This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
The basic system provides as attractive,affordable and efficient solution for conventionalbulkheads. The system can contribute to thequality of life at sea while meeting structural,safety and budget considerations.
Rw 32dB
3000mm (Max)
※ The technical data could be different from thisedition to give possibil i ty of choosing the level ofsound reduction requirement.
: 150 μm T h k . P V C F i l mWith Protective Foil
D I M E N S I O N S
Thickness
W i d t h
Length
: 50mm
: 600mm (Standard)
: 2200mm (Standard),3000mm (Max)
± 0.5mm
± 0.5mm
± 3mm
The panel system supplied ready for theinstallation complete with assembly profiles. Thestandard width of the panels is 600mm and theheight according to customer requirements.
7
Rw 32dB(Max.43dB)
JOINTING METHOD
※ The technical data could be different from this editionto give poss ib i l i ty of choosing th e level of soundreduction requirement.
HT Panel System is prefabricated in thicknessesof 25 to 50mm utilizing mineral wool insulation for exceptional energy-saving performance andsubstantial reduction of weight. Since, they weighless than standard panel System.
TECHNICAL DATA
Fire Class
Weight
Sound Reduction Index
Thermal Transmittance
: B-15
: 15.7 kg/m2
: 31 d B ( S T C )
: 0.58 kcal/m2h° c
C O N S T R U C T I O N
Core Material
Surface Material
Finish Material
: Mineral WoolDensity 140 k g / m3
: 0.4 mm Thk. Hi-TensioSteel Plate
: 150 μm T h k . P V C F i l mWith Protective Foil
AL50 PANELS are prefabricated using 0.8mm Aluminum plate combined with the selected finishmaterial to create a complete assembly for theinterior walls of any marine application.
Dropping power and communications–neatly andsimply–from up there to down here: that’s whatPrearranged Conduits are all about. Whatever kind of power or communications wiring you needto bring down inside of the wall panel.Conduit Size 100 x 23.5mm
Prearranged metal conduitfor cable can be deliveredupon reqeduest.
TECHNICAL DATA
Fire Class
Weight
Sound Reduction Index
Thermal Transmittance
: B-15
: 18.8 kg/m2
: STC32dB
: 0.58 kcal/m2h° c
C O N S T R U C T I O N
Core Material
Surface Material
F i n i s h
: Mineral WoolDensity 140 k g / m3
: 0.6 mm Thk. Galv ’dSteel Plate
: 150 μm T h k . P V C F i l mWith Protective Foil
C50D Panel System is an economical solution incommercial, special and passenger vessel. Panelsystems can be designed for new construction,renovations, or retrofit projects where a reductionof intrusive noise or reverberation time is required.
TECHNICAL DATA
Fire Class
Weight
Sound Reduction Index
Thermal Transmittance
: B-15
: 21.56 kg/m2
: STC42dB(Max.47dB)
: 0.52 kcal/m2h° c
C O N S T R U C T I O N
Core Material
Surface Material
F i n i s h
: Mineral WoolDensity 200 k g / m3
: 0.6mm Thk. Galv ’dSteel Plate
: 150 μm T h k . P V C F i l mWith Protective Foil
D I M E N S I O N S
Thickness
W i d t h
Length
: 50mm
: 600mm (Standard)
: 2200mm (Standard),3000mm (Max)
± 0.5mm
± 0.5mm
± 3mm
Rw 42dB(Max.47dB)
(Max.33.06kg/m2)
W - C 5 0 D
High Noise Reduction Panel
STANDARD JOINT
JOINTING METHOD
※ The technical data could be different from thisedition to give possibil i ty of choosing the level ofsound reduction requirement.
※ Air gap for installation of cables inHigh Sound Reduction Panel System.
The greater the thickness, the higher theacoustical absorption(STC rating). The standardswidth of the panels is 600mm and the heightaccording to the customer requirements.
TECHNICAL DATA
Fire Class
Weight
Sound Reduction Index
Thermal Transmittance
: B-15
: 23.2kg/m2
: STC43dB
: 0.49kcal/m2h° c
C O N S T R U C T I O N
Core Material
Surface Material
Finish
: Mineral WoolDensity 140kg/m 3
: 0.6mm Thk. Galv ’ dSteel Plate
: 150μm Thk. PVC FilmWith Protective Foil
D I M E N S I O N S
Thickness
Width
Length
: 50mm
: 600mm (Standard)
: 2200mm (Standard),
± 0.5mm
± 0.5mm
± 3mm
Rw 43dB
3000mm (Max)
※ The technical data could be different from thisedition to give possibility of choosing the level ofsound reduction requirement.
STACO manufactures High Noise ReductionPanels and Specialty Products, all of which aredesigned to help drastically reduce distractingnoise. We work closely with professional designersand are able to produce a large variety of custompanels to suit every decor.
TECHNICAL DATA
Fire Class
Weight
Sound Reduction Index
Thermal Transmittance
: B-15
: 27.33 kg/m2 (Max.37.42)
: STC46dB (Max.52dB)
: 34kcal/m2h° c
C O N S T R U C T I O N
Core Material
Surface Material
Finish
: Mineral WoolDensity 140kg/m 3
: 0.6mm Thk. Galv ’ d SteelPlate
: 1 5 0 μm T h k . P V C F i l mWith Protective Foil
B Clip Joint Panels use rigid mineral wool asprimary, nonflammable core material. The panelelements are assembled with a Clip Joint, whichgives great advantages like dismount, stability,flexibility and is easy to replace.
TECHNICAL DATA
Fire Class
Weight
Sound Reduction Index
Thermal Transmittance
: B-0
: 13.48 kg/m2
: STC32dB
: 1.06 kcal/m2h° c
C O N S T R U C T I O N
Core Material
Surface Material
Finish Material
: Mineral WoolDensity 140 k g / m3
: 0.6 mm Thk. Galv ’dSteel Plate
: 150 μm T h k . P V C F i l mWith Protective Foil
B type panel is a fast, easy and cost effectivemethod to lock in place of wall panel, acousticalpanel, and partition. The "U" shaped clips wedgetogether locking panels in place. It provides for easy and fast future removal or dismounting of panels, etc., for change of replacement.
TECHNICAL DATA
Fire ClassWeight
Sound Reduction Index
Thermal Transmittance
: B-15: 17.5 kg/m2
: STC32dB
: 0.58 kcal/m2h° c
C O N S T R U C T I O N
Core Material
Surface Material
Finish Material
: Mineral WoolDensity 140 k g / m3
: 0.6 mmThk. Galv ’d
Steel Plate
: 150 μm T h k . P V C F i l mWith Protective Foil
A type panel system is an easy-to-install wallsystem that withstands impact and abrasion.Made of mineral wool core and structurallyreinforced H-Profile Connection, it is available in avariety of thickness to meet the needs of fire classzoning and other requiring minimal maintenanceand strict weight controls.
: 150 μm T h k . P V C F i l mWith Protective Foil
D I M E N S I O N S
Thickness
W i d t h
Length
± 0.5mm
± 0.5mm
± 3mm
: 50mm
: 500~600mm (Standard)
: 2200mm (Standard),3000mm (Max)
Marine codes require that interior bulkheadproducts meet a Class A, B, or C fire rating. Atype panel system is the strongest panel in theindustry due to its high All Class fire rating.
STACO A-60 Class Fire Rated Panels is as aninterior partition, instead of non-bearing steelbulkhead. This wall offers a flat surface on sides,using a PVC film finish, eliminating the need for painting in the field and eliminating costly designdead load.
TECHNICAL DATA
Fire Class
Weight
Sound Reduction Index
Thermal Transmittance
: A-60
: 25.67kg/m2(Max.31.90)
: STC33dB (Max.46dB)
: 0.31 kcal/m2h° c
C O N S T R U C T I O N
Core Material
Surface Material
F i n i s h
: Mineral Wool
: 0.6 mmThk. Galv ’d SteelP l a t e
: 150 μm T h k . P V C F i l mWith Protective Foil
D I M E N S I O N S
Thickness
W i d t h
Length
: 100mm
: 600mm (Standard)
: 2200mm (Standard),3000mm (Max)
± 0.5mm
± 0.5mm
± 3mm
Rw 33dB (Max.45dB)
Inner Part : Density 140 Kg/m3Joint Part : Density 280 Kg/m3
Inspection Doors and hatches provide ascientifically designed, mechanically efficientclosure, which provides immediate access to bothwall and ceiling panel and easily andeconomically installed.