ALPHARD SERIES LED ALUMINIUM CEILING LIGHT LED LUMINAIRE IP65 IK10 SHANGHAI P&Q LIGHTING CO., LTD PRODUCT NAME: ALPHARD VERSION: 9W, 12W, 18W, 24W LED DIMENSION(MM): Φ295×83 BODY MATERIAL: ALUMINIUM DIFFUSER MATERIAL: PC ALPHARD SERIES SPECIFICATION LED CEILING LIGHT
7
Embed
SPECIFICATION ALPHARD SERIESq.zvk9.com/1645/2018/03/19/ALPHARD SPECIFICATION M2.pdf · 19.03.2018 · alphard series led aluminium ceiling light led luminaire ip65 ik10 shanghai
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ALPHARD SERIES LED ALUMINIUM CEILING LIGHTLED LUMINAIRE IP65 IK10
SHANGHAI P&Q LIGHTING CO., LTD
PRODUCT NAME: ALPHARDVERSION: 9W, 12W, 18W, 24W LEDDIMENSION(MM): Φ295×83 BODY MATERIAL: ALUMINIUMDIFFUSER MATERIAL: PC
ALPHARD SERIESSPECIFICATION
LED CEILING LIGHT
CATALOGUE
PARTS LISTS & EXPLODED ASSEMBLY DRAWINGS PAGE 3
QUICK SPECIFICATION & LIGHT DISTRIBUTION PAGE 4
SPECIFICATION PAGE 5
INSTALLATION INSTRUCTION PAGE 6
PACKING INFORMATION & CONTACT INFORMATION PAGE 7
PARTS LISTS & EXPLODED ASSEMBLY DRAWINGS
EXPLODED ASSEMBLY DRAWINGS
NOTE :
1. ALPHARD SERIES HAVE THREE VERSIONS: NORMAL VERSION, MICROWAVE SENSOR VERSION AND EMERGENCY VERSION.2. NORMAL VERSION INCLUDE NO.1, NO.2, NO.4, NO.6, NO.7, NO.8, NO.9 ON THE PARTS LISTS.3. MICROWAVE SENSOR VERSION INCLUDE NO.1, NO.2, NO.4, NO.5, NO.6, NO.7, NO.8, NO.9 ON THE PARTS LISTS. 4. EMERGENCY VERSION INCLUDE NO.1, NO.2, NO.3, NO.4, NO.6, NO.7, NO.8, NO.9 ON THE PARTS LISTS.
5
6
7
8
PARTS LIST
1. EMERGENCY SYSTEM ×1
2. SCREW HOLE COVER ×3
3. PC DIFFUSER ×1
4. PCB & LED CHIPS ×1
5. REFLECTOR ×1
6. MICROWAVE SENSOR ×1
7. DRIVER ×1
8. ALUMINIUM DIE CASTING BODY ×1
9. SETSCREW ×4
9
4
2
3
1
0 1530
345330
315 45
300 60
285 75
90270255 105
600
500
400
300
200
100
QUICK SPECIFICATION & LIGHT DISTRIBUTION
FEATURES
● AVERAGE RATED LED LAMP LIFE OF 50,000 HOURS AT L70 IN TA40C ENVIRONMENTS.● DURABLE ALUMINIUM BODY OPTIONS. ● HIGH PERFORMANCE OPTICS WITH IMPROVED ILLUMINATION UNIFORMITY.● UV RESISTANT MOULDED LENS WITH INTEGRAL IP65 SILICONE SEAL.● SUITS STANDARD DIAMETER 34MM POLES AND SPIGOT BRACKETS.● THREE VERSIONS: NORMAL, SENSOR AND EMERGENCY SYSTEM.● FOUR RATE POWER: 9W, 12W, 18W, 24W.● LOW PROFILE IP65 PROTECTION, IK10. ● AMBIENT TEMPERATURE, -25°C TO 40°C.
APPLICATIONS
PRISONS, SUBWAYS, RAILWAY STATIONS ANDUNDERGROUND CARPARKS, PERSONAL HOUSE.
VERSION DIM (MM) MASS (KG)---------------------------------------------------------------------------------------------------------- 9W LED Φ295×83 1.5 9W LED SENSOR Φ295×83 1.8 9W LED EMERGENCY Φ295×83 2.212W LED Φ295×83 1.512W LED SENSOR Φ295×83 1.812W LED EMERGENCY Φ295×83 2.218W LED Φ295×83 1.518W LED SENSOR Φ295×83 1.818W LED EMERGENCY Φ295×83 2.224W LED Φ295×83 1.524W LED SENSOR Φ295×83 1.824W LED EMERGENCY Φ295×83 2.2
PLEASE READ THESE INSTALLATION INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR MAINTAINING THISEQUIPMENT. THESE INSTRUCTIONS AND LOCAL REGULATIONS(WHERE APPLICABLE), BY AN AUTHORISED AND LICENCED ELECTRICIAN.
IMPORTANT – THE PRODUCT MUST BE MAINTAINED AND OPERATED IN ACCORDANCE WITH THE MANUFACTURE’S INSTRUCTIONS, FAILURE TO DO SO MAY DAMAGE THE PRODUCT AND SERVICES. IT IS STRONGLY RECOMMENDED THAT THIS IMPORTANT NOTE BE COMMUNICATED TO THE OWNER AND OR OPERATOR OF THE INSTALLATION AT THE TIME OF SITE COMMISSIONING. GOOD PRACTICE DOES NOT RECOMMEND THE 24/7 USE OF PRODUCTS WITHOUT THE APPLICATION OF SUITABLE SWITCH CYCLE INTERVALS. P&Q IS NOT RESPONSIBLE FOR ANY PRODUCT NOT MAINTAINED IN ACCORDANCE WITH THE RECOMMENDED PROCEDURES. ALL PRODUCTS SHOULD BE THOROUGHLY CLEANED ON A REGULAR BASIS TO ENSURE THE OPTICAL PERFORMANCE, TOGETHER WITH THE ELECTRICAL,MECHANICAL AND STRUCTURAL INTEGRITY AS DESIGNED, IS MAINTAINED THROUGHOUT THE SERVICE LIFE OF THE PRODUCT.
“CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR”
1. PRODUCT SPECIFICATION:
ALPHARD———————————————————————————————————————————————————————————————IP RATING IP65———————————————————————————————————————————————————————————————NOMINAL VOLTAGE AC180-240V ———————————————————————————————————————————————————————————————LINE CURRENT 0.5A ———————————————————————————————————————————————————————————————
2. STORAGE: PRIOR TO INSTALLATION PRODUCTS ARE TO BE STORED IN COOL AND DRY CONDITIONS.
3. INSTALLATION DRAWINGS
STEP 1: DRILL FOUR Φ6MM HOLES IN THE CEILING AND THEN PUT THE SETSCREW INTO THE HOLE.STEP 2: TAKE OFF THE ENCLOSER AND THE REFECTER.STEP 3: INSTALL THE BASE ON THE CEILING.STEP 4: INSTALL THE ENCLOSER AND THE REFECTER ON THE BASE.
4. ELECTRICAL FAULT FINDING AND RELACEMENT: THE SUPPLY MUST BE ISOLATED BEFORE OPENING THE LUMINAIRE. IF ALL CONNECTIONS ARE VERIFIED TO BE CORRECT, THE PRODUCTS ENVIRONMENT MAY BE HAVING AN ADVERSE EFFECT TO THE COMPONENTS. IF THIS IS THE CASE PLEASE CONTACT YOUR SUPPLIER FOR A MORE SUITABLE REPLACEMENT. ANY FAULT FINDING MUST BE DONE BY A FULLY QUALIFIED ELECTRICIAN AND, IF CARRIED OUT WITH THE LUMINAIRE IN PLACE, UNDER A PERMIT TO WORK. WITH REPLACEMENT OF ANY PART ENSURE THAT WIRES AND CONNECTIONS ARE CHECKED, AND ANY WIRE SLEEVING REFITTED.
STEP 1 STEP 2 STEP 3 STEP 4
PACKING INFORMATION & CONTACT INFORMATION
PACKING INFORMATION
1
1. 302×302×110MM INNER BOX
2. ALPHARD CEILING LIGHT
3. 625×315×595MM OUTER BOX
4. EXPENDED PLASTIC COVER
10 PCS / 1 OUTER BOX
1
2
3
4
ADDRESS
COMPANY ADDRESS ROOM 507, NO. 423 XINCUN RD. PUTUO DIST. SHANGHAI, CHINA