The body of all Spectra-System implants are tapered evenly down from the top to facilitate insertion in an undersized socket (stop at intermediate drill) for expansion in soft bone.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ScrewIndirect®Screw-Receiving
Spectra-SystemSpectra-System®®CatalogCatalog
ScrewPlant®
ScrewPlus®Internal Hex
ScrewPlant®Internal Hex
ScrewRedirect®Angled Contoured
ScrewDirect®Straight Snap-on
One- and Two-Piece Implants
Bone Level 2-Stage
Tissue Level 1-Stage
GoDirect™OverDenture
Surgical Tray
4-5 ScrewPlant Implants
Table of Contents
1
2
3
6-7
8-9
10-11
16-17
14-15
22
23-25
26-28
32-33
Page #
Product Labeling:Definitions & Descriptions
ScrewPlus Implants
ScrewRedirect Implants
ScrewIndirect Implants& Components
Components for Screw-Receiving,Ball & GPS™ Abutments
The body of all Spectra-System implants are tapered evenly down from the top to facilitate insertion in an undersized socket (stopat intermediate drill) for expansion in soft bone. This increases initial stability (G. Niznick: Clinical Oral Health 2000 “Achieving Successin Soft Bone”). The SBM textured surface extends over the entire endosseous portion of the Spectra-System implants. Mini-threadsstart 1mm below the crest of the bone and extend for 2-2.5mm before transitioning into double-lead threads to the apex of theimplant. The mini-threads are half the depth and half the distance between adjacent peaks compared to the double-lead threadsthat extend to the apex of the implant. Mini-threads reduce stress in the critical crestal bone region while double-lead threads reduce the number of turns required to seat the implant. Vertical cutting grooves extend halfway up the implant from the apex forself-tapping insertion.
1.2mm 0.3mm
0.6mm
Mini-threads with Double-lead Threads for Faster Insertion
Implant Design & Surface
1.2mm
SBM surface is created by using a Soluble Blast Media of Hydroxylapatite (HA) crystals to create a medium-rough texture. We usethe same vendor for our SBM and HA coated surface treatments as was used by Paragon Implant Company from 1992-2000 when these studies were conducted.
Animal Studies Bone Response to SBM SurfaceSEMs of SurfacesMini-threads textured by blasting with SBM™: Blasted with Soluble HA ParticlesHA Coating: High Crystalline 40u layer
1) Our products carry the CE mark and fulfill the requirementsof the Medical Device Directive 93/42/EEC
2) Manufacturer Symbol3) Product code or reference number4) Product description5) Use before expiration date (XXXX-XX)6) Gamma sterilization symbol7) Single-use only symbol8) Caution: US law restricts the sale of these devices
by or on the order of a dentist or physician9) Tamper proof symbol
10) Refer to Instructions For Use (IFU)11) Lot number (XXXXXXXXXX)12) Implant body diameter color reference on surgical tray13) Implant prosthetic platform diameter (written and color-coded)14) Non-sterile symbol
3
1
4
5
6
7 11
12
13
8 10
10 = ScrewPlant SBM37 = 3.7mmD body diameter13 = 13mmL body length
• Internal connection with 2mm long hex & external bevel • Color-coded fixture-mount usable as a transfer & shortened for use as a straight abutment with snap-on comfort cap• 2mm extender retained by cover screw for use as a healing collar or for one-stage surgery• Surface options: SBM (Soluble Blast Media) or HA-coated• Tapered body allows insertion using Zimmer Dental’s Tapered Screw-Vent® drills
3.7mmDPlatform
5.7mmDPlatform
4.7mmDPlatform
Cover Screw
3.7mmDImplant
4.7mmDImplant
5.7mmDImplant
Extender
Carrier/Transfer
step 1 step 2 step 3 step 4
Fixture-Mount Transfer: Shortened for final abutment with Snap-On Comfort Cap and Transfer
ScrewPlant: Two-Piece Implant for Two-Stage SurgeryScrewPlant
SBM and HA Surface Implants Includes Cover Screw, Fixture Mount,Extender & Comfort Cap
103708 103710 103713 103716
104708 104710 104713 104716
105708 105710 105713 105716
103711113708 113710 113713 113716113711
105711
104711114708 114710 114713 114716114711
115708 115710 115713 115716115711
5
6
ScrewPlus One-Stage Implant System featuring:
3.7mmDPlatform
5.7mmDPlatform
4.7mmDPlatform
6.5mmDPlatform
• Internal connection with 2mm long hex & external bevel • Color-coded fixture-mount usable as a transfer & shortened for use as a straight abutment with snap-on comfort cap• 2mm extender retained by cover screw for use as a healing collar • Surface options: SBM (Soluble Blast Media) or HA-coated • Tapered body allows insertion using Zimmer Dental’s Tapered Screw-Vent® drills
3.7mmDImplant
4.7mmDImplant
3.7mmDImplant
5.7mmDImplant
Extender
step 1 step 2 step 3 step 4
Fixture-Mount Transfer: Shortened for final abutment with Snap-on Comfort Cap and Transfer
ScrewPlus: Two-Piece Implant for One-Stage Surgery
205708215708
205710215710
205713215713
205716215716
205711215711
ScrewPlus
SBM and HA Surface Implants
204708214708
204710214710
204713214713
204716214716
204711214711
Includes Cover Screw, Fixture Mount,Extender & Comfort Cap
8
4.7mmDPlatform
6.5mmDPlatform
5.7mmDPlatform
3.7mmDPlatform
3.7mmDImplant
5.7mmDImplant
4.7mmDImplant
Snap-OnComfort Cap
3.0mmDImplant
• Straight abutment head with retentive groove & beveled shoulder 1.5mm above crest of bone• Double-lead threads for 2X faster insertion & quadruple-lead threads near top• Color coded plastic fixture mount usable as a snap-on transfer• Snap-on plastic comfort cap usable as coping for temporary crown• Tapered body allows insertion using Zimmer Dental’s Tapered Screw-Vent® drills
• Screw-Receiving head with retentive groove & beveled shoulder 2.5mm above bone• Double-lead threads for faster insertion, with quadruple-lead mini-threads for reduced stress concentration near crest of bone• Color-coded plastic fixture mount usable as a snap-on transfer• Snap-on plastic comfort cap• Common prosthetic platform across all four diameters of implants• Includes 2mm implant extender• Tapered body allows insertion using Zimmer Dental’s Tapered Screw-Vent® drills
ScrewIndirect Implant Copings Includes Fixation Screw [1000-01]
405713
3.0mmDSBM Surface Implants Includes Carrier/Transfer (orange), Extender, Transfer &
Comfort Cap [Requires 2.5mmD Hex Tool]
403008 403010 403013 403016
ScrewIndirect: One-Piece Implant for One-Stage Surgery
ScrewIndi rect
Code Platform Description4000-13 5.0mmD Plastic Comfort Cap - 2ea4000-02 5.0mmD Plastic Implant Transfer - 2ea4000-62 5.0mmD Open-Tray Transfer plus Fixation Screw4000-63 5.0mmD Closed-Tray Transfer plus Fixation Screw4000-06 5.0mmD Aluminum Implant Analog1000-10 - Replacement Open-Tray Fixation Screw - 2ea1000-06 - Replacement Closed-Tray Fixation Screw - 2ea
Components for use with 2mmL ScrewIndirect Extender on pg 28
4000-62 4000-634000-02 4000-064000-13
Gold Titanium Plastic
4000-674000-654000-64 4000-66 4000-69
TitaniumGold/Plastic
403708 403710 403713 403716
ScrewIndirect Comfort Cap, Transfers & Analog
12
Snap-OnComfort Cap
GoDirect One-PieceImplant System Featuring:
• One-piece implant with GPS™ & Zest LOCATOR® compatible platform• Tapered, self-tapping body for increased stability in soft bone• 3.0mm narrow diameter implant with 1.8mm apical end allowing insertion with 2.3mmD drill• Double-lead threads for faster insertion plus quadruple-lead mini-threads for reduced stress concentration near crest of bone• Internal threads, capped off with cover screw allows for conversion to multi-unit abutment or fixed- detachable bars or bridges• All-in-1 Packaging includes snap-on transfer & comfort cap
Snap-On Comfort Cap and Transfer
Attach implant carrier as impression transfer
Attach housing for chairside pickup
Clinical Applications
Carrier/Transfer
Use plastic carrier to carry implant
Attach comfort cap to implant
3.7mmDImplant
4.7mmDImplant
3.0mmDImplant
Locator® is a registered trademark of Zest Anchors Company. The GoDirect™ and GPS™ Systems are neither authorized, endorsed nor sponsored by Zest Anchors Company
• 12° angled abutment head with contoured margins 1mm above crest of ridge• Single-lead threaded body is 0.3mm shorter than drill length to allow insertion of implant with desired direction of angled head• Double-lead mini-threads near top• Tapered body allows insertion using Zimmer Dental’s Tapered Screw-Vent® drills
ScrewRedirect PackagingScrewRedirect One-Piece Implant System featuring:
ScrewRedirect Implant Placement
Carrier
No interference if1mm clearance
Screw in using 2mm carrier/hex tool
Single lead threadsfor rotation control
Align angle & contour
Prepare as required Cement temporaryout of occlusion
3.7mmDImplant
4.7mmImplant
5.7mmDImplant
14
4.7mmDPlatform
5.7mmDPlatform
6.5mmDPlatform
ScrewRedirect
Code Description5037-07 Guide Pin for 3.7mmD Implant5047-07 Guide Pin for 4.7mmD Implant5057-07 Guide Pin for 57mmD Implant
12o angled head of Redirect implant requires minimumof 1mm clearance on either side of implant body toallow for free rotation during implant placement.
Compatible with Zimmer’s TaperedScrew-Vent® drills
503713 503716
504713 504716
505713 505716
ScrewRedirect: One-Piece Implant for One-Stage Surgery
ScrewRedirect
15
Use after 2.3mmD Pilot Drill as a guide to ensureclearance & correct implant positioning
Guide Pin
Includes Carrier [Requires 2.0mmD Hex Tool]
5037-07 5057-075047-07
16
The implant is mounted on a color-coded fixture-mount designed for use as a transfer & shortened for use as a straight abutment. A snap-on comfort cap is provided for the modified abutment. A cover screw is included in each vial. The ScrewPlant & ScrewPlus alsoinclude a 2mm extender retained by the cover screw for use as a healing collar.
ScrewPlant & ScrewPlus Fixture-Mount Packaging
Each cap is color-coded byplatform diameter of implant
All of Implant Direct’s implantscome in a sterile vial
Each label is color-coded withtwo tear-off labels
Drop implant assembly out ofvial onto a sterile surface
Remove implant assembly witha fixture-mount drill or ratchet
Remove the holder containingthe cover screw & comfort cap
Align the flat of the fixture-mountto the buccal
Snap-on comfort cap is locatedin the top portion of holder
Prepare surgical site with doublecutting drill
Insert implant into osteotomy Index fixture-mount flat to labial
Remove fixture-mount
Remove colored section from fixture-mount through groove creating afinal straight abutment
Attach fixture-mount to corresponding color-coded implant analog
Flat of hex indexedto buccal
To attach abutment, use 30Ncmin hard bone. In soft bone, useonly finger pressure
Check for occlusal clearanceprior to attaching comfort cap
Test retention & rotate ifnecessary to increase retention
Suture soft tissue aroundcomfort cap
17
During implantplacement, indexthe flat of thefixture-mount
Pour the working castin dental stone withsoft tissue replicationmaterial
Option 2 : Stage-One transfer followed by laboratory procedures for abutment preparation & provisionalization
Attach the angledabutment to the implant analog in theworking cast with a1.25mmD hex tool
Block out the top ofthe fixture-mount& make a transfer impression
Attach the coverscrew & submergeimplant
Attach the fixture-mount to the implantanalog & seat into thenegative of the impression
Remove the fixture-mount from the working cast with the1.25mmD hex tool
Make animpressionfollowingstandardclinicalprocedures
Mark therequiredmodificationsto achieveappropriateclearance
Finesse themargins witha high-speedbur &copious irrigationprior to finalimpressing
Attach the abutment to the correspondingimplant analog& reduce theabutmentto achieveappropriateclearance
Followstandard laboratory procedures to fabricatethe finalrestoration &cement ontothe preparedabutment
Fig. 2 The two-piece, 15º AngledAbutment consists of an angled
body and a Fixation Screw
Fig. 1Fixture Mount/Transfer
Detach the abutmentwith the1.25mmDhex tool
Clinical & Laboratory Procedures for Contoured Abutments
To establish the optimum angle of the abutment,index the flat surface of the Fixture-Mount/Transfereither toward or away from the desired direction ofabutment angle at the time of implant placement.
7. Seat denture over Titanium Temporary Copings to confirm passive placement.Mark copings to indicate required verticalreduction prior to luting to denture base.
1. Use a forceps to remove the comfort caps exposing the tops of the implants.
10a & b. Attach implant replicas to copings and tighten using 1.25mmD Hex Tool. Pour aworking cast using a soft tissue replication material if required due to anatomical undercuts.
6. Confirm markings on under surface ofdenture. Use acrylic trimmer to drill holesthrough denture corresponding to markedpositions.
3. Place the fixation screw through the coping & tighten using the 1.25mmD Hex Tool. Standard torque value for fixation screws is30Ncm.
12. Attach prosthesis to implants & tighten inplace using the appropriate tooling. Occludescrew access holes with material of choice.
2. Select the Titanium Temporary Coping matching the prosthetic platform. Titanium Coping [4000-69] is supplied with fixationscrews [1000-01] and [1000-05]. An optionallonger screw [1000-10] is also available.
11. Remove prosthesis from working cast and trim to allow access for patient cleaning. The prosthesis is now a fixed restoration, removable by clinician only.
5. Mark top of Titanium Temporary Copings withindelible marker. Place denture on top of copingsto transfer their position to under surface of denture.
4. Confirm there is less than 40 degrees of relative divergence between copings to besplinted together.
8. Occlude screw access hole with cottonpellet. Use autopolymerizing acrylic or similarlight cure material to attach prosthesis toTitanium Temporary Copings. Allow to set priorto removal from mouth.
9. Remove prosthesis from the mouth and flipover to expose tissue side. Use additionalautopolymerizing resin to fill in any voidsaround the processed copings.
ScrewIndirect Implant Prosthetic Technique
4000-69 1000-101000-01
18
1000-05
6a. Transfer Process: Place the Impression Coping [4500-02] onto the implant. Injectimpression material around the coping & recorda full-arch impression.
1. Use the black plastic component to carry theGoDirect implant to site. Initiate self-tapping ofimplant into osteotomy by rotating black carrier.Remove black plastic carrier once implant is stabilized.
8. Pull on the Black Processing Male at an angle& remove it from the metal cap. If needed,wedge a tool against the bottom inside of theblack plastic to aid in removal.
5b. Chairside Process: Mark location of components on under surface of prosthesis.Relieve the areas within the prosthesis so it canbe fully seated over the metal cap without interference. Process the cap into denture following standard procedures.
10. Insert the finished prosthesis. Instruct patient on standard cleaning instructions.
2. Use either the [GDT] or [GDIT for 4.7mmD] insertion tool or [GDD] insertion drill to rotatethe GoDirect implant into the osteotomy. Stabilize the assembly with downward fingerpressure.
05a. Chairside Process: Place the White Block-Out Spacer over the head of the implant. Attachthe metal cap with Black Processing Male fromProcessing Cap/Kit [1000-98S] or [1000-98SI].
9. Use the Male Seating Tool to firmly push theReplacement Male of choice into the emptymetal cap located within the denture.
4. Attach the Parallel Posts [1000-97] to the implants to determine the divergence If the relative divergence between two assemblies isless than 20° use the white, red, orange or greenGPS Male.
7. Place the white Block-Out Spacer over thehead of the Implant Analog. Attach the metalcap with Black Processing Male. Process the denture following standard procedures.
6b. Laboratory Procedure: Insert the ImplantAnalogs [4500-06] into the Impression Copings[4500-02]. The laboratory fabricates the workingcast.