STANDARD DESCRIPTION DRAWING
LT 900-03LT 900-02LT 900-01 TRENCHES Streets C-ES-140-01LT 800-02LT 800-01 UNDERGROUNDING OF PRIVATE PROPERTIES Plan and Schedule C-ES-150-01
SINGLE LIGHTING COLUMN Direct Supply from ETSA PitMULTIPLE LIGHTING COLUMNS
SURFACE PREPARATION SHALL BE IN ACCORDANCEPROTECTIVE COATINGS, PREVIOUSLY TAUBMANS).WITH 'INTERPLUS 356' (FROM INTERNATIONAL& BOTTOM) SHALL BE PAINTED TO 100mm A.F.G.L.THE RAG BOLTS AND COLUMN/BASE PLATE (TOPANTI-CORROSION COATING
600 MICRON SIEVE.
SAND SPECIFICATIONTHE SAND TO BE SUPPLIED AND INSTALLED IN
AND BE NON-PLASTIC WITH 100% PASSING A ACCORDANCE WITH THE INSTRUCTIONS BELOW,
TO TOP OF BOLTS
REFER TO STANDARD LT421-01 (Dwg C-ES-105-01)
TYPICAL 'IN-GROUND' COLUMN
WRAP COLUMN WITH PETROLATUM TAPE.
SAND TYPE.PROGRESSIVELY WATER IN THE SPECIFIEDPOSITION COLUMN CENTRALLY, PLUMB ANDCONDUIT(S) PROGRESSIVELY INTO COLUMN.LOWER COLUMN INTO SLEEVE AND FEED
TYPE AROUND SLEEVE.PROGRESSIVELY WATER IN SPECIFIED SAND
INSTALL FLEXIBLE CORRUGATED CONDUIT(S)3.
CABLE ENTRY IN APPROPRIATE LOCATION.2.
CLEARANCE BETWEEN SLEEVE & COLUMN.1.INSTALLATION PROCEDURE
CORPORATION OF THE CITY OF ADELAIDEMANUFACTURER'S NAMECONTRACT NUMBERMONTH/YEAR OF MANUFACTURE
4. POLE IDENTIFICATION LABEL REQUIREMENTS
25 50
GROUNDLEVEL
ENLARGEMENT AT FINISHED GROUND LEVEL
SUPPORT BLOCKMASONRY BASE
ACCESS OPENINGIN COLUMN
OCTAGONAL COLUMN
1250
(T
YP
ICA
L)
660
3000
PLA
NT
ING
DE
PT
H
POLE CAP
400 Ø
CEREMONIAL LIGHT
GALVANIZED STEEL
PAINTED AS SPECIFIED
600
CUT OUT FOR CABLE ENTRY
LUMINAIRE
CLEAT FOR FLEXIBLE POWER CABLE (IF REQUIRED). FOR DRAWING DETAILS SEE STANDARD LT110-02 (Dwg C-ES-122-02)
PROCESSED SOCKET OUTLET (IF REQUIRED). FOR DETAILS SEE STANDARD LT110-02 (Dwg C-ES-122-02)P.E. CELL. FOR DETAILS SEE STANDARD LT110-02 (Dwg C-ES-122-02)
CAST ALUMINIUM OCTAGONAL BASE TO FIT AROUND COLUMN. FOR DETAILS SEE STANDARD LT110-03 (Dwg C-ES-122-03)
REFER TO "ENLARGEMENT AT GROUND LEVEL (FOOTPATH)FOOTING DETAILS SEE STANDARD LT020-01 (Dwg C-ES-101-01)
NOTIFIED BY MANUFACTURER*NOTE DIMENSION TO BE
SE
E N
OT
E *
LIMIT STATE OF 38M/SBASIC WIND SPEED FOR SERVICEABLILTYWITH AS1170.2 WITH A MINIMUMDESIGN POLE IN ACCORDANCE
C-ES-122-01
05/2001
TL
JR/JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
01LT 110
CONSTRUCTION STANDARDLighting and Electrical
3.5M POST TOPCeremonial Column
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
TL
RS
85
8
360
170
100
85
20
CLEAT AND RECESS DETAILS
R55 studs
P.E. CELL (WHERE SPECIFIED)
5010
0
CLEAT TO REAR OF COLUMN FABRICATED FROM 10Ø ROD
FULLY WELDED RECESS TO REAR OF COLUMN WITH CUT-OUT TO ACCEPT "NILSEN RC315M" SWITCHED POWER OUTLET. SUPPLIED WITH GASKETED BLANKING PLATE
50Ø HOLE IN TOP PLATE
ENLARGEMENT AT ACCESS OPENING
30
250
X X
LABEL BEHIND COVER FIXED TO REAR OF ACCESS DOOR. FOR DETAILS SEE STANDARD LT110-01 (Dwg C-ES-122-01) 5
TAP M10 HOLES
25x6 STRAP FOR GEAR TRAY
M6 TAPPED HOLE TO SUIT DOOR SCREW
M10 x45 LONG HEX BOLT THROUGH LOWER STRAP, WELDED IN PLACE (THREAD TO BE RE-CUT AFTER GALVANIZING). COMPLETE WITH 2 GALVANIZED NUTS.
7mm HOLE TO SUIT M6 S/S ALLEN KEY SOCKET HD CAP SCREW. PROVIDE NYLON WASHER SAME SIZE AS SCREW HEAD
CLEAR OPENING 350x120 NOMINAL (COVER REMOVED)
ACCESS COVER DETAIL
1250
(T
YP
ICA
L)
660
3660
690
350
216
231.5
260.5 max
146 max
90
30
GROUND LEVEL
"ENLARGEMENT ATACCESS OPENING"
REFER TO
THREADED STUDS4 off M10x30 LONG
CLEAT TO REAR OFCOLUMN FABRICATEDFROM 10 Ø ROD
50x6 THICK ANTI-SINK STRAP
LIGHT COLUMN
120
600
P.E.CELL (WHERE SPECIFIED)
PETROLATUM TAPE (50mm ABOVE GROUND TO 150mm BELOW GROUND)
(WHERE SPECIFIED)
50Wx150H CUT-OUT TO REAR OF COLUMN FOR CABLE ENTRY
RECESS FOR POWER OUTLET
SE
E N
OT
E *
*NOTE DIMENSION TO BE NOTIFIED BY MANUFACTURER
LIMIT STATE OF 38M/SBASIC WIND SPEED FOR SERVICEABLILTYWITH AS1170.2 WITH A MINIMUMDESIGN POLE IN ACCORDANCE
C-ES-122-02
05/2001
TL
JR/JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
02LT 110
CONSTRUCTION STANDARDLighting and Electrical
3.5M POST TOPCeremonial Details
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
TL
RS
104
INTERNAL ELEVATION
510
R1690
635
620
595
565
FRONT ELEVATION
550425175
110
80
R30
300
R15
HALF BOTTOM VIEW(sides separated)
INTERNAL ELEVATION
120
45°
240
25
(separated)SIDE ELEVATION
25
25
45°220
HALF TOP VIEW
110
22040
HOLES FORCOUNTERSUNKM8 THREADED
HOLES FORJOINING FIXINGS
12.5 12.5 17.5
7.5
7.5
42.5
JOINING FIXINGS
JOININGEXTENSION
EXTENSIONJOINING
JOININGEXTENSION
5mm THICK JOININGEXTENSION WITH25mm PROJECTION
REFER TO STANDARD LT110-02 (Dwg. C-ES-122-02) FOR COLUMN DETAILS
C-ES-122-03
05/2001
TL
JR/JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
03LT 110
CONSTRUCTION STANDARDLighting and Electrical
3.5M POST TOPCeremonial Base
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
COLUMN TO CONFORM TO RELEVANT AUSTRALIAN STANDARDS AND ATTACHED ACC SPECIFICATION
COLUMN SHOULD BE HOT DIPPED GALVANIZED
2.
3.
(THREAD TO BE RE-CUT AFTER GALVANIZING)
5. LABEL REQUIREMENTS
CORPORATION OF THE CITY OF ADELAIDEMANUFACTURER'S NAMECONTRACT NUMBERMONTH/YEAR OF MANUFACTURE
CLEAR OPENING350x120 NOMINAL(COVER REMOVED)
C-ES-121-01
04/2001
TL
JR/JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
01LT 120
CONSTRUCTION STANDARDLighting and Electrical
3.5M POST TOPStreets/Park Lands
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
TL
RS
ACCESS COVER DETAIL
SECTION X-X
TAP M10 HOLES
25x6 STRAP
ENLARGEMENT ATACCESS OPENING
X
250
X
5
7mm HOLE TO SUIT M6 S/S ALLEN KEY SOCKET HD CAP SCREW PROVIDE NYLON WASHER, DIAMETER SAME SIZE AS SCREW HEAD
LABEL BEHIND COVER FIXED TO REAR OF ACCESS DOOR
M10x45 LONG HEX BOLT THROUGH LOWER STRAP. WELD HEAD AT BACK OF STRAP. (THREAD TO BE RE-CUTAFTER GALVANIZING) COMPLETE WITH 2 GALVANIZED NUTS.
M6 TAPPED HOLE TO SUIT DOOR SCREW
CLEAR OPENING 350x120 NOMINAL (COVER REMOVED)
TRANSITIONVIC POLE (CTFL)F10 - 152 - 92
2. PAINT FINISH DULUX BLACK REFER PAINT SPECIFICATION FOR APPLICATION CORPORATION OF THE CITY OF
ADELAIDEMANUFACTURER'S NAMECONTRACT NUMBERMONTH/YEAR OF MANUFACTURE
3. LABEL REQUIREMENTS
165
STANDARD LT020-01 (Dwg C-ES-101-01)
NOTE: 1. FOR FOOTING DETAILS REFER TO
GROUND TO 150mm BELOW GROUND)PETROLATUM TAPE (50mm ABOVE
AT ACCESS OPENING"
(FOOTPATH)
80 NB LIGHT PIPE
SPIGOT REQUIREMENTS76mm OD DIA. x 70mm HIGH
ACCESS OPENING
12 SIDED 165 A.F.
FINISHED GROUND LEVEL
REFER TO "ENLARGEMENT
FOOTING DETAILS SEE
50Wx150H CUTOUT
MASONRY BASE SUPPORT BLOCK
ANTI-SINK STRAP50x6 THICK
WITH ROUNDED CORNERS
300 Ø
150
600
POST TOP PARK LANDS HERITAGE
PLA
NT
ING
DE
PT
H10
0 m
in.
1250
(T
YP
ICA
L)
BASE 3mm G250 PLATE
3500
to b
otto
m o
f spi
got
600
1200
"UNIQUE SOLUTIONS"
VIC POLE BOULEVARD VPB3.5PG
RSL - 350 RESIDENTIAL POSTOP
STANDARD LT 020-01(Dwg C-ES-101-01)
OR EQUIVALENT APPROVEDS
EE
NO
TE
*
*NOTE DIMENSION TO BE NOTIFIED BY MANUFACTURER
DESIGN POLE IN ACCORDANCEWITH AS1170.2 WITH A MINIMUMBASIC WIND SPEED FOR SERVICEABLILTYLIMIT STATE OF 38M/S
C-ES-123-01
04-2001
TL
JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
01LT 130
CONSTRUCTION STANDARDLighting and Electrical
3.5M POST TOPHeritage
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
TL
RS
REFER TO STANDARD LT221-02 (Dwg C-ES-160-02) FOR SUPPLYCABLE PROTECTIONCOVER DETAILS
3500 ABOVE GROUND LEVEL TYPICAL OR 5000 WHERE 250mm CLEARANCE NOT ACHIEVABLE.
FINISHED SURFACE
REFER TO STANDARD LT300-01 (Dwg C-ES-133-01) AND STANDARD LT300-02 (Dwg C-ES-133-02) FOR ELECTRICAL SUPPLY DETAILS
WALL FIXINGS - M8x100DEEP CHEMICAL ANCHORS
560
370
40
55
195
89
182
265
SUPPLY CABLE PROTECTION COVER SEE STANDARD LT300-02 (Dwg C-ES-160-02)
C-ES-160-01
04/2001
TL
JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
01LT 221
CONSTRUCTION STANDARDLighting and Electrical
WALL MOUNTED
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
TL
RS
80 OD pipe
3030
cut linescentre line
66
4444
89Ø CHS
cut line
5015
00 m
ax c
/cs
as r
equi
red,
che
ch o
n si
te10
gro
und
clea
ranc
e15
00 m
ax c
/cs
1500
max
c/c
s2525
1500
max
c/c
s
as r
equi
red,
che
ck o
n si
te30
025
5050
5030
025
375
50
25
50
25
150
50
2525
5050
35
25
35
50
150
5050
150
255050
2550
39.539.525
2525
EQ
.E
Q.
50150
1350
max
5013
50m
ax50
7979
39.539.5
50 2525
5012
510
012
5
375
100
5050
3030
79
4444
30° 30conduitaccess
30bracket back plate
bracket wall fixing
cover retaining screwsbracket lug
cover
side
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
ALL DIMEMSIONS IN MILLIMETERS.
C-ES-160-02
05/2001
N.T.S.
DRAWN
DESIGNED PR/TL
JR/JB
DATE
DRWG No.
SCALE
CERTIFIED
CHECKED
BracketBottom
wallfixings
VIEW
RS
TL
ELEVATIONSfront
Fixed CoverOne Piece
screwsretaining
BottomBracket
One PieceFixed Cover
BracketsIntermediate
wallfixings
wallfixings
TopBracket
Fixed CoverOne Piece
retainingscrews
Earth stud
IntermediateBrackets
BracketFUSE ANDTERMINAL
BLOCKMOUNTING
ON INSULATINGPANEL
Top
FuseAccessCover
CoverAccess
FITTINGLIGHT
79 x 6 x 375 plate, with 50 deep lugs and 100 deep lugs.Bracket drilled for wall fixing bolts, Galvanised finish.
wall fixing bolts. Galvanised finish.79 x 6 x 150 plate, with 50 deep lugs. Bracket drilled for
Fabricated from 80 OD pipe, welded to bracket plate, tosuit close fit to cover. Drilled and tapped for M4 coverstainless steel retaining screws. Galvanised finish.
drilled and countersunk for M4 countersunk stainless steelFabricated from 89Ø CHS (4 wall thickness), cut in half,
M8 x 100 deep chemical anchors.
cover retaining screws. Finished to match light fitting.
CONSTRUCTION STANDARDLighting and Electrical
WALL MOUNTEDCable Protection
COMPONENTSbracket lugs
Bottom Brackets
Bracket Lugs
Cover
Wall Fixings
Top Bracket
Intermediate and
-
-
-
-
-
02LT 221
cover
PLAN
METAL LID FOR 300 Ø SLEEVE225 Ø NOM. FIBRE CEMENT SLEEVE
DESCRIPTION
4 RA 54875 RA 5476
ITEM STOCK NO. NO.
ETSAETSA
SUPPLIER
32 UNDERGROUND ELECTRICAL ENCLOSURE1 RA 5473 SECURING BOLTS FOR METAL COVER ETSA
UNDERGROUND ELECTRICAL ENCLOSURE COVERCONDUIT TO SWEEP DOWN TO PIT
FUSE PIT
CONDUIT ROUTE IN FOOTPATH
750
CO
VE
R
1200
CO
VE
R
2000 MIN. 2000 MIN.
GROUND LEVEL
225 Ø NOM. ETSA TYPE
ETSA TYPE SECURING BOLTS
PROVIDE APPROX. 1.0M SLACK CABLE
42
1
CONCRETE BLOCKS OR 100mm QUARRY RUBBLE
SECTION
TO SUPPORT SLEEVE
TO ADJACENT LIGHT POLETO NEXT FUSE PIT (IF APPROPRIATE)
1000
FIBRE CEMENT SLEEVE
METAL LID FOR 300 SLEEVE.'ETSA' LETTERING TO BE REMOVED.
5ACC UNDERGROUND ELECTRICAL ENCLOSURE COVERREFER TO STANDARD LT 300-01 (DWG C-ES-133-01)
3
FROM ACC PUBLIC LIGHTING OR ETSA UTILITIES SERVICE POINT(AS APPROPRIATE).
MOUNT SWITCHGEAR ON INSULATED PANEL FIXED TO GALVANISED STEEL TRAY ( BEHIND LIGHTING COLUMN ACCESS COVER)
6mm² COPPER PVC EARTH
ORANGE CONDUIT40 Ø HD UPVC
SWITCHBOARDACC PUBLIC LIGHTING
ACC
COLUMN EARTHING BOLT.EARTH CONNECTIONS BOLT TO BE PROTECTED FROM CORROSION AND TO BE ACCESSIBLE. USE CRIMP JOINTS FOR CONNECTIONS
TO BRASS EARTH STUD ON GALVANISED STEEL TRAY
10A HRC
MAIN SWITCH
ACC FUSE PIT(JOIN EARTHS TO AS3000 REQUIREMENTS)
N
E
AA
E
N
REFER TO STANDARD LT310-03CIRCUITS AS REQUIRED)
2x1c, 6mm² COPPER PVC/PVC ORANGE CIRCULAR CABLE PLUS 6mm² COPPER INSULATED EARTH CONDUCTOR.(This is the minimum size required and a larger size must be used where necessary to meet volt drop and earth resistance requirements to AS3000 and AS3008).
ACTIVE LINK, NEUTRAL LINK & EARTH LINKTO NEXT
FUSE PIT
CLIPSAL BLUE POINTFUSED TERMINAL BLOCK
CABLE TO LANTERN IN 2C+E, 2.5mm² COPPER TPS
SERVICE PIT
UTILITIES
CIRCUIT SIZES ARE MINIMUM. CONSULTANT/CONTRACTOR TO CONFIRM SIZE REQUIRED FOR VOLTAGE DROP CONSIDERATIONS.
C C
(SEPARATE FUSE REQUIRED FOR EACH LIGHT)
NOTE.
(Dwg C-ES 133-04)(Dwg C-ES 133-04)
REFER TO STANDARD LT310-03
C-ES-131-01
05-2001
TL
JR/JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
02LT 700
CONSTRUCTION STANDARDLighting and Electrical
MULTIPLE LIGHTING COLUMNS
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
TL
RS
METHOD AND TYPE OF FIXINGS USED FOR GWP SHALL BE TO APPROVAL OF SUPERINTENDENT.THE INSTALLED PVC BEND AND COUPLING ADAPTOR SHALL BE INSPECTED BY SUPERINTENDENT PRIOR TO BACK FILLING.
GWP (MEDIUM DUTY)ABOVEGROUND
NOM. BORE (W x H x D)FUSE ENCLOSURE
DIMENSIONS OF & TYPE
CABLE SIZE
Cu,PVC/PVCPHASESNo. OF
TYPESERVICE
N E W C O N S U M E R M A I N S S E R V I C E
CAPACITYSERVICE
NOM.SIZE HD UPVC
U/G CONDUIT
40Ø40Ø
32Ø32Ø
65Ø 800 x 370 x 250380 x 300 x 180380 x 300 x 180380 x 300 x 180380 x 200 x 180
50Ø40Ø40Ø
50Ø65Ø
35mm²25mm²16mm²16mm²
332
33
DCB
F E
200AMP100AMP100AMP60AMP60AMP70AMPA 1 16mm² 32Ø 25Ø 380 x 200 x 180
THE PROPOSED GWP AND FUSE ENCLOSURE SHALL BE PAINTEDWITH PRIMER AND TWO COATS OF EXTERIOR PAINT. COLOUR TOMATCH THE WALL OR STRUCTURE THAT EQUIPMENT IS MOUNTED TO.
CONTRACTOR TO LIAISE WITHTELSTRA FOR UTILISING CONSUMERMAINS SERVICE TRENCH
BUILDING
F
BL LB
F O O T P A T H
PR
OP
ER
TY
SP
100mm MIN. CLEARANCE FROM
FUSE ENCLOSURE (PREFERREDON SIDE OF BUILDING)
CONCEAL BEHIND WALL RETURN LOCATE VERTICAL CONDUIT TO
WHERE APPLICABLEOR ADJACENT TO DOWN PIPES
CORNER TO GWP
NOTE
BO
UN
DA
RY
NOTES
(WHERE APPLICABLE)
CONTRACTOR TO LIAISE WITH TELECOMMUNICATIONS AUTHORITY FORSHARING OF CONSUMER MAINS SERVICE TRENCH (WHERE APPLICABLE).
FOR ELEVATIONS, REFER TO STANDARD LT800-02 (Dwg C-ES-150-02) .
C
400
TO NEW ETSA UTILITIES FUSE ENCLOSUREOPTION 1 OPTION 2
TO EXISTING METER SWITCHBOARD
400mm MIN. CLEARANCE FROM
BO
UN
DA
RY
PR
OP
ER
TY
C
BUILDING
F O O T P A T H
LB
SP
BL
MSB
MSB
PROPERTY BOUNDARY TO CONDUIT
1.
2.
3.
4.
5. 95mm²
S C H E D U L E
C-ES-150-01
05/2001
TL
JR/JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
01LT 800
CONSTRUCTION STANDARDLighting and Electrical
UNDERGROUNDING OF PRIVATE PROPERTIESPlan and Schedule
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
TL
RS
600
(MIN
)
UTILITIES SP
GALVANISED WATER PIPE (G.W.P.).REFER TO 'SCHEDULE' ONDWG C-ES-150-01 FOR SIZES TO USE.
REFER TO OPTION 1 OR 2.
COMSUMERS SERVICE MAIN
GROUND LEVEL
THE G.W.P. SHALL BE BENT TO FOLLOW
PAINT TO MATCH STRUCTURE THATTHE GENERAL CONTOUR OF BUILDING.
600 (NOM) WITH ETSA UTILITIES DUCTS300 (NOM) WITHOUT ETSA UTILITIES DUCTS
REFER ATTACHEDACC SPECIFICATION
NOTE1.
ALL SERVICE AUTHORITIES
GROUND LEVEL GROUND LEVEL
ETSA UTILITIES DUCTS,100 Ø (TYPICAL)
BED IN SAND (TYPICAL)
ACC PUBLIC LIGHTING40 Ø (TYPICAL)
750
CO
VE
R
900
CO
VE
R
100
1000
CO
VE
R
900
CO
VE
R
750
CO
VE
R
100
TRENCHTRENCH
600 (NOM)
CO-ORDINATE DUCTING REQUIREMENTS WITH
ACC WHITE COMMUNICATIONSDUCTS 100 Ø (TYPICAL)
600
CO
VE
R
500
CO
VE
R
ACC SPARE 80Ø (TYPICAL) ORANGE HD UPVC ACC SPARE 80Ø (TYPICAL) FOR
TRAFFIC LIGHT USE IF REQUIRED.
BACK FILL MATERIALREFER ATTACHEDACC SPECIFICATION
DUCTS 100 Ø (TYPICAL)ACC WHITE COMMUNICATIONS
ACC ORANGE ELEC. MARKER TAPE
C-ES-140-01
05/2001
TL
JR/JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
01LT 900
CONSTRUCTION STANDARDLighting and Electrical
TRENCHESStreets
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
TL
RS
200W x 100D CONCRETE
ACC ORANGE ELECTRICAL MARKER TAPE
BACK FILL MATERIAL
(15MPa TO AS1480)
PARK LANDS - GENERAL PARK LANDS - PATHWAY LIGHTING
450 (MIN)
REFER ATTACHEDACC SPECIFICATION
NOTE
GROUND LEVEL
900
CO
VE
R
TRENCH
100
100
100
150
ACC PUBLIC LIGHTING40 Ø ORANGE HD UPVC
CONDUIT EMBEDDED IN
BY 50mm SAND50mm SAND & COVERED
TRENCH
600 (NOM)
150
100
100
900
CO
VE
R
50mm SAND & COVEREDCONDUIT EMBEDDED IN
BY 50mm SAND
ACC PUBLIC LIGHTING40 Ø (TYPICAL)
BACK FILL MATERIAL
GROUND LEVEL
ACC SPECIFICATIONREFER ATTACHED
(TYPICAL) ACC 80Ø HD UPVC (SPARE)
(FOR PUBLIC LIGHTING UNDER OR ADJACENT TO PATHWAYS, WHERE CABLE ROUTE IS CLEARLY DEFINED. CONTACT ACC PROJECT MANAGER TO DETERMINE ACCEPTABLE LOCATIONS)IT IS NOT TO BE USED IN EVENT AREAS.
CO-ORDINATE DUCTING REQUIREMENTS WITH ALL SERVICE AUTHORITIES.
PERMANENT CABLE MARKERS REQUIRED AT MAXIMUM SPACING OF 30 METRES FOR LONG STRAIGHT ROUTES AND AT ANY CHANGE OF DIRECTION.
1
2
EVENT AREAS SHALL BE AS PARKLANDS GENERAL, BUT WITH 1500mm COVER.
3
ACC ORANGE ELECTRICAL M
C-ES-141-01
05/2001
TL
JR/JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
02LT 900
CONSTRUCTION STANDARDLighting and Electrical
TRENCHESPark Lands
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.
TL
RS
PARK LANDS - BORED
1000
CO
VE
RGROUND LEVEL
ACC PUBLIC LIGHTING 40Ø ORANGE HD UPVC (TYPICAL)
ACC 100Ø ORANGE HD UPVC DUCT
FOR PUBLIC LIGHTING UNDER OR ADJACENT TO PATHWAYS WHERE CABLE ROUTE IS CLEARLY DEFINED AND TRADITIONAL TRENCHING METHODS ARE NOT PRACTICAL AND/OR MAY CAUSE HARM TO EXISTING VEGETATION.FOR PREFERRED METHOD OF CABLE POSITIONING IN PARK LANDS, SEE STANDARD LT900-02 (Dwg C-ES-141-01).
PERMANENT CABLE MARKERS REQUIRED AT MAXIMUM SPACING OF 30 METRES FOR LONG STRAIGHT ROUTES AND AT ANY CHANGE OF DIRECTION AND AT ANY ENDS OF CONDUIT/CABLE RUN.
CO-ORDINATE DUCTING REQUIREMENTS WITH ALL SERVICE AUTHORITIES.
2
1
NOTE
EVENT AREAS 1500mm COVER.3
(EV
EN
T A
RE
AS
150
0 C
OV
ER
)
C-ES-141-02
05/2001
TL
NS/JB
DATE
DRWG No.
CERTIFIED
CHECKED
N.T.S.SCALE
DRAWN
DESIGNED
03LT 900
CONSTRUCTION STANDARDLighting and Electrical
BORED TRENCHESPark Lands
COPYRIGHTThis document produced by City of Adelaide shall not copied without written consent.