Top Banner
STANDARD FOR RIPRAP AND CONDUIT OUTLET PROTECTION
11

Standard for riprap and conduit outlet protection

Feb 24, 2016

Download

Documents

urit

Standard for riprap and conduit outlet protection. Lets look at an example: Q 25 = 20.00 cfs, W O = 24 Inch or 2.00 ft. T W = 0.2 x D O =0.2 x 2.0 ft.= 0.40 ft., q =20.00 cfs / 2.00 ft. = 10.00 sfs - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Standard for  riprap and conduit  outlet protection

STANDARD FOR RIPRAP AND CONDUIT OUTLET PROTECTION

Page 2: Standard for  riprap and conduit  outlet protection

HOW MUCH OF A DIFFERENCE DOES THIS CHANGE MAKE ?

Lets look at an example:Q25 = 20.00 cfs, WO = 24 Inch or 2.00 ft.TW = 0.2 x DO =0.2 x 2.0 ft.= 0.40 ft., q =20.00 cfs / 2.00 ft. =

10.00 sfs

Old Equation: D50 = 0.016 x q1.33 =0.016 x 10.001.33 = 0.855 ft.

TW 0.40 ft.New Equation: D50 = 0.020 x q1.33 =0.020 x 10.001.33 = 1.069 ft.

TW 0.40 ft.

1.069 ft. = 1.25 = 25% Increase in D50

0.855 ft.

Page 3: Standard for  riprap and conduit  outlet protection

PREFORMED SCOUR HOLE SECTION HAS BEEN REARRANGED TO “FLOW” MORE LOGICALLY

Page 4: Standard for  riprap and conduit  outlet protection

HORIZONTAL APRON SECTION HAS BEEN REARRANGED TO “FLOW” MORE LOGICALLY

DO0.5

Page 5: Standard for  riprap and conduit  outlet protection

ISHBASH CURVE – CHANNEL RIPRAP

Page 6: Standard for  riprap and conduit  outlet protection

ISHBASH EQUATION

Vc is not the velocity correlated with Minimum Specific Energy !

Page 7: Standard for  riprap and conduit  outlet protection

FIGURE TS14C–6 GRAPHICAL SOLUTION FOR ISBASH TECHNIQUE FOR DIFFERENT STONE

DENSITY

Page 8: Standard for  riprap and conduit  outlet protection

DIFFERENT STONE DENSITY

Page 9: Standard for  riprap and conduit  outlet protection

AVAILABLE FOR VERY HIGH VELOCITY CIRCUMSTANCES

Page 10: Standard for  riprap and conduit  outlet protection

LANE METHOD – CHANNEL RIPRAP

Page 11: Standard for  riprap and conduit  outlet protection

RIPRAP QUESTIONS ?