South West Elevation PLEASE NOTE: Measured survey was carried out by client. Floor level and ground level relationship to be checked on site with levels adjusted accordingly and all agreed with client and LABC on site. A threshold drainage channel will be required where the internal floor level is the same as the external levels. A A PLEASE NOTE: Check all dimensions on site. 2350 2000 1800 2200 3000 2350 B B North West Elevation Approximate outline of neighbouring property Floor Level Floor Level Floor Level Floor Level Kitchen South East Elevation Section AA Party Wall - assess existing wall and insert lead flashing and if appropriate associated cavity trays. Make good section of wall above roof. Finish to clients specification. Roof - min. fall of Firestone EDPM flat roof is 1:80. Roof drawn at 1:50 falls to hidden gutter detail to perimeter of proposed roof. Installation and details all to manufacturers latest specification and installation instructions. Roof light - Exact location to be agreed with client. Upstand detail, installation instructions and falls all to manufacturers latest details and installation instructions. Internal Wall to Boundary - Build up structural stud partition to support roof timbers over. The exact design and details of the wall and associated reinforced floor slab or foundation all to be detailed by the Structural Engineer. This wall construction could be concrete block or structural timber stud wall as drawn. Party Wall - A small section of this wall forms the garden boundary with the neighbouring property. New cavity wall construction with small amount of insulation throughout will improve comfort levels in the garden store. Exact design and location of the boundary wall to be confirmed with neighbours and Structural Engineer consulted regarding foundation design if necessary. Lead flashing's and Cavity Trays to be installed to all roof abutments with weep vents. All installed to manufacturers latest detailed drawings and installation instructions. Parapet Walls - Create parapet walls to perimeter of garden store and take Firestone EDPM roof finish and marine plywood substrate over the head of the cavity wall finsh head of wall with a Marley Alutec powder coated aluminium coping. All installed in accordance with manufacturers latest detailed drawings, instructions and specification details. Ground level of the neighbouring property to be confirmed on site. Min. 150mm below DPC. Garden/Bike Storage South East Elevation Section BB Outline of previous extension Floor Level Floor Level ALL DRAWINGS SUBJECT TO BUILDING REGULATIONS APPROVAL TO BE READ IN CONJUNCTION WITH STRUCTURAL ENGINEER'S DRAWINGS AND DETAILED CALCULATIONS. - - - - - - - - - - - - - - - All information remains the property of the designer and may not be used for any purpose whatsoever, or reproduced through any medium without the written permission of the designer. No responsibility is accepted for unauthorised use. Do not scale off drawings, work from figured dimensions only and always verify on site. DRAWING NO. : 43 The Mount | Papcastle | Cockermouth | Cumbria | CA13 0JZ [email protected] | www.wkdesignarchitects.co.uk Carolyn Williamson 07773 329572 | Paul Kitchin 07968 094847 SCALE : DRAWN BY : DRAWING NO. : Proposed Elevations and Section A-A and B-B Alterations and Extensions to Longlands, Whinney Hill Cleator Moor for Mr and Mrs Christie 19.39.06 PK 1:100@A1 MAY 2020 Proposed 3D Model Images