PUMP PUMP PLUS OPTIONAL HEATING OR ACCESSORY EQUIPMENT RETURN TO POOL FROM POOL LORENTZ P S600 BADU PUMP MOUNT DETAILS SHOWN ON THIS PLAN. INSTALL PER OEM INSTRUCTIONS PV CONTROLLER LIGHTNING ARRESTOR OPTIONAL + + + + 3 MODULS IN 1 ARRAY PV MODULE PV MODULE PV MODULE J BOX ATTACH TO ROOF FRAMING MEMBER WITH 2 LAG BOLTS EACH STANDOFF 4'-0" 4'-0" 3'-0" PZ2 PZ2 PZ3 PZ1 DN 4/1° SOUTH EAVE HIP RIDGE 1 STORY RESIDENCE 3 PV MODULES 4/12 TILE ROOF SHEET NO: PUBLISHED: SHEET NAME: DRAWN: CHECKED: SB AG ENLARGED VIEWING & HYPERLINKS: PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS. ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT: WWW.GEZELMANPE.COM/PV/0318P.BS_KienPoolPump_Pompano_FL.dwg REVISIONS: 03 SCALE: NTS SAMPLE INSTALLATION PHOTOS I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT. ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE. CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL. CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWN HERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THE ARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADING OF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION! COPY RIGHT & INTELLECTUAL PROPERTY NOTICE • THIS PLAN SET IS COPY RIGHT PROTECTED AND CONTAINS INTELLECTUAL PROPERTY WHICH BELONGS TO ALLEN GEZELMAN PE. • ACCESS IS GIVEN TO THE INFORMATION HEREON SOLELY FOR THE PURPOSE OF COMPLETION OF THE PROJECT FOR WHICH IT IS INTENDED. • NO OTHER USE MAY BE MADE OF THE INFORMATION, DRAWINGS, OR IDEAS HEREON WITHOUT THE EXPRESS , WRITTEN, PERMISSION OF ALLEN GEZELMAN PE ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 OR PROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF THIS PLAN IS ONLINE FOR REVIEW @ WWW.GEZELMANPE.COM/PV/0318P.BS_KIENPOOLPUMP_POMPANO_FL.PDF CONTACT DESIGN TEAM @ www.GezelmanPE.com ALLEN GEZELMAN 16502 HANNA RD. LUTZ, FLORIDA 33549 PH. 813 650 7246 FX. 866 397 9050 Allen@Gezelman PE.COM www.GezelmanPE.com I CERTIFY THAT THIS DESIGN & SPECIFICATIONS MEET THE CURRENT FLORIDA BUILDING CODE INSTALLATION OF A ROOF MOUNT PHOTOVOLTAIC POOL PUMP SYSTEM THE KIEN RESIDENCE VULT 170_MPH, VASD 131.7 MPH EXPOSURE: C, RISK CATEGORY: II, PZ2 WIDTH 3-FT WORSE CASE WIND FORCES; UPLIFT, NEGATIVE, PSF, PZ1-32, PZ2-54.5, PZ3-83.4_PSF CODE VERIFY MODULE# SHARP ND 240 QCJ, FSEC: #SH11-NT90-0616 DESIGNED PER: ASCE 7-10, FBC 2010 WIND 01 SCALE: 1/4" = 1'-0" ROOF LAYOUT PLAN AHJ: BROWARD COUNTY, PARCEL ID# 4843 30 21 0940 SITUS: 1211 NE 28 AVENUE, POMPANO BEACH, FL STRUCTURAL LOAD FROM EQUIP < 4PSF 10.21.2013 OWNER OF RECORD: 1211 NE 28 AVE POMPANO BEACH FL 33062-3822 KIEN,F MICHAEL PV POOL PUMP STRUCTURAL INSTALLATION NOTES -ELECTRICAL DESIGN BY CONTRACTOR. INSTALLATION SHALL BE MADE USING UNIRAC STANDARD RAILS INSTALLED PER OEM INSTRUCTIONS HTTP://WWW.UNIRAC.COM/PDF/II227.PDF AND DRAWING FIGURES THIS PLAN SHEET. RAILS SHALL BE CONNECTED WITH L-FEET ON TOP OF STAND-OFFS SOLIDLY ATTACHED INTO ROOF FRAMING ON 4-FT CENTERS USING MINIMUM 5/16-INCH DIAMETER CRS (CORROSION RESISTANT STEEL) LAGS OF SUFFICIENT LENGTH TO ACHIEVE MINIMUM OF 3-INCH EMBEDMENT. A GENEROUS PUDDLE OF FLORIDA PCA ROOF SEALANT BETWEEN STANDOFF AND ROOF COVERING IS ADEQUATE WATERPROOFING. CONTRACTOR IS FREE TO CHOOSE ALTERNATE METHOD ACCEPTABLE TO AHJ (AUTHORITY HAVING JURISDICTION AKA BUILDING DEPARTMENT). EACH PV MODULE SHALL BE SUPPORTED BY TWO RAILS AND SHALL ATTACH THERETO AT CROSSING POINTS (4-PER MODULE). ADJACENT MODULES MAY SHARE ATTACHMENTS TO RAIL . 04 SCALE: NTS PV MODULE DATA SHEET 09 SCALE: NTS FLAT OR BARREL TILE ATTACHMENT - MOUNTING SYSTEM- UNIRAC.COM 10 SCALE: NTS , THESE PICTURES ARE TYPICALL INSTALLATIONS SAMPLE INSTALLATION PHOTOS DETAILS MAY VARY - CURRENT OEM INSTRUCTIONS PREVAIL HTTP://WWW.UNIRAC.COM/RESIDENTIAL/RESIDENTIAL-PRODUCTS/SOLAR-MOUNT-RESIDENTIAL UNIRAC CODE COMPLIANT LETTER - FLORIDA: THIS PV POOL PUMP PLAN WILL PROVIDE ADEQUATE PUMPING CAPACITY TO SATISFY THE REQUIREMENTS OF A SOLAR POOL HEATER FOR A TYPICAL RESIDENTIAL POOL IN CONJUNCTION WITH MY PLANS http://www.cadvice.us/sw/AS.2.2.PH.pdf & http://www.cadvice.us/sw/AS.2.2.PH_FSM.pdf BIG POOLS, POOLS WITH SPECIAL CLEANING APPARATUS, POOLS WITH HIGH BACK-PRESSURE FILTRATION, AND/OR NON-STANDARD HYDRAULICS WILL REQUIRE SITE-SPECIFIC ENGINEERING. CONTRACTOR & OTHERS ARE DIRECTED TO OEM PERFORMANCE DATA http://www.lorentz.de/pdf/lorentz_ps600_badutop_en.pdf APPLICABLE PV MODULE & PUMP PERFORMANCE SHOULD BE CAREFULLY CONSIDERED IN CONJUCTION WITH THE POOL PUMPING REQUIREMENTS AND OTHER IMPORTANT SITE CHARACTERISTICS. 02 SCALE: NTS PARCEL (PROPERTY APPRAISER DATA) SYSTEM: UNIRAC, INC. 1411 BROADWAY BOULEVARD NE ALBUQUERQUE NM 87102-1545 TELEPHONE: 505-242-6411 INSTALLATION LOCATION 11 SCALE: NTS ASCE 7 PRESSURE ZONE DIAGRAM 04 SCALE: NTS PV POWERED PUMP DATA SHEET 04 SCALE: NTS SYSTEM INSTALLATION DIAGRAM