SH-1 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. Effective 1/1/17 22-8301-30 Split System Heat Pumps Summary of System Ratings IMPORTANT: This table is intended as an at-a-glance overview. See AHRI for complete and up-to-date indoor and outdoor system ratings by model. Not all matches will attain ratings shown below. Model Not Offered NA-System Combination "Not Allowed" XR14 XR14 - 14 SEER Single Stage Heat Pump and Air Handler Ratings Summary ( up to 14 SEER / 12 EER / 8.5 HSPF) 1.5 Ton 2 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 5 Ton SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF TEM / TMM Air Handlers TEM4 14.00 11.50 8.50 14.00 11.50 8.50 14.00 11.50 8.50 14.00 11.50 8.50 14.00 11.50 8.50 14.00 11.50 8.50 14.00 11.50 8.50 TMM4 NA 14.00 11.50 8.20 14.00 11.50 8.50 NA NA NA NA TMM5 14.00 11.50 8.50 14.00 11.50 8.50 14.00 11.50 8.50 14.00 12.00 8.20 NA NA NA TEM6 NA 14.50 12.00 8.50 14.50 12.00 8.50 14.50 12.00 8.50 14.50 12.00 8.50 14.00 12.00 8.50 14.50 12.00 8.50 Hyperion™ Air Handlers GAF2 14.00 11.50 8.50 14.00 11.50 8.50 14.00 12.00 8.50 14.00 12.00 8.20 NA NA NA TAM4 14.00 11.50 8.50 14.00 11.50 8.50 14.00 11.50 8.50 14.00 11.50 8.20 NA 14.00 11.50 8.50 14.00 11.50 8.50 GAM5 14.50 12.00 8.50 14.50 12.00 8.50 14.50 12.00 8.50 14.50 12.00 8.50 14.50 12.00 8.50 14.00 12.00 8.50 14.00 11.70 8.50 TAM7 14.50 12.00 8.50 14.50 12.00 8.50 14.50 12.00 8.50 14.50 12.00 8.50 14.50 12.00 8.50 14.50 12.00 8.50 14.50 12.00 8.50 XR15 XR15 - 15 SEER Single Stage Heat Pump and Air Handler Ratings Summary ( up to 15 SEER / 12.5 EER / 9.5 HSPF) 1.5 Ton 2 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 5 Ton SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF TEM / TMM Air Handlers TEM4 15.00 12.50 8.50 15.00 12.50 8.50 14.25 12.00 8.50 14.50 12.00 8.50 NA NA NA TMM4 NA 14.00 11.50 8.20 14.00 11.50 8.50 NA NA NA NA TMM5 15.00 12.50 8.50 15.00 12.50 8.50 15.00 12.50 8.50 NA NA NA NA TEM6 15.00 12.50 8.85 15.00 12.50 9.00 15.00 12.50 9.50 15.00 12.50 9.50 15.00 12.50 9.50 15.00 12.50 9.50 15.00 12.50 9.50 Hyperion™ Air Handlers GAF2 15.00 12.50 8.50 15.00 12.50 8.50 15.00 12.50 9.50 NA NA NA NA TAM4 15.00 12.50 8.50 15.00 12.50 9.00 14.50 12.00 9.00 14.25 12.00 9.00 14.50 12.00 8.50 15.00 12.00 8.50 14.50 12.00 8.50 GAM5 15.00 12.50 8.50 15.00 12.50 9.00 15.00 12.50 9.50 15.00 12.50 9.50 15.00 12.50 9.00 15.00 12.50 8.50 14.50 12.00 8.50 TAM7 15.00 12.50 9.00 15.25 12.50 9.00 15.25 12.50 9.50 15.00 12.50 9.50 15.00 12.50 9.50 15.00 12.50 9.00 15.00 12.50 9.00 XR16/XL16i XR16/XL16i - 16 SEER Single Stage Heat Pump and Air Handler Ratings Summary ( up to 16 SEER / 13 EER / 9.6 HSPF) 1.5 Ton 2 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 5 Ton SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF TEM / TMM Air Handlers TEM3 NA 14.00 11.50 8.20 NA NA NA 14.00 11.50 8.20 14.00 11.50 8.20 TEM4 15.00 12.50 8.50 15.00 12.00 8.20 15.00 12.00 8.20 NA 15.00 12.00 8.20 14.75 12.00 8.20 TMM5 16.00 13.00 9.00 16.00 13.00 8.50 NA NA TEM6 16.00 12.50 9.00 16.00 13.00 9.60 16.00 13.00 9.60 16.00 13.00 9.60 16.00 13.00 9.60 16.00 13.00 9.60 15.00 12.50 9.00 Hyperion™ Air Handlers GAF2 16.00 13.00 8.55 14.00 12.00 8.20 NA NA NA NA NA TAM4 15.00 12.50 8.55 15.00 12.50 8.20 NA 14.75 12.50 8.50 15.00 12.00 8.50 15.00 12.00 8.50 15.00 12.00 8.50 GAM5 16.00 13.00 8.55 16.00 12.50 9.00 16.00 12.50 9.00 16.00 12.50 9.00 16.00 12.50 9.00 16.00 12.50 9.00 14.50 12.00 8.20 TAM7 17.00 13.00 9.00 17.00 13.50 9.50 17.00 13.50 9.60 16.00 13.00 9.60 17.00 13.50 9.60 16.00 13.00 9.50 15.00 12.50 9.00 Model Not Offered Split System Heat Pumps
10
Embed
Split System Heat Pumps Summary of System Ratings · XR17-2 Stage XR17 - Two Stage 17 SEER Heat Pump and Air Handler Ratings Summary ( up to 17.75 SEER / 13.5 EER / 9.6 HSPF) 1.5
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
SH-1
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Effective 1/1/1722-8301-30
Split System Heat Pumps Summary of System Ratings
IMPORTANT:
This table is intended as an at-a-glance overview. See AHRI for complete and up-to-date indoor and outdoor system ratings by model. Not all matches will attain ratings shown below.
Model Not Offered
NA-System Combination "Not Allowed"
XR14XR14 - 14 SEER Single Stage Heat Pump and Air Handler Ratings Summary ( up to 14 SEER / 12 EER / 8.5 HSPF)
1.5 Ton 2 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 5 TonSEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Effective 1/1/1722-8301-30
XR17-2 StageXR17 - Two Stage 17 SEER Heat Pump and Air Handler Ratings Summary ( up to 17.75 SEER / 13.5 EER / 9.6 HSPF)
1.5 Ton 2 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 5 TonSEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF
TEM Air Handlers TEM6 NA 17.00 12.50 8.50 NA 17.00 12.50 9.60 NA 17.00 12.50 9.60 15.00 12.00 9.60
Hyperion™ Air Handlers
GAM5 NA 16.00 12.50 9.00 NA 16.00 12.50 9.00 NA 16.00 12.00 9.00 15.00 11.00 9.00
TAM7 NA 17.00 13.00 8.50 NA 17.00 13.00 9.00 NA 17.00 13.00 9.50 16.00 12.50 8.50
TAM8 NA 17.25 13.50 9.60 NA 17.75 13.00 9.20 NA 17.25 12.50 9.00 16.25 12.00 9.00
XL18-2 StageXL18 - Two Stage 18 SEER Heat Pump and Air Handler Ratings Summary ( up to 18.0 SEER / 13 EER / 9.5 HSPF)
1.5 Ton 2 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 5 TonSEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF
TEM Air Handlers TEM6 NA 17.00 12.50 8.50 NA 17.00 12.50 9.60 NA 17.00 12.50 9.60 15.00 12.00 9.60
Hyperion™ Air Handlers
GAM5 NA 16.00 12.50 9.00 NA 16.00 12.50 9.00 NA 16.00 12.00 9.00 15.00 11.00 9.00
TAM7 NA 17.00 13.00 8.50 NA 18.00 13.00 9.50 NA 17.00 13.00 9.50 16.00 12.50 8.50
TAM8 NA 17.25 13.50 9.60 NA 18.00 13.00 9.50 NA 17.25 12.50 9.00 16.25 12.00 9.00
XV18-TruComfort™XV18 - TruComfort™ Variable Speed Heat Pump and Air Handler Ratings Summary ( up to 18 SEER / 13.5 EER / 10.0 HSPF)
1.5 Ton 2 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 5 TonSEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF
Hyperion™ Air Handlers TAM8 NA 18.00 13.00 10.00 NA 18.00 13.00 10.00 NA 18.00 12.50 10.00 18.00 12.50 10.00
XV20-TruComfort™XV20 - TruComfort™ Variable Speed Heat Pump and Air Handler Ratings Summary ( up to 21.0 SEER / 13.5 EER / 10.0 HSPF)
1.5 Ton 2 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 5 TonSEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF SEER EER HSPF
Hyperion™ Air Handlers TAM8 NA 19.25 13.75 10.00 NA 21.00 13.50 10.00 NA 19.25 12.50 10.00 19.00 12.70 10.00
Split System Heat Pumps Summary of System Ratings
IMPORTANT:
This table is intended as an at-a-glance overview. See AHRI for complete and up-to-date indoor and outdoor system ratings by model. Not all matches will attain ratings shown below.
Sp
lit S
yste
m H
eat
Pu
mp
s
SH-3
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Effective 1/1/1722-8301-30
TruComfort™ Variable Speed Heat Pumps Single Phase – 2-5 Tons
Table SH-3-A — XV20i R-410A Split System Variable Speed Heat Pump (25–100% capacity)—with ComfortLink™ II1 Uncrated Shipping Line Size (in)
Model Power Dimensions(in.) Weight Sound** Rating Max. OD ODNumber Supply H W D (lbs.) (Cool) (Heat) MCA* Fuse* Gas Liq.
1 Must use TCONT850 or TZONE950 control. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with AHRI Standard 270-2008 (Min/Max when applicable).
XV20i(Variable Speed)
XV18(Variable Speed)
Sp
lit System
Heat P
um
ps
SH-4
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Effective 1/1/1722-8301-30
TruComfort™ Variable Speed Heat Pumps Single Phase – 2-5 Tons
XV20i XV18 Table SH-4-A — Features (4TWV0) (4TWV8)• SEER up to ......................................................................................................................................................................... 21.00 18.00• HSPF up to ......................................................................................................................................................................... 10.00 10.00• Climatuff™ compressor ...................................................................................................................................................... 1 1• Number of stages ................................................................................................................................................................. Variable Variable• Comfort-R™ mode approved .............................................................................................................................................. ✔ ✔• ComfortLink™ II system ..................................................................................................................................................... ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof .......................................................................................................... ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ....................................................... ✔ ✔• Spine Fin™ coil ................................................................................................................................................................... ✔ ✔• Weatherguard™ II top ......................................................................................................................................................... ✔ —• Compressor sound enclosure .............................................................................................................................................. ✔ ✔• Compressor sump heat ........................................................................................................................................................ ✔ ✔• Factory supplied charge ...................................................................................................................................................... R-410A R-410A• Glossy corrosion resistant finish .......................................................................................................................................... ✔ ✔• High pressure switch ............................................................................................................................................................ ✔ ✔• Low pressure protection ....................................................................................................................................................... ✔ ✔• Internal high / low pressure & temperature protection ......................................................................................................... ✔ ✔• Liquid line filter drier - factory installed or factory supplied for field install ........................................................................... ✔ ✔• Start kit-factory installed ....................................................................................................................................................... NA NA• Seacoast shield - factory installed ....................................................................................................................................... ✔ —• Tarpaulin gray cabinet .......................................................................................................................................................... ✔ ✔• 12-year registered limited warranty on compressor, 10-year on outdoor coil & all other functional parts (Residential Use)1 ....................................................................................... ✔ ✔• Extended warranties available .......................................................................................................................................... ✔ ✔
Table SH-4-B — Optional AccessoriesModel Number Description Shipping Weight
Comfort Controls — See Comfort Controls/Zone Sensors Section1 Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at trane.com or by phone at 800-554-6413; otherwise Trane Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on Comfortsite.com.2 Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information.
Sp
lit S
yste
m H
eat
Pu
mp
s
SH-5
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Effective 1/1/1722-8301-30
Effective 1/1/17
Table SH-5-A — XL18i R-410A Split System Two Stage Heat Pump (70/100% capacity) Nom. Cap. Uncrated Shipping Line Size (in)
Model Power Cooling Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) H W D (lbs.) Rating MCA* Fuse* Gas Liq.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with AHRI Standard 270-2008 (Min/Max when applicable).
Split System Heat Pumps Single Phase – 1½-5 Tons
XL18i(Two Stage)
XL16
XL16i(Single Stage)
Sp
lit System
Heat P
um
ps
SH-6
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Effective 1/1/1722-8301-30
Effective 1/1/17
Split System Heat Pumps Single Phase – 1½-5 Tons
XL18i XL16iTable SH-6-A — Features (4TWX8) (4TWX6)• SEER up to ........................................................................................................................................................................ 18.00 17.00• HSPF up to ......................................................................................................................................................................... 9.5 9.6• Climatuff™ compressor .................................................................................................................................................... 1 1• Number of stages ............................................................................................................................................................... 2 1• Comfort-R™ mode approved ............................................................................................................................................ ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof ........................................................................................................ ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ................................................ ✔ ✔• Spine Fin™ coil ................................................................................................................................................................. ✔ ✔ • Weatherguard™ II top ....................................................................................................................................................... ✔ ✔• Electronic Expansion Valve (EEV) ..................................................................................................................................... ✔ — • Compressor sump heat - factory installed ......................................................................................................................... ✔ —• Factory supplied charge .................................................................................................................................................... R-410A R-410A• Glossy corrosion resistant finish ........................................................................................................................................ ✔ ✔• High pressure switch .......................................................................................................................................................... ✔ ✔• Low pressure switch ........................................................................................................................................................... ✔ ✔• Liquid line filter drier - factory installed or field supplied .................................................................................................... ✔ ✔• Seacoast shield - factory installed ..................................................................................................................................... ✔ ✔• Tarpaulin gray cabinet ........................................................................................................................................................ ✔ ✔• 12-year registered limited warranty on compressor, 10-year on outdoor coil & all other functional parts (Residential Use)1 ..................................................................................... ✔ ✔• Extended warranties available ........................................................................................................................................ ✔ ✔
Table SH-6-B — Optional AccessoriesModel Number Description Shipping Weight
Comfort Controls — See Comfort Controls/Zone Sensors Section1 Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at trane.com or by phone at 800-554-6413; otherwise Trane Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on Comfortsite.com.2 Do not use with programmable thermostats.3 Activated on Power Off.4 Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information.
Sp
lit S
yste
m H
eat
Pu
mp
s
SH-7
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Effective 1/1/1722-8301-30
Effective 1/1/17
XR15(Single Stage)
XR14(Single Stage)
Split System Heat Pumps Single Phase – 1½-5 Tons
Table SH-7-A — XR17 R-410A Split System Two Stage Heat Pump (70/100% capacity) Nom. Cap. Uncrated Shipping Line Size (in)
Model Power Cooling Dimensions(in.) Weight Sound** Max. OD ODNumber Suppy (BTUH) H W D (lbs.) Rating MCA* Fuse* Gas Liq.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with AHRI Standard 270-2008.
XR16(Single Stage)
XR17(Two Stage)
COMING SOON - Q1 2017
Sp
lit System
Heat P
um
ps
SH-8
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Effective 1/1/1722-8301-30
Effective 1/1/17
Split System Heat Pumps Single Phase – 1½-5 Tons
XR17 XR16 XR15 XR14Table SH-8-A — Features (4TWR7) (4TWR6) (4TWR5) (4TWR4)• SEER up to ........................................................................................................................................ 17.25 17.00 15.00 14.50• HSPF up to ......................................................................................................................................... 9.60 9.60 9.50 8.50• Climatuff™ compressor .................................................................................................................... ✔ ✔ ✔ ✔• Comfort-R™ mode approved ............................................................................................................ ✔ ✔ ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof ........................................................................ ✔ ✔ ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ................ ✔ ✔ ✔ ✔• Spine Fin™ coil ................................................................................................................................. ✔ ✔ ✔ ✔ • Compressor sump heat - factory installed ......................................................................................... ✔ — 3½-4 —• Factory supplied charge .................................................................................................................... R-410A R-410A R-410A R-410A• Glossy corrosion resistant finish ........................................................................................................ ✔ ✔ ✔ ✔• High pressure switch .......................................................................................................................... ✔ ✔ ✔ ✔• Low pressure switch ........................................................................................................................... ✔ ✔ ✔ ✔• Internal high / low pressure & temperature protection ....................................................................... — ✔ ✔ ✔• Liquid line filter drier - factory supplied or installed ............................................................................ ✔ ✔ ✔ ✔• Tarpaulin gray cabinet ........................................................................................................................ ✔ ✔ ✔ ✔• 10-year registered limited warranty on compressor, outdoor coil & all other functional parts (Residential Use)1 .......................................................................... ✔ ✔ ✔ ✔• Extended warranties available ....................................................................................................... ✔ ✔ ✔ ✔
Table SH-8-B — Optional AccessoriesModel Number Description Shipping Weight
Comfort Controls — See Comfort Controls/Zone Sensors Section1 Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at trane.com or by phone at 800-554-6413;
otherwise Trane Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on Comfortsite.com.2 Do not use with programmable thermostats.3 Activated on Power Off.4 Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information.
Sp
lit S
yste
m H
eat
Pu
mp
s
SH-9
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Effective 1/1/1722-8301-30
Split System Heat Pumps Three Phase
Table SH-9-A — 4TWA7 R-410A Split System Single Stage Heat Pump — Three Phase Nom. Cap. Uncrated Shipping Line Size (in)
Model Power Cooling Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) H W D (lbs.) Rating MCA* Fuse* Gas Liq.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with AHRI Standard 270-2008.
XR14(Single Stage)
3-Phase
XR17(Two Stage)
3-Phase
Sp
lit System
Heat P
um
ps
SH-10
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Effective 1/1/1722-8301-30
Split System Heat Pumps Three Phase
XR17 XR14Table SH-10-A — Features (4TWA7) (4TWA4)• SEER up to .......................................................................................................................................................................... 17.5 15.5• HSPF up to ........................................................................................................................................................................... 9.60 9.50• Comfort-R™ mode approved .............................................................................................................................................. ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof .......................................................................................................... ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................................. ✔ ✔• Spine Fin™ coil ................................................................................................................................................................... ✔ ✔• Compressor sump heat - factory installed ........................................................................................................................... ✔ ✔• Refrigerant ........................................................................................................................................................................... R-410A R-410A• Glossy corrosion resistant finish .......................................................................................................................................... ✔ ✔• High pressure switch ............................................................................................................................................................ ✔ ✔• Low pressure switch ............................................................................................................................................................. ✔ ✔• Liquid line filter drier - factory supplied ................................................................................................................................ ✔ ✔• Start kit - factory installed ..................................................................................................................................................... 2½ ✔• 5-year basic limited warranty on compressor, 1-year on outdoor coil & all other functional parts (Commercial Use) ................................................................................................................... — ✔• 5-year registered limited warranty on compressor, outdoor coil & 5-year on all other functional parts (Residential Use) ..................................................................................................................... — ✔• Extended warranties available .......................................................................................................................................... ✔ ✔
Table SH-10-B — Optional AccessoriesModel Number Description Shipping Weight
Comfort Controls — See Comfort Controls/Zone Sensors Section1 Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at trane.com or by phone at 800-554-6413;
otherwise Trane Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on Comfortsite.com.2 Do not use with programmable thermostats.3 Activated on Power Off.4 Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information.