Top Banner
2007.08.24 Prof. Masatsugu NAGAI Nagaoka University of Technology Span limitation of steel self-anchored cable-stayed bridges
23

Span limitation of steel self-anchored cable-stayed bridges

Feb 19, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Span limitation of steel self-anchored cable-stayed bridges

2007.08.24

Prof. Masatsugu NAGAI

Nagaoka University of Technology

Span limitation of steel self-anchored

cable-stayed bridges

Page 2: Span limitation of steel self-anchored cable-stayed bridges

Introduction of long-span bridges

related

プレゼンター
プレゼンテーションのノート
Design & Technical Committee
Page 3: Span limitation of steel self-anchored cable-stayed bridges

Katsushika Harp Bridge (Tokyo)

Page 4: Span limitation of steel self-anchored cable-stayed bridges

Tatara Bridge (Hiroshima-Ehime)

Page 5: Span limitation of steel self-anchored cable-stayed bridges

1) Span Limitation of Steel (Self-anchored) Cable-stayed Bridges

2) Possibility of further span extension by Partially Earth-anchored System

3) Economical tower height is 1/5 of the span???

My topics today

Page 6: Span limitation of steel self-anchored cable-stayed bridges

Cable-stayed System

Partially earth-anchored system

+

--

- -CL

CLaxial force

axial force

earth anchor

Self-anchored system

Partially earth-anchored system

+

--

- -CLCL

CLCLaxial force

axial force

earth anchor

Self-anchored system

Page 7: Span limitation of steel self-anchored cable-stayed bridges

How far

it can span?????

Objective (of my first topic)

(identification)

Page 8: Span limitation of steel self-anchored cable-stayed bridges

1) Mechanical viewpoint

2) Economical viewpoint

We have to take into account two aspects

Page 9: Span limitation of steel self-anchored cable-stayed bridges

Competition

From economical viewpoint!!

Cable-stayed bridges

vs.

Suspension bridges

Page 10: Span limitation of steel self-anchored cable-stayed bridges

What is the key point (subject)

to identify???

⇒ design main girder

with minimum size (min. steel volume) (ensuring safety against

static and dynamic instabilities)

Page 11: Span limitation of steel self-anchored cable-stayed bridges

Analytical approach

1) Elaso-plastic finite displacement analysis under in-plane load

2) Finite displacement analysis under displacement-dependent wind loading

3) Flutter analysis using multi-modal coordinate (complex eigen value analysis)

Page 12: Span limitation of steel self-anchored cable-stayed bridges

-Competition (Key factor)-

to identify min. size of cross section

of girder ensuring safety

against static & dynamic instabilities

プレゼンター
プレゼンテーションのノート
Page 13: Span limitation of steel self-anchored cable-stayed bridges

1) Minimum width of box girder

Lc(span)/B(girder width)

should be less than 40 (Leonhardt’s recommendation)

Is it valid???

Page 14: Span limitation of steel self-anchored cable-stayed bridges

(a) side view

(b) girder section (c) tower

Cable-stayed bridge model

Page 15: Span limitation of steel self-anchored cable-stayed bridges

1,400-m Cable-stayed Bridge Model

(a) Side-view (plan)

(b) Cross section of girder

(c) Increase of plate thickness

20

A BXu Xu

3@100=300

380680

20 20 6601400

20

(m)

C

CL

120.04

10 Bridge axis directio

10

132

148

740

46

280

47

(d) Tower

30Tup

0.015

0.02

0.008

1.5

x2%

y

Bu

hw

5O

Page 16: Span limitation of steel self-anchored cable-stayed bridges

since V(divergence) < V(flutter)

Important parameters to enhance V(divergence)

under wind load are

1) In-pane flexural rigidity of the system

2) Torsional rigidity of the system

Effect of increase out-of-plane flexural rigidity

will be minor

Page 17: Span limitation of steel self-anchored cable-stayed bridges

Cable-stayed System

Partially earth-anchored system

+

--

- -CL

CLaxial force

axial force

earth anchor

Self-anchored system

Partially earth-anchored system

+

--

- -CLCL

CLCLaxial force

axial force

earth anchor

Self-anchored system

N(+) = N(-) ⇒ Lc (Partially earth-anchored) = Lc(Self-anchored) 2

Page 18: Span limitation of steel self-anchored cable-stayed bridges

From 1,200 to 1,400m cable-stayed bridges

will be possible!!

(through economical comparison with suspension bridges) ↓

Partially earth-anchored system

with a span of 1600m will be possible!!

(taking into account of feasibility of erection)

Page 19: Span limitation of steel self-anchored cable-stayed bridges

Concluding remarks

1) Ultimate strength is not affected by box girder depth

(3,4 & 5m dealt with in this paper) 【 ex. Lc/Hw = 470 (in case Hw = 3.0m) 】

2) Plastic behavior governs failure of the girder. 【 geometrical nonlinear effect is minor 】

3) Residual stress affect load level occurring initial yielding, however, it does not affect the strength.

4) Except for loading case-1, intermediate piers do not affect the strength.

Page 20: Span limitation of steel self-anchored cable-stayed bridges

My dream!!

Page 21: Span limitation of steel self-anchored cable-stayed bridges

From 1,200 to 1,400m cable-stayed bridges

will be possible!!

(through economical comparison with suspension bridges) ↓

Partially earth-anchored system

with a span of 1600m will be possible!!

(taking into account of feasibility of erection)

Page 22: Span limitation of steel self-anchored cable-stayed bridges

My dream!!

Page 23: Span limitation of steel self-anchored cable-stayed bridges

Thank you for your kind attention