RUNNING CURRENT (HEATING)RATED POWER INPUT (COOLING)RATED POWER INPUT (HEATING)PROTECTION DEVICE
HEIGHT (H)
TYPE
COMPRESSOR
HEAT EXCHANGE
DIMENSION
CASING
in
mm/inmm/in
mm/in
mm/in
mm/inmm/inmm/inmm/inmm/in
ROTARY
ELECTRO GALVANIZED MILD STEEL1.0/0.039
FLARE VALVE
TUBE IN TUBE (COAXIAL COIL)
WATER PIPE SIZEkPa
m3/in
AµF
V/Ph/Hz
A
WW
4.4
906
5.55.3
1180
4.3
916
6.16.8
1370
15201100
25 30 50
OVERLOAD PROTECTION & HIGH PRESSURE SWITCH
0.758.12
1.250.9510.35 14.54
1/2" BSPT FEMALE
700/30.1
6.35/1/415.88/5/8
400/15.8813/32.0
15.88/5/8
390/15.4
EPOXY POLYESTER POWDER COATING
12.7/1/2
360/14.2
350/13.8320/12.6
POWER SOURCE 220-240/1/50
SOUND PRESSURE LEVEL 4245.3
3931.7
40
280/11.035.9
R410A/CAPILLARY TUBE0.9250.700 0.725
REFRIGERANT/CONTROLkg
NOTES:1) NOMINAL COOLING AND HEATING CAPACITIES ARE BASED ON THE FOLLOWING CONDITIONS: a) COOLING: INDOOR 27.0˚C DB/19.0˚C WB; ENTERING WATER TEMPERATURE 30.0ºC, LEAVING WATER TEMPERATURE 35.0ºC b) HEATING: INDOOR 20.0˚C DB/15.0˚C WB; ENTERING WATER TEMPERATURE 20.0ºC2) EFFECTIVE POWER INPUT IS USED IN THE RATED EER/COP CALCULATION, ACCORDING TO ISO 5151 & ISO 132533) ALL SPECIFICATION ARE SUBJECT TO CHANGE BY MANUFACTURER WITHOUT PRIOR NOTICE4) AIR FILTER IS AN OPTIONAL ITEM
S P E C I F I C AT I O N S
M5WSS helps you to design an energy efficient green building or retrofitting an existing building to lower the operating costs.
Quiet & Reliable• Quiet & highly reliable Matsushita rotary compressor• Isolate compressor legs with rubber grommets to prevent vibration• Rigid cabinet construction for maximum durability & minimum vibration
Easy Installation & Low Cost Design• Compact, low profile cabinet sizes make it easy to install• Brass adaptor allows easy water pipe connection
High Efficiency, Low Operating Costs• High EER - Coaxial heat exchanger is designed for maximum heat transfer with minimum pressure drop - High efficiency compressor (Matsushita) reduces energy consumption
Easy, Low Cost Maintenance• Removable access panels for easy servicing & maintenance• Two refrigerant service valves (High & Low Side) for easy servicing
Environmental Friendly• R410A refrigerant is a non-ozone depleting HFC refrigerant
NOTES:1) NOMINAL COOLING AND HEATING CAPACITIES ARE BASED ON THE FOLLOWING CONDITIONS: a) COOLING: INDOOR 27.0˚C DB/19.0˚C WB; ENTERING WATER TEMPERATURE 30.0ºC, LEAVING WATER TEMPERATURE 35.0ºC b) HEATING: INDOOR 20.0˚C DB/15.0˚C WB; ENTERING WATER TEMPERATURE 20.0ºC2) EFFECTIVE POWER INPUT IS USED IN THE RATED EER/COP CALCULATION, ACCORDING TO ISO 5151 & ISO 132533) ALL SPECIFICATION ARE SUBJECT TO CHANGE BY MANUFACTURER WITHOUT PRIOR NOTICE4) AIR FILTER IS AN OPTIONAL ITEM
MODEL
INDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
POWER SOURCE
EXTERNAL STATIC PRESSURE (H/M/L)FAN MOTOR
MATERIALDIAMETER
THICKNESSROWFIN PER INCH
HEIGHT (H)WIDTH (W)
OPERATION
HEIGHT (H)WIDTH (W)DEPTH (D)
DEPTH (D)
ROOM TEMPERATURE
WEIGHT
CONTROL
CONDENSATE DRAIN SIZEAIR FILTER
PACKINGDIMENSION
SOUND PRESSURE LEVEL (H/M/L)
RATED POWER INPUTEFFECTIVE POWER UNITRATED RUNNING CURRENT
MATERIAL
TUBE
FIN
FAN
COIL
DIMENSION
mm/in
mm/in
mm/inmm/inmm/in
kg
kg
dBA
dBA
mm/in
mm/inmm/inmm/in
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
EFFECTIVE TOTAL POWER (COOLING)EFFECTIVE TOTAL POWER (HEATING)NOMINAL TOTAL POWER (COOLING)NOMINAL TOTAL POWER (HEATING)NOMINAL TOTAL CURRENT (COOLING)NOMINAL TOTAL CURRENT (HEATING)
FACE AREA 0.115/1.238 0.115/1.238 0.143/1.542 0.176/1.892 0.176/1.892261/10.3 261/10.3261/10.3261/10.3261/10.3765/30.1 765/30.1 905/35.6 1065/41.9 1065/41.9
m2/ft2
COMPRESSOR TYPECAPACITOR
WATER FLOW RATEWATER PRESSURE DROP
WIDTH (W)DEPTH (D)
WEIGHT
REFRIGERANT CHARGEMATERIALTHICKNESSFINISHINGTYPE
SIZE LIQUIDPIPE
PACKINGDIMENSION
GASHEIGHT (H)WIDTH (W)DEPTH (D)
RUNNING CURRENT (COOLING)RUNNING CURRENT (HEATING)RATED POWER INPUT (COOLING)RATED POWER INPUT (HEATING)PROTECTION DEVICE
HEIGHT (H)
TYPE
COMPRESSOR
HEAT EXCHANGE
DIMENSION
CASING
in
mm/inmm/in
mm/in
mm/in
mm/inmm/inmm/inmm/inmm/in
ROTARY
ELECTRO GALVANIZED MILD STEEL1.0/0.039
FLARE VALVE
TUBE IN TUBE (COAXIAL COIL)
WATER PIPE SIZEkPa
m3/in
AµF
V/Ph/Hz
AWW
2.32.3502512
2.8
662
4.44.3916
2.9642
5.55.3
11801100906
6.120 30 25 30 50
6.813701520
OVERLOAD PROTECTION & HIGH PRESSURE SWITCH
0.455.36
0.515.88
0.950.75 1.2514.548.12 10.35
1/2" BSPT FEMALE
700/30.1
6.35/1/49.52/3/8 12.7/1/2 15.88/5/8330/11.8
400/15.8813/32.0
15.88/5/8390/15.4
EPOXY POLYESTER POWDER COATING
9.52/3/8360/14.2
290/11.4 350/13.8320/12.6
POWER SOURCE 220-240/1/50
SOUND PRESSURE LEVEL 3629
4036
3731
4245
39
280/11.032
R410A/CAPILLARY TUBE0.600 0.7250.600 0.9250.700
REFRIGERANT/CONTROLkg
S P E C I F I C AT I O N S
FEATURES
14
13
12
11
10
9
8
7
6
5
4
32
1
Cooling Tower/Boiler
1. Durable Painted Galvanised Steel2. Insulated Cabinet Panels3. 4 Way Valve4. Hanger Bracket5. Removable Access Panel For Easy Servicing & Maintenance6. High Efficiency Coaxial Heat Exchanger (Tube In Tube)7. Insulated Cap. Tube8. Water Temperature Sensor9. Flare Valve For Gas Pipes Connection10. Drain Pipe Connection11. Brass Adaptor For Water Pipe Connection12. Control Box13. High Efficiency Compressor With Rubber Isolators14. High Pressure Switch