Pub. 42004-793C GAI-TRONICS ® A HUBBELL COMPANY SP2 Fiber Remote Subset/Speaker Amplifier Station T ABLE OF C ONTENTS GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA 610-777-1374 ◼ 800-492-1212 ◼ Fax: 610-796-5954 VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS Confidentiality Notice .....................................................................................................................1 General Information .......................................................................................................................1 Product Overview ................................................................................................................................... 1 Features.................................................................................................................................................... 2 Options ..................................................................................................................................................... 2 Subsets...................................................................................................................................................... 3 Installation ......................................................................................................................................3 Important Safety Instructions................................................................................................................ 3 Enclosure Mounting and Cable Entries ................................................................................................ 4 Open the Station...................................................................................................................................... 5 Field Wiring and Configuration ............................................................................................................ 5 Station Ground ...................................................................................................................................................... 5 Termination PCBA ............................................................................................................................................... 6 Main PCBA—600-Ohm Audio I/O with Control ............................................................................................... 11 Fiber Termination Board..................................................................................................................................... 12 Remote Subset Connection ................................................................................................................................. 13 Settings and Adjustments ..............................................................................................................13 Open the Station.................................................................................................................................... 14 Main PCBA Configuration .................................................................................................................. 14 Write Protect (EEPROM) Jumper....................................................................................................................... 14 WDOG Enable (Watchdog) Jumper ................................................................................................................... 15 Boot Enable Jumper ............................................................................................................................................ 15 Reset Switch ....................................................................................................................................................... 15 Speaker and 600-ohm Audio Output Volume ..................................................................................................... 15 Receiver Volume ................................................................................................................................................ 15 Group and Station Number Selector Switches .................................................................................................... 16 Main PCBA Indicators ......................................................................................................................... 16 Power LED ......................................................................................................................................................... 16 Heartbeat LED .................................................................................................................................................... 16 Ethernet Connection LEDs ................................................................................................................................. 16 Five Configurable LEDs ..................................................................................................................................... 16 Front Cover Installation ....................................................................................................................... 16 Programming ................................................................................................................................17 Remote Subset Operation .............................................................................................................17
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Pub. 42004-793C
G A I - T R O N I C S ® A H U B B E L L C O M P A N Y
SP2 Fiber Remote Subset/Speaker
Amplifier Station
T A B L E O F C O N T E N T S
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA 610-777-1374 ◼ 800-492-1212 ◼ Fax: 610-796-5954
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Features .................................................................................................................................................... 2
Important Safety Instructions................................................................................................................ 3
Enclosure Mounting and Cable Entries ................................................................................................ 4
Open the Station ...................................................................................................................................... 5
Field Wiring and Configuration ............................................................................................................ 5 Station Ground ...................................................................................................................................................... 5 Termination PCBA ............................................................................................................................................... 6 Main PCBA—600-Ohm Audio I/O with Control ............................................................................................... 11 Fiber Termination Board ..................................................................................................................................... 12 Remote Subset Connection ................................................................................................................................. 13
Settings and Adjustments ..............................................................................................................13
Open the Station .................................................................................................................................... 14
Main PCBA Configuration .................................................................................................................. 14 Write Protect (EEPROM) Jumper ....................................................................................................................... 14 WDOG Enable (Watchdog) Jumper ................................................................................................................... 15 Boot Enable Jumper ............................................................................................................................................ 15 Reset Switch ....................................................................................................................................................... 15 Speaker and 600-ohm Audio Output Volume ..................................................................................................... 15 Receiver Volume ................................................................................................................................................ 15 Group and Station Number Selector Switches .................................................................................................... 16
Main PCBA Indicators ......................................................................................................................... 16 Power LED ......................................................................................................................................................... 16 Heartbeat LED .................................................................................................................................................... 16 Ethernet Connection LEDs ................................................................................................................................. 16 Five Configurable LEDs ..................................................................................................................................... 16
Front Cover Installation ....................................................................................................................... 16
Replacement Parts ................................................................................................................................ 19
Service .................................................................................................................................................... 19
Power ...................................................................................................................................................... 19
Maximum stations ................................................................................................................................... 4096
RTU
Output Control
Maximum load current
Output 1A (unfused) ........................................................................................................................ 8.0 A
Output 1B (fused) ............................................................................................................................ 1.6 A
Maximum in-rush current ....................................................................................................................... 15 A
Maximum voltage ............................................................................................................................. 250 V ac
Input Control
Switch type................................................................................................................. NO or NC dry contacts
8-ohm speaker ......................................................................... 30 W into 8-Ω load with −6 dBFs data signal
......................................................................................................... adjustable to 30 W; default: 4 W @ 8 Ω
16-ohm speaker ..................................................................... 15 W into 16-Ω load with −6 dBFs data signal
....................................................................................................... adjustable to 15 W; default: 2 W @ 16 Ω
Frequency response ............................................................................ 250–3,000 Hz, +0/−3 dB ref. to 1 kHz
Distortion ........................................................................................................... <1% THD @1 kHz to 24 W
<3% THD @ 1 kHz to 30 W
70V/100V Speaker Output
Maximum output .................................................................................................................................... 24 W
Nominal output voltage ......................................................................................................... 70.7 V or 100 V
Pub. 42004-793C SP2 Fiber Remote Subset/Speaker Amplifier Station Page 21 of 21
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-793C.docx 10/20
600-ohm Audio Input
Audio Level ....................................................................................................................... 1 V RMS maximum
Control type ............................................................................................................................ NO dry contact
Control cable resistance ................................................................................ 1 kΩ maximum loop resistance
600-ohm Audio Output
Frequency response ................................................................... 250–3,000 Hz, +0/−3 dB reference to 1 kHz
Distortion ..................................................................................... <1% THD @ 1 kHz to 1 V RMS into 600 Ω
Audio level ............................................................................... adjustable 100 mV RMS to1 V RMS into 600 Ω
Control type .................................................................. NO solid-state relay, maximum on resistance; 35 Ω
Control maximum load current .......................................................................................................... 100 mA
Control maximum load voltage...................................................................................................... 24 V ac/dc
NRTL certified for use in US and Canada ............................................................................. UL/CSA 60950
CE Mark
(Rev. 10/06)
WarrantyEquipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that anyGAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shallcomply with the then-current product specifications and product literature, and if applicable, shall be fitfor the purpose specified in the agreed upon quotation or proposal document. If (a) Seller’s goods proveto be defective in workmanship and/or material under normal and proper usage, or unfit for the purposespecified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above,Buyer may return such goods to GAI-Tronics nearest depot repair facility, freight prepaid, at which timethey will be repaired or replaced, at Seller’s option, without charge to Buyer. Repair or replacement shallbe Buyer’s sole and exclusive remedy. The warranty period on any repaired or replacement equipmentshall be the greater of the ninety (90) day repair warranty or one (1) year from the date the originalequipment was shipped. In no event shall GAI-Tronics warranty obligations with respect to equipmentexceed 100% of the total cost of the equipment supplied hereunder. Buyer may also be entitled to themanufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder. The applicabilityof any such third-party warranty will be determined by GAI-Tronics.
Services. Any services GAI-Tronics provides hereunder, whether directly or through subcontractors,shall be performed in accordance with the standard of care with which such services are normallyprovided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction providedany and all issues are identified prior to the demobilization of the Contractor's personnel from the worksite. Re-performance of services shall be Buyer's sole and exclusive remedy, and in no event shall GAI-Tronics warranty obligations with respect to services exceed 100% of the total cost of the servicesprovided hereunder.
Warranty Periods. Every claim by Buyer alleging a defect in the goods and/or services providedhereunder shall be deemed waived unless such claim is made in writing within the applicable warrantyperiods as set forth above. Provided, however, that if the defect complained of is latent and notdiscoverable within the above warranty periods, every claim arising on account of such latent defect shallbe deemed waived unless it is made in writing within a reasonable time after such latent defect is orshould have been discovered by Buyer.
Limitations / Exclusions. The warranties herein shall not apply to, and GAI-Tronics shall not beresponsible for, any damage to the goods or failure of the services supplied hereunder, to the extentcaused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with theequipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service theequipment. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF ANDEXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BYOPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Return PolicyIf the equipment requires service, contact your Regional Service Center for a return authorization number(RA#). Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and apurchase order number. If the equipment is under warranty, repairs or a replacement will be made inaccordance with the warranty policy set forth above. Please include a written explanation of all defects toassist our technicians in their troubleshooting efforts.
Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying theRegional Service Center closest to you.