Top Banner
Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for Use in Landfill Redevelopment Joseph J. Nemesh, P.E. Cornerstone Environmental Group, LLC © 2016 Cornerstone. All rights reserved.
29

Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Aug 07, 2018

Download

Documents

trinhnhu
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Building lifetime relationshipswith our clients and employees.

Spray Applied Membranes –

Practical Considerations for Use in

Landfill RedevelopmentJoseph J. Nemesh, P.E.Cornerstone Environmental Group, LLC

© 2016 Cornerstone. All rights reserved.

Page 2: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Landfill Redevelopment?

• Landfills can be productively reused similar tobrownfields

• Creative opportunities for reuse

• Financial incentives

• >$1 billion tax credits since 2003 in NY

• Integrate remediation with redevelopment

© 2016 Cornerstone. All rights reserved.2

Page 3: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Landfills – Desirable Waterfront Properties

© 2016 Cornerstone. All rights reserved.3

Page 4: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Example List of Landfill Developments

© 2016 Cornerstone. All rights reserved.

NJDEP 2009 Presentation “Innovative Approaches to Landfill Redevelopment” Frank McLaughlin

Retail / Commercial Sites 28 completed 20 underway

Mixed Residential / Commercial Sites 9 completed 11 underway

4

Ashbrook Farm Edison, NJ Residential

Atlantic City Landfill Atlantic City, NJ Retail / Commercial

Federal Business Center Woodbridge, NJ Commercial

Former Emerson Street Landfill Rochester, NY Commercial / Industrial / School

Jersey Gardens Mall Elizabeth, NJ Retail / Commercial

Metlife Standium East Rutherford, NJ Sports Complex

Passaic County Community College Wanaque, NJ School

Salvation Army Kroc Center Camden City, NJ Commercial

Seaboard Point Report North Wildwood, NJ Residential

Somerville Landfill Somerville, NJ Planned Mixed Commercial / Residential

Xchange at Secaucus Junction Secaucus, NJ Mixed Commercial / Residential

Page 5: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Vapor Intrusion?

© 2016 Cornerstone. All rights reserved.

• Subsoil vapors couldaccumulate in occupiedareas of the building,resulting in:

• Short term safety hazards(explosion)

• Acute health effects (typicaloverexposure symptoms)

• Aesthetic problems (odors)

• Choric health effects due tolong-term exposure to lowlevel vapor concentrations

Source: US EPA.

5

Page 6: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Former Emerson Street Example

© 2016 Cornerstone. All rights reserved.6

Page 7: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Former Emerson Street Example

© 2016 Cornerstone. All rights reserved.7

Page 8: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Former Emerson Street Example

© 2016 Cornerstone. All rights reserved.8

Page 9: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Typical Vapor Intrusion Mitigation Design

© 2016 Cornerstone. All rights reserved.9

Page 10: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Gas Barrier Membranes

• Sheet Liners (HDPE, Specialty Co-Extruded)

© 2016 Cornerstone. All rights reserved.

Photo courtesy of W. R. Meadows.

10

Page 11: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Typical Sub-Slab Site Conditions

© 2016 Cornerstone. All rights reserved.11

Page 12: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Gas Barrier Membranes

• Sheet Liners (HDPE, Specialty Co-Extruded)

• Spray Applied Membranes (Liquid Boot, GeoSeal)

© 2016 Cornerstone. All rights reserved.12

Page 13: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Case Study - False Positive GasDetections Above Membrane

© 2016 Cornerstone. All rights reserved.13

• Provides gas monitoring above membrane without sensors in first floor(important for residential application)

• Eliminates issues related to settlement. Membrane and monitoringlayer bonded to slab

Page 14: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Case Study - False Positive GasDetections Above Membrane

• Monitoring system located betweenmembrane and bottom of building slab.

• Operation data indicated sporadic methanedetections above membrane.

• Methane not detected within first flooroccupied space.

• High vacuum sampling pump(20 – 40 inches water)

• Low vacuum gas collection system(~0.2 – 0.02 inches water)

• Vacuum differential promoting gasmovement through membrane imperfections

© 2016 Cornerstone. All rights reserved.14

Page 15: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Typical Membrane CQA

• Smoke testing after installation

• Thickness testing (caliper, “boot test”)

© 2016 Cornerstone. All rights reserved.15

Page 16: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Implementation of Non-Typical CQA

• Comprehensive visual/physical inspection

• After placement of protective geotextile and slabreinforcement

• Second smoke test after slab reinforcement installed

• Visual inspection immediately to slab pour

© 2016 Cornerstone. All rights reserved.16

Page 17: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Unexpected Results

© 2016 Cornerstone. All rights reserved.17

Page 18: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Imperfection Frequency

© 2016 Cornerstone. All rights reserved.18

Page 19: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Identified Membrane Imperfections

© 2016 Cornerstone. All rights reserved.

Separation from pipehanger

19

Damage from rebar cutting

Page 20: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Identified Membrane Imperfections

© 2016 Cornerstone. All rights reserved.

Diffuse smoke from overspray notcured to underlying thin membrane

20

Overspray not cured to underlyingthin membrane

Page 21: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Identified Membrane Imperfections

© 2016 Cornerstone. All rights reserved.

Cured membrane dissolved byconcrete release agent

Gravel causing shadowing

21

Page 22: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Cold Weather Application?

• Application temperature, 40F minimum

• Potentially brittle below freezing

© 2016 Cornerstone. All rights reserved.22

Page 23: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Something New? Ventilated Floor System

© 2016 Cornerstone. All rights reserved.

Photo courtesy of Geoplast

23

Page 24: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Ventilated Floor System

• Modulo, Cupolex, and other similarconcrete forms

• Continuous void space, uniformvacuum field

• Low energy required to generatevacuum field

• 4 inch to 24 inch forms

• Able to reduced fill required belowbuilding

• Reduced concrete andreinforcement

• Robust construction

© 2016 Cornerstone. All rights reserved.24

Photo courtesy of Geoplast

Page 25: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

System Comparison

© 2016 Cornerstone. All rights reserved.25

Barrier SystemTypical Sub-Slab Components

for VI SystemCosts, per

square foot

Range in TotalSystem Costs1

per square foot

Advantages Disadvantages

Sheet Membrane

40 mil LLDPE membrane w/ 8ozgeotextile

$3.00

$4.10Better penetration resistance thanspray-applied liners, better chemicalvapor resistance than spray appliedmembrane

More lengthy to install. Post buildingconstruction repairs more difficultthan spray applied membrane.

Pipe Boots ($150 ea/penetration)2 $0.45

Geovent gas collection pipe3 $0.30

3 inch gravel membrane protection layer $0.35

Spray AppliedMembrane

60 mil Liquid Boot w/protection fabric $4.50

$4.80 Quick to install

Penetrations susceptible to damage,may absorb chlorinated solvents(swell) overtime, potentiallyincreasing emissions.Geocomposite gas collection pipe3 $0.30

Ventilated Floor

Ventilated Floor Blocks, 8 inches tall $3.45

$4.10 $3.25

Provides for more effective gascollection system (easier to achievevacuum distribution, small fan thanother systems), 8 inch less sub-grade stone required. Potential toreduce slab thickness due to blockstructural properties (spread footingbuildings only).

Requires additional sealing aroundpenetrations following concrete slabcure. Post building constructionrepairs more difficult than sprayapplied membrane. Potentially lesseffective barrier during passivesystem operation.

Additional concrete required due to blockshape

$0.50

Penetration sealing after slab pour 2 $0.15

Potential deduct for sub-grade stonesavings

-$0.85

Note:

1 Costs for sub-slab portions of system.

2 Assume 50 penetrations and 17,000 SF building footprint

3 Based on 25 foot row spacing and 17,000 SF building footprint

Page 26: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Interesting Use - Flood Protection

© 2016 Cornerstone. All rights reserved.26

Photo courtesy of Geoplast

Photo courtesy of River Terminal Development Co.

Page 27: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Interesting Use - Concrete Pavement

© 2016 Cornerstone. All rights reserved.

Source:FIELD EVALUATION OF CUPOLEX® AS AN INNOVATIVECONCRETE PAVEMENT TECHNOLOGYAleks Kivi, University of Waterloo, 2013

27

Page 28: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

Summary

• Landfills represent potential redevelopmentopportunities

• Protection of human health is key

• Technology is available to meet these needs

• It’s not rocket science, or is it?

Comprehensive construction quality control programrequired

© 2016 Cornerstone. All rights reserved.28

Page 29: Spray Applied Membranes – Practical Considerations … · Building lifetime relationships with our clients and employees. Spray Applied Membranes – Practical Considerations for

© 2016 Cornerstone. All rights reserved.

Joseph J. Nemesh, P.E.Cornerstone Environmental Group, LLC

[email protected]

Phone: (845) 695-0261

Contact Information

Questions?

29