Create more for you Kudom Electronics Technology www.kudom-elec.com Rev.2.5,6-25-2018 KSMA*** D Series Single Phase AC Output Product Description Ordering Information KSM Series Load Type A: AC Load Load Voltage 240: 240VAC DC Control Load Current 1: 1Amp 2: 2Amp Control Voltage 5: 5VDC 12: 12VDC 24: 24VDC Blank: without Socket D: with Socket KSM A 240 D 1 -5 D Switching Mode Blank: Zero Crossing R: Random-on R General Specifications Control Voltage Range1Input Specifications (Ta=25) -5 -12 -24 -5 -12 -24 4-6VDC 9.6-14.4VDC 19.2-28.8VDC 4VDC 9.6VDC 19.2VDC Must Turn-On Voltage2Must Turn-Off Voltage Maximum Input Current Product Description TRIAC Output Optical Isolation Dielectric Strength: 2500Vrms Load Current: 1A, 2A PCB or Socket Mounted Load Voltage: 240VAC RoHS Compliant Output Specifications (Ta=25) 1A 2A Zero Crossing Random-on 1A 2A 0.1 - 1A 0.1 - 2A 10ms 1ms 10ms 30A 80A Load Voltage Range Maximum Transient Overvoltage Load Current Range Maximum Turn-On Time Maximum Turn-Off Time 1VDC 25mA 1.5mA 1.5Vrms 200V/μs 24-280VAC 600Vpk Maximum Surge Current (@10 ms) Maximum Off-State Leakage Current @ Rated Load Voltage Maximum On-State Voltage Drop @ Rated Current Minimum Off-State dv/dt @ Maximum Rated Voltage (1) For KSMD with control voltage at 12V, 24V equipped with the socket, the control voltage limit should be increased by 1.4V, for example, for KSMD24D4-12D, please ensure that the control voltage is 9.6V+1.4V=11V Min. (2) For KSMDXXDX-5, with socket or without socket the control voltage limit is still 4V, no need to add 1.4V.
4

Solid State Relay KSMA Series Single Phase AC OutputSolid State Relay KSMA Series Single Phase AC Output Product Description Product Selection TTL,COMS Drive Compatible Optoelectronic

Mar 10, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Solid State Relay KSMA Series Single Phase AC OutputSolid State Relay KSMA Series Single Phase AC Output Product Description Product Selection TTL,COMS Drive Compatible Optoelectronic

Create more for you

Kudom Electronics Technologywww.kudom-elec.comRev.2.5,6-25-2018

KSMA*** D Series Single Phase AC Output

Product Description

Ordering Information

KSM Series Load TypeA: AC Load

Load Voltage240: 240VAC

DC Control Load Current1: 1Amp 2: 2Amp

Control Voltage5: 5VDC12: 12VDC24: 24VDC

Blank:without SocketD: with Socket

KSM A 240 D 1 -5 D

Switching ModeBlank: Zero Crossing R: Random-on

R

General Specifications

Control Voltage Range(1)

Input Specifications (Ta=25℃)-5

-12

-24

-5

-12

-24

4-6VDC

9.6-14.4VDC

19.2-28.8VDC

4VDC

9.6VDC

19.2VDC

Must Turn-On Voltage(2)

Must Turn-Off Voltage

Maximum Input Current

Product Description

TRIAC Output Optical Isolation Dielectric Strength: 2500Vrms Load Current: 1A, 2APCB or Socket MountedLoad Voltage: 240VACRoHS Compliant

Output Specifications (Ta=25℃)

1A

2A

Zero Crossing

Random-on

1A

2A

0.1 - 1A

0.1 - 2A

10ms

1ms

10ms

30A

80A

Load Voltage Range

Maximum Transient Overvoltage

Load Current Range

Maximum Turn-On Time

Maximum Turn-Off Time

1VDC

25mA

1.5mA

1.5Vrms

200V/μs

24-280VAC

600Vpk

Maximum Surge Current (@10 ms)

Maximum Off-State Leakage Current @ Rated Load Voltage

Maximum On-State Voltage Drop @ Rated Current

Minimum Off-State dv/dt @ Maximum Rated Voltage

(1) For KSMD with control voltage at 12V, 24V equipped with the socket, the control voltage limit should be increased

by 1.4V, for example, for KSMD24D4-12D, please ensure that the control voltage is 9.6V+1.4V=11V Min.

(2) For KSMDXXDX-5, with socket or without socket the control voltage limit is still 4V, no need to add 1.4V.

Page 2: Solid State Relay KSMA Series Single Phase AC OutputSolid State Relay KSMA Series Single Phase AC Output Product Description Product Selection TTL,COMS Drive Compatible Optoelectronic

Rev.2.5,6-25-2018

Create more for you

Kudom Electronics Technologywww.kudom-elec.com

KSMA*** D Series Single Phase AC Output

General Specifications

Wiring Diagram

General Specifications (Ta=25℃)

without SocketD: with Socket

2500Vrms

1000MΩ

-30℃ ~ +80℃-30℃ ~ +100℃

Dielectric Strength (50/60Hz)

Minimum Insulation Resistance (@500VDC)

Ambient Temperature Range

Storage Temperature Range

Weight (Typical)

Suitable for high density PCB mounting, PLC control applications, and etc.

Outline Dimensions

SSR

SSR

Applications

Load

4g

30g

81±0

.3

96.5±0.5

6.2±0

.2

34.5 +0.20

with Socket

Page 3: Solid State Relay KSMA Series Single Phase AC OutputSolid State Relay KSMA Series Single Phase AC Output Product Description Product Selection TTL,COMS Drive Compatible Optoelectronic

Rev.2.5,6-25-2018

Create more for you

Kudom Electronics Technologywww.kudom-elec.com

性能曲线Thermal Derating Curve

KSMA*** D Series Single Phase AC Output

General Notes

Thermal Derating Curve

Agency Approvals (Certification)

Load

Cur

rent

(A)

Ambient Temperature (℃)

00 10 20-30 -20 -10 30 40 50 60 70 80

0.5

11A

Load

Cur

rent

(A)

Ambient Temperature (℃)

00 10 20-30 -20 -10 30 40 50 60 70 80

1

2

0.5

1.5

2A

1. Soldering must be finished within 10 seconds at 260℃,or finished within 5 seconds at 350℃. Otherwise it may cause damage to the

relay.

2. When connecting wiring to SSR please ensure screws are torqued down properly 4.43/0.5 in lb/N·m

3. When ambient temperature is above 25℃, the maximum load current decreases. See thermal derating curve.

A1-

A2+

14(-/~)

11(+/~)

INPUT

DC+ DC-

Load

AC AC

OUTPUT

A1(-/+)

A2(+/-)

14(-/~)

11(+/~)

INPUT

Load

AC ACDC DC

OUTPUT

KSMAXXX-5D KSMAXXX-(12、24)D

Wiring Diagram (with Socket)

Page 4: Solid State Relay KSMA Series Single Phase AC OutputSolid State Relay KSMA Series Single Phase AC Output Product Description Product Selection TTL,COMS Drive Compatible Optoelectronic

Trademark Change Notification

Due to the company’s strategic development needs, Xiamen Kudom Electronics Technology

Co., Ltd will be acquired by i-Autoc (Xiamen) Investment Co., Ltd from 1st of July 2019. After

the acquisition, all the products by Xiamen Kudom Electronics Technology Co., will no longer

use Kudom trademark, but use i-Autoc trademark. The details of the change are as follows.

The original trademark will be changed to . The original trademark

will still be used until 30th June 2019.

This is a change to the trademark only, the Company Name, Manufacturing Location,

Management Team, Product Part Numbers and Safety Approval Licence Numbers (cUL, TUV,

CCC, S-mark Etc) are to remain the same.