Project: Location: Cat.No: Type: Lamps: Qty: Notes: SoleCity-ULLC100-Spec 12/20 page 1 of 5 Urban SoleCity ULLC100 LED Light Column Lumec SoleCity family, going beyond decorative functional outdoor lighting to help you create a unique, stunning and harmonious look for any public space. Ordering guide example: ULLC100-80W48LED3K-G2-LEV3-120-DMG-18-BKTX Series ULLC100 LED Module Board Gen G2 Optical System Volts Driver Options Height Luminaire Options Finish ULLC100 SoleCity Light Column 3000K 35W32LED3K 55W32LED3K 55W48LED3K 80W48LED3K 70W64LED3K 110W64LED3K 4000K 35W32LED4K 55W32LED4K 55W48LED4K 80W48LED4K 70W64LED4K 110W64LED4K G2 LEV3 Type III (ASYM) LEV5 1 Type V (SYM) 120 208 240 277 347 480 UNV AST 2 Pre-set driver for progressive start-up CDMGE25 2 8 hrs. 25% reduction CDMGE50 2 8 hrs. 50% reduction CDMGE75 2 8 hrs. 75% reduction CDMGM25 2 6 hrs. 25% reduction CDMGM50 2 6 hrs. 50% reduction CDMGM75 2 6 hrs. 75% reduction CDMGS25 2 4 hrs. 25% reduction CDMGS50 2 4 hrs. 50% reduction CDMGS75 2 4 hrs. 75% reduction CDMGP 2 Dimming level determined by user CLO 2 Pre-set driver to manage lumen depreciation DALI 2 Pre-set, compatible with the DALI control system DMG 0-10V OTL 2 Pre-set driver to signal end of life of the lamp 10 11 12 13 14 15 16 17 18 19 20 CS Clear Satin Lens OVR 3 PH7 4 PH8 PH9 PHXL PWFP1 RCD 5 Receptacle for twist-lock photocell or shorting cap, 5-pin RCD7 5 Receptacle for twist-lock photocell or shorting cap, 7-pin RWP1 SSP UD VPA Textured BE2TX Midnight Blue BE6TX Ocean Blue BE8TX Royal Blue BG2TX Sandstone BKTX Black BRTX Bronze GN4TX Blue Green GN6TX Forest Green GN8TX Dark Forest Green GNTX Green GY3TX Medium Grey RD2TX Burgundy RD4TX Scarlet WHTX White Non-Textured GR Gray Sandtex NP Natural Aluminum TG Hammertone Gold 1. Available with 64LED only (lights on both sides). 2. Not available 347-480 volt. 3. CDMG Dynadimmer need to be selected to have OVR available. 4. UNV not available with PH7, need to select specific voltage: 120,208,240 or 277 volt. 5. Use of photoelectric cell or shorting cap is required to ensure proper illumination.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Project:
Location:
Cat.No:
Type:
Lamps: Qty:
Notes:
SoleCity-ULLC100-Spec 12/20 page 1 of 5
Urban
SoleCity
ULLC100 LED Light Column
Lumec SoleCity family, going beyond decorative functional outdoor lighting to help you create a unique, stunning and harmonious look for any public space.
DALI 2 Pre-set, compatible with the DALI control system
DMG 0-10V
OTL 2 Pre-set driver to signal end of life of the lamp
10
11
12
13
14
15
16
17
18
19
20
CS Clear Satin Lens
OVR 3
PH7 4
PH8
PH9
PHXL
PWFP1
RCD 5
Receptacle for twist-lock photocell or shorting cap, 5-pin
RCD7 5
Receptacle for twist-lock photocell or shorting cap, 7-pin
RWP1
SSP
UD
VPA
Textured
BE2TX Midnight Blue
BE6TX Ocean Blue
BE8TX Royal Blue
BG2TX Sandstone
BKTX Black
BRTX Bronze
GN4TX Blue Green
GN6TX Forest Green
GN8TX Dark Forest Green
GNTX Green
GY3TX Medium Grey
RD2TX Burgundy
RD4TX Scarlet
WHTX White
Non-Textured
GR Gray Sandtex
NP Natural Aluminum
TG Hammertone Gold
1. Available with 64LED only (lights on both sides). 2. Not available 347-480 volt.
3. CDMG Dynadimmer need to be selected to have OVR available.4. UNV not available with PH7, need to select specific voltage: 120,208,240 or 277 volt.5. Use of photoelectric cell or shorting cap is required to ensure proper illumination.
Values from photometric tests performed in accordance with IESNA LM-79 and are representative of the configurations shown. Actual performance may vary due to installation and environmental variables, LED and driver tolerances, and field measurement considerations. It is highly recommended to confirm performance with a photometric layout. Note: Some data may be scaled based on tests of similar (but not identical) luminaires. Contact factory for configurations not shown.
Dimensions Anchor Plate
Semelle d’ancrage
Cercle de boulonnage : 10 1/2" ø (267 mm)C.B. possible : 9 1/2" à 11 1/2" (267 mm à 292 mm)
10 1
/4 p
o (2
60 m
m)
Bolt circle : 10 1/2" ø (267 mm)B.C. allowed : 9 1/2" to 11 1/2" (267 mm to 292 mm)
10 1
/4 "
(260
mm
)
Mounting detailsComes with 4 steel anchor bolts, 3/4" x 20" (19 ø mm X 508 mm), 4 nuts and 4 washers.Important: Do not obstruct space between anchor plate and concrete base
Détails d’ancrageLivré avec 4 boulons d’ancrage en acier, 3/4" x 20" (19 mm ø X 508 mm),4 écrous et 4 rondelles.Important : Ne pas obstruer l’espace entre la semelle et la base de béton.
Anchor Plate
Semelle d’ancrage
Cercle de boulonnage : 10 1/2" ø (267 mm)C.B. possible : 9 1/2" à 11 1/2" (267 mm à 292 mm)
10 1
/4 p
o (2
60 m
m)
Bolt circle : 10 1/2" ø (267 mm)B.C. allowed : 9 1/2" to 11 1/2" (267 mm to 292 mm)
10 1
/4 "
(260
mm
)
Mounting detailsComes with 4 steel anchor bolts, 3/4" x 20" (19 ø mm X 508 mm), 4 nuts and 4 washers.Important: Do not obstruct space between anchor plate and concrete base
Détails d’ancrageLivré avec 4 boulons d’ancrage en acier, 3/4" x 20" (19 mm ø X 508 mm),4 écrous et 4 rondelles.Important : Ne pas obstruer l’espace entre la semelle et la base de béton.
Lights on both sides when LEV5 option is ordered
SoleCity-ULLC100-Spec 12/20 page 3 of 5
ULLC100 LED Light ColumnUrban Luminaire
Values from photometric tests performed in accordance with IESNA LM-79 and are representative of the configurations shown. Actual performance may vary due to installation and environmental variables, LED and driver tolerances, and field measurement considerations. It is highly recommended to confirm performance with a photometric layout. Note: Some data may be scaled based on tests of similar (but not identical) luminaires. Contact factory for configurations not shown.
HousingPole Shaft: Made from a 7 1/8" (181mm) wide by 5 3/8" (137mm) deep elliptical exclusive shape, extruded 6063 T6 aluminum tubing, welded to both the bottom and top of the anchor plate.
End Cap: Made of cast A356 Aluminum alloy 0.188 (4.8mm) minimum thickness, mechanically assembled to the housing.
Maintenance Opening: The pole shall have a 3 1/4" x 8" (83mm x 203mm) maintenance opening centered at 11" (279mm) from the bottom of the anchor plate, complete with a weatherproof aluminum cover and a factory assembled copper ground lug.
Base Cover: Two piece oval shape base cover made from cast 356 aluminum, mechanically fastened with two stainless steel screws discreetly concealed.
Light engineLEDgine composed of 5 main components: Heat Sink / Lens / LED lamp / Driver / Optical System. Electrical components are RoHS compliant.
LED engineComposed of high-performance white LEDs. Color temperature as per ANSI/NEMA bin Neutral White, 4000 Kelvin nominal (3985K +/-.275K or 3710K to 4260K) or Warm white, 3000 Kelvin nominal (3045K +/- 175K or 2870K to 3220K), CRI 70 Min. 75 Typical.
LensLens: Made of clear polycarbonate curved lens, permanently assembled and sealed onto the lower part of the heat sink
Lens: (CS) Made of satin clear polycarbonate curved lens, permanently assembled and sealed onto the lower part of the heat sink.
Heat sinkMade of cast aluminum optimizing the LEDs efficiency and life. Product does not use any cooling device with moving parts (only passive cooling device).
Optical systemComposed of high performance optical grade PMMA acrylic refractor lenses to achieve desired distribution optimized to get maximum spacing, target lumens and a superior lighting uniformity. Optical system is rated IP66. Performance shall be tested per LM 63, LM 79 and TM 15 (IESNA) certifying its photometric performance. Street side indicated.
LEV3: Type III (ASYM) LEV5: Type V (SYM)
DriverDriver comes standard with dimming compatible 0-10V. High power factor of 90% minimum. Electronic driver, operating range 50/60 Hz. Auto adjusting universal voltage input from 120 to 277 or 347 to 480 VAC rated for both application line to line or line to neutral, Class I, THD of 20% max. Maximum ambient operating temperature from 40°F (40°C) to 130°F (55°C). Certified in compliance to UL1310 cULus requirement. Dry and damp location. Assembled on a unitized removable tray with Tyco quick disconnect plug resisting to 221°F (105°C). The current supplying the LEDs will be reduced by the driver if the driver experiences internal overheating as a protection to the LEDs and the electrical components. Output is protected from short circuits, voltage overload and current overload. Automatic recovery after correction. Standard built in driver surge protection of 2.5kV (min).
Surge protectorSurge protector tested in accordance with ANSI/IEEE C62.45 per ANSI/IEEE C62.41.2 Scenario I Category C High Exposure 10kV/10kA waveforms for Line Ground, Line Neutral and Neutral Ground, and in accordance with U.S. DOE (Department of Energy) MSSLC (Municipal Solid State Street Lighting Consortium) model specification for LED roadway luminaires electrical immunity requirements for High Test Level 10kV / 10kA.
Driver optionsAST: Pre-set driver for progressive start-up of the LED module(s) to optimize energy management and enhance visual comfort at start-up.
CLO: Pre-set driver to manage the lumen depreciation by adjusting the power given to the LEDs offering the same lighting intensity during the entire lifespan of the LED module.
OTL: Pre-set driver to signal end of life of the LED module(s) for better fixture management.
DMG: Dimmable driver 0-10V.
CDMG: Dynadimmer standard dimming functionalities including pre-programmed scenarios to suit many applications and needs from safety to maximum energy savings.
DALI: Pre-set driver compatible with the DALIcontrol system.
Ordering Code
Dimming
Scenario Time Level
CDMGS25 Safety 4 hours 25% power
CDMGS50 Safety 4 hours 50% power
CDMGS75 Safety 4 hours 75% power
CDMGM25 Median 6 hours 25% power
CDMGM50 Median 6 hours 50% power
CDMGM75 Median 6 hours 75% power
CDMGE25 Economy 8 hours 25% power
CDMGE50 Economy 8 hours 50% power
CDMGE75 Economy 8 hours 75% power
ULM Luminaire Options CS: Clear Satin Lens
OVR: Dynadimmer override function offering the possibility to go back to full power at any time via an electrical signal of 120VAC to 277VAC from a motion sensor, a switch, a relay or else.
PH7: Photoelectric cell
PH8: Twist-lock Photoelectric Cell
PH9: Shorting cap
PHXL: Twist-lock Photoelectric Cell, extended life
PWFP1: Painted Wood Finish Panel
RC: Receptacle for twist-lock photocell or shorting cap, 3-pin
RCD: Receptacle for twist-lock photocell or shorting cap, 5-pin
RCD7: Receptacle for twist-lock photocell or shorting cap, 7-pin
RWP1: Real Wood Panel Ipe Type
SSP: Stainless Steel Panel
UD: Uplight deflector
VPA: Vandal proof screws
FinishIn accordance with the AAMA 2603 standard. Application of polyester powder coat paint (4 mils/100 microns) with +/- 1 mils/24 microns of tolerance. The Thermosetting resins provides a discoloration resistant finish in accordance with the ASTM D2244 standard, as well as luster retention in keeping with the ASTM D523 standard and humidity proof in accordance with the ASTM D2247 standard. The surface treatment achieves a minimum of 2000 hours for salt spray resistant finish in accordance with testing performed and per ASTM B117 standard.
Textured Finish Options: BE2TX: Midnight Blue BE6TX: Ocean Blue BE8TX: Royal Blue BG2TX: Sandstone BKTX: Black BRTX: Bronze GN4TX: Blue Green GN6TX: Forest Green GN8TX: Dark Forest Green GNTX: Green GY3TX: Medium Grey RD2TX: Burgundy RD4TX: Scarlet WHTX: White
Luminaire useful lifeRefer to IES files for energy consumption and delivered lumens for each option. Based on ISTMT in situ thermal testing in accordance with UL1598 and UL8750, using LM-80 data from LED manufacturers and engineering prediction methods, the luminaire useful life is expected to reach 100,000+ hours with >L70 lumen maintenance @ 25°C. Luminaire Useful Life accounts for LED lumen maintenance AND all of these additional factors including: LED life, driver life, PCB substrate, solder joints, on/off cycles, burning hours and corrosion. Entire luminaire is rated for operation in ambient temperature of -40°C / -40°F up to +35°C / +95°F.
HardwareAll exposed screws shall be complete with Ceramic primer-seal base coat to reduce seizing of the parts and offers a high resistance to corrosion. All seals and sealing devices are made and/or lined with EPDM and/or silicone and/or rubber.
Quality controlManufactured to ISO 9001 2008 standards and ISO 14001-2004 International Quality Standards Certification.
LED products (manufacturing standard)
The electronic components sensitive to electrostatic discharge (ESD) such as light emitting diodes (LEDs) are assembled in compliance with IEC61340 5 1 and ANSI/ ESD S20.20 standards so as to eliminate ESD events that could decrease the useful life of the product.
Certifications and Compliance
CSA, cULus Listed for Canada and USA. Luminaires are DesignLights Consortium qualified
16'-0
" (48
77m
m)
18'-0
" (54
86m
m)
10'-0
" (30
48m
m)
20'-0
" (60
96m
m)
12'-0
" (36
58m
m)
Assembly
LED Performance
Predicted lumen depreciation data1
Ambient Temperature (°C) Driver mA
Calculated L70 hours1,2 L70 per TM-212,3
Lumen Maintenance % @ 60,000 hours
25°C 530 mA >100,000 >60,000 88%1. Predicted performance derived from LED manufacturer’s data and engineering design estimates,
based on IESNA LM-80 methodology. Actual experience may vary due to field application conditions.2. L70 is the predicted time when LED performance depreciates to 70% of initial lumen output. 3. Calculated per IESNA TM21-11. Published L70 hours limited to 6 times actual LED test hours.