Stability Studies to Support PET Drug Applications Danny Bingham Director PET cGMP Compliance Triad Isotopes © 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 1
21

Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Feb 06, 2018

Download

Documents

ngoque
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Stability Studies to Support PET Drug Applications

Danny BinghamDirector PET cGMP Compliance

Triad Isotopes

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 1

Page 2: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Objective

My objective is to provide information to help you decide the best stability study practices for your submission. We will discuss the following:

• Review the purpose for stability studies• Review what to include in stability studies• Process development/control relationship to stability studies• Vial size and orientation considerations• Expiration time• Elevated temperatures and other considerations

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 2

Page 3: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

What are Stability Studies?

Stability studies are used to confirm the drug product is:

• stable under the defined storage conditions • stable at the highest radioactive concentration• stable at expiration time

The entire batch volume is stored in the intended container/closure for the duration of the study.

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 3

Page 4: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Stability Studies

Stability studies address concerns due to: • Radiation-related radiolysis• Chemical changes

– Interaction between drug product components and vial/stopper– Ability of container/closure to protect against contamination

(container/closure integrity)

Analytical methods must distinguish degradation products and impurities• Process development and process controls – impurity profile

– Analytical method development/validation

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 4

Page 5: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Stability Studies – New Submission

Three stability batches (qualification batches) are provided in the initial submission– Should be performed on three consecutive business days –

adequate planning– Why not all in one day?

• ALARA concerns• Logistics – difficult to perform 3 stability batches in one day (especially

for F-18 products)• You are not involving parts of the quality system that may impact the

chemical profile. For example:

– Daily reagent/diluent preparation– Daily chemistry module set-up/cleaning– Formulation dilution– Daily mobile phase preparation– Cleaning

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc.5

Page 6: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Stability Studies – New Submission

Stability program is described in your submission• Includes a summary paragraph• Table summarizing QC tests and stability indicating tests for

the product– Summary of the stability batch data.

• Post-approval commitment– Single stability study performed annually

How do I develop the program?• What are your goals?

– Derived from process development

• Once these are defined then the protocol can be written.

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 6

Page 7: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

What do I need to include in stability studies?

The stability protocol typically consists of the following:

1. Summary/purpose, Schedule, Procedure 2. Full QC at T0 (as defined in your submission)3. Perform stability indicating tests at defined time points:

• Radiochemical identity and purity• Radionuclidic purity• Appearance• pH• Stabilizer/preservative effectiveness• Chemical purity• Specific activity (if necessary)

4. Summary report• Includes complete and legible batch records

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 7

Page 8: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Best Practices

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 8

Page 9: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Best Practices

– Appearance– pH– Radiochemical purity

and identity– Stabilizer/preservative

effectiveness– Chemical purity– Specific activity (if

necessary)– Radionuclidic purity– Endotoxin testing– Sterility testing

If you claim it then prove it.• Most CMC review questions answered

with process development data…

Best practices for stability study QC testing begins with process development.• Establishes which QC and stability

indicating tests to perform (or not perform)

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc.9

Page 10: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Best Practices

Processdevelopment

Drug product:Radionuclide mfgLabeling reactionDeprotection reactionPurification (semi-prep)Final formulation

Impurity profile:Specs. determinedQC/stability testing

Validated analytical methods

Defendable stability

study program

Defendable stability study

protocol

Successful stability studies

Analytical method

development

Year after year after

year…

Precursor characterization is also a consideration for new products or syntheses…

Described in CMC section

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 10

Page 11: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Best Practices – Precursor Stability

Precursor synthesis

Process controls for

precursor mfg.

Precursor characterization

Precursor acceptance

specifications (appearance, ID,

purity)

Precursor stability studies

Contributes to the final drug

product impurity profile.

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 11

Page 12: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Best Practices – Process Development

Take the time to ensure process development is adequate:

• There is value in “justifying the ruggedness” of a process with a certain number of batches before finalizing your CMC section.

– Especially for complex syntheses

– Finalize process controls/stability program

– The stability batches must be performed using the process submitted in the application

– Do not want to be in the position of amending the CMC section of an application during review

• This will require the stability study/qualification batches to be repeated

• Provides support for expiration time and time points.

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 12

Page 13: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Best Practices – Expiration

What about expiration time?• Decision is based on stability goals - process development

– A good starting point for new products is 6 half-lives

Which time points should I use for stability testing?

• An additional time point may be needed– For example: t0, t6, t12

– Decision is based on process development/process controls

• Well studied products (for example FDG, NaF, ammonia) have used two points: EOS (t0) and texpiry

– Two points have been used successfully for IND drug products

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 13

Page 14: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

What About Vial Orientation?

Should vials be stored upside down or right side up?

Stability studies should be performed with inverted configuration• Formulation is in contact with all surfaces of the container/closure

– Interaction between drug product components and vial/stopper

– Container/closure integrity

– Specified in the PET drug application guidance “Sample Formats – Chemistry, Manufacturing, and Controls (CMC) Section” for FDG, NaF, ammonia.

Upright configuration may be acceptable. • Justify in the application

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 14

Page 15: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

What About Vial Size?

Do you need to perform stability studies on each vial size used in PET drug manufacturing?

The PET Q&A Guidance for PET Drugs (Dec 2012) addresses this (Q68):• Recommends that the largest vial size be used

• If you manufacture in 30 mL and 50 mL vials, then use 50 mL vials– May need to test the 30 mL vial if the headspace oxygen-to-surface ratio differs

significantly

– If you manufacture into 30 mL vials and want to use 50 mL vials, then new stability studies will be required (in triplicate)

• Will require a prior-approval supplement for a change in the container closure.

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 15

Page 16: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Other Considerations

Elevated temperature study – necessary?

• Likely not needed

– PET Q&A Guidance for PET Drugs (Dec 2012) Q69: not required for commonly used PET drugs (e.g. FDG, NaF, ammonia)

– New drug products: may need to consider elevated temperatures.

• Especially if shipped long distances• Use process development data to justify your position.

• Other stability considerations

– Product is photosensitive

Discuss with FDA review division – For example, end of Phase 2© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 16

Page 17: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Other Considerations

Stability studies to be performed in triplicate for:– Change in strength– Change in stabilizer/preservative content– Change in final product container/closure– Change in storage conditions– Change in expiration time– Addition of a precursor manufacturer– Addition of a target material manufacturer (for example, [18O]water)

Submitted as an annual report, CBE or prior approval supplement as appropriate.

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 17

Page 18: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Documentation

Lack of good documentation practices is a frequent cause of stability study issues during internal reviews

Some errors have resulted in the rejection of a stability batch.• A thorough review at T0 and Texpiry will save time correcting mistakes

– or starting over• Second person review critical

Risk during FDA review…

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 18

Page 19: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Documentation

Consider the following good documentation practices:

1. Clear – Must be legible

2. Traceable – (who, what, when, where, why)

3. Accurate – Avoid transcription errors

4. Complete – The record must be complete with all attachments

5. Reviewed – Timely and detailed review of the batch record is critical – Errors detected can be immediately corrected

– Procrastination can lead to exasperation

– Annotated properly – Single line through/date/initial and explanation

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 19

Page 20: Stability Studies to Support PET Drug Applications · PDF file01.07.2017 · Objective My objective is to provide information to help you decide the best stability study practices

Summary

Best practices are derived from process development and can be used to support/justify these stability study goals:• Impurity profile - analytical methods must distinguish degradation

products/impurities• Vial orientation• Expiration time• Elevated temperatures/photosensitivity/other

Stability program - defines t0 and texpiry stability testing to perform, or not to perform• Consistent with goals• Stability protocol derived from the stability program• If you claim it, prove it

Good documentation practices are important• Don’t jeopardize your study (or submission) with errors• A 30 minute detailed review can save hours of time

© 2017 by Triad Isotopes, Inc. This document is not for distribution without the written consent of Triad Isotopes, Inc. 20