wide-range, Class 10 electronic overload Current phase unbalance protection Locked rotor / stall protection Cycle fault protection Accepts 200-600 VAC directly, true plug and play Voltage auto-run input Dry contact auto-run input Status relay output Hand/Off/Auto keypad with LEDs for mode, fault, and run indication Across-the-line start for emergency situations Adjustable current limit, start/stop voltage, and start/stop time SCR over-temperature detection Shorted SCR detection UL 489 circuit breaker provides branch and short circuit protection * Service entrance rated No fuses required – saves time and money Lockable handle for safety Integrated electronic pump protection overload and a wide range of voltage acceptance (200~600 VAC). 3Ø, 50/60 Hz, 200~600 VAC, 6-85 A Door mounted HOA keypad Housed in an outdoor rated, gasketed, NEMA 3R enclosure NEMA rated bypass contactor features 2.5 million electrical cycles at full rated current ELECTRONIC PROTECTION & AUTOMATION I/O SOFT STARTER FEATURES INDUSTRIAL GRADE CONSTRUCTION
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
STANDARD PUMP SOFT STARTER (SPS-RV)
� Wide-range, Class 10 electronic overload
� Current phase unbalance protection
� Locked rotor / stall protection
� Cycle fault protection
� Accepts 200-600 VAC directly, true plug and play
� Voltage auto-run input
� Dry contact auto-run input
� Status relay output
� Hand/Off/Auto keypad with LEDs for mode, fault, and run indication
� Across-the-line start for emergency situations
� Adjustable current limit, start/stop voltage, and start/stop time
� SCR over-temperature detection
� Shorted SCR detection
� UL 489 circuit breaker provides branch and short circuit protection* Service entrance rated
� No fuses required – saves time and money
� Lockable handle for safety
Integrated electronic pump protection overload and a wide range of voltage acceptance (200~600 VAC). 3Ø, 50/60 Hz, 200~600 VAC, 6-85 A
� Door mounted HOA keypad
� Housed in an outdoor rated, gasketed, NEMA 3R enclosure
� NEMA rated bypass contactor features 2.5 million electrical cycles at full rated current
ELECTRONIC PROTECTION & AUTOMATION I/O
SOFT STARTER FEATURES
INDUSTRIAL GRADE CONSTRUCTION
STANDARD PUMP SOFT STARTER (SPS-RV) - ORDERING AND SIZING INFORMATIONSTANDARD PUMP SOFT STARTER (WITH DISCONNECT)
*HP rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 full-load current, 3-phase alternating current motors.
3 Phase, 50/60Hz, 200~600VAC, NEMA Type 3R Enclosed Starter (Includes Service Entrance Circuit Breaker Disconnect)
Product Sizing: Submersible Motors - Reference Service Factor Amps on the motor nameplate or Franklin AIM manual Surface Motors - Reference Full Load Amps on the motor nameplate