Top Banner
Specifying Sustainable Design
43

Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Dec 14, 2015

Download

Documents

Darryl Beazley
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying Sustainable Design

Page 2: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

BSD SpecLink-E supports the following Green Building Rating Systems:• LEED v4 BD+C:– New Construction and Major Renovations– Core and Shell Development– Schools, Healthcare– Data Centers– Warehouses and Distribution Centers– Hospitality, Retail

Rating Systems Supported

Page 3: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Get Started Early

• Achieving a sustainable design certification will depend heavily on early design decisions, including site selection

• Waiting until the construction documents phase to begin making green decisions may make achieving certification difficult or impossible

Page 4: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Sustainable Design Criteria

• Designing for sustainability can’t be delegated to a Design-Bid-Build Contractor

• A Design-Builder can be given a target rating with as little or as much direction as desired

• BSD SpecLink-E includes sustainable design criteria in Section DC0 Facility Design Criteria, which can be used for both Design-Build projects and early design documentation on Design-Bid-Build projects

Page 5: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying StrategyTypes of Issues

•No matter which rating system is used, all issues fall into one of these categories:– Intrinsic to Location– Design Phase Activity– Post-Construction Activity– Embodied in Overall Design– Explicitly Shown In Contract Documents

Page 6: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying StrategyIntrinsic to Location

• The specification cannot address issues that are completely dependent on site location:– Avoidance of sensitive lands– Brownfield site– Surrounding density and diverse uses– Availability of alternative transportation

Page 7: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying Strategy Design Phase Activities

• The specification cannot address:– Project planning– Design process– Site environmental assessment– School campus master plan– Life cycle analysis of design

Page 8: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying StrategyPost-Construction Issues

• The specification cannot address:– Purchasing Green Power– Provisions for Recycling– Prohibition of Smoking– Operational Issues: cleaning, pest control– Joint use of facilities– Tenant guidelines

Page 9: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying StategyIssues Embodied in the Design

• No particular, immediately identifiable specification solution:– Parking capacity, reduced parking footprint– Design for water and energy conservation– Optimization of energy performance– Ventilation design– Design for flexibility

Page 10: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying StrategySolutions in Contract Documents

• For each issue, determine where it should be shown or specified:– Only shown on the drawings– Only indicated in the specifications– Partly shown and partly specified

• Now you know what needs to be included in the specifications

Page 11: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

– 01 5713 - Temporary Erosion & Sediment Control– 01 5721 - Indoor Air Quality Controls– 01 7000 - Execution and Closeout Requirements (site

drainage, pollution prevention)– 01 7419 - Construction Waste Management & Disposal– 02 6500 - Underground Storage Tank Removal– 02 8400 - Polychlorinate Biphenyl (PCB) Remediation– 31 1000 - Site Clearing (limits on site disturbance)

SpecLink-E ProvidesContractor Procedures

Page 12: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

– 01 9113 - General Commissioning Requirements

– 01 9114 - Commissioning Authority Responsibilities

– 23 0800 - Commissioning of HVAC

SpecLink-E ProvidesCommissioning Procedures

Page 13: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

– Explanation of project goals– What the Contractor is required and not required

to do to aid the certification process– A method for collecting information about “green

materials”– Procedures to be followed– List of sections where particular sustainable

design issues are specified

SpecLink-E Provides01 3329 - Sustainable Design Reporting:

Page 14: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

– 01 6000 - Product Requirements (definitions) – 01 6116 - VOC Content Restrictions

Forms for Submittals– 01 3329.04 – Material Content Form– 01 3329.07 – Prohibited Content Installer

Certification

SpecLink-E ProvidesSections related to “Green Materials”

Page 15: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

– 02 4100 – Demolition: Removal of existing pavements and other impervious surfacing; partial demolition for preserving existing construction

– 028400 – Polychlorinate Biphenyl (PCB) Remediation: Abatement of PCBs, mercury, & other substances regulated under U.S. Toxic Substances Control Act

SpecLink-E Provides02 Existing Conditions

Page 16: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

– 03 3000 – Cast-in-Place Concrete (and 4 other Division 3 sections): Option to replace some Portland cement with recycled content

05 Metals– 05 5000 – Metal Fabrications: Custom-

fabricated entrance mat frames– 05 5305 – Metal Gratings and Floor Plates:

Custom-fabrications entrance gratings

SpecLink-E Provides03 Concrete

Page 17: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

06 Wood, Plastics, and Composites– 06 1000 - Rough Carpentry (and 9 other Division 6

sections): Prohibition on old growth timber, sustainably harvested wood, salvaged and re-used wood

07 Thermal and Moisture Protection• Vegetated roof solutions:– 07 1300 - Sheet Waterproofing– 07 1400 - Fluid-Applied Waterproofing– 07 5050 - Vegetated Roof Components

SpecLink-E Provides

Page 18: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

07 Thermal and Moisture Protection• Rain water collection surfaces:– 07 4113 – Metal Roof Panels– 07 6100 – Sheet Metal Roofing

• White or light colored roof membrane:– 07 5300 – Elastomeric Membrane Roofing: – 07 5400 – Thermoplastic Membrane Roofing:

• Emissions-compliant sealants:– 078400 - Firestopping– 07 9005 - Joint Sealers: Plus sealing

between residential units if not firestopped

SpecLink-E Provides

Page 19: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

SpecLink-E Provides08 Openings– Many sections for daylighting and views

09 Finishes– 09 2116 – Gypsum Board Assemblies: Deck-to-

deck sealed partitions around rooms where hazardous gases or chemicals are used

– 09 6800 – Carpeting: GreenLabel Plus certified

– 09 6850 - Carpet Tile: GreenLabel Plus certified

– 09 9000 - Painting and Coating: VOC limits

Page 20: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

SpecLink-E Provides10 Specialties– 10 5100 – Lockers: For bicycle entrance– 10 7113.43 – Fixed Sun Screens

11 Equipment– 11 3100 – Residential Appliances: Energy Star

rated appliances– 11 8277 – Waste Compactors: For recycling

Page 21: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

SpecLink-E Provides12 Furnishings– 12 2400 – Window Shades: Motorized shades– 12 4813 – Entrance Floor Mats and Frames:

Manufactured grilles and gratings for high volume entryways

– 12 9313 – Bicycle Racks– 12 9314 – Bicycle Lockers

14 Conveying Equipment– 14 9100 – Facility Chutes: For recycling

Page 22: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

SpecLink-E Provides21 Fire Suppression– 21 2200 – Clean Agent Fire Extinguishing

System: Non-Halon extinguishing agent

22 Plumbing– 22 0519 – Meters and Gages for Plumbing

Piping: For metering subsystems– 22 1005 – Plumbing Piping: Documentation of

regulatory lead-content restrictions; certification of proper soldering of copper piping

Page 23: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

SpecLink-E Provides22 Plumbing (cont.)– 22 3000 – Plumbing Equipment: Pumps for

potable and non-potable water– 22 4000 – Plumbing Fixtures: WaterSense-

labeled fixtures; documentation of regulatory lead-content restrictions; high-efficiency and dry toilet fixtures

– 22 4300 – Healthcare Plumbing Fixtures: WaterSense-labeled fixtures; documentation of regulatory lead-content restrictions

Page 24: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

SpecLink-E Provides23 HVAC

– 23 0800 - Commissioning of HVAC– 23 0130.51 – HVAC Air Duct Cleaning– 23 0913 – Instrumentation and Control

Devices for HVAC– 23 0923 – Direct-Digital Control System for

HVAC– 23 2113.33 - Ground-Loop Heat-Pump Piping– 23 2500 – HVAC Water Treatment: To reduce

cooling tower water usage

Page 25: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

SpecLink-E Provides23 HVAC (cont.)

– 23 3100 – HVAC Ducts and Casings: Emissions-compliant duct sealers

– 23 4000 – HVAC Air Cleaning Devices: MERV-compliant air filters

– 23 5216 – Condensing Boilers– 23 6xxx – Chiller and Refrigeration Equipment

sections: Low-GWP refrigerant

– 23 8149 – Water-to-Water Heat Pumps

Page 26: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

SpecLink-E Provides26 Electrical

– 26 0501 – Minor Electrical Demolition: Removal of abandoned cables containing lead; minor removal of mercury-containing lamps and PCB- and DEHP-containing ballasts

– 26 0519 – Low-Voltage Electrical Power Conductors and Cables: Limitations on lead content of cable insulation

– 26 0923 – Lighting Control Devices – 26 0943 – Network Lighting Controls: Integrated

lighting and window shade controls

– 26 2726 – Wiring Devices: Manual lighting controls.

Page 27: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

SpecLink-E Provides26 Electrical (cont.)

– 26 2726 – Wiring Devices: Manual lighting controls

– 26 3100 – Photovoltaic Collectors: With related equipment and supports

– 26 5100 – Interior Lighting: Limitations on mercury-content of lamps; minimum lamp life

– 26 5600 – Exterior Lighting: Limitations on mercury-content of lamps; minimum lamp life; fixtures selected to reduce light pollution

Page 28: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

31 Earthwork– 31 1000 - Site Clearing: Vegetation protection; site

clearing waste management– 31 2200 – Grading: For restoring site water flows– 31 3700 – Rip Rap: For erosion protection

32 Exterior Improvements– 32 0190 – Operation and Maintenance of Planting: First

year maintenance– 32 1125 - Turf Surfaced Roadways– 32 1413 - Precast Concrete Unit Paving: Open-grid pavers

SpecLink-E Provides

Page 29: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Step-by-Step01 3329 – Sustainable Design Reporting

– Select and open the section

– Choose the Rating System

– Review the automatically activated text, X-out if not relevant to your project

– Review inactive text, select if relevant

– In PART 3, select all sections having solutions relevant to your project

Project Tree– Green status box indicates sections activated

– Review each section for further decisions

Page 30: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Section 01 3329

First select Section 01 3329 in the folder tree, open it and check the status box at the title.

Page 31: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Section 01 3329

Next, activate the relevant Rating System and click on the blue text to see further choices

Page 32: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Section 01 3329

Each section selected, and each option below it, automatically turns on the relevant section and text elsewhere in the spec.

The PART 3 checklist may have some items already highlighted in green. Activate their parent heading to activate them.

Page 33: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Section 01 3329

The final section covers scope and procedures

and a list of all the other sections with an indication of what the requirements are.

Page 34: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Step-by-StepSubmittal Report– Automatic report lists all sections in project that require

sustainable design documentation submittals– Properly tagged user-added submittals also show

Page 35: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying for LEED

As of May 2014, BSD SpecLink-E supports the following LEED Rating Systems:

LEED v4 BD+C:– New Construction and Major Renovations– Core and Shell Development– Schools, Healthcare– Data Centers– Warehouses and Distribution Centers– Hospitality, Retail

Page 36: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying for LEED

Review the rating system document to classify prerequisites and credits into categories–Intrinsic to Location–Design Phase Activity–Post-Construction Activity–Embodied in Overall Design–Shown on the Drawings–To Be Specified

Page 37: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying for LEED

Identify the Goal –Certified: 40 points–Silver: 50 points–Gold: 60 points–Platinum: 80 points–Plus regional priority credits possible

And the Facility Type –New Construction, Schools, Healthcare, etc.

Page 38: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying for LEED

Decide whether to pursue:–Building Material Disclosure Credits–Building Material Optimization Credits–Low-Emitting Materials Credits

• Make appropriate selections in 01 3329

• If pursuing any of them, include:–Section 01 3329.04 – Material Content Form

Page 39: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying for LEED

Disclosures, like EPDs

The Material Content Form is automatically tailored to the types of credits being pursued

Content types, such as recycled, certified wood, VOCs

Cost information, for performing the calculations

Page 40: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying for LEED

Low-Emitting Materials Credits:•Very possible to write an impossible spec

– The thresholds are very high (90-100%)– The indoor-emissions test is relatively new– But this credit is divided into 5 categories of

products that can be pursued separately as long as at least 2 categories are achieved (3 for Schools, Healthcare)

•Edit Section 01 6116 – VOC Content Restrictions, to suit your decisions

Page 41: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Specifying for LEEDIf desired, use the Prohibited Content Installer Certification form reduce the likelihood that installers ignore the low-emitting material specifications

Assertions that they did not use any products with prohibited content, whether specified or not

Certification signature

Instructions

Page 42: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Coming Soon

In the coming months, the following additional rating systems will be added:

– LEED v4 ID+C: Interiors Design & Construction– LEED v4 Homes– GreenGlobes for New Construction– Federal Guiding Principles for New Construction

and Major Renovations– LEED v4 ND: Neighborhood Development (with

construction)

Page 43: Specifying Sustainable Design. BSD SpecLink-E supports the following Green Building Rating Systems: LEED v4 BD+C: –New Construction and Major Renovations.

Thank you for your interest!

Specifying Sustainable Designwith BSD SpecLink-E

Questions?Building Systems Design, Inc.

www.bsdsoftlink.com888-BSD-SOFT(888 273-7638)