SPEC SHEET NETWORK MONITORING! Impressive integration features and eight communication paths • Create, configure and manage up to eight communication paths between the panel and Central Station • On-board Ethernet connection • Flash Updateable: No more firmware chips to replace • Provides up to 500 DMP 1100X Wireless devices • Adaptive Technology™ instantly transfers standard line supervision from primary to backup paths • UL Listed for Burglary, Fire, Access Control DMP XR500 Series Command Processor™ Panels meet all your burglary, fire and access control integration needs. XR500 SERIES ACCESS/BURGLARY/FIRE 574-ZONE COMMAND PROCESSOR™ PANEL SYSTEM FEATURES • Select Area, All/Perimeter, or Home/Sleep/Away operation • 32 individual reporting areas, with common areas • Up to 16 supervised door access-points and/or keypads • Output Groups: Maximum functionality—Minimum programming • Up to 502 fully-programmable Form C relays • Up to 562 two-wire smoke detector or fire-initiating zones • 10,000 user codes with 99 profiles • 12,000 event buffer • Up to four independent shift schedules per area OR use one shift schedule to control all areas • Up to 100 output schedules to control relays and panel outputs • Up to 20 holiday dates for shift and output schedules • Serial 3 digital dialer or CID reporting to multiple receivers • Built-in phone line monitor • Built-in DB-9 RS-232 or LX-Bus (Selectable) • Multi-lingual menus available • 1.5 Amps 12 VDC smoke and auxiliary output with OVC protection • 16.5 VAC 50 VAplug-in transformer included • 1.5 Amps 12 VDC supervised bell output XR500N/XR500E SYSTEM FEATURES • On-board Ethernet • Bank, Safe and Vault Operation • Two Man Rule, Panic Button Test and Early MorningAmbush XR500E SYSTEM FEATURES • Built-in AES (Advanced Encryption Standard) Encryption • NIST Certified and UL Listed Encryption • Unique user-programmable passphrase for greater security NYC MEA
4
Embed
SPEC SHEET - d2beia7gtp5yjy.cloudfront.netd2beia7gtp5yjy.cloudfront.net/cdn_image/df/61a85/33246689/19283/... · SPEC SHEET EvENTS MANAGER ... Automatically download them to the receiver
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
SPEC SHEET
NETWORK MONITORING!
Impressive integration features and eight communication paths
XR500N/XR500E SYSTEM FEATURES• On-boardEthernet• Bank,SafeandVaultOperation• TwoManRule,PanicButtonTestandEarlyMorningAmbush
XR500E SYSTEM FEATURES• Built-inAES(AdvancedEncryptionStandard)Encryption• NISTCertifiedandULListedEncryption• Uniqueuser-programmablepassphraseforgreatersecurity
NYCMEA
XR500 SERIES
FLEXIBLE COMMUNICATIONThe XR500N has transitioned from dialer-focusedcommunicationstoatruenetworkand cellular communications approach byproviding stronger, multi-layered panelcommunications that ensure a constantlink between the panel and CentralStation. Installers have the ability tocreate, configureandmanageup toeightcommunicationpaths.
The unique DMP Serial 3 format supports16-characteruser,zoneandareanamestodecreasethecentralstationresponsetimeandlimitdependenceonautomationliteraltablesformessageconversion.
ENCRYPTIONThe XR500E provides encrypted datatransmission and is ideal for secureenvironments where encrypted data isrequired.UsingAES (Advanced EncryptionStandard) Encryption ensures secure datatransmissionbyusingauniquealphanumericpassphrase. UL Listed and NIST CertifiedEncryption.
NETwORk OR CELLULAR COMMUNICATIONBuilt-inEthernetCommunicationsenhancenetworkoptionsandprovidesStandardandEncryptedLineSecurity.BothUDPandTCParesupported.Thenetworkoptioncanbeusedastheprimarypathorasabackuppathtothedigitaldialerorcellularoption.
The 463G p lug- in D ig i ta l Cel lu larCommunicatorcanbeusedastheprimarypath, providing installation flexibilitywhere no land lines are available. Usedas the backup path, the 463G providesthe securityofa communication link thatcontinuestofunction,evenwhenlandlinesare cut or compromised. This interfaceworks on digital Cellular GSM/GPRS datanetworks over a variety of carriers in theUSAandCanada.
EIGHT COMMUNICATION PATHSCreate,configureandmanageuptoeightcommunicationpathsbetweenthepanelandCentralStation.Eachpathhasitsownpanelcommunication programming parameters,andcanbeidentifiedaseitherprimaryorbackup.Thisenablesinstallerstoconfigurea reliable communication link, offeringgreaterconfidencethatthepanelwillalwaysbeconnectedtotheCentralStation
ADAPTIvE TECHNOLOGYIf a current primary communication pathbecomesunavailable,AdaptiveTechnologydirects the panel to make a seamlesstransitionfromonecommunicationpathtoanotherwithinmilliseconds,ensuringthatnocheck-inorsupervisionmessagesaremissed.Thisallowsasystemtobefullysupervisedwhen the primary communication path isunavailable,whileminimizingexpensivecelltrafficwhenallpathsaregood.Thepanelisconstantlycheckingthefailedpathtoenablethepaneltorevertbacktotheprimarypathwhencommunicationisrestored.
BUILT-IN PROGRAMMER AND DIAGNOSTICSEnablesinstallersandservicetechnicianstofullyprogramthesystemandrundiagnosticsfromanyDMPLCDkeypad.
CANCEL/vERIFYIn a Home/Sleep/Away orAll/Perimetersystem,CANCELaburglaryalarmorVERIFYthat a valid burglar alarm has occurred.SelectingVERIFYmanuallyverifiesthealarmandanalarmverificationmessageissenttotheCentralStation.
FLASH UPDATEABLEThe XR500 Series panel accepts softwareupdates from a remote location usingRemote Link™ software.As new XR500featureupdatesrelease,performtheflashupdateremotely.
AREASProgram up to 32 areaswith a variety ofoptions,includingindependentarming.Eachareahasauniquenameandmayhave itsownaccountnumber.Common areas automatically arm whenthe last independent area is armed anddisarmwhenthefirst independentarea isdisarmed.Thisisidealforlobbiesorareaswhereusersneedcommonaccesstospecificareasonly.
ALL/PERIMETER OR HOME/SLEEP/AwAY OPTIONSThe XR500 Series panels support All/PerimeterorHome/Sleep/Awayoperation.WhenAll/Perimeteroperation is selected,Area1isthePerimeterandcanbeseparatelyarmed allowingArea 2, the Interior, toremainunarmedwhileyouareinside.When Home/Sleep/Away operation isselected,Areas 1 and 2 operate as in anAll/Perimetersystem.Area3istheBedroomareaandallowsuserstoarmtheperimeterand interior at night while leaving thebedroomareadisarmed.
DMP wIRELESSTheeasilyprogrammable900MHzfrequency-hopping spread-spectrum DMP1100XSerieswirelesssystemfeaturesTwo-waycommunicationforsuperioroperation,supervision and battery life. Two-waycommunication minimizes repetitivesignaling and helps to quickly identifymissingtransmitters.Simplekeypadaccesscanbeusedtoverifythatwirelessdevicezonesareinworkingorder.
ZONE EXPANSIONThe XR500 provides up to 574 zones,programmableforburglary,fireandaccessapplications. The system contains eightburglary zones and two Class B 12VDCpoweredzones.Upto64zonesareavailableon16keypadaddressesandupto100zonesareavailableonthebuilt-inLX-Bus.Addupto500zonesusingExpansionModules.
CROSS-ZONINGThis powerful feature allows zones to beprogrammed to report alarms onlywhenone ormore zones trip twicewithin 4 to250programmableseconds.Ifonlyonezonetripswithinthespecifiedtime,afaultreportissenttothecentralstation.
10,000 USER CODESEach user can be assigned to one of 99different profiles that provide access toanycombinationofareas.
12,000 EvENT MEMORYThe Display Events feature allows usersto view up to 2,000 stored openings andclosings, zone events, user code andschedule changes and supervisory events.Sorteventsbyaparticularuser,dooranddate range.The remaining 10,000 eventsdetaildooraccessgrantedeventsseparatelyforeasy review.EventsmaybeviewedatanysystemkeypadoruploadedtoRemoteLink™software.
SPEC SHEET
EvENTS MANAGERSavedial-upmonitoringcostsbyusingtheEvents Manager option to buffer specificnon-alarmreports.AutomaticallydownloadthemtothereceiverwhenmemoryisfullorkeeptheminmemoryuntildownloadedwithDMPRemoteLink™Software.
FIRE DRILL AND ONE-MAN wALk TESTUsers can test fire notification bells usingthe Fire Drill feature.A special code isalso available for installers to test thesystem. The one-man walk test featureallows a single technician to check thepanelresponsetoburglary,fire,panicandsupervisoryzones.
OUTPUTSTheXR500allowstheuseoftwoSPDTrelayoutputs and four open-collector outputs,whichmaybeactivatedbyzoneorsystemevents,byschedule,throughtheUserMenuorwhenacardispresented.OutputGroupsallowmultiple outputs to activatewith asingle event and/or can be assigned to aparticularuserprofile.Upto500outputsareavailableontheXR500LX-Buswhenoptionaloutputexpandersareused.
OUTPUT SCHEDULESAchievemaximum system flexibilitywith100programmableschedulesthatsimplifyplanning and operations. Control anycontact-activated device with schedulesthat automatically regulate relays andswitched-groundoutputs.
DOOR STRIkE SCHEDULES wITH OvERRIDESpecificdoorsmayuseoutputschedulestounlock during certain times of the day ornight,orthecardreadercanbecompletelydisabled when desired. The scheduleoverridefeaturekeepsdoorslockedshouldthebusinessopenlaterorcloseearlierthanscheduled.
MULTI-LINGUAL DISPLAY OPTIONXR500SeriessystemsmaybeprogrammedtodisplaytheUserMenuandStatusDisplaytextinmultiplelanguages.WhentheCommandkey is pressed, the option to choose alanguage displays. Select the languageto use.The language chosen continues todisplayatthekeypaduntilanotherlanguageischosen.
SHIFT SCHEDULES wITH HOLIDAYSUp to four independent Shift schedulesare available for each of the 32 areas.Shift schedules are usedwhen areas areprogrammed to automatically arm ordisarmandtotransmitareaLate-to-Closereports. Shift schedules are assigned touser authorities, called Profiles, to definescheduled permissions for system users.Override normal day-to-day schedules upto a year in advancewith up to 20 user-selectable Holiday Dates. Independentholiday schedules are available for eachshift,outputanddoor-strikeschedule.
kEYPAD SHORTCUT kEYS Keypad shortcut keys are provided tosimplify operation and allow the user toarm,monitororresetthesystem.
ACCESS CONTROLThe XR500 system can restrict access byschedule, arming level or other criteria.The specific reason for access denial canbe displayed on the keypad, stored inevents,loggedonalocalprinter(DMP462Prequired),senttothecentralstationandtoDMPAdvancedReportingsoftware.
THINLINE™ AND AqUALITE™ kEYPADSThe stylish and sleek 7000 Series keypadsprovide three 2-button Panic keys, ACpower and Armed LEDs, 32-characterdisplay,backlit logoandkeyboardplusaninternal speaker.Aqualite Series keypadsoffer a brilliantAqua colored LCD displayandbacklighting.
Aqualite/Thinline Keypad
vALUABLE vISUAL ALARM INDICATOR In a normal state, both the keypad andlogo backlighting remain Blue onAqualitekeypads or Green on Thinline keypads.However,duringanalarmstate,thekeypadandlogoturnRed.Thechangeincolorallowspersons on-site to instantly recognize analarmcondition.
Red Backlighting for Alarm Conditions
7760 CLEAR TOUCH™Anattractivenewuserinterfacefeaturingaglasstouchscreeninsteadoftraditionalkeys.TheBluetouchscreendisplayturnsRedforalarmconditions.AvailableinWhite,Blackor Platinum, the 7760 adds elegance andstyletoanyinstallation.
7760 Clear Touch™ Keypad
16 INDEPENDENT ACCESS CONTROL DOORS Anyaccesscontrolreaderwitha26-40bitWiegand output can be connected to theXR500 Series panel.Attach card readerinputstoupto16differentlocations.
ANTI-PASSBACkSpecificdoorsandreaderscanbedesignatedforaccessto,oregressfrom,specificareasinthesystem.Thisoperationrequiresuserstocardinandcardoutofaspecificarea.Users failing to egress the area are notallowed access into the area again untilauthorizedbythesystemadministrator.