Production State-Of-The-Art manufacturing facility in Pune. With experienced professional engineers. Quality & Professional service providers (24x7). Professional & Technical, Marketing, Sales, After Sales. Research & Development Services Sales & Marketing Office KSolare Indian manufacturing company provides complete solution in Grid-Tie inverters. [0.5KW-60KW] ENERGY SOLUTION FOR PV SYSTEM “Technology... Connects Human With Nature” Solare Solare Solare Grid Tie Inverter Mfg. In India
8
Embed
Solare · 2017-09-20 · KSolare Indian manufacturing company provides complete solution in Grid-Tie inverters. [0.5KW-60KW] ... Battery Bank AC Load Solar Panel Utility DC DC AC
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ProductionState-Of-The-Art manufacturing facility in Pune.
With experienced professional engineers.
Quality & Professional service providers (24x7).
Professional & Technical, Marketing, Sales, After Sales.
Research & Development
Services
Sales & Marketing Office
KSolare Indian manufacturing company provides complete solution in Grid-Tie inverters. [0.5KW-60KW]
ENERGY SOLUTION FOR PV SYSTEM
“Technology... Connects Human With Nature”
SolareSolareSolareGrid Tie Inverter Mfg. In India
“KSolare builds Technology which connects human with nature.”
Today’s world energy consumption is exponentially increasing anddepleting the natural energy reserves like:- Oil, Gas Coal.
KSolare brings innovative technology by integrating natural resourcesto generate electricity.
Vision:- To build ‘Green India’ through harvesting solar energy andto provide 24x7x365 days uninterrupted electricity.
Mission:- To create extra value for the organization by high techinnovative designs in manufacturing renewable product.
RH/Max. Altitude 0% to 98%. No Condensation / <2000 without power derating
Display LED LED With Graphical Display
Standard Warranty 5 Years
KMT 0.5KW - 2KW
Suitable for small rooftop application.(0.5kw-3kw)
Easy design with Plug & Play installation.IP 21 Indoor App proof protection.High efficiencies of 94% ~ 95.2%.Standby power consumption <150mW.Integrated over voltage and instantaneousanti-islanding.
LoadMeter
500W
R Phase Y PhaseB Phase
1000W
2000W
Power Grid
SolareSolareSolarewww.ksolare.com
KSS 1KW - 6KW
Extremely high conversion efficiencies up-to 98.7%.TEXAS Quad core Dual DSP based digital processor.Multi-string technology with extra wide MPPT range.Built-in WiFi / GPRS with real time PV Monitoring.Innovative weak-light power generation technology.User defined Grid Parameters Controller (V / F / W).Next generation strong MPPT used.
MODEL NO CAPACITY KSS-1KW KSS-1.5KW KSS-2KW KSS-3KW KSS-4KW KSS-5KW KSS-6KW
Input (DC)
Max. DC Power (W) 1200 1700 2400 3500 4500 5500 6500
Max. DC Voltage (Vdc) 450 500 550
MPPT Tracking Voltage 70-450 100-500
Number of MPPT Tracker /Strings Per MPPT 1 2
Strings Per MPPT trackers 1/1 2/1
Min. Start-up/Shutdown Voltage(V) 100 / 150 120 / 150
Safety DC Reverse -Polarity & SC Protection, DC/AC side Varistor (Thermally Protected),Grid monitoring & Anti Islanding, Transformer-less Isolation.
Protection Class 1 (According to IEC62103)
Over Voltage Category PVII / Mains II(According to IEC62109-1)
Safety Standard IEC 62109-1&2,IEC 62116
EMC Standard IEC 61000-6-1/2/3/4
Environment Protection IEC 60068-2-1/2/14/15
Ingress Protection IP 65(Accordance to IEC 60529)
Physical Parameters
Dimensions (LxBxH) mm 395x355x170 399x565x172 430x600x220 530x688x357 958x636x260
Weight(kg) 25 27 27 30 32 53 55 60 65
General Data
Operating Temperature -25 to 60 degree
Night Con.(W) / Noise Level <0.2 / <25dB
Heat Dissipation Natural Convection Natural Convection + Fan
RH/Max. Altitude 0% to 98%. No Condensation / <2000 without power derating
Display LED with Graphical Mimic Display
Communication Interface RS 485 / WiFi
Standard Warranty 5 Years
Top high quality AL profile to reduce & maintain temperature.All-whether proof ...IP 65, All IEC Standards for Safety.Fan less technology, natural convection & engineering profile heat sink design.Super capacitor for longer life with Watchdog circuitry for Redundancy.Inbuilt ELC and SPD Protection in AC / DC power side.Full Graphic Mimic LCD with Backlight.Infineon make IGBT with 20% more power rating than others with HighSwitching Frequency.
Recommended where there are less power failure & usages are at night time.Energy produced by the PV system is used to optimize self-consumption. The excess energy is usedto recharge the batteries. When the batteries are fully charged and the system is already meeting self-consumption requirements, excess energy is fed into the power grid.
Automatic start and shut off- starts automatically.Sensor-less dry run protection (automatic switch-off and switch on)..Hi Degree of protection against Phase imbalance & output short circuit protection etc.Visual indication with LCD for all the parameters with of faults.Can sync with Grid AC input or Genset AC input with IP65 enclosure.GPRS connectivity via mobile to start/stop remotely & to monitor the status of water pumps remotely.
Used a power backup & Grid Export.
Programmable supply priority for PV, Battery & Grid.
Battery Management System to protect & enhancethe battery life.
Highly Intelligent 2nd Generation technology.
Reduces the entire energy bill.
KSolare provide 27x7x365 days remote monitoring for theperformance of the project.
Inverter
Battery Bank
AC Load
Solar Panel
Utility
DC
DC
AC
AC
Import / Export
Bi-directional Hybrid
SolareSolareSolarewww.ksolare.com
24x7 Web Monitoring
The KSolare monitoring System is based on , cloud computing, and other new technologies for PVsystem, from the various device ( RS-485,wifi,GPRS,RF) the data is transmitted to remote serviceplatform for data storage & analysis which is displayed in various visual & graphical formats onWeb Apps & big screen display also for bigger platform it can be customized as per customer request.
EMI / RFI Protection of AC / DC side.Each & every product undergoes regress heat run test for min. 12hrs.Our inverter does not require AJB & MJB.Few products are with 130% overload capacity.Power factor connection for multiple string inverter.In-house product training for installation & commissioning.Post warranty support with circuit level & component level repairing facility.Tailor made solution.