1 / 23 Engineering Specifications For Model PCTLR-521A Double Pump Cementing Trailer (Picture for reference only)
Jan 20, 2016
1 / 23
Engineering Specifications
For
Model PCTLR-521A Double Pump Cementing Trailer
(Picture for reference only)
2 / 23
1. Description
Model PCTLR-521A Double Pump Cementer/Recirculating Mixing Trailer developed by
Serva SJS is the most advanced, accurate computer controlled cement mixing system
available. The quality of design, component selection, and quality manufacture makes
it a benchmark in the industry.
The high energy mixing system can mix the most difficult slurries and the ACM
automatic density control will provided superior density control. The pump unit can be
utilized for a variety of pumping services including acidizing, cementing, pressure
testing and fracturing within the limits of the available horsepower. The inline triplex
pump installation makes the maintenance and service of pumps easier.
This system is designed for minimum maintenance and operating in extremely harsh
environment with temperatures ranging from -25℃ to 55℃ and relative humidity up to
90%.
1.1 Components
The PCTLR-521A Double Pump Cementing trailer comprises of the following
components.
(1) 30t Semi-trailer Chassis
(2) CATERPILLAR C15 engine, 540 HP each
(2) ALLISON 4700 OFS transmission
(1) SERVA TPH400 X 4" Dia. Plunger Triplex Pump
(1) SERVA TPH400 X 4 1/2" Dia. Plunger Triplex Pump
(1) 8 bbl mixing tank
(1) 20 bbl displacement tank
(2) Mission 6x5 centrifugal pumps (slurry recirculation and transfer pumps)
(1) Mission 4x3 centrifugal pump (mix water or displacement fluid)
(1) High Energy Mixing system
(1) Density automatic Control System(ACM-IV.1) for density control
(1) Wireless Data Acquisition System (option)
(1) Auxiliary power pack, w/closed-loop hydraulic system, w/CAT C7 engine
(1) Air reservoir, 20 gal
(1) Fuel day tank 200 gal
3 / 23
1.2 Specifications
The PCTLR-521A trailer is comprised of high-pressure pumping system, high
energy recirculating mixing system, and all required controls and
instrumentation.
The high pressure pumping system consists of two diesel engines, two
automatic transmissions, and two triplex pumps. The fluid handling system
consists of centrifugal pumps for recirculation, boost and mix water. Manifold
consists of necessary piping, valves and connections to perform cementing
jobs.
Hydraulic system takes power from the auxiliary diesel engine, and drives fluid
handling and mixing equipment, including three centrifugal pumps and
agitators.
Triplex pumps are horizontal single acting plunger pumps and consist of fluid
end and power end. The fluid ends are made of three-piece forged steel and
are recommended for pumping cement, acid, water, drilling fluids and other
well service fluids.
Fluid ends size: right pump 4" Dia. Plunger; left pump 4 1/2” Dia. Plunger
Mixing system consists of a high-energy jet mixer, high rate recirculating pump
and tub agitator. The diffuser aids in removing air entrainment from bulk
cement. A densitometer is mounted in the recirculating line and the mix water
is measured with a turbine flow meter. The 8bbl mixing tank maintains the
ability to mix cement on the fly with good density control.
The displacement tank consists of two 10 bbl working volume compartments
with "barrel" marks. Tanks have full flow piping to rear of unit for ease of
cleanup.
Third dedicated centrifugal pump for dedicated boosting.
Control panel labeled in English only; panel gauge units in U.S and metric.
4 / 23
1.3 Operational Performance
2. Trailer chassis
The trailer chassis is a customer build, heavy duty, oil filed use, 30t anti-trailer.
TECHNICAL SPECIFICATION
Trailer
Chassis
Spec. of
Tractive Pin 2’’ (50)
Model No. of
Tyre
Meridian 12.00-20
Saddle Height
Without Load 1390mm Support Legs JOST
Axle BPW14010
(2NO.S) Span of Tyres 1300MM
Others ABS, 12V electric system
The trailer chassis must be equipped with bracket with lifting eyes to lifting the trailer.
3. Power System
Two (2) diesel engines drive two (2) high-pressure triplex pumps via automatic
transmissions and flexible drivelines.
Diesel Engines
Model: Caterpillar C15
Rated Power: 540HP@2100RPM
Lube oil pump, filter and cooling system
Fuel pump and filter system
Mode of Starting: Electric starter and Air start in both side of engine
Weight 27 t (approx.)
Dimension 11300 mm(L)X2500mm(W)X4200 mm(H)
Max. Pres 14,000 psi (96.5 MPa, 4” fluid end)
Max. Flow 2.7 m3/min (one 4” and one 4 1/2” Fluid End)
Density Range 1.3~2.6 g/cm3±0.024 g/cm
3
Mixing Capacity 1.9~14.5 BPM (0.3-2.3 m3/min)
Working Temp. -25ºC~50ºC
5 / 23
Cooling: Radiator and Fan.55deg c
Heavy-duty air filter, dry element type
Emergency kill for air intake shutdown
24 Alternator, equipped with 180aH capacity batteries.
15.7 CFM Air compressor with complete accessories.
Spark-arrest stainless steel muffler with flexible stainless steel connection
4. Power Distribution System
4.1 Transmissions
Allison 4700 OFS automatic transmission, completes with fill tube, dip stick gauge,
torque converter, and 1810 series output flange.
Gear ratios as follows:
1 st gear 7.63
2-nd gear 3.51
3 rd gear 1.91
4-th gear 1.43
5-th gear, 1.00
Gear ratios are selected manually, Reverse - Blocked out
4.2 Transmission Accessories
Oil pan with level gauge and filler tube
An engine mounted water to oil tube and shell cooling system
4.3 Drivelines
Heavy-duty drivelines are used between the transmissions and triplex pumps.
They are built with heavy-duty universal joints using 1810 series components.
Installation of drivelines is such that the manufacturer's maximum
recommended angle is not exceeded.
Each driveline is equipped with a metal guard assembly complete with
greasing access.
Manufacturer name & model: Spicer 1800 series, US
6 / 23
5. High Pressure Pumping System
5.1 Triplex Pumps
The TPH400 triplex pumps are good for high-pressure well service. Each pump
is equipped with an integral gear reduction box. The triplex pumps are designed
to pump cement slurries, sand-laden fluids, crude oil, acids, mud and other oil
well servicing fluids. The pumps have the following specifications.
Model TPH400
Power End
Type - Single acting Triplex
Configuration - Horizontal in line
Stoke - 8" (203.2 mm)
Maximum Rod Load - 170,000 lb (79,230360 kg)
Maximum input Horse Power - 600 BHP
Fluid End
Plunger Size Max Pressure PSI (Mpa) Max Flow m3/min(bmp)
4" (101.6) 14,000 (96.5) 1.20 (7.6)
4 1/2" (114.3) 11,200 (77.2) 1.52 (9.6)
Gear Box
Ratio - 8.4:1
Maximum input RPM - 2400 RPM
Coupling - Spicer 1800 series drive flange
Note: 4” and 4 1/2” plunger size is available.
Performance
Plunger dia
Displacement per rev
DISPLACEMENT AT PUMP STROKES PER MINUTES/PINION RPM
32 / 275 70 / 598 128 / 1099 171 / 1469 244 / 2100
Inch
(㎜) Gallon/rev (Liter/rev)
GPM (LPM)
PSI (MPa)
GPM (LPM)
PSI (MPa)
GPM (LPM)
PSI (MPa)
GPM (LPM)
PSI (MPa)
GPM (LPM)
PSI (MPa)
4” (101.6)
1.31 (4.94)
41.8 (158)
14000 (96.5)
91
(344)
7,150
(49.3)
167
(632)
3,896
(26.8)
223
(844)
2,918
(20.1)
319
(1206)
2,042
(14.1)
4 1/2” (114.3)
1.65 (6.25)
53 (200)
11200 (77.2)
115 (435)
5,658 (39)
211.3 (799)
3,079 (21.2)
282.2 (1068)
2,306 (15.9)
403.5 (1527)
1,610 (11.1)
7 / 23
HHP(Kw) 346(257) 380(283) 380(283) 380(283)) 380(283)
Note: The data above is based on 90%ME and 100%VE and 380HP hydraulic
horsepower —— Intermittent servicing only.
5.2 Power End Lubrication System
The power end lubrication system contains:
Pump
Bypass valve
Required plumbing and hoses
Heat exchanger
Pressure gauge
Temperature gauge
Full flow filter
Suction strainer
5.3 Plunger Packing Lubrication System
The plunger lubrication system is provided by a pressurized oil supply system.
The packing lubrication system contains:
Lube oil reservoir
Distribution manifold
Required plumbing and hoses
Pressure gauge
Pressure regulator
Flow control valves for each plunger with setting locks
6. Fluid Handling System
6.1 Fluid Displacement Tank
The displacement tank is a custom built stainless steel construction. It has a
working volume of 20 bbl and consists of two 10 bbl compartments each having
graduated markers measuring in increments of 1 bbl. The discharge ports from
the displacement tank are 152.4mm (6 in) butterfly valves leading into a 127 mm
(5 in) pipe that provides good velocity for gravity flow to boost pump and triplex
8 / 23
pumps. A flow back release line is provided to allow the triplex pumps pressure
to be discharged into the displacement tank. Standpipes provide overflow
protection with (3 in) butterfly valves located under the displacement tank. These
valves are connected to drain hoses to direct over-flow to desired location. Drain
valves are 76.2 mm (3 in) and connect to the over-flow line. They allow the
draining of each tank compartment. The piping manifold is designed with
sufficient couplings to allow complete disassembly of the piping.
Water input piping consist of 4 sets 4” port of the 3” fill up line.
6.2 Low-pressure piping
The suction manifold has a working pressure rating of 1.6 MPa. The manifold
includes various butterfly valves, which are convenient to operate, and
various flanges, couplings, union connections, pipe and fittings that are easy
to connect.
Fluid from the mixing tank connects to both the recirculating & boost pumps
or to the suction manifold for the two triplex plunger pumps. Fluid from the
recirculating pump can be pumped into mixing tank via the densitometer and
slurry mixer and into the suction manifold of the triplex pumps.
The suction manifold of the triplex pumps is supplied by either the transfer
pump or gravity fed from the line connecting the displacement tank.
A 76.2mm (3in.) fill manifold for filling the displacement tank from an external
mud or water supply is equipped with 76.2mon (3 in.) Weco style butterfly
valves, and 76.2mm (3 in.) coupling. An over pressure relief valve is included
to protect the system from receiving fluid with too much pressure.
Remote valves are air actuated.
9 / 23
7. Cement Mixing System
7.1 Introduction
The mixing system is a high-energy recirculating slurry mixer type. It consists of
a high energy jet mixer, diffuser, mixing tank, agitators and recirculating and mix
water pumps. The mixer design maximizes wetting of all cement by forcing the
dry bulk cement into and between the fresh water and the recirculating slurry.
The mix water centrifugal pump and the recirculating centrifugal pump provide
most of the high energy. The diffuser aids in removing air entrainment from the
bulk cement and eliminates dust in the mix tank. The 8bbl mixing tank allows
adequate residence time for good mixing and averaging of density with varying
bulk cement delivery. A hydraulic-driven paddle agitator in each tank provides
improved mixing and more homogenous slurry. The mix tub piping delivers fluid
to the suction manifold of the recirculating centrifugal pump via 6” piping.
The cement mixing system can be operated in a manual or automatic mode. In
manual mode the operator uses a manually operated hydraulic control valve to
control the cement-metering valve. In the automatic mode, an electro-hydraulic
10 / 23
control system operates the cement-metering valve. The electro-hydraulic
system is controlled by an industrial process controller/computer.
The mix tank has drain line under the tank.
7.2 ACM-IV.1 system
Model ACM-IV.1 Automatic Density & Tub Level Control Mixing System is an
advanced automatic controlled mixing system developed by Serva. It is
designed to help the operator maintain the desired density and a preset tub level
during the cementing job through inputting parameters, which greatly improves
the job performance and makes the operation much easier.
Specification
Density: 1.3~2.5 g/cm3
Density accuracy: ±0.024 g/cm3
Densitometer: 3” Micro Motion F300 non-radioactive densitometer
Cement valve: Patented off-center bulk cement metering valve
Mixer: Patented HEMI High energy recirculation mixer.
Level transmitter: “radar type” is NIVELCO.
Basic Operating Principle:
Bulk cement is pneumatically delivered to the HEMI mixer via cement metering
valve. This proportional valve controls the flow rate of the bulk cement, and a
transducer feeds back valve position to computer system. Flow rate of mixing
water is controlled by metering valve which is integrated in the mixer and
measured by a turbo flow meter. The tub level of mixing tank is monitored by an
radar level meter and will be fed back to the computer system. The 3”
densitometer located on the circulating piping system detects the actual density
and feeds it back to the computer.
The control software analyzes the measured tub level and triplex pump flow rate
and calculates a desired proportional water valve percentage open, then it
controls the mixing water flow to the designed point. As soon as the computer
system gets the water signal, it will compare the current measured density with
the desired value, then determine the new cement valve position to satisfy the
designed density.
11 / 23
Key Features
The screens and the function keys are designed according to the cementing
job features. The latest control software makes the control more accurate and
stable.
The 10” operating panel is used to makes it available to display more data
and real-time curves more clearly.
Data storage & communication module is used to store more than 100
cementing jobs data without data acquisition system support in real time.
The radar level meter works without the interference of the foam and
blending, which ensure the tub level can be accurately controlled.
The displacement tank high level and low level warning makes it possible to
monitor water supply remotely.
7.3 Mixing water Centrifugal Pump
The MISSION 4x3 mixing centrifugal pump will meet the following specification.
Model: MISSION 4X3
Suction: 4” pipe size
Discharge: 3” pipe size
Flow rate at 110 psi: 1.65 m3/min (10.4 bpm)
Maximum closed-in pressure: 1.17 MPa (170 psi)
The mixing water centrifugal pump takes on fluid from external sources or the
displacement tank through a manifold with 101.6 mm (4 in) piping and union
connections.
The pump can discharge fluid into the mix tub or displacement tank.
7.4 Recirculating Centrifugal Pump
The recirculating centrifugal pump has the following specifications.
Model: Mission 56
Suction: 6” pipe size
Discharge: 5” pipe size
Max. Flow rate at 64 psi: 3.7 m3/min (23 bpm)
12 / 23
Maximum closed-in pressure: 0.49 MPa (70 psi)
The recirculating centrifugal pump is capable of receiving fluid from the mixing
tub and discharge fluid back into the mix tub for recirculating.
7.5 Boost Centrifugal Pump
The boost centrifugal pump has the following specifications.
Model: Mission 56
Suction: 152 mm (6 in) pipe size
Discharge: 127 mm (5 in) pipe size
Flow rate at 64 psi: 3.7 m3/min (23 bpm)
Maximum closed-in pressure: 0.49 MPa (70 psi)
The boost centrifugal pump is capable of receiving fluid from the mixing tank,
and discharge fluid into the mix tub for recirculating or into the suction manifold
of the triplex pumps.
Note: The recirculation and boost pumps are dedicated pumps for their
respective functions but in case there was a problem with either pump, the other
pump can take the place of the inoperative pump or can take both functions at
the same time at a reduced rate.
8. Auxiliary power unit and Hydraulic System
The auxiliary power unit includes diesel engine, gear box and hydraulic system.
Engine: Model: CAT C7
300HP@2200RPM
W/ complete accessories, air compressor, starter, alternator, etc.
Gearbox: Funk, 3 output (SAE C)
Hydraulic System
Hydraulic system consists of 2 independent systems: one for closed loop
hydraulic pumps and the other for agitator open loop systems. The system
contains of stainless steel reservoir with sight gauge, filtration system, heat
exchanger, hoses and the other complete accessories.
The brand contains of Parker and Denison.
13 / 23
The hydraulic systems take power from the auxiliary diesel engine, and will drive
the following components:
Recirculating pump (close loop)
Boost centrifugal pump (close loop)
Mixing water centrifugal pump. (close loop)
Mix tub agitator (open loop)
Metering valve actuator (open loop)
9. High Pressure Discharge Manifold
All the discharge connector and piping are 2”, fig 1502
Rated working pressure of the exhaust manifold and the union: 105MPa
(15,000psi)
Rated working pressure for the plug valve and relief valve: 105MPa
(15,000psi)
Two triplex pumps can be manifolded together so as to be capable of
discharging simultaneously to the same outlet.
A flow back manifold (connected to the opposite side of the pump) connects
to the pressure release line with an open end connected to the displacement
tank. One 2" X1" 1502 plug valve control the release line.
Each of the pump discharge line has a safety valve.
Each of the pump discharge lines has a pressure transducer and 105MPa
(15,000 psi) mechanical pressure gauges.
The discharge manifold/valves are mounted firmly by a heavy duty mounting
system.
All treating iron should be FMC.
10. Operation and Display System
10.1 Operator Console
The Operator console is a custom built steel cabinet with a protective stainless
steel cover. The instrument panel is stainless steel with permanently engraved
labeling in English. The location of the console allows the operator a full view of
the various instruments and gauges of the console.
14 / 23
10.2 Deck Instrumentation
The main engine gauges includes tachometers, oil pressure, water
temperature, voltmeter, and warning lights that indicate low engine oil
pressure and high water temperature.
The transmission gauges includes the main oil pressure, lock-up clutch
indicator light, oil temperature.
Auxiliary engine gauges and relative controls.
The triplex pump gauges includes lube oil pressure gauge, oil temperature,
and an oil level gauge. The pressure and temperature gauges are switch
gauge type and activate a warning light whenever a certain level is reached.
A transducer and a mechanical diaphragm mounted on the triplex fluid-end
are utilized to measure the discharge pressure.
The unit is equipped with an over pressure protection system. When the
pressure of the pump reaches to a predetermined point, the computer
system will output a command to engine throttle system to bring the engine
to idle speed.
10” panel view for the parameter inputting and monitoring.
The hydraulic system has pressure gauges for each pump circuit and an oil
temperature gauge mounted in the console.
Console mounted pressure gauges are liquid filled with dual scale face
reading in standard U. S. units and metric units.
Mixing water pump is equipped with a flow meter and pressure gauge.
One push button emergency kill should be included for all engines shut off
simultaneously.
11. Wireless Data Acquisition System
Technical Specifications for Wireless Data Acquisition System
1. Radio Modem
15 / 23
(1) Operating Frequency
License-free, 2.4-2.4835 GHz
(2) Rated range
15 miles
(3) Output Power
100mv-1W
(4) Interface
Double RS232, Asynchronous, Full-duplex
(5) Connector
RS232
(6) Operating Modes
Point-to-point, Point-to-multipoint
(7) Operating Environment
Temperature, -40° to 75°C (-40° to +167°F)
Humidity, 0 to 95% non-condensing humidity
(8) Certification
FCC/IC/CE
2. Computer
(1) Standard operating temperature is -29° to 40°C, need heater when below
-30°C.
(2) Laptop, Panasonic Toughbook 31
(3) Vibration-resistant
(4) Data acquisition software with latest version. Display and record job data
in real-time, replay history data in chart, create and print data reports, run
screen in English language. Customization is available.
3. Power Supply
(1) When using 24VDC input,supply power for the radio modem by a
24VDC-12VDC power switch, supply power for the computer by a 300W power
inverter;
(2) When using 220VAC input, supply power for the radio modem by a
220VAC-12VDC power switch, supply power for the computer directly.
4. Cable Communication
16 / 23
Cable communication is also supported. Operators can use communication
cable to connect the equipment and the wireless data acquisition system to
transport data. Cable transportation distance is from 10 to 50 m.
12. Unitization and completion
To keep the equipment completion, the following items should be included.
Tool Box.
Lights and electric system.
Air system
Centrifugal pump Lubrication system
Bracket for high pressure iron and universal joint.
The instrumentation brand must be followed as below:
Description Brand
PLC&INSTRUMENTATION SIEMENS
DENSITOMETER EMERSON
GAUGES M/D, MURPHY,WIKA
13. Painting
The body loaded equipment will have the following finish and preparations:
All steel parts will be sand blasted to white metal
Primer will be zinc rich
Color will be polyurethane paint with catalyst
Clear yellow coat
The brands: International or Jotun
14. Tools and Spare Parts
14.1 Tools
Description Quantity
Hammer (2.7 Kg) 1
Hammer with plastic handle (4 pound) 1
17 / 23
Pipe clamp (24” 18”) 1
Metric system allen key (1/4~1 1/2) 1
English system allen key (1/4~1 1/2) 1
Electronic tool assembly 1
Circuit tester 1
Universal wrench (3/8”~1 1/2”) 1
Wire clamp 1
Grease gun 1
Hacksaw 1
Vise grip 1
Pliers 1
Socket spanner (12 14) 1
Chisel (1/2~1) 1
Screw driver (flat tip and phillips tip) 1
Punch 1
Wrench (used to fill fuel, chain) 1
Special tools for plunger pump 1
Seat puller 1
Tools box 1
14.2 Spare parts
Master fuel filter , C15 1
Auxiliary fuel filter, C15 1
Engine oil filter, C15 1
Air filter element , C15 1
Element, transmission 1
Master fuel filter , C7 1
Auxiliary fuel filter, C7 1
Engine oil filter, C7 1
Air filter element , C7 1
Packing, 4” fluid end 3 set
Packing, 4 1/2” fluid end 3 set
18 / 23
Packing, 5X6 Centrifugal pump 2 set
Element,Filter,Power End Lube 1
Element,Filter Return 2
15. Documentation
Trailer, Engine, Transmission, Triplex pump, Centrifugal pump operation manual
2 set
Engine, transmission parts manual. 2 set.
PCTLR-521A double pump cementer trailer operation and maintenance manual. 2 set
ACM-IV.1 density auto control system operation manual. 2 set
CD of all abve manuals 2set
16. Warranty
STATEMENT OF WARRANTY POLICY
1. Serva SJS. ("SJS") warrants the Equipment to be free from defects in material
and workmanship for a period of eighteen (18) months from the Date of
receiving the unit.
2. SJS reserves the right to inspect the Equipment to determine the validity of the
warranty claim and if determined to be valid, SJS will, at its option: (1) replace
the defective Equipment or parts thereof; or (2) authorize the Equipment or part
to be returned to its authorized repair facility for repair; or (3) authorize the
Equipment or part to be repaired at your plant. SJS will not be responsible for
any transportation costs.
3. Repair or replacement will be without charge, but removal and installation of
other parts, including additional parts furnished, will be made at Purchaser's
expense. No charges will be accepted for returns, repairs or alternations done
by the Purchaser unless previously authorized in writing by SJS.
4. Purchaser acknowledges that the Equipment is of a size, design and type
requested by the Purchaser and agrees that, except as stated herein, there are
19 / 23
no other warranties, express or implied, including those or merchantability or
fitness for particular use, which SJS hereby disclaims.
5. Purchaser to pay all charges for travel time, kilometer charges and travel
expenses for warranty work performed away from the SJS facility.
NOT COVERED UNDER THIS WARRANTY
1. Equipment or parts manufactured by others however, SJS will assign the
benefits of any manufacturers ' warranty if assignable.
2. Equipment or parts that are or have been in contact with corrosive chemicals or
corrosive materials.
3. Equipment, fluids or parts customarily subject to wear.
4. Failure resulting from improper use or inadequate maintenance.
5. Personal injuries or death to any person (including the Purchaser and any of its
employees, agents and contractors) or claims for loss or damage to property or
business either direct, indirect or consequential, caused or contributed to by the
Equipment or any failure thereof, regardless of whether caused by SJS or any
other person or by any default or negligence of SJS, its employees, agents and
contractors.
20 / 23
The Treating iron list
Qty Description PN (SJ)
12 Discharge pipe joints 2”(10’long) X05-91-700
6 Discharge pipe joints 2”(6’long) X05-91-005
3 2”x1”plug valve X05-91-602
3 2”x2”plug valve X05-91-473
6 2”style 50 two way swivel joints X05-91-170
4 2”style 10 three way swivel joints X05-91-229
5 2”chicksan hose(one50-one10)1502union X05-91-197
2 2”adapters change over nipple integral union nut nut X05-91-331
2 2”Adapters change over nipple intergral union thread X tread X05-91-283
2 2”tee (wing to thread) X05-91-293
2 2” check valve (standard flow) X05-91-111
1 2”Y(wing to thread) X05-91-163
4 4”x 10’long loading hose with fig 206 unions X04-09-871
1 4” X 20’ long reg hose (rated to 250 PSi)with fig.206 unions X04-09-870
Spare parts list (recommended for 2 years)
Item Qty. Part No. Description
1 4 X04-01-027 Element, Master fuel filter, C15
2 4 X04-04-280 Element, Auxiliary fuel filter, C15
3 4 X04-04-276 Element, Engine oil filter, C15
4 4 X04-04-306 Element, Air filter, C15
5 4 X04-04-306 Element, Oil filter, 4700OFS
6 2 X04-04-627 Element, As-primary, air cleaner, Cat C7
7 2 X04-04-659 Element, As-secondary, air cleaner, Cat C7
8 2 X04-04-626 Filter, engine oil, Cat C7
9 2 X04-01-635 Filter, fuel, C7
10 2 X04-04-625 Belt, Cat C7
11 16 V06-54-820 Packing,RA56 pump
21 / 23
12 4 X04-04-283 Element, return filter
13 3 X04-00-587 Element, charge
14 2 X04-09-155 Element, power end lube
15 1 B10-12-059 Repair kit, high energy mixer
16 1 B10-17-311 Repair kit, Cement metering valve
17 2 X04-02-502 Ring,2 1/2” Victaulic coupling
18 8 X04-02-503 Ring, 3” Victaulic coupling
19 8 X04-02-504 Ring, 4” Victaulic coupling
20 8 X04-02-505 Ring, 5” Victaulic coupling
21 8 X04-02-506 Ring, 6” Victaulic coupling
22 2 F32-29-885 Valve, butterfly 3”
23 4 F32-29-886 Valve, butterfly 4”
24 4 F32-29-887 Valve, butterfly 5”
25 2 F32-29-888 Valve, butterfly 6”
26 2 A170014000 O-ring, 5 1/2" union
27 4 V06-67-707 Actuator,3-6" butterfly valve
28 4 X05-91-472 Repair kit, 2" 1502 Plug Vavle
29 2 X05-91-568 Repair kit, 1" 1502 Plug Vavle
30 10 X05-91-296 Seal, 1502 union
TRIPLEX PUMP W/4 " FLUID END
1 12 P40-40-108 Insert, polyurethane
2 12 P40-40-107 Valve, frac no.4 frac
3 12 P40-40-109 Seat, valve, tapered no.4 frac
4 12 000P569240 O-ring, nitrile 90 duro
5 12 P8T0009400 Packing,sps,assy,4”ph400
6 6 P40-40-533 Plunger, short tie bolt
7 12 P40-40-112 Insert, for two-piece bushing
8 6 P40-40-106 Spring, valve, stainless
9 12 P40-40-103 Gasket,no.4 discharge valve,4"
10 12 P40-40-709 Ring,spacer,no.4 discharge valve, 4"
11 12 P40-40-215 Boot, suction stop
22 / 23
12 6 P40-13-013 Shoe top, crosshead
13 6 P40-13-019 Shoe bottom, crosshead
14 4 P40-40-104 Seal, oil
15 6 P40-40-512 Seal assembly, plunger nose, 4"
16 6 000P569432 O-ring, nitrile 90 duro
17 8 P40-40-612 Seal, discharge passage
TRIPLEX PUMP W/4 1/2" FLUID END
1 12 P40-44-108 Insert, polyurethane
2 12 P40-44-107 Valve, frac no.4 frac
3 12 P40-44-109 Seat, valve, tapered no.4 frac
4 12 000P569244 O-ring, nitrile 90 duro #244
5 12 P8T0009450 Packing,sps,assy,4.500,tph400
6 6 P40-44-533 Plunger, short tie bolt
7 12 P40-40-112 Insert, for two-piece bushing
8 6 P40-44-106 Spring,valve,25lb/in,stainless
9 12 P40-40-103 Gasket,no.4 discharge valve,4 1/2"
10 12 P40-44-709 Ring,spacer,no.4 discharge valve, 4 1/2"
11 12 P40-44-213 Spring,lock,no.4 suction stop
12 12 P40-40-215 Boot, Suction stop,
13 12 P40-44-215 Retainer, stop and spring
14 12 P40-13-013 Shoe top, crosshead
15 12 P40-13-019 Shoe bottom, crosshead
16 4 P40-14-104 Seal, oil
17 12 P40-44-512 Seal assembly, plunger nose,4 1/2"
18 12 000P569436 O-ring, Nitrile 90 Duro #436
19 12 000P569432 O-ring, Nitrile 90 Duro #432
20 8 P40-40-612 Seal, discharge passage, 3 3/8" O.D.
23 / 23
Martin Decker Data Recorder
The unit should also be equipped with Dual Input Martin Decker Pressure Chart
recorder.
Model: M365-series
Working Pressure: 15,000 PSI
Portable recorder with 5” pressure gauges
~~OVER~~