Some slides from CTC... Magnet prototypes and first measurements (M.Modena et al.) Progress on TBA-Module demonstrators (G.Riddone et al.) see also BE Newsletter First simulations in order to define luminosity related observables (E. Gschwendtner et al.) M. Modena for "CLIC Project Meeting # 3; 2 Sept. 2011
9

Some slides from CTC...

Jan 16, 2016

Download

Documents

santo

Some slides from CTC. Magnet prototypes and first measurements ( M.Modena et al.) Progress on TBA-Module demonstrators ( G.Riddone et al.)  see also BE Newsletter First simulations in order to define luminosity related observables (E. Gschwendtner et al.). - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Some slides from CTC...

M. Modena for "CLIC Project Meeting # 3; 2 Sept. 2011

Some slides from CTC...

• Magnet prototypes and first measurements(M.Modena et al.)

• Progress on TBA-Module demonstrators(G.Riddone et al.) see also BE Newsletter

• First simulations in order to define luminosity related observables(E. Gschwendtner et al.)

Page 2: Some slides from CTC...

News from CLIC Magnets System (1/3)MAIN BEAM QUADRUPOLE Prototypes:Assembly and tests of MBQs Type 1 and Type 4 COMPLETED. - Magnetic measurements of Type 1 MBQ by “Single Stretched Wire” method confirm the nominal design Gradient of 200 T/m and the possibility to get higher gradient.- Measurements by “Single Vibrating Wire” method (a NEW MM development of TE/MSC-MM) provided a first rough evaluation of the Field Quality that, as expected, is not acceptable (due to the poor quality in quadrant machining and grinding by the Contractor). (Special Thanks to Carlo Petrone for the Magnetic Measurements)

M. Modena for "CLIC Project Meeting # 3; 2 Sept. 2011

Both magnets are now available for Stability Tests and CLIC Lab Test Program

Page 3: Some slides from CTC...

News from CLIC Magnets System (2/3)QDO SHORT Prototype:- Assembly and tests of core part completed; Coils under manufacturing (3/4 ready). - Magnetic Measurements by “Single Stretched Wire” method confirm the design gradients of ~ 150 and 200 T/m in the configuration with only permanent magnet blocks- Measurements by “Single Vibrating Wire” method provided a first rough evaluation of the Field Quality in the range of what expected and required.

M. Modena for "CLIC Project Meeting # 3; 2 Sept. 2011

PM material type

Integrated gradient ∫Gdl [T]

MSRD Calculated

VACOMAX 225HR (Sm2Co17)

15.4 15.6

VACODYM 655HR (Nd2Fe14B) 20.3 21.2

Page 4: Some slides from CTC...

News from CLIC Magnets System (3/3)

More precise measurement of the Field Quality will be provide by the NEW rotating coils system (Ø of 7.7 mm) under commissioning in these days (Special Thanks to Olaf Dunkel).

M. Modena for "CLIC Project Meeting # 3; 2 Sept. 2011

Provisional

results!

Page 5: Some slides from CTC...

G. Riddone on behalf of the CMWG 5

Two-beam module

9/1/2011

- TS for “integrated” girders in CLEX in progress, comments from WG members are being implemented (contacted several firms which showed interest): CfT by end of Sept 2011

- DBQ and BPM mock-up, including vacuum chambers, received at CERN installation will start after pre-alignment tests will be finished

- components for first 2 RF units at CERN under cleaning and brazing

- equipment for “thermal” tests available at CERN

Page 6: Some slides from CTC...

Geometry of the Luminosity Monitoring

Armen Apyan CLIC PCLD-WG Meeting - 25.08.11 6

3×80 cm thick Concrete blocks

~12cm

Separation of disrupted beam and beamstrahlung photons ~ 12cm

Converter - water in main dump muons detector behind the dump

Page 7: Some slides from CTC...

Spatial Distribution of Muons after Beam Dump (No Offset)

Armen Apyan CLIC PCLD-WG Meeting - 25.08.11 7

Page 8: Some slides from CTC...

Luminosity and Backgrounds Beam-Beam Offset

Armen Apyan 8CLIC PCLD-WG Meeting - 25.08.11

B. Dalena and D. Schulte

Page 9: Some slides from CTC...

Spatial Distribution of Muons after Beam Dump (Vertical Offset)

Armen Apyan CLIC PCLD-WG Meeting - 25.08.11 9

-30 nm +30Non Offset