Top Banner
PHONE 319-363-0237 TOLL-FREE 800-553-8861 TOLL-FREE FAX 866-252-6694 FAX 319-363-3867 0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 1 Always check the owners manual you received with your purchase. The manual will have the most current specifications that might have changed since this catalog was printed. SPECIFICATIONS: 110 VACUUMS 2 SPECIFICATIONS: 220 VACUUMS 3 SPECIFICATIONS: AIR/VACS 4 SPECIFICATIONS: AIR/WATER/VACS 5 INSTALLATION: VACUUMS 6 SPECIFICATIONS: VAC SCENT 9 INSTALLATION: VAC SCENT 10 SPECIFICATIONS: VAC SHAMPOO & SPOT REMOVER 13 INSTALLATION: VAC SHAMPOO 13 INSTALLATION: 28000 AND 20000 15 INSTALLATION: 11000 & 12000 17 SPECIFICATIONS: 11000 & 12000 17 INSTALLATION: SCENT MACHINE 20 SPECIFICATIONS: AIR MACHINES & AIR/WATER MACHINES 21 INSTALLATION: AIR AND AIR/WATER MACHINES 21 SPECIFICATIONS AND INSTALLATION INFORMATION
21

SPECIFICATIONS AND INSTALLATION INFORMATION

May 20, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 1

Always check the owners manual you received with your purchase. The manual will have the most currentspecifications that might have changed since this catalog was printed.

SPECIFICATIONS: 110 VACUUMS 2

SPECIFICATIONS: 220 VACUUMS 3

SPECIFICATIONS: AIR/VACS 4

SPECIFICATIONS: AIR/WATER/VACS 5

INSTALLATION: VACUUMS 6

SPECIFICATIONS: VAC SCENT 9

INSTALLATION: VAC SCENT 10

SPECIFICATIONS: VAC SHAMPOO & SPOT REMOVER 13

INSTALLATION: VAC SHAMPOO 13

INSTALLATION: 28000 AND 20000 15

INSTALLATION: 11000 & 12000 17

SPECIFICATIONS: 11000 & 12000 17

INSTALLATION: SCENT MACHINE 20

SPECIFICATIONS: AIR MACHINES & AIR/WATER MACHINES 21

INSTALLATION: AIR AND AIR/WATER MACHINES 21

SPECIFICATIONS AND INSTALLATION INFORMATION

Page 2: SPECIFICATIONS AND INSTALLATION INFORMATION

J.E. ADAMS INDUSTRIES, LTD ■ WE WORK HARDER TO PROVIDE YOU SOLUTIONS ■ WWW.JEADAMS.COM

2 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 0405

SPECIFICATIONS: 110 VACUUMS

SINGLE DOOR VACUUMSHEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER (depending on model): 20” or 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 150 LBS.VACUUM:

110 VOLTS, 16 AMPS188 CFM, 2 FILTER BAGS (8072)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORY, PRGY2(E47185)CSA CERTIFIED, CLASS 1611 01(LR31393)

COMMERCIAL SINGLE DOOR VACUUMSHEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER (depending on model): 20” or 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 26”

WEIGHT: 122 LBS.VACUUM:

110 VOLTS, 16 AMPS188 CFM, 2 FILTER BAGS (8072)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORY, PRGY2(E47185)CSA CERTIFIED, CLASS 1611 01(LR31393)

OVAL VACUUMSHEIGHT: 61”CANISTER DIAMETER: 15.98” x 26.28”DOME DIAMETER: 19.9” x 30”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 35”

WEIGHT: 219 LBS.VACUUM:

110 VOLTS, 16 AMPS188 CFM, 4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORY, PRGY2(E47185)CSA CERTIFIED, CLASS 1611 01(LR31393)

2 DOOR VACUUMSHEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER (depending on model): 20” or 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 155 LBS.VACUUM:

110 VOLTS, 16 AMPS, 188 CFM, 4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORY, PRGY2(E47185)CSA CERTIFIED, CLASS 1611 01(LR31393)

COMMERCIAL 2 DOOR VACUUMSHEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER (depending on model): 20” or 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 140 LBS.VACUUM:

110 VOLTS, 16 AMPS, 188 CFM4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORY, PRGY2(E47185)CSA CERTIFIED, CLASS 1611 01(LR31393)

DUAL VACUUMSHEIGHT: 59”CANISTER DIAMETER: 15.6” x 26.12”DOME DIAMETER: 19.9” x 30”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 37”

WEIGHT: 238 LBS.VACUUM:

110 VOLTS, 16 AMPS, 188 CFM4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORY, PRGY2(E47185)CSA CERTIFIED, CLASS 1611 01(LR31393)

Page 3: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 3

SPECIFICATIONS: 220 VACUUMS

SINGLE DOOR VACUUMSHEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER (depending on model): 20” or 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 150 LBS.VACUUM:

220 VOLTS, 8 AMPS, 60 HZ188 CFM2 FILTER BAGS (8072)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGE

COMMERCIAL SINGLE DOOR VACUUMSHEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER (depending on model): 20” or 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 122 LBS.VACUUM:

220 VOLTS, 8 AMPS, 60 HZ188 CFM2 FILTER BAGS (8072)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGE

OVAL VACUUMSHEIGHT: 61”CANISTER DIAMETER: 15.98” x 26.28”DOME DIAMETER: 19.9” x 30”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 35”

WEIGHT: 219 LBS.VACUUM:

220 VOLTS, 8 AMPS, 60 HZ188 CFM4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGE

2 DOOR VACUUMSHEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER (depending on model): 20” or 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 155 LBS.VACUUM:

220 VOLTS, 8 AMPS, 60 HZ188 CFM4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGE

COMMERCIAL 2 DOOR VACUUMSHEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER (depending on model): 20” or 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 140 LBS.VACUUM:

220 VOLTS, 8 AMPS, 60 HZ188 CFM4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGE

DUAL VACUUMSHEIGHT: 59”CANISTER DIAMETER: 15.60” x 26.12”DOME DIAMETER: 19.9” x 30”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 37”

WEIGHT: 238 LBS.VACUUM:

220 VOLTS, 8 AMPS, 60 HZ188 CFM4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGE

Page 4: SPECIFICATIONS AND INSTALLATION INFORMATION

J.E. ADAMS INDUSTRIES, LTD ■ WE WORK HARDER TO PROVIDE YOU SOLUTIONS ■ WWW.JEADAMS.COM

4 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 0405

SPECIFICATIONS: AIR/VACS

SINGLE DOOR AIR/VACUUMS8610 SERIES, WITH AND WITHOUT HOSE REEL

HEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER: 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 225 LBS.VACUUM:

110 VOLT, 16 AMPS188 CFM2 FILTER BAGS (8072)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORYPRGY2 (E47185)CSA CERTIFIED, CLASS 1611 01 (LR31393)

AIR:110 VOLT, 14 AMPS60 HZ1.5 HORSEPOWERONE CYLINDERONE STAGEOIL-LESS

SCFM @ PSI:6 @ 05 @ 204.1 @ 403.1 @ 902.9 @ 1002.1 @ 125 (MAX PSI)

TEMPERATURE RANGE: -10 DEGREES F TO 100 DEGREES F.

MOTOR:1.5 HP, 1725 RPM, CAPACITOR START,NEMA 56 FRAME, AUTOMATIC THERMALOVERLOAD.

2 DOOR AIR/VACUUMS9420 SERIES, WITH AND WITHOUT HOSE REEL

HEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER: 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 230 LBS.VACUUM:

110 VOLT, 16 AMPS188 CFM4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORYPRGY2 (E47185)CSA CERTIFIED, CLASS 1611 01 (LR31393)

AIR:110 VOLT, 14 AMPS60 HZ1.5 HORSEPOWERONE CYLINDERONE STAGEOIL-LESS

SCFM @ PSI:6 @ 05 @ 204.1 @ 403.1 @ 902.9 @ 1002.1 @ 125 (MAX PSI)

TEMPERATURE RANGE: -10 DEGREES F TO 100 DEGREES F.

MOTOR:1.5 HP, 1725 RPM, CAPACITOR START,NEMA 56 FRAME, AUTOMATIC THERMALOVERLOAD.

Page 5: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 5

SPECIFICATIONS: AIR/WATER/VACS

SINGLE DOOR AIR/WATER/VACUUMS8648T, 8648, 8648VRT, 8648VT

HEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER: 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 180 LBS.VACUUM:

110 VOLT, 16 AMPS188 CFM2 FILTER BAGS (8072)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORYPRGY2 (E47185)CSA CERTIFIED, CLASS 1611 01 (LR31393)

AIR:110 VOLT, 14 AMPS60 HZ1.5 HORSEPOWERONE CYLINDERONE STAGEOIL-LESS

SCFM @ PSI:6 @ 05 @ 204.1 @ 403.1 @ 902.9 @ 1002.1 @ 125 (MAX PSI)

TEMPERATURE RANGE: -10 DEGREES F TO 100 DEGREES F.

MOTOR:1.5 HP, 1725 RPM, CAPACITOR START,NEMA 56 FRAME, AUTOMATIC THERMALOVERLOAD.

2 DOOR AIR/WATER/VACUUMS8648TH, 8648H

HEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER: 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 240 LBS.VACUUM:

110 VOLT, 16 AMPS188 CFM4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORYPRGY2 (E47185)CSA CERTIFIED, CLASS 1611 01 (LR31393)

AIR:110 VOLT, 14 AMPS60 HZ1.5 HORSEPOWERONE CYLINDERONE STAGEOIL-LESS

SCFM @ PSI:6 @ 05 @ 204.1 @ 403.1 @ 902.9 @ 1002.1 @ 125 (MAX PSI)

TEMPERATURE RANGE: -10 DEGREES F TO 100 DEGREES F.

MOTOR:1.5 HP, 1725 RPM, CAPACITOR START,NEMA 56 FRAME, AUTOMATIC THERMALOVERLOAD.

Page 6: SPECIFICATIONS AND INSTALLATION INFORMATION

J.E. ADAMS INDUSTRIES, LTD ■ WE WORK HARDER TO PROVIDE YOU SOLUTIONS ■ WWW.JEADAMS.COM

6 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 0405

VACUUM INSTALLATION - 1 OF 3

Page 7: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 7

VACUUM INSTALLATION - 2 OF 3

Page 8: SPECIFICATIONS AND INSTALLATION INFORMATION

J.E. ADAMS INDUSTRIES, LTD ■ WE WORK HARDER TO PROVIDE YOU SOLUTIONS ■ WWW.JEADAMS.COM

8 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 0405

VACUUM INSTALLATION - 3 OF 3

Page 9: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 9

SPECIFICATIONS: VAC SCENT

110 SPECIFICATIONS: VAC SCENT8900-110V, 8900-110

HEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER: 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 192 LBS.VACUUM:

110 VOLTS, 16 AMPS188 CFM, 2 FILTER BAGS (8072)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORY, PRGY2(E47185)CSA CERTIFIED, CLASS 1611 01(LR31393)

COMPRESSOR:1/12 HP OIL-LESS COMPRESSOR DISPENSES 1 1/2 OZ. PER MINUTE

Page 10: SPECIFICATIONS AND INSTALLATION INFORMATION

J.E. ADAMS INDUSTRIES, LTD ■ WE WORK HARDER TO PROVIDE YOU SOLUTIONS ■ WWW.JEADAMS.COM

10 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 0405

VAC SCENT INSTALLATION - 1 OF 3

Page 11: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 11

VAC SCENT INSTALLATION - 2 OF 3

Page 12: SPECIFICATIONS AND INSTALLATION INFORMATION

J.E. ADAMS INDUSTRIES, LTD ■ WE WORK HARDER TO PROVIDE YOU SOLUTIONS ■ WWW.JEADAMS.COM

12 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 0405

VAC SCENT INSTALLATION - 3 OF 3

Page 13: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 13

SPECIFICATIONS: VAC SHAMPOO & SPOT REMOVER

VAC SHAMPOO & SPOT REMOVER9500

HEIGHT: 54-1/2”CANISTER DIAMETER: 19”DOME DIAMETER: 24”TOTAL DEPTH –

REAR OF DOME TOFRONT OF LOCK BOX: 29”

WEIGHT: 237 LBS.VACUUM:

110 VOLTS, 16 AMPS188 CFM, 4 FILTER BAGS (8076)

MOTORS:AMETEK UNIVERSAL TYPE, 50/60HZ17,500-22,500 RPM2 STAGE PERIPHERAL BYPASS DISCHARGEUL RECOGNIZED CATEGORY, PRGY2(E47185)CSA CERTIFIED, CLASS 1611 01(LR31393)

COMPRESSOR:1/12 HP OIL-LESS COMPRESSOR

VAC SHAMPOO & SPOT REMOVER INSTALLATION - 1 OF 2

Page 14: SPECIFICATIONS AND INSTALLATION INFORMATION

J.E. ADAMS INDUSTRIES, LTD ■ WE WORK HARDER TO PROVIDE YOU SOLUTIONS ■ WWW.JEADAMS.COM

14 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 0405

J.E. ADAMS VAC SHAMPOO INSTALLATION - 2 OF 2

Page 15: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 15

28000 AND 20000 INSTALLATION - 1 OF 2

28000

Page 16: SPECIFICATIONS AND INSTALLATION INFORMATION

J.E. ADAMS INDUSTRIES, LTD ■ WE WORK HARDER TO PROVIDE YOU SOLUTIONS ■ WWW.JEADAMS.COM

16 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 0405

28000 AND 20000 INSTALLATION - 1 OF 2

20000

Page 17: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 17

11000 & 12000 INSTALLATION - 1 OF 3

Page 18: SPECIFICATIONS AND INSTALLATION INFORMATION

J.E. ADAMS INDUSTRIES, LTD ■ WE WORK HARDER TO PROVIDE YOU SOLUTIONS ■ WWW.JEADAMS.COM

18 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 0405

11000 & 12000 INSTALLATION - 2 OF 3

Page 19: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 19

11000 & 12000 INSTALLATION - 3 OF 3

Page 20: SPECIFICATIONS AND INSTALLATION INFORMATION

J.E. ADAMS INDUSTRIES, LTD ■ WE WORK HARDER TO PROVIDE YOU SOLUTIONS ■ WWW.JEADAMS.COM

20 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 0405

SCENT MACHINE INSTALLATION

Page 21: SPECIFICATIONS AND INSTALLATION INFORMATION

PHONE 319-363-0237 ■ TOLL-FREE 800-553-8861 ■ TOLL-FREE FAX 866-252-6694 ■ FAX 319-363-3867

0405 CATEGORY 15: SPECIFICATIONS & INSTALLATION INFORMATION 21

SPECIFICATIONS: AIR MACHINES &AIR/WATER MACHINES

AIR: DEVILBISS COMPRESSOR20 AMP SERVICE REQUIRED110 VOLT, 14 AMPS60 HZ1.5 HORSEPOWERONE CYLINDERONE STAGEOIL-LESS

SCFM @ PSI:6 @ 05 @ 204.1 @ 403.1 @ 902.9 @ 1002.1 @ 125 (MAX PSI)

TEMPERATURE RANGE: -10 DEGREES F TO 100 DEGREES F.

MOTOR:1.5 HP, 1725 RPM, CAPACITOR START,NEMA 56 FRAME, AUTOMATIC THERMALOVERLOAD.

NO LUBRICATION REQUIRED ON MOTOR OR COMPRESSOR.

AIR: THOMAS COMPRESSOR20 AMP SERVICE REQUIRED110 VOLT, 10.6 AMPS60 HZ.75 HORSEPOWERONE CYLINDERONE STAGEOIL-LESS

SCFM @ PSI:3.78 @ 03.43 @ 203.04 @ 402.14 @ 901.99 @ 100125 (MAX PSI)

TEMPERATURE RANGE: -20 DEGREES F TO 104 DEGREES F.

MOTOR:.75 HP, 1700 RPM, CAPACITOR START,AUTOMATIC THERMAL OVERLOAD.

NO LUBRICATION REQUIRED ON MOTOR OR COMPRESSOR.

AIR MACHINE & AIR/WATER MACHINE INSTALLATION